IBMNETU-MIB DEFINITIONS ::= BEGIN
-------------------------------------------------------------------- IBM Network Utility Enterprise MIB (SNMP Version 1 Format)---------------------------------------------------------------------- This MIB defines the enterprise specific management-- objects for the Network Utility family of products.---- This MIB is defined in the SNMP version 1 SMI format.---- May 06, 1998---- Contact Information:---- Randy Worzella-- IBM Corp.-- G420/664-- Research Triangle Park, NC 27709---- phone: 919-254-2202-- email: worzella@us.ibm.com--------------------------------------------------------------------
IMPORTS enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212;
-- Path to ibmnetu product
ibm OBJECT IDENTIFIER ::= { enterprises 2 }ibmProd OBJECT IDENTIFIER ::= { ibm 6 }ibmnetu OBJECT IDENTIFIER ::= { ibmProd 150 }
-------------------------------------------------------------------- IBM Network Utility Anchor------------------------------------------------------------------ibmnetuadmin OBJECT IDENTIFIER ::= { ibmnetu 1 }ibmnetusystem OBJECT IDENTIFIER ::= { ibmnetu 2 }ibmnetuhardware OBJECT IDENTIFIER ::= { ibmnetu 3 }ibmneturouting OBJECT IDENTIFIER ::= { ibmnetu 4 }ibmnetuswitching OBJECT IDENTIFIER ::= { ibmnetu 5 }
-------------------------------------------------------------------- IBM Network Utility Administrative------------------------------------------------------------------ibmnetuadminproducts OBJECT IDENTIFIER ::= { ibmnetuadmin 1 }
ibmnetumod400 OBJECT IDENTIFIER ::= { ibmnetuadminproducts 1 }
ibmnetuadminOID OBJECT IDENTIFIER ::= { ibmnetuadmin 2 }
ibmnetuadminDebug OBJECT IDENTIFIER ::= { ibmnetuadmin 3 }
-------------------------------------------------------------------- IBM Network Utility System------------------------------------------------------------------
-
8/14/2019 Ibm Ibmnetu
2/6
ibmnetusystemInfo OBJECT IDENTIFIER ::= { ibmnetusystem 1 }ibmnetucfgInfo OBJECT IDENTIFIER ::= { ibmnetusystem 2 }
-------------------------------------------------------------------- IBM Network Utility Hardware------------------------------------------------------------------ibmnetuhardwareGeneral OBJECT IDENTIFIER ::= { ibmnetuhardware 1 }ibmnetuhardware400Specific OBJECT IDENTIFIER ::= { ibmnetuhardware 2 }
-------------------------------------------------------------------- IBM Network Utility Routing------------------------------------------------------------------
-- Nothing defined yet !!
-------------------------------------------------------------------- IBM Network Utility Switching------------------------------------------------------------------
-- Nothing defined yet !!
-------------------------------------------------------------------- Hardware Information------------------------------------------------------------------
-------------------------------------------------------------------- Hardware Chip Set Information------------------------------------------------------------------
ibmnetuEnetChipSet OBJECT IDENTIFIER ::= { ibmnetuadminOID 1 }
-------------------------------------------------------------------- The Network Utility 10 Megabit Ethernet LAN adapters use an Ethernet-- chipset comprised of the following:---- MultiProtocolChip MPC-1 ASIC Toshiba---- 10BaseT PE65428 Pulse Engineering
-- DP83912 National-- SF1012 Valor---- 10Base2 S553-10060AE Belfuse-- DP8392CV-1 National---- For the Ethernet MIB, however, the OID identifying the chipset-- will simply be enetChipSetToshiba.---- The Network Utility 10/100 Megabit Fast Ethernet LAN adapters use an-- Ethernet chipset comprised of the following:---- Controller AM79C971 Advanced Micro Devices
---- Physical Layer DP83840A National Semi---- Content Addressable MU9C4480A Music Semi-- Memory---- TB Filter PLA Xilinx PLA Xilinx---- For the Ethernet MIB, however, the OID identifying the chipset-- will simply be enetChipSetAMD.
