Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage...

52
Hot Water Balancing Inside this issue 2010 Internet Usage Survey Safety and Low Flow Showerheads Product Application: Rainwater Harvesting pe12_pgs_01_03_Layout 1 11/30/10 2:40 PM Page 1

Transcript of Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage...

Page 1: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Hot Water Balancing

Inside this issue• 2010 Internet Usage Survey

• Safety and Low Flow Showerheads

• Product Application: Rainwater Harvesting

pe12_pgs_01_03_Layout 1 11/30/10 2:40 PM Page 1

Page 2: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

1.800.438.6091 / www.charlottepipe.com

Don’t redefine the engineer assessment. Remember, they’re called specifications for a reason.When an engineer specifies cast iron pipe for a specific job, it’s because they believe it’s the right material needed to get the job done correctly and efficiently. Engineers know that using cast iron instead of plastic for specific jobs eliminates costly extra steps for things like fire-stopping, noise reduction and thermal expansion. And they know that even after the extra steps are taken to make plastic comparable to cast iron, plastic is still outperformed because it’s just the wrong material for the job. Simply put, there’s a time for plastic and a time for cast iron. The time for cast iron being when the engineer specifies it. Because if you think about it, they don’t call them specifications for nothing.

Suggestifications [suh g-jest-uh-fi-kay-shuns]: n. vague descriptions or loose assessments of what a job may or may not need. The engineer suggestifications stated cast iron pipe so they chose plastic.

Circle 1 on Reader Reply Form on page 49

pe12_pgs_01_03rev_Layout 1 12/1/10 8:37 AM Page 2

Page 3: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

TM

Circle 2 on Reader Reply Form on page 49

pe12_pgs_01_03rev_Layout 1 12/1/10 8:37 AM Page 3

Page 4: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Page 4/Plumbing Engineer December 2010

INDUSTRY NEWS &OTHER DEPARTMENTS

8 | Solar to shine at 2011 AHRExpo

8 | ECR International, National Gridand Suny College of EnvironmentalScience and Forestry announcepartnership

8 | Liberty Pumps holds annual repmeeting at ASPE

8 | NFPA Conference & Expo to participate in U. S. DOC program

10 | St. Louis City residentialredevelopment project breaksground

10 | Grundfos to establish globalcompetency center

40 | THE LEAD FREE REPORT

42 | PRODUCT APPLICATION: Jay R. Smith Mfg. Co

48 | MOVERS & SHAKERS

48 | CLASSIFIEDS

49 | AD INDEX

50 | NEW PRODUCTS

COLUMNS

Volume 38, Number 10, October 2010

FEATURES

INSIDE THIS ISSUE

6 Editor’s Letter: The Progress of Efficiency14 Designer’s Guide: Unexpected Problems20 Code Classroom: Fuel Gas Codes Address Dangers Associated

with Purging of Fuel Gas Pipes28 FPE Corner: Pressure Regulation in Standpipe and Sprinkler Systems32 Heating Help: What a Year!36 Solar Solutions: The Solar Combisystem Heat Exchanger

Hot Water BalancingIt is a requirement of any plumbingsystem with more than one hotwater return path.

Story on page 44

Safety and Low FlowShowerheadsKnowing the type of valve that isbehind the shower wall could havean influence on purchase-makingdecisions.

Story on page 46

2010 Internet Usage SurveyThis exclusive Internet Usage Surveyreveals the online habits of today’sbusy engineer.

Story on page 43

pe12_pgs_04_05rev_Layout 1 12/1/10 7:24 AM Page 4

Page 5: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Circle 3 on Reader Reply form on page 49

pe12_pgs_04_05rev_Layout 1 12/1/10 8:38 AM Page 5

Page 6: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

While attending the latest Greenbuild show in Chicago I got to thinking of

how popular the show really is. In a time where trade shows are dying off,

Greenbuild continues to thrive. Why? Does the word “green” attract the

granola people and tree huggers in droves? Well, not at this show. Professionals

among the ranks of plumbing and mechanical engineers, architects, designers,

builders and contractors filled the aisles. Manufacturers and service offerers of ener-

gy efficient products, water conservation and carbon footprint-reducing mechanisms

were on hand to show off their wares. Throw in a big-name keynote draw — Colin

Powell — and you have a recipe for success. Past show attendance numbers have

proven the show to be a success, and although this year’s numbers are still being

processed, the exhibitors at the show that I spoke with were pleased with the turnout

and target audience. Make sure you catch the Greenbuild show next October 4-7 in

Toronto.

