IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap...

49
IBM Certified Solution Designer - Datacap Taskmaster Capture 8.1 Number : C2070-588 Passing Score : 624 Time Limit : 120 min File Version : 8.7.124 http://www.gratisexam.com/ NOTE: The following exam practice questions and answers have been created using material available from IBM, and are designed to help exam takers prepare for this test. Any similarities between the material in this file and the actual exam are due only to the common information used to create them. To learn more about Datacap and how to design solution, IBM Redbook offers the following book FREE of charge as a PDF or EPUB. It is the perfect study companion to this testing engine: Implementing Imaging Solutions with IBM Production Imaging Edition and IBM Datacap Taskmaster Capture http://publib-b.boulder.ibm.com/abstracts/sg247969.html Sections 1. Topic 1 2. Topic 2

Transcript of IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap...

Page 1: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

IBM Certified Solution Designer - Datacap Taskmaster Capture 8.1

Number: C2070-588Passing Score: 624Time Limit: 120 minFile Version: 8.7.124

http://www.gratisexam.com/

NOTE: The following exam practice questions and answers have been created using material availablefrom IBM, and are designed to help exam takers prepare for this test. Any similarities between the material in this file and the actual exam are due only to thecommon information used to create them.

To learn more about Datacap and how to design solution, IBM Redbook offers the following book FREE ofcharge as a PDF or EPUB. It is the perfectstudy companion to this testing engine:

Implementing Imaging Solutions with IBM Production Imaging Edition and IBM Datacap TaskmasterCapture

http://publib-b.boulder.ibm.com/abstracts/sg247969.html

Sections1. Topic 12. Topic 2

Page 2: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

Exam A

QUESTION 1A developer has placed the following code on a field named DateValue which is a child of a page:

Which of the following input>>>output values would NOT be expected?

A. Default>>>2000/01/01B. 2013/02/34>>>2014/01/01C. NULL Value>>>2014/01/01D. October 20, 2013>>>2013/10/20

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:

QUESTION 2A customer has images that have machine print as well as handwritten data on the image. Is it necessary tohave an OCR_s or OCR_a engine as well as an ICR engine to extract/read data from the image, and why?

A. Yes, both OCR_s and ICR_c engines will have to be used.B. No, ICR_c engine works well with hand-printed and machine-printed text.C. No, OCR_s engine works well with hand-printed and machine-printed text.D. No, OCR_a is the only engine that can read hand-printed and machine-printed text.

Correct Answer: BSection: Topic 1Explanation

Explanation/Reference:

QUESTION 3A customer has remote users that will be scanning in paper documents for their IBM Datacap Taskmasterapplications outside of their office network. What is the BEST method of ingestion for the customer'sapplication?

A. Use the Taskmaster Web client to scan and then upload the documents, using a TWAIN driver .B. Use Taskmaster DotScan using ISIS or TWAIN scanner for the remote user to scan in new batches.C. Use a fax machine where remote user fax images to a Rightfax server which is ingested by a

RuleRunner server using a OpenTextFaxServertask.

D. Use a third party application with a scanner for the remote user who then upload the images to anetwork folder which is ingested by aRuleRunner server using VScan task.

Page 3: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:

QUESTION 4An IBM Datacap Taskmaster Capture system is being architected to support a large capture processingoperation consisting of 500 dedicated Taskmaster web users located in the same facility. What is theminimum recommended number of Microsoft IIS instances?

A. TwoB. ThreeC. FourD. Five

Correct Answer: DSection: Topic 1Explanation

Explanation/Reference:Since Taskmaster Web is recommended no more than 100 users....

QUESTION 5The solution designer is creating a standalone FastDoc application and needs to add a workflow. Whatconstruct is created to contain the workflow?

http://www.gratisexam.com/

A. Task ProfileB. Batch ProfileC. Batch monitorD. FastApp template

Correct Answer: BSection: Topic 1Explanation

Explanation/Reference:

QUESTION 6A race condition can occur when two or more threads are able to access shared data. Which statement isTRUE about the automated vscan task?

A. By default all batch creation tasks are synchronized in memory and can run simultaneously withoutconflict.

B. Batch creation tasks from two different applications looking in the same input folder can runsimultaneously without conflict.

C. Batch creation tasks from two different applications looking in two different input folders can runsimultaneously without conflict.

D. Batch creation tasks from a single application but in separate jobs looking in the same input folders canrun simultaneously without conflict.

Page 4: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

Correct Answer: CSection: Topic 1Explanation

Explanation/Reference:

QUESTION 7A solution designer is using the Application Wizard to create a new project. What are some of the objecttypes, within the hierarchy, that are created by default?

A. Document, Page and FieldB. Batch, Document Separators, PageC. Variables, Document, Page and FieldD. Main Page, Trailing Page and Other Page

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:

QUESTION 8An IBM Datacap Taskmaster developer uses IBM Datacap Taskmaster Rulerunner Manager to create athread and sets the thread to run in sequential mode (Mixed Queueing checkbox disabled). They want toconfigure the thread to process tasks as follows:

How would the developer configure priority values on the thread nodes to achieve the above sequence?

A. APT priority=1, TravelDocs priority=2, APT:VScan priority=2, TravelDocs:VScan priority=1,TravelDocs:Profiler priority=2

B. APT priority=2, TravelDocs priority=1, APT:VScan priority=1, TravelDocs:VScan priority=2,TravelDocs:Profiler priority=1

C. APT priority=0.5, TravelDocs priority=1, APT:VScan priority=1, TravelDocs:VScan priority=0.5,TravelDocs:Profiler priority=1

D. APT priority=1, TravelDocs priority=0.5, APT:VScan priority=1, TravelDocs:VScan priority=1,TravelDocs:Profiler priority=0.5

Correct Answer: BSection: Topic 1Explanation

Explanation/Reference:

QUESTION 9When IBM Datacap Taskmaster Capture converts a single multi-page file to individual a TIFF file, whatdetermines the maximum number of files that are created and output using the Convert library actions?

Page 5: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

A. The SetMaxImageFiles action determines the maximum.B. There is no restriction on the maximum number of output files.C. Inherently a maximum of 1,296 individual TIFF files can be output.D. Individual Convert actions properties determine the maximum number of output files.

Correct Answer: CSection: Topic 1Explanation

Explanation/Reference:

QUESTION 10A company is experiencing some batch aborts that have been traced to recognition failure in the OCRengine. What is the recommendation to alleviate this?

A. Use managed recognition.B. Switch to another engine that will sacrifice accuracy for stability.C. Check to make sure that the input images are oriented correctly.D. Check the image file sizes. OCR will not work on images bigger than 82.3K. A lower resolution will be

required.

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:

QUESTION 11A customer scans in a document and the template is not recognized within the IBM Datacap TaskmasterCapture application. What happens when the image or page is not identified?

A. The unidentified page is classified as "Default."B. The unidentified page is removed from the DCO.C. The page is classified as the previous identified page.D. The page is classified as "Other" and has to be otherwise identified.

Correct Answer: DSection: Topic 1Explanation

Explanation/Reference:

QUESTION 12The client requirements outline the need to return documents to the original scan operator (or department)for verification. What task detail settings will provide this functionality?

A. Mode: Router and Store: User IDB. Queue by: User and Store: NoneC. Mode: Router and Queue by: UserD. Queue by: User and Store: User ID

Correct Answer: DSection: Topic 1Explanation

Page 6: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

Explanation/Reference:

QUESTION 13A company identifies pages by the presence of key words on a page. While identifying a page containingALL of the key words (Car, Flight, Room) immediately after ingestion, the RecognizePageOCR_S() actionfails.

What would be the page type?

A. OtherB. Air_TicketC. Room_ReceiptD. Rental_Agreement

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:

QUESTION 14A customer has more than 200 types of documents to be scanned using IBM Datacap TaskmasterCapture. Some documents have more than 100 index fields that need to be captured. How manydocuments / pages / fields can be created in the DCO?

A. Unlimited documents / pages / fieldsB. Limited to 50 documents / pages / fieldsC. Limited to 10 documents / pages / fieldsD. Limited to 100 documents / pages / fields

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:

QUESTION 15Which of the following is NOT an "out of the box" export target for IBM Datacap Taskmaster Capture?

A. Microsoft SharePointB. Microsoft SQL Database

Page 7: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

C. Open Text Cloud StorageD. IBM Content Manager (CM8)

Correct Answer: CSection: Topic 1Explanation

Explanation/Reference:

QUESTION 16An IBM Datacap Taskmaster developer has a specific page type which needs custom verify panels to becreated for both thick client and web interfaces. Which Datacap components can the developer leverage todisplay custom verify interfaces to the end user?

A. FastDoc for thick client and AVerify.aspx for web.B. DotEdit for thick client and VeriFine.aspx for web.C. DotScan for thick client and ImgEnter.aspx for web.D. Batch Pilot for thick client and AIndex.aspx for web.

Correct Answer: BSection: Topic 1Explanation

Explanation/Reference:

QUESTION 17The IBM Datacap Taskmaster Capture Studio Test tab provides all EXCEPT the following runtimeprocessing information?

A. Log file contentsB. Recognition zonesC. Custom action codeD. Batch hierarchy variables

Correct Answer: CSection: Topic 1Explanation

Explanation/Reference:

QUESTION 18For optimal testing results of fingerprints created with AnalyzeImage, which of the following imageprocessing settings is NOT required?

A. DeskewB. Line removalC. Dot RemovalD. Border removal

Correct Answer: BSection: Topic 1Explanation

Explanation/Reference:

QUESTION 19

Page 8: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

A solution designer has a lot of users who will be using the IBM Datacap Taskmaster Web Client accessingthe new tmweb.net site. Assume the following has been done: OpenC:\Datacap\support\WebConfiguration folder and make backup copy of WebClientConfig.exe.config fileOpen WebClientConfig.exe.config file and change server name in: <value>http://localhost/tmweb.net</value> Save and close .config file What else needs to be done to implement and configure all of the users'Internet Explorer web browsers?

