HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

52
HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS WELCOME TO THE HYPERLANE! NEXANS DATA CENTER SOLUTIONS

Transcript of HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

Page 1: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

WELCOME TO THE HYPERLANE!

NEXANS DATA CENTER SOLUTIONS

Page 2: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

We help you grow your hyperscale data center

Fix yourproblems

Scale up yourdatacenter

Industrialize yournew concepts

Page 3: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

1

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

We help you grow your hyperscale data center

Fix yourproblems

Scale up yourdatacenter

Industrialize yournew concepts

SOLUTIONS AND SERVICES FOR HYPERSCALE DATA CENTERS

Welcome to the Nexans Data Center Solutions catalog. As a connectivity expert, we’re ready to support innovators like you who are building the framework that’s going to take us into the future. At Nexans Data Center Solutions, we offer hyperlane services for digital innovators – to support you in creating the brains of the hyper-connected world. We can help you to scale up your data center, fi x your problems, and industrialize your new concepts. We understand that you need a trusted, responsive technology partner who can help you grow your hyperscale data center. In this catalog, you’ll fi nd a cross-section of our physical layer infrastructure solutions portfolio, along with detailed information on our services.

Our solutions:We can produce and deliver a complete portfolio of high-end physical layer infrastructure products anywhere in the world: from enclosures, pre-terminated assemblies, and patch cords, to pathways and transceivers. You’ll fi nd details on our products in the following pages. We are not limited to what you see here, but this will give you an idea of the breadth of our offering.

Our services: Our experts, backed by our world-class R&D labs, can support you with any specifi c physical-layer-related network challenges you have. And we have the capability to industrialize those new approaches for you and roll them out worldwide. More information on our services is on page 47 of the catalog. We invite you to consider Nexans Data Center Solutions as your personal service team, available 24/7, supported by Nexans’ global strength and expertise – your very own hyperlane, offering you a premium level of service and support.

Page 4: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

2

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

PRODUCTSENCLOSURES

Easy patching and flexible scalability Patch panelsLC Adaptor ModulesMPO Adaptor ModulesMPO-LC Adaptor ModulesOverhead Patching Frame 4U

PRE-TERMINATED ASSEMBLIESPre-Term CableHigh cable density in traysPre-Term DesignPre-Term Optical performanceLC/LC Fiber AssemblyMPO/MPO Fiber AssemblyLANmark-OF ENSPACE Patching AssembliesPolarity with LC/LC Pre-TermPolarity with MPO-LC modules and MPO-MPO Pre-Term for Duplex TransmissionPolarity with MPO Adaptors and MPO-MPO Pre-Terms for Parallel Transmission

p 04p 05p 06p 07p 08p 09p 10

p 12p 14p 14p 15p 15p 16p 17p 18p 19p 20p 21

TABLE OF CONTENTS

Page 5: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

3

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

p 22p 24p 25p 26

p 28p 29p 30

p 34p 36p 37p 38p 40p 42

p 47

PATCH CORDSLC-LC Patch cordsMPO-MPO Patch cordsLANmark-OF Aggregation Assembly

PATHWAYSFIBREROUTE120/240 Series

TRANSCEIVERS40G QSFP+100G QSFP2840G QSFP+ Active Optical Cable100G QSFP28 Active Optical Cable Passive Direct Attach Cables

SERVICES

Page 6: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

ENCLOSURESNexans enclosures offer ultra-high density and scalability without compromising operation. ENSPACE panels feature three individual sliding trays per ‘U’. This format supports 144 LC connections per rack unit. Each individual tray can be pulled forward to allow access to install or disconnect cords.

Page 7: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

5

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

Easy patching and flexible scalability

• Cables mounted with glands • Cables can be attached left,

middle and right of panel

• Can be installed from front and rear

• 12x LC or 6x MPO

• Fingertip access to patch cords • Individual sliding tray with 4 modules • Locking positions when installed,

for patching and before removal

• Internal auto-shutter

• Integrated patch cord guide • Side grips for easy tray

removal

• Sliding and tilting rear drawer

• Reduced diameter patch cord • Uniboot connector

• Opens 180° even with panels below

Page 8: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

6

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

• Optical patch panel with Ultra High Density: up to 144x LCs or 72x MPO in a rack height unit

• Up to 12x ENSPACE modules in 1U • 3 individually sliding trays per 1U for maximum fl exibility during opera-

tion and installation • 3 different locking positions for trays: operational, patching and installa-

tion position • Patch cord management for each individual tray • Labeling front for port identifi cation • Labeling front opens almost 180°: Port identifi cation visible even when

the panel is high in rack • Sliding and tilting tray at the rear of the panel for better access to cables

during initial installation and additions • Optimized for installation of LANmark-OF ENSPACE Pre-Term with cable

glands

Patch Panels

N NUMBER DESCRIPTION HEIGHT UNIT#

MODULES# DLC ADAPTORS/

10G PORTS# MPO ADAPTORS/40G/

100G PORTS

NSPACE.PP1U LANmark-OF ENSPACE Patch Panel 1U 12x Modules Black 1U 12 72 72

NSPACE.PP2U LANmark-OF ENSPACE Patch Panel 2U 24x Modules Black 2U 24 144 144

NSPACE.PP4U LANmark-OF ENSPACE Patch Panel 4U 48x Modules Black 4U 48 288 288

Page 9: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

7

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

LC Adaptor Modules

• ENSPACE module with 12x LC adaptors in the front • Module can be easily mounted into Nexans’ ENSPACE patch panel • Modules can be installed from front and rear of panel • Innovative handle at rear facilitates removal and installation • Ultra High Density: 12 x modules fit into 1U • 144x LC/72x 10G ports into 1U • Integrated inner metal shutters • Optimized for installation with ENSPACE LC/LC Pre-Term • Integrated strip with color coding for quick fiber identification during

installation • Splice holders with heat shrink or aluminum splice protectors are

included as accessories.