Breaking down LEED green

During the last 10 years or so, the green movement has been one of the hottest top-

ics, culminating into a multi-billion dollar industry in and of itself. But with success

comes imitation, and what is now widely-known as the oversaturation of “green” in

the marketplace. How do you truly know what is green and what isn’t? What govern-

ing body, or bodies, are legislating over this? There are organizations such as EPA’s

WaterSense and ENERGY STAR to provide guidelines on energy efficiency and water

conservation, for example. But perhaps the largest group, and most relative to a

plumbing engineer’s specs for a more efficient structure, is the U.S. Green Building

Council and its LEED accredited program. In fact, recently, the total footprint of com-

mercial projects certified under the USGBC’s LEED Green Building Rating System

surpassed one billion square feet. Another six billion square feet of projects are regis-

tered and currently working toward LEED certification around the world.

“This achievement demonstrates the transformation of the way we design, build

and operate buildings,” said Rick Fedrizzi, president, CEO and founding chair,

USGBC. “Not only does green building contribute to saving energy, water and

money; it also creates green jobs that will grow and energize our economy.”

The milestone is a testament to the global effort to meet USGBC’s vision that

buildings and communities will regenerate and sustain the health and vitality of all

life within this generation. LEED is the preeminent program for the design, con-

struction and operation of high-performance green buildings.

“The impact of these one billion square feet can be seen in communities

around the world,” said Peter Templeton, president of the Green Building

Certification Institute, the certifying body for LEED projects. “The use of LEED

represents a growing global commitment to improving our built environment for

future generations.”

Since it was first introduced to the marketplace in 2000, more than 36,000 com-

mercial projects and 38,000 single-family homes have participated in LEED. By

consuming less energy, LEED-certified buildings save money for families, busi-

nesses and taxpayers, reduce greenhouse gas emissions and contribute to healthier

environments for residents, workers and the community. n

Editorial, Advertising,Production, Accounting and

Administrative Offices

1838 Techny Ct.Northbrook, IL 60062

(847) 564-1127 • Fax: (847) 564-1264E-mail: [email protected]

OwnerTom M. Brown

Editorial & Production StaffJohn Mesenbrink, Editorial DirectorMarilyn Cunningham, Associate EditorCate C. Brown, Production ManagerMark Bruno, Art Director/Prepress

ContributorsTimothy Allinson, P.E., Designer’s Guide

Sam Dannaway, Fire ProtectionRon George, CPD, Code UpdateDan Holohan, Heating Help

Bob “Hot Rod” Rohr, Green SystemsBristol Stickney, Solar Solutions

Sales StaffBrad Burnside, Publisher East1838 Techny Court, Northbrook, IL60062 Phone: 847/564-1127 Cell: 224/659-3984Fax: 847/564-1264E-mail: [email protected]

David Schulte Midwest, South and E. Canada1838 Techny Court, Northbrook, IL 60062Phone: 847/564-1127 Cell: 847/420-4686Fax: 847/564-1264E-mail: [email protected]

Diane Spangler West, Texas and W. CanadaPO Box 9802, Fountain Valley, CA92728 Phone: 714/839-6700Fax: 714/839-6777E-mail: [email protected]

Moving past the patchouli — the progress of efficient systems

Editor’s Letter

Page 6/Plumbing Engineer December 2010

PLUMBING ENGINEER(USPS 567-950) ISSN 0192-1711

PLUMBING ENGINEER (USPS 567-950) ISSN 0192-1711 is published monthly by TMB Publishing Inc., 2165 ShermerRd., Suite A, Northbrook, IL 60062. Phone (847) 564-1127, Fax (847) 564-1264. Magazine is free to those who design andspecify plumbing/piping systems in commercial, industrial, institutional and governmental buildings; as well as governmentofficials and plumbing inspectors. Subscription rates for U.S. and Canada: $50 for one year, $90 for two years. Other coun-tries: $300 per year. Periodical postage paid at Northbrook, IL, and additional mailing offices. POSTMASTER: Change ofaddress should be sent to Plumbing Engineer, 440 Quadrangle Dr., Suite E., Bolingbrook, IL 60440. Material and opin-ions contained in contributed articles are the responsibility of the authors, not of TMB Publishing Inc., Plumbing Engineermagazine or its Editorial Advisory Board. The publisher cannot assume responsibility for any claims made by advertisers.Copyright © 2010 TMB Publishing Inc. All rights reserved. Volume 38, Number 12. Plumbing Engineer is microfilmed byUniversity Microfilms, Ann Arbor, MI, and indexed by Engineering Index Inc. Publications Mail Agreement No. 41499518.Return Undeliverable Canadian Addresses to PO Box 503, RPO West Beaver Creek, Richmond Hill ON L4B 4R6

