DINNING
ROOM
KITCHEN
BATHROOM
LOUNGE
BEDROOM TO
T.V ROOM
PORCH
SINGLE GARAGE
BEDROOM 1
BEDROOM 2
MASTER
BEDROOM
EN-SUITE
EN-SUITE
EX. BALCONY
up
up
sliding door
sliding door
SITE AND GROUND FLOOR PLAN
FIRST FLOOR PLAN
arch
EX. BALCONY
NEW PATIO
remove wall
NEW PRAYER
ROOM
fit new folding/stack
doors
existing window
re-positioned
rc slab (shown
crossed) to engineers
detail above
demolish exist. wall, replace
with balustrading at 1.05m
high
patio door
EXIST
WALL
BIC
reinforced concrete
flat slab to engineers
detail
PROPOSED ADDITIONS AND
ALTERATIONS TO DWELLING
LOT 4715 QUEENSBURGH
AT
15 SANDPIPER STREET
FOR
MR & MRS NAICKER
ON
CLIENTS SIGNATURE
DATE
CROSSMOOR
TEL./FAX. 031-4093357
MOBILE: 082 3227362
375 CROSSMOOR DRIVE
CHATSWORTH . DURBAN . 4092
PR.NO. ST-20559 (S.A.C.A.P) KZ-NIA (affiliate)
DRAWN
PROJECT NO
DRAWING NO
DATE
DESIGN
SCALE
r a j e s h
ASHARAM
A R C H I T E C T U R E
1:100
01
CHECKED
Author/ Architect
Drawing Title
R. ASHARAM
R. ASHARAM
PLANS/ ELEVATIONS
25 July 2012
Project
SOUTH WEST ELEVATION
rc slab to engineers
detail above
Roof tiles on 38x38 battens on 250
microns plastic underlay on
pre-fabricated trusses (gangnailed) on
114x38mm wall plates tied down at
least 8 courses into brickwork
tiled roof
existing roof
NORTH WEST ELEVATION
Roof tiles on 38x38 battens on 250
microns plastic underlay on
pre-fabricated trusses (gangnailed) on
114x38mm wall plates tied down at
least 8 courses into brickwork
new powder-coated aluminum
'fold/stack doors', plaster band
surround.
NORTH EAST ELEVATION
Roof tiles on 38x38 battens on 250
microns plastic underlay on
pre-fabricated trusses (gangnailed) on
114x38mm wall plates tied down at
least 8 courses into brickwork
SOUTH EAST ELEVATION
existing Marseilles tiled roof
Roof tiles on 38x38 battens on 250
microns plastic underlay on
pre-fabricated trusses (gangnailed) on
114x38mm wall plates tied down at
least 8 courses into brickwork
rc slab to engineers
detail above
SECTION A - A
Roof tiles on 38x38 battens on 250
microns plastic underlay on
pre-fabricated trusses (gangnailed) on
114x38mm wall plates tied down at
least 8 courses into brickwork
rwdp rwdp
rwdp rwdp
rwdp
rwdp
A
A
10
00
b
uild
in
g lin
e
2000 building line
2000 building line
SANDPIPER STREET
SINGLE GARAGE
MASTER
BEDROOM
dry-stack rockwork to
architects detail
46
60
14
02
86
01
52
01
40
6400
29301740 1740
140140
1500
60
0
24
60
14
00
10
60
14
0
14
0
1650
4240
2503401360290
2000
20
40
2700
6410
63090015001250
140
1500630
140
30
00
44
02
56
0
14
01
40
LOT 4714
remove exist. window & wall,
re-use window to new wall as
shown and make good.
remove door & brick
up opening
remove door & brick
up opening
LOT 4716
156.86157.8
158.4157.5
1950
gully
gully
r.e
i.e
i.e
i.e
i.esvp
r.e
T
O
E
X
I
S
T
I
N
G
S
T
O
R
M
W
A
T
E
R
C
O
N
N
E
C
T
I
O
N
TO
E
XIS
TIN
G S
EW
ER
C
ON
NE
CT
IO
N
r.e to be encased in
concrete under patio
concrete slab to
engineers detail
25
00
25
00
new roof and tiles to
match existing house
at a min. pitch of 15°.
new roof and tiles to
match existing house
at a min. pitch of 15°.
CONTRACTER TO ENSURE THAT NO CHANGES IN
LEVELS ARE MADE OVER LOCAL AUTHORITY
SERVITUDES OR UNDER GROUND SERVICES UNLESS
PERMISSION HAS BEEN GIVEN IN WRITING BY
THE LOCAL AUTHORITY.
ANY DISCREPANCIES AND OMISSIONS ARE TO BE
BROUGHT TO THE ARCHITECTS ATTENTION
IMMEDIATLY.
IF ON EXCAVATION THE SITE IS FOUND TO
CONTAIN EXPANSIVE CLAY, SHALE, GROUND WATER
OR OTHER SUSPECT SOIL CONDITIONS : THEN ALL
FOUNDATIONS ARE TO BE BUILT TO PROFESSIONAL
ENGINEERS DETAILS & UNDER HIS SUPERVISION.
