Http Www.dgserve HPSV Fitt

download Http Www.dgserve HPSV Fitt

of 18

Transcript of Http Www.dgserve HPSV Fitt

  • 7/31/2019 Http Www.dgserve HPSV Fitt

    1/18

    15-NOV-1Download Date:Page 1 of 18

    Sub: Rate Contract for supply of HPSV Fittings & Accessories

    Validity: From 01-JAN-11 To 31-DEC-11 .

    Ref:(1) This Office Tender Enquiry No. HPSV Fitt./ES-7/RC-A1030000/1211/37Opened on 09-DEC-10.

    (2) Your Quotation No. RE/RC:HPSV FITT(T)/2010/880 And Dated

    09-DEC-10.

    Dear Sir,

    You are hereby informed that your above refered tender read with subsequent letters mentioned above for the Stores

    specified in the Schedules annexed has been accepted. This rate contract will be governed by the terms and conditions

    brought in the Form no. DGS&D 1001 available from dgs&d sales counter on payment of Rs. 50/- .The Rate Contract

    and the schedules annexed here to shall be the sole repository of this Rate Contract/Transaction.

    SCHEDULES ANNEXED

    1.Schedule "A" Description of stores,prices,duties/taxes.

    2.Schedule "B" special conditions of contract / Other information.

    3.Schedule "C" Information to DDOs about parallel rate contracts.

    4.Annexure - Technical Specification

    Yours Faithfully,

    ( )

    Assistant Director(S)/Section Officer/Dy.Director

    For and on behalf of the purchaser named in the Form DGS&D 1001.

    Government of India

    Directorate General of Supplies & Disposals

    Jeevan Tara Building, 5 Sansad Marg

    New Delhi-110001

    Tel Number 23360610/23360537

    Rate Contract no. HPSV Fitt./ES-7/RC-A1030000/1211/37/05807/1432

    Dated 03-JAN-11

    Rate Contract

    To,

    RAJ ELECTRICALS

    214, FUNCTIONAL INDUSTRIAL ESTATE, PATPARGANJ,

    DELHI,

  • 7/31/2019 Http Www.dgserve HPSV Fitt

    2/18

    15-NOV-1Download Date:Page 2 of 18

    COPY TO:

    1.The Chief Controller of Accounts,Department of commerce,New Delhi/

    COA Mumbai/COA Kolkata,COA Chennai.

    (Through authentication cell) This issues with the approval of competent authority.

    2.Deputy Director General of Supplies & Disposals,Chennai -10 copies each

    3.Deputy Director General of Supplies & Disposals,Kolkata -10 copies each4.Deputy Director General of Supplies & Disposals,Mumbai -10 copies each

    5.Deputy Director General (QA),Kolkata -10 copies each

    6.Deputy Director General (QA),Chennai -10 copies each

    7.Deputy Director General (QA),Mumbai -10 copies each

    8.Deputy Director General (QA),DGS&D -10 copies each

    9.Inspection Authority ADG(QA) DGS&D New Delhi - 110001.

    10.Quality assurance Officer Director (QA) Delhi Directorate/ Mumbai,Chennai/Kolkata.

    11.Concurrent Audit

    12.MIS Cell

    13.Ledger clerk

    14.O.L.Section15.All Direct Demanding Officers as per mailing list maintained by DGS&D.

    ( )

    Assistant Director (S) / Section Officer / Deputy Director

    FOR DIRECTOR GENERAL OF SUPPLIES & DISPOSALS

  • 7/31/2019 Http Www.dgserve HPSV Fitt

    3/18

    15-NOV-1Download Date:Page 3 of 18

    1.Rate Contract No.:-HPSV Fitt./ES-7/RC-A1030000/1211/37/05807/1432

    Dated 03-JAN-11 For the Supply of HPSV Fittings & Accessories

    2.Advance Rate Contract No.:-

    Dated

    3.(a) Name and Full Address of the Firm :-

    ---------------------------------------------------------------------------------------------------------------------------------------------

    Item Model Store Description Unit RateNo. No. (in

    Rs.)

