Document
-
Upload
alfredo-poluzzi -
Category
Documents
-
view
214 -
download
0
description
Transcript of Document
The New GMI Portable Gas Detector
ENSURES THAT
“I’LL BE BACK”
Your robust, lightweight, flexible Passport to Safe Entryinto and Exit from confined spaces.
• Brilliant Visual Alarm – 360° distinct alarm level, flash rates prioritised
• Ultra loud Audible Alarm. Penetrating 95dBA
• Plug ‘n’ Play Sensor Technology with an extensive range of gas sensors
• A unique combination of Pump Diffusion sampling. Specifically designed for pre-entry and post-entry applications.
• A robust, moulded, rubberised casing guaranteeing Hi-Viz and Hi-Impact resistance
• International Certification and Conformance
DESIGNED FOR US BY OUR CUSTOMERS
High capacity plug-in diaphragm pump30 metre remote sampling capability
Robust Belt Clip
Rubber moulded centre chassisproviding excellent shock resistance
High intensity LEDs
Single PCB
PiercingAudible alarm
Sensor Grille
Hydrophobicwater barrierprotection
SampleQuickConnect
Rubber mouldingPush-fit sensorsNo O-rings
Unique rubberisedplastic mouldings- Integrally impactresistant(No carryingcase required)
Menu screen
Hi-viz LEDs
5 Gas Version
Battery
Set-up andcalibrationfunctions only
SensorOptions
A)WithPCB -Plug ‘n’Play
B) WithoutPCB -Plug ‘n’calibrate
Alarm Table•• Two levels of
instantaneous alarm
• STEL
• LTEL (TWA)
• Battery fault
• Sample fault
• Zero fault
• Sensor fault
• All individually distinct
ActualSize
ActualColour
Quick connectsampling
SensorGrille
95 decibelaudiblealarm
Simplesinglebuttonoperations
The New GMI Portable Gas Detector
Secure Battery Lock
SpecificationsPhysical PropertiesWeight: 0.4 kgDimensions: 140 x 85 x 45 mm
EnvironmentTemperature Limits -20oC to + 50oCHumidity: 0 to 95% R.H. non-condensing
PerformanceComplies with:EN 61779 (Flammable)EN 50104 (Oxygen)EN 45544 (Toxic)
Certification
ATEX II 2 G EEx iad IIC T3/T4
IEC Ex iad IIC T3
UL 913 Class I, Div 1 Groups ABCD
EC Type Examination Certificate MED
As an ISO 9001 approved company, GMI Ltd’s quality assuranceprogrammes demand the continuous assessment and improvement ofall GMI products. Information in this leaflet could thus change withoutnotification and does not constitute a product specification. Please contactGMI or their representative if you require more details.
Copyright © Gas Measurement Instruments Ltd. 2005. All rights reserved.
Part Number 99310 Issue 9 06/04/09
AccessoriesStandard Accessories Part No.(Hard) Carry Case 66349Hand Aspirator 66123Sample Line (per metre) 66118Hand Aspirator c/w 3.0 metres 66478
Tygon Tubing & Connector3.0 metres Tygon Tubing & Connector 66136Neck Harness with Clip 66028Body Harness with Clip 66546Probe Assembly 66017Ball Float 66545Battery / Sensor Grille Key (2mm.A/F) 66166Inlet Filter Key (1.5mm.A/F) 66165Long Duration (NiMH) Rechargeable 66056
Battery PackFast Charge (NiMH) Battery Pack 66335CD ROM (Instruction Manual) 66203
Configuration and Field Calibration
Standard Charger Part No.Charger (Universal Plug) 661405-Way Standard Charger 66200
c/w Universal Plug PSU10-Way Standard Charger 66207
c/w Universal Plug PSU12V / 24V Vehicle Charger Lead 66206
Fast Charger Part No.Fast Charger (Universal Plug) 6651310-Way Fast Charger c/w PSU 66516
select cable from following list:UK Mains Cable 30061USA Mains Cable 13439Euro Mains Cable 31048Australian Mains Cable 12020
Add-on Charging Module / Max of 9 66514(use with 66516)
Fast Charger & Datalogging Package 66510c/w Communications & Universal Plug)
Communications Options Part No.Data Downloading Software 66208
c/w Communications & User InstructionsData Downloading Software 66300
c/w Charger (Universal Plug)V!SACAL (Calibration) Software 66445
c/w Communications & User InstructionsV!SACAL (Calibration) Software 66448
c/w Charger (Universal Plug)V!SACAL & Datalogging Software 66500
c/w Communications & User InstructionsV!SACAL & Datalogging Software 66501
c/w Charger (Universal Plug)USB Adaptor (for above items) 66209
Note: The Communications Adaptor replaces the batterypack while calibrating or downloading data from theinstrument, therefore a standard charger, as listed, isrequired to power the instrument.
HEAD OFFICE: Inchinnan Business Park, Renfrew, PA4 9RG, Scotland, U.K.
Tel: +44 (0) 141-812 3211Fax: +44 (0) 141-812 7820
www.gmiuk.come-mail: [email protected]
SERVICE / REPAIR CENTRE: 25 Cochran Close,Milton Keynes, MK8 OAJ, England, U.K.
Tel: +44 (0) 1908 568867Fax: +44 (0) 1908 261056
IF YOU REQUIRE A QUOTATION FOR ANY PARTICULAR INSTRUMENT ANDASSOCIATED ACCESSORIES, PLEASE COMPLETE ORDERING REQUIREMENTCOLUMN THEN ACCESSORIES TICK BOXES
Ordering RequirementParent Instrument
Battery Type Code No.Alkaline (Dry Cell) 1
Long Duration NiMH 3
Fast Charge NiMH 5(Fast charger required)
Notes:• Alkaline (Dry Cell) provides up to 24 hours
operation without pump, or 17 hours withpump.
• Both Long Duration and Fast Chargerechargeable batteries provide up to 20hours operation without pump, or 14 hourswith pump.
Pump Code No.Yes 6No 7
Datalogging Code No.Yes 8No 9
Sensors Range Code No.
LEL (Std.) 0 - 100% ALEL (Unfiltered) 0 - 100% A1LEL (Carbon Cloth) 0 - 100% A2O2 0 - 25% BH2S 0 - 100 PPM CCO 0 - 1000 PPM DH2S / CO As items C & D ESO2 0 - 30 PPM FCL2 0 - 10 PPM GNO2 0 - 20 PPM HNH3 0 - 100 PPM JNO 0 - 300 PPM NCO2 0 - 5% PLEL (Infrared) 0 - 100% RPID Variable PPM U(Depending on Volatile Organic Compounds)
Note 1: A five gas version is only possible whentwo of the gases are H2S and CO (i.e. sensor E)Note 2: Each instrument is supplied completewith User Handbook, Battery / Sensor GrilleKey, Inlet Filter Key, (integral) Belt Clip andCalibration Certificate.Note 3: If a long duration (NiMH) rechargeablebattery type is selected, a Standard Charger isalso included.
6 6
6 6
6 6
6 6
6 6
FAXBACK +44 (0) 141 812 7820