CN D&T Group
IAD Configuration (SS)
V1.1
![Page 2: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/2.jpg)
2
Objects
1. Configuration of SPC Property
2. Configuration of SPC Capacity
3. IAD Gateway Cluster Configuration
4. Configuration of Data Area Capacity
5. Zone to Card Configuration
6. Reboot the SPC Card
7. IAD Node Configuration
8. IAD User Configuration
9. TID Default Attribute Configuration
10. Configuration of the TID Name
These slides will show you the details about IAD configuration on SS. Including the following steps:
![Page 3: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/3.jpg)
3
Configuration of SPC Property
We must select Call & H.248 in processing scope to configure IAD on particular SPC Card
Right Click SS Configure Management Globe Configuration SS Data Configuration Shelf Configuration Right Click SPC Card Property Configuration
![Page 4: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/4.jpg)
4
Configuration of SPC Property
Chennai IAD has Configured in 3rd Shelf 14th SPC Card (LSQ=94)
LSQ= [(Shelf No.-1)*40+Slot No.]
![Page 5: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/5.jpg)
5
Configuration of SPC Capacity
Right Click SS Configure Management Globe Configuration SS Data Configuration Shelf Configuration Right Click SPC Card Property Configuration
The Capacity should be filled in according to the actual situation
For IAD, the following should be configured.
Capacity of the TID text
Subscriber Capacity
Maximum Nodes
![Page 6: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/6.jpg)
6
Configuration of SPC Capacity
![Page 7: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/7.jpg)
7
IAD Gateway Cluster Configuration
Gateway Cluster is the set of gateway nodes with the same properties. The nodes with different equipment types cannot exist in the same gateway cluster. In the SS system, SPC data area and hundred groups are allocated in the unit of gateway cluster. Before addition of IAD equipment, the gateway cluster where this IAD equipment resides should be configured.
Right Click SS Configure Management
![Page 8: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/8.jpg)
8
IAD Gateway Cluster Configuration
![Page 9: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/9.jpg)
9
IAD Gateway Cluster Configuration
Chennai IAD Zone=100
Area Code=44
![Page 10: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/10.jpg)
10
Configuration of Data Area Capacity
The SPC of SS control equipment processes calls & protocols based on the gateway cluster. After a gateway cluster is added, we need to allocate an SPC for it.
Right Click SS Configure Management Globe Configuration SS Data Configuration Shelf Configuration Right Click SPC Card Data Area Capacity Configuration Click “Add”
![Page 11: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/11.jpg)
11
Configuration of Data Area Capacity
![Page 12: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/12.jpg)
12
Configuration of Data Area Capacity
![Page 13: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/13.jpg)
13
Configuration of Data Area Capacity
![Page 14: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/14.jpg)
14
Zone to Card Configuration
We must allocate services, protocols and authentication of users in the zone (gateway cluster) to the SPC board for processing.
![Page 15: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/15.jpg)
15
Configuration of Data Area Capacity
Chennai Zone=100
SPC Card=94
![Page 16: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/16.jpg)
16
Reboot the SPC Card
Right Click SS and Select Command Line Terminal
![Page 17: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/17.jpg)
17
Reboot the SPC Card
Command: 1211:3, 14,”YYYYMMDD”
![Page 18: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/18.jpg)
18
IAD Node Configuration
Double Click on the zone to which a node is added to enter the zone
![Page 19: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/19.jpg)
19
IAD Node Configuration
Chennai Node ID=100
Chennai IAD IP=10.64.2.22
![Page 20: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/20.jpg)
20
IAD Node Configuration
Device Property
![Page 21: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/21.jpg)
21
IAD User Configuration
DNHM Configuration
1. Local Office Code
Click Add and Select Add Local Office Code
![Page 22: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/22.jpg)
22
IAD User Configuration
Chennai Area Code=44
Office Code for IAD=8888
User No. Length=3
![Page 23: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/23.jpg)
23
IAD User Configuration
2. Configuration of the Hundred Group
Click Add and Select Add Hundred Set
Click the Hundred groups to be allocated, and press [<], this hundred group will be moved to the list on the left, which means that this hundred group will be allocated to the Zone.
![Page 24: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/24.jpg)
24
IAD User Configuration
Local Office User Configuration
User Configuration Local Office User Configuration Click “Add”
![Page 25: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/25.jpg)
25
TID Default Attribute Configuration
Here we have to specify the default property template and packet template ID for different terminal types.
Enter in to the Zone and Select Default Attribute Configuration
![Page 26: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/26.jpg)
26
TID Default Attribute Configuration
Click “Add” Subscriber
![Page 27: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/27.jpg)
27
TID Default Attribute Configuration
RTP
![Page 28: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/28.jpg)
28
Configuration of the TID Name
TID Name is the terminal ID in the H.248 protocol, used for identifying the physical termination point (user circuit) and the logic termination point (RTP Port).
![Page 29: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/29.jpg)
29
Configuration of the TID Name
Select “Add” then “Add TID Name”
User Circuit
![Page 30: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/30.jpg)
30
Configuration of the TID Name
RTP Port
![Page 31: Iad configuration(ss) 31](https://reader034.fdocuments.in/reader034/viewer/2022052412/55944cb11a28ab396f8b462a/html5/thumbnails/31.jpg)