    ---------------------------------------------------------------------------------------------------------------------------------------------

    Type: for 70 Watt Lamps

    Type: for 150 Watt Lamps

    Type: for 250 Watt Lamps

    26.45

    26.45

    26.45

    Spare Ignitors

    Spare Ignitors

    Spare Ignitors

    SCHEDULE - A

    NOS.

    NOS.

    NOS.

    13

    14

    15

    DELIGHT

    DELIGHT

    DELIGHT

    Rs.

    TWENTY-

    SIX AND

    PAISE

    FORTY-

    FIVE

    ONLY

    Rs.

    TWENTY-

    SIX AND

    PAISE

    FORTY-

    FIVE

    ONLY

    RAJ ELECTRICALS

    214, FUNCTIONAL INDUSTRIAL ESTATE,

    PATPARGANJ,

    DELHI,

    DELHI - 110092

    Tel. No. - 22143204/5/6

    Fax - 22160513

    Email - -

    (b) Name and Full Address of Manufacturer :-

    RAJ ELECTRICALS

    214, FUNCTIONAL INDUSTRIAL ESTATE,

    PATPARGANJ, DELHI

    110092

    (c) Brand: DELITE

    4.Validity of Rate Contract: 01-JAN-11 To 31-DEC-11

    5.Description of Item, Specification,Unit, Rate

  • 7/31/2019 Http Www.dgserve HPSV Fitt

    4/18

    15-NOV-1Download Date:Page 4 of 18

    Type: for 400 Watt Lamps

    Type: for 70 Watt Tubular Lamps

    Type: for 150 Watt Tubular Lamps

    Type: for 250 Watt Tubular Lamps

    Type: for 400 Watt Tubular Lamps

    26.45

    1469.79

    2420

    2648.25

    2888.72

    Spare Ignitors

    Street Light Fittings with

    IP-66 Protection

    Street Light Fittings with

    IP-66 Protection

    Street Light Fittings with

    IP-66 Protection

    Street Light Fittings with

    IP-66 Protection

    NOS.

    NOS.

    NOS.

    NOS.

    NOS.

    16

    17

    18

    19

    20

    DELIGHT

    DELIGHT

    DELIGHT

    DELIGHT

    DELIGHT

    Rs.

    TWENTY-

    SIX AND

    PAISE

    FORTY-

    FIVE

    ONLY

    Rs.TWENTY-

    SIX AND

    PAISE

    FORTY-

    FIVE

    ONLY

    Rs. ONE

    THOUSAN

    D FOUR

    HUNDREDSIXTY-

    NINE AND

    PAISE

    SEVENTY-

    NINE

    ONLY

    Rs. TWO

    THOUSAN

    D FOUR

    HUNDREDTWENTY

    ONLY

    Rs. TWO

    THOUSAN

    D SIX

    HUNDRED

    FORTY-

    EIGHT

    AND

    PAISETWENTY-

    FIVE

    ONLY

    Rs. TWO

    THOUSAN

    D EIGHT

    HUNDRED

    EIGHTY-

  • 7/31/2019 Http Www.dgserve HPSV Fitt

    5/18

  • 7/31/2019 Http Www.dgserve HPSV Fitt

    6/18

    15-NOV-1Download Date:Page 6 of 18

    ( )

    Asstt. Director (S) / Section Officer / Dy. Director

    For and behalf of the purchaser named in the Form DGS&D 1001.

    All the R/C particulars including prices in respect of individual R/Cs are available on DGS&D website which can be

    accessed by all.The DGS&D website is http://dgsnd.gov.in

    23-Packing & Specification :

    Supply order(s) in any other form placed on or after 01-10-2008 shall not be valid and shall not be acted upon by the

    contractor or any other concerned agencies.