N NUMBER DESCRIPTION ADAPTOR COLOR FIBER CATEGORY

NSPACE.PLC12BS LANmark-OF ENSPACE Adaptor Module 12 LC - Singlemode Blue Shutters Integrated Blue SM OS2

NSPACE.PLC12AS LANmark-OF ENSPACE Adaptor Module 12 LC - Multimode Aqua Shutters Integrated Aqua OM3/OM4/OM5

Page 10: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

8

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

MPO Adaptor Modules

• ENSPACE module with 2x,4x or 6x MPO adaptors in the front • Module can be easily mounted into Nexans’ ENSPACE patch panel • Modules can be installed from front and rear of panel • Innovative handle at rear facilitates removal and installation • Ultra High Density: 12 modules fi t into 1U • 72x MPO adaptors/72x 40-100G ports into 1U • Optimized for installation with ENSPACE MPO/MPO Pre-Term • Key up/key down and key up/key up available • Integrated strip for quick port identifi cation during installation

• Modules can be installed from front and rear of panel• Innovative handle at rear facilitates removal and installation• Ultra High Density: 12 modules fi t into 1U• 72x MPO adaptors/72x 40-100G ports into 1U• Optimized for installation with ENSPACE MPO/MPO Pre-Term• Key up/key down and key up/key up available• Integrated strip for quick port identifi cation during installation

N NUMBER DESCRIPTION FIBER CATEGORY KEY ORIENTATION # MPO ADAPTORS

NSPACE.PMTP2A LANmark-OF ENSPACE Adaptor Module 2x MPO - Multimode Key Up Key Down Aqua OM3/OM4/OM5 Up / Down 2

NSPACE.PMTP4A LANmark-OF ENSPACE Adaptor Module 4x MPO - Multimode Key Up Key Down Aqua OM3/OM4/OM5 Up / Down 4

NSPACE.PMTP6A LANmark-OF ENSPACE Adaptor Module 6x MPO - Multimode Key Up Key Down Aqua OM3/OM4/OM5 Up / Down 6

NSPACE.PMTP2G LANmark-OF ENSPACE Adaptor Module 2x MPO - Singlemode Key Up Key Down Green SM OS2 Up / Down 2

NSPACE.PMTP4G LANmark-OF ENSPACE Adaptor Module 4x MPO - Singlemode Key Up Key Down Green SM OS2 Up / Down 4

NSPACE.PMTP6G LANmark-OF ENSPACE Adaptor Module 6x MPO - Singlemode Key Up Key Down Green SM OS2 Up / Down 6

NSPACE.PMTP2U LANmark-OF ENSPACE Adaptor Module 2x MPO - Multimode Key Up Key Up Grey OM3/OM4/OM5 Up / Up 2

NSPACE.PMTP4U LANmark-OF ENSPACE Adaptor Module 4x MPO - Multimode Key Up Key Up Grey OM3/OM4/OM5 Up / Up 4

NSPACE.PMTP6U LANmark-OF ENSPACE Adaptor Module 6x MPO - Multimode Key Up Key Up Grey OM3/OM4/OM5 Up / Up 6

Page 11: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

9

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

MPO-LC Adaptor Modules

• ENSPACE module with 12x LC adaptors in the front and 1 MPO adap-tor in the rear

• Low loss performance for singlemode and multimode for fi ber assembly inside module: 0.5 dB insertion loss per module

• Ultra High Density: 12x modules fi t into 1U • 144x LC into 1U • Metallic shutters are integrated into the LC adaptors • Modules can be installed from front and rear of panel • Innovative handle at rear facilitates removal and installation • Modules available with straight and crossed wiring to support polarity

method B or C • Unpinned/female MPO connector inside module • ENSPACE modules are pre-installed and 100 % factory tested

N NUMBER DESCRIPTION ADAPTOR COLOR FIBER CATEGORY

NSPACE.MSLC12BS LANmark-OF ENSPACE MPO-Module Straight 12 LC - Singlemode Blue Shutters Integrated Blue SM OS2

NSPACE.MSLC12AS LANmark-OF ENSPACE MPO-Module Straight 12 LC - Multimode Aqua Shutters Integrated Aqua OM3/OM4/OM5

NSPACE.MCLC12BS LANmark-OF ENSPACE MPO-Module Crossed 12 LC - Singlemode Blue Shutters Integrated Blue SM OS2

NSPACE.MCLC12AS LANmark-OF ENSPACE MPO-Module Crossed 12 LC - Multimode Aqua Shutters Integrated Aqua OM3/OM4/OM5

Page 12: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

10

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

Overhead Patching Frame 4U

• 19” 4U overhead frame • Ideal in data centers • Metal construction • Straight or angled position

Patch Cord Management Hooks for Overhead Patching Frame 4U

• Required to guide patch cords on both sides of the frame • Easy to mount with 2 screws and cage nuts • Up to 3 hooks on each side • Black fl exible plastic

N NUMBER DESCRIPTION

N345.400 Overhead Patching Frame 4U

N345.401 Patch Cord Management Hooks for Overhead Patching Frame, pair

Page 13: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

11

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

Notes

Page 14: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

PRE-TERMINATED ASSEMBLIESWe have a full range of superior fiber optic cables and top-of-the-line connectors, built to your exact specifications. Every piece is rigorously tested before it leaves our hands, ready to be shipped direct to the job site for immediate installation. It really is that easy.

Page 15: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

13

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

Page 16: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

14

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

Pre-Term cable High cable density in trays

• Cable Pre-Term based on advanced Micro-Bundle technology • Available in strand counts to 288 • Slim high fi ber count cable to allow a maximum of cables in cable trays • Reduced weight in cable trays • Bend insensitive fi ber inside cables • Short bend radius for ease of installation • LSZH = Flame (IEC 60332-1) and fi re retardant (IEC 60332-3),

LSZH jacket • PLENUM = OFNP rating • Armor options available

• Small diameter allows high number of cables • Double or triple amount of cables compared to traditional solutions • Space limitations in central patching zones reduced

4” x 12 “ tray can hold 572 cables of 48-strand (26,456 total strands). 2.5x more than a typical cable.

