1 How to Properly Specify a UV System for Disinfecting Water or Wastewater Water Arabia 2011 Gulf Hotel Bahrain Water Arabia 2011 Gulf Hotel Bahrain January 31 to February 2, 2011 January 31 to February 2, 2011 G. Elliott G. Elliott Whitby Whitby, PhD , PhD Principal Scientist Principal Scientist Calgon Calgon Carbon Corporation Carbon Corporation 7100 Woodbine Ave., Suite 310 7100 Woodbine Ave., Suite 310 Markham, Ontario, Canada Markham, Ontario, Canada L3R 5J2 L3R 5J2 Telephone: 416 Telephone: 416-399 399-3118 3118 Fax: 905 Fax: 905-477 477-7355 7355 E-mail: mail: ewhitby@calgoncarbon ewhitby@calgoncarbon-us.com us.com

Transcript of How to Properly Specify a UV System for …1 How to Properly Specify a UV System for Disinfecting...

Page 1: How to Properly Specify a UV System for …1 How to Properly Specify a UV System for Disinfecting Water or Wastewater Water Arabia 2011 Gulf Hotel Bahrain January 31 to February 2,

1

How to Properly Specify a UV System for Disinfecting Water or

WastewaterWater Arabia 2011 Gulf Hotel BahrainWater Arabia 2011 Gulf Hotel Bahrain

January 31 to February 2, 2011January 31 to February 2, 2011

G. Elliott G. Elliott WhitbyWhitby, PhD, PhDPrincipal ScientistPrincipal Scientist

CalgonCalgon Carbon CorporationCarbon Corporation7100 Woodbine Ave., Suite 3107100 Woodbine Ave., Suite 310

Markham, Ontario, CanadaMarkham, Ontario, CanadaL3R 5J2L3R 5J2

Telephone: 416Telephone: 416--399399--31183118Fax: 905Fax: 905--477477--73557355

EE--mail: mail: ewhitby@[email protected]

Page 2: How to Properly Specify a UV System for …1 How to Properly Specify a UV System for Disinfecting Water or Wastewater Water Arabia 2011 Gulf Hotel Bahrain January 31 to February 2,

2

Advantages of Using UV Light to Disinfect Water or Wastewater

Physical process not a chemical process: Water chemistry & characteristics, such as pH, taste, odor, color etc. are unchanged

Fast kinetics - reaction time in seconds: Minimizes building requirements

Does not create toxic compounds which may affect humans when they consume drinking water

Does not create toxic compounds in wastewater that may affect the aquatic biota or a source of drinking water

Inactivates viruses and vegetative and spore forming bacteria inwastewater where chlorine is affected by ammonia

Inactivates Cryptosporidium and Giardia whereas chlorine does not

Is cost competitive with chlorination, ozonation and chlorination/dechlorination

Eliminates handling and storing of dangerous toxic chemicals Very few moving parts Environmentally responsible and increasingly accepted

technology

Page 3: How to Properly Specify a UV System for …1 How to Properly Specify a UV System for Disinfecting Water or Wastewater Water Arabia 2011 Gulf Hotel Bahrain January 31 to February 2,

3

Open Channel UV Disinfection of Wastewater for Discharge or Reuse

Page 4: How to Properly Specify a UV System for …1 How to Properly Specify a UV System for Disinfecting Water or Wastewater Water Arabia 2011 Gulf Hotel Bahrain January 31 to February 2,

4

Pressurized UV Disinfection of Drinking Water or Wastewater for Reuse

Page 5: How to Properly Specify a UV System for …1 How to Properly Specify a UV System for Disinfecting Water or Wastewater Water Arabia 2011 Gulf Hotel Bahrain January 31 to February 2,

5

UV Dose or Fluence(mW.sec/cm2 or mJ/cm2 or J/m2)

Quantity of UV Light That Does the Work

Dose = I x TI = Intensity (mW/cm2 or W/m2)

T = Time (seconds)

It is how this Dose is specified that willIt is how this Dose is specified that willaffect the operation of the UV system and its successaffect the operation of the UV system and its success

Page 6: How to Properly Specify a UV System for …1 How to Properly Specify a UV System for Disinfecting Water or Wastewater Water Arabia 2011 Gulf Hotel Bahrain January 31 to February 2,

6

Calculated Dose vs Bioassay Dose ???A bioassay dose is the only acceptable

method for sizing a UV system for drinking water anywhere in the world

Calculated doses are used for wastewater: This is not acceptable

A bioassay dose is the only acceptable method for sizing a UV system for water reuse in North America

Page 7: How to Properly Specify a UV System for …1 How to Properly Specify a UV System for Disinfecting Water or Wastewater Water Arabia 2011 Gulf Hotel Bahrain January 31 to February 2,

7

Why a Calculated Dose is not Acceptable UVDIS: Most Commonly Used Sizing ProgramDeveloped by HydroQual Inc. for the U.S. EPA in the

1980’sFour Sections:

1. Tulip: Determines the average intensity within the lamp array

2. UV Unit: Describes all the characteristics of the UV system and the number of banks in series

3. Wastewater and disinfection limit4. Output It is highly dependent on the lamp output It does not account for system hydraulics

Page 8: How to Properly Specify a UV System for …1 How to Properly Specify a UV System for Disinfecting Water or Wastewater Water Arabia 2011 Gulf Hotel Bahrain January 31 to February 2,

8

UVDIS: Output of Intensity Calculation

Very dependent on UV lamp output30 % Lamp Efficiency 170 Lamps45 % Lamp Efficiency 94 Lamps

Page 9: How to Properly Specify a UV System for …1 How to Properly Specify a UV System for Disinfecting Water or Wastewater Water Arabia 2011 Gulf Hotel Bahrain January 31 to February 2,

9

11.21.41.61.8

22.22.4

0 5 10 15 20 25 30 35

Temperature C

UV

Inte

nsity

mW

/cm2 G64T5L 525 mA

G64T5L 425 mA

Effect of Lamp Current on UV OutputInside a Quartz Sleeve Underwater

37 % Increase in Intensity

Page 10: How to Properly Specify a UV System for …1 How to Properly Specify a UV System for Disinfecting Water or Wastewater Water Arabia 2011 Gulf Hotel Bahrain January 31 to February 2,

10

It is a microbiological method of determining the delivery of UV light by a UV system under specific conditions of the UV unit and the water.It detects the actual affect of: UV Transmission on UV Intensity Flow Rate on UV System Hydraulics Lamp Output: Real Lamp Output

What is a Bioassay?