    DDO shall download the supply order and send an ink signed copy to the concerned paying authority specified in the

    rate contract through Registered / speed post immediately after on-line placement of Supply Order(s).

    see annexure

  • 7/31/2019 Http Www.dgserve HPSV Fitt

    7/18

    15-NOV-1Download Date:Page 7 of 18

    SCHEDULE - B

    RC Specification:1 70 Watt HPSV Class IP-66 Street Light Fittings

    1.01 Over all Dimension of fitting (LXWXH)

    (Tolerance -5%)

    550mmX250mmX155mm

    1.02 Bare weight of fitting in Kg (Min) 3.520 Kg

    1.03 Type of gasket used and its specification Neoprene1.04 Total weight of fitting with fixture but without lamp 5.3 Kg.

    1.05 Whether detail dimensional drawing depicting all

    parts? and colour photograph available with tenderer Yes

    1.06 Indicate the pattern of punch marking on flange of

    ballast for unique identification of product.

    R1

    2 150 Watt HPSV Class IP-66 Street Light Fittings

    2.01 Over all Dimension of fitting (LXWXH)

    (Tolerance -5%)

    630mmX280mmX160mm

    2.02 Bare weight of fitting in Kg (Min) 4.630 Kg.

    2.03 Type of gasket used and its specification Neoprene

    2.04 Total weight of fitting with fixture but without lamp 7.32 Kg

    2.05 Whether detail dimensional drawing depicting all

    parts? and colour photograph available with tenderer

    Yes

    2.06 Indicate the pattern of punch marking on flange of

    ballast for unique identification of product.

    R1

    3 250 Watt HPSV Class IP-66 Street Light Fittings

    3.01 Over all Dimension of fitting (LXWXH)

    (Tolerance -5%)

    700mmX310mmX180mm3.02 Bare weight of fitting in Kg (Min) 5.340 Kg.

    3.03 Type of gasket used and its specification Neoprene

    3.04 Total weight of fitting with fixture but without lamp 9.25 Kg.

    3.05 Whether detail dimensional drawing depicting all

    parts? and colour photograph available with tenderer

    Yes

    3.06 Indicate the pattern of punch marking on flange of

    ballast for unique identification of product.

    R1

    4 400 Watt HPSV Class IP-66 Street Light Fittings

    4.01 Over all Dimension of fitting (LXWXH)(Tolerance -5%)

    700mmX315mmX190mm

    4.02 Bare weight of fitting in Kg (Min) 5.350 Kg.

    4.03 Type of gasket used and its specification Neoprene

    4.04 Total weight of fitting with fixture but without lamp 10.95 Kg.

    4.05 Whether detail dimensional drawing depicting all

    parts? and colour photograph available with tenderer

    Yes

    4.06 Indicate the pattern of punch marking on flange of

    ballast for unique identification of product.

  • 7/31/2019 Http Www.dgserve HPSV Fitt

    8/18

    15-NOV-1Download Date:Page 8 of 18

    R1

  • 7/31/2019 Http Www.dgserve HPSV Fitt

    9/18

    15-NOV-1Download Date:Page 9 of 18

    1

    2

    3

    4

    5

    6

    7

    8

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/03242/1430

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/04512/1431

    HPSV Fitt./ES-7/RC-A1030000/1211/37/05455/1442

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/05454/1444

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/NA071/1438

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/04739/1433

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/05761/1427

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/04681/1439

    03-JAN-11

    03-JAN-11

    03-JAN-11

    03-JAN-11

    03-JAN-11

    03-JAN-11

    03-JAN-11

    03-JAN-11

    INDUSTRIAL KALINGA

    LITON LIGHTING INDUSTRY

    TWINKLE LUNINAIRES PVT LTD

    TWINKLE INDUSTRIES

    LORD KRISHNA ELECTRONIC INDUSTRIES

    ELECTROCINE INDUSTRIES

    COMMANDER ELECTRICALS

    SATYA ENGINEERING WORKS PVT.

