USTA_Guia_5_Ensayo de Deflexion en Vigas HST 1_12 marco HST 1 (mm_N)_expositores.pdf
HST 721 Mouse Lab: Noninvasive Assessment of Cochlear...
Transcript of HST 721 Mouse Lab: Noninvasive Assessment of Cochlear...
![Page 1: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/1.jpg)
1
HST 721 Mouse Lab:Noninvasive Assessment of Cochlear Function
![Page 2: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/2.jpg)
2
DPOAEs
ABRs
Flowchart of the cochlear signal generationDPOAEs assess all structures except IHCs and NeuronsABRs assess all structures
ABRs vs. DPOAEs
![Page 3: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/3.jpg)
3
DPOAEs:Distortion Product Otoacoustic Emissions
![Page 4: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/4.jpg)
4
INP
UT
OUTPUT
DPOAEs: Source of the Nonlinearity
![Page 5: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/5.jpg)
5
Cochlear Location BaseApex
f1
Cochlear Location BaseApex
f1 f2
Cochlear Location BaseApex
f1 f2
2f1-f2
Cochlear Location BaseApex
f1
f22f1-f2
DPOAEs: Place of cochlear generation
![Page 6: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/6.jpg)
6
QuickTime™ and a YUV420 codec decompressor are needed to see this picture.
DPOAEs: Source of Amplification
![Page 7: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/7.jpg)
7
DPOAEs: How they are measured in humans
![Page 8: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/8.jpg)
8
DPOAEs: How they are measured in the lab
![Page 9: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/9.jpg)
9
DPOAEs: How they are measured in the lab
![Page 10: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/10.jpg)
10
DPOAEs: What you will see in mice
-20
-30
-10
0
10
20
30
30
10 20 30 40 50 60 70 80 90
Primary Tone Level (dB SPL)
Noise Floor
DP amplitude vs. level functions in 3 ears1 pair of primaries at many SPLs
Ear-canal spectrum for 1 pairof primaries at 1 SPL
f2f1
2f1-f2
Noise Floor
“Threshold”
![Page 11: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/11.jpg)
11
DPOAEs: What you can compute in mice
DP iso-response functions“Threshold” vs frequency
![Page 12: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/12.jpg)
12
DPOAEs: Assess OHCs and all “upstream elements”
![Page 13: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/13.jpg)
13
ABRs:Auditory Brainstem Responses
![Page 14: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/14.jpg)
1414
Click Stimulus
Single-Fiber
Responses
Compound Action
Potential (CAP)
CAPs: Dominated by auditory nerve response
![Page 15: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/15.jpg)
1515
ABRs: Include potentials from several brainstem nuclei
-
Middle Ear
AuditoryMid-Brain &Brainstem
Auditory Cortex
Inner Ear
Click Stimulus
Auditory Brainstem
Response (ABR)
![Page 16: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/16.jpg)
1616
ABRs: Which cells dominate the peaks ?
-
Middle Ear
AuditoryMid-Brain &Brainstem
Auditory Cortex
Inner Ear
VCN
SOC
![Page 17: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/17.jpg)
1717
ABRs: Tone pips vs. Clicks
![Page 18: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/18.jpg)
1818
Single-Fiber Recordings
ABRs: Frequency selectivity of tone pips
![Page 19: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/19.jpg)
1919
ABRs: Tone pips vs. Clicks
![Page 20: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/20.jpg)
2020
ABRs: Signal Averaging
Noise decreases in proportion to √n,
where n = # averages
Near threshold, 1024 averages are typically
acquired for ABR.
![Page 21: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/21.jpg)
2121
Response amplitude grows with increasing
stimulus SPL
ABRs: What is Threshold?
![Page 22: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/22.jpg)
2222
ABRs: What is Threshold?
Noise floor, and therefore “threshold” is affected by amount
of averaging
Strategy 1:Iso-response criteria
![Page 23: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/23.jpg)
2323
ABRs: What is Threshold?
Noise floor, and therefore “threshold” is affected by amount
of averaging
Strategy 2:Follow the waves
80 1 2 3 4 5 6 7
Normalized Waveforms
Time (msec)
10 dB
15 dB
20 dB
25 dB
30 dB
35 dB
40 dB
45 dB
50 dB
55 dB
60 dB
65 dB
70 dB
75 dB
Threshold
![Page 24: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/24.jpg)
2424
ABRs: What is Threshold?
