    Type:- Continuous Annealing Pickling Line.

    Line Direction: - Left to Right (viewing from operator side)

    Material: - HOT ROLLED COILStainless Steel Strip,

    Strip width: - 850 mm (min.) 1,560 mm (max.)

    Strip thickness: - 2.0 - 7.0 mm

    Coil weight: - 28,000 kg max. Exclusive sleeve and interleaving

    Coil ID: - ID - 660 mm

    Coil OD: - OD - 2200 mm max

    Basic Technical Data

  • 7/28/2019 HRAP PRESENTAION

    4/20

    Entry Coil Storage Saddle :-

    Capacity : 28,000 kg

    Coil OD : 2200 mm max / 850 mm min

    Entry Coil Car :- Lift capacity 28,000 kg

    Uncoiler 1 :-

    Coil ID : 660 mm

    Coil OD : 1850 mm (max.)

    Expand diameter : 760 mm

    Collapse diameter : 608 mm

    Uncoiler 2 : -Coil ID : 660 mm

    Coil OD : 1850 mm (max.)

    Expand diameter : 760 mm

    Collapse diameter : 608 mm

    Entry Section Specification

  • 7/28/2019 HRAP PRESENTAION

    5/20

    This welding process is a MIG welding. An endless wire is fed

    through a torch with 100 % Argon (shielding) gas supply. The

    wire movement is motorized. Inert gas is chemically neutral, no

    reaction with the molten metal. Active gas is an inert gas with an

    addition of an active gas (i.e. 3 % oxygen ), this reacts with the

    metal and heats up the weld.

    Welder Unit comprising of:-

    1. Shearing Operation2. Welding Operation

    3. Notching Operation

    Oxytechnik Welding

  • 7/28/2019 HRAP PRESENTAION

    6/20

    Parameters:-

    Feed wire rate:- 1150 ~1170 rpm

    Welding Current :- 220~240 amp

    Argon flow rate :- 15 m3/hrWelding Carriage speed :- 2-5 mpm

    Precautions:-

    While working on shear or handling scrap pieces, use hand

    glovesDont put hands below the shear while cutting

    Dont see welding light with naked eye

    Welding Parameters & Precautions

  • 7/28/2019 HRAP PRESENTAION

    7/20

    This is an arrangement used for accumulatingthe strip for uninterrupted operations of the

    process while joining the two coil ends together inorder to make the strip continuous.

    The storage capacity is 200 mtrs.

    Entry Horizontal Accumulator

  • 7/28/2019 HRAP PRESENTAION

    8/20

    Overall dimension.

    Total length from entry -seal to exit seal roll 72.510 mtrs Length of furnace no 1. 14.600 mtrs Length of furnace no 2 14.600 mtrs

    Length of furnace no 3. 18.760 mtrs Length of furnace no 4. 18.760 mtrs Width inside furnace No 1 & 2. 3.438 mtrs Width inside furnace No 3 & 4. 2.638 mtrs

    Furnace section

    Zone temperature and strip temperature Burner operation (switch over) Furnace roll condition Catenary position Excess Oxygen (periodically) Gas leaks

