I9500 to SCR200 OPT Upgrade Manual Version 1.0.1 Date: 09 August 2016
CONDITIONS
Conditions of Use ▪ Read this manual completely before working on,
or making adjustments to, the Compac equipment
▪ Compac Industries Limited accepts no liability for personal injury or property damage resulting from working on or adjusting the equipment incorrectly or without authorization.
▪ Along with any warnings, instructions, and procedures in this manual, you should also observe any other common sense procedures that are generally applicable to equipment of this type.
▪ Failure to comply with any warnings, instructions, procedures, or any other common sense procedures may result in injury, equipment damage, property damage, or poor performance of the Compac equipment
▪ The major hazard involved with operating the Compac C4000 processor is electrical shock. This hazard can be avoided if you adhere to the procedures in this manual and exercise all due care.
▪ Compac Industries Limited accepts no liability for direct, indirect, incidental, special, or consequential damages resulting from failure to follow any warnings, instructions, and procedures in this manual, or any other common sense procedures generally applicable to equipment of this type. The foregoing limitation extends to damages to person or property caused by the Compac C4000 processor, or damages resulting from the inability to use the Compac C4000 processor, including loss of profits, loss of products, loss of power supply, the cost of arranging an alternative power supply, and loss of time, whether incurred by the user or their employees, the installer, the commissioner, a service technician, or any third party.
▪ Compac Industries Limited reserves the right to change the specifications of its products or the information in this manual without necessarily notifying its users.
▪ Variations in installation and operating conditions may affect the Compac C4000 processor's performance. Compac Industries Limited has no control over each installation's unique operating environment. Hence, Compac Industries Limited makes no representations or warranties concerning the performance of the Compac C4000 processor under the actual operating conditions prevailing at the installation. A technical expert of your choosing should validate all operating parameters for each application.
▪ Compac Industries Limited has made every effort to explain all servicing procedures, warnings, and safety precautions as clearly and completely as possible. However, due to the range of operating environments, it is not possible to anticipate every issue that may arise. This manual is intended to provide general guidance. For specific guidance and technical support, contact your authorised Compac supplier, using the contact details in the Product Identification section.
▪ Only parts supplied by or approved by Compac may be used and no unauthorised modifications to the hardware of software may be made. The use of non-approved parts or modifications will void all warranties and approvals. The use of non-approved parts or modifications may also constitute a safety hazard.
▪ Information in this manual shall not be deemed a warranty, representation, or guarantee. For warranty provisions applicable to the Compac C4000 processor, please refer to the warranty provided by the supplier.
▪ Unless otherwise noted, references to brand names, product names, or trademarks constitute the intellectual property of the owner thereof. Subject to your right to use the Compac C4000 processor, Compac does not convey any right, title, or interest in its intellectual property, including and without limitation, its patents, copyrights, and know-how.
▪ Every effort has been made to ensure the accuracy of this document. However, it may contain technical inaccuracies or typographical errors. Compac Industries Limited assumes no responsibility for and disclaims all liability of such inaccuracies, errors, or omissions in this publication.
INFO
RMAT
ION
Document Control Information
Document Information
Document Details I9500 to SCR200 OPT Upgrade Manual
File Name and Location
Current Revision Author(s) H Kleyer
Authorised By T Mayson Release Date: 09/06/2016
Revision History
Version Date Author(s) Revision Notes
1.0.0 09 August 2015 H Kleyer New manual
1.0.1 01 December 2017 H Kleyer Added after photo
3.
CONTENTS
Contents
Conditions of Use ................................................................................................. 1
Document Control Information ............................................................................ 2
Contents ............................................................................................................... 3
Safety ................................................................................................................... 4
Upgrade ................................................................................................................ 5
Tools Required .......................................................................................... 5 Procedure .................................................................................................. 6
4.
SAFE
TY
Safety
PRECAUTIONS: Always follow safe operating procedures, any national or local regulations and site specific instructions.