LSZH PLENUM

Dimension Weight Bend radius operation

Crush resistance Dimension Weight Bend radius

operationCrush

resistance

12 3.6 mm 13.2 40 500 4.1 mm 15 41 500

24 5.4 mm 37 80 1000 4.6 mm 21 46 500

48 5.4 mm 37 80 1000 5.9 mm 33 59 500

72 5.4 mm 37 80 1000 7.0 mm 48 70 500

96 6.4 mm 50 80 1000 8.0 mm 66 80 500

144 8.4 mm 87 1100 1000 9.1 mm 83 91 500

Page 17: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

15

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

Pre-Term Design Pre-Term Optical performance

• All connection types have low loss performance for both singlemode and multimode

• Allows for more connections and longer length

• Protective black net with bubble wrap on one side • Pulling eye one side, other options available • Maximum pulling force on pulling eye: 100 pounds • Protective bubble wrap on second side • Cable gland with rubber boot for strain relief • Small transition fan-out • Made to order with 1m increments to reduce excess lengths

CONNECTION TYPE INSERTION LOSS*

LC Multimode 0.3 dB

LC Singlemode 0.3 dB

LC Singlemode APC 0.3 dB

MPO Multimode 0.3 dB low loss

MPO Singlemode, APC 0.3 dB low loss

*Other loss options available

Page 18: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

16

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

LC/LC Fiber Assembly

• Dual stage fan-out for installation inside the ENSPACE panel and inside the ENSPACE module

• Pre-Term based on Micro-Bundle technology • Cable optimized for installation in data centers: small diameter, small

bend radius and reduced weight • Fibers identifi ed with colored boots • Fiber pair fl ip to maintain transmit-receive polarity implemented in

manufacturing

PLENUM N13y.nnnnaabbEEdeMDPhjxxxxk

N13y.nnnnaabbEEdeMDPhjxxxxk y: fi ber category 7: multimode OM4

9: multimode OM5

4: singlemode OS2

N13y.nnnnaabbEEdeMDPhjxxxxk nnnn: fi ber count

N13y.nnnnaabbEEdeMDPhjxxxxk aa: connector type L: LC

P: LC/APC

N13y.nnnnaabbEEdeMDPhjxxxxk EE: fan-out optimized for ENSPAC E panel

N13y.nnnnaabbEEdeMDPhjxxxxk xxxx: length in m

N13y.nnnnaabbEEdeMDPhjxxxxk k: color cable jacket A: OM4

L: OM5

Y: singlemode

LSZH N15a.DnnbccExxxa

N15a.DnnbccExxxa a: fi ber category 7: multimode OM4

9: multimode OM5

4: singlemode OS2

N15a.DnnbccExxxa nn: fi ber count

N15a.DnnbccExxxa c: connector type L: LC

P: LC/APC

N15a.DnnbccExxxa E: fan-out optimized for ENSPAC E panel

N15a.DnnbccExxxa xxx: length in m

N15a.DnnbccExxxa e: color cable jacket A: OM4

L: OM5

Y: singlemode

Page 19: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

17

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

MPO/MPO Fiber Assembly

• Fiber assembly for installation inside the ENSPACE panel • Cable optimized for installation in data centers: small diameter, small

bend radius and reduced weight • Method B and Method C polarity options available • Pre-Term can be used together with MPO-LC modules for LC connectivity

or with MPO-adaptor modules for parallel optics • Male-male/pinned-pinned Pre-Terms

PLENUM N13y.nnnnMMbbEEdeMDPhjxxxxk

N13y.nnnnMMbbEEdeMDPhjxxxxk y: fiber category 7: multimode OM4

9: multimode OM5

4: singlemode OS2

N13y.nnnnMMbbEEdeMDPhjxxxxk d: polarity for MPO-MPO B: type B polarity

Pre-Term C: type C polarity

N13y.nnnnMMbbEEdeMDPhjxxxxk nnnn: fiber count

N13y.nnnnMMbbEEdeMDPhjxxxxk MM: male MPO-male MPO

N13y.nnnnMMbbEEdeMDPhjxxxxk EE: fan-out optimized for ENSPAC E panel

N13y.nnnnMMbbEEdeMDPhjxxxxk xxxx: length in m

N13y.nnnnMMbbEEdeMDPhjxxxxk k: color cable jacket A: OM4

L: OM5

Y: singlemode

LSZH N15a.PnnMMExxxe

N15a.PnnMMExxxe a: fiber category 7: multimode OM4

9: multimode OM5

4: singlemode OS2

N15a.PnnMMExxxe P: polarity for MPO-MPO B: type B polarity

Pre-Term C: type C polarity

N15a.PnnMMExxxe nn: fiber count

N15a.PnnMMExxxe MM: male MPO-male MPO

N15a.PnnMMExxxe E: fan-out optimized for ENSPAC E panel

N15a.PnnMMExxxe xxx: length in m

N15a.PnnMMExxxe e: color cable jacket A: OM4

L: OM5

Y: singlemode

Page 20: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

18

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

LC SFP+

LANmark-OF ENSPACE Patching Assemblies

• High fiber count fibre assembly for connecting transceivers on switch and ENSPACE modules

• Switch side has a 2mm fan-out with uniboot LC duplex connector for connecting to SFP+ transceivers- customized staggers available

• Panel side:- dual stage 900 μm LC fan-out for installation inside the ENSPACE

panel with the LC ENSPACE adaptor modules- or male MPO-fan out for installation inside the ENSPACE panel with