    Follow proper procedures for lighting up and shutting down

    FURNACE TECHNICAL

    SPECIFICATION

  • 7/28/2019 HRAP PRESENTAION

    9/20

    Furnace Parameters

    NO OFFURNACE

    NO OFHEATINGZONES

    NO OFBURNERS EACHZONES

    TYPE OF BURNERS TOTAL NOOF PILOTBURNERS

    NO OFREGENRATIVEBOX

    F#1

    F#2 3 14 Nos EJ 18 Burner06 Nos60/80 Burner08 Nos

    14 Nos 14 Nos

    F#3 318 Nos 30/40 Burner18 Nos 18 Nos 18 Nos

    F#4 3 16 Nos 30/40 Burners06Nos20Therm05 Nos

    15 Therm -05 Nos

    06 Nos 06 nos

  • 7/28/2019 HRAP PRESENTAION

    10/20

    Zone 4

    inCZone 5

    inCZone 6

    inCZone 7

    inCZone 8

    inCZone 9

    inCZone 10

    inCZone 11

    inCZone 12

    inC

    1000 1000 1030 1060 1100 1120 1120 1120 1100

    FURNACE TEMPERATURE

  • 7/28/2019 HRAP PRESENTAION

    11/20

    QUENCHING SECTION & Dryer

    Air Quenching Air & WaterQuenching

    Water Quenching

    Dryer

  • 7/28/2019 HRAP PRESENTAION

    12/20

    Shot blast Specification:No. of wheels 4 /Chamber

    No. of wheels on top 2 /Chamber

    No. off wheel on bottom 2 /Chamber

    Shot Blasting Chamber 3

    Elevator 2 /Chamber

    Dust Collector Shaker type

    No. of shaker 2

    No. of filter 132

    Steel Shots used S-110

    Shot Blasting Section

  • 7/28/2019 HRAP PRESENTAION

    13/20

    Mixed Acid Pickling Tanks 1, 2, 3, 4 & 5Tank capacity : 65 m each

    Pickling Section

    Acid Bath Parameter Aim Range

    HNO3 Concentration 135g/l (13.5%) 120-145g/l (12-14.5%)

    HF Concentration 36g/l (3.6%) 32-40 (3.2-4%)

    Temperature (0C) 60 55-65

    Metals (g/l) 25 25-30

    Re-circulation Flow (m3/hr) 2 x 200 -

    Re-circulation Pressure (bar) 2

    Tank Turbulence 100% 100%

  • 7/28/2019 HRAP PRESENTAION

    14/20

    HNO3 penetrates the cracks/pores in the oxide

    Pickling Reactions

    + + + + + + + + + + + + + + + +

    + +++

    +

    +

    +

    +

    The chemical dissolution of thechromium depleted zone ceases whenthe concentration of Fe3+ is high

    enough

    2 Fe + 3 NO3- + 6 H+ 2 Fe3+ + 3 NO2

    - + 3 H2O

    Only nitric acid (HNO3) is operating

  • 7/28/2019 HRAP PRESENTAION

    15/20

    Pickling

    + + + + + + + + + + + + + + + + + + + + + + +

    ##

    #

    #

    #

    ##

    ##

    ##

    ##

    #

    ##

    #

    ##

    The positive iron ions (+) reacts with hydro

    fluoric acid forming complex ions (#) allowing

    HNO3 to continue dissolving the chromium

    depleted zone. The nitrous fume contributes to

    the scale breaking.

    Both HNO3 and HF are operating!!!

    Fe3+ + 2 HF FeF2+ + 2H+

    Fe3+ + 3HF FeF3 + 3H+

    2 NO2- + 2H+ NO + NO2 + H2O

    Clean surface

  • 7/28/2019 HRAP PRESENTAION

    16/20

    High Pressure Rinse

    One pump on duty, one pump on standby

    Flow rate 270 l/min

    4 spray bars on duty (2 top, 2 bottom) and 4 spray bars on standby

    Water pressure 95-110 bar

    Water temperature ambient

    Contamination non- recirculating system

    Low Pressure Rinse ( Hot Condition)

    Flow rate 25m3/hr Water pressure 2 bar

    Tempreture - 50 60 0C

    Brushes 16 to 20 amps

    Rinsing Section

  • 7/28/2019 HRAP PRESENTAION

    17/20

    Exit AccumulatorThe storage capacity is for 180 mtrs.

    Recoiler

    Coil ID : 660 mm

    Maximum coil OD : 1850 mm

    Maximum coil weight : 22000 kg.

    Nominal dia. : 660 mm

    Exit Coil CarExit Coil Storage Saddle with coil weighing system

    EXIT SECTION

  • 7/28/2019 HRAP PRESENTAION

    18/20

    LINE SPEED

    Thickness (mm) Speed (m/min)

    1025 & 1275 mm wide 1525 mm wide

    2.5 30 24.6

    3 30 24.6

    3.5 28 24.6

    4 24.6 23.9

    4.5 21.8 21.4

    5 19.6 19.2

  • 7/28/2019 HRAP PRESENTAION

    19/20

    Tension Unit Factors:-Uncoiler - 0.3 -0.5 kg/Cm

    Entry Accumulator - 0.8 -1.0 kg/Cm

    Furnace - 0.5 -0.8 kg/Cm

    Shot Blast - 0.8 -1.0 kg/Cm Pickling - 0.3 0.5 kg/Cm

    Exit Accumulator - 1.5 1.8 kg/Cm

    Recoiler - 2.5 - 3.0 kg/Cm

    Formula For Calculating Tension:-

    Width thickness unit factor = Tension

    Tension Parameters

  • 7/28/2019 HRAP PRESENTAION

    20/20

    Thank You