A. Send WebClientConfig.exe.config, Datacap.Config.dll, and WebClientConfig.exe.B. Send WebClientConfig.exe.config, Datacap.Config.dll, and WebClientConfig.exe to user with

instructions to run IE test page.C. Send WebClientConfig.exe.config, Datacap.Config.dll, and WebClientConfig.exe to user with

instructions to add tmweb.net address as Trusted Site, configure and test Internet Explorer usingpackage.

D. Send WebClientConfig.exe.config, Datacap.Config.dll, and WebClientConfig.exe to user withinstructions to add tmweb.net address asRestricted sites, configure and test Internet Explorer using package.

Correct Answer: CSection: Topic 1Explanation

Explanation/Reference:

QUESTION 20An IBM Datacap Taskmaster Capture developer has created a custom action CustomLib.Echo, inTaskmaster V8.1, that calls the standard WriteLog method to output the data to a file. The action is calledwithin the following context:

What file will contain the output from the custom component?

A. customfn.logB. customrs_rrs.logC. customtask_rrs.logD. customlib_echo_rrs.log

Correct Answer: CSection: Topic 1Explanation

Explanation/Reference:

QUESTION 21In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server isActive/Passive using a Microsoft Cluster. In Taskmaster V8.1 multiple Taskmaster servers can beconfigured Active/Active for an application for load balancing and/or failover. A solution designer wants totake advantage of using Rulerunner, to have the ability to roam back and forth periodically amongTaskmaster servers. Which file needs to be edited to allow this capability?

A. .APP file

Page 9: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

B. PATHS.iniC. settings.iniD. Imagefix.ini

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:

QUESTION 22A pharmaceutical company has faxed documents and some of the documents have the content skewed.What method is used to de-skew the content on the faxed documents using the IBM Datacap Taskmastersystem?

A. Use the action Rotate Image.B. Cannot de-skew because of fax line present at beginning of image.C. Using image enhancement actions, de-skew the contents of the image.D. Redact the fax line and then use image enhancement action, de-skew the contents of the image.

Correct Answer: DSection: Topic 1Explanation

Explanation/Reference:

QUESTION 23A system administrator has setup an IBM Datacap Taskmaster architecture which includes using ActiveDirectory (ADSI) domain accounts to logon to Datacap. The Taskmaster server has already beenconfigured for ADSI and the domain groups have been configured within each application. What credentialsshould be entered by the end user to access the IBM Datacap tmweb application?

A. Logon to the workstation as a domain user account, when prompted for credentials enter only domainuser's short name, leaving the password field blank.

B. Logon to the workstation as a domain user account, when prompted for credentials enter a validDatacap Taskmaster Authentication username and password.

C. Logon to the workstation as a local user account, when prompted for credentials enter the full username ([email protected]) and thedomain account's associated password.

D. Logon to the workstation as a domain user account, when prompted for credentials enter the full username ([email protected]) and the domain account's associated password.

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:

QUESTION 24Analysis of a customer requirements shows that 10 million new documents need to be scanned andingested each day from various sources at various worldwide locations. These documents must be in thecorporate archive by the beginning of the next business day. Which option should the solution designerrecommend as being the MOST reliable and cost effective document ingestion solution?

A. Overnight shipping of all documents to the central site which has many high-speed scanners.B. Distributed capture to be performed at various regional centers with centralized indexing and control.C. Courier contracts from outlying locations to regional centers with high-speed scanners connected to the

Page 10: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

corporate archive.D. Distributed capture with localized indexing and control, this has multiple scan sites feeding regional

centers with high-speed dedicated connections to the corporate archive .

Correct Answer: DSection: Topic 1Explanation

Explanation/Reference:

QUESTION 25A solution designer is helping a customer list out the various actions that could be required to implementexport of data from IBM Datacap Taskmaster to the IBM FileNet P8 repository. Which of the followingFileNet P8 actions does NOT exist?

A. FNP8_SetDocTitleB. FNP8_SetPropertyC. FNP8_CreateFolderD. FNP8_SetMimeType

Correct Answer: DSection: Topic 1Explanation

Explanation/Reference:

QUESTION 26A company needs to have an application that checks to see if the line_total field on an unknown number ofline items matches the total field found on the first page. Assuming that all of the data from the line items isstored on the first page, what is the recommended action?

A. A custom action is required.B. CheckSubFields("total","LineTotal")C. CheckSubFields("line_total","total")D. CalculateFields("'line_total' = 'total'")

Correct Answer: DSection: Topic 1Explanation

Explanation/Reference:

QUESTION 27A telecommunication company has various documents to scan and extract data. Half of these documentsare internal documents that have templates that were created within the company; the other half of thedocuments are documents coming from other vendors and are not consistent in terms of template. In theapplication design, how would these documents be logically differentiated?

A. Large and small documents.B. Color and black & white documents.C. Structured and unstructured documents.D. Fingerprintable and non-fingerprintable documents.

Correct Answer: CSection: Topic 1Explanation

Page 11: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

Explanation/Reference:

QUESTION 28A field contains the value "Pizzaz". It runs through the validation action AllowOnlyChars(A- Z,a-z). Whatwould be the expected value of the field after it runs through this action?

A. zzazB. PizzazC. PIZZAZD. The value would be blank.

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:

QUESTION 29An automobile leasing company wants to keep all the records related to the purchase, finance, lease, andtitle of a vehicle in a single electronic file. 90% of these documents are received via OpenTextRightFaxServer V9. The customer has requested the Solution Designer to identify actions that could beused to import faxes from the fax server. Which of the following actions should the Solution Designerselect?

A. SetServerName, SetUser.B. Connect, SetServerName.C. SetProtocol, SetFaxNumber.D. SetAbortTimeout, SetPassword.

Correct Answer: BSection: Topic 1Explanation

Explanation/Reference:

QUESTION 30Which is the best way to use the RV2 application if the same reports are consistently viewed?

http://www.gratisexam.com/

A. Add the reports to the dashboard.B. RV2 remembers and opens the last reports viewed.C. Select the reports in the report list and click 'Run Report'D. Create a filter so the reports are the only ones available in the selection list.

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:

Page 12: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

QUESTION 31A solution designer would like to meet a financial services customer's business requirement for exportingimages and associated metadata to a Microsoft Sharepoint 2010 Repository by using the built-inSharePoint connector actions. Which of the following is the correct sequence of action steps, that need tobe configured to enable a successful export to the target repository?

A. Log into the SharePoint library,Identify and set up the URL of the SharePoint library, Specify the content type,Set the format in which to release documents to the SharePoint library, such as TIF or PDF,Create a folder in the SharePoint into which to upload documents, Set the column properties (indexvalues) in SharePoint for the documents to upload, Upload the indexed documents into the SharePointlibrary.

B. Identify and setup the URLof the SharePoint library, Log into the SharePoint library,Set the format in which to release documents to the SharePoint library, such as TIF or PDF,Specify the content type,Create a folder in the SharePoint into which to upload documents, Upload document,Set the column properties (index values) in SharePoint for the documents to upload, Upload thedocument indexes.

C. Specify the content type,Log into the SharePoint library,Identify and set up the URL of the SharePoint library, Set the format in which to release documents tothe SharePoint library, such as TIF or PDF,Create a folder in the SharePoint into which to upload documents, Set the column properties (indexvalues) in SharePoint for the documents to upload, Upload the indexed documents into the SharePointlibrary.

D. Log into the SharePoint library,Create a folder in the SharePoint into which to upload documents, Specify the content type ,Set the format in which to release documents to the SharePoint library, such as TIF or PDF,Create a folder in the SharePoint into which to upload documents, Upload the indexed documents intothe SharePoint library, Set the column properties (index values) in SharePoint for the documents youwant to upload.

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:

QUESTION 32A consultant is in a meeting with a group of IT managers for a large bank. The consultant is asked todiagram a high level communication architecture diagram of a IBM Datacap Taskmaster Capture serverand it's clients. What type of communication is used between a IBM Datacap Taskmaster Capture serverand it's clients?

A. OLE DB.B. Common Internet File System (CIFS).C. IBM Datacap Taskmaster Capture client protocol.D. IBM Datacap Taskmaster Capture socket protocol.

Correct Answer: DSection: Topic 1Explanation

Explanation/Reference:

QUESTION 33A large corporate customer is designing an IBM Datacap Taskmaster Capture application for a productionenvironment that requires a high volume of images, and will be using fingerprinting to identify every page.They are currently in the architecture design phase of the production system. The customer is licensed for

Page 13: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

Microsoft SQL 2008 Server and Microsoft Office Access. What database and server configuration shouldthe customer use for their production environment?

A. Use Microsoft Access for the Admin/Engine/Fingerprint DB on the same server as the TaskmasterServer.

B. Use Microsoft SQL DB for the Admin/Engine/Fingerprint where a separate SQL DB server is used andthe DBs are stored on a separate file server.

C. Use Microsoft Access for the Fingerprint DB on the same server as the Taskmaster Server, and useMicrosoft SQL DB for the Admin/Engine DB on a separate SQL DB server.

D. Use Microsoft SQL DB for the Fingerprint DB, on a separate SQL DB server, and use Microsoft Accessfor the Admin/Engine DB on the same server as the Taskmaster Server.

Correct Answer: BSection: Topic 1Explanation

Explanation/Reference:

QUESTION 34A customer is currently undertaking a large IBM Datacap Taskmaster Capture implementation. Theyrequire maximum processing power of their Taskmaster server hardware to handle the large volume. Whatwould be the BEST Taskmaster server configuration to handle their volume?

A. Failover configurationB. Distributed configurationC. Centralized configurationD. Load sharing configuration

Correct Answer: DSection: Topic 1Explanation

Explanation/Reference:

QUESTION 35A solution designer uses the IBM Datacap Taskmaster Application Manager to reference theImportLocation value and the connection string to the xyz_app Engine database.

Page 14: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

Using the screenshots above, what reference syntax would be used as action parameters to read theImportLocation and Engine values?