Electrical Safety DANGER: Always turn off the power to the OPT before removing the high voltage area Perspex guard. Never touch wiring or components inside the high voltage area with the power on. DANGER: If only using the circuit breaker to isolate the OPT, be aware that the wires leading to the circuit breaker may still be live. CAUTION: Always take basic anti-static precautions when working on the electronics, i.e., wearing a wristband with an earth strap.
Site Safety Always make yourself familiar with all site safety precautions including national and local regulations and general precautions for dealing with flammable liquids and vapour. Obey all company regulations and site specific instructions relating to the installation.
5.
UPGRADE
Upgrade
NOTE: Contact the Helpdesk before you head to site and book one of our technicians. We will need time to reconfigure the OPT. Contact the helpdesk once on-site, before disconnecting the unit, to ensure all transactions from the site are uploaded. The OPT has a UPS backup battery, when mains power is lost the OPT will start beeping. In this state, 12 volt power is still available from the backup battery. This must be disconnected before commencing work. To disconnect the backup battery either turn off the rocker switch on the UPS circuit board or unplug CON3 on the UPS board.
Tools Required
▪ Large Flat-Head Screwdriver ▪ Small Flat-Head Screwdriver ▪ Phillips Screwdriver ▪ T10 Torx Screwdriver ▪ 7mm Nut-Driver ▪ 5.5mm Nut-Driver ▪ 10mm Nut-Driver ▪ Side-Cutters ▪ Pliers ▪ Knife
6.
UPGR
ADE
Procedure
▪ Contact the helpdesk. ▪ Turn off the power to the OPT using the circuit breaker, and turn off the
battery power on the UPS board using the switch. ▪ Record the serial numbers of the I9500 PIN pad and card reader, the
Compac helpdesk will ask for these. ▪ Remove the cable connecting the SCR port of the I9500 PIN pad and the
card reader. ▪ Remove the I9500 card reader from the OPT door using a flat-head
screwdriver, keeping the nuts for the new card reader. ▪ Remove the power cable and the communication cable (COM2) from the
back of the I9500 PIN pad.
COM2
7.
UPGRADE
▪ Remove the I9500 PIN pad from the OPT door using the nut-driver. Use the
Torx screwdriver to remove the screw from the anti-tamper switch. ▪ Remove the privacy shield from the front of the OPT door using the Torx
screwdriver. ▪ Securely cable-tie the PIN pad ends of the communication and power
cables out of the way to the white cable sheath winding. ▪ Unplug the communications cable from COM2 on the back of the Compac
Box. ▪ Securely cable-tie the Compac Box end of the communications cable out of
the way. ▪ Remove the power cable from CON8 of the UPS board.
Pull the UPS board end of the power cable back through the gland and insulate it using heatshrink or a connector and tape, and then cable-tie it securely out of the way.
Power off the OPT
8.
UPGR
ADE
▪ Fit the new privacy screen to the outside of the OPT door and fit the adapter
plate over the privacy screen studs on the inside of the OPT door. Secure with M3 washers and Nylok nuts.
▪ Fit the new SCR200 card reader using the nuts form the I9500 card reader, ensuring correct orientation.
9.
UPGRADE
▪ Fit the SCR200 Pin pad to the adapter plate using M4 washers and Nylok
nuts, with the PIN pad’s anti-tamper switch secured to the stud on the top left, and the card reader’s anti tamper switch secured to the stud on the bottom left.
▪ Connect the PIN pad and card reader using the SKP port on the card reader. ▪ Connect the card reader loom to the HOST port on the SCR200 card reader
and COM2 of the Compac Box.
10.
UPGR
ADE
White
Black
▪ Feed the power cable of the card reader loom behind the UPS board, through the gland and connect it to CON8 of the UPS board with the White core going to 12V and the Black to GND.
▪ Securely cable-tie the card reader loom to the outside of the white cable sheath winding.
11.
UPGRADE
Cable-tie card reader loom to white sheath winding
CON8
▪ Stick sponge strips to the back of the drain bracket and the grooves on the top of the SCR200 card reader and fit the drain bracket over the card reader.
▪ Push the drain bracket forward on the card reader until the bottom of the drain bracket is up against the bottom of the OPT door and cable-tie the back of the drain bracket securely to the card reader.
12.
UPGR
ADE