ENSPACE MPO-LC modules

LSZH N15a.SnnL2L9dxxxe

N15a.SnnL2L9dxxxe a: fiber category 7: multimode OM4

9: multimode OM5

4: singlemode OS2

N15a.SnnL2L9dxxxe nn: fiber count

N15a.SnnL2L9dxxxe L2: uniboot LC connector on switch side

N15a.SnnL2L9dxxxe L9: LC connector inside panel

N15a.SnnL2L9dxxxe d: fan-out length switch side A: equal length 1 meter

B: equal length 1.5 m

C: equal length 2 m

N15a.SnnL2L9dxxxe xxx: length in m

N15a.SnnL2L9dxxxe e: color cable jacket A: OM4

L: OM5

Y: singlemode

PLENUM N13y.nnnnULbbccdeMDPhjxxxxk

N13y.nnnnULbbccdeMDPhjxxxxk y: fiber category 7: multimode OM4

9: multimode OM5

4: singlemode OS2

N13y.nnnnULbbccdeMDPhjxxxxk nnnn: fiber count

N13y.nnnnULbbccdeMDPhjxxxxk U: uniboot LC connector on switch side

N13y.nnnnULbbccdeMDPhjxxxxk L: LC connector inside panel

N13y.nnnnULbbccdeMDPhjxxxxk c: fan-out length switch side K: equal length 1 meter

C: custom length

N13y.nnnnULbbccdeMDPhjxxxxk xxxx: length in m

N13y.nnnnULbbccdeMDPhjxxxxk k: color cable jacket A: OM4

L: OM5

Y: singlemode

Page 21: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

19

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

Polarity with LC/LC Pre-Term

• Colored boots for 900 μm fi bers • Integrated color strip inside ENSPACE LC module • Matching colored boots with colors on strip simplify error free installation

for duplex transmission • Required fi ber pair fl ip in Pre-Term to maintain transmit-receive polarity

introduced during manufacturing

LSZH N15a.SnnL2M3dxxxe

N15a.SnnL2M3dxxxe a: fi ber category 7: multimode OM4

9: multimode OM5

4: singlemode OS2

N15a.SnnL2M3dxxxe nn: fi ber count

N15a.SnnL2M3dxxxe L2: uniboot LC connector on switch side L: LC

N15a.SnnL2M3dxxxe M3: male MPO connector inside panel

N15a.SnnL2M3dxxxe d: fan-out length switch side A: equal length 1 meter

B: equal length 1.5 meter

C: equal length 2 meter

N15a.SnnL2M3dxxxe xxx: length in m

N15a.SnnL2M3dxxxe e: color cable jacket A: OM4

L: OM5

Y: singlemode

PLENUM N13y.nnnnUMbbccdeMDPhjxxxxk

N13y.nnnnUMbbccdeMDPhjxxxxk y: fi ber category 7: multimode OM4

9: multimode OM5

4: singlemode OS2

N13y.nnnnUMbbccdeMDPhjxxxxk nnnn: fi ber count

N13y.nnnnUMbbccdeMDPhjxxxxk U: uniboot LC connector on switch side

N13y.nnnnUMbbccdeMDPhjxxxxk M: male MPO connector inside panel

N13y.nnnnUMbbccdeMDPhjxxxxk c: fan-out length switch side K: equal length 1 meter

C: custom length

N13y.nnnnUMbbccdeMDPhjxxxxk xxxx: length in m

N13y.nnnnUMbbccdeMDPhjxxxxk k: color cable jacket A: OM4

L: OM5

Y: singlemode

Page 22: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

20

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

Polarity with MPO-LC modules and MPO-MPO Pre-Terms for Duplex Transmission

TR

RT

Type BPre-Term

Straight Crossed

TR

RT

Type CPre-Term

Straight Straight

Straight Straight

Straight Crossed

Page 23: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

21

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

Polarity with MPO adaptors and MPO-MPO Pre-Terms for Parallel Transmission

KEYUp /Down

KEYUp /Down

Type BMPO Pre-Term

TR

RT

KEYUp /Up

KEYUp /Down

Type CMPO Pre-Term

TR

RT

Page 24: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

PATCH CORDSPatch cords are made from highly-flexible, bend-insensitive fiber to accommodate high-density patching. A bend radius of 10 mm and round design of the ENSPACE patch cord results in a small bend radius in any direction. With the round design and the small diameter of the patch cable, the area required for the patch cord is reduced by 50%, resulting in space savings, reduced disturbance of the airflow for cooling and easier patch cords management in high density racks.

Page 25: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

23

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

Page 26: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

24

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

LC-LC Patch cords

• Uniboot style duplex LC connectors • Slim round patch cord cable to reduce required space in dense

patching zones • Improved handling in high-density applications • Low-loss connectivity enables system design flexibility • Bend radius reduced with GIGAliteFlex bend insensitive fiber • Designed to withstand tight bends and challenging cable routes • Low-smoke and zero-halogen (LSZH) or Plenum (OFNP) • Flame retardant • Reverse polarity uniboot connector

PLENUM

N NUMBER DESCRIPTION

N137.J002UU33NNBSD2PMxxx.xA LANmark-OF ENSPACE Patch Cord DLC-DLC OM4 xxx.xm Aqua

N139.J002UU33NNBSD2PMxxx.xL LANmark-OF ENSPACE Patch Cord DLC-DLC OM5 xxx.xm Lime Green

N134.J002UU33NNBSD2PMxxx.xY LANmark-OF ENSPACE Patch Cord DLC-DLC OS2 xxx.xm Yellow

LSZH

N NUMBER DESCRIPTION

N122.7UUAx LANmark-OF ENSPACE Patch Cord DLC-DLC OM4 xm Aqua

N122.9UULx LANmark-OF ENSPACE Patch Cord DLC-DLC OM5 xm Lime Green

N122.4UUYx LANmark-OF ENSPACE Patch Cord DLC-DLC OS2 xm Yellow

Page 27: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

25

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

MPO-MPO Patch cords

• MPO-MPO patch cords • Slim round patch cable • Small bend radius • Female-Female patch cord to fi t with male MPO connector of MPO Pre-