    LIMITED

    6/3&4,Katori Mill,Rajender NagarIndl.Area,G.T.Road

    K.No. 22/6/1, Peepal Wali Gali, Gali No.9, Samaypur

    Badli,

    C-59, Preet Vihar, Vikas Marg, Delhi

    C-59, Preet Vihar, Vikas Marg,

    23-24 KRISHAN KUNJ, LAXMI NAGAR,

    56/18, Site-IV, Indl Area, Sahibabad, Ghaziabad

    D-14, 15, 114 & 115, Shreenath Industrial Estate,S. No. 197, B/H Voltas,

    Dadra Check Post

    A-111, Mangol Puri Indl. Area,

    Phase-II,

    Sahibabad

    Delhi

    Delhi

    Delhi,

    DELHI

    Ghaziabad

    Dadra

    UTTAR PRADESH

    DELHI

    DELHI

    DELHI

    DELHI

    UTTAR PRADESH

    DADRA NAGAR HAVELI

    201007

    110042

    110092

    110092

    110092

    201010

    396230

    Sr.No. NAME & FULL ADDRESS OF FIRM R/C NO & DATE

    SCHEDULE - C

    List of Parallel Rate Contract For HPSV Fittings & Accessories

  • 7/31/2019 Http Www.dgserve HPSV Fitt

    10/18

    15-NOV-1Download Date:Page 10 of 18

    8

    9

    10

    11

    12

    13

    14

    15

    16

    17

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/04681/1439

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/04793/1440

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/05459/1436

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/04297/1446

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/05047/1441

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/04432/1443

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/05807/1432

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/05601/1445

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/05204/1437

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/05758/1428

    03-JAN-11

    03-JAN-11

    03-JAN-11

    03-JAN-11

    03-JAN-11

    03-JAN-11

    03-JAN-11

    03-JAN-11

    03-JAN-11

    03-JAN-11

    FLORIDA ELECTRICAL INDUSTRIES LTD.

    JAIN INDUSTRIAL LIGHTINGS CORP.

    ARUN ELECTRICALS

    SUNEET APROTECH (P) LTD.,

    ELTON ELECTRICALS PRIVATE LIMITED

    RAJ ELECTRICALS

    ATLAS INDUSTRIES

    MAMTA PRODUCTS

    LUXOLITE INDUSTRIES

    B-147, Maya Puri Industrial Area, Phase-1

    B-70/22, DSIDC Industrial Complex, Lawrence

    Road,

    1/5, Khandsa Road, Gurgaon-122001

    2094/1, Gali No. 17, Prem Nagar,

    1759, Modern Industrial Estate, Bahadurgarh,

    214, FUNCTIONAL INDUSTRIAL ESTATE,

    PATPARGANJ,

    71, S.S.I. Laghu Udyog Nagar, G.T. Karnal Road,

    D-26, DSIDC Shed, Jhilmil Colony, Shahdara

    A-2/25, Site-IV, Sahibabad Indl. Area, Distt.

    Ghaziabad, U.P.

    New Delhi

    New Delhi

    Delhi-110035

    Gurgaon

    New Delhi

    Bahadurgarh

    DELHI,

    Delhi,

    Delhi,

    DELHI

    DELHI

    DELHI

    HARYANA

    DELHI

    HARYANA

    DELHI

    DELHI

    DELHI

    110034

    110064

    110035

    122001

    110008

    124507

    110092

    110033

    110095

  • 7/31/2019 Http Www.dgserve HPSV Fitt

    11/18

    15-NOV-1Download Date:Page 11 of 18

    17

    18

    19

    20

    21

    22

    23

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/05758/1428

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/04782/1429

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/04842/1434

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/05460/1447

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/05461/1435

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/05680/1448

    HPSV Fitt./ES-7/RC-

    A1030000/1211/37/05796/1450

    03-JAN-11

    03-JAN-11

    03-JAN-11

    03-JAN-11

    03-JAN-11

    03-JAN-11

    03-JAN-11

    SINGHANIYA LITE & LUMINARIUES (P)

    LTD.

