Hyundai

download Hyundai

of 42

Transcript of Hyundai

  • Electro Electric Systems 0

    Electro Electric Systems

    Power Transformers

  • Electro Electric Systems 1

    Contents

    1. Production Capacity & Manpower

    2. Production Range

    3. Production History

    4. Research & Development Framework

    5. Manufacturing Process

    6. Major Manufacturing & Testing Facilities

    7. Performance Record of Power Transformer

    (above 1300kv BIL)

  • Electro Electric Systems 2

    1) Annual Production Capacity : 100,000MVA

    2) Production Voltage : up to 800kv

    3) Production Capacity : up to 1,300MVA (3 phase)

    4) Factory Space : 53,000(570,000ft)

    5) Manpower for Transformer Factory

    78 Design Engineers (and 17 drafters & general affairs) 960 Workers 30 Test Engineers

    15 R & D Engineers

    Production Capacity & Manpower

  • Electro Electric Systems 3

    Production Range

    1) Oil Immersed Power transformer

    2) Distribution transformer (Below 36kV, 30MVA)

    3) Cast resin transformer (Up to 36kV, 10MVA)

    4) Reactor

    5) SF6 Gas Insulated Power Transformer

    6) Special purpose transformer

    Phase shift transformer Furnace transformer Mobile transformer

  • Electro Electric Systems 4

    Distribution TransformerPower Transformer

    Traction TransformerShunt ReactorCast Resin Transformer

  • Electro Electric Systems 5

    SF6 Gas Insulated Power Transformer1PH 60Hz 20MVA154/23kV OLTC

    Mobile Transformer3PH 60Hz 40MVA 154/23kV

  • Electro Electric Systems 6

    Regional Distribution of Annual Production MVA

    ASIA (3.0%)

    Year of 2008

    NORTH AMERICA (46.1%)

    MIDDEL EAST (28.1%)

    KOREA (13.5%)

    EUROPE (3.5%)

    OTHERS (5.1%)

    Year of 2007

    NORTH AMERICA (38.8%)

    MIDDEL EAST (31.6%)

    KOREA (14.3%)

    EUROPE (3.4%)

    OTHERS (5%)

    ASIA (6.9%)

  • Electro Electric Systems 7

    765 kV

    1997

    Annual Produced MVAVoltage class vs. Develop Year

    154kV

    1978

    345kV220kv

    1979

    400kV

    1985

    500kV

    1993

    Production History

    40,200

    61,40067,800

    25,900

    36,900

    2004 2005 2006 2007 2008

  • Electro Electric Systems 8

    Electro Mechanical Research Institute

    -Electro Magnetic Analysis-Thermal & Fluid Analysis

    Industrial Research Institute

    -Material-Mechanical strength

    Maritime Research Institute

    -Vibration & Noise

    Research & Development Framework

    Hyundai Technologies CenterHungary Ltd.

    VIT(Ukraine TransformerResearch Institute)

    Technology Development

    Center

  • Electro Electric Systems 9

    RADIATORTANK / COVERCLAMPCOREINSULATIONCOIL

    CORE/COILASSEMBLY

    MANUFACTURE MANUFACTURE SLITTING/CUTTING PRE-TREATMENT PRE-TREATMENT PRE-TREATMENT

    1 3 4 6 8

    WINDING LAMINATION PAINTING PAINTING

    INSIDE COATING

    SIZING/DRYING 5 7 9

    102

    PAINTING/DRYING

    11

    DRYING

    TANKING

    12

    FINAL ASSEMBLY

    OIL FILLING

    13

    TEST 14FINAL

    PAINTING 15 PACKING DELIVERY

    OLTC, NLTCLEAD CONNECTION

    BUSHING, BCT,ACCESSORIES

    : MANUFACTURING PROCESS

    : HOLD & CHECK POINT

    LEGEND

    Manufacturing Process

  • Electro Electric Systems 10

    1) Lightning Impulse Test System : 4000 kV / 600 kJ

    2) AC Voltage Test System : 1200 kV, 4 A

    3) Partial Discharge Measuring Equipment : PD detector, RIV meter

    4) Condenser Bank : 3158kV, 225 MVAR

    5) M/G Set : 1500kW Motor, 23MVA Generator

    6) Auxiliary Transformer : 3100MVA 6.6/100-250 kV

    7) Sweep Frequency Response Analyzer : Doble M5100

    8) Over-Head Crane (heaviest) : 2 x 300 Ton, 23m(H)

