IBM ServeRAID H1135 for IBM Flex System and BladeCenter...

56
IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products Installation and User’s Guide

Transcript of IBM ServeRAID H1135 for IBM Flex System and BladeCenter...

Page 1: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

IBM ServeRAID H1135for IBM Flex System and BladeCenter Products

Installation and User’s Guide

���

Page 2: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications
Page 3: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

IBM ServeRAID H1135for IBM Flex System and BladeCenter Products

Installation and User’s Guide

���

Page 4: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Note: Before using this information and the product it supports, read the general information in Appendix B, “Notices,” on page 33and see the Important Notices and Warranty Information documents that comes with the ServeRAID controller.

Second Edition (June 2012)

© Copyright IBM Corporation 2012.US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contractwith IBM Corp.

Page 5: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Safety

Before installing this product, read the Safety Information.

Antes de instalar este produto, leia as Informações de Segurança.

Læs sikkerhedsforskrifterne, før du installerer dette produkt.

Lees voordat u dit product installeert eerst de veiligheidsvoorschriften.

Ennen kuin asennat tämän tuotteen, lue turvaohjeet kohdasta Safety Information.

Avant d'installer ce produit, lisez les consignes de sécurité.

Vor der Installation dieses Produkts die Sicherheitshinweise lesen.

Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza.

Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet.

Antes de instalar este produto, leia as Informações sobre Segurança.

Antes de instalar este producto, lea la información de seguridad.

Läs säkerhetsinformationen innan du installerar den här produkten.

© Copyright IBM Corp. 2012 iii

Page 6: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Be sure to read all caution and danger statements in this document before youperform the procedures. Read any additional safety information that comes with theserver or optional device before you install the device.

Important:

Each caution and danger statement in this document is labeled with a number. Thisnumber is used to cross reference an English-language caution or dangerstatement with translated versions of the caution or danger statement in the SafetyInformation document.

For example, if a caution statement is labeled “Statement 1,” translations for thatcaution statement are in the Safety Information document under “Statement 1.”

Be sure to read all caution and danger statements in this document before youperform the procedures. Read any additional safety information that comes with theserver or optional device before you install the device.

iv IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 7: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Statement 1:

DANGER

Electrical current from power, telephone, and communication cables ishazardous.

To avoid a shock hazard:

v Do not connect or disconnect any cables or perform installation,maintenance, or reconfiguration of this product during an electricalstorm.

v Connect all power cords to a properly wired and grounded electricaloutlet.

v Connect to properly wired outlets any equipment that will be attached tothis product.

v When possible, use one hand only to connect or disconnect signalcables.

v Never turn on any equipment when there is evidence of fire, water, orstructural damage.

v Disconnect the attached power cords, telecommunications systems,networks, and modems before you open the device covers, unlessinstructed otherwise in the installation and configuration procedures.

v Connect and disconnect cables as described in the following table wheninstalling, moving, or opening covers on this product or attacheddevices.

To Connect: To Disconnect:

1. Turn everything OFF.

2. First, attach all cables to devices.

3. Attach signal cables to connectors.

4. Attach power cords to outlet.

5. Turn device ON.

1. Turn everything OFF.

2. First, remove power cords from outlet.

3. Remove signal cables from connectors.

4. Remove all cables from devices.

Statement 12

CAUTION:The following label indicates a hot surface nearby.

Safety v

Page 8: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Statement 21

CAUTION:Hazardous energy is present when the blade is connected to the powersource. Always replace the blade cover before installing the blade.

UL regulatory information

This device is for use only with Listed IBM® Flex System Enterprise Chassis.

vi IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 9: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Contents

Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii

Chapter 1. Introduction . . . . . . . . . . . . . . . . . . . . . . 1Related documentation . . . . . . . . . . . . . . . . . . . . . . 1The IBM Documentation CD . . . . . . . . . . . . . . . . . . . . 3

Hardware and software requirements . . . . . . . . . . . . . . . . 3Using the Documentation Browser . . . . . . . . . . . . . . . . . 3

Notices and statements . . . . . . . . . . . . . . . . . . . . . . 4ServeRAID controller features . . . . . . . . . . . . . . . . . . . . 5ServeRAID controller specifications . . . . . . . . . . . . . . . . . . 6

Functional specifications . . . . . . . . . . . . . . . . . . . . . 6Physical dimensions . . . . . . . . . . . . . . . . . . . . . . 6Electrical specifications . . . . . . . . . . . . . . . . . . . . . 6

Using the ServeRAID controller . . . . . . . . . . . . . . . . . . . 6Using the ServeRAID controller with a blade server . . . . . . . . . . . 6Using the ServeRAID controller with a compute node . . . . . . . . . . 7

Chapter 2. Installing and removing the ServeRAID controller . . . . . . . 9Handling the ServeRAID controller . . . . . . . . . . . . . . . . . . 9Installing the ServeRAID controller. . . . . . . . . . . . . . . . . . 10Removing the ServeRAID controller . . . . . . . . . . . . . . . . . 13

Chapter 3. Updating the firmware and installing device drivers. . . . . . 15Installing and updating the firmware . . . . . . . . . . . . . . . . . 15Installing the device drivers . . . . . . . . . . . . . . . . . . . . 15Supported operating systems . . . . . . . . . . . . . . . . . . . 16

Chapter 4. Configuring the ServeRAID controller . . . . . . . . . . . 17Configuration overview . . . . . . . . . . . . . . . . . . . . . . 17Using the LSI SAS2 MPT Controller Configuration Application . . . . . . . 17

Chapter 5. Parts listing . . . . . . . . . . . . . . . . . . . . . 23

Chapter 6. Solving problems . . . . . . . . . . . . . . . . . . . 25Hardware problems . . . . . . . . . . . . . . . . . . . . . . . 25Software problems . . . . . . . . . . . . . . . . . . . . . . . 26System-configuration problems . . . . . . . . . . . . . . . . . . . 26SAS device problems . . . . . . . . . . . . . . . . . . . . . . 26

Appendix A. Getting help and technical assistance . . . . . . . . . . 29Before you call . . . . . . . . . . . . . . . . . . . . . . . . . 29Using the documentation . . . . . . . . . . . . . . . . . . . . . 30Getting help and information from the World Wide Web . . . . . . . . . . 30Software service and support . . . . . . . . . . . . . . . . . . . 30Hardware service and support . . . . . . . . . . . . . . . . . . . 30IBM Taiwan product service . . . . . . . . . . . . . . . . . . . . 31

Appendix B. Notices . . . . . . . . . . . . . . . . . . . . . . 33Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . 33Important notes. . . . . . . . . . . . . . . . . . . . . . . . . 34Particulate contamination . . . . . . . . . . . . . . . . . . . . . 35Documentation format . . . . . . . . . . . . . . . . . . . . . . 35Telecommunication regulatory statement . . . . . . . . . . . . . . . 36

© Copyright IBM Corp. 2012 vii

Page 10: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Electronic emission notices . . . . . . . . . . . . . . . . . . . . 36Federal Communications Commission (FCC) statement . . . . . . . . . 36Industry Canada Class A emission compliance statement . . . . . . . . 36Avis de conformité à la réglementation d'Industrie Canada . . . . . . . . 36Australia and New Zealand Class A statement . . . . . . . . . . . . 36European Union EMC Directive conformance statement . . . . . . . . . 37Germany Class A statement . . . . . . . . . . . . . . . . . . . 37VCCI Class A statement . . . . . . . . . . . . . . . . . . . . 38Japan Electronics and Information Technology Industries Association (JEITA)

statement . . . . . . . . . . . . . . . . . . . . . . . . . 38Korea Communications Commission (KCC) statement . . . . . . . . . 38Russia Electromagnetic Interference (EMI) Class A statement. . . . . . . 39People's Republic of China Class A electronic emission statement . . . . . 39Taiwan Class A compliance statement . . . . . . . . . . . . . . . 39

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

viii IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 11: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Chapter 1. Introduction

The IBM ServeRAID H1135 controller enables you to use RAID technology tomanage hard disk drive configurations and integrate Serial Attached SCSI (SAS)technology into your storage infrastructure. You can install the optional IBMServeRAID H1135 controller in an IBM Flex System x220 Compute Node or an IBMBladeCenter® HS23E blade server. To determine if the ServeRAID H1135 controlleris compatible with your compute node or blade server, go to http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/.

