How to Setup and Configure a High Speed Ethernet Device ...

24
G1010 Revised 1/15/2014 HOW TO How to Setup and Configure a High Speed Ethernet Device Using FF Power Alert Snap-On

Transcript of How to Setup and Configure a High Speed Ethernet Device ...

G1010Revised 1/15/2014

HO

W T

O

How to Setup and Configure a High Speed Ethernet Device Using FF Power Alert Snap-On

2 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 3

ABOUT THIS GUIDEThis “How to” is designed to show the user how to setup and configure a high speed Ethernet (HSE) device using FF

Power Alert Snap-On.

REQUIRED PARTS

Hardware• Any Foundation Fieldbus Device

• DELTAV Hardware - MD/MD PLUS

• DPC-49-ADU

• DPC-49-HSEFD/24VDC - Firmware 2.2.5.3

• DPC-49-IPS1

• DPC-49-4RMB

Software• FF Power Alert Snap-On

• Delta V Exployer - Version 9.3

www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 3

DOWNLOAD / INSTALL FF POWER ALERT SNAP-ONGo to: https://app.box.com/s/tkaqmahol7bpdyvaebpy

Click of “Download”

Once downloaded, Click on “DpcAmsServer.exe” and follow the rest of the install instructions.

4 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 5

DELTA V EXPLORER

Install a Live DeviceGo into delta V exployer and install a live device on your foundation feild bus network.

www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 5

Right click on device and click Properties.

6 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 7

Notice this device is a Yokogawa Electric and an EJX device.

www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 7

Right Click and put device in standby mode. (This will take about one minute)

8 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 9

Notice the Icon has now changed

www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 9

Right Click on “PO1” and click “New Fieldbus Device”

10 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 11

Create the new device to be an exact clone of the attached device. Is this example we change the Manufacture to

“Yokogawa Electric” and the “Device Type” to “EJX” by using the drop down arrows. When done, click “OK”.

www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 11

Notice that “DPC-49-HSEFD” pick up on the “Standby” device. Click OK.

12 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 13

Go through the wizard

Next

Next

Finish

www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 13

Wait for the device to commission. (This will take about one minute)

Notice “DPC-49-HSEFD has come online. Right-click on “CTLR-01128C” -> Download -> Controller

14 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 15

Navigate through the downloader.

Yes

Close

www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 15

Right-click on “DPC-49-HSEFD” -> “Open with AMS Device Manager”

16 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 17

Notice the manager opens right up into the tag database. Notice the tag has a specific ID number.

Right-click the Snap-On (The little TURCK “T” located in the quick launch icons) -> Options.

www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 17

Check “AMS device tag” in “Options List” and make sure it matches the “Tag ID” in the “Tag Data Base”.

When you are finished matching the “Tag Id” numbers, Click “OK” and then click the “X” on the “Tag Data Base.”

Notice the “Device Connection View” pop-ups.

18 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 19

Right-click on “TURCK Delta Network” -> Rebuild Hierarchy

If you expand the tree you will see the “DPC-49-HSEFD_01” tag

Double-click on “Plant Database” and expand the tree. Drag and Drop the“DPC-49-HSEFD_01” tag into the “Control

Module” folder. (This will take a sometime to process)

Once complete, go to “View” -> “Alert Monitor”

www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 19

When the monitor opens we need to add a tag to the alert list, Click “Configure” -> “Add” -> select the tag-> OK

Notice the tag showed up in the “Device Monitor List”. All alerts will now be displayed in the “Alert List”.

20 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 21

MANUALLY TURN ON AN ALARMThis section will generate an alarm.

Open Internet Explorer and type in the device IP address into the navigation bar. Press “Enter”. The devices web server

screen will pop up.

Change the “Alarm Noise” “Threshold Hi” text box from 111.0 to 2.0.

www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 21

Click “Apply changes”

Notice the “Snap-On” pop-up notifies the user of a “Pre-Alarm” due to the “Noise Value” being 2.0mV

22 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 23

Click over to the “Alert List”. Notice an alarm has popped up. (It may take up to one minute for the alarm to show up in

the “Alert List”).

Click on the “Unacknowledged” tab and then click on “Acknowledge” to acknowledge this alert.

Once the alert has been acknowledged, click over to the “Active Alerts” tab.

Notice the alert is still active. Now let’s clear the alert.

www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 23

MANUALLY TURN OFF AN ALARMGo back to web server and change the “Alarm Noise” “Threshold Hi” text box from 2.0 to 110.0.

Click “Apply changes”

24 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 www.turck.com • 1-800-544-7769 • Fax: (763) 553-0708 • TURCK • Minneapolis, MN 55441 PB

Open the “Alert List”. After about a minute you will see a Snap-On pop-up tell you that the “Noise Value” is good.

After about a minute, the active alert will clear from the “Alert List”.