A. @APPVAR(values/gen/?[1]:v)@APPVAR(tmengine:cs)

B. @APPPATH(values/gen/?[1]:v)@APPVAR(engine:cs)

C. @APPVAR(dco_*[1]/importlocation:cv)@APPVAR(tmengine:cs)

D. @APPPATH(dco_*[ValueName]/ImportLocation:cv)@APPVAR(engine:db)

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:

QUESTION 36A solution designer is setting up NENU to execute tasks such as logging, reporting and batch processing.Different rules need to be executed at different times and with different triggers. Which is NOT a validexecution method?

A. Manually using the NENU Manager.B. Manually using the Application Manager.C. Automatically using the Windows Task Scheduler.D. Automatically as a task of the workflow of an application.

Correct Answer: B

Page 15: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

Section: Topic 1Explanation

Explanation/Reference:

QUESTION 37A company is building a High Availability environment to ensure maximum up time in their data center.From the information given, where should the batches and application folder reside?

A. On the NAS\SAN.B. On the Rulerunner server.C. On the Taskmaster web server.D. On the Taskmaster server nested within the Datacap application files.

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:

QUESTION 38A system administrator needs to setup a distributed IBM Datacap Taskmaster Web server. As the IBMDatacap Taskmaster Server service is located remotely, the administrator needs to synchronize theencryption key to the web server. How should the administrator synchronize the encryption keys?

A. Export the key file on the IBM Datacap Taskmaster Capture server and copy the key transfer file to theTaskmaster folder on the IBM Datacap Web server.

B. Use the IBM Datacap SitManager utility to create the encrypted admin password and save it to a file inthe Taskmaster folder on the IBM Datacap Web server.

C. Copy the IBM Datacap Taskmaster Capture application(s) to a shared location and update the localdatacap.xml file to point to the shared application directories.

D. Point the IBM Datacap Taskmaster Web server's datacap.xml file to the IBM Datacap Taskmasterserver and the encryption key will besynchronized automatically.

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:

QUESTION 39The client has outlined in the discovery phase of the project that they want to incorporate two geographicallocations, A and B respectively. Each location will be processing their own document types but will onlyneed to export the images to an IBM FileNet P8 server that exists in location A. The clients wide areanetwork is slow. Where should the batch and project files be stored?

A. Taskmaster server at location A.B. Taskmaster Web server at location A.C. Local network share at locations A and B.D. Taskmaster Rulerunner server share at locations A and B.

Correct Answer: CSection: Topic 1Explanation

Explanation/Reference:

Page 16: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

QUESTION 40What is Intellocate used for?

A. Context sensitive help.B. Learning zones for fingerprints.C. Autocorrection at data entry time.D. Finding data by regular expression or keyword.

Correct Answer: BSection: Topic 1Explanation

Explanation/Reference:

QUESTION 41Which of the following is the minimum hardware recommended to operate a IBM Datacap TaskmasterServer and file server?

A. Intel Core 2 Duo E6850 (3.0 GHz) AMD Athlon or Sempron, Ram 4 GB, 50 GB DiskB. Intel Core 2 Duo E6850 (3.0 GHz) AMD Athlon or Sempron, Ram 2 GB, 50 GB DiskC. Pentium Dual Core E2160 (1.80 GHz) AMD Opteron, Athlon, or Sempron, Ram 1 GB, 10 GBD. Intel Core 2 Duo T7500 (2.20 GHz) AMD Opteron, Athlon or Sempron Ram, 3 GB, 100 GB Disk

Correct Answer: DSection: Topic 1Explanation

Explanation/Reference:

QUESTION 42A consultant, while developing an IBM Datacap Taskmaster car rental capture application, must incorporatea lookup database to validate whether a field contains a value for a rental car type that is in a list ofpermitted values. The list of permitted rental car types are:

A. Compact b)Standard c)Full Size d)SUV e)Other In order to perform these database lookups, whichactions should be used together to be incorporated into a DCO Ruleset?

A. OpenConnection > ExecuteSQL > CloseConnectionB. BeginConnection > ExecuteSQL > CloseConnectionC. OpenConnection > PopulateWithResult > ExecuteSQL > CloseConnectionD. ClearLookupResults > OpenConnection > ExecuteSQL > CloseConnection

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:

QUESTION 43

Page 17: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

A customer has an IBM Datacap Taskmaster application and would like to use a RuleRunner server toautomatically ingest images from a network folder. The customer would like that the network folder to bescanned every 10 minutes.

What field and configuration needs to be set for the RuleRunner server to work best for the customer'sneeds?

A. Set the Sleep For to 600 with Mix Queuing enabled.B. Set the Sleep For to 600 with Mix Queuing disabled.C. Set the Thread Timeout to 600 with Mix Queuing enabled.D. Set the Thread Timeout to 600 with Mix Queuing disabled.

Correct Answer: BSection: Topic 1Explanation

Explanation/Reference:

QUESTION 44A developer is migrating an IBM Datacap Taskmaster Capture application from version 8.0.1 to 8.1 and has

Page 18: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

custom Batch Pilot forms that need to be converted to DotEdit panels. The developer has exported thelayout.xml file using Batch Pilot. Which of the following would be included in the layout.xml file?

A. Control types: dcedit, dcimage, and labelAttributes: all

B. Control types: dcedit, dcimage, and comboboxAttributes: control name and position

C. Control types: allAttributes: control type, control name, and position

D. Control types: dcedit, dcimage, combobox and label Attributes: control type, control name, position, andother attributes.

Correct Answer: DSection: Topic 1Explanation

Explanation/Reference:

QUESTION 45As a solution designer implementing ADSI and LDAP, web.config must be edited for authentication to workproperly. What must be set within RV2 web.config?

A. Locate and edit web.config, adding key="EnableADSI" value="True"/ and save.B. Locate and edit web.config, adding key="EnableLDAP" value="true"/ and save.C. Locate and edit web.config, adding key="EnableLDAP" value="false"/ and save.D. Locate and edit web.config, adding key="EnableADSI" value="False"/ and save.

Correct Answer: BSection: Topic 1Explanation

Explanation/Reference:

QUESTION 46

Page 19: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

A developer is trying to add a new task profile, using the add button in the Task profiles tab, but does notunderstand why they cannot use the add button to add a new task profile in Datacap Studio.

What does the developer have to do to succeed in adding a new task profile?

A. Lock the task profiles.B. Lock the ruleset, and lock the task profiles.C. Lock the document hierarchy, and lock the ruleset.D. Lock the document hierarchy, lock the ruleset, and lock the task profiles.

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:

QUESTION 47A solution designer is creating a function to do image acquisition. One of the requirements is to use theimage directory specified in the application configuration file. What is the BEST way to specify the locationof the image directory in the function?

Page 20: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

http://www.gratisexam.com/

A. Use an action that employs the @APPPATH smart parameter to retrieve the directory.B. Use an action that contains the actual directory structure, e.g.

C:\Datacap\TravelDocs\Image.C. Place the function in a rule that associated with a DCO field that contains the location of the directory.D. Create a custom variable using the Application Manager, then use an action that employs the

@APPPATH smart parameter to specify the directory.

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:

QUESTION 48An IBM Datacap Taskmaster administrator gets a report that station id "verify12" cannot login. Theadministrator reviews the logs and determines that the maximum number of virtual stations for that stationid has been reached and the count must be reset. In tmweb, where can the administrator reset the virtualstation count?

A. Administrator tab > Users sub-tab > select the "verify12" user id > click the "Clear Sessions" button.B. Administrator tab > Stations sub-tab > select the "verify12" station id > click the "Clear Virtuals" button.C. Monitor tab > Station Monitor sub-tab > select the "verify12" station id > click the "Clear Virtuals" button.D. Monitor tab > Station Monitor sub-tab > select the "verify12" station id link > in the "Station Details"

dialog, click the "Clear Sessions" button.

Correct Answer: BSection: Topic 1Explanation

Explanation/Reference:

QUESTION 49A solution designer is building an IBM Datacap Taskmaster Capture application and has determined thatthe order of the rule execution is incorrect. Where can the designer look to determine the order of ruleexecution?

A. The result of the previous action.B. The order of the rule in the Ruleset.C. The order of the Ruleset (containing the rule) in the Task Profiles.D. The order of the Ruleset (containing the rule) in the Rulesets panel in DStudio.

Correct Answer: CSection: Topic 1Explanation

Explanation/Reference:

QUESTION 50

Page 21: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

A solution designer has created a static panel layout using the Custom Layout Generator. The file is named"custompanellayout.ascx". The new static panel layout will be used with a page type of Rental_Agreement.Where would the new static panel be stored?

A. bin folderB. Task folderC. App_Data folderD. App_Themes folder

Correct Answer: BSection: Topic 1Explanation

Explanation/Reference:

QUESTION 51An IBM Datacap Taskmaster Capture solution designer is using locate rules to dynamically locate field dataon a page. What action is used to store the value in the field?

A. UpdateFieldB. ValueInFieldC. AppendToFieldD. UpdateDCOField

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:

QUESTION 52A solution designer is building a function to that creates a data file for the current page.What action is used to create the data file?

A. CreateFieldsB. CreateDocumentsC. CreatePageDataFileD. CreateRuntimeDataFile

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:

QUESTION 53A solution designer wants to use FastDoc for export to a Microsoft SharePoint server. When running theexport task within FastDoc the following error was displayed:

Which utility can be use to test the SharePoint connection?

A. SpTest.exe

Page 22: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

B. TestSP.exeC. NENUConfig.exeD. TryFPservices.exe

Correct Answer: BSection: Topic 1Explanation

Explanation/Reference:

QUESTION 54Users are trying to log into their IBM Datacap Taskmaster application using their own user ID and a stationID of 5. They cannot login and receive the following error message: "Login failed. Taskmaster has reachedthe maximum allowed number [#] of stations". What does the Taskmaster administrator need to do?

A. Go into the Administrators tab then Stations tab. Use the "Clear virtuals" button in station ID 5.B. Go into the Administrators tab then Users tab. Reset password for all the users unable to login.C. Go into the Administrators tab then Stations tab. Check that the permissions are set correctly for station

ID 5.D. Go into the Administrators tab then Stations tab. Delete Station ID 5, add new station ID, make users

use a new station ID.

