Hyde Wingman Owner's Manual
description
Transcript of Hyde Wingman Owner's Manual
2
TABLE OF CONTENTS3 Specifications&Re-ArmKit4 CheckInflationStatusIndicators5 Arming/Re-ArmingInstructions6 DonningInstructions7 HowtoInflateYourWingman8 HowtoInflateYourWingmancontd.9 Deflating/Re-Packing10 Re-Packingcontd. 11 NotesonProperZipperUse12 Use,Care,&MaintenanceInstructions13 TestingYourWingman(How&Why)
ContactHydewithanyquestionsorconcernsat:[email protected]
(314)546-4894911WashingtonAveSte.420
St.Louis,MO63101
WARNING: THIS IS NOT A US COAST GUARD APPROVED LIFE VEST AND DOES NOT COUNT TOWARDS CARRIAGE REQUIREMENTS
THISPRODUCTDOESNOTHAVEANYSTATEDORIMPLIEDWARRANTIESCONCERNINGITSPERFORMANCE;DESIGNEDFOREXPERIENCEDSWIMMERSONLYANDWILLNOTPROTECTANY
WEARERSFROMDROWNINGORINJURY
THISVESTISDESIGNEDFORADULTS18YEARSOFAGEANDWEIGHING80LBSORMORE
+SPECIFICATIONS
USERWEIGHT:MORETHAN80LBS(36KG)DESIGNEDFORADULTUSE
CO2CYLINDER:24GRAM,½INCHTHREADEDHALKEYROBERTS840MANUALINFLATORFOR1/2INCHCYLINDER
REARMINGKIT:HYDE1.0&2.4RE-ARMKITS
USEONLYCOMPATIBLEHYDEREARMINGKITSWITHYOURWINGMAN1.0ORWINGMAN2.4.REARMINGKITSANDPARTSARENOTINTERCHANGEABLE.SUBSTITUTIONMAYDAMAGEORCAUSEYOURWINGMANTOMALFUNCTION.
DO NOT INFLATE VEST WITH CO2 UNLESS YOU ARE WEARING IT PROPERLY WITH STRAPS SECURELY FASTENED. IF YOU NEED TO DEPLOY VEST WITHOUT WEARING IT, OPEN ZIPPERED COMPARTMENT COMPLETELY PRIOR TO INFLATING WITH CO2. WHEN ORALLY INFLATING, OPEN ZIPPERED COMPARTMENT COMPLETELY PRIOR TO INFLATION, THIS WILL ALLOW YOU TO EASILY ORALLY INFLATE BLADDER COMPLETELY.
3
1. Where and How to Check Inflation System Status Indicators: Itisnecessarytoopenthebackcompartmentcoveringtheinflatortodeterminewhetherthedeviceisarmed;toopenthiscompartmentfollowinstructionsonpage11.IfinflatorindicatorshowsredorifyouknowtheCO2canisterisempty,re-armaccordingtoinstructionsonpage5.YourWingmanmustbearmedpriortouse.
Is your Wingman in Good and Serviceable Condition?CheckyourWingmanbetweenoutingstobesurethatitisproperlyarmed;thatitisfreeofrips,tearsorholes;thatallseamsaresecurelysewn;andthatthefabric,strapsandhardwarearestillstrong.InspecttheinflatableportionofthePFDinaccordancewithcareandmaintenanceinstructionsonpage12.
4
Hal
key-
Rob
erts
840
Ser
ies
Man
ual I
nfla
tor
Rea
rm In
stru
ctio
ns
C84
0RE
ARM
_Rev
.A
Ste
p 1: U
nscr
ew u
sed
CO
2 cy
linde
r in
a co
unte
r-cl
ockw
ise
dire
ctio
n an
d im
med
iate
ly d
isca
rd.
Do
not
inse
rt n
ew c
ylin
der a
t thi
s tim
e. T
o av
oid
conf
usio
n la
ter i
n th
e re
arm
ing
proc
ess,
we
sugg
est y
ou th
row
aw
ay th
e ol
d C
O2 cy
linde
r now
.