John Mesenbrink, editorial [email protected]

pe12_pgs_06_07rev_Layout 1 12/1/10 7:27 AM Page 6

Page 7: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Something’s happening here

Leonard’s New Building Management System Interface Knows

Because you need real-time, accurate temperature monitoring to know whensomething is amiss…integrating Leonard’s newBuilding Management SystemInterface gives you everythingyou need. Providing you exactlywhat you want: real-timemonitoring of outputtemperature.

Through the use of an Ethernetconnection with integratedbuilding management software,BMSI gives real-time, accuratereadings to monitor temperedwater to the domestic hot watersystem. Integrate BMSI withinstalled mixing valves orintegrate with a complete watertemperature control system, for significant cost savings.

• Interface with buildingmanagement system

• Constant, real-time monitoringof output water temperature

• Simplifies maintenanceprotocol

• MODBUS TCP/IP protocol• Digital display

Leonard’s valves give “integratedcontrol” for all water temperingdesign needs. Before your next project, be sure to visitwww.leonardvalve.com or callour free technical support hotlineat 888-797-4456.

Integrated control with everyvalve from the leader intemperature valves, Leonard Valve.

NEW

Leonard...the right mix.

Circle 4 on Reader Reply Form on page 49

pe12_pgs_06_07rev_Layout 1 12/1/10 8:39 AM Page 7

Page 8: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Page 8/Plumbing Engineer December 2010

Industry News

WesTPORT, CONN. — solar products, trends and tech-nologies and their role in the HVAC/R marketplace willtake center stage at the 2011 AHR expo in Las Vegas,January 31 – February 2.

in addition to many new solar products on display,there will be more than a dozen seminars focused onsolar topics, as well as demonstrations of solar technolo-gy, provided throughout the three days of the world’slargest HVAC/R exposition and conference.

“solar is one of the fastest-growing segments of themany sustainable technologies featured at the show,”said Clay stevens, president of international expositionCompany, which produces and manages the AHReXPO. “At least 54 companies we know of will be fea-

Solar to shine at 2011 AHR Expo

More Industry News on page 10

turing solar products. AsHRAe and other leading indus-

try organizations have created special solar educational

sessions for AHR expo, and the UA Green Trailer will be

providing ongoing solar demonstrations.”

On the educational front, AsHRAe will be offering 10

solar-focused sessions, ranging from a forum on “The

Role of solar and Other Renewable energy sources in

strategic energy Planning” to several seminars on such

topics as integrating solar and Hydronic Heating for

Residential and small Commercial systems. in addition,

the international energy Agency (ieA) will be conduct-

ing a solar Cooling Workshop. For more information regarding the AHR expo in Las

Vegas, visit www.ahrexpo.com.

Liberty Pumps held its annual rep council meeting in con-junction with the ASPE show in Philadelphia. Councilmembers include: Front row – Charlie Fletcher of DelcoSales in Calif., Nev. and Hawaii; Scott Cooper of CooperNew England Sales in Conn. and N.H.; Steve Sutter ofHodes & Sutter Inc. in Mo.Back row – Randy Waldron, VP of sales/marketing,

Liberty Pumps; Charlie Pongratz of GT Gordon &Associates in Wash.; Tony Bruno of Triumph Sales in Pa.;Charlie Cook, president of Liberty Pumps.Not pictured – Chuck Schwabe, national sales manager,Liberty Pumps.

ECR International, National Grid and SunyCollege of Environmental Science and Forestryannounce partnership

UTiCA, N.Y. — eCR international™, a designer and man-ufacturer of hydronic and HVAC equipment, announcedits partnership with National Grid and the state Universityof New York College of environmental science andForestry (sUNY-esF) to install a freewatt® plus homeenergy system into the sUNY-esF College Residence,home to College President Cornelius B. Murphy, Jr.

The announcement was made at a news conference onTuesday, Nov. 9, at the College Residence near the sUNY-esF campus. Halco Plumbing & Heating, based out ofPhelps, N.Y., installed the system. installation of freewattplus was driven by the sUNY-esF Climate Action Plan.