The IBM ServeRAID H1135 controller has four ports for connection to SAS or SerialAdvanced Technology Attachment (SATA) devices and solid state drives (SSD).These four ports provide 6.0 Gbps SAS/SATA link rates, and they can manage twolocal hard disk drives (up to 6.0 Gbps SAS/SATA link rates) and two I/O-modules(up to 3.0 Gbps SAS link rates). The controller uses four full-duplex PCI Express(PCIe) lanes that provide host-side maximum transmission and reception in eachdirection of up to 5.0 GBps, which yields a total bandwidth of 10.0 Gbps for eachfull-duplex lane.

The IBM ServeRAID controller is based on the LSI SAS2004 RAID controller, and itsupports the following RAID configurations:

v RAID 0 striping

v RAID 1 mirroring

v RAID 1 enhanced mirroring (blade server only)

v RAID 10 mirroring and striping (blade server only)

This Installation and User's Guide contains information and instructions forinstalling, removing, updating, and configuring the ServeRAID controller. It alsoincludes instructions for performing basic troubleshooting tasks and solvingproblems with the ServeRAID controller. The most recent version of this Installationand User's Guide can be found at http://www-947.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5088601.

The ServeRAID controller comes with a one year limited warranty. You can obtainup-to-date information about the ServeRAID controllers and other IBM serverproducts at http://www.ibm.com/supportportal/. Additional information about theServeRAID controller might be available at http://www-03.ibm.com/systems/x/options/storage/raid/scsi_raid.html.

For service or assistance, see Appendix A, “Getting help and technical assistance,”on page 29.

Related documentation

In addition to this Installation and User's Guide, the following documentation isavailable for the ServeRAID controller:

v IBM SAS2 BIOS Configuration Utility User's Guide

This document is available at http://www-947.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5088601. It contains information about using the SAS2BIOS-based utility to configure the integrated RAID functions of the ServeRAIDH1135 controller.

© Copyright IBM Corp. 2012 1

Page 12: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

v IBM SAS2 Integrated RAID Configuration Utility User's Guide

This document is available at http://www-947.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5088601. It contains information about using the SAS2integrated RAID command-line utility to configure the integrated RAID functionsof the ServeRAID H1135 controller.

v IBM Flex System Installation and Service Guide for the compute node

Each type of compute node has a customized Installation and Service Guide.This document comes with the compute node and contains instructions forinstalling the ServeRAID controller, system board illustrations that show where toinstall the ServeRAID controller, and information to help diagnose and correctproblems that might occur.

v IBM Flex System Installation and Service Guide for the chassis

This document contains instructions for removing and installing nodes,information about the I/O module bay locations, and information to diagnose andcorrect problems that might occur.

v IBM BladeCenter Installation and User’s Guide for the blade server

Each type of blade server has a customized Installation and User’s Guide. Thisdocument comes with the blade server and contains specific instructions forinstalling the ServeRAID controller, system board illustrations that show where toinstall the ServeRAID controller, and information to help diagnose and correctproblems that might occur.

v IBM BladeCenter Installation and User’s Guide for the chassis

This document contains instructions for removing and installing blade servers,information about the I/O module bay locations, and information to diagnose andcorrect problems that might occur.

v IBM Environmental Notices and Users Guide

This multilingual document is provided in portable document format (PDF) on theIBM Documentation CD. It contains translated country-specific environmentalnotices for the ServeRAID H1135 controller.

v IBM Safety Information

This multilingual document is provided in PDF on the IBM Documentation CD. Itcontains translated caution and danger statements. Each caution and dangerstatement that appears in the documentation has a number that you can use tolocate the corresponding statement in your language in the IBM SafetyInformation document.

v IBM Warranty Information

This multilingual document comes with the ServeRAID H1135 controller andcontains information about the terms of the warranty.

v IBM Important Notices

This multilingual document comes with the controller, and it containscountry-specific notices that must ship with the ServeRAID H1135 controller inprinted format.

v Human Interface Infrastructure Configuration Application User Guide

This document is used to configure controllers, physical disks and virtual disks,and to perform additional configuration tasks in a pre-boot environment.

To obtain ServeRAID controller documentation for device drivers and other tools, goto http://www.ibm.com/systems/support/ and enter the search term ServeRAIDcontroller to list and access the applicable Web sites.

2 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 13: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

The IBM Documentation CDThe IBM Documentation CD contains documentation for the server in PortableDocument Format (PDF) and includes the IBM Documentation Browser to help youfind information quickly.

Hardware and software requirementsThe IBM Documentation CD requires the following minimum hardware andsoftware:v Microsoft Windows XP, Windows 2000, or Red Hat Linuxv 100 MHz microprocessorv 32 MB of RAMv Adobe Acrobat Reader 3.0 (or later) or xpdf, which comes with Linux operating

systems

Using the Documentation BrowserUse the Documentation Browser to browse the contents of the CD, read briefdescriptions of the documents, and view documents, using Adobe Acrobat Readeror xpdf. The Documentation Browser automatically detects the regional settings inyour server and displays the documents in the language for that region (ifavailable). If a document is not available in the language for that region, theEnglish-language version is displayed.

Use one of the following procedures to start the Documentation Browser:v If Autostart is enabled, insert the CD into the CD or DVD drive. The

Documentation Browser starts automatically.v If Autostart is disabled or is not enabled for all users, use one of the following

procedures:– If you are using a Windows operating system, insert the CD into the CD or

DVD drive and click Start → Run. In the Open field, typee:\win32.bat

where e is the drive letter of the CD or DVD drive, and click OK.– If you are using Red Hat Linux, insert the CD into the CD or DVD drive; then,

run the following command from the /mnt/cdrom directory:sh runlinux.sh

Select the server from the Product menu. The Available Topics list displays all thedocuments for the server. Some documents might be in folders. A plus sign (+)indicates each folder or document that has additional documents under it. Click theplus sign to display the additional documents.

When you select a document, a description of the document is displayed underTopic Description. To select more than one document, press and hold the Ctrl keywhile you select the documents. Click View Book to view the selected document ordocuments in Acrobat Reader or xpdf. If you selected more than one document, allthe selected documents are opened in Acrobat Reader or xpdf.

To search all the documents, type a word or word string in the Search field andclick Search. The documents in which the word or word string appears are listed inorder of the most occurrences. Click a document to view it, and press Ctrl+F to usethe Acrobat search function, or press Alt+F to use the xpdf search function withinthe document.

Click Help for detailed information about using the Documentation Browser.

Chapter 1. Introduction 3

Page 14: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Notices and statementsThe caution and danger statements in this document are also in the multilingualSafety Information document, which is on the IBM Documentation CD. Eachstatement is numbered for reference to the corresponding statement in the SafetyInformation document.

The following notices and statements are used in this document:

v Note: These notices provide important tips, guidance, or advice.

v Important: These notices provide information or advice that might help you avoidinconvenient or problem situations.

v Attention: These notices indicate possible damage to programs, devices, ordata. An attention notice is placed just before the instruction or situation in whichdamage might occur.

v Caution: These statements indicate situations that can be potentially hazardousto you. A caution statement is placed just before the description of a potentiallyhazardous procedure step or situation.

v Danger: These statements indicate situations that can be potentially lethal orhazardous to you. A danger statement is placed just before the description of apotentially lethal or hazardous procedure step or situation.

4 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 15: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

ServeRAID controller featuresThe IBM ServeRAID H1135 controller is based on the LSI SAS2004 RAIDcontroller, and it includes the following features:

v Four SAS/SATA ports for SAS, SATA, and SSD devices.