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:

QUESTION 55A developer uses IBM Datacap Studio's Application Wizard to make a copy of an existing Datacapapplication. Which of the following items are NOT copied from the target application by the ApplicationWizard?

A. Application-specific action libraries.B. Setup DCO node to rules mappings.C. Batches and associated engine database entries.D. Fingerprint images and associated database entries.

Correct Answer: CSection: Topic 1Explanation

Explanation/Reference:

QUESTION 56An insurance company uses IBM Datacap Taskmaster Capture RV2 reports to monitor batch processingmetrics. Management has requested a new report be created containing data that is not captured in thedefault RV2 reports databases. Select the two appropriate answers that identify valid steps in the process tobuild a new custom report?

A. Copy RDLC file to reports folder.B. Copy RDLC file to application folder.C. Add report reference to applications .app file.D. Configure Visual Studio ReportViewer Control.E. Set Visual Studio project Platform Target property to Any CPU.

Correct Answer: AD

Page 23: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

Section: Topic 1Explanation

Explanation/Reference:

QUESTION 57A solution designer notices that, over time, input files for prescanned images, as well as folders and filesassociated with completed and unfinished batches, accumulate and consume a lot of disk space. Whichtwo FastDoc functions allow you to delete input files along with the finished and unfinished batches to freeup disk space?

A. Delete selected batch.B. Archive selected batch.C. Purge finished batches.D. Delete finished batches.E. Select batch and delete from Window Explorer.

Correct Answer: ACSection: Topic 1Explanation

Explanation/Reference:

QUESTION 58A solution designer has to develop a 1040EZ tax processing capture application. It is required that theapplication have rules to detect and perform validations on each of the following requirements: 1)SocialSecurity Field's Length should be tested to make sure its length is exactly nine characters. 2)Validate theAdjustedGrossIncome field as total sum of other fields mainly: Total Wages, Taxable Income,Unemployment compensation. Which of the following validation functions should be performed at the DCOfield level to meet these requirements in that order ?

A. IsFieldLengthMin, CalculateB. IsFieldLengthMax, CalculateC. IsFieldLengthMin, IsFieldLengthMaxD. IsFieldLengthMin, IsFieldLengthMax, CalculateFields

Correct Answer: DSection: Topic 1Explanation

Explanation/Reference:

QUESTION 59What is the name of the utility that is used for batch maintenance?

A. NENU ProfileB. Datacap StudioC. NENU ManagerD. Application Manager

Correct Answer: CSection: Topic 1Explanation

Explanation/Reference:

Page 24: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

QUESTION 60A company has development, QA, and production environments. They want to use the VScan actionSetSourceDirectory to input files from different directories for each system.What would be the recommended solution?

A. Write a custom action for them.B. Type the directory to be read from as the parameter of the actionC. Use a @APPPATH smart parameter to read the directory from the .app file.D. Use the @LocalEnvironment smart parameter to read which environment they are currently using.

Correct Answer: CSection: Topic 1Explanation

Explanation/Reference:

QUESTION 61An IBM Datacap Taskmaster Capture developer has created a custom DotEdit verify panel namedAPT_Main_Panel in Taskmaster V8.1. They want the custom panel to be displayed for each page of typeMain_Page. The form has already been created, compiled, and the dll has been configured correctly. Whattask setting needs to be modified to display the custom panel?

A. In the dialog's DotEdit section, add a new bind entry and set:Panel for = "Main_Page"value = "APT_Main_Panel"

B. In the dialog's DotEdit section, add a new bind entry and set:Panel for = "APT_Main_Panel"value = "Main_Page"

C. In the dialog's Custom web panels section, check the "Use custom web panels" box and add a new bindentry and set:Panel for = "Main_Page"value = "APT_Main_Panel"

D. In the dialog's Custom web panels section, check the "Use custom web panels" box and add a new bindentry and set:Panel for = "APT_Main_Panel"value = "Main_Page"

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:

QUESTION 62A company is designing forms for both scanning and faxing. The majority of the input is going to be handprinted recognition Which of the following should be recommended?

A. Dotted constraint boxes.B. Solid black constraint boxes.C. Solid red drop-out constraint boxes.D. Well marked areas with OCR/C set to unconstrained hand print.

Correct Answer: ASection: Topic 1Explanation

Explanation/Reference:Topic 2, Volume B

Page 25: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

QUESTION 63A solution designer is creating an application for a customer. Part of the requirements are to look up datafrom a database. The customer also has OMR fields. What are some of the field level variables you mightexpect to be used in the DCO to accomplish this?

A. MAX, MIN, ORDERB. DOC, PAGE, FIELDC. DICT, SELECT, LOOKUPD. NAME, ADDRESS, NUMBER

Correct Answer: CSection: Topic 2Explanation

Explanation/Reference:

QUESTION 64A healthcare company is deploying IBM Datacap Taskmaster Capture in three geographic locations. Indexverification operators will process batches scanned in the same location they reside. To handle spikes involume, index operators from other locations will need to assist in processing the back log. Additionally, theIBM Datacap Taskmaster Capture administrators require all roles be centrally managed. Which componentplacement scenario would provide the best performance for the local verification operators and still allowout of location operators to process batches when necessary?

A. Place a Taskmaster server, Taskmaster Web server, file store centrally and Rulerunner in eachgeographic locations.

B. Place a Taskmaster Web server in all geographic locations and a file store, Rulerunner and Taskmasterserver in the central state.

C. Place a Taskmaster Web server, file store and Rulerunner in all geographic locations and a Taskmasterserver in the central state.

D. Place a Taskmaster Web server, and Taskmaster server in the central geographic location and a filestore and Rulerunner in each geographic locations.

Correct Answer: CSection: Topic 2Explanation

Explanation/Reference:

QUESTION 65An IBM Datacap Taskmaster Capture application handles a variety of page types that are very similar. Themain difference between the pages are their graphics. Select two that show how graphics can be used?

A. To identify a page.B. To aid in RotateImage().C. To determine the language for the page.D. Compensate for image misalignment and scaling.E. Graphics are not candidates for identifying pages.

Correct Answer: ADSection: Topic 2Explanation

Explanation/Reference:

QUESTION 66The diagram below illustrates jobs configured in a sample workflow:

Page 26: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

Which of the following properly identifies the spawn type for labels A and B?

A. Label A: Jump, Label B: SplitB. Label A: Split, Label B: JumpC. Label A: Split, Label B: BranchD. Label A: Branch, Label B: Split

Correct Answer: DSection: Topic 2Explanation

Explanation/Reference:

QUESTION 67During a validation task profile, it is common to see Status_Preserve_OFF at the page level. What is thepurpose and effect of this action?

A. It sets field statuses to 1 so that they can be reset to 0 if a field fails a rule.B. It skips fields during the validation ruleset that have their status set to 49 prior to entering the ruleset.C. It sets the statuses of the page and fields to 0, and if a field returns false, it sets the page status to 1.D. It ensures that no values can be overwritten by standard actions, however, custom actions can still

change field values.

Correct Answer: CSection: Topic 2Explanation

Explanation/Reference:

QUESTION 68The solution designer is tasked to build an IBM Datacap Taskmaster Capture application based on theFastApp application. What is a best practice before creating the custom application?

A. Login as an Administrator.B. Copy and rename the application.C. Pre-scan the images using FastDoc in local mode.D. Set the FastDoc client to FastApp mode on the settings page.

Correct Answer: BSection: Topic 2Explanation

Page 27: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

Explanation/Reference:B must be correct because the other three have nothing to do with creating a new application from anexisting one.

QUESTION 69The following is found in an application the solution designer is troubleshooting:

RecogOMRThreshold(14,10)

Also, the area designated as the recognition area has a darkness of 12%. What value would the solutiondesigner expect to find after recognition is complete?

A. 1, with low confidenceB. 0, with low confidenceC. 1, with high confidenceD. 0, with high confidence

Correct Answer: BSection: Topic 2Explanation

Explanation/Reference:Because the pixel percent (darkness) is below the threshold, it is considered not selected (0). Confidenceis low because it's also way below the high threshold and outside of the range.

QUESTION 70An IBM Datacap Taskmaster developer needs to implement a new task profile that runs under theRulerunner service. The developer has already created the task profile, ruleset, DCO mapping, job task andtested it manually to ensure it runs correctly. What two steps are required to run the job:task underRulerunner?

A. Use IBM Datacap Rulerunner Manager to add a new thread and assign the job:task to the thread.B. Use IBM Datacap tmweb to enable the checkbox next to the job:task under the Rulerunner shortcut.C. Use IBM Datacap Taskmaster Application Manager to add the task to the application's Rulerunner tab.D. Use IBM Datacap Studio's thread setup panel to add a new thread and assign the job:task to the thread.E. Modify the datacap.xml file with a Rulerunner attribute on the application's node and create a child node

for each task that Rulerunner should execute.

Correct Answer: ACSection: Topic 2Explanation

Explanation/Reference:Since it's already created, all you need to do is tell Rulerunner what it's now doing. You do that by firstadding it in Rulerunner, then attach it to the application.

QUESTION 71The framework generated by the Application Wizard exports all captured data to a text file located in theapplication's export folder. The default Export ruleset includes two rules.What are the two included rules?

A. CloseExportFileB. Export SubFieldC. Set Export ParamsD. Export Page FieldsE. ExportLastSubField

Correct Answer: CDSection: Topic 2Explanation

Page 28: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

Explanation/Reference:The trick on this one is the naming convention. We're not exporting individual fields nor are we closing thefile when we haven't exported it yet.

QUESTION 72Which of the following is NOT a supported file type in the Convert library?

A. ZIPB. Microsoft WordC. Multi-page TIFFD. Microsoft PowerPoint

Correct Answer: DSection: Topic 2Explanation

Explanation/Reference:PowerPoint isn't a convertible format in applications. Images can be converted to Word, TIFF, PDF or ZIP,in general.