“We are pursuing a variety of sustainable energy tech-nologies as part of theCollege’s efforts tobecome carbon neutralby 2015,” said MichaelKelleher, sUNY-esFdirector of renewableenergy systems. TheClimate Action Planuses a combination ofrenewable energy pro-jects, sustainable con-struction, energy con-servation and managedforestland to achievethe carbon neutral goal.“eCR is excited to helpsUNY-esF achieve itssustainability goals,”said Mike Paparone,eCR president andCeO. “By installing the

freewatt plus system, the home’s annual environmentalimpact can be reduced by up to 6,000 pounds or more ofgreenhouse gases.”

Liberty Pumps holds annual rep meeting at ASPE

NFPA Conference & Expo to participate in U. S. DOC program

LisLe, iLL. — The 2011 NFPA Conference & expo hasbeen selected to participate in the U.s. Department ofCommerce’s (DOC) international Buyer Program, whichbrings together international buyers and U.s. firms bypromoting leading U.s. trade shows in industries withsignificant export potential. The program is designed toassist exhibiting companies whose goal is to sell in the

pe12_pgs_08_13rev_Layout 1 11/30/10 11:02 AM Page 8

Page 9: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Circle 5 on Reader Reply Form on page 49

Page 10: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Industry News

Page 10/Plumbing Engineer December 2010

global marketplace. As a participant, nFPA Conference & Expo will be pro-

moted around the world through U.S. Commercial Serviceoffices, and U.S. trade specialists will recruit and leadbuyer delegations to the event.

“This program will expand the global reach of our eventand effectively energize teams of trade promotion special-ists into bringing qualified buyers and potential channel orJV partners to the show floor,” said Marc rosenstock, man-aging director of rOC-nFPA LLC, the event producer.

As part of the program, an on-site international businesscenter will provide export counseling, market analysis andmatchmaking services by country and industry expertsfrom the U.S. Commercial Service.

St. Louis City residential redevelopment project breaks ground

ST. LOUIS — Silver-plated shovels were plunged into theground on October 15 to commemorate the start of con-struction on north St. Louis City’s $41 million ArlingtonGrove residential redevelopment project. The ArlingtonGrove project symbolizes a much-needed revitalizationfor the neighborhood. Many individuals and organizationsare involved in the project, including the following:Friendly Temple Church, neighborhood residents, driven

More Industry News on page 12

Circle 6 on Reader Reply Form on page 49

Continued from page 8

alderman Jeffrey Boyd, developer McCormack BaronSalazar, KAI Design & Build (serving as the architect,M/E/P engineer, general contractor and building informa-tion modeling coordinator on the project), the City of St.Louis, the Associated General Contractors of St. Louisand the St. Louis Housing Authority. Thanks to theirefforts, positive change is just around the corner.

Plans for the area include 112 mixed-finance, mixed-income rental units in garden apartments, townhouses,semi-detached housing, a new mixed-use building andrehabilitation of the historic Arlington Elementary Schoolfor a total gross residential square footage of 162,000 and5,000 square feet of commercial/retail.

Environmentally friendly features incorporated into thedevelopment’s design and construction include Energy-Star labeled and water-conserving appliances and fixtures,solar panels, water management techniques during con-struction, high-efficiency HVAC systems, recycling ofcontent materials and reduction of heat-island effectthrough highly reflective roof shingles and perviouspaving. Construction on the project is expected to be com-pleted in spring 2012.

Grundfos to establish global competency center

OLATHE, KAn. — Grundfos Pumps Corp. recentlyannounced that it would create a new global businessdevelopment “competency center” devoted to the residen-tial groundwater market at their north American headquar-ters in Kansas. Establishing this competency center com-plements the global production relocation to northAmerica of the Grundfos Groundwater products, sub-mersible motors (MS402) and the award winning sub-mersible products (SQ/SQE/SQ Flex). Grundfos sub-mersible pumps (SP) are already produced in Fresno, Calif.

The competency center will concentrate on businessdevelopment and product development, which until now hadbeen located at the parent company’s worldwide headquar-ters in Bjerringbro, Denmark. In addition, Grundfos willlook to add additional engineering and business develop-ment resources for the submersible pump lines in Kansas.