Term or male QSFP+ connector • Available in OM4, OM5 and singlemode • Straight wiring with key up/key up (Type A) design • Parallel Optics: 40GBASE-SR4, 100GBASE-SR10 and 100G PSM4 • Low-smoke and zero-halogen (LSZH) and Plenum (OFNP) • Flame and fi re retardant

PLENUM

N NUMBER DESCRIPTION

N137.J012FF33NNASACPMxxx.xA LANmark-OF Patch Cord Female MPO-Female MPO OM4 xxx.xm Aqua

N139.J012FF33NNASACPMxxx.xL LANmark-OF Patch Cord Female MPO-Female MPO OM5 xxx.xm Lime Green

N134.J012FF33NNASACPMxxx.xY LANmark-OF Patch Cord Female MPO-Female MPO OS2 xxx.xm Yellow

LSZH

N NUMBER DESCRIPTION

N125.7FFAx LANmark-OF Patch Cord Female MPO-Female MPO OM4 xm Aqua

N125.9FFLx LANmark-OF Patch Cord Female MPO-Female MPO OM5 xm Lime Green

N125.4FFYx LANmark-OF Patch Cord Female MPO-Female MPO OS2 xm Yellow

Page 28: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

26

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

LANmark-OF Aggregation Assembly

• Female MPO connector for connecting to QSFP+ transceiver on switch • Uniboot DLC connectors for patching on front of patch panel • 4 channels / 8 fi bers • Aggregation of 4 channels into 1 port on switch • Custom lengths and staggers available • Fiber type: OM4, OM5 and singlemode

Page 29: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

27

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

LC MPO QSFP+

LSZH N127.aFbdex

N127.aFbdex a: fiber category 7: multimode OM4

9: multimode OM5

4: singlemode OS2

N127.aFbdex F: female MPO connector for insertion in QSFP+ transceiver

N127.aFbdex b: duplex connector type on front of patch panel L: DLC connector

P: DLC/APC connector

N127.aFbdex d: fan-out length patch panel A: equal length 1 meter

B: equal length 1.5 meters

C: equal length 2 meters

N127.aFbdex e: color cable jacket A: OM4

L: OM5

Y: singlemode

N127.aFbdex x: length in m

PLENUM N13y.H008FabbNcdeACPMxxx.xj

N13y.H008FabbNcdeACPMxxx.xj y: fiber category 7: multimode OM4

9: multimode OM5

4: singlemode OS2

N13y.H008FabbNcdeACPMxxx.xj F: female MPO connector for insertion in QSFP+ transceiver

N13y.H008FabbNcdeACPMxxx.xj a: duplex connector type

on front of patch panel J: DLC connector

P: LC/APC connector

N13y.H008FabbNcdeACPMxxx.xj c: fan-out length patch panel G: equal length 1 meter

C: custom length

N13y.H008FabbNcdeACPMxxx.xj j: color cable jacket A: OM4

L: OM5

Y: singlemode

N13y.H008FabbNcdeACPMxxx.xj xxx.x: length in m

Page 30: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

PATHWAYSFIBREROUTE is intended to be implemented as a dedicated fiber optic pathway to protect fiber cable from damage and maintain high speed transmission.

Page 31: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

29

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

Comprehensive Protection • EASY ACCESS : Enables moves, adds & changes • END-TO-END PROTECTION : Cables protected from damage

throughout • ROBUST : Manufactured from tough plastic • EASY TO HANDLE : Lightweight for easy transport and installation • NO SHARP EDGES : No danger of damaging cables on cut metal

edges • MANAGED BEND RADII : Cable bend radius maintained throughout • COVERS : Keep out dirt and dust • ADAPTORS : Compatible with other fiber trunking systems

Fast installationInstallation is flexible using different channels connected by fittings and adaptors. No plastic welding is needed with all parts joined together using tool-less fasteners.Attachment and supporting devices are available for wall mounting, ceiling hanging, under floor and rack mounting within data centers.

FIBREROUTE Branch FIBREROUTE Main channel

Applied environment EDA/ZDA ZDA/IDA/MDA

Channel size 120 mm 240 mm

Channel capacity

> 900 LC Patch cords* > 1800 LC Patch cords

> 350 40G MPO Patch cords* > 800 40G MPO Patch cords*

> 58 Conventional 96 core MPO trunk cables

> 140 Conventional 96 core MPO trunk cables

> 115 LANmark-OF 96 core MPO trunk cables*

> 290 LANmark-OF 96 core MPO trunk cables*

* The capacity of LC Patch cords is based on ENSPACE LC 2.0 mm Patch cords.

Easy AccessMoves/adds/changes of fiber optic patching are made easy when separated from bunches of copper horizontal cables. Future expansion and interconnection with channels of different sizes is easily accomplished using fittings and tees available in various sizes.Various channel sizes are available to meet different capacity demands in MDA, IDA, ZDA or EDA cabling sub-systems.The Nexans Installation toolkit makes it easy to calculate cable tray fill rates, check the Nexans Data Center Solutions website at www.nexans.com/datacenters for the latest version.