Note: The mixing of SAS and SATA in the same integrated volume is notsupported.

v Four full-duplex PCIe lanes that provide host-side maximum transmission andreception in each direction of up to 5.0 GBps, which yields a total bandwidth of10.0 Gbps for each full-duplex lane.

v Support for RAID 0, 1, 1E, and 10 configurations.

v Support for hot-swap SAS and SATA devices.

v Support for drive sizes greater than 2 TB for RAID 0, 1E, and 10 (not RAID 1)configurations.

v Support for up to two integrated volumes.

v A fixed stripe size of 64 KB.

v Provides compliance with Disk Data Format (DDF).

v Support for S.M.A.R.T.

v Support for dedicated and global hot spare hard disk drives.

v Support for non-disk devices.

v Support for mixed capacity physical disks.

v Support for Direct I/O.

v Support for non-RAID functionality.

v Support for up to 10 disks per integrated RAID volume, with one or two volumeson the ServeRAID controller. (The ServeRAID controller can support 14 volumedrives, including one or two hot spare disks.)

v Support for integrated mirroring volumes (RAID 1).

v Support for online capacity expansion for RAID 1 volumes.

v Support for booting from any kind of integrated RAID volume.

v The ability to operate without special operating system-specific software.

v High reliability and data integrity, with:

– Nonvolatile write journaling.

– Physical disks in a volume that are not visible to the operating system or toapplication software.

v Low host CPU and PCI bus utilization.

v Processing power that uses the LSI Fusion-MPT architecture:

– Shared-memory architecture minimizes external memory requests.

– Device hardware and firmware contain the functionality.

Additional information about the ServeRAID controller is available athttp://www-03.ibm.com/systems/x/options/storage/raid/scsi_raid.html.

Chapter 1. Introduction 5

Page 16: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

ServeRAID controller specificationsThe following sections provide the specifications for the IBM ServeRAID H1135controller.

Functional specificationsTable 1. ServeRAID H1135 controller specifications

Type Specification

RAID levels v 0 and 1

v 1E and 10 (blade server)

Number of ports v Two internal SAS ports to connect to thelocal drives

v Two external ports to support optionalexternal drives or other external devicesthat are connected to an externalexpansion unit or enclosure (blade server)

Data transfer rate v Up to 6 Gbps per port

v There is no 6 Gbps SAS switch; therefore,the maximum speed for external devicesis 3 Gbps (blade server)

Cache functions Write-back, write-through, and direct I/O

Multiple Virtual Disks or logical arrayssupported

64

Architecture LSI Fusion-MPT

Physical dimensionsThe ServeRAID controller is designed in the CIOv form factor with physicaldimensions of 53 mm (2.1 in.) x 82 mm (3.2 in.). The PCI Express x4 connection ismade through the CIOv connector. The ServeRAID controller supports SAS/SATAand SSD connections through the CIOv connector.

Electrical specificationsThe ServeRAID controller is powered from the CIOv +5 V and +3.3 V power rails.The integrated +1.0 V and +1.8 V are regulated from the +5 V and +3.3 V railsthrough switching regulators. The ServeRAID controller uses +1.0 V, +1.8 V and+3.3 V; all other components use +3.3 V. The maximum power requirement for theServeRAID controller under normal operation is 10 watts.

Using the ServeRAID controllerThe following sections provide basic information about using the IBM ServeRAIDH1135 controller with an IBM BladeCenter blade server or IBM Flex Systemcompute node.

Using the ServeRAID controller with a blade serverThe system board in the IBM blade server enables the ServeRAID controller totransfer data to and from two local hard disk drives (up to 6.0 Gbps SAS/SATA linkrates) and two SAS I/O-modules (up to 3.0 Gbps SAS link rates) in I/O-modulebays 3 and 4 of the BladeCenter unit.

6 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 17: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

To support the system configuration, and optional external drives or other externaldevices that are connected to an external enclosure or expansion unit, the IBMBladeCenter SAS Connectivity Module or IBM BladeCenter S SAS RAID ControllerModule is installed in I/O-module bay 3 or both I/O-module bays 3 and 4 in theBladeCenter unit for communication with the ServeRAID controller.

To support the external hard disk drives in an external expansion unit or enclosure,the IBM System Storage® DS3000 expansion unit must be attached to the SASConnectivity Module, or the external hard disk drives must be installed in a DiskStorage Module in the applicable I/O-module bays in a BladeCenter S unit thatsupports the Disk Storage Module function. Custom zoning is required so that onlyone IBM System Storage DS3000 expansion unit is mapped to a blade server.

The maximum number of blade servers that you can connect to the BladeCenterunit varies according to the type of BladeCenter unit that you are using. Forexample, some BladeCenter units, such as the BladeCenter H unit (Type 8852 or7989), support a maximum of 14 blade servers, and other BladeCenter units, suchas the BladeCenter S unit (Type 8886), support a maximum of six blade servers.

The following illustration shows the interconnections among the ServeRAIDcontroller, components, and external devices.

Disk storage module 2(BladeCenter S chassis only)

Disk storage module 1(BladeCenter S chassis only)

Blade server 14

Blade server 2

Blade server 1

1 2

Local drives

BladeCenter chassis

1 2 3 4 5 6

1 2 3 4 5 6

SAS connectivitymodule

SAS connectivitymodule

1 2 3 4 5 6

7 8 9 10 11 12

ServeRAID-H1135Controller

1 2 3 4 5 6

7 8 9 10 11 12

External disk storage device

External disk storage device

Using the ServeRAID controller with a compute nodeThe system board in the IBM compute node enables the ServeRAID controller totransfer data to and from two local hard disk drives (up to 6.0 Gbps SAS/SATA linkrates).

Two of the four ports on the ServeRAID controller are wired to the compute node.The following illustration shows the interconnections between the ServeRAIDcontroller and internal components.

Chapter 1. Introduction 7

Page 18: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Compute node

ServeRAID-H1135Controller

Local drives

1 2

8 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 19: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Chapter 2. Installing and removing the ServeRAID controller

This chapter provides instructions for handling, installing, and removing the IBMServeRAID H1135 controller.

Handling the ServeRAID controller

Attention: Static electricity can damage the system and other electronic devices.To avoid damage, keep the ServeRAID controller in its static-protective packageuntil you are ready to install it.

To reduce the possibility of damage from electrostatic discharge, observe thefollowing precautions:

v Limit your movement. Movement can cause static electricity to build up aroundyou.

v The use of a grounding system is recommended but is not required. Forexample, wear an electrostatic-discharge wrist strap, if one is available.

v Handle the ServeRAID controller carefully, holding it by its edges or its frame.

v Do not touch solder joints, pins, or exposed circuitry.

v Do not leave the ServeRAID controller where others can handle and damage it.

v While the ServeRAID controller is still in its static-protective package, touch it toan unpainted metal part of the server for at least 2 seconds. This drains staticelectricity from the package and from your body.

v Remove the ServeRAID controller from its package and install it directly into thecompute node or blade server. If it is necessary to set down the ServeRAIDcontroller, put it back into its static-protective package. Do not place theServeRAID controller on the system cover or on a metal surface.

v Take additional care when you handle the ServeRAID controller during coldweather. Heating reduces indoor humidity and increases static electricity.

© Copyright IBM Corp. 2012 9

Page 20: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Installing the ServeRAID controller

Statement 1:

DANGER

Electrical current from power, telephone, and communication cables ishazardous.

To avoid a shock hazard:

v Do not connect or disconnect any cables or perform installation,maintenance, or reconfiguration of this product during an electricalstorm.

v Connect all power cords to a properly wired and grounded electricaloutlet.

v Connect to properly wired outlets any equipment that will be attached tothis product.

v When possible, use one hand only to connect or disconnect signalcables.

v Never turn on any equipment when there is evidence of fire, water, orstructural damage.

v Disconnect the attached power cords, telecommunications systems,networks, and modems before you open the device covers, unlessinstructed otherwise in the installation and configuration procedures.

v Connect and disconnect cables as described in the following table wheninstalling, moving, or opening covers on this product or attacheddevices.

To Connect: To Disconnect:

1. Turn everything OFF.

2. First, attach all cables to devices.

3. Attach signal cables to connectors.

4. Attach power cords to outlet.

5. Turn device ON.

1. Turn everything OFF.

2. First, remove power cords from outlet.

3. Remove signal cables from connectors.

4. Remove all cables from devices.

To install the IBM ServeRAID H1135 controller, complete the following steps:

1. If you have not already done so, read the safety information that begins onpage iii and “Handling the ServeRAID controller” on page 9.

2. If the compute node or blade server is installed, remove it. (For additionalinformation about removing the node or blade server, see the Installation andService Guide or the Installation and User's Guide that came with the computenode or blade server.)

