Hydro electric
-
Upload
mohit-nainwaya -
Category
Education
-
view
199 -
download
0
description
Transcript of Hydro electric
![Page 1: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/1.jpg)
PRESENTATION OUTLINE
• Introduction to Nepal Electricity Authority
• Electrical Power System in Nepal
• Middle-Marsyangdi Hydroelectric Stations.
• Operating Principles of Hydroelectric plants.
• Hydro electric Power components
04/13/23 1
![Page 2: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/2.jpg)
INTRODUCTION TO NEPAL ELECTRICITY AUTHORITY (NEA)
04/13/23 2
• NEA is a government owned electricity provider.• It works on all the part of electrical system.
GENERATIONTRANSMISSION DISTRIBUTIONCONSUMER PRICING
![Page 3: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/3.jpg)
Electrical Power System in Nepal
04/13/23 3
• GENERATION Voltage level: 11 KV, 3 Phase, AC, 50 Hz
• TRANSMISSION (voltage stepped up) Voltage level: 110 and 220 KV, 3 Phase, HVAC,
50 Hz
• DISTRIBUTION (Voltage stepped down) Voltage level: 11KV, 3 Phase, 50 Hz feeder line
220/380 Volts at consumer end
![Page 4: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/4.jpg)
Middle-Marsyangdi Hydroelectric Stations
04/13/23 4
Established: The plant was commissioned on 14 December 2008
Features:-One of the large power houses in Nepal.-70 MW generation capacity. Two units of 35 MW.System Voltage of 11 KV.-Connected to the National grid at the voltage level of
132 KV.-The average annual energy output amounts to 398 GWh
(Power x annual operating hours)
![Page 5: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/5.jpg)
Middle-Marsyangdi Hydroelectric Stations
04/13/23 5
Middle-Marsyangdi hydro electric power station.
![Page 6: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/6.jpg)
Middle-Marsyangdi organization Chart (Technical)
04/13/23 6
![Page 7: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/7.jpg)
Operating Principles of Hydroelectric Stations
04/13/23 7
A typical Hydropower Station
![Page 8: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/8.jpg)
Operating Principles of Hydroelectric Stations
04/13/23 8
1. Water flowing through Marsyangdi river is dammed so that required water level is maintained to pass the water to the intake gates. Spillways are operated to prevent the flooding.
2. Water then passes through intake gates to trash rack which prevents large debris from entering into the tunnel. The trash racks are cleaned periodically using cranes.
![Page 9: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/9.jpg)
Operating Principles of Hydroelectric Stations
04/13/23 9
3. Water then enters the desander where the sand present in water is removed by sedimentation. The collected sand is pumped back into the river through flushing channel. 4. Water almost free from sand then passes through tunnel to surge tank which prevents water hammering in penstock pipe and maintain constant flow through it.
![Page 10: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/10.jpg)
Operating Principles of Hydroelectric Stations
04/13/23 10
5. Water then enters the penstock after passing through the valve chamber and in the penstock; the discharge of water is measured. 6. The penstock then bifurcates to supply water for each unit. Each bifurcation is provided with a bypass valve for balancing the pressure during maintenance.
![Page 11: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/11.jpg)
Operating Principles of Hydroelectric Stations
04/13/23 11
7. Water then passes through the expansion pipe followed by main inlet valve (MIV) and enters the spiral casing. 8. Water is guided by the adjustable guide vanes which then impact the runner, thus rotating the turbine.
![Page 12: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/12.jpg)
Operating Principles of Hydroelectric Stations
04/13/23 12
9. This rotates the turbine shaft which is coupled with the generator which generates electricity based on the principles of electromagnetism. 10. The current so generated is passed to the transformers which step up the voltage to provide supply to the national grid.
![Page 13: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/13.jpg)
Hydropower components
04/13/23 13
1. Civil Structures like Dam, Opening etc
2. Some Mechanical Components like Turbine
Governor, valves etc
3. Electrical Components likePower Generator
Power TransformerExcitation System
Switch gear and Protection System etc
![Page 14: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/14.jpg)
Civil Structures
04/13/23 14
A typical dam and opening in Hydroelectric
stations at the Middle Marsyangdi MMHPS
![Page 15: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/15.jpg)
Mechanical Equipments (only some are shown)
04/13/23 15
1. Francis Runner 2. Butterfly valve Opened
![Page 16: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/16.jpg)
Mechanical Equipments (only some are shown)
04/13/23 16
3. Bypass valve 4. Guide Bearing
![Page 17: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/17.jpg)
Electrical Equipments
04/13/23 17
1. Power Generator
Generator Specifications at
MMHPS
: Type: 3-Phase, 2 unit, Synchronous
: Power: 35 MW each unit.
: Voltage level: 11 KV
: Frequency: 50 Hz
![Page 18: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/18.jpg)
Electrical Equipments
04/13/23 18
1. Generator Principles
1-Phase Three Phase Waveforms
Faraday’s law of electromagnetic induction
![Page 19: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/19.jpg)
Electrical Equipments
04/13/23 19
Brushless Excitation System
To provide the excitation field (magnetic fields) needed by
synchronous generator.
11 KV/180 volt excitation system is used at MMHPS
![Page 20: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/20.jpg)
Electrical Equipments
04/13/23 20
Power Transformer (Step Up)
Specification:
: 11 KV Primary (generation voltage level)
: 132 KV (Secondary national grid voltage level)
: Delta/Star type
: Power rating 42 MVA
: Purpose: For national grid connection.
![Page 21: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/21.jpg)
Electrical Equipments
04/13/23 21
Station and local Transformers (Step down)Specification:
: 132 KV Primary (National Grid level)
: 33 KV (Secondary Station level)
: Star/Delta type
: Power rating 5 MVA
: Purpose: Local Power Supply through Damauli-Udipur 33kv line
![Page 22: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/22.jpg)
Thanks for your attention!
04/13/23 22
![Page 23: Hydro electric](https://reader035.fdocuments.in/reader035/viewer/2022062220/55890faed8b42acf788b4626/html5/thumbnails/23.jpg)
Questions!
04/13/23 23