1.System Composition
Main Switch
RouteWork
Monitor server
Internet
Smart-Hotel System schematic diagram
Floor switch 1
Distribution box
Host 1
Floor switch 2
Foreground
10/100M Ethernet
Public control Distribution box
Distribution box
Host 2
Distribution box
Host N
……more
……More floor
Smart-Hotel System schematic diagram
Touch PanelMaster CardDoor Bell
PanelEmergency
AC
220V
Power supply Multi function output moduleHotel room control host
INNER BUS
Energy-saving lamp TV Lighting Fan
Connect with other rooms
Floor Switch
Eth
ern
et
Motor Others
Host distribution box
Motion SensorAir Condition
Panel
Air condition system
S-BUS
Diagram for DEMO board
L
N
INNER-BUS
S-BUS
Master Card Panel DLP
Z-Audio
Mix18
Room lampsFAN( to simulate an AC)Door
Speaker
Door Bell
Ethernet Room HostPower
L N
2. system application
• 1 Add a Room• 2 Issue a Room card• 3 Open the door with a room card• 4 Insert a card for power• 5 panel application : Lamp/AC control• 6 panel application : Set service status
clear-up/laundry/DND• 7 panel application: Playing music
Functions Show
1. Add a Room
Step1. Launch the Hotel Manage Software
Click ‘Add Room’ icon to add a room
1. Add a Room
Step2. search room host
Step3. select a device (room host)
Step4. click to Add room (save and exit)
③② ④
1. Add a Room
Step5. Click to view/edit
1. Add a Room
Step6. Set Child module(Mix18) start loop
2.Right click here
1. Press the setting button of Multi function output module(Mix18) till the LED turn to red
1. Add a Room
Step6. Set Child module(Mix18) start loop
3.Click to read start loop and set to loop1
1. Add a Room
Step7. ① click to enter ’setup model’, ② enable Miracle Data Transmit ( 2 icon turn to black and white color).
① ②
Card Writer
(USB device, link to host PC)
2. Issue a Room Card
2. Issue a Room Card
Step1. Click ‘CardReader’ icon to read and write a room card
2. Issue a Room Card
Step2 Card Read
Step3 set
Card Type: guest/Visitor
Valid Time: Today+Add
Valid Area Count: 1
Valid Area:
Build 01
Floor 01
Room 101
Step4 Card Write
②
③
④
3. Open the door with a Room card
Lock
unlock
3. Open the door with a Room card
①
② ③
Step1. S-BUS software > door bell > Key assignation
Step2. select Key no.2 RF switch
Step3. Setup a relay to unlock/lock the door(CH16 relay on demo board)
3. Open the door with a Room card
Step4. Auto lock setting
When connecting a door magnetic sensor to one of the 2 Dry contacts, we can set it trigger to lock the door( once the sensor detect the door closed for a preset time)
Step5. set Room information( match with RF room card)
3. Open the door with a Room card
Set Building / Floor / Room number
4. Insert a card for power
——Intelligent ID Identify
Identified by the card, guest or waiter, will get differ control right to
the room’s panels and devices by differ preset scene.
4. Insert a card for power
Step1: view/edit ID from ‘Basic information’ label
Step2: set Hotel Panel Setting in ‘basic setting’ label
Enable/disable card authentication: if disabled, even a blank card will gain the right of room devices’ controlling
step1 step2
4. Insert a card for power
Step3: set Card-Reader ID (enter a room > Setup mode > Room
system data > ’Other’ label )
Step4: set Guest leave delay time
We will set a scene ( when take out the room card, will trigger this scene to switch off all devices after ‘delay time’)
4. Insert a card for power
Click to modify
①②
Step5: appoint a scene order(4) for Occupancy – Null Scene
4. Insert a card for power
1.Selce Occupancy-Null Scene
2.Click to modify
3. Appoint scene4 for Occupancy-Null Scene
4. Insert a card for power
Step6: appoint a scene order(8) for Occupancy – Visitor Scene
1.Selce Occupancy-Visitor Scene
2.Click to modify
3. Appoint scene8 for Occupancy-Visitor Scene
4. Insert a card for power
Step7: setup scene4( Occupancy – Null Scene)
②
①
Select and double click
2.Select all targets
2.Enbale to control set all loop light to 0
1.Enbale scene
4. Insert a card for power
Step8: setup scene4( switch off all devices)
4.Save
4. Insert a card for power
Step9: setup scene8( welcome scene, run for guest’s first enter)
②
①
Select and double click
4. Insert a card for power
Step10: edit scene8 for Occupancy – Null Scene
1.Select targets
2.Enbale to edit
3.Enbale scene4.Save
4. Insert a card for power
Step11: Save all settings to Module when finished
Click to save
②
①
5. Panel application: lamps/AC control
①②
Step1: select a key and set Mode
Step2: set control target(s): AC(CH1/2/3), Lamps( CH6/7/8/9), Dimming lamps(CH17/18)
6. Panel application: set service status
Press a key to set in room.
Show status outside
6. Panel application: set service status
Step1: set Mode to single on/off
Step2: set target Universal switch
1--Luandry, 2--DND,3--Clear-up
① ②
7. Panel application: Playing music
control
S-BUS
Step1: find your Z-Audio from S-BUS
A SD-card (format by FAT32) is needed, to insert into the Z-Audio before power on.
7. Panel application: Playing music
Step2: Set on DLP’s Music page label, add Z-Audio’s subnet ID and device ID, and Zone No.(Zone No.: each DLP can control 24 Z-Audio, so DLP has 24 Zone No. for Z-Audio control.)
7. Panel application: Playing music