5-1
5.1 General The FA-100 uses five CPUs which run with an individual program.
Table 5.1.1 Program
Note) See the Table 5.1.2 on page 5-2. Procedure Figure 5.1.1 shows the outline of the program updating.
CPU Program No. Handling 245-0001-001-0x For old MPB boardnote) MAIN CPU U1 245-0001-002-0x For new MPB board note) TDMA signal
245-0002-001-0x For old MPB board note) SUB CPU U11 245-0002-002-0x For new MPB board note) Display, keyboard and serial data
H8S1 CPU U20 245-0003-001-0x Data to/from SNSR ports H8S2 CPU U21 245-0004-001-0x Data to/from EXTRA-1, BEACON and LR ports H8S3 CPU U22 245-0005-001-0x DSC reception
Chapter 5. Updating program
Fig. 5.1.1 Outline of program updating
Clearing memory after Main and Sub CPU program updating !!
![Page 2: How to Update FA100 Program](https://reader036.fdocuments.in/reader036/viewer/2022081721/551e4b3c4a795982108b4ad3/html5/thumbnails/2.jpg)
5.1 General
5-2
Every program is updated asynchronously in no flow control at 9600 bps. It is unnecessary to set the SET I/O PORT of [MENU][6][1]. 1. Confirming the program version Pressing [MENU][7] and [1], shows the list of the program number and version. Press [CLR], shows the program version in detail.
[PROGRAM NO.] [PROGRAM NO.]
MAIN : 245-0001-00x MAIN : 245-0001-00x0x SUB : 245-0002-00x SUB : 245-0002-00x0x H8S1 : 245-0003-001 H8S1 : 245-0003-0010x H8S2 : 245-0004-001 H8S2 : 245-0004-0010x H8S3 : 245-0005-001 H8S3 : 245-0005-0010x
When the program number differs from one in the above list, update the program again with the correct selection of the Loader File. Note: Program number of MAIN and SUB CPUs There are two types of MPB board (24P0015): old type (24P0015-55 and before) and new type (24P0015-66 and after). These boards are loaded with different MAIN- and SUB-CPU programs. Use MPB board (hardware) and software in correct combination. Before servicing, verify the program number.
Table 5.1.2 Program files
MAIN and SUB CPU program numbers MAIN: 245-0001-001
SUB: 245-0002-001 MAIN: 245-0001-002 SUB: 245-0002-002
Old MPB board (24P0015-55 and before) Possible Not possible
New MPB board (24P0015-66 and after)
Possible by changing jumpers JP6: Cut JP’: Short
Possible JP6: Short JP7: Open
JP6 JP7
[CLR]
Fig. 5.1.2 Jumper-6 and 7 position in MPB board : 24P0015-66
![Page 3: How to Update FA100 Program](https://reader036.fdocuments.in/reader036/viewer/2022081721/551e4b3c4a795982108b4ad3/html5/thumbnails/3.jpg)
5.1 General
5-3
2. Clearing memory after updating See page 8-14 for “Factory reset”. (Turn on the unit while holding [CLR]. Release the hand when “COMPLETE” appears.) After clearing the memory, reset “INTI SETTING” and “SYSTEM SETTING”.
3. Checking “ROM/RAM” after updating See page 8-8 for “MEMORY TEST”. (Press [MENU][7] and [2] to confirm the ROM/RAM TEST result.) ROM/RAM test must be OK.
[MEMORY TEST] ROM RAM MAIN : OK OK SUB : OK OK H8S1 : OK OK H8S2 : OK OK H8S3 : OK OK
Fig 5.1.3 MEMORY TEST display
4. When BACK UP error is displayed When BACK UP error message appears after updating SUB CPU program, INIT SETTING in [MENU][5] and SYSTEM SETTING in [MENU][6] must be carried out.
[ERROR] BACKUP ERROR ! ESC :[ENT] Significant change of SUB CPU program will come above in convenience.
![Page 4: How to Update FA100 Program](https://reader036.fdocuments.in/reader036/viewer/2022081721/551e4b3c4a795982108b4ad3/html5/thumbnails/4.jpg)
5.2 Program files
5-4
5.2 Program files Each program disk contains following files. The file size varies depends on the version level.
Table 5.2.1 Program files
CPU File
MAIN (245-0001-00x0x)
SUB (245-0002-00x0x)
H8S1 (245-0003-00010x)
H8S2 (245-004-0010x)
H8S3 (245-005-0010x)
Him.bin (89kB) X X
Upw.exe (449kB) X X
Himmain.mot (669kB) X
Himsub.mot (773kB) X
ComHost.exe (446kB) X X X
Loader.bin (2kB) X X X
H8s1.bin (24kB) X
H8s2.bin (25kB) X
H8s3.bin (52kB) X
![Page 5: How to Update FA100 Program](https://reader036.fdocuments.in/reader036/viewer/2022081721/551e4b3c4a795982108b4ad3/html5/thumbnails/5.jpg)
5.3 MAIN CPU
5-5
5.3 MAIN CPU 5.3.1 Connection for updating MAIN CPU The PC is connected to EXTERNAL GPS(AUX-2) port (J6) via RS-232C/RS-422 level converter. See Fig. 5.3.1. Use the level converter of which transmission rate is 9600 bps or more. The interconnection cable and the converter are arranged locally. Make shorts on the COM part of the PC.