IAPMO R&T designated certificationbody for ENERGY STAR

OnTArIO, CALIF. — IAPMO r&T, one of north America’spremier product certification agencies, is now an EPA-rec-ognized certification body to the EnErGY STAr® prod-uct labeling system. A joint program of the U.S.Environmental Protection Agency and the U.S. Departmentof Energy, EnErGY STAr-qualified products help con-

pe12_pgs_08_13rev_Layout 1 11/30/10 11:02 AM Page 10

Page 11: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

In the past, compliant and substandard couplings looked very similar.Now NSF® Certification makes it easy to tell the difference.

NSF-Certified couplings meet all industry standards.The NSF mark is proof of full compliance.

Anaco’s legendary quality is verified.

Standing the test of time

Circle 7 on Reader Reply Form on page 49

pe12_pgs_08_13rev_Layout 1 11/30/10 11:02 AM Page 11

Page 12: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Circle 8 on Reader Reply Form on page 49

The company’s Ohio facility is estimated to be the largestproducer of sanitary ware in the United States, manufactur-ing more than two million pieces each year.

Mansfield president Jim Morando welcomed the groupand gave a company overview before attendees toured thefacility. A working lunch followed, during whichMansfield’s marketing department presented the company’scommercial-product offering.

Lochinvar mourns death

lEBANON TENN. — Bruce Morgan, district sales managerfor lochinvar Corporation in the western Michigan terri-tory, passed away unexpectedly onNovember 2, 2010, while attendingan ETNA Supply event. An integralmember of the lochinvar familysince 2006, Bruce received thecompany's prestigious Salesman ofthe Year Award in 2008 and wasrecognized for Outstanding SalesAchievement in 2007 and 2009.

Bruce began his career in theindustry in 1972, earning his masterplumbers license, working as amechanical contractor and owninghis own business, Flagel & Morgan, from 1978 to 2006.Upon joining the lochinvar team, Bruce brought with himan extensive knowledge of all things related to boilers,water heaters, hydronics and plumbing.

sumers save money and protect the environment throughenergy efficient products and practices.

Manufacturers wishing to promote the energy savingbenefits of their products by labeling them as ENERGYSTAR-qualified can apply to do so now through IAPMOR&T, long recognized as a leader in third-party certificationfor its efficiency and commitment to customer service.

On January 1, 2011, qualifying manufacturers will be ableto display their IAPMO R&T certified ENERGY STARqualification for the following products:

• Appliances (clothes washers, dishwashers, water cool-ers, refrigerators and freezers);

• HVAC equipment (boilers, room air conditioners, cen-tral air conditioners and air source heat pumps, residentialwater heaters, furnaces, residential ceiling fans and residen-tial ventilating fans);

• Commercial food equipment (dishwashers, fryers, grid-dles, hot food holding cabinets, ice machines, ovens, refrig-erators, freezers and steam cookers);

• Battery charging systems (BCSs); and • Roof products.

Mansfield Plumbing hosts plumbing engineers

PERRYSVIllE, OHIO — In October, Mansfield PlumbingProducts invited plumbing engineers and contractors fromacross the state to spend a day at its Perrysville, Ohio, plant.

Page 12/Plumbing Engineer December 2010

Industry NewsContinued from page 10

pe12_pgs_08_13rev_Layout 1 11/30/10 11:02 AM Page 12

Page 13: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Introducing a bathroom that not only complements your customer’s lifestyle, but their desire for innovative technology as well. Welcome to style that works better TM for you.

www.americanstandard.comLook for this labelcertifying water-savingproducts that perform.

Proud to support The NatureConservancy’s freshwaterconservation efforts with $1 millionin funding through January 2012.

© 2010 AS America, Inc. Circle 9 on Reader Reply Form on page 49

pe12_pgs_08_13rev_Layout 1 11/30/10 11:02 AM Page 13

Page 14: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Page 14/Plumbing Engineer December 2010

The other day I got a call from Peggy, a woman whofound my name by searching the Internet about thesubject of hot water circulation. She e-mailed and

then called to discuss her domestic water woes in hernewly renovated home.

Problem No. 1 was her concern over varying hot watertemperatures at different fixtures in her home, specifical-ly, at the master bath versus at the kitchen sink. The waterat the master bath was noticeably hotter than that in thekitchen.

To help me understand the problem, Peggy describedher hot water system. She had a repiped circulated system

that ran water supply through the attic to the second floorfixtures and then dropped downstairs to feed the kitchen,prior to returning to the water heater. Note that the origi-nal piping system was run underground, as is very com-mon in housing tracts here in So Cal, with distribution inwalls up to the fixtures. This old abandoned system hadbeen prone to slab (underground pipe) leaks, hence therepipe.