QUESTION 73When building an application using IBM Datacap Studio tool, the rulesets/rules are associated to the page,document, batch, or field level. What is the flow of processing in the DCO?

http://www.gratisexam.com/

A. Field, Page, Document, Batch.B. Document, Page, Field and Batch.C. Batch, Document, Page and Field.D. Page and Field, Batch and Document.

Correct Answer: CSection: Topic 2Explanation

Explanation/Reference:You can see this in the DCO window. The batch is the highest level, then document (type), then pageswithin each document (type), then fields on each page.

QUESTION 74Default jobs are generated automatically by the IBM Datacap Studio Application Wizard. Sometimes,however, jobs will need to be created to handle specific conditions. What items are required to create avalid job?

A. A job definition with at least one task and a rule associated with each task.B. A job definition with at least one task and a ruleset associated with each task.C. A program with at least one task and a job definition associated with each task.D. A job definition with at least one task and a program associated with each task.

Correct Answer: DSection: Topic 2Explanation

Page 29: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

Explanation/Reference:D is correct because, unlike A and B, you need to associate the job with a program. The job is the highestlevel of interaction; a program is only a configuration that doesn't do anything without a job to execute it.

QUESTION 75An IBM Datacap Taskmaster developer is customizing the layout for the Verifine.aspx page. The clientwants the batch view panel in top right, data fields panel in top left, and image view panel to span acrossthe bottom.

Based on the VeriFine layout interface:

Which of the following configuration values would accomplish this layout?

A. Image View target = 1, Data Entry Panel target = 2, Batch View target = 3B. Image View target = 4, Data Entry Panel target = 3, Batch View target = 2C. Image View target = 4, Data Entry Panel target = 2, Batch View target = 3D. Image View target = 1, Data Entry Panel target = 5, Batch View target = 7

Correct Answer: CSection: Topic 2Explanation

Explanation/Reference:Layout window is pretty self-explanatory, but "single view" means only one object, "double views" meanstwo objects side-by-side, and "side by side" means more than two side-by-side.

QUESTION 76An IBM Datacap Taskmaster solution needs to read a single 3 of 9 barcode off of a form. Occasionally anincorrect value is returned. In one instance, the form had 452843 in a 3 of 9 format, but the barcode read asR2GUYZ. There appears to be only one barcode on the page. How would you go about solving theproblem?

Page 30: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

A. Set up the barcode engine to read only 3 of 9 barcodes.B. Set up the barcode engine to read numeric characters only.C. Check your imagefix. It may be removing lines from the barcode. Adjust as necessary.D. The barcode read upside down. Check the image orientation and use autorotate to correct the problem.

Correct Answer: ASection: Topic 2Explanation

Explanation/Reference:It's possible the engine is reading the 3 of 9 as a Code 128, which while it may look somewhat similar,might yield a different value completely. Constraining the engine to only look for 3 of 9 gets around this.

QUESTION 77An engineering company has remittances that are always two pages. What is the best page identificationmethod to use in IBM Datacap Taskmaster?

A. FlexIDB. Text matchingC. Manual page identificationD. Structure-based identification

Correct Answer: DSection: Topic 2Explanation

Explanation/Reference:D is correct because structure-based identification yields the fastest performance; it always knows howmany pages to expect and what to identify on each, without change.

QUESTION 78A form processing facility identifies the first page of each tax return by the existence of a tax payer ID valuein the format aaaaa-nnnnn-aaaaa next to the Tax Payer ID label. Depending on the quality of the receivedform it is common for one of the hyphens to be removed by ImageFix. What method of finding data wouldbe the most efficient and reliable way to identify the main page?

A. FindDBList()B. RegExFind()C. FindKeyList()D. WordFind()

GoWordRight()

Correct Answer: BSection: Topic 2Explanation

Explanation/Reference:B is the right answer only because RegEx is the most flexible when trying to locate the value. It's also theonly way of the three to test a value that isn't known by any existing database.

QUESTION 79A particular IBM Datacap Taskmaster application needs to check dates to see if they are a valid format, andthen reformat the date to another format (if necessary). The machine's locale is set to US_EN, and the ruleis: IsFieldDate() IsFieldDateWithReformat(yyyy-mm- dd) When this validation rule runs prior to verification,it seems to operate fine and the date looks to be formatted properly in verification. DotEdit does not initiallydisplay an error on this field. However, when the form is submitted, the field fails validation. What would bea recommended fix?

A. Set the field to non-overridable.B. Add ReplaceChars(-,/,*) before the IsFieldDate.

Page 31: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

C. Add SetFieldStatus(0) behind the IsFieldDateWithReformat.D. Mark the field in DStudio to prevent re-running the validation rule on it.

Correct Answer: BSection: Topic 2Explanation

Explanation/Reference:B is correct because when validating against a US locale, the workstation client will look for slashes in thedate value by default. ReplaceChars(-,/,*) is telling the engine to transform the value into a locale-friendlyone before performing the validation after verification.

QUESTION 80Which method can be used to archive the RV2 'Current Batches' report on a daily basis?

A. Select the 'Current Batches' report and select the Save As link to save as an XML file.B. Execute the 'Current Batches' report and select the PDF link to save as a PDF document.C. Execute the 'Current Batches' report and select the HTML link to save as an HTML document.D. Select the 'Current Batches' report and select the Word link to save as an MS Word document.

Correct Answer: BSection: Topic 2Explanation

Explanation/Reference:B is the only way to create an "archive" or unalterable format for the report. This is somewhat of a trickquestion.

QUESTION 81A system administrator has setup an IBM Datacap Taskmaster architecture where security rightsassignment is an important factor. Which best describes what rights a user will have?

A. The user will have all rights granted through user, group membership, or station level.B. The user will have all rights granted through user or group membership, then permissions are filtered

based on station.C. The user will have only rights granted to both user and group membership, then permissions are filtered

based on station.D. When rights are specifically granted to a user, rights assigned through group membership are ignored.

The user permissions are then filtered based on station.

Correct Answer: BSection: Topic 2Explanation

Explanation/Reference:Standard security permission practice. The user/group membership gets you to the application, theapplication/station determines what you can do when you're inside.

QUESTION 82A customer has a remittance number printed on their forms. This remittance number is an Alpha character,followed by 7 digits What is the correct picture string for this validation?

A. AXXXXXXXB. C#######C. ANNNNNNND. CDDDDDDD

Correct Answer: CSection: Topic 2Explanation

Page 32: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

Explanation/Reference:Standard character syntax. "A" means alphanumeric, "N" means numeric only.

QUESTION 83A utility company requires all customer correspondence to be archived in their Document ManagementSystem. The bulk of these documents are received via RightFax server and need to be imported into IBMDatacap Taskmaster document batches for further processing. It is also required that the solution designerconfigure the ingestion rule to delete images in RightFax server after they are imported. What is the correctsequence of actions that would accomplish this requirement?

A. SetServerName("hostname") > SetUserID("userid") > SetUserPassword("password") > SetProtocol("4")> Connect() > SetFaxRemoval(True) > ImportFaxes() > Disconnect()

B. SetServerName("hostname") > SetUserID("userid") > SetUserPassword("password") > SetProtocol("4")> Connect() > ImportFaxes(True) > DeleteFaxes(true) > Disconnect()

C. SetServerName("hostname") > SetUserID("userid") > SetUserPassword("password") > SetProtocol("4")> Connect() >SetFaxRemovalAfterImport(True) > ImportFaxes() > Disconnect()

D. SetServerName("hostname") > SetUserID("userid") > SetUserPassword("password") > SetProtocol("4")> Connect() > ImportFaxes() >SetFaxRemovalAfterImport(True) > Disconnect()

Correct Answer: CSection: Topic 2Explanation

Explanation/Reference:C is correc,t rather than D, because you have to set the flag to remove before doing the import.

A and B are incorrect because they have incorrect functions.

QUESTION 84A solution designer has been requested by the customer to identify various content repositories supportedby the IBM Datacap Taskmaster export process. Which of the following repositories is not supported?

A. IBM FileNet Image Services 4.2B. Microsoft SharePoint Server 2007C. IBM FileNet Content Manager 4.5.1D. OpenText Livelink Enterprise Server 9.7

Correct Answer: BSection: Topic 2Explanation

Explanation/Reference:BE CAREFUL ON THIS ONE!!!! The question doesn't specify version, but it refers only to Datacap 8.0.1. Sharepoint Server 2007 with MOSS is supported in Taskmaster Capture 8.1.

http://datacap.wordpress.com/2012/02/03/hardware-and-software-requirements-for-ibm-datacap-taskmaster-capture-version-8-0-1/

QUESTION 85A wholesale company has invoices sent to them via fax as well as through regular mail. Both invoices arepaper documents. When scanned into the IBM Datacap Taskmaster system, what are the differencesbetween a faxed image and printed image?

A. Faxed images are cleaner than printed images.B. Faxed images usually have less content than printed images.C. Fax line present on top of image, and content can seem compressed.D. Printed images and fax images are the same in terms of clarity and compression.

Page 33: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

Correct Answer: CSection: Topic 2Explanation

Explanation/Reference:C is correct because faxes are always degraded in comparison to printed images, even though it's thesame document with the same content.

QUESTION 86A solution designer has been asked to determine and document if an action library is available to supportthe ingestion of image file attachments from a Microsoft Exchange server. Which of the two following actionlibraries could the solution designer chose?

A. IMailB. EX_MailC. EWSmailD. SendEMailE. ex_EMLOption

Correct Answer: ACSection: Topic 2Explanation

Explanation/Reference:http://www-01.ibm.com/support/knowledgecenter/SSZRWV_8.1.0/com.ibm.dc.develop.doc/dcadg689.htm

QUESTION 87A solution designer is setting up connector actions to upload documents to a OpenText Livelink server.Which of the following is the correct sequence of valid actions that needs to be added to the Export ruleset?