-
8/14/2019 Ibm Ibmnetu
3/6
--------------------------------------------------------------------enetChipSetToshiba OBJECT IDENTIFIER ::= { ibmnetuEnetChipSet 1 }enetChipSetAMD OBJECT IDENTIFIER ::= { ibmnetuEnetChipSet 2 }
-------------------------------------------------------------------- Hardware PCI Adapter Information------------------------------------------------------------------
ibmnetuPCIAdapTable OBJECT-TYPE SYNTAX SEQUENCE OF IbmnetuPCIAdapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of information about PCI adapters in this box." ::= { ibmnetuhardwareGeneral 1 }
ibmnetuPCIAdapEntry OBJECT-TYPE SYNTAX IbmnetuPCIAdapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing objects to describe the adapter
in a given slot." INDEX { ibmnetuPCIAdapSlotNum } ::= { ibmnetuPCIAdapTable 1 }
IbmnetuPCIAdapEntry ::= SEQUENCE { ibmnetuPCIAdapSlotNum INTEGER, ibmnetuPCIAdapType INTEGER, ibmnetuPCIAdapOperStatus INTEGER }
ibmnetuPCIAdapSlotNum OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The number identifying a slot location where an adapter can be inserted." ::= { ibmnetuPCIAdapEntry 1 }
ibmnetuPCIAdapType OBJECT-TYPE SYNTAX INTEGER { unknown (1),
not-present (2), atm-mmf-lic294 (3), reserved1 (4), atm-smf-lic295 (5), reserved2 (6), token-ring-lic280 (7), escon-lic287 (8), reserved3 (9), reserved4 (10), serial-rs232-lic282 (11),
-
8/14/2019 Ibm Ibmnetu
4/6
serial-v35-lic290 (12), serial-x21-lic291 (13), ethernet-lic281 (14), ethernet-fast-lic288 (15), serial-hssi-lic289 (16), fddi-lic286 (17), reserved5 (18), reserved6 (19), parallel-channel-lic299 (20)} ACCESS read-only STATUS mandatory DESCRIPTION "The type of adapter that is inserted into this slot. If no adapter is present, the variable will take the value not-present(2). The enumerations marked reserved# are saved for future enhancements." ::= { ibmnetuPCIAdapEntry 2 }
ibmnetuPCIAdapOperStatus OBJECT-TYPE SYNTAX INTEGER { unknown (1), not-configured (2), not-present (3), does-not-apply (4),
enable-pending (5), enabled (6), disable-pending (7), disabled (8), not-initialized (9), unknown-device (10), hardware-error (11), not-powered (12), diagnostics (13), wrs-available (14), mis-configured (15)} ACCESS read-only STATUS mandatory
DESCRIPTION "The operational status of this PCI adapter.
unknown (1) : If there was problem determining the operational status of the adapter.
not-configured (2) : If the adapter inserted in the slot is recognized but no router configuration exists.
not-present (3) : If no adapter is currently inserted.
does-not-apply (4) : If this adapter does not contain an operational state.
enable-pending (5) : If commands have been issued to enable the adapter but have not been completed.
enabled (6) : If commands have been successfully issued to enable the adapter.
disable-pending (7) : If commands have been issued to disable the adapter but have not been completed.
-
8/14/2019 Ibm Ibmnetu
5/6
disabled (8) : If commands have been successfully issued to disable the adapter.
not-initialized (9) : If the adapter has not completed its initialization.
unknown-device (10) : If the adapter inserted in the slot can not be recognized.
hardware-error (11) : If the adapter can not be used nor made ready to be used.
not-powered (12) : If the adapter has had a problem obtaining power from its slot.
diagnostics (13) : If the adapter is currently undergoing diagnostics.
wrs-available (14) : If the adapter is currently configured and available for WAN restoral.
mis-configured (15) : If the adapter is inserted in the slot but the router configuration is of a different type."
::= { ibmnetuPCIAdapEntry 3 }
-------------------------------------------------------------------- Management application graphic accelerator table------------------------------------------------------------------
ibmnetuGraphicTable OBJECT-TYPE SYNTAX SEQUENCE OF IbmnetuGraphicEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of information mapping a slot and port to
an interface table ifIndex. An entry exists in this table only if the ifConnectorPresent object is true" ::= { ibmnetuhardwareGeneral 2 }
ibmnetuGraphicEntry OBJECT-TYPE SYNTAX IbmnetuGraphicEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry mapping slot and port to an interface table ifIndex." INDEX { ibmnetuGraphicSlotNum, ibmnetuGraphicPortNum }
::= { ibmnetuGraphicTable 1 }
IbmnetuGraphicEntry ::= SEQUENCE { ibmnetuGraphicSlotNum INTEGER, ibmnetuGraphicPortNum INTEGER, ibmnetuGraphicifIndex INTEGER
-
8/14/2019 Ibm Ibmnetu
6/6
}
ibmnetuGraphicSlotNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number identifying a slot location where an adapter can be inserted." ::= { ibmnetuGraphicEntry 1 }
ibmnetuGraphicPortNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number identifying a port on a given adapter. A port implies a physical connector is associated with it." ::= { ibmnetuGraphicEntry 2 }
ibmnetuGraphicifIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory
DESCRIPTION "The ifIndex of the interface table entry associated with this port on an adapter. By definition, the ifEntry has ifConnectorPresent = true." ::= { ibmnetuGraphicEntry 3 }
END