Page 11: How to Properly Specify a UV System for …1 How to Properly Specify a UV System for Disinfecting Water or Wastewater Water Arabia 2011 Gulf Hotel Bahrain January 31 to February 2,

11

Other Benefits of a BioassayWith the introduction of electronic ballasts, proprietary lamps and lamp configurations all the UV systems are different so they are very difficult to compare.Allows the comparison of low and medium pressure UV lampsUnder similar conditions a bioassay insures that the UV dose claimed by the manufacturer is actually delivered by the UV equipment.A bioassay confirms the UV output of the UV lamps under actual operating conditions as versus measurements in air.A bioassay eliminates any disagreements that may take place over how to calculate the UV dose within a reactor.Ensures the UV system will operate under worse case conditionsThe lamps will last longer since fewer will be on all the timeLower power consumptionLonger periods between cleaning

Page 12: How to Properly Specify a UV System for …1 How to Properly Specify a UV System for Disinfecting Water or Wastewater Water Arabia 2011 Gulf Hotel Bahrain January 31 to February 2,

12

Basic Steps in a Bioassay Hire a third party to independently test the UV system Select a microorganism that is UV resistant, not

pathogenic and easy to grow Irradiate the microorganisms with exact UV doses to

create a calibration curve of UV dose versus log inactivation

Set-up a UV system to simulate worst case conditions of the lamps and water

Put the calibrated microorganisms through the UV unit at different flow rates and measure the test organism in the influent and effluent to get the log inactivation

Using the calibration curve create a curve of flow per lamp versus UV dose at different UV transmissions

Create a third party report describing the exact test conditions and results

How is a Bioassay Performed?

Page 13: How to Properly Specify a UV System for …1 How to Properly Specify a UV System for Disinfecting Water or Wastewater Water Arabia 2011 Gulf Hotel Bahrain January 31 to February 2,

13

Schematic of a BioassayMS2 & T1 Dosing

Valve

Pump

Flow Meter

UV Bank

PDCSampling Area

Page 14: How to Properly Specify a UV System for …1 How to Properly Specify a UV System for Disinfecting Water or Wastewater Water Arabia 2011 Gulf Hotel Bahrain January 31 to February 2,

14

Effect of Lamp Output on the UV Dose of an Open Channel UV System

0

20000

40000

60000

80000

100000

120000

140000

0 20 40 60 80 100 120 140 160 180Flow in Litres per Minute per Lamp

Flue

nce

mic

roW

.sec/

cm2

400 mA425 mA450 mA470 mA525 mA

G64T5L UV Lamp3 Inch Spacing20 mm by 23 mm Quartz Sleeve

MS2 Coliphage Bioassay 65 %T Drinking Water

Page 15: How to Properly Specify a UV System for …1 How to Properly Specify a UV System for Disinfecting Water or Wastewater Water Arabia 2011 Gulf Hotel Bahrain January 31 to February 2,

15

Standard Bioassay Test ProtocolsNWRI/AWWARF UV Guidelines

Water ReuseETV/EPA/NSF Program

StormwaterSecondary EffluentWater Reuse

German DVGW W294 Drinking WaterAustrian ONORM 5873-1 Drinking WaterUS EPA UVDGM

Only Acceptable Method for Drinking Water in USA

Page 16: How to Properly Specify a UV System for …1 How to Properly Specify a UV System for Disinfecting Water or Wastewater Water Arabia 2011 Gulf Hotel Bahrain January 31 to February 2,

16

Example of a Bioassay Based Standard NWRI/AWWARF UV GuidelinesThe effluent must meet the following standard: Secondary Treatment Coagulation Filtration Less than 5 mg/L TSS 5 Log Poliovirus Inactivation 7 Day Median of 2.2 Total Coliforms per 100 mL by

the MPN Method

Page 17: How to Properly Specify a UV System for …1 How to Properly Specify a UV System for Disinfecting Water or Wastewater Water Arabia 2011 Gulf Hotel Bahrain January 31 to February 2,

17

Dose Requirements by a Bioassay with MS2 Coliphage by a Third Party

Media Filtration 100 mJ/cm2

> 55 % UVT Less than 5 mg/L TSS

Membrane Filtration 80 mJ/cm2

> 65 % UVT 0.2 NTU

Reverse Osmosis 50 mJ/cm2

> 90 % UVT 0.2 NTU

Page 18: How to Properly Specify a UV System for …1 How to Properly Specify a UV System for Disinfecting Water or Wastewater Water Arabia 2011 Gulf Hotel Bahrain January 31 to February 2,

18

Specifying the Dose Delivered by a UV System with a Bioassay is the

Only Acceptable Method

Page 19: How to Properly Specify a UV System for …1 How to Properly Specify a UV System for Disinfecting Water or Wastewater Water Arabia 2011 Gulf Hotel Bahrain January 31 to February 2,

19

Thank you