Peggy’s system had a circulation pump on the hot waterreturn, but she found that the system would circulate nat-urally, even with the pump off, due to the fact that hotwater rises as colder water sinks. She preferred this natur-al circulation to running the pump, but she found that,with the pump off, the hot water upstairs became exces-sively hot.

I explained the concept of water heater stratificationand the fact that, without the pump on, the top of theheater would get hotter and the bottom relatively colder,as the thermostat was fooled by minimal water movement.This stratification was probably exaggerated by the factthe heater was at least 12 years old and there was surely

calcification at the bottom of the tank. Peggy agreed that,with the pump running, the hot water was more uniform,but this still didn’t resolve the issue of cooler water in herkitchen.

She asked whether it was bad practice to supply thekitchen from the tail end of the return line: I told her no,that shouldn’t make a difference. I explained that the newkitchen faucet might have a temperature-limiting stop thatcould be improperly set, allowing too much cold water toblend with the hot. Peggy said that she had read about thisand had tried turning off the cold water below the sink, butthat hadn’t helped. Clearly she was a diligent and proac-tive woman.

Next, I asked whether the remodeled shower had a sep-arate volume and temperature control with a diverter for ahand shower. She said that it did, so I explained that someshower valves were capable of creating a cross connectionif the diverter is used to shut off the water while the vol-ume control remains open. This cross connection wouldallow a blend of hot and cold water to pass through thevalve to the water circulation line. Peggy said that shewould investigate this but then mentioned an even moreimportant issue — the circulation line had no check valveafter the pump. She asked whether this could cause a prob-lem. I told her that it certainly could.

Figure 1 shows the basics of Peggy’s hot water system.Note the absence of a checkvalve after the circ pump.You can see that hot waterfor the kitchen would likelyflow in reverse from thewater heater to the kitchen,especially with the pump notrunning, since this is the pathof least resistance. Thismeans that the kitchen wouldreceive colder water from thebottom of the heater, plus atepid bypass from the coldwater make-up to the heater.

In Figure 2 you can see that, in this arrangement, withno check valve and the circ pump off, the kitchen wouldreceive almost entirely cold water directly from the coldwater supply to the heater. With the circ pump running,hot water would be more likely to come from the circulat-ed supply rather than from the water heater make-up, dueto the pressure from the pump. Peggy is going to have thisproblem corrected by adding a check valve after the circpump. She also plans to replace her old water heater.

Problem No. 2 was a bit more unusual. As stated,Peggy’s original installation had cold water piping locatedunderground. The repipe had cold water in the attic. Whenthis was first installed, in the winter, there were no prob-lems. Come summertime, Peggy found that the cold water

Unexpected problems

Designer’s GuideTimothy Allinson, P.E., Murray Co., Long Beach, Calif.

Continued on page 16

pe12_pgs_14_19rev_Layout 1 11/30/10 11:08 AM Page 14

Page 15: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

WOODFORD MANUFACTURING COMPANY

Zero or even below, the Woodford 65/67 seriescommercial wall hydrants will tolerate anytemperatures without freezing. All drainautomatically, even with a hose attached. The 67models include an ASSE Standard 1052 approvedbackflow preventer connection…and all come withWoodford quality, durability, and the ability totolerate anything Mother Nature can throw at them.

Model 67 Freezeless Wall Hydrantwith backflow preventionThe ASSE 1052 approved doublecheck is field testable. Designed tocomplement modern architecture.The Model 65 offers the samefeatures with an ASSE 1019 vacuum breaker.

B67 Freezeless Wall Hydrant withdouble check backflow protectionA rectangular version of our RB67,with backflow prevention. Alsooffered as the B65.

Choose from backflow prevention (67 series) or anti-siphon vacuum

breaker (65 series) hose connections.

RB67 Round BoxFreezeless Wall HydrantFits through standard 6"

diameter cored hole.Supplied with a ASSE

1052 approved doublecheck backflow

preventer that is fieldtestable. Designed

especially for tilt-upwall construction. Also

available as the RB65with ASSE 1019

approved vacuum breaker.

2121 Waynoka RoadColorado Springs, CO 80915800.621.6032www.woodfordmfg.com

WOODFORD 65/67 SERIES FREEZELESS WALL HYDRANTS

6

Circle 10 on Reader Reply Form on page 49

pe12_pgs_14_19rev_Layout 1 11/30/10 11:08 AM Page 15

Page 16: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Circle 11 on Reader Reply Form on page 49

Page 16/Plumbing Engineer December 2010

would run hot, at around 115 F, formany minutes before it cooled downto a more typical So Cal 60 degrees.

