Hydro power plant
description
Transcript of Hydro power plant
![Page 1: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/1.jpg)
Turbines
1
• Water under pressure contains energy.• Turbines convert the energy in water into
rotating mechanical energy.• Impulse turbines convert the kinetic
energy of a jet of water to mechanical energy.
• Reaction turbines convert potential energy in pressurized water to mechanical energy.
![Page 2: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/2.jpg)
Selected References
• Microhydro by Scott Davis• Microhydro Design Manual by Adam
Harvey• Waterturbine.com for picohydro units• BC Hydro Handbook• Idaho National Labs
2
![Page 3: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/3.jpg)
Impulse Turbines
• Tolerate sand.• Easy to fabricate.• Efficient at wide a range
of head and flow.• A nozzle converts
pressurised water into a high-speed jet of water.
3Pelton Turbine – Canyon Industries
![Page 4: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/4.jpg)
4
Impulse Turbines• Pelton
– Low Flow– Medium to High Head
• Turgo– Medium Flow– Medium to High Head
• Crossflow– High Flow– Low to Medium Head
![Page 5: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/5.jpg)
Pelton Turbines
• At least one jet of water strike the buckets at atmospheric pressure.
• Maximum jet diameter about 1/3 bucket width.
• More jets increase flow and are used at low head.
50.61m Pelton – Dependable Turbines Ltd.
![Page 6: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/6.jpg)
Multiple Runners
• Advantages– Greater Flow– Flow control
• May be placed in the same housing or separate housings.
61000 kW Twin Pelton – Canyon Industries
![Page 7: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/7.jpg)
Turgo Turbines
7
• Similar to Pelton runner, but a more complex blade design.
• Greater flow possible.
![Page 8: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/8.jpg)
Multiple nozzles
8
• Four to six nozzles may be added before splash interference occurs.
• Power output is proportional to the number of nozzles.
![Page 9: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/9.jpg)
Spear Valves
• A spear valve changes the nozzle size without stopping the turbine.
• Expensive.
Spear Valve
9
![Page 10: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/10.jpg)
Deflectors
• Deflectors can be used to vary flow.• Usually used for emergency stop without causing
water hammer.
Deflector
10
![Page 11: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/11.jpg)
Crossflow Turbines
11
• Banki or Mitchell turbine.• Shaft oriented horizontally.• Rectangular nozzle forms the
jet.• Water strikes the blades twice.• A control vane changes jet size.
![Page 12: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/12.jpg)
Crossflow Turbines
• A draft tube increases head.• Longer blades increase flow and power.• Part flow is achieved with partition vanes.
40 kW Crossflow – Canyon Industries 12
![Page 13: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/13.jpg)
Impulse Turbine Manufacturers
• Harris Hydro - Pelton• ES&D - Turgo• Platypus - Pelton• Canyon – Pelton• Dependable – Pelton, Turgo• Tamar Designs Pty. Ltd. – Pelton, Turgo• HTS - Crossflow
13
![Page 14: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/14.jpg)
Reaction Turbines
14
• Expensive blade manufacture.• High flow rates.• More site specific than impulse.• Uses pressure drop across
turbine.• Cavitation must be avoided.• High turbine speed at low head.
![Page 15: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/15.jpg)
Reaction
• Francis– Medium Head
• Propeller and Kaplan– Low Head
• Pump as Turbine– Medium Head
15
![Page 16: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/16.jpg)
• Guide vanes may be adjusted by governor.
• Efficiency decreases as flow decreases.
• Water flow is radial from exterior to interior.
• Flow changes gradually from radial to axial.
16
Francis
![Page 17: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/17.jpg)
• Similar to ships propeller.• Has guide vanes similar to
Francis Turbine.• A Kaplan Turbine has
variable pitch blades.• Part flow efficiency is poor.
17
Propeller Turbine
Propeller Turbine – Dependable Turbines Ltd.
![Page 18: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/18.jpg)
Pump as Turbine
18
• Centrifugal pumps may be used as turbines.