    KUKREJA ENGINEERS

    MODERN LIGHTING SYSTEMS

    KOHLI & COMPANY

    ULTRA LIGHTING LTD.

    TANEJA SALES CORPORATION

    12/4, Ist Floor, Subhash Nagar

    H-1201, D.S.I.D.C. Narela Industrial Area, Narela

    Unit No.64, Block B-70, Dr.

    Lohia Industrial Area,

    Lawrence Road,

    T-5, Okhla Indl. Area, Phase-II,

    A-83, G.T. Karnal Road, Industrial Area, Azadpur,

    A-83, G.T. Karnal Road, Industrial Area, Azadpur,

    GHAZIABAD

    New Delhi

    Delhi

    Delhi

    New Delhi

    Delhi,

    Delhi,

    UTTAR PRADESH

    DELHI

    DELHI

    DELHI

    DELHI

    DELHI

    DELHI

    201010

    110027

    110040

    110032

    110020

    110033

    110033

    NOTE:

    (1) Before placing supply order, DDOs are advised to check with DGS&D or on the website whether any further RCs

    have been awarded or amendments to Rate Contract have been issued.

    (2) All the R/C particulars including prices in respect of individual R/C's are available on DGS&D website,which can be

    accessed by all. The access code of DGS&D website is http://dgsnd.gov.in.

  • 7/31/2019 Http Www.dgserve HPSV Fitt

    12/18

    15-NOV-1Download Date:Page 12 of 18

    1. FITTINGS:

    The fittings where specified shall be ISI marked to IS: 10322 (Part 5/Sec

    3)-1987(Reaffirmed 2005) (Incorporating Amendment Nos. 1, 2, 3 & 4)

    ,IS:10322(Part5/Secl)-1985(Reaffirmed 2005)(Incorporating Amendment Nos. 1,& 2),IS

    13383 (Part 2) : 1992( Reaffirmed 2000 ) (Incorporating Amendment No. 1) (for

    photometric) as applicable and with the following additional requirements. Street

    Light Fittings shall have photometric efficiency of 65%. Connecting wire from

    control gear terminal block to lamp holder shall be of 1.1 KV grade, copper

    conductor XLPE insulated.

    2. BALLAST:-

    Ballast shall generally conform to IS : 6616-1982( Reaffirmed 2006) with the

    following variations:-

    a)At rated voltage power delivered shall not be less than 92.5% and

    not more than 107.5% of the power delivered by the reference ballast.

    b)Between 92% and 106% rated voltage, the short circuit current shall be within

    limits given in IS : 9974 (Part I)-1981(Reaffirmed 2002) (Incorporating Amendment

    Nos. 1, 2, 3 & 4)under the heading ballast design information.

    c)Abnormal operation (type test)is to be carried out in association with

    ignitor

    and as per ignitor specification and for each ratings.( Firm shall declare the

    model

    and manufacturer of ignitor for which their ballast is suitable)

    d)High voltage test of 5 KV for one minute as a type test and 5 KV for 5

    seconds as an acceptance test.

    NOTE: Firm shall have to use their own make ballst for manufacturing of HPSV

    fittings

    3.IGNITOR:

    I. Performance requirements between 92% & 106% of rated voltage.

    (a)Pulse height,

    (i) 1.8 KV to 2.3 KV-70W HPSV fitting

    (ii) 2.8 KV to 4.5 KV-150W & above HPSV fittings.

    (b)Direction & postion not material for the time being .

    (c)Rise time 2 micro. secs. ( Maximum)

    (d)Duration 0.9 to 8 micro. sec.