.
Fig. 5.3.1 Connection for updating MAIN CPU program
5.3.2 Updating Procedure 1. Turn off the FA-100. 2. Insert the MAIN CPU program disk into the PC. 3. Download all files in the disk to your desktop.
The files are; - Him.bin, Upw.exe : used to download the program - Himmain.mot : Main CPU program
![Page 6: How to Update FA100 Program](https://reader036.fdocuments.in/reader036/viewer/2022081721/551e4b3c4a795982108b4ad3/html5/thumbnails/6.jpg)
5.3 MAIN CPU
5-6
4. Click the “Upw.exe”. The UPW window appears. 5. Select “Loader File”; click SH3 MAIN. 6. Select the PC serial “Port” to be used. When the [COM1] port of the PC is used,
select ”COM1”. 7. Turn on the FA-100. 8. After hearing a beep, click [Start] in UPW window during the presence of the
FURUNO logo on the FA-100 screen. The updating starts automatically.
Fig. 5.3.2 Start-up Sequence
Start button
Port setting Loader File selection
Status window
Press [Start] during this period.
CAUTION: Do this carefully, otherwise a wrong program is installed.
FURUNO logo
plotter display
![Page 7: How to Update FA100 Program](https://reader036.fdocuments.in/reader036/viewer/2022081721/551e4b3c4a795982108b4ad3/html5/thumbnails/7.jpg)
5.3 MAIN CPU
5-7
9. The messages appear in the ”Status” window on the PC. The display of the FA-100 changed to plotter display.
Response waiting from target. Response detection from target. Loading program transmission beginning. Loading program transmission completion. 19694line is transmitted. Now Erasing Writing was completed.
10. Updating is complete with the following message. “Writing was completed.” The necessary time for program update is about 10 minutes. 11. Turn off the PC, and turn it on again.
12. Press [MENU][7] and [1] to confirm the program number and version,
245-0001-00x. Press [CLR], shows the program version in detail; 245-0001-00x0x. Clearing memory after updating Turn on the unit while holding [CLR]. Release the hand when “COMPLETE” appears. After clearing the memory, reset “INTI SETTING” and “SYSTEM SETTING”. See page 8-14.
![Page 8: How to Update FA100 Program](https://reader036.fdocuments.in/reader036/viewer/2022081721/551e4b3c4a795982108b4ad3/html5/thumbnails/8.jpg)
5.4 SUB CPU
5-8
5.4 SUB CPU 5.4.1 Connection for updating SUB CPU The PC is connected in the junction box CB-100 as shown in Fig. 5.4.1. The interconnection cable is arranged locally. Make shorts on the COM port of the PC.
Fig. 5.4.1 Connection for updating SUB CPU
5.4.2 Updating Procedure 1. Turn off the FA-100. 2. Insert the SUB CPU program disk into the PC. 3. Download all files in the disk to your desktop.
The files are; - Him.bin, Upw.exe : used to download the program - Himsub.mot : Sub CPU program
![Page 9: How to Update FA100 Program](https://reader036.fdocuments.in/reader036/viewer/2022081721/551e4b3c4a795982108b4ad3/html5/thumbnails/9.jpg)
5.4 SUB CPU
5-9
4. Click the “Upw.exe”. The UPW window appears. 5. Select “Loader File”; click SH3 SUB. 6. Select the PC serial “Port” to be used. When the [COM1] port of the PC is used,
select ”COM1”. 7. Turn on the FA-100. 8. After hearing a beep, click [Start] in UPW window during the presence of the
FURUNO logo on the FA-100 screen. The updating starts automatically.
Fig. 5.4.2 Start-up Sequence
Start button
Port setting Loader File selection
FURUNO logo
Press [Start] during this period.
CAUTION: Do this carefully, otherwise a wrong program is installed.
Status window
SH3 SUB
![Page 10: How to Update FA100 Program](https://reader036.fdocuments.in/reader036/viewer/2022081721/551e4b3c4a795982108b4ad3/html5/thumbnails/10.jpg)
5.4 SUB CPU
5-10
9. The messages appear in the ”Status” window on the PC. The display of the FA-100
remains unchanged (FURUNO logo).
Response waiting from target. Response detection from target. Loading program transmission beginning. Loading program transmission completion. 19694line is transmitted. Now Erasing Writing was completed.