A. SetPort_LL()SetServerName_LL()SetUserID_LL()Upload_LL()Terminate_LL()

B. SetServerName_LL()SetPort_LL()SetUserID_LL()SetUserPassword_LL()Connect_LL()Upload_LL()Exit_LL()

C. SetServerName_LL()SetUserID_LL()SetPort_LL()SetUserPassword_LL()Connect_LL()Upload_LL()Terminate_LL()

D. SetServerName_LL()SetUserID_LL()SetUserPassword_LL()SetPort_LL()Connect_LL()Upload_LL()Disconnect_LL()

Correct Answer: DSection: Topic 2Explanation

Explanation/Reference:

Page 34: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

http://www-01.ibm.com/support/knowledgecenter/SSZRWV_8.1.0/com.ibm.dc.develop.doc/dcadg754.htm

QUESTION 88A customer has paper documents that have data which needs to be extracted automatically, validated, andsent to a repository. What is a critical item that may cause issues for paper documents processed by theIBM Datacap Taskmaster solution?

A. Font style and size.B. Number of words on page.C. Content of the data on page.D. Number of barcodes on page.

Correct Answer: ASection: Topic 2Explanation

Explanation/Reference:A is correct because certain OCR engines have trouble when the font is too large, too small, or of a non-standard type. Note that this only applies on paper because the engine has to "guess" the font from thepixel shape. PDFs and other types where the fonts may be embedded don't have this challenge.

QUESTION 89A system administrator needs to setup a distributed client/server environment where the datacap.xmlconfiguration file and application files are stored on a shared location. Which two of the following answersare correct?

A. The Taskmaster server should have a local copy of each application's dco file.B. The datacap.xml file should point to the full UNC path where the datacap application files are located.C. References to applications that are unused or not configured should be removed from the datacap.xml

file.D. Each user account must have read/write access to the datacap.xml file and each referenced application

directory.E. The local datacap.xml file should be removed from each station because the local configuration file

takes precedence.

Correct Answer: BCSection: Topic 2Explanation

Explanation/Reference:More information:

http://pic.dhe.ibm.com/infocenter/datacap/v8r1m0/index.jsp?topic=%2Fcom.ibm.dc.install.doc%2Fdcane013.htm

As a side note, the key here is "shared location" and "client/server environment". That disqualifies A, D andE automatically. C is to avoid errors when launching the tool.

QUESTION 90Which of the following is a feature found in APT?

A. 837 outputB. Return FilingC. Managed RecognitionD. Dynamic Screen Resolution

Correct Answer: CSection: Topic 2Explanation

Page 35: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

Explanation/Reference:C is correct.

The easy way to know it's correct: the others don't apply to Accounts Payable. 837 is an EDI format mostlyused for healthcare. Return filing applies to tax forms. Dynamic Screen Resolution has nothing to do withDatacap. Thus it can only be C: Managed Recognition.

QUESTION 91A customer is currently in production with a IBM Datacap Taskmaster Capture application. Theadministrator would like to know where the information is stored concerning users who cannot logon to acustom Taskmaster application. What database, table, and column contains this information?

A. Admin Database > audit table > au_status columnB. Engine Database > qstats table > qs_start columnC. Engine Database > debug table > db_status columnD. Admin Database > lastjob table > lj_user_ind column

Correct Answer: ASection: Topic 2Explanation

Explanation/Reference:A is correct.

B isn't correct because qstats holds general batch statistics, not user information.C isn't correct because it contains batch information that went to an exception flow. For example, manuallydeleted batch data. It holds no user information.

D isn't correct because there is no lastjob table in Datacap.

QUESTION 92A tax processing center uses the provided RV2 reports to monitor batch jobs. Management has requesteda single custom report be created showing both scan and verify task statistics. Which IBM DatacapTaskmaster Capture database tables will need to be queried to create the report?

A. qstats and queueB. qstats and scan2kstC. scan2kst and de2kstD. taskstats and de2kst

Correct Answer: CSection: Topic 2Explanation

Explanation/Reference:C is correct.

A isn't correct because qstats and queue hold general batch information.B isn't correct because qstats holds general batch information.D isn't correct because taskstats holds Vscan and background (i.e. non-interactive) task information.

QUESTION 93The client's hardware requirements outline that up to 125 concurrent IBM Datacap Taskmaster CaptureWeb users will need to be supported for their application. Which statement is true in determining theTaskmaster web server capacity?

A. A maximum capacity does not exist. User capacity is determined by the hardware of the server.B. The maximum capacity for a Taskmaster Server is 35. Four Taskmaster servers should be installed.C. The capacity range for a Taskmaster Web Server is 50 to 100 users. Two Taskmaster web servers

should be installed.D. The capacity range for a Taskmaster Web Server is 25 to 50 users. Three Taskmaster web servers

Page 36: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

should be installed.

Correct Answer: CSection: Topic 2Explanation

Explanation/Reference:IBM RedBook: "Implementing Imaging Solutions with IBM Production Imaging Edition and IBM DatacapTaskmaster Capture", SG24-7969-00, page 417.

QUESTION 94Invoices which identified correctly in the past, using fingerprinting, are no longer being identified.

Referencing the screenshot of the Fingerprint Maintenance Tool, which Fingerprint is a candidate forcausing this type of behavior?

A. Fingerprint 1003B. Fingerprint 1039C. All fingerprints are invalid.D. This tools does not provide enough information to help resolve the issue.

Correct Answer: CSection: Topic 2Explanation

Explanation/Reference:C is correct because the fingerprint isn't effective without all required pieces: the TIFF that created thefingerprint, the fingerprint CCO, the XML, the database reference and a DCO batch or page reference.

QUESTION 95A consultant is asked to diagram a high level communication architecture diagram of IBM DatacapTaskmaster Capture and it's clients. What type of communication is used to access files in the batches?

A. OLE DBB. Datacap Taskmaster client protocolC. Datacap Taskmaster socket protocolD. Common Internet File System (CIFS)

Correct Answer: DSection: Topic 2Explanation

Explanation/Reference:In other words, plain old file share access, either DFS, local drive, UNC, etc.

Page 37: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

QUESTION 96A solution designer is reviewing a rough draft of the tasks configured in job XYZ to determine the properRulerunner thread configuration. The XYZ job contains a vscan batch creation task. What queuing modesetting is recommended for the Rulerunner server assigned to execute the XYZ job?

A. List mode offB. Active-active mode offC. Mixed queuing mode offD. Sequential queuing mode off

Correct Answer: CSection: Topic 2Explanation

Explanation/Reference:C is correct. Ironically, this is due to how Rulerunner is designed to work vs. Rulerunner Server. TheRulerunner engine, when called by VScan, can actually work "too fast" for the Server to keep up; thus IBMrecommends that you run the batches sequentially.

http://www-01.ibm.com/support/docview.wss?uid=swg21618564

A isn't correct because how the batches display has nothing to do with how they process.

B isn't correct because it refers to load balancing, which has nothing to do with how Rulerunner procesesthe batches. It also has nothing to do with Vscan calling Rulerunner.

C isn't correct because there is no such setting.

QUESTION 97Which of the following is the minimum hardware recommended to operate an IBM Datacap TaskmasterWeb server?

A. Intel Core 2 Duo E6850 (3.0 GHz) AMD Athlon or Sempron 2 GB Ram, 80 GB DiskB. Intel Core 2 Duo E6850 (3.0 GHz) AMD Athlon or Sempron, 4 GB RAM, 80 GB DiskC. Intel Core 2 Duo T7500 (2.20 GHz) AMD Opteron, Athlon or Sempron, 3 GB Ram, 100 GB DiskD. Pentium Dual Core E2160 (1.80 GHz) AMD Opteron, Athlon, or Sempron Opteron,1 GB Ram, 10 GB

Disk

Correct Answer: BSection: Topic 2Explanation

Explanation/Reference:http://www-01.ibm.com/support/docview.wss?uid=swg27022094#MSR

As a side note, D is silly since the OS alone requires 1GB of RAM.

QUESTION 98An enterprise is utilizing a computing environment in which the infrastructure resides at one location. Whatis the name of this IBM Datacap Taskmaster Capture deployment model?

A. Private DeploymentB. IBM Smart DeploymentC. Centralized DeploymentD. Private Managed Deployment

Correct Answer: CSection: Topic 2Explanation

Page 38: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

Explanation/Reference:This is standard client/server terminology.

A, B and D are all incorrect because there is no special name for this type of infrastructure for anyapplication.

QUESTION 99An IBM Datacap Taskmaster administrator needs to setup a Verify task profile that can be completedthrough tmweb's Verifine interface or the thick client DotEdit interface. Which value should be selected forthe task's "Program" parameter?

A. NoneB. DotEditC. MultipleD. Rulerunner

Correct Answer: CSection: Topic 2Explanation

Explanation/Reference:C is correct.

A isn't correct because you do need to tell the system what "Program" will be performing the task.B isn't correct because DotEdit isn't the only interface that will be doing the work.D isn't correct because RuleRunner doesn't do Verify; Verify is a user interactive task.

QUESTION 100A solution designer is attempting to implement FastDoc. The criteria is to have minimized impact to IBMDatacap Taskmaster Server and allow the user community to run batches locally. What are the threemodes that FastDoc Capture can be run in and which mode BEST fits the user community's needs?

A. Scan,Taskmaster, Local and Remote with Taskmaster mode option.B. Remote, Taskmaster, Scan and Remote with Scan and Remote mode option.C. Local, Taskmaster, Local and Taskmaster with Local and Taskmaster mode option.

http://www.gratisexam.com/

D. Remote, Taskmaster, Local and Taskmaster with Local and Taskmaster mode option.

Correct Answer: CSection: Topic 2Explanation

Explanation/Reference:C is correct.

A isn't correct because "Scan" is not a FastDoc mode, it's a button.B and D aren't correct because any "Remote" work will impact the Taskmaster Server.

QUESTION 101A solution designer has to configure Rules for an invoice billing application that will create the export file tobe consumed by IBM Content Manager On-Demand (CMOD). Export rules are created and connected tothe DCO in the DCO tab of the Datacap Studio. A Export File Header needs to be attached to which eventat the batch level in the DCO?

Page 39: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

A. OpenB. BeginC. InitializeD. Process

Correct Answer: ASection: Topic 2Explanation

Explanation/Reference:A is correct. I consider this a trick question.