    (e)Pulse repetition rate: 1 per cycle ref IS: 9974.

    (f)Subsequent pulse height less than 70%.

    II. Ignitor shall not pulsate after the lamp has been fully ignited i.e.current

    though it shall be steady.III. Ignitors wrongly connected shall have not deliterious(adverse)effect on the

    luminaire.

    I.TYPE TESTING:.

    A. FOR FITTINGS:- Additional requirements of type tests.

    a) Temp. rise and voltage increase as per Clause IS : 9974 (Part I)-1981

    (Reaffirmed 2002) (Incorporating Amendment Nos. 1, 2, 3 & 4).IS:9974 pt-II

    should also be referred as applicable.

    b) High voltage test of 5 KV for 1 Min with all terminals shorted and

    ANNEXURE

  • 7/31/2019 Http Www.dgserve HPSV Fitt

    13/18

    15-NOV-1Download Date:Page 13 of 18

    capacitor

    removed between terminal wire and earthing.

    c) High Voltage test of 5 KV for1 Min. between two terminals of lamp and lamp

    cap

    (on lamp holders).

    B. FOR BALLAST.

    As per IS : 6616-1982( Reaffirmed 2006 ) and specification for ballast with

    following additional requirements.

    a) Abnormal operation(Type Test)is to be carried out in association with

    ignitor and as per ignitors specification and for each rating. Firm shall declare

    the model and manufacturer of ignitor for which their ballast is suitable.

    b) High Voltage test of 5 KV for one Min. as a type test.

    C. FOR IGNITORS.

    i) Protection against accidental contact. The tests shall be conducted with

    ballasts of makes offered by the firm in the luminaires/as spares.

    ii) Moisture resistance, insulation resistance and electric strength (5KV for 1

    Min.)The test will be conducted in accordance of IS : 6616 - 1982( Reaffirmed 2006

    )

    iii) Fault condition.

    When starting device is operated under fault condition like shorting of

    its terminal of lamp terminals, there shall be no emission of flame etc.& no

    accessible

    part will become live.

    iv) HEATING TEST;

    Heat test under normal conditions of operation with lamp at rated voltage

    &

    in abnormal condition without lamp at 110% voltage the components shall not

    exceed

    the permissible limits of operating temp. After these test and cooling down, the

    ignitor shall operate normally.

    v) Performance test for pulse characteristics.

    Pulse characteristic measured with an appropriate osciloscope with ballast

    & length of wire as provided by the manufacturer in the fitting upto the lamp

    terminals.

    vi) Creepage distance.

    Test will be conducted in accordance of IS : 6616-1982( Reaffirmed 2001 ).

    vii) Endurance

    In this test two ignitors are connected as in normal use associated with an

    appropriate ballast.The test voltage shall correspond to 1.06 x the rated supply

    voltage of the ballast. The ignitors are operated in conformity with their

    marking at the maximum allowable temp. in the fittings and without lamp.

    In doing so the connections of one of ignitors are loaded by the maximum

    allowable load capacitance say 1000 or unless otherwise specified while the

    connections of the other ignitors are left unloaded.After 30 days of continuous

    test they shall meet the requirement and ignite the lamp.

    ACCEPTANCE TEST:

    A FOR FITTING:-

    a. High voltage test of 2.5KV for one minute with all terminals shorted and

    capacitors removed between terminals wire and earthing. High Voltage of 2.5 KV

    for one minute between two terminals of lamp cap ( on lamp holders).

  • 7/31/2019 Http Www.dgserve HPSV Fitt

    14/18

    15-NOV-1Download Date:Page 14 of 18

    b. Acceptance test as per governing specification.