3. Carefully place the compute node or blade server on a flat, static-protectivesurface.

10 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 21: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

4. Remove the compute node or blade server cover. (For additional informationabout removing the cover, see the Installation and Service Guide or theInstallation and User's Guide that came with the compute node or bladeserver.)

5. If an optional expansion unit is installed, remove the expansion unit. (Foradditional information about removing the expansion unit, see the Installationand User's Guide that came with the blade server).

6. Touch the static-protective package that contains the ServeRAID controller toany unpainted metal surface on any grounded rack component; then, removethe ServeRAID controller from the package.

The following illustration shows the ServeRAID controller.

ServeRAIDcontroller

7. Locate the connector for the ServeRAID controller on the compute node orblade server system board. See the Installation and Service Guide or theInstallation and User's Guide that came with the compute node or blade server.

8. Orient the connector on the ServeRAID controller with the connector on thesystem board; then, press the controller into the system board connector.

The following illustration shows the installation of the ServeRAID controller onthe compute node and blade server system boards.

H1135 ServeRAID card

9. Firmly press on the indicated locations to seat the ServeRAID controller.

Chapter 2. Installing and removing the ServeRAID controller 11

Page 22: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

10. If an I/O expansion adapter was removed, reinstall it, unless it was previouslyinstalled in the same connector in which the ServeRAID controller is nowinstalled. (For additional information about installing expansion adapters, seethe Installation and User's Guide that came with the blade server.)

11. Replace the compute node or blade server cover. (For more information, seethe Installation and Service Guide or the Installation and User's Guide thatcame with the compute node or blade server.)

12. Install and turn on the compute node or blade server. (For more information,see the Installation and Service Guide or the Installation and User's Guide thatcame with the compute node or blade server.)

13. Install the ServeRAID controller device driver. For additional information, seeChapter 3, “Updating the firmware and installing device drivers,” on page 15.

14. Make sure that the latest-level firmware is installed. For additional information,see Chapter 3, “Updating the firmware and installing device drivers,” on page15.

15. Configure the ServeRAID controller. For additional information, see Chapter 4,“Configuring the ServeRAID controller,” on page 17.

12 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 23: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Removing the ServeRAID controller

Statement 1:

DANGER

Electrical current from power, telephone, and communication cables ishazardous.

To avoid a shock hazard:

v Do not connect or disconnect any cables or perform installation,maintenance, or reconfiguration of this product during an electricalstorm.

v Connect all power cords to a properly wired and grounded electricaloutlet.

v Connect to properly wired outlets any equipment that will be attached tothis product.

v When possible, use one hand only to connect or disconnect signalcables.

v Never turn on any equipment when there is evidence of fire, water, orstructural damage.

v Disconnect the attached power cords, telecommunications systems,networks, and modems before you open the device covers, unlessinstructed otherwise in the installation and configuration procedures.

v Connect and disconnect cables as described in the following table wheninstalling, moving, or opening covers on this product or attacheddevices.

To Connect: To Disconnect:

1. Turn everything OFF.

2. First, attach all cables to devices.

3. Attach signal cables to connectors.

4. Attach power cords to outlet.

5. Turn device ON.

1. Turn everything OFF.

2. First, remove power cords from outlet.

3. Remove signal cables from connectors.

4. Remove all cables from devices.

The following illustration shows the ServeRAID controller.

ServeRAIDcontroller

To remove the IBM ServeRAID H1135 controller, complete the following steps:

1. If you have not already done so, read the safety information that begins onpage iii and “Handling the ServeRAID controller” on page 9.

Chapter 2. Installing and removing the ServeRAID controller 13

Page 24: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

2. If the compute node or blade server is installed, remove it. (For additionalinformation about removing the compute node or blade server, see theInstallation and Service Guide or the Installation and User's Guide that camewith the compute node or blade server.)

3. Carefully place the compute node or blade server on a flat, static-protectivesurface.

4. Remove the compute node or blade server cover. (For additional informationabout removing the cover, see the Installation and Service Guide or theInstallation and User's Guide that came with the compute node or blade server.)

5. Locate the connector that contains the ServeRAID controller on the computenode or blade server system board. See the Installation and Service Guide orthe Installation and User's Guide that came with the compute node or bladeserver.

6. Using your fingers, move the retaining clips away from the ServeRAIDcontroller; then, lift the ServeRAID controller out of the system board connector.

The following illustration shows the removal of the ServeRAID controller from thecompute node or blade server system boards.

H1135 ServeRAID card

Releasetabs

14 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 25: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Chapter 3. Updating the firmware and installing device drivers

This chapter contains general information about updating the controller firmwareand installing device drivers for the IBM ServeRAID H1135 controller.

After you install the ServeRAID controller, complete the following steps:

1. Make sure that the ServeRAID controller has the latest firmware. Periodicupdates are made available.

2. Before you install the device drivers and firmware, make sure that theappropriate devices have the latest firmware level. If these devices do not havethe latest firmware, update the firmware. For additional information, seehttp://www.ibm.com/systems/support/.

3. Install the operating system and device drivers. For additional information referto the Installation and Service Guide or the Installation and User's Guide thatcame with the compute node or blade server.

Notes:

v The operating systems vary and depend on the hardware and software that youare using.

v For the latest information about operating-system support, versions of devicedrivers, utilities, and documentation, see http://www.ibm.com/systems/support/.

Installing and updating the firmwareThe IBM ServeRAID H1135 controller is shipped with the latest level of firmwarethat was available at the time of manufacture. To find, install, and update thecontroller to the latest firmware, go to http://www.ibm.com/systems/support. TheServeRAID controller might have features that are not described in thedocumentation that comes with the ServeRAID controller. The documentation mightbe updated occasionally to include information about those features or technicalupdates might be available to provide additional information that is not included inthe system documentation. For additional information, see the Installation andService Guide or the Installation and User's Guide that came with the computenode or blade server.

Installing the device driversAfter you install the ServeRAID controller, you must install the device drivers foryour operating system. For a list of supported operating systems, see “Supportedoperating systems” on page 16.

To find, install, and update the latest device drivers, go to http://www.ibm.com/systems/support. Install the operating system and remaining device drivers byfollowing the instructions that are provided in the Installation and Service Guide orthe Installation and User's Guide that came with the compute node or blade server.

© Copyright IBM Corp. 2012 15

Page 26: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Supported operating systemsThe following operating systems are supported with the ServeRAID controllerwhen it is installed in a compute node:

v Microsoft Windows Server 2008 R2 SP1

v Microsoft Windows Server 2008, Database (x64) Edition SP2

v Microsoft Windows Server 2008, Enterprise (x64) Edition

v Microsoft Windows Server 2008 HPC Edition

v Microsoft Windows Server 2008 Standard (x64) Edition

v Microsoft Windows Server 2008 Web (x64) Edition

v Windows Small Business Server 2008 Premium Edition

v Windows Small Business Server 2008 Standard Edition

v Red Hat Enterprise Linux V5.7 Server (x64) Edition

v Red Hat Enterprise Linux V5.7 Server with Xen (x64) Edition

v Red Hat Enterprise Linux V6.2 Server (x64) Edition

v SUSE Linux Enterprise Server V10 (AMD64 and EM64T) SP4

v SUSE Linux Enterprise Server V11 (AMD64 and EM64T) SP2

v SUSE Linux Enterprise Server V11 with Xen for AMD64/EM64T SP2

v VMware ESX Server V4.1 Update 2

v VMware ESXi Server V4.1 Update 2

v VMware vSphere 5

The following operating systems are supported with the ServeRAID controllerwhen it is installed in a blade server:

v Microsoft Windows Server 2008 R2 SP1

v Microsoft Windows Server 2008, Database (x64) Edition SP2

v Microsoft Windows Server 2008, Enterprise (x64) Edition

v Microsoft Windows Server 2008 HPC Edition

v Microsoft Windows Server 2008 Standard (x64) Edition

v Microsoft Windows Server 2008 Web (x64) Edition

v Red Hat Enterprise Linux V5.7 Server (x64) Edition

v Red Hat Enterprise Linux V5.7 Server with Xen (x64) Edition

v Red Hat Enterprise Linux V6.2 Server (x86) Edition

v Red Hat Enterprise Linux V6.2 Server (x64) Edition

v SUSE Linux Enterprise Server V10 (AMD64 and EM64T) SP4

v SUSE Linux Enterprise Server V10 with Xen (AMD64 and EM64T) SP4

v SUSE Linux Enterprise Server V11 (x86) SP2

v SUSE Linux Enterprise Server V11 (AMD64 and EM64T) SP2

v SUSE Linux Enterprise Server V11 with Xen (AMD64 and EM64T) SP2

v VMware ESX Server V4.1 Update 2

v VMware ESXi Server V4.1 Update 2

v VMware vSphere 5

16 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 27: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Chapter 4. Configuring the ServeRAID controller

This chapter provides information about configuring the IBM ServeRAID H1135controller.