Ste
p 2:
Clo
se m
anua
l inf
lato
r arm
with
in in
flato
r bod
y
and
care
fully
inse
rt a
new
gre
en in
dica
tor t
ab s
o th
at it
fu
lly c
over
s th
e re
d se
mi-c
ircle
on
the
body
.
Ste
p 3:
Loo
k in
to th
read
ed c
ylin
der r
ecei
ver a
nd
view
the
gask
et.
If w
orn,
repl
ace
with
Hal
key-
Rob
erts
849
AM
gas
ket f
or ⅜
" rec
eive
r or 8
49A
ML
for
½" r
ecei
ver.
Ste
p 4:
Ins
pect
the
face
of t
he n
ew c
ylin
der.
Be
sure
it
is s
moo
th a
nd h
as n
o ho
les
or s
crat
ches
. Th
ere
is a
gr
oss
wei
ght o
n th
e cy
linde
r. If
you
hav
e an
y qu
estio
n ab
out c
ylin
der i
nteg
rity,
wei
gh th
e cy
linde
r on
a sm
all
scal
e, s
uch
as a
pos
tage
sca
le.
Com
pare
the
wei
ght
prin
ted
on th
e cy
linde
r to
the
actu
al w
eigh
t. If
they
do
no
t mat
ch, g
et a
noth
er c
ylin
der.
Ste
p 5:
Scr
ew n
ew c
ylin
der i
n a
cloc
kwis
e di
rect
ion
firm
ly
into
the
infla
tor.
Do
not o
ver-
tight
en, b
ut e
nsur
e th
e
fit is
tigh
t.
Ste
p 6:
Che
ck th
e in
flato
r arm
ing
indi
cato
r eve
ry
boat
ing
trip
. It
will
tell
you
if th
ere
is a
nee
d fo
r ser
-vi
ce.
Che
ck th
e cy
linde
r fac
e re
gula
rly to
ens
ure
it is
no
t pun
ctur
ed.
Ser
vice
Indi
cato
r — S
tep
6
If
gree
n, u
nit i
s op
erab
le.
If re
d, s
top
and
serv
ice
unit.
Leve
r St
ep 2
Cylin
der F
ace
Step
4
Gree
n Ind
icator
Tab
St
ep 2
Thre
aded
Cyli
nder
Re
ceive
r St
ep 3
Step
5
CO2 C
ylind
er
Step
1 St
ep 5
Red S
emici
rcle
Step
2
ARMING/RE-ARMING INSTRUCTIONS
5
DONNING INSTRUCTIONS1.Putheadthroughholewithcenterzipperinfront(zippersandHyderubberlabelsshouldbefacingout)2.Pullstrapsunderarmsandfastenbucklestoconnectbackportionofvesttofrontportionofvest(fastenbucklesbehindbackifyouownaWingman1.0or2.4withbackbuckles;fastenbucklesonsidesifyouownaWingman1.0or2.4withsidebuckles)3.Tightenstrapsforasnugfit4.Ensureripcordhandleisaccessibleonfrontleftchest
+IT IS IMPERATIVE THAT THE VEST IS PROPERLY ADJUSTED TO FIT THE PERSON WEARING IT. AN INCORRECT FIT, OR IMPROPER DONNING CAN INHIBIT THE EFFECTIVENESS OF THE DEVICE, OR RESULT IN INJURY. DO NOT WEAR THE VEST UNDERNEATH ANY TYPE OF CLOTHING, SERIOUS INJURY MAY RESULT.
6
How to Inflate Your WingmanManual Inflation (CO2 Inflation)THEWINGMANISMANUALLYINFLATEDBYGRASPINGTHERIPCORDHANDLEONTHELEFTCHESTANDPULLINGSHARPLYDOWNWARD.DO NOT INFLATE VEST WITH CO2 UNLESS YOU ARE WEARING IT PROPERLY WITH STRAPS SECURELY FASTENED. IF YOU NEED TO DEPLOY VEST WITHOUT WEARING IT, OPEN ZIPPERED COMPARTMENT COMPLETELY PRIOR TO INFLATING WITH CO2. WHEN ORALLY INFLATING, OPEN ZIPPERED COMPARTMENT COMPLETELY PRIOR TO INFLATION.
