HYDRA-POINT™ Volumetric Karl Fischer Reagents · PDF fileFor stabilizing the pH during...

2
PRODUCT PROFILE | www.avantormaterials.com | 1 Productprofile P YRIDINE - FREE FOR SAFE , EASY H 2 O DETERMINATION The product line with all the right components No matter what your requirements are for volumetric systems, HYDRA-POINT Karl Fischer reagents make water determination easy and trouble free. They are pyridine-free and specially formulated for existing application procedures to give you consistent, reliable results for all types of samples. Key features of HYDRA-POINT reagents are: • (Pyridine-free)—The use of pyridine in the laboratory has well recognized hazards, in addition to its unpleasant odor. That is why our HYDRA-POINT products do not contain pyridine. • Productivity—HYDRA-POINT reagents are formulated to reach each endpoint quickly, accurately, and with reproducibility, allowing you to perform more titrations in less time. • Accuracy—Comparison studies prove HYDRA-POINT reagents have titers that are more stable with less drift, helping you save time and reduce reagent usage. HYDRA-POINT titrants and solvents guarantee fast equilibration within the Karl Fischer reaction vessel, giving greater laboratory efficiency and speed of analysis. T WO - COMPONENT HYDRA-POINT K ARL FISCHER R EAGENTS With two-component reagents, the reactants are in two separate solutions. The burette is filled with HYDRA-POINT titrant and the reaction vessel contains HYDRA-POINT solvent. First, the HYDRA-POINT solvent is titrated to dryness with HYDRA-POINT titrant. Then the sample is added and the water content is analyzed by titration. 8855 HYDRA-POINT Solvent G: Pyridine-free solvent component for volumetric Karl Fischer titration (use with product 8844 and 8845). 8844 HYDRA-POINT Titrant 5: Titrant component (5 mg H 2 O per mL) for volumetric Karl Fischer titration (use with product 8840 or 8855). 8845 HYDRA-POINT Titrant 2: Titrant component (2 mg H 2 O per mL) for volumetric Karl Fischer titration (use with product 8840 or 8855). ONE - COMPONENT HYDRA-POINT K ARL FISCHER R EAGENTS In one-component systems, all the reactants are present in the HYDRA-POINT composite reagent. The sample is put into a methanol solution in the titration vessel. Then the HYDRA- POINT composite is titrated into the titration vessel until the endpoint is reached. 8890 HYDRA-POINT Composite 5: Pyridine-free, one-component reagent (5 mg H 2 O per mL) for volumetric Karl Fischer titration. HYDRA-POINT™ Volumetric Karl Fischer Reagents

Transcript of HYDRA-POINT™ Volumetric Karl Fischer Reagents · PDF fileFor stabilizing the pH during...

Page 1: HYDRA-POINT™ Volumetric Karl Fischer Reagents · PDF fileFor stabilizing the pH during Karl Fischer titration. The buffer capacity is 5 mmol acid per mL. 8898 HYDRA-POINT Dry Methanol:

P R O D U C T P R O F I L E | www.avantormaterials.com | 1

Productprofile

Pyridine-free for safe, easy H2o determination

The product line with all the right components

No matter what your requirements are for volumetric systems,

HYDRA-POINT Karl Fischer reagents make water determination

easy and trouble free. They are pyridine-free and specially

formulated for existing application procedures to give you

consistent, reliable results for all types of samples. Key features

of HYDRA-POINT reagents are:

• (Pyridine-free)—The use of pyridine in the laboratory has

well recognized hazards, in addition to its unpleasant odor.

That is why our HYDRA-POINT products do not contain

pyridine.

• Productivity—HYDRA-POINT reagents are formulated

to reach each endpoint quickly, accurately, and with

reproducibility, allowing you to perform more titrations in

less time.

• Accuracy—Comparison studies prove HYDRA-POINT

reagents have titers that are more stable with less drift,

helping you save time and reduce reagent usage.

HYDRA-POINT titrants and solvents guarantee fast

equilibration within the Karl Fischer reaction vessel, giving

greater laboratory efficiency and speed of analysis.

two-comPonent Hydra-Point Karl fiscHer reagents

With two-component reagents, the reactants are in two

separate solutions. The burette is filled with HYDRA-POINT

titrant and the reaction vessel contains HYDRA-POINT solvent.