Configuration overviewBefore you begin, make sure that you know the following information about yourcompute node or blade server configuration:

v The number of drives that the ServeRAID controller can use.

v The purpose of the drive group.

v The availability of spare drives.

v If you are configuring the controller in a blade server, also review the informationthat shows the interconnections among the ServeRAID controller, otherBladeCenter components, and external devices.

See the documentation that came with your compute node or blade server, chassis,and the following documents for more detailed information about using theServeRAID configuration utilities:

v IBM SAS2 BIOS Configuration Utility Users Guide

This document is available at http://www-947.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5088601. It contains information about using the SAS2BIOS-based utility to configure the integrated RAID functions of the ServeRAIDH1135 controller.

v IBM SAS2 Integrated RAID Configuration Utility Users Guide

This document is available at http://www-947.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5088601. It contains information about using the SAS2integrated RAID command-line utility to configure the integrated RAID functionsof the ServeRAID H1135 controller.

v Human Interface Infrastructure Configuration Application User Guide

This document is available at http://www-947.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5088601. It contains information about configuringcontrollers, physical disks and virtual disks.

Using the LSI SAS2 MPT Controller Configuration ApplicationYou can use the LSI SAS2 MPT Controller Configuration Application to configurethe IBM ServeRAID H1135 controller and the storage devices in a pre-bootenvironment.

Note: When you configure a RAID solution, the hard disk drives must use thesame type of interface.

To start the application, complete the following steps:

1. Connect a keyboard, monitor, and mouse to the console breakout cable; then,connect the console breakout cable to the compute node or blade server.

2. Turn on the compute node or blade server.

3. When the prompt <Press F1> is displayed, press F1.

4. Select Systems Settings from the System Configuration and Boot Managementwindow.

© Copyright IBM Corp. 2012 17

Page 28: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

The System Configuration and Boot Management window is displayed in thefollowing illustration.

5. Select Storage from the System Settings window.

The System Settings window is displayed in the following illustration.

6. From the Storage window, use the arrow keys to select the controller you wantto configure; then, press Enter.

The next two illustrations display the Storage window and resulting ControllerConfiguration window.

18 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 29: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

7. Press Enter to continue, the Configuration Options window appears.

Examples of the Configuration Options window are displayed in the followingtwo illustrations.

Chapter 4. Configuring the ServeRAID controller 19

Page 30: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

8. Select a menu option to continue with your management and configurationtasks.

a. Select Controller Management, to view and manage controller properties,create volumes, import or delete foreign volumes and save or clearcontroller events.

The Controller Management window is displayed in the following illustration.

20 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 31: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

b. Select Physical Disk Management to manage all disks.

The Physical Disk Management window is displayed in the followingillustration.

For additional instructions about using this application, see the Human InterfaceInfrastructure Configuration Application User Guide. This document is available athttp://www-947.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5088601.

Chapter 4. Configuring the ServeRAID controller 21

Page 32: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

22 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 33: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Chapter 5. Parts listing

The ServeRAID controller comes with a one-year limited warranty. For moreinformation about the terms of the warranty and getting service and assistance, seethe IBM Warranty Information document.

The replaceable components in Table 2 are Tier 1 customer replaceable units(CRU). Replacement of a Tier 1 CRU is your responsibility. If IBM installs a Tier 1CRU at your request, you will be charged for the installation.

Table 2. Customer replaceable components and corresponding CRU identifiers

Description CRU part number (Tier 1)

ServeRAID H1135 Controller v 90Y4735

© Copyright IBM Corp. 2012 23

Page 34: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

24 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 35: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Chapter 6. Solving problems

This chapter provides basic troubleshooting information to help you solve someproblems that might occur while you are setting up the ServeRAID controller. Formore information about troubleshooting the ServeRAID controller, go tohttp://www.ibm.com/systems/support/.

For your compute node or blade server, make sure that you are using the latestversions of device drivers, utilities, firmware code, baseboard managementcontroller (BMC), and BIOS or UEFI code. If necessary, install the latest versions ofdevice drivers, utilities, firmware code, and BIOS or UEFI code.

To download the most recent device drivers, utilities, firmware updates, BIOS orUEFI code updates, and expansion-adapter boot code updates, go tohttp://www.ibm.com/systems/support/. For the latest information about upgrading thedevice drivers, firmware, and BIOS or UEFI code go to http://www.ibm.com/systems/support/. The instructions are in the documentation that comes with theupdates.

If you cannot locate and correct a problem by using the information in this chapter,see Appendix A, “Getting help and technical assistance,” on page 29.

Hardware problemsTo determine whether an installation problem is caused by the hardware, performthe following tasks:

v Before you begin your system hardware installation activities, make sure thatyou have all the hardware devices that are required to support the compute nodeor blade server configuration that you plan to use. Include the followingpreinstallation requirements. For additional information, see the documentationthat comes with the devices that you are using.

– If the system configuration includes external devices, certain requirementsapply. For additional information, see “Using the ServeRAID controller” onpage 6.

– If the system configuration includes disk arrays, certain requirements apply tothe ServeRAID controller, For additional information, see Chapter 4,“Configuring the ServeRAID controller,” on page 17.

v Before you install the ServeRAID controller make sure that you are using acompute node or blade server that supports the ServeRAID controller.

v Make sure that the I/O modules are compatible with the target expansionadapters that you want to communicate with these I/O modules.

v Make sure that the ServeRAID controller is correctly installed in the computenode or blade server. For additional information, see the Installation and ServiceGuide or the Installation and User's Guide that comes with the compute node orblade server.

v Make sure that the compute node or blade server is correctly installed.

v Make sure that the utility device-driver parameters are correct.

v Make sure that all peripheral devices are correctly connected to the I/O modules,turned on, and operating correctly.

v For the blade server, make sure that an I/O module that supports SAS operationis correctly installed in I/O-module bay 3 or both I/O-module bays 3 and 4 of thesystem unit.

© Copyright IBM Corp. 2012 25

Page 36: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Software problemsTo determine whether the installation problem is caused by the software, performthe following tasks:

v Make sure that the correct device drivers are installed. To download or getinformation about the latest supported device drivers, utilities, anddocumentation, see http://www.ibm.com/systems/support/. Also see theInstallation and Service Guide or the Installation and User's Guide that came withthe compute node or blade server.

v Make sure that the BIOS or UEFI functional firmware and boot code in theServeRAID controller are at the latest levels.

v Make sure that you are using the correct expansion-adapter NVRAM settings forthe storage area network (SAN) and operating system.

System-configuration problemsTo determine whether the installation problem is caused by the systemconfiguration, perform the following tasks:

v Make sure that the I/O modules that support SAS operation are correctlyconfigured.

v Make sure that all compute node or blade server components are correctlyconfigured.

v Make sure that all parameters, internal devices, and external devices have beenenabled, where required. These devices might include the I/O module and itsinternal and external ports.

For additional information, see the documentation that comes with the managementmodule and the applicable utility programs and devices.

If you still have a system-configuration problem, you must determine whether thesystem board requires a special configuration. To determine whether the systemboard requires a special configuration, see the documentation that comes with yourcompute node or blade server, or contact your IBM technical-support representative.

Note: For additional information about configuration requirements, see thedocumentation that comes with your compute node or blade server.