PullhandledownwardswiftlyOral Inflation 1.AccessingOralInflationTubeTHEORALINFLATIONTUBEISLOCATEDINSIDETHEZIPPEREDCOMPARTMENTONTHEWEARER’SRIGHTSIDE.TOACCESSTHEORALINFLATIONTUBE,PULLUPONBOTTOMOFOUTERLAYEROFFRONTRIGHTPORTIONOFVESTTOPEELOPENZIPPER,THEWEAKPOINTSAREATBOTHENDSOFZIPPERANDCENTEROFBACK,INORDERTOOPENTHEVESTANDACCESSORALINFLATIONTUBE,PEELAPARTZIPPERATONEOFTHESEPOINTSANDACCESSBLADDER.
7
2.InflatingwithOralTubeOncetheuserhasaccessedtheoralinflationtubetheusermustmakesurethetubeisintheunlockedpositionpriortoinflating.Tounlockthetubetheusermustscrewdownthelockingringsothatthemouthnozzlecanbede-pressed.Ifthelockingringisintheuppositionandpreventsthemouthnozzlefrombeingdepressedthewearerwillnotbeabletoorallyinflatethebladderandmustunlockthetube.Oncethetubeisunlockedtheusersimplydepress-esthemouthpiecewhileblowingintothebladderuntilthebladderisfirm.
UNLOCKED
NOTE:OralinflationcanbeusedtotestforairleakageorasabackupintheeventthattheCO2cylinderfailstooperate.CO2gaspermeatesthebladdermorequicklythanwithair,andthereforeoralinflationcanbeusedtorefillthebladderintheeventthewearerisinthewaterforanextendedperiod.DONOTFULLYINFLATETHEBLADDERORALLYANDTHENINFLATEWITHCO2CYLINDER,ASBLADDERCOULDINCURDAMAGE
8
HowtoDeflateYourWingmanTODEFLATEYOURWINGMANUNLOCKTHEORALINFLATIONTUBEBYSCREWINGDOWNLOCKINGRING,THENDEPRESSMOUTHNOZZLEWHILEPUSHINGAIROUTOFBLADDER,GENTLYSQUEEZEALLTHEAIROUTOFTHEBLADDER.IFTHEBLADDERHASINLFATEDWHILEBEINGWORN,ITMAYBENECESSARYTOPARTIALLYDEFLATETHEBLADDERTOREMOVEIT.THE BLADDER WILL BE DIFFICULT TO FOLD AND REPACK PROPERLY IF NOT COMPLETELY DEFLATED.
PRACTICEDEPLOYING,WEARING,ANDADJUSTINGYOURWINGMANINTHEWATERINORDERTOBEPREPAREDFORANEMERGENCY.PRACTICE UNTIL YOU HAVE COMPLETE CONFIDENCE IN THE PERFORMANCE OF YOUR WINGMAN
Re-PackingYourWingmanBEFOREREPACKINGYOURWINGMAN,MAKESURETHATTHEDEVICEHASBEENDEFLATEDANDREARMEDACCORDINGTOTHEINSTRUCTIONSINTHISMANUAL.