B, C, and D are all incorrect because in DCO, you only have Open. Begin, Initialize, and Process refer toactually doing the work and don't appear in the DCO.

QUESTION 102A developer is placing an action on a field to copy the value of a batch level variable named StartTime tothe field value for later export. Which action and parameters would be most appropriate for this task?

A. rrSet("@B.StartTime","@TEXT")B. rrSet("@TEXT","@B.StartTime")C. rrCopy("@B.StartTime","@TEXT")D. rrCopy("@TEXT","@B.StartTime")

Correct Answer: ASection: Topic 2Explanation

Explanation/Reference:A is correct.

B isn't correct because rrSet() is a From / To action (the values are reversed).C and D aren't correct because rrCopy() is for copying field data. Batch variables aren't fields.

QUESTION 103A consultant, while developing an IBM Datacap Taskmaster financial application, must incorporatevalidation rules to enforce certain fields to be in valid currency format and needs to follow these rules:1).Always delete Alpha characters from the field, so if the field has 'USD' or '$' as suffix, this will be deleted.2).Remove leading or trailing spaces from the field 3).Always ensure the field is numeric. 4).Should alwaysinclude two digit decimal amount Which of the following validation functions could be performed at the DCOfield level to meet these requirements in that order ?

A. DeleteAllAlpha() > DeleteLCSpaces() > IsFieldCurrency()B. DeleteAlpha() > DeleteSelectedChars() > IsFieldCurrency()C. DeleteAlpha() > DeleteAllMiscChars() > IsFieldLocalCurrency()D. DeleteAllAlpha() > FilterFieldSelectedChars() > IsFieldCurrency()

Correct Answer: DSection: Topic 2Explanation

Explanation/Reference:D is correct. See the link at the bottom for more information and the table of validations.

A isn't correct because DeleteLCSpaces() is used to delete low confidence spaces from a field's captureddata.

B and C aren't correct because there is no such validation as "DeleteAlpha()".

Page 40: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

http://www-01.ibm.com/support/knowledgecenter/SSZRWV_8.1.0/com.ibm.dc.develop.doc/dcadg628.htm

QUESTION 104A customer has configured their IBM Datacap Taskmaster server to use ADSI authentication. What needsto be done to the RuleRunner server for it to run properly with ADSI authentication?

A. Using the Rulerunner Manager, set up each instance of Rulerunner server to use TaskmasterAuthentication.

B. Ensure that at least one domain/Windows account exists for the Datacap Taskmaster Server Servicecan use. Use the Rulerunner Manager, then set up each instance of Rulerunner to use WindowsAuthentication.

C. Ensure that at least one domain/Windows account exists, and that the Windows account is part of thecorrect Taskmaster-specific AD security group. Use the Rulerunner Manager, then set up each instanceof Rulerunner server to use Taskmaster Authentication.

D. Ensure that at least one domain/Windows account exists for the Datacap Rulerunner Service can use,and that the Windows account is part of the correct Taskmaster-specific AD security group. Use theRulerunner Manager, then set up each instance of Rulerunner to use WindowsAuthentication.

Correct Answer: DSection: Topic 2Explanation

Explanation/Reference:D is correct. Be careful with this one.

A isn't correct because Taskmaster Authentication isn't ADSI authentication.B isn't correct in this example because it assumes a new setup, where the domain credential has not yetbeen added to a security group that has the proper access.C isn't correct in this example because if Rulerunner Server is using Taskmaster Authentication, despitehaving a Windows credential set up, you're still not using ADSI authentication.

QUESTION 105A solution designer is creating a custom action and needs to write debugging information for analysis. WhatIBM Datacap Taskmaster function could be called to accomplish this?

A. RRSLogB. WriteLogC. InsertLineD. WriteToFile

Correct Answer: BSection: Topic 2Explanation

Explanation/Reference:B is correct.

A isn't correct because it's only logging Rulerunner rule set activities and you can't add custom actions to it.C and D aren't correct because InsertLine() and WriteToFile() are reserved for text file modification. While you could in theory create a custom text file, it's a waste to write extensive code when WriteLog()already does the work.

QUESTION 106A solution designer is creating a custom action in C# for IBM Datacap Taskmaster Capture. In addition tocreating the RRX file, what is required to create a C# action?

A. Create a DLL.B. Create and register a DLL.C. The use of multiple string parameters.

Page 41: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

D. Associate the C# file with a DCO object.

Correct Answer: BSection: Topic 2Explanation

Explanation/Reference:This is standard Visual Studio stuff, but...

B is correct.

A isn't correct because just having a custom DLL doesn't do anything. It needs to have an entry point andmust be registered on the server or workstation executing the code.C isn't correct because strings don't do anything by themselves. They need code to use the strings.D isn't correct because you can't directly reference a C# file in anything (not just Datacap). It has to becompiled code for runtime execution (i.e. a DLL, an EXE, etc.)

QUESTION 107A solution designer has developed an IBM Datacap Taskmaster Capture application that checks for abarcode on a page and sets the page type.

Given the above rule, what is the page type if no barcode is found?

A. Bus_TicketB. Air_ReceiptC. Cruise_ItineraryD. Rental_Agreement

Correct Answer: ASection: Topic 2Explanation

Explanation/Reference:A is correct, because rrCompareNot() identifies situations when the barcode isn't located, or for which thevalue doesn't match the one specified for that page type.

Note that there is one document type and three possible page types in this transaction.

B isn't correct because SetDCOType() references the document type, not the page. Also it's checking fora barcode flag, which implies a barcode must be read/readable.C isn't correct because it will only execute if we're not looking for a barcode or haven't found one on thepage we're on.D isn't correct because it says that we're setting that value if we DO find a barcode matching the value.

QUESTION 108A developer plans on adding several new task profiles to their IBM Datacap Taskmaster application. Beforethey add the task profile they would like to have a backup copy of the file which contains this information. Inwhat file is this information stored?

Page 42: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

A. datacap.xmlB. collection.xmlC. <appname>.appD. <appname>.xml

Correct Answer: BSection: Topic 2Explanation

Explanation/Reference:B is correct.

A isn't correct because datacap.xml contains application information only, not task profiles.C isn't correct because the .app files are application schemas that are referenced by datacap.xml.D isn't correct because the other .xml files for each application are settings for the application, notconfigured task information.

QUESTION 109A solution designer has created a rule to perform image enhancement.

Given the above rule, what is the image enhancement doing?

A. Performing image enhancement using .tio as an enhancement templateB. Calling the image enhancement routine using the .tio enhancement optionC. Performing image enhancement and creating an enhanced image with a filetype of .tioD. Performing image enhancement, creating a new image enhanced file and renaming the source file with

a .tio extension.

Correct Answer: DSection: Topic 2Explanation

Explanation/Reference:FYI, it isn't clear from the function or from IBM's source site (below), but ImageEnhance has a string thatrequests the extension for renaming the source file so that it's recognizable from the enhanced file.

http://pic.dhe.ibm.com/infocenter/datacap/v8r1m0/topic/com.ibm.dc.develop.doc/dcadg176.htm

QUESTION 110A customer would like to update the demo TravelDoc so that users can only use the Web Client to virtuallyscan into the workflow "Main Job".

Page 43: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

For users to be able to run the task in the operations tab "Web VScan" link in Taskmaster web client whatdoes one have to do in the Administrators workflow and shortcuts tab?

A. In the workflow tab set the task VScan program to "DotScan"; In the shortcut tab set "Web VScan"permissions for "Web Job"/"iVScan".

B. In the workflow tab set the task VScan program to "RuleRunner"; In the shortcut tab set "Web VScan"permissions for "Web Job"/"iVScan" and "Main Job"/"Verify".

C. In the workflow tab set the task VScan program to "Verifine.aspx"; In the shortcut tab set "Web VScan"permissions for "Web Job"/"iVScan" and "Web Job"/"Verify".

D. In the workflow tab set the task VScan program to "VScancl.aspx"; In the shortcut tab set "Web VScan"permissions for "Web Job"/"iVScan" and "Main Job"/"VScan".

Correct Answer: DSection: Topic 2Explanation

Explanation/Reference:More information:

http://pic.dhe.ibm.com/infocenter/datacap/v8r1m0/topic/com.ibm.dc.develop.doc/dcadg449.htm

QUESTION 111If an IBM Datacap Taskmaster Server fails, any tasks that are processed by clients connected to that serverare abandoned in the running state. When configuring NENU manager what can be done to restorebatches to a proper status?

A. A Batch PurgeB. A Batch ResetC. A Batch ProfileD. A Batch Priority Update

Correct Answer: BSection: Topic 2Explanation

Page 44: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

Explanation/Reference:B is correct. A batch reset forces the server to reset the batch status to the previously executed one - likebacking up slightly if you're not able to get into a parking spot.

A isn't correct because that would delete the batch!C isn't correct because a batch profile has nothing to do with status or actions. It's a descriptor.D isn't correct because if a batch has stalled due to a server issue, changing its priority won't do anythinguntil and unless you do B.

QUESTION 112A developer uses IBM Datacap Studio's Application Wizard and selects the option to create "a new RRSapplication", then provides an application name and accepts the defaults. Which of the following is correctabout the created application?

A. The workflow includes three job types: Main Job, FixUp Job, and Web Job.B. The Profiler task profile is added to the Rulerunner's default thread <thread0>.C. There are no entries on the fingerprint database / IBM Datacap Studio zones tab.D. The job type "Main Job" includes: VScan, Upload, PageID, Profiler, Verify, and Export.

Correct Answer: ASection: Topic 2Explanation

Explanation/Reference:A is correct.

B isn't correct because that profile already exists in the default thread.C isn't correct because fingerprints/zones have nothing to do to with Rulerunner rule sets (the rule set mightexecute a fingerprint search, but that's defined manually after the fact in Studio).D isn't correct because it applies to the Web, not to Studio.

QUESTION 113A IBM Datacap Taskmaster Capture solution designer wants to add a company's logo to the default DotEditpanel. How is this achieved in Visual Studio?