SAS device problemsTo determine whether your problem is caused by an attached SAS device, performthe following tasks:

v For the blade server, make sure that an I/O module that supports SAS operationis correctly installed in one or more of the following I/O-module bay combinationsin the system unit:

– In I/O-module bay 3 of the BladeCenter unit

– In both I/O-module bays 3 and 4 of the system unit

Note: Installing a second I/O module in the BladeCenter unit provides a backupI/O module in case one I/O module fails. Both I/O modules must be of the sametype, in the previously specified I/O-module bay combinations in the BladeCenterunit.

v Make sure that the compute node or blade server is turned on.

26 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 37: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

v Make sure that the compute node or blade server ServeRAID controller settingsare the correct values:

– See the troubleshooting section of the documentation that comes with theapplicable device driver.

v Make sure that all parameters, internal devices, and external devices have beenenabled, where required. These devices might include the I/O module and itsinternal and external ports.

For additional information, see the documentation that comes with themanagement module and the applicable utility programs and devices.

For additional information, see the documentation that comes with the managementmodule and the applicable utility programs and devices.

Chapter 6. Solving problems 27

Page 38: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

28 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 39: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Appendix A. Getting help and technical assistance

If you need help, service, or technical assistance or just want more informationabout IBM products, you will find a wide variety of sources available from IBM toassist you. Use this information to obtain additional information about IBM and IBMproducts, determine what to do if you experience a problem with your IBM systemor optional device, and determine whom to call for service, if it is necessary.

Before you callBefore you call, make sure that you have taken these steps to try to solve theproblem yourself:

v Check all cables to make sure that they are connected.

v Check the power switches to make sure that the system and any optionaldevices are turned on.

v Check for updated firmware and operating-system device drivers for your IBMproduct. The IBM Warranty terms and conditions state that you, the owner of theIBM product, are responsible for maintaining and updating all software andfirmware for the product (unless it is covered by an additional maintenancecontract). Your IBM service technician will request that you upgrade yoursoftware and firmware if the problem has a documented solution within asoftware upgrade.

v If you have installed new hardware or software in your environment, checkhttp://www.ibm.com/systems/info/x86servers/serverproven/compat/us/ to makesure that the hardware and software is supported by your IBM product.

v Go to http://www.ibm.com/supportportal/ to check for information to help yousolve the problem.

v Gather the following information to provide to IBM Support. This data will helpIBM Support quickly provide a solution to your problem and ensure that youreceive the level of service for which you might have contracted.

– Hardware and Software Maintenance agreement contract numbers, ifapplicable

– Machine type number (IBM 4-digit machine identifier)

– Model number

– Serial number

– Current system UEFI and firmware levels

– Other pertinent information such as error messages and logs

v Go to http://www.ibm.com/support/entry/portal/Open_service_request/ to submitan Electronic Service Request. Submitting an Electronic Service Request willstart the process of determining a solution to your problem by making thepertinent information available to IBM Support quickly and efficiently. IBM servicetechnicians can start working on your solution as soon as you have completedand submitted an Electronic Service Request.

You can solve many problems without outside assistance by following thetroubleshooting procedures that IBM provides in the online help or in thedocumentation that is provided with your IBM product. The documentation thatcomes with IBM systems also describes the diagnostic tests that you can perform.Most systems, operating systems, and programs come with documentation that

© Copyright IBM Corp. 2012 29

Page 40: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

contains troubleshooting procedures and explanations of error messages and errorcodes. If you suspect a software problem, see the documentation for the operatingsystem or program.

Using the documentationInformation about your IBM system and preinstalled software, if any, or optionaldevice is available in the documentation that comes with the product. Thatdocumentation can include printed documents, online documents, readme files, andhelp files. See the troubleshooting information in your system documentation forinstructions for using the diagnostic programs. The troubleshooting information orthe diagnostic programs might tell you that you need additional or updated devicedrivers or other software. IBM maintains pages on the World Wide Web where youcan get the latest technical information and download device drivers and updates.To access these pages, go to http://www.ibm.com/supportportal/. Also, somedocuments are available through the IBM Publications Center athttp://www.ibm.com/shop/publications/order/.

Getting help and information from the World Wide WebOn the World Wide Web, up-to-date information about IBM systems, optionaldevices, services, and support is available at http://www.ibm.com/supportportal/.The address for IBM System x® information is http://www.ibm.com/systems/x/. Theaddress for IBM BladeCenter information is http://www.ibm.com/systems/bladecenter/. The address for IBM IntelliStation® information ishttp://www.ibm.com/systems/intellistation/.

Software service and supportThrough IBM Support Line, you can get telephone assistance, for a fee, with usage,configuration, and software problems with your IBM products. For information aboutwhich products are supported by Support Line in your country or region, seehttp://www.ibm.com/services/supline/products/.

For more information about Support Line and other IBM services, seehttp://www.ibm.com/services/, or see http://www.ibm.com/planetwide/ for supporttelephone numbers. In the U.S. and Canada, call 1-800-IBM-SERV(1-800-426-7378).

Hardware service and supportYou can receive hardware service through your IBM reseller or IBM Services. Tolocate a reseller authorized by IBM to provide warranty service, go tohttp://www.ibm.com/partnerworld/ and click Find Business Partners on the rightside of the page. For IBM support telephone numbers, see http://www.ibm.com/planetwide/. In the U.S. and Canada, call 1-800-IBM-SERV (1-800-426-7378).

In the U.S. and Canada, hardware service and support is available 24 hours a day,7 days a week. In the U.K., these services are available Monday through Friday,from 9 a.m. to 6 p.m.

30 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 41: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

IBM Taiwan product service

IBM Taiwan product service contact information:IBM Taiwan Corporation3F, No 7, Song Ren Rd.Taipei, TaiwanTelephone: 0800-016-888

Appendix A. Getting help and technical assistance 31

Page 42: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

32 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 43: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Appendix B. Notices

This information was developed for products and services offered in the U.S.A.

IBM may not offer the products, services, or features discussed in this document inother countries. Consult your local IBM representative for information on theproducts and services currently available in your area. Any reference to an IBMproduct, program, or service is not intended to state or imply that only that IBMproduct, program, or service may be used. Any functionally equivalent product,program, or service that does not infringe any IBM intellectual property right may beused instead. However, it is the user's responsibility to evaluate and verify theoperation of any non-IBM product, program, or service.

IBM may have patents or pending patent applications covering subject matterdescribed in this document. The furnishing of this document does not give you anylicense to these patents. You can send license inquiries, in writing, to:

IBM Director of LicensingIBM CorporationNorth Castle DriveArmonk, NY 10504-1785U.S.A.

INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THISPUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSOR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIESOF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR APARTICULAR PURPOSE. Some states do not allow disclaimer of express orimplied warranties in certain transactions, therefore, this statement may not apply toyou.

This information could include technical inaccuracies or typographical errors.Changes are periodically made to the information herein; these changes will beincorporated in new editions of the publication. IBM may make improvements and/orchanges in the product(s) and/or the program(s) described in this publication at anytime without notice.

Any references in this information to non-IBM websites are provided forconvenience only and do not in any manner serve as an endorsement of thosewebsites. The materials at those websites are not part of the materials for this IBMproduct, and use of those websites is at your own risk.

IBM may use or distribute any of the information you supply in any way it believesappropriate without incurring any obligation to you.

TrademarksIBM, the IBM logo, and ibm.com are trademarks of International Business MachinesCorp., registered in many jurisdictions worldwide. Other product and service namesmight be trademarks of IBM or other companies. A current list of IBM trademarks isavailable on the web at “Copyright and trademark information” athttp://www.ibm.com/legal/copytrade.shtml.

Adobe and PostScript are either registered trademarks or trademarks of AdobeSystems Incorporated in the United States and/or other countries.

© Copyright IBM Corp. 2012 33

Page 44: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Cell Broadband Engine is a trademark of Sony Computer Entertainment, Inc., in theUnited States, other countries, or both and is used under license therefrom.

Intel, Intel Xeon, Itanium, and Pentium are trademarks or registered trademarks ofIntel Corporation or its subsidiaries in the United States and other countries.

Java and all Java-based trademarks and logos are trademarks or registeredtrademarks of Oracle and/or its affiliates.

Linux is a registered trademark of Linus Torvalds in the United States, othercountries, or both.

Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation inthe United States, other countries, or both.