• Low cost due to mass production.• No direct correlation between pump
characteristics and turbine characteristics.• Flow is fixed for a given head.• Some manufacturers have tested their
pumps as turbines.• Good for grid-tie with induction motors.
![Page 19: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/19.jpg)
Turbine application
Head (pressure)
Turbine High(30m +)
Medium Low(<10 m)
Impulse Pelton Turgo
CrossflowPeltonTurgo
Crossflow
Reaction - FrancisPump
PropellerDarius
19
![Page 20: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/20.jpg)
Other Turbines
• Aquair• Gorlov Helical Turbine• Water Wheels
– Overshot– Undershot
20
![Page 21: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/21.jpg)
Generators• Types of Generators
– Synchronous– Induction– DC generators
• Characteristics of Generators• Selecting a Generator• Voltage Regulation• Governing (speed and frequency)
– Mechanical– Electronic
21
![Page 22: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/22.jpg)
Synchronous Generator
• Used in almost all stand-alone applications.
• Single phase used up to 10 kW.• Most three phase are smaller than
equivalent single phase.
22
![Page 23: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/23.jpg)
Induction Generator
• Just an induction motor with negative slip.• Used most often with grid-tie systems.• Used by some for battery based systems.
23
![Page 24: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/24.jpg)
Induction Generator• Simple and robust.• Readily available and inexpensive.• Requires external excitation from the grid or from
capacitors.• Control is more difficult, especially for inductive loads.• It requires frequency controls if not tied to the grid
24
![Page 25: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/25.jpg)
DC Alternator
• Produces rectified alternating current.
• Readily available.• Easy to service.• A rheostat controls
excitation.
25
![Page 26: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/26.jpg)
Selecting a Generator• Type (synchronous, induction)
– Stand-alone or grid-tie• Single or Three phase
– Loads– Generator size
• Voltage– Loads– Transmission
• RPM– Size and availability
• Size26
![Page 27: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/27.jpg)
Selecting a Generator• A larger generator:
– makes up for transmission losses– is required for reactive loads.
• An oversized generator– is more efficient.– allows for future expansion.– runs cooler.
• Centripetal forces during over-speed can damage generators.
27
![Page 28: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/28.jpg)
Mechanical Governing
• Mechanical flow control is not common.– More expensive– Slower reacting– Fine for very large systems
• Mechanical deflectors are used for emergency shut down.
28Deflector
![Page 29: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/29.jpg)
Electronic Governing
• Frequency governing is used for synchronous generators.
• Voltage governing is used for induction generators
• Diversion Loads– A load must always be present.– Water heating or air heating.
• Diversion loads may be useful loads.29
![Page 30: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/30.jpg)
Diversion Controllers
• Thomson and Howe Energy Systems Digital Load Control Governor for AC.
• Thyristor based.• Does cause line noise.
30
![Page 31: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/31.jpg)
Batteries and Charge Control• Purpose of Batteries• Storage Battery Terms• Lead Acid Batteries
– Battery Voltage– Battery Capacity– Battery Cycle Life and Float Life
• Battery Charge Control– Voltage set points– Three stage charging– Equalization– Temperature Compensation
31
![Page 32: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/32.jpg)
Batteries Provide
• Peak capacity– Simultaneous loads
• Surge capacity– Motor starting
Time
Hydro PowerLoad Profile
Pow
er
PeakSurge
32
![Page 33: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/33.jpg)
Diversion Charge Controllers
• Prevent battery overcharging.• Manufacturers:
– Xantrex/Trace C-60/40/35– Applied Power Enermaxer III– Solar Converters LDR.
33
![Page 34: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/34.jpg)
34
Diversion Loads
• Heating elements– Water– Air
• Light bulbs can burn out.
![Page 35: Hydro power plant](https://reader034.fdocuments.in/reader034/viewer/2022052303/545d6d63b1af9fe9408b483a/html5/thumbnails/35.jpg)
Duty Ratings and Surge
• Inverters have both a Continuous rating and a Surge rating.
• Surge represents motor starting ability.
• Surge ability depends on input voltage.
• In general, a low frequency inverter has better surge characteristics. 35