This was an unanticipated problemcaused by the cold water piping beingin the attic. The attic itself is abovethe second floor ceiling insulation, sothe temperature may easily rise to115 F during a summer day. Ofcourse, with the space at that temper-

ature, the cold water temperature willalso rise during periods of no use. So,instead of waiting for hot water toarrive at her sink or shower, Peggyhas to run water and wait for coldwater to arrive; water cool enough toshower or drink or wash vegetables.Quite ironic, actually, because this isthe reverse of the stereotypical hotwater delivery problem.

So, would I have thought of theseproblems and avoided them?Possibly not. The use of a checkvalve in a single loop hot water circu-lation system is traditional, but Ithink check valves in HWC systemsare frequently overused. In this case,however, due to the tepid water back-feed, the necessity for a check valvewas crucial. And would I havethought about the heat in the atticwarming up the cold water? Probablynot. The ideal place to run the coldwater piping would be through thejoists of the second floor construc-

tion, but, with an existing home, it ismuch easier to put the pipes in theattic. It’s always easier to learn theselessons from others’ mistakes, with-out having to learn them firsthand. n

Timothy Allinson is a senior pro-fessional engineer with Murray Co.,Mechanical Contractors, in LongBeach, Calif. He holds a BSME fromTufts University and an MBA fromNew York University. He is a profes-sional engineer licensed in bothmechanical and fire protection engi-neering in various states, and is aLEED accredited professional.Allinson is a past president of ASPE,both the New York and OrangeCounty Chapters. He can be reachedat [email protected].

Continued from page 14

The views and opinions expressed in thiscolumn are those of the author and do notreflect those of Plumbing Engineer nor itspublisher, TMB Publishing.

Designer’s Guide

Problem No. 1 was her concern over varying hotwater temperatures at different fixtures in her

home, specifically, at the master bath versus

at the kitchen sink.

pe12_pgs_14_19rev_Layout 1 11/30/10 11:08 AM Page 16

Page 17: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Circle 12 on Reader Reply Form on page 49

pe12_pgs_14_19rev_Layout 1 12/1/10 8:39 AM Page 17

Page 18: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

pe12_pgs_14_19rev_Layout 1 12/1/10 8:40 AM Page 18

Page 19: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Circle 13 on Reader Reply Form on page 49

pe12_pgs_14_19rev_Layout 1 12/1/10 8:40 AM Page 19

Page 20: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Ron George, CPDPresident, Ron George Design & Consulting Services

Code Classroom

Fuel gas codes address dangers associated with purging of fuel gas pipes

The NFPA, through an emergency revision to the NFPA2009 code, prohibited the use of natural gas to purge gaspipelines. This prohibition is a result of the explosion andfire at the Kleen Energy power plant. The Chemical SafetyBoard concluded that the purging, or blowing-out ofdebris, from the natural gas piping system, using naturalgas instead of an inert gas, led to the accident inConnecticut. In view of these findings, the CSB appealedto standards and regulatory bodies such as OSHA, AGA,ICC, IAPMO and NFPA to amend the codes that regulatenatural gas piping and operations.

The fuel gas safety codes require that new piping instal-lations be pressure-tested with air or an inert gas such asnitrogen or carbon dioxide prior to being placed into oper-ation. The inert gas is required for pressure testingbecause, if there is a leak, it could cause an explosion orfire. The inert gas pressure test requires purging of the gasmains during the introduction of natural gas in order tostart up the mechanical equipment. Purging is commonlydone by one of two methods: fuel gas is used to directlydisplace the air or inert gas is used to displace the air andthen fuel gas is used to displace the inert gas.

During their investigation of one of the incidents, theCSB discovered serious dangers that can arise during fuelgas purging operations; they highlighted some key issuesthat the agency recommends for improving safety in theworkplace.

Purging new or existing gas piping into buildings canbe highly hazardous due to the possible accumulation ofgas above the lower explosive limit (LEL) and the associ-ated danger of fire and explosion. LEL, also known as thelower flammable limit (LFL), is defined as “that concen-tration of a combustible material in air below which igni-tion will not occur.” See the NFPA document titled,“Recommended Practice for Handling Releases ofFlammable and Combustible Liquids and Gases, NFPA329 (2005).