A. With the DCEdit control.B. With the DCLogo control.C. With a PictureBox control.D. With the PictureImage control.

Correct Answer: CSection: Topic 2Explanation

Explanation/Reference:Standard Visual Studio control.

DCEdit and DCLogo refer to other pre-existing objects.

PictureImage isn't a real control.

QUESTION 114A developer is migrating an IBM Datacap Taskmaster Capture application from V8.0.1 to 8.1 using theApplication Migration tool. Part of the upgrade process updates the Admin, Engine, and Fingerprintdatabases to the 8.1 format. The existing application uses a Microsoft Access database and they wish tocontinue using Microsoft Access after the upgrade. Which of the following reflects the target databases forthe Application Migration tool?

A. The Application Migration tool will backup the current Microsoft Access databases and upgrade theexisting database files during the upgrade.

B. The Application Migration tool will create new Microsoft Access databases and update the Datacap

Page 45: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

application's .app file to use the new databases.C. The Application Migration tool needs new Microsoft Access database templates in the 8.1 format, which

can be copied from the AppWizard directory.D. The Application Migration tool needs empty Microsoft Access databases, which can be created using

Microsoft Access by selecting File > New > Blank database.

Correct Answer: CSection: Topic 2Explanation

Explanation/Reference:See below for more information:http://pic.dhe.ibm.com/infocenter/datacap/v8r1m0/topic/com.ibm.dc.develop.doc/dcadv000.htm

QUESTION 115What's the main purpose of the QA tab in IBM Datacap Taskmaster Capture Administrator area?

A. Allows an administrator to monitor user's behavior.B. Configures users and permitted tasks for each user.C. Allows an administrator to specify quality assurance jobs based on groups and tasks.D. Configures the batch selection mode for the quality assurance jobs based on groups tasks and

shortcuts permissions.

Correct Answer: CSection: Topic 2Explanation

Explanation/Reference:Right AnswerC: The QA tab holds settings for quality monitoring at a group and/or task level. For example, if a certaindocument type requires a second validator due to the number of fields (i.e. "double blind"), the adminstratorcan force a quality assurance review and reindex step.

QUESTION 116A solution designer needs to export to Microsoft SharePoint with a FastDoc application.Which column type is not supported?

A. Date columnsB. Choice column.C. Currency columnsD. Single line of text columns with maximum number of characters

Correct Answer: BSection: Topic 2Explanation

Explanation/Reference:Right AnswerB: Choice column isn't supported for Sharepoint. See below for more information.

http://pic.dhe.ibm.com/infocenter/datacap/v8r1m0/topic/com.ibm.dc.admin.doc/dcfdc042.htm

QUESTION 117The list of available report types displayed in RV2 comes from the fileC:\Datacap\RV2\reports.xml. As a solution designer using a Microsoft SQL Server database, what dbtypeattribute should be set?

A. 0B. 1C. 2

Page 46: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

D. 3

Correct Answer: BSection: Topic 2Explanation

Explanation/Reference:Right AnswerB: dbtype is a flag that tells RV2 how to send TSQL commands to the database. 1 means it's a SQLServer. See below for more information.

http://www-01.ibm.com/support/docview.wss?uid=swg21570601

dbtype 0 is the default.dbtype 1 represents SQL Server. dbtype 2 represents Oracle.

QUESTION 118A medical processing company uses OCR to automatically extract information from medical claim forms.Accurately recognizing this information is critical to ensure customers are billed correctly. To continuallyimprove recognition results the company needs the ability to generate a report of all recognition characterschanged by an index verification operation. Where can the report data be stored and read by the RV2reporting tool?

A. Report data can be stored and read from a XML file.B. Report data can be stored and read from a comma delimited text file.C. Report data can be stored and read from a database located in any accessible location.D. Report data can be stored and read from a database which has to be located in an application directory.

Correct Answer: CSection: Topic 2Explanation

Explanation/Reference:Right AnswerC: The report data can live in an Access database or SQL/Oracle/DB2. (which is generally where it'splaced).

QUESTION 119A solution designer is planning to migrate the databases, along with copying the application, using theDatabase Copy utility to a different station. When using the copy utility, which of the following is NOT acorrect option?

A. Copy All - Copy all of the tables in the Taskmaster application database.

B. Keep Roles - Copy the workflows, jobs, and tasks that are in the application database. Copy the users, groups, stations, shortcuts, or user permissions.

C. Keep Actors and Roles - Copy the workflows, jobs, and tasks that are in the application database. Do not copy the users, groups, stations, shortcuts, or user permissions.

D. Keep Actors - Copy the workflows, jobs, and tasks that are in the application database. Copy the user permissions in the application database if they are compatible on both systems. Do not copy the users, groups, stations, or shortcuts.

Correct Answer: BSection: Topic 2Explanation

Page 47: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

Explanation/Reference:Right AnswerB: You don't want to copy user information to a different station from a design workstation, otherwise yourother user won't be able to do anything, and you may give improper access.

QUESTION 120A customer is using the IBM Datacap Taskmaster Capture Studio Test tab. Which activity will assist inidentifying an action suspected of being misconfigured that is used in multiple functions and returns Truewhen executed?

A. Toggling the A! breakpoint option.B. Toggling the Set Breakpoint option on the suspected action.C. Toggling the Set Full Breakpoint option on the suspected action.D. Toggling the Target Object option on the DCO object the suspected action is executing against.

Correct Answer: BSection: Topic 2Explanation

Explanation/Reference:Right AnswerB: Because it's running under multiple functions you need to step through them one-by-one. If you knowVisual Studio you'll know why this is the right answer.

QUESTION 121An IBM Datacap Taskmaster Capture administrator is troubleshooting an issue with the batch profiler taskwhich runs in the Rulerunner service. After the Rulerunner service processes the task, the batch folderdoes not contain a "batch profiler_rrs.log" file. How can rrs logging be enabled for this task?

A. In tmweb.net's Administrator tab > Workflow > Job > Task (Batch Profiler) > Setup dialog, setRulerunner service log to 3 or higher.

B. In Task Master Server Manager > logging tab > Rulerunner log tab, move the sliders to the right andcheck the Batch log check box.

C. In Rulerunner Manager (connect on login tab) > logging tab > RRS log tab, move the sliders to the rightand check the Batch log check box.

D. In Rulerunner Manager (connect on login tab) > Workflow:Job:Task tab > expand the appropriate threadand select the task; then in the properties grid for the task, set the RRS logging property value to true.

Correct Answer: CSection: Topic 2Explanation

Explanation/Reference:Right AnswerC: You're telling Rulerunner to start logging from whichever source.

Wrong AnswerA and D: These are source log flags. A means you want the Web to log when it runs jobs. D means youwant whatever jobs are going through Workflow to be logged. You still need to tell Rulerunner to actuallycapture the information.

B: This setting only indicates where Rulerunner will put its files. It doesn't have anything to do withinstructing Rulerunner to do the work.

QUESTION 122Which of the following is TRUE when comparing OCR (Optical Character Recognition) and ICR (IntelligentCharacter Recognition) for a typical IBM Datacap Taskmaster Capture application?

A. OCR is more expensive.B. OCR is a lot faster than ICR.C. OCR is generally chosen for handprint recognition.

Page 48: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

D. ICR is typically done at a field level, OCR is at page level.

Correct Answer: DSection: Topic 2Explanation

Explanation/Reference:NOTE: Be careful with this one. While technically B is also true, the "typical IBM Datacap TaskmasterCapture application" part means that the speed difference is marginal. This is due to how Datacap runs thecapture recognition vs. other products - Datacap is one of selective few that handles ICR differently in thismanner.

QUESTION 123A solution designer has moved an application from a development environment into production. In a client /server environment, when the IBM Datacap Taskmaster Capture component is started on a client computerfor the first time, the component cannot communicate with the Taskmaster server and authentication errorsoccur. An "impedes communication" error between the client computer and the Taskmaster Server hasdisplayed. TMA setting is configured correctly. The dc_KTF.xml file has already been created. What else isneeded to ensure credentials can be authenticated?

A. Ensure group and user were added to LDAP security group.B. Ensure group and user were added to LLLDAP security group.C. Copy dc_KTF.xml from IBM Datacap Taskmaster server to the client computer and run "dcskey.exe i"

command.D. Copy dcskey.exe from IBM Datacap Taskmaster server to the client computer and run "dcskey.exe z"

command.

Correct Answer: CSection: Topic 2Explanation

Explanation/Reference:Likely, the encryption key isn't valid for some reason. Running dcskey -i creates a new key.

QUESTION 124A customer is in the process of designing an IBM Datacap Taskmaster Capture application. The customeris trying to determine the best application and method of ingesting paper documents, with information onboth sides, at a scan station in their local network.

What are the two best methods of ingestion for the customer's custom Taskmaster application?

A. Use Taskmaster Web Client, using a ISIS scanner with the duplex option enabled to scan and thenupload the documents.

B. Use Taskmaster DotEdit, using a Kofax scanner driver with the duplex option enabled to scan and thenupload the documents.

C. Use Taskmaster DotScan using ISIS or TWAIN scanner for the scan users to scan in new batches withthe duplex option enabled.

D. Using a third party application with a scanner, the users scan then upload the images to a networkfolder which is ingested by a RuleRunner Server using the Vlmport application.

E. Use FastDoc in Taskmaster mode using ISIS or TWAIN scanner for the scan users to scan in newbatches with the duplex option enabled, then sending the batch to a Taskmaster server for processing.

Correct Answer: CESection: Topic 2Explanation

Explanation/Reference:Right Answers:C: DotScan is locally connected and can scan duplex.E: FastDoc is locally connected and can scan duplex in disconnected mode.

Page 49: IBM Certified Solution Designer - Datacap Taskmaster Capture 8 · 2019-11-09 · In IBM Datacap Taskmaster Capture V8.0.1, the recommended HA configuration for Taskmaster Server is

Wrong AnswersA: Web Client isn't local to the user.B: DotEdit isn't a scan client.D: Images scanned to a network folder aren't duplex.

http://www.gratisexam.com/