Even with extensive averaging, ABR/CAP
“Threshold” is > single fiber “Threshold”
![Page 25: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/25.jpg)
2525
ABRs: Signal Averaging
“Artifact Reject” in the software allows
removal of large potentials due to EKG
![Page 26: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/26.jpg)
26
ABRs: How they are measured in the lab
![Page 27: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/27.jpg)
2727
ABRs: How they are measured in the lab
![Page 28: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/28.jpg)
2828
ABRs and DPOAEs:The Laboratory
![Page 29: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/29.jpg)
2929
Ear Canal Surgery
![Page 30: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/30.jpg)
3030
LabVIEW Software Controller: Main Menu
3
Group ID #
ABR ACQUISITION ABR DATA PLOT
EQPT SETUP
QUIT
NEW GROUP
RUN OPTIONS
DP ACQUISITION0
DP RUN #DP DATA PLOT
SETUP OPTIONS(do each only once)
0
ABR RUN #
![Page 31: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/31.jpg)
3131
Software Controller: DPOAE Control & Indicators
4.0
f2 Frequency
15
Start dB
80
Stop dB
5
dB Step
25
#Waves per Spectrum
1. Set Stimuli
2. S tart START
3. Watch Data Acquisition
ABORT
4. Add Notes (Optional)
5. Sav e SAVE DATA
6. Note FilePath
7. Return to Main Menu RETURN
Type stuff here if you want
0
-140
-120
-100
-80
-60
-40
-20
Frequency (Hz)
500001000 10000
Response Spectrum
2
ID #
1
Run #
90
-40
-30
-20
-10
0
10
20
30
50
60
80
Primary Level (dB SPL)
805 10 15 20 25 30 35 40 45 50 55 60 65 70 75
DPOAE Amplitude vs Level
f1
105.46103.25 MAX SPL
f1 f2
1.2513
-1.2199-1.0000
-0.5000
0.0000
0.5000
1.0000
Time (msec)
2.00.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8
Response Waveform
C:\Data\HST721- DATA\HST721-2\DP-2-1
2f1-f2
40
70
f1
f2
2f1-f2
Noise Flr
![Page 32: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/32.jpg)
3232
Software Controller: Data Storage
:RUN-1 DP I-O 3:54 PM:Level Step (dB):5 Start dB: 20 Stop dB: 50# Buffers Averaged: 25Sampling Interval:4 Ear:Right
:NOTES-:CHAMBER-4
:ANALYZED DATA:Command dB Measured f1(dB) Measured f2(dB) 2f1-f2(dB) 2f1-f2Nse(dB)20.00 30.01 19.97 -24.01 -25.3325.00 35.05 24.98 -26.75 -23.7130.00 40.04 30.01 -25.80 -25.4235.00 45.04 35.01 -25.51 -24.8640.00 50.04 40.04 -22.93 -25.0645.00 55.11 45.05 -20.88 -24.5450.00 60.10 50.05 -23.63 -24.94
:RAW WAVEFORMS0.002390 0.003187 0.004161 0.006183 0.009836 0.016199 0.0277110.002397 0.003308 0.004397 0.006392 0.010246 0.016801 0.0288280.002385 0.003362 0.004509 0.006510 0.010535 0.017273 0.029696
etc.
![Page 33: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/33.jpg)
3333
Software Controller: ABR Control & Indicators
START
ABORT
10
START (dB)
80
STOP (dB)
512
# AVERAGES per LEVEL
8.00
FREQUENCY
5
dB STEP
Tone Pip Stimuli
SAVE DATA
35
REP RATE (pips/sec)
15
REJECT THRESH (µV)
2. Start
1. Set Stimuli
5. Save
3. Watch Data Acquisition
4. Add Notes (Optional)
6. Note FilePath:
RETURN7. Return to Main 3
ID #
15
0
5
10
1000 20 40 60 80
Amplitude vs Level
20
-1
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
80 1 2 3 4 5 6 7
1
RUN #
10
8
9
Time (msec)
90 1 2 3 4 5 6 7 8
Current Average
113 MAX SPL
6 # RejectsReject Flag
512 # Averages
80SPL
6
-6
-4
-2
0
2
4
Time (msec)
600 5 10 15 20 25 30 35 40 45 50 55
Stimulus Waveform
Level (dB SPL
C:\Data\HST721- DATA\HST721-3\ABR-3-1
Stacked Waveforms - All Levels
SPLList
![Page 34: HST 721 Mouse Lab: Noninvasive Assessment of Cochlear Functionweb.mit.edu/HST.721/www/Lectures/Lecture_OAEABR.pdf · DPOAEs: How they are measured in the lab. 10 DPOAEs: What you](https://reader033.fdocuments.in/reader033/viewer/2022051919/600bb37880323a436c7588ad/html5/thumbnails/34.jpg)
3434
Software Controller: Data Storage
:RUN-0 ABR I-O 10/24/2003 4:47 PM: EAR: R FREQ: 16.00 # AVES: 400 REP RATE (/sec): 80 SAMPLING (µsec): 10:NOTES-:CHAMBER-4:SPLs TESTED-20;30;40;50;60;70;80;
:ANALYZED DATA:SPL "NEURAL" P-P "CM" P-P20.000 1.563 1.29630.000 1.587 1.52940.000 1.514 1.01750.000 1.562 1.56660.000 1.820 1.49070.000 2.368 2.67180.000 3.563 4.549
:RAW WAVEFORMS-0.084572 -0.060116 -0.104443 0.059216 0.167206 -0.009075 -0.132732-0.046043 -0.051418 -0.105358 0.054485 0.158127 -0.014187 -0.088329-0.042152 -0.030743 -0.097805 0.046932 0.125854 -0.006329 -0.072536