UNIX is a registered trademark of The Open Group in the United States and othercountries.

Important notesThis product is not intended to be connected directly or indirectly by any meanswhatsoever to interfaces of public telecommunications networks, nor is it intendedto be used in a public services network.

Processor speed indicates the internal clock speed of the microprocessor; otherfactors also affect application performance.

CD or DVD drive speed is the variable read rate. Actual speeds vary and are oftenless than the possible maximum.

When referring to processor storage, real and virtual storage, or channel volume,KB stands for 1024 bytes, MB stands for 1,048,576 bytes, and GB stands for1,073,741,824 bytes.

When referring to hard disk drive capacity or communications volume, MB standsfor 1,000,000 bytes, and GB stands for 1,000,000,000 bytes. Total user-accessiblecapacity can vary depending on operating environments.

Maximum internal hard disk drive capacities assume the replacement of anystandard hard disk drives and population of all hard disk drive bays with the largestcurrently supported drives that are available from IBM.

Maximum memory might require replacement of the standard memory with anoptional memory module.

IBM makes no representation or warranties regarding non-IBM products andservices that are ServerProven®, including but not limited to the implied warrantiesof merchantability and fitness for a particular purpose. These products are offeredand warranted solely by third parties.

IBM makes no representations or warranties with respect to non-IBM products.Support (if any) for the non-IBM products is provided by the third party, not IBM.

Some software might differ from its retail version (if available) and might not includeuser manuals or all program functionality.

34 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 45: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Particulate contaminationAttention: Airborne particulates (including metal flakes or particles) and reactivegases acting alone or in combination with other environmental factors such ashumidity or temperature might pose a risk to the device that is described in thisdocument. Risks that are posed by the presence of excessive particulate levels orconcentrations of harmful gases include damage that might cause the device tomalfunction or cease functioning altogether. This specification sets forth limits forparticulates and gases that are intended to avoid such damage. The limits must notbe viewed or used as definitive limits, because numerous other factors, such astemperature or moisture content of the air, can influence the impact of particulatesor environmental corrosives and gaseous contaminant transfer. In the absence ofspecific limits that are set forth in this document, you must implement practices thatmaintain particulate and gas levels that are consistent with the protection of humanhealth and safety. If IBM determines that the levels of particulates or gases in yourenvironment have caused damage to the device, IBM may condition provision ofrepair or replacement of devices or parts on implementation of appropriate remedialmeasures to mitigate such environmental contamination. Implementation of suchremedial measures is a customer responsibility.

Table 3. Limits for particulates and gases

Contaminant Limits

Particulate v The room air must be continuously filtered with 40% atmospheric dustspot efficiency (MERV 9) according to ASHRAE Standard 52.21.

v Air that enters a data center must be filtered to 99.97% efficiency orgreater, using high-efficiency particulate air (HEPA) filters that meetMIL-STD-282.

v The deliquescent relative humidity of the particulate contaminationmust be more than 60%2.

v The room must be free of conductive contamination such as zincwhiskers.

Gaseous v Copper: Class G1 as per ANSI/ISA 71.04-19853

v Silver: Corrosion rate of less than 300 Å in 30 days1 ASHRAE 52.2-2008 - Method of Testing General Ventilation Air-Cleaning Devices forRemoval Efficiency by Particle Size. Atlanta: American Society of Heating, Refrigerating andAir-Conditioning Engineers, Inc.

2 The deliquescent relative humidity of particulate contamination is the relative humidity atwhich the dust absorbs enough water to become wet and promote ionic conduction.

3 ANSI/ISA-71.04-1985. Environmental conditions for process measurement and controlsystems: Airborne contaminants. Instrument Society of America, Research Triangle Park,North Carolina, U.S.A.

Documentation formatThe publications for this product are in Adobe Portable Document Format (PDF)and should be compliant with accessibility standards. If you experience difficultieswhen you use the PDF files and want to request a web-based format or accessiblePDF document for a publication, direct your mail to the following address:

Information DevelopmentIBM Corporation205/A0153039 E. Cornwallis RoadP.O. Box 12195Research Triangle Park, North Carolina 27709-2195

Appendix B. Notices 35

Page 46: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

U.S.A.

In the request, be sure to include the publication part number and title.

When you send information to IBM, you grant IBM a nonexclusive right to use ordistribute the information in any way it believes appropriate without incurring anyobligation to you.

Telecommunication regulatory statementThis product is not intended to be connected directly or indirectly by any meanswhatsoever to interfaces of public telecommunications networks, nor is it intendedto be used in a public services network.

Electronic emission noticesWhen you attach a monitor to the equipment, you must use the designated monitorcable and any interference suppression devices that are supplied with the monitor.

Federal Communications Commission (FCC) statementNote: This equipment has been tested and found to comply with the limits for aClass A digital device, pursuant to Part 15 of the FCC Rules. These limits aredesigned to provide reasonable protection against harmful interference when theequipment is operated in a commercial environment. This equipment generates,uses, and can radiate radio frequency energy and, if not installed and used inaccordance with the instruction manual, may cause harmful interference to radiocommunications. Operation of this equipment in a residential area is likely to causeharmful interference, in which case the user will be required to correct theinterference at his own expense.

Properly shielded and grounded cables and connectors must be used in order tomeet FCC emission limits. IBM is not responsible for any radio or televisioninterference caused by using other than recommended cables and connectors or byunauthorized changes or modifications to this equipment. Unauthorized changes ormodifications could void the user's authority to operate the equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to thefollowing two conditions: (1) this device may not cause harmful interference, and (2)this device must accept any interference received, including interference that maycause undesired operation.

Industry Canada Class A emission compliance statementThis Class A digital apparatus complies with Canadian ICES-003.

Avis de conformité à la réglementation d'Industrie CanadaCet appareil numérique de la classe A est conforme à la norme NMB-003 duCanada.

Australia and New Zealand Class A statementAttention: This is a Class A product. In a domestic environment this product maycause radio interference in which case the user may be required to take adequatemeasures.

36 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 47: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

European Union EMC Directive conformance statementThis product is in conformity with the protection requirements of EU CouncilDirective 2004/108/EC on the approximation of the laws of the Member Statesrelating to electromagnetic compatibility. IBM cannot accept responsibility for anyfailure to satisfy the protection requirements resulting from a nonrecommendedmodification of the product, including the fitting of non-IBM option cards.

Attention: This is an EN 55022 Class A product. In a domestic environment thisproduct may cause radio interference in which case the user may be required totake adequate measures.

Responsible manufacturer:International Business Machines Corp.New Orchard RoadArmonk, New York 10504914-499-1900

European Community contact:IBM Deutschland GmbHTechnical Regulations, Department M372IBM-Allee 1, 71139 Ehningen, GermanyTelephone: +49 7032 15 2941Email: [email protected]

Germany Class A statementDeutschsprachiger EU Hinweis:

Hinweis für Geräte der Klasse A EU-Richtlinie zur ElektromagnetischenVerträglichkeit

Dieses Produkt entspricht den Schutzanforderungen der EU-Richtlinie 2004/108/EGzur Angleichung der Rechtsvorschriften über die elektromagnetische Verträglichkeitin den EU-Mitgliedsstaaten und hält die Grenzwerte der EN 55022 Klasse A ein.

Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zuinstallieren und zu betreiben. Des Weiteren dürfen auch nur von der IBMempfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung fürdie Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung derIBM verändert bzw. wenn Erweiterungskomponenten von Fremdherstellern ohneEmpfehlung der IBM gesteckt/eingebaut werden.

EN 55022 Klasse A Geräte müssen mit folgendem Warnhinweis versehen werden:“Warnung: Dieses ist eine Einrichtung der Klasse A. Diese Einrichtung kann imWohnbereich Funk-Störungen verursachen; in diesem Fall kann vom Betreiberverlangt werden, angemessene Maßnahmen zu ergreifen und dafür aufzukommen.”

Deutschland: Einhaltung des Gesetzes über dieelektromagnetische Verträglichkeit von GerätenDieses Produkt entspricht dem “Gesetz über die elektromagnetische Verträglichkeitvon Geräten (EMVG)”. Dies ist die Umsetzung der EU-Richtlinie 2004/108/EG inder Bundesrepublik Deutschland.