ROOF NOTES
ROOF TILES TO MATCH EXISTING HOUSE OR CLAY TILES
ON 38 x 38 BATTENS ON 250 MICRONS UNDERLAY ON
GANGNAIL PLATED TIMBER TRUSSES DESIGNED AND
CERTIFIED BY ENGINEER WITH 17 degree PITCH UNLESS
OTHERWISE SPECIFIED AT 740 CENTERS WITH TRUSSES
FIXED USING GALVANIZED HOOP IRON METAL STRAPS
TIED DOWN SIX COURSES INTO BRICKWORK
DRAINAGE NOTES
- ALL WORK IS TO COMPLY TO SANS 10400
- HEAD OF DRAIN IS TO BE VENTED
- ANY DAMAGED FITTINGS TO BE REPLACED
- ALL GULLY SURROUNDS & MANHOLE
COVERS TO BE 75 mm ABOVE GROUND LEVEL
- SEWER MANHOLES TO BE EXPOSED BEFORE
COMMENCING WORK AND ADJUST LEVELS
ACCORDINGLY
- IE'S TO ALL BENDS AND JUNCTIONS
- SOIL PIPES TO BE 110 diameter PVC
- SEWER UNDER BUILDINGS TO BE
110 mm PVC RIBBED PIPE
- ANCHOR BLOCKS TO BE USED WHEN
GRADIENTS EXCEED 1:5
GENERAL NOTES
ALL WORK TO COMPLY WITH SANS 10400.
CORNER BEACONS TO BE LOCATED AND
EXPOSED BEFORE WORK ON SITE COMMENCES.
CONTRACTOR TO CHECK ALL DIMENSIONS AND
LEVELS (SCHEDULES AND DETAILS) BEFORE THE
RELEVANT WORK IS PLACED IN HAND AND REPORT
ANY DISCREPANCIES TO THE ARCHITECT.
ALL WRITTEN DIMENSIONS TO BE TAKEN IN
PREFERENCE TO SCALING.
SOIL TO BE WELL COMPACTED BEHIND IN LAYERS
NOT EXCEEDING 150 mm.
ALL FOUNDATIONS TO BE TAKEN BELOW NATURAL
GROUND LEVEL.
NO BACK FILLING OF OVER EXCAVATED AREAS WILL
BE PERMITTED.
FIBRE CEMENT BARGE AND FASCIA BOARDS , PVC
GUTTERS & DOWN-PIPES ALL TO MATCH EXISTING
HOUSE WHERE POSSIBLE AND TO BE FIXED IN
ACCORDANCE WITH MANUFACTURES SPECIFICATIONS
OVERHANG TO MATCH EXISTING HOUSE OR 3 TILE
OVERHANG.
FLASHING TO COMPLY WITH PART LL5.2
TWO COURSE OF BRICKWORK TO BE REINFORCED
WITH BRICKFORCE BELOW WALL PLATE LEVEL, ABOVE
WINDOW HEAD HEIGHT & BELOW WINDOW SILL LEVEL.
EXTERNAL FACE OF INNER SKIN OF ALL EXTERNAL
WALLS TO BE BAGGED AND WATERPROOFED
WITH TWO COATS OF BITUMEN PAINT.
6.4 mm GYPSUM CEILING BOARDS FIXED TO 38 X 38
BRANDERING AT MAX 300mm CENTERS BOTH WAYS.
375 mic DPC TO BE PROVIDED TO WALLS AT SLAB
LEVEL AND UNDER ALL SILLS.
THE CONTRACTOR IS TO INSPECT THE OFFICIAL
APPROVED COPIES OF THE DRAWINGS TO ENSURE
THAT ALL AMENDMENTS HAVE BEEN TAKEN INTO
ACCOUNT .
THE ATTENTION OF THE OWNER/CONTACTOR
IS DRAWN TO THE FACT THAT CHANGERS TO THE
PLAN &/OR SPECIFICATION AFTER OFFICIAL APPROVAL
IS LIKELY TO INVALIDATE THAT APPROVAL.
ALL EARTHWORKS TO BE CONTAINED WITHIN SITE
BOUNDARIES & WITHIN 1.0 m OF ANY of ANY
BOUNDARY.
BANKS TO BE CUT AT A MAXIMUM OF 26 degrees.
NATURAL GROUND LINE IN APPROXIMATE POSITION
ONLY & NO CLAIM CAN BE MADE FOR ANY
DISCREPANCIES
ON SITE.
SUB-FLOOR AND FOUNDATION TRENCHESTO BE
POISONED WITH "CLORODANE" SOLUTION IN
ACCORDANCE WITH SANS CODES OF PRACTICE BY
SPECIALIST.
NOTE: ALL DIMENSIONS - LEVELS ETC. ARE TO BE
VERIFIED ON SITE PRIOR TO ANY WORK BEING PUT IN
HAND AND TO REPORT ANY DECREPANCIES
IMMEDIATELY TO THE ARCHITECT
ALL MATERIALS AND LABOR PRACTICE IS TO COMPLY
WITH PART-B OF SANS 10400.
AND NATIONAL BUILDING REGULATIONS
100mm concrete slab reinforced with
BRC mesh (ref 193) on plastic underlay
in well compacted soil.
concrete flat slab to
engineers detail
B
B
36
70
B
B
73
10
balustrading at 1.05m
APEX
WPL
FIRST FLOOR FFL
GROUND FLOOR FFL
APEX
WPL
FIRST FLOOR FFL
GROUND FLOOR FFL
APEX
WPL
FIRST FLOOR FFL
GROUND FLOOR FFL
NGL
NGL
NGL
APEX
WPL
FIRST FLOOR FFL
GROUND FLOOR FFL
NGL
A
A
Roof tiles on 38x38 battens on 250
microns plastic underlay on
pre-fabricated trusses (gangnailed) on
114x38mm wall plates tied down at
least 8 courses into brickwork
new roof and tiles to
match existing house
at a min. pitch of 15°.
EN-SUITE
MASTER
BEDROOM
BEDROOM TO
T.V ROOM
NEW PATIO
SINGLE GARAGE
600x200
600x200 600x200 600x200
25
00
25
00
concrete slab to
engineers detail
SECTION B - B
T
R
U
E
N
O
R
T
H
str
ong s
um
m
er w
inds
win
ter r
ain
& w
inds
s
u
n
r
i
s
e
s
u
n
s
e
t
Y.SEWPERSAD