2.DeflateBladderCompletely
9
NOTESONRE-PACKING:-Priortozipping,pullapartzippercompletelyandensureitiscompletelyseparated,thenreturnzipperpulltostartpositionandbegintozip(page11note1)-Foldbladderintothirdsandtuckincompartmentwhilezipping-Ensurezipperpullrunsoffendofoutertrackandgoestostopblock(page11note3)
10
FOLDBLADDERINTHIRDS
NOTES ON RE-PACKING AND PROPERLY USING HYDE’S PATENT PENDING TRIPLE BURSTING ZIPPER1.USERMUSTCOMPLETELYUNDOANDSEPARATEZIPPERTORE-ZIPWINGMAN,IFYOURWINGMANBECOMESPARTIALLYUNZIPPED,OPENTHEENTIRECOM-PARTMENTANDRESETTHEZIPPERPULLTOTHEBLOCKANDSTARTZIPPINGFROMTHEBEGINNING2.GENTLYZIPPULLOVERGAPINZIPPERATCENTEROFBACK3. ALWAYS ZIP THE PULL COMPLETELY TO THE STOPPER AT THE END OF TRACK (WHEN DONE PROPERLY THE ZIPPER PULL WILL ONLY BE CONNECTED TO THE INSIDE ZIPPER TRACK), THIS ENSURES THAT UPON DEPLOYMENT THE ZIPPER CAN SEPARATE AT THIS END, IF ZIPPER PULL IS NOT PULLED ALL THE WAY TO END AND REMAINS CONNECTED TO BOTH TRACKS INFLATION CAN BREAK THE ZIPPER AND IS NOT COVERED BY WARRANTY. ALWAYS ZIP YOUR WINGMAN COMPLETELY AND CHECK THAT THE ZIPPERS CAN SEPARATE. 3 FUNCTIONAL BURST POINTS ARE CRUCIAL TO THE FUNCTIONALITY AND LONGEVITY OF YOUR WINGMAN.4.TOQUICKLYOPENBLADDERCOMPARTMENT,SIMPLYPULLUPWARDSONBACKTABANDPEELOPENZIPPER1. 2.
3. 4.
11
USE, CARE, AND MAINTENANCE INSTRUCTIONS
USE:Thereisadangerofbodilyinjuryifthisdeviceisnotdonnedcorrectly.Besurethelogofacesoutward.ThisPFDmustbeinflatedtofloatthewearer.Clothingcanaffecttheperformanceofthisdeviceinthewater.Toreduceriskofdrowningbeforedonningcheckthatdeviceisproperlyarmedandpackedinaccordancewiththisowner’smanualandthatfullycharged24gram½inchthreadedCO2cartridgeisinplace.+Fastenallclosuresandadjustforsnugfit+Donotfastendevicetoboat+Thisdevicerequiresrearmingaftereachinflation.AlwayshaverearmingkitstoserviceyourinflatablePFDsoruseinflated+CaremustbetakentoavoiddamagefromabrasionandsharpobjectsPrecautionsforUseinFreezingTemperatures
ThegasinaCO2cartridgeexpandsinhotweatherandcontractsincoldweatherUnderfreezingconditionstheCO2fillsmoreslowlyandachieveslessbuoyancy.ThiscanbecompensatedbypartlyinflatingthePFDwithoneortwobreathsofairthroughtheoraltube.
CAUTION:DONOTfullyinflatebyblowingintheoraltubeandtheninflatewiththeCO2cylinder.RepeatedCO2inflationafteroralinflationmaydamagethePFD.
CARE AND MAINTENANCE INSTRUCTIONS (Continued)
1.Beforeeachoutingunscrewthecylindertobesurethatithasnotbeenpierced.Replacecylinderifpierced.Rearmperinstructionsinthismanual.Makesurecylinderistightlyscrewedin.Cylindersmayunscrewoveraperiodofuse.2.VisuallyInspectandCheckforLeaks.TOcheckforleaks,removecylinder,orallyinflatethedeviceuntilfirm,andleaveovernight.Thereshouldbenonoticeablelossoffirmness.Performthisleakagetestatthebeginningofeachseasonandatleasteverytwomonthsthereafterifyouarealighttomoderateuser,moreoftenifyouuseyourWingmanfrequently.3.RearmingInstructions:Page5.4.RepackingInstructions:Page9,10,&11.5.TheCO2cartridgemaybeusedONLYONETIMEtoinflatetheWingman.6.UseonlytheREARMINGKITindicatedforyourWingmanModel.SeePage3.7.Storeinwell-ventilatedareaawayfromdirectsunlight. -Handwashinclearwaterandhangtodry -Donotdrycleanorusedsolvent-basedcleaners -Aftereachsubmersioninwater,unzipdevice,unfoldbladder andrinseoffbyhandinfreshwater,hangdryinwellventilated areaawayfromdirectsunlightorchemicalexposuretoprevent moldordeterioration
Each Wingman purchase comes with 2 rearming kits, use the first to practice inflating the Wingman and growing comfortable with how it works, it is critical to know how your device works before you find yourself in an emergency.