Page 32: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

30

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

120/240 Series

N NUMBER DESCRIPTION

N350.120FC00P FIBREROUTE 120mm Channel – 2m

N350.120FC10P FIBREROUTE 120mm Channel Cover – 2m

N350.240FC00P FIBREROUTE 240mm Channel – 2m

N350.240FC10P FIBREROUTE 240mm Channel Cover – 2m

N NUMBER DESCRIPTION

N350.120FA02A FIBREROUTE 120mm Equal Tee

N350.120FA12A FIBREROUTE 120mm Equal Tee Cover

N350.240FA02A FIBREROUTE 240mm Equal Tee

N350.240FA12A FIBREROUTE 240mm Equal Tee Cover

N NUMBER DESCRIPTION

N350.120FA03A FIBREROUTE 120mm Equal Cross

N350.240FA03A FIBREROUTE 240mm Equal Cross

N350.240FA13A FIBREROUTE 240mm Equal Cross Cover

N NUMBER DESCRIPTION

N350.120FA01A FIBREROUTE 120mm Elbow

N350.120FA11A FIBREROUTE 120mm Elbow Cover

N350.240FA01A FIBREROUTE 240mm Elbow

N350.240FA11A FIBREROUTE 240mm Elbow Cover

Page 33: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

31

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

N NUMBER DESCRIPTION

N350.120FA22A FIBREROUTE 120mm 45° Vertical External Bend

N350.120FA32A FIBREROUTE 120mm 45° Vertical External Bend Cover

N350.240FA22A FIBREROUTE 240mm 45° Vertical External Bend

N350.240FA32A FIBREROUTE 240mm 45° Vertical External Bend Cover

N NUMBER DESCRIPTION

N350.120FC03A FIBREROUTE 120mm End-cap

N350.240FC03A FIBREROUTE 240mm End-cap

N NUMBER DESCRIPTION

N350.120FA21A FIBREROUTE 120mm 45° Vertical Internal Bend

N350.120FA31A FIBREROUTE 120mm 45° Vertical Internal Bend Cover

N350.240FA21A FIBREROUTE 240mm 45° Vertical Internal Bend

N350.240FA31A FIBREROUTE 240mm 45° Vertical Internal Bend Cover

N NUMBER DESCRIPTION

N350.120FC01A FIBREROUTE 120mm In-line Connector

N350.240FC01A FIBREROUTE 240mm In-line Connector

Page 34: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

32

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

N NUMBER DESCRIPTION

N350.120FC02A FIBREROUTE 120mm Trumpet

N NUMBER DESCRIPTION

N350.240FT01A FIBREROUTE 240mm-120mm Reducer

N350.240FT11A FIBREROUTE 240mm-120mm Reducer Cover

N NUMBER DESCRIPTION

N350.120FA04A FIBREROUTE 120mm Universal Transition

N350.240FA04A FIBREROUTE 240mm Universal Transition

N NUMBER DESCRIPTION

N350.240FT21A FIBREROUTE 240mm–120mm Vertical Unequal Tee

N350.240FT31A FIBREROUTE 240mm–120mm Vertical Unequal Tee Cover

Page 35: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

33

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

N NUMBER DESCRIPTION

N350.240FT41A FIBREROUTE 240mm-120mm Tee Reducer

N350.240FT51A FIBREROUTE 240mm-120mm Tee Reducer Cover

N NUMBER DESCRIPTION

N350.003SD01A FIBREROUTE Waterfall Assembly 90mm

N350.003SD02A FIBREROUTE Waterfall Assembly 130mm

N350.003SD10A FibreRoute Waterfall Flexible tube, 50mm, 0.8M

Accessories

N NUMBER DESCRIPTION

N350.003SD01A FIBREROUTE Waterfall Assembly 90mm

N350.003SD02A FIBREROUTE Waterfall Assembly 130mm

N350.003SD10A FIBREROUTE Waterfall Flexible tube, 50mm, 0.8M

N350.003SS00S FIBREROUTE Screw Kit Tube Type x100

N350.003SS01S FIBREROUTE Screw Kit Round Type x100

N350.003SMT2 FIBREROUTE 240mm Trapeze Mounting Kit

N350.003SMT1 FIBREROUTE 120mm Trapeze Mounting Kit

N350.003SMC2 FIBREROUTE 240mm Cable Tray Mounting Kit

N350.003SMC1 FIBREROUTE 120mm Cable Tray Mounting Kit

N350.003SMR2 FIBREROUTE 240mm Cabinet/Rack Mounting Kit

N350.003SMR1 FIBREROUTE 120mm Cabinet/Rack Mounting Kit

N NUMBER DESCRIPTION

N350.240FT61A FIBREROUTE 240mm-120mm Unequal Cross

N350.240FT71A FIBREROUTE 240mm-120mm Unequal Cross Cover

Page 36: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

TRANSCEIVERS

Page 37: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

35

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

Introduction

Maximize performance. In recent years, the number of transceiver options has dramatically increased. Since the transceiver decision has a direct impact on the cabling infrastructure (and vice versa), transceiver and cabling decisions should be considered together. In addition, ever-increasing bandwidth demand continues to drive changes to your network and data center. In fact, in the coming years, you will sure-ly need more servers, more switches and more storage capacity connected at higher data rates. That’s why it’s so important to “own the link.”

What does that mean? In the past, transceivers have been pur-chased from equipment manufacturers, but since a transceiver’s perfor-mance has more to do with the cabling than the equipment, it makes more sense to specify the cable and transceivers together. That way, you own the entire link.Longer reach + more connections. Using Nexans’ 40Gbps transceivers paired with our GIGAlite-10XB glass, we guarantee enough power budget to support a link distance of up to 500 meters over multimode fiber. Standard compliant solutions offer only 150 meters at 40Gbps. Of course, you can trade off distance for more connections, but with Nexans’ solutions, you have the flexibility to scale your network and data center to meet your current and future needs.