10. Updating is complete with the following message. “Writing was completed.”
The necessary time for program update is about 15 minutes.
11. Turn off the PC, and turn it on again.
12. Press [MENU][7] and [1] to confirm the program number and version, 245-0002-00x. Press [CLR], shows the program version in detail; 245-0002-00x0x.
Clearing memory after updating Turn on the unit while holding [CLR]. Release the hand when “COMPLETE” appears. After clearing the memory, reset “INTI SETTING” and “SYSTEM SETTING”. See page 8-14.
![Page 11: How to Update FA100 Program](https://reader036.fdocuments.in/reader036/viewer/2022081721/551e4b3c4a795982108b4ad3/html5/thumbnails/11.jpg)
5.5 H8S1/2/3
5-11
5.5 H8S1/2/3 5.5.1 Connection for updating H8S1/2/3 The PC is connected to LOG CONTACT(AUX-1) port (J5) as shown in Fig. 5.5.1. The interconnection cable is arranged locally. Make shorts between #4 and #6, and between #7 and #8 on the COM port of the PC.
Fig. 5.5.1 Connection for updating H8S program
5.5.2 Updating procedure To update H8S1/2/3 program;
Setup to PC 1. Insert the H8S program disk into the PC. 2. Download all files in the disk to your desktop. The files are;
- ComHost.exe, Loader.bin: used to download the program - H8S1.bin: H8S1 program - H8S2.bin: H8S3 program - H8S3.bin: H8S3 program
![Page 12: How to Update FA100 Program](https://reader036.fdocuments.in/reader036/viewer/2022081721/551e4b3c4a795982108b4ad3/html5/thumbnails/12.jpg)
5.5 H8S1/2/3
5-12
Loader File selection Port setting
Start button
3. Click the “ComHost.exe”. The BOOT LOADER window appears. 4. Select “Loader File”; click H8S1.bin, H8S2.bin or H8S3.bin.
5. Select the PC serial “Port” to be used. When the [COM1] port of the PC is used,
select ”COM1”. Setup to FA-100 6. Press [MENU][7] and [7]. The display asks the password to access to the
“SERVICE” menu.
[ENTER PASSWORD] PASSWORD:
7. Type password (xxxxxx) followed by [ENT], and the service menu appears.
[FOR SERVICE] 1 TX/RX TEST 2 SIO TEST 3 ALARM HISTORY 4 SET CH&PWR 5 H8S RESET
Status window
CAUTION: Do this carefully, otherwise a wrong program is installed.
![Page 13: How to Update FA100 Program](https://reader036.fdocuments.in/reader036/viewer/2022081721/551e4b3c4a795982108b4ad3/html5/thumbnails/13.jpg)
5.5 H8S1/2/3
5-13
8. Press [5] to select ”H8S RESET”. “H8S LOADER RESET menu” is displayed.
[H8S LOADER RESET] H8S1 RESET H8S2 RESET H8S3 RESET
9. Select the loader to be reset by using [!] or ["] key and press [ENT]. The menu changes to ”H8S RESET”.
[H8S RESET] H8S x PROGRAM
LOADING…… Start 10. Click [Start] in the BOOT LOADER window. The new program is installed on
to the FA-100 automatically. The messages appear in “Status” window. The FURUNO logo on the FA-100 is remains unchanged.
Loader transmission preparation. Loader transmission preparation completion. LSI initialization instruction. LSI initialization completion. Loader program byte number beginning. Loader program byte number transmitting completion. Loader program transmitting beginning. Loader program byte number transmitting completion. Loader program transmitting beginning. Loader program transmitting end. The main program saving preparation. The main program saving preparation. . . Completion Transmission bytes number transmission beginning. Transmission bytes number transmission beginning . . . Completion The main program forwarding beginning. Checksum calculation beginning. . . .Completion
11. Updating is complete with the following message.
“Checksum calculation beginning. . . .Completion” The necessary time for program update is;
- H8S1 and H8S2: about 5 minutes - H8S3: about 8 minutes
Note: To close this window, turn off the PC.
![Page 14: How to Update FA100 Program](https://reader036.fdocuments.in/reader036/viewer/2022081721/551e4b3c4a795982108b4ad3/html5/thumbnails/14.jpg)
5.5 H8S1/2/3
5-14
12. Turn off the PC, and turn it on again. 13. Press [MENU][7] and [1] to confirm the program number.
- H8S1 : 245-0003-001 - H8S2 : 245-0004-001 - H8S3 : 245-0005-001
Press [CLR], shows the program version in detail. - H8S1 : 245-0003-0010x - H8S2 : 245-0004-0010x - H8S3 : 245-0005-0010x
If the program number is wrong, repeat above steps. (A wrong program is loaded if the load file selection is incorrect.)