12
How and Why to test your Wingman?InflateyourWingmanandtryitoutinthewaterto:Makesureitfloatsyou:Comfortably(whenwornproperly),Adequatelyforexpectedwaveconditions(bodyshapes/densitiesaffectperformance)Makesureitworks:Aflowofbubblesshouldnotappear,ItshouldinflatequicklyandeasilyLearnhowitworksby:ActivatingtheCO2inflationsystem,RearmingtheCO2inflationsystem,UsingtheOralInflationTubeHyde recommends that you use the first rearming kit to test the inflation system and the second to arm the device for use. How do you test your Wingman using the Manual Inflator?1.TotestyourWingmanyouwillneed: +YourfullyarmedWingman +RearmingKitapprovedforyourWingman2.PutontheWingman3.Actuatetheinflationsystembyjerkingfirmlydownwardontheripcordhandle.TheWingmanshouldinflatewithin5seconds.4.Getintoshallowwater,justdeepenoughthatyoucanstandwithyourheadabovethesurface.5.SeeiftheWingmanwillfloatyouonyourbackorjustslightlybackofvertical.Inarelaxedfloatingposition,verifythatyourmouthiswellabovethewater’ssurface.Notetheeffectofwhereyouholdyourlegsonhowyoufloat.6.GetoutofthewaterandremovetheWingman.RemovetheusedCO2cylinderfromtheWingmaninflator.CompletelydeflatetheWingmanusingtheoralinflator.7.LettheWingmandrythoroughly.REARMandREPACKtheWingmaninaccordancewiththeinstruc-tionsinthismanual.How do you test your Wingman using the Oral inflator?1.TotestyourWingman,youwillnotneedanysparepartsorrearmingkits2.RemovetheCO2cylinder,topreventinadvertentactivationofthemanualinflationsystemwhichcouldpotentiallydamagethebladder.Inspectthethreadedendtoconfirmthatitisun-used.3.PutontheWingman4.Getintotheshallowwater,justdeepenoughthatyoucanstandwithyourheadabovethesurface.5.Ifyouareaweakswimmerornon-swimmer,inflatetheWingmanpartiallysothatyouaresupportedwellenoughtobeabletocompleteinflationwithouttouchingbottom,eitherorallyormanually.Notethislevelofinflationbecauseitistheminimumneededforyoutosafelyusethisdevice.6.FullyinflateWingmanusingtheOralinflator.7.SeeiftheWingmanwillfloatyouonyourbackorjustslightlybackofvertical.Inarelaxedfloatingposition,verifythatyourmouthiswellabovethewater’ssurface.Notetheeffectofwhereyouholdyourlegsonhowyoufloat.8.GetoutofthewaterandremovetheWingman.CompletelydeflatetheWingmanusingtheoralinflator.9.LettheWingmandrythoroughly.REARMandREPACKtheWingmaninaccordancewiththeinstruc-tionsinthismanual.Wear your WingmanInapproximately80percentofallboatingfatalitiesthevictimswerenotwearingaPFD.Mostfatalaccidentshappenoncalmsunnydays.ThisinflatablevestismuchmorecomfortabletowearthanotherPFD’s.GetintothehabitofwearingthisWingman.Non-swimmersandchildrenespeciallyshouldwearahybridornon-inflatablePFDatalltimeswhenonornearthewater.EnsurethatyouadheretoUSCGPFDcarriagerequirementswhenonthewater;thisdevicedoesNOTcounttowardscarriagerequirements.
Contact HYDE with any questions or if you need additional information at [email protected] or visit the Hyde website (www.hydesportswear.com) for more information.
13