Page 38: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

36

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

40G QSFP+

• 4 channel 10.3125 GBd bi-directional transceiver • module • Compliant with IEEE 802.3ba 40GBASE XLPPI Electrical Interface and

SFF8436 • Hot-pluggable QSFP footprint • Built-in real-time digital diagnostics monitoring • Class 1 laser product complies with EN 60825-1 • Enhanced performance when used in conjunction with Nexans GIGAlite

glass • Operating temperature range: 0°C to 70°C

QSFP-40GBE-SR4 • Compliant with IEEE 802.3ba 40GBASE-SR4 • Uncooled 850 nm VCSEL laser transmitter • 12-fiber MPO connector • Power consumption < 1.5 Watts

QSFP-40GBE-SR4+ • Compliant with IEEE 802.3ba 40GBASE-SR4 • Uncooled 850 nm VCSEL laser transmitter, 500 m with GIGAlite10-XB • 12-fiber MPO connector • Power consumption < 1.5 Watts

QSFP-40GBE-LR4 • Compliant with IEEE 802.3ba 40GBASE-LR4 • 1310 nm DFB laser transmitter, 10 km • 2-fiber Duplex-LC • Power consumption < 3.5 Watts

QSFP-40GBE-LR4L • Compliant with IEEE 802.3ba 40GBASE-LR4 • 1310 nm DFB laser transmitter, 2km • 2-fiber Duplex LC connector • Power consumption < 3.5 Watts

QSFP-40GBE-PSM4 • Compliant with IEEE 802.3ba 40GBASE-LR4 • 1310 nm DFB laser transmitter, PSM4, 2km • 12-fiber MPO connector • Power consumption < 3.5 Watts

40 Gb Ethernet QSFP + Transceiver

Page 39: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

37

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

100G QSFP28

• 4 channel 26.5 GBd bi-directional transceiver • module • Compliant with IEEE 802.3bm 100GBASE XLPPI Electrical Interface and

SFF8655 • Hot-pluggable QSFP28 footprint • Built-in real-time digital diagnostics monitoring • Class 1 laser product complies with EN 60825-1 • Enhanced performance when used in conjunction with Nexans GIGAlite

glass • Operating temperature range: 0°C to 70°C

QSFP-100GBE-SR4 • Compliant with IEEE 802.3bm 100GBASE-SR4 • Uncooled 850 nm VCSEL laser transmitter • 12-fi ber MPO connector • Power consumption < 2.5 Watts

QSFP-100GBE-SR4+ • Compliant with IEEE 802.3bm 100GBASE-SR4 • Uncooled 850 nm VCSEL laser transmitter, enhanced reach with

GIGAlite10-XB • 12-fi ber MPO connector • Power consumption < 2.5 Watts

QSFP-100GBE-LR4 • Compliant with IEEE 802.3bm 100GBASE-LR4 • 1310 nm DFB laser transmitter, 10 km • 2-fi ber Duplex-LC • Power consumption < 4.5 Watts

QSFP-100GBE-CW4 • Compliant with 100G-CWDM4 MSA and IEEE Electrical Interface • RS FEC • 1310 nm DFB laser transmitter, 2km • 2-fi ber Duplex LC connector • Power consumption < 3.5 Watts

QSFP-100GBE-PSM4 • Compliant with 100G PSM4 MSA and IEEE 802.3bm Electrical

Interface • 1310 nm DFB laser transmitter, PSM4, 500 m • 12-fi ber MPO connector • Power consumption < 3.5 Watts

100 Gb Ethernet QSFP28 Transceiver

Page 40: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

38

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

40G QSFP+ Active Optical Cable

Active Optical Cable (AOC)

• 4 channel up to 11.2 GBd parallel Multimode Active Optical Cable • 40GBASE Ethernet, SDR, QDR Infi niband • Compliant with IEEE 802.3ba 40GBASE XLPPI Electrical Interface and

SFF8436 • Hot-pluggable QSFP footprint • Built-in real-time digital diagnostics monitoring • Class 1 laser product complies with EN 60825-1 • Operating temperature range: 0°C to 70°C

AQPM40GXXX (XXX is length in meters) • 1 – 100 m QSFP+ to QSFP+ 4x10G Parallel Multimode Active Optical

Cable • Compliant with IEEE 802.3ba 40GBASE-SR4 • Uncooled 850 nm VCSEL laser transmitter • Power consumption < 1.5 Watts per module

IMAGE

IMAGE

Page 41: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

39

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

AOC Breakout Cable

• 4 channel up to 11.2 GBd parallel Multimode, Breakout Active Optical Cable

• 40GBASE Ethernet, SDR, QDR Infiniband • Compliant with IEEE 802.3ba 40GBASE XLPPI Electrical Interface and

SFF8436 • Hot-pluggable QSFP footprint • Built-in real-time digital diagnostics monitoring • Class 1 laser product complies with EN 60825-1 • Operating temperature range: 0°C to 70°C

AQPM4x10GXXX (XXX is length in meters) • 1 – 100 m QSFP+ to 4x 10G SFP+ Parallel Multimode Breakout Active

Optical Cable • Compliant with IEEE 802.3ba 40GBASE-SR4 • Uncooled 850 nm VCSEL laser transmitter • Power consumption < 1.5 Watts for QSFP+ module, <1W for SFP+

module

Page 42: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

40

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

Active Optical Cable

100G QSFP28 Active Optical Cable (continued)

• 4 channel up to 28 GBd parallel Multimode Active Optical Cable • 100GBASE Ethernet, SDR, QDR Infi niband • Compliant with IEEE 802.3bm 100GBASE XLPPI Electrical Interface and

SFF8655 • Hot-pluggable QSFP28 footprint • Built-in real-time digital diagnostics monitoring • Class 1 laser product complies with EN 60825-1 • Operating temperature range: 0°C to 70°C

AQPM100GXXX (XXX is length in meters) • 1 – 100 m QSFP28 to QSFP28 4x10G Parallel Multimode Active

Optical Cable • Compliant with IEEE 802.3ba 40GBASE-SR4 • Uncooled 850 nm VCSEL laser transmitter • Power consumption < 2.5 Watts per module

IMAGE

IMAGE

Page 43: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

41

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

AOC Breakout Cable

• 4 channel up to 28 GBd parallel Multimode, Breakout Active Optical Cable

• 100GBase Ethernet, SDR, QDR Infiniband • Compliant with IEEE 802.3bm 100GBASE XLPPI Electrical Interface and

SFF8655 • Hot-pluggable QSFP28 footprint • Built-in real-time digital diagnostics monitoring • Class 1 laser product complies with EN 60825-1 • Operating temperature range: 0°C to 70°C