    B. FOR BALLAST.

    In addition to tests referred in the specification the following tests are to be

    conducted.

    a. Performance test with lamp, ignitor and ballast.

    b. Watt loss and cold resistance on random samples drawn as per sampling plan for

    acceptance tests specified in in IS:6616 .however Sample size would be double of

    that specified in IS:6616. The value of watt loss at nominal rated current

    circulating directly and measured by a watt meter of 0.2 pf at an ambient

    Temperature of 27 degree C shall conform to the following:

    i) Watt loss shall not exceed the figures as under:-

    For 70 Watts Lamp ballast - 15 Watts maximum

    For 150 Watts Lamp ballast - 19 Watts maximum

    For 250 Watts Lamp ballast - 26 Watts maximum

    For 400 Watts Lamp ballast - 38 Watts maximum

    ii) Resistance tolerance + 5% to -10% (Tenderers to declare the nominal cold

    resistance value of winding in their offer).

    iii) For energy efficient ballasts samples size for acceptance tests shall be

    double the number of samples as indicated in IS:6616 and tests for limitation of

    ballast heating will be conducted an acceptance test on each lot, each ballast

    will be marked with watt loss and S.No. of the ballast.

    C) FOR IGNITORS.

    i) To be carried out on 4 samples out of every lot of 1000 Nos. and all sample

    shall pass.

    ii) Measurement of pulse height, duration, rise time, pulse rate etc. with the

    ballast offered.

    iii)High voltage test at 5 KV for 5 seconds.

    D) Condensor shall conform to IS : 1569 /1976 (Reaffirmed 2001) (Incorporating

    Amendment No. 1) and shall be suitable to give a power factor of 0.85 (minimum)

    E) Lamp holders shall conform to IS: 10276 / 1982(Part I & II) (Reaffirmed 2003).

    1. Suppliers shall furnish complete and satisfactory type test certificate as per

    T/E specification for each item to the concerned DQA at the time of registration &

    inspection.TTC shall be from any Government laboratory.

    2. Lamps shall not be the part of supply.

    QA PROCEDURE:

    The following procedure are incorporated to augment the inspection process:

    1. The firms shall furnish detailed drawing along with bill of material of each

    rating/ variety of HPSV fittings for which they have been awarded DGS&D rate

    contract. These drawings should also indicate average weight of the fittings (with

    manufacturing tolerance) and should be in consonance with drawings/ sketches

    vetted by Lab at the time of type testing .

    2. Firms shall declare the source of aluminum die cast body, toughened glass,

    aluminum reflector and neoprene rubber gasket and make/ model/ rating of bought

    out electrical components being used in manufacturing/assembly of HPSV fittings.

    They should also maintain record and proof of periodical testing of critical

  • 7/31/2019 Http Www.dgserve HPSV Fitt

    15/18

    15-NOV-1Download Date:Page 15 of 18

    components. .

    3. Firms shall also declare the weight of the finished copper wound ballast,

    weight of the stamping and its type/ grade, size of winding wire, weight of copper

    winding wire and cold resistance of winding wire at 20 degree C (all with

    tolerances) for each rating of HPSV ballast. Value of resistance may be converted

    as per engineering practice at any required temprature.

    4. For re-traceability purpose unique identification mark of the firm and serial

    number/ lot number shall also be punched on the flange of ballast. In case a firm

    prefers to punch the lot number, the same should not be repeated for the lot

    offered for next inspection/ future.

    5. Firms shall also keep QA office informed as to when die cast bodies are

    received by them and ready for painting so that QA officer may be able to verify

    the process on periodical basis and ensure the quality of casting as per

    specification.

    6. Dimension of fitting shall be as per indicative value given in specification

    of TP. .Fresh TTC is not required for mere change in dimension / size if

    fittings being tendered/offered are having greater size in comparison to

    sizes indicated in sketch of type tested products of different ratings which has

    been authenticated by lab. How ever if sizes of type tested fittings are more

    than required value , firms have to offer products accordingly and they are not

    allowed to reduce sizes.

    7. During inspection the QA officers shall also verify the offered stores for

    their conformance with the declaration made by the firm.