First, the HYDRA-POINT solvent is titrated to dryness with

HYDRA-POINT titrant. Then the sample is added and the water

content is analyzed by titration.

8855 HYDRA-POINT Solvent G:

Pyridine-free solvent component for volumetric Karl Fischer

titration (use with product 8844 and 8845).

8844 HYDRA-POINT Titrant 5:

Titrant component (5 mg H2O per mL) for volumetric Karl

Fischer titration (use with product 8840 or 8855).

8845 HYDRA-POINT Titrant 2:

Titrant component (2 mg H2O per mL) for volumetric Karl

Fischer titration (use with product 8840 or 8855).

one-comPonent Hydra-Point Karl fiscHer reagents

In one-component systems, all the reactants are present in

the HYDRA-POINT composite reagent. The sample is put into

a methanol solution in the titration vessel. Then the HYDRA-

POINT composite is titrated into the titration vessel until the

endpoint is reached.

8890 HYDRA-POINT Composite 5:

Pyridine-free, one-component reagent (5 mg H2O per mL) for

volumetric Karl Fischer titration.

HYDRA-POINT™ Volumetric Karl Fischer Reagents

Page 2: HYDRA-POINT™ Volumetric Karl Fischer Reagents · PDF fileFor stabilizing the pH during Karl Fischer titration. The buffer capacity is 5 mmol acid per mL. 8898 HYDRA-POINT Dry Methanol:

8891 HYDRA-POINT Composite 2:

Pyridine-free, one-component reagent (2 mg H2O per mL) for

volumetric Karl Fischer titration.

8892 HYDRA-POINT Composite 5K:

Pyridine-free, one component reagent for volumetric Karl

Fischer titration of ketones (use with product 8898).

more quality Hydra-Point Karl fiscHer Products from J.t.BaKer

8899 HYDRA-POINT Buffer:

For stabilizing the pH during Karl Fischer titration. The buffer

capacity is 5 mmol acid per mL.

8898 HYDRA-POINT Dry Methanol:

Dry methanol (water max. 0.01%) for Karl Fischer titration.

For more detailed information, prices and ordering, please

contact your local distributor or our Customer Service

department.

Phillipsburg, NJ 9001: 2008 & 14001: 2004Paris, KY 9001: 2008Mexico City, Mexico 9001: 2008Deventer, the Netherlands 9001: 2008 & 14001: 2004 & 13485: 2003Selangor, Malaysia 9001: 2008

Ordering Information and AssistanceCustomer Service and Technical Servicetoll free: +1-855-AVANTOR (+1-855-282-6867)outside of u.s. tel: +1-610-573-2600fax: +1-610-573-2610 e-mail: [email protected] www.avantormaterials.com

AskAvantor™Our Web site features ASK Avantor,™ which includes live chat capabilities with customer service representatives. www.avantormaterials.com/askavantor

Corporate HeadquartersAvantor Performance Materials, Inc. 3477 Corporate Parkway Suite #200 Center Valley, PA 18034 USA

About Avantor™ Performance MaterialsAvantor Performance Materials manufactures and markets high-performance chemistries and materials around the world under several respected brand names, including the J.T.Baker®, Macron Fine Chemicals™, Rankem™, Diagnova™, BeneSphera™, and POCH™ brands.

Avantor products are used in a wide range of industries. Our biomedical and life science solutions are used in academic, industry and quality control laboratories for research, pharmaceutical production and medical lab testing, while our electronics solutions are used in the manufacturing of semiconductors and flat panel displays. Based in Center Valley, Pennsylvania (USA), Avantor is owned by an affiliate of New Mountain Capital, LLC.

For additional information please visit www.avantormaterials.com or follow www.twitter.com/avantor_news

Lit Number: 9002 ©2012 Avantor Performance Materials, Inc. All rights reserved. Trademarks are owned by Avantor Performance Materials, Inc. or its affiliates unless otherwise noted.

Worldwide Locations• China • Malaysia • North America• India • Mexico • Taiwan• Korea • The NetherlandsFor contact information at these locations, visit www.avantormaterials.com/Support/Contact-Us/Worldwide-Directory.aspx