AQPM4x25GXXX (XXX is length in meters) • 1 – 100 m QSFP28 to 4xSFP28 4x25G Parallel Multimode Active

Optical Cable • Compliant with IEEE 802.3bM 100GBASE-SR4 • Uncooled 850 nm VCSEL laser transmitter • Power consumption < 2.5 Watts for QSFP28, <1W per SFP28 module

Page 44: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

42

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

Passive Direct Attach Cables

Direct Attach Cable (DAC)

• Up to 10 Gb/s passive direct attach connection • Compatible to SFP+ MSA, SFF-8431 and SFF-8432 • 10GBASE Ethernet Application • Operating temperature range: 0°C to 70°C • RoHS Compatible

DAxxPS10Gyyy (yyy is length in meters) • 0.5 – 5 m (yyy) SFP+ to SFP+ 10G Passive Direct Attach Cable, xx

AWG • Backwards compatible to 1Gb/s • 30AWG up to 3 m • 26 AWG 3m – 5m

IMAGE

IMAGE

Page 45: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

43

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

Direct Attach Cable (DAC)

• Up to 25.8 Gb/s passive direct attach connection • Compatible to SFP28 MSA, SFF-8402 and SFF-8432 • Operating temperature range: 0°C to 70°C • RoHS Compatible • 4-Channel, 11.2 Gb/s Passive Direct Attach Cable • Compatible to QSFP+ MSA, SFF-8436 • 40GBASE Ethernet, Infi niband QSD, DDR • Operating temperature range: 0°C to 70°C • RoHS Compatible

DAxxPS25Gyyy (yyy is length in meters) • 0.5 – 5 m (yyy) SFP+ to SFP+ 25G Passive Direct Attach Cable, xx

AWG • 30AWG up to 2 m • 26 AWG 2m – 5m

DAxxPQ40Gyyy (yyy is length in meters) • 0.5 – 5 m (yyy) QSFP+ to QSFP+ 40G Passive Direct Attach Cable, xx

AWG • Backwards compatible to 1Gb/s • 30AWG up to 3 m • 26 AWG 3m – 5m

IMAGE

IMAGE

Page 46: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

44

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

Passive Direct Attach Cables (continued)

DAC Breakout Assembly

• 4-Channel, 11.2 Gb/s Passive Direct Attach Breakout Cable • Compatible to QSFP+ MSA, SFF-8436 • Compatible to SFP+ MSA, SFF-8431 and SFF-8432 • 40GBASE to 4x 10GBASE Ethernet Breakout • Operating temperature range: 0°C to 70°C • RoHS Compatible

DAxxPQ4X10Gyyy (yyy is length in meters) • 0.5 – 5 m (yyy) QSFP+ to 4x SFP+ Passive Direct Attach Breakout

cable, xx AWG • Backwards compatible to 1Gb/s • 30AWG up to 3 m • 26 AWG 3m – 5m

Page 47: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

45

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

Notes

Page 48: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS
Page 49: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

47

Enclosures Pre-terminated assemblies Patch cords Pathways Transceivers Services

We can support you in scaling up your hyperscale data center, fixing your problems and industrializing your new concepts.

Scale up your capacity when and where you needWe understand that you’re not just adding nodes to corporate infrastruc-ture. You’re developing an innovation platform that’s expanding rapidly. Refresh cycles happen in weeks, and scalability and resilience are key to support current solutions and enable fast-paced innovations on a global scale.

Fix your problems as soon as they occur We know that you’re a pioneer in what you’re doing, and you’re piloting new approaches. We can support you in fixing any of your physical-lay-er-related network problems that crop up, as quickly as possible.

Industrialize your new conceptsWe understand that a hyperscale data center is the core of a fast-evolving, massive, and distributed computing network. We know how to turn an idea into a concept, and turn a concept into an industrialized solution that makes you more productive – and that can scale up quickly to keep pace with the IoT.

Capable of serving you anywhere in the world With nine data communications manufacturing plants and warehouses worldwide, we can deliver the complete portfolio of physical layer infra-structure products anywhere in the world: from data cabling, connectivity and pre-terminated assemblies, to transceivers and fiber containment systems.

As a geo-resilient operation, we know you need services around the globe. With more than 30 sales offices worldwide and more than 1,000 certified partners and value added resellers, we can provide service and support wherever you’re located.

We offer savvy cabling logisticsWe don’t just deliver the cabling, we speed up deployment: we under-stand that cabling is only one component of your data center, and we know from experience that deploying the cabling is more expensive and cumbersome than the cabling itself. Our logistics services go beyond delivering cable to a warehouse. We deliver pre-terminated, tested and custom-labeled cabling, enclosures, transceivers, pathways, etc., on time and ready for deployment.

Collaborating with customers to improve performanceWe have four competence centers worldwide (USA, UK, Belgium and Germany). Our TEK Center in New Holland, PA, USA, features two world-class R&D labs focused on applications and new materials develop-ment as well as showcases for data center and enterprise networks. Our competence centers provide insight on how to solve network challenges by allowing you to experience the latest technology, learn about emerging applications and access world class research and development.

Would you like to learn more about our services and solu-tions? Please contact us at www.nexans.com/datacenters or [email protected].

COMPLETE COVERAGE FOR ALL OF YOUR NEEDS

Page 50: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

48

We help you grow your hyperscale data center

Fix yourproblems

Scale up yourdatacenter

Industrialize yournew concepts

We like to think that we have everything you’re looking for.

people are always looking for mistakes. So we put those in here, too.

And some

Page 51: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

We help you grow your hyperscale data center

Fix yourproblems

Scale up yourdatacenter

Industrialize yournew concepts

Page 52: HYPERLANE SERVICES FOR HYPERSCALE DATA CENTERS

www.nexans.com/datacenters

NexansData Center Solutions100 Technology Park LaneFuquay-Varina, NC 27526USA