    The overall dimensions (LxWxH) & weight of the fittings, weight and cold

    resistance of ballast winding at 20 0C, punched unique identification mark of the

    firm & lot number and serial numbers of ballasts shall be recorded in the I/notes

    for the guidance of the consignees with the explicit remark that the stores may be

    checked for these parameters and deviations if any should be reported for

    appropriate corrective and preventive action .

    8. Samples of items tested out of the lot offered for first inspection are to be

    retained by firm with detailed identification ( R/C no, rating, date of

    inspection, TTC no etc) for comparison during subsequent inspection. Retention

    period of sample should not be less than 24 months since dispatch of last

    consignment to user against this R/C.

    Spare Ignitors

    Street Light Fittings with IP-66 Protection

    Specification :

    Spare Ignitors for luminaires against schedule -66 i.e. IP-66

    class (make & type) to be specified and to be supported with test reports. Also

    refer to GTR

    Specification :

    Street Light Luminaires, IP-66 Class ISI marked to IS : 10322

  • 7/31/2019 Http Www.dgserve HPSV Fitt

    16/18

  • 7/31/2019 Http Www.dgserve HPSV Fitt

    17/18

    15-NOV-1Download Date:Page 17 of 18

    of

    IS 10322 ( Part I ) : 1982( Reaffirmed 2005 ). Fittings shall have photometric

    efficiency of 65%.

    vii.) Dimension of fittings i.e. Length x Width x Height for respective rating

    should be as under with maximum permissible minus tollerace on dimension of 5%:

    70 Watt: 550x250x150

    150 Watt: 630x280x160

    250 Watt: 690x310x180

    400 Watt: 700x315x190

    All dimension are in mm and without any restriction on upper limit on dimension.

    It may be noted that above dimensions are given for homogenity however once

    dimension declared by firm as per their manufacturing drawing allowable

    manufacturing tollerance in negative side shall not be more than 5mm which may

    arise due to shrinkage etc.

    Drawing/Proforma/Annexure Attached [Click on the following to View/Print ]

    Inspection Report Performa

    https://www.dgserver.dgsnd.gov.in/IR_HPSVFITTING.pdfhttps://www.dgserver.dgsnd.gov.in/IR_HPSVFITTING.pdf
  • 7/31/2019 Http Www.dgserve HPSV Fitt

    18/18

    LIST OF ALL AMENDMENTS

    For RC No. HPSV Fitt./ES-7/RC-A1030000/1211/37/05807/1432

    Sr No. Amendment No. Amendment

    Date

    Effective

    From

    HPSV Fitt./ES-7/RC-A1030000/1211/37/05807/1432/343611 04-JAN-11 03-JAN-11

    Amendment In

    Amendment in E

    Duty,Annexure &

    Clauses

    http://www.dgserver.dgsnd.gov.in/formseal/server/custompdfsigner.jsp?TID=HPSV%20Fitt./ES-7/RC-A1030000/1211/37/05807/1432/34361/04-JAN-11&FORMNAME=RCAMEND&URL=/reports/rwservlet?KEY1&report=rcamendAPPROVpdf.rdf&destype=cache&desformat=pdf&PRCNO=HPSV%20Fitt./ES-7/RC-A1030000/1211/37/05807/1432&LETNO=nil&PFILE=04A10300001211&DKDATE=04-01-2011&LETDATE=http://www.dgserver.dgsnd.gov.in/formseal/server/custompdfsigner.jsp?TID=HPSV%20Fitt./ES-7/RC-A1030000/1211/37/05807/1432/34361/04-JAN-11&FORMNAME=RCAMEND&URL=/reports/rwservlet?KEY1&report=rcamendAPPROVpdf.rdf&destype=cache&desformat=pdf&PRCNO=HPSV%20Fitt./ES-7/RC-A1030000/1211/37/05807/1432&LETNO=nil&PFILE=04A10300001211&DKDATE=04-01-2011&LETDATE=