    600 Ton Transporter

    9) Vapor phase Drying Plant (max.) : L 13.8 x W 5.8 x H 7.2

    Major Manufacturing &Testing Facilities

  • Electro Electric Systems 11

    Pictures of Major Testing Equipment

    LightningImpulse Tester

    Condense Bank

    AC VoltageTester

    Frequency Response Analyzer:M5100

  • Electro Electric Systems 12

    Winding Manufacturing Shop

    Temperature Humidity Control Equipment

    Core & Coil Assembly Shop Entrance

    Air Shower

    Air Shower

    Room Temperature : 28Maximum Humidity : 65%Particles : 100,000 EA/ft( 0.5m)

    Clean Room Facilities

  • Electro Electric Systems 13

    Moisture Content 0.5%

    Insulation Material

    Moisture Content 10 ppm

    Insulation Oil

    Vapor Phase Drying Plant Breakdown Voltage 60 kv

    Particle Count Class 4 NAS 1638

  • Electro Electric Systems 14

    400kV New Factory

    Factory Space : W106 x L120 x H36[m] (12,300 )

    Establish Date : Nov. 25. 2008

  • Electro Electric Systems 15

    Facilities of the 400kV New Factory

    Overhead crane: 2 x 250 tonsVapor phase Drying Plant : 4unitsW5.8 x L13.8 x H7.2[m]

    Dustproof SystemAir Transporter : 2 x 300 tons 400kv Test Facilities

  • Electro Electric Systems 16

    1) Middle East & Asia

    Country Customer(Application) Qty Capacity Rated Voltage Delivery

    IragState Organization of Electricity(SOE)(Super Grid 400kv Substation)

    52 1PH 83.3MVA400/138.6/11( 1300 BIL )

    1986,7,8

    UAE

    SIEMENS-KWU/ADWEA(AL-TAWEELAH PROJECT)

    3 3PH 190/280MVA15.75/420(1425 BIL)

    1999

    1 3PH 228/340MVA10.5-10.5/420

    (1425 BIL)1999

    DEWA (JEBEL ALI D POWER)

    3 3PH 137.8/176MVA15/450

    ( 1425 BIL )2001

    KOREA

    Korea Electric Power Corporation(Dang-Jin TPP)

    7 1PH 204MVA 20.9/765( 2050 BIL ) 1999/2000

    4 1PH 370MVA 765/345/23( 2050 BIL )

    1999

    Korea Electric Power Corporation (Shin- Soesan substation)(Shin-Gapheung substation)(Shin-Ansung substation)

    7186

    1PH 667MVA 765/345/23( 2050 BIL )

    200020022004

    Performance Record of Power Transformer (above 1300kv BIL)

  • Electro Electric Systems 17

    2) South & North America(1)

    Country Customer(Application) Qty Capacity Rated Voltage Delivery

    Colombia

    Interconexion Electrica S.A. E.S.P (ISA) (BM75) 3 1PH 90/120/150MVA

    500/230/34.5( 1550 BIL )

    1997

    Interconexion Electrica S.A. E.S.P (ISA) (TPS-202) 3 1PH 90/120/150MVA

    500/230/34.5( 1550 BIL )

    1997

    CanadaBritish Columbia Hydro andPower Authority (BCHP)

    2 3PH 305/400/500MVA 512.5/242/25.2( 1550 BIL ) 1994

    USA

    Zachry Construction Corporation(GEORGIA GENERATING PROJECT)

    2+1 3PH 234/312/390MVA18-18/500

    ( 1425 BIL )2000,1

    SIEMENS-WESTINGHOUSE(BIG SANDY PROJECT)

    2 3PH 126/168/210MVA16/525

    ( 1425 BIL )2001

    1 3PH 156/208/260MVA16/525

    ( 1425 BIL )2001

    OREGON TRANSMISSION LINE(TRACY SUBSTATION)

    3 1PH 170/226/283MVA525/30/34.5KV(1425 KV BIL)

    2001

  • Electro Electric Systems 18

    - Continuance -

    Country Customer(Application) Qty Capacity Rated Voltage Delivery

    USA

    TRAC-10(HOT SPRINGS COUNTY PROJECT)

    2 3PH 169/225/281MVA16/525KV

    (1550KV BIL)2002

    1 3PH 187/249/312MVA16/525KV

    (1550KV BIL)2002

    GILBERT/TENASKA(FLUVANNA GEN. S/S PROJECT)

    33PH 115/153/192MVA=>55(65:215MVA)

    18/525KV(1425KV BIL)

    2003

    13PH 265/353/442MVA=>55(65:495MVA)

    22/525KV(1425KV BIL)

    2003

    TRAC-10(CHOCTOW GAS PROJECT)

    2 3PH 169/225/281MVA16/525KV

    (1550KV BIL)2003

    1 3PH 187/249/312MVA16/525KV

    (1550KV BIL)2003

    Southern California Edison(SCE)(VALLEY S/S)