Appendix B. Notices 37

Page 48: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Zulassungsbescheinigung laut dem Deutschen Gesetz über dieelektromagnetische Verträglichkeit von Geräten (EMVG) (bzw. derEMC EG Richtlinie 2004/108/EG) für Geräte der Klasse ADieses Gerät ist berechtigt, in Übereinstimmung mit dem Deutschen EMVG dasEG-Konformitätszeichen - CE - zu führen.

Verantwortlich für die Einhaltung der EMV Vorschriften ist der Hersteller:International Business Machines Corp.New Orchard RoadArmonk, New York 10504914-499-1900

Der verantwortliche Ansprechpartner des Herstellers in der EU ist:IBM Deutschland GmbHTechnical Regulations, Abteilung M372IBM-Allee 1, 71139 Ehningen, GermanyTelephone: +49 7032 15 2941Email: [email protected]

Generelle Informationen:

Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022Klasse A.

VCCI Class A statement

This is a Class A product based on the standard of the Voluntary Control Council forInterference (VCCI). If this equipment is used in a domestic environment, radiointerference may occur, in which case the user may be required to take correctiveactions.

Japan Electronics and Information Technology Industries Association(JEITA) statement

Japanese Electronics and Information Technology Industries Association (JEITA)Confirmed Harmonics Guideline (products less than or equal to 20 A per phase)

Korea Communications Commission (KCC) statement

This is electromagnetic wave compatibility equipment for business (Type A). Sellersand users need to pay attention to it. This is for any areas other than home.

38 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 49: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Russia Electromagnetic Interference (EMI) Class A statement

People's Republic of China Class A electronic emission statement

Taiwan Class A compliance statement

Appendix B. Notices 39

Page 50: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

40 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 51: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

Index

Aaccessible documentation 35assistance, getting 29

BBIOS code updates 25, 26blade server

configuration requirements 6interconnections among components 7network requirements 7support for external devices 7verifying system compatibility 7

BladeCenter componentscompleting the system installation requirements 6configuration requirements 6interconnections among components 7support for external devices 7verifying system compatibility 7

BladeCenter unitinterconnections among components 7support for external devices 7

boot code updates 15, 26

CCD, documentation 1Class A electronic emission notice 36communication requirements 7completing the system installation requirements 6components 25

completing the system installation requirements 6configuration requirements 6, 26enabling 26replaceable 23software requirements 25, 26troubleshooting 25verifying system compatibility 25

compute node and ServeRAID controllerlink rates

local drives 7configuration

problems 26requirements for BladeCenter components 6

configuring the ServeRAID controller 17contamination, particulate and gaseous 35CRU list 23

Ddevice drivers

documentation 16installing 16, 25, 26updating 15, 25, 26

device drivers, installing 15device problems, Serial Attached SCSI (SAS) 26device-driver documentation 1

documentationdevice driver 1, 16IBM 1installation and configuration requirements for

BladeCenter components 6operating systems 16related 1ServeRAID controller 1, 16troubleshooting information 25

documentation CD 1, 3documentation format 35

Eelectrical specifications 6electronic emission Class A notice 36enabling devices and parameters 26, 27external devices

interconnections among components 7external devices, enabling 26, 27external devices, support requirements 6external hard disk drives, support requirements 6, 25external ports, support requirements 12, 25

FFCC Class A notice 36features

ServeRAID controller 5firmware updates 15, 25, 26functional specifications 6

Ggaseous contamination 35getting help 29guidelines

configuration 26interconnections among components 7support for external devices 7troubleshooting 25verifying system compatibility 25

Hhandling the ServeRAID controller 9hardware and software requirements 3hardware information

web siteIBM products 1

hardware problems 25hardware requirements

completing the system installation 6configuration 6, 26external devices 7interconnections among components 7preinstallation 25

© Copyright IBM Corp. 2012 41

Page 52: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

hardware requirements (continued)replacing components 23support for external devices 6support for external hard disk drives 6, 12, 25support for external ports 25troubleshooting 26verifying system compatibility 25

hardware service and support 30help, getting 29

II/O module

bay locations 26network requirements 7requirements for use with ServeRAID controller 26SAS I/O-module bay combinations in BladeCenter

unit 26upgrading device drivers, firmware, and BIOS code

for 25IBM documentation 1IBM Support Line 30installation

completing the system installation 6preinstallation requirements 6, 25requirements 26

verifying system compatibility 25installing

device drivers for operating systems 16, 25, 26I/O module 25ServeRAID controller 10, 11

installing the ServeRAID controller 9interconnections among components 7internal devices, enabling 26, 27

Llink rates 1Linux operating system, installing device drivers for 16LSI Fusion-MPT 7

Mmanagement module

enabling devices and parameters 26, 27upgrading device drivers, firmware, and BIOS code

for 25Microsoft Windows 2000

installing device driver 15Microsoft Windows operating system, installing device

drivers for 16

Nnetwork requirements 7notes, important 34notices 33

electronic emission 36FCC, Class A 36

Novell Netware operating system, installing devicedrivers for 16

Ooperating systems

documentation 16installing device drivers for 16supported 16

operating-system requirementsfor upgrading device drivers 25, 26

overviewSerial Attached SCSI (SAS) technology 6solving problems 25

Pparameters, enabling 26, 27particulate contamination 35parts listing 23PCI Express 1physical dimensions 6ports 1preinstallation requirements 6, 25problems, solving 25product

information, obtaining from IBM Web site 1public services network, use in 36public telecommunications network, connection to 36publications, related 1

RRAID configurations 1Red Hat Linux

installing device driver 15Red Hat Linux operating system, installing device

drivers for 16related documentation 1removing

ServeRAID controller 13replaceable components 23replacing the ServeRAID controller 23requirements

hardwarecompleting the system installation 6configuration 6, 26external devices 7interconnections among components 7troubleshooting 26verifying system compatibility 25

software 25, 26

SS SAS RAID Controller Module 7SAS

I/O-module bay combinations in BladeCenterunit 26

42 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 53: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

SAS connectivity modulenetwork requirements 7

Serial Attached SCSI (SAS)device problems 26specifications 6technology overview 6

ServeRAIDphysical dimensions 6specifications 6

ServeRAID controllerconfiguring 17documentation 1, 16electrical specifications 6features 5I/O-module requirements 26installing 9, 10, 11parts listing 23removal procedure 13replacing 23solving problems 25upgrading device drivers, firmware, and boot

code 15upgrading device drivers, firmware, and boot code

for 26ServeRAID specifications 6small computer system interface (SCSI) 6software

documentation 1, 16installing 16

software informationweb site

IBM products 1software problems 26software requirements 25, 26software service and support 30solving problems 25specifications

electrical 6parts listing 23physical dimensions 6Serial Attached SCSI (SAS) 6

startup code updates 15supported operating systems

documentation 16web site 16

SUSE Linux operating system, installing device driversfor 16

systemturning on 26

system board, blade server, network requirements 7system compatibility, verifying 25system configuration

problems 26System unit

supported bays for I/O modules 26

Ttechnology overview, Serial Attached SCSI (SAS) 6telephone numbers 30trademarks 33

troubleshootinghardware 25installation problems 25reference documentation 25software problems 25, 26system-configuration problems 26verifying system compatibility 25

UUnited States electronic emission Class A notice 36United States FCC Class A notice 36updating firmware 15updating NVRAM 15, 26upgrading device drivers, firmware 25upgrading device drivers, firmware, and boot code 15upgrading device drivers, firmware, and boot code for

ServeRAID controller 26

Vverifying system compatibility 25

Wweb site

hardware informationIBM products 1

IBM product information 1software information

IBM products 1supported device drivers and utilities 25, 26supported operating systems 16

websitepublication ordering 30support line, telephone numbers 30

Index 43

Page 54: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

44 IBM ServeRAID H1135 for IBM Flex System and BladeCenter Products: Installation and User’s Guide

Page 55: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications
Page 56: IBM ServeRAID H1135 for IBM Flex System and BladeCenter ...public.dhe.ibm.com/systems/support/system_x_pdf/88y7602.pdf · v Disconnect the attached power cords, telecommunications

����

Part Number: 88Y7602

Printed in USA

(1P) P/N: 88Y7602