    1 3PH 336/448/560MVA525/120/13.8KV

    (1550KV BIL)2004

  • Electro Electric Systems 19

    SOE Super Grid / Iraq1PH 400/138.6/11KV 83.3MVA

    Auto-Transformer1986~1988 / 52 units

    400kV Transformer

    Description

    Rated Voltage (kV)

    Rating

    H.V M.V L.V400 138.6 11

    Rated Capacity (MVA)H.V M.V L.V

    50/66.7/83.3 50/66.7/83.3 15/20/25Tap Changer type ON Load Tap ChangerCooling System OA / FA / FOA

    Insulation Level (kV)1,300 550 110 110H.V M.V Neutral L.V

    Winding Connection (YNa0d1)

  • Electro Electric Systems 20

    Description

    Rated Voltage (kV)

    Rating

    H.V M.V L.V512 242 25.2

    Rated Capacity (MVA)H.V M.V L.V

    305/400/500 305/400/500 75/84/123Tap Changer type Off Circuit Tap ChangerCooling System OA / FA / FOA

    Insulation Level (kV)1,550 850 150 150H.V M.V Neutral L.V

    Winding Connection YNa0d1

    BC Hydro / Canada3PH 512/242/25.2KV 500MVAAuto-Transformer1994 / 2 units

    500kV Transformer

  • Electro Electric Systems 21

    Tracy SS / USA1PH 525/230/34.5kV283 MVAAuto-Transformer2001 / 3 units

    Description

    Rated Voltage (kV)

    Rating

    H.V M.V L.V525 230 34.5

    Rated Capacity (MVA)H.V M.V L.V283 283 47

    Tap Changer type Off Circuit Tap ChangerCooling System OA / FA / FOA

    Insulation Level (kV)1,425 750 150 200H.V M.V Neutral L.V

    Winding Connection (YNa0d1)

    500kV Transformer

    PresenterPresentation Notes.

  • Electro Electric Systems 22

    Tenaska Power / USA3PH 18/525kV 215 MVA3PH 22/525kV 495 MVA

    GSU Transformer2003 / 3+1 units

    Description

    Rated Voltage (kV)

    Rating

    H.V L.V525 18

    Rated Capacity (MVA)

    Tap Changer type Off-Circuit Tap ChangerCooling System ONAN/ONAF/ONAF

    Insulation Level (kV)1425 150 150H.V H.V.N L.V

    Winding Connection YNd1

    H.V L.V115/153/192(215) 115/153/192(215)

    500kV Transformer

  • Electro Electric Systems 23

    (1) 1PH 765/20.9kV 204 MVA GSU Transformer (7units/1999-2000)

    765kV Transformer

  • Electro Electric Systems 24

    (2) 1PH 765/345/23KV 370MVA Tie-Transformer (4units / 1999)

    765kV Transformer

  • Electro Electric Systems 25

    (3) 1PH 765/345/23KV 667(2x333.3)MVA Auto-Transformer

    765kV Transformer

  • Electro Electric Systems 26

    765KV 370MVA Transformer under testing

  • Electro Electric Systems 27

    Manufacturing flow chart

  • Electro Electric Systems 28

    Manufacturing flow chart

  • Electro Electric Systems 29

    Manufacturing flow chart

  • Electro Electric Systems 30

    Manufacturing flow chart

  • Electro Electric Systems 31

    Manufacturing flow chart

  • Electro Electric Systems 32

    Manufacturing flow chart

  • Electro Electric Systems 33

    Manufacturing flow chart

  • Electro Electric Systems 34

    Manufacturing flow chart

  • Electro Electric Systems 35

    Manufacturing flow chart

  • Electro Electric Systems 36

    Manufacturing flow chart

  • Electro Electric Systems 37

    Manufacturing flow chart

  • Electro Electric Systems 38

    Manufacturing flow chart

  • Electro Electric Systems 39

    Manufacturing flow chart

  • Electro Electric Systems 40

    Manufacturing flow chart

  • Electro Electric Systems 41

    Thank you very much.

    Slide Number 1Slide Number 2Slide Number 3Slide Number 4Slide Number 5Slide Number 6Slide Number 7Slide Number 8Slide Number 9Slide Number 10Slide Number 11Slide Number 12Slide Number 13Slide Number 14Slide Number 15Slide Number 16Slide Number 17Slide Number 18Slide Number 19Slide Number 20Slide Number 21Slide Number 22Slide Number 23Slide Number 24Slide Number 25Slide Number 26Slide Number 27Slide Number 28Slide Number 29Slide Number 30Slide Number 31Slide Number 32Slide Number 33Slide Number 34Slide Number 35Slide Number 36Slide Number 37Slide Number 38Slide Number 39Slide Number 40Slide Number 41Slide Number 42