Purged gases should always be directed to a safe loca-tion outdoors, away from people and ignition sources.This can be done using either a temporary hose or pipingor permanently installed vent pipes, depending on thefacility design. Hoses should be grounded so that theflow of gas in a vinyl, plastic or rubber hose does notbuild up a static electricity charge that could be a sourceof ignition.

Purging indoors should only be done in limited circum-stances, where purging outdoors is not possible. In suchcases, all non-essential personnel should be evacuatedfrom the area, well away from a possible blast zone; allignition sources should be controlled or eliminated, eventhose significantly downwind of the discharge location

On June 9, 2009, a ConAgra food production facili-ty in Garner, North Carolina, experienced a cata-strophic natural gas explosion that caused four

deaths, three critical life-threatening burn injuries, anamputation and other injuries that sent a total of 67 peopleto the hospital.

The explosion caused serious structural damage to theapproximately 87,000-square-foot packaging and ware-house area of the Garner plant, including wall and roofcollapse, which caused the deaths and serious injuries.37% of the roof area experienced collapse and 60% eithercollapsed or was so heavily damaged that it was unstable.

Following extensive testimony and public comment,the U. S. Chemical Safety Board, the agency investigatingthis incident, approved urgent safety recommendations ongas purging safety at a public meeting in Raleigh, NorthCarolina. The recommendations, which were approved aspresented by the staff, urged the National Fire ProtectionAssociation (NFPA), the American Gas Association(AGA) and the International Code Council (ICC) tostrengthen the model fuel gas code provisions on the purg-ing of fuel gas piping systems.

Following is a partial list of recent fuel gas explosionsrelated to purging operations that have led to multipleinjuries and deaths:

— 1997. Explosion at a fitness center in Cary, N.C,severely burned two people and injured four others.

— 2005. Explosion and fire at a Triumph Food facilityin St. Joseph, Mo., killed one worker and injured 19 others.

— 2005. Explosion and fire in a school in Porterville,Calif., burned two plumbers.

— 2007. Explosion at a hotel in Cheyenne, Wyo.,severely burned two plumbers.

— 2008. Explosion and fire at the San Diego Hiltonhotel injured 14 workers, several of them critically.

— 2009. Explosion and fire at a ConAgra Food facilityin Garner, N.C., killed five and seriously injured 67.

— 2010. Explosion and fire killed five and seriouslyinjured 27 at a Kleen Energy power plant in Middletown,Conn.

When new fuel gas piping is put into service, or whenexisting piping is returned to service after a long serviceinterruption, it is typically necessary to purge the lines of air.

These explosions all occurred when workers were purg-ing fuel gas lines during construction.

The NFPA develops widely recognized consensus fireprotection codes and standards. Another family of build-ing codes is published by the International Code Council(ICC) and includes the 2009 International Fuel Gas Code(IFGC). Both codes address some safety guidance andrequirements for the installation and operation of fuel gaspiping and equipment, but there is room for improvement.

Page 20/Plumbing Engineer December 2010

Continued on page 22

pe12_pgs_20_27rev_Layout 1 11/30/10 11:11 AM Page 20

Page 21: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Introducing our 2d and 3d CAD Library

Simplify your building modeling process. We have the industry

standard 2d and 3d CAD files you’re looking for including:

Revit, DWF, ACIS, STEP, DWG and more. Files are available for our

popular water safety & flow control, backflow prevention and drain-

age product lines with more becoming available every day.

Go to watts.com/CAD to download today. How’s that for simple!

Add Depth to Your Project

Introducing our 2d and 3d CAD Library

A Watts Water Technologies Company

Available in

at watts.com

Available in

Circle 14 on Reader Reply Form on page 49

pe12_pgs_20_27rev_Layout 1 11/30/10 11:11 AM Page 21

Page 22: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Page 22/Plumbing Engineer December 2010

Code Classroom

and ventilation should be adequate enough to maintain thegas concentration well below the LEL at all times.

Workers should never rely on their sense of smell todetect releases of fuel gases. Although an odorant is typi-cally added to fuel gases to warn workers and consumersof releases, the perception of odor is highly subjective andvaries from one person to another. People also becomedesensitized to odor during prolonged exposures. New gaspipes and containers can condense the odorant out of thefuel gas, especially if the new gas is allowed to sit in thepipe for a long period of time before use and if the pipinggoes through daily temperature changes. The pipe wallswill continue to absorb the odorant until they become sat-urated This creates a condition known as “odor fade.”Odor fade is also common in new piping systems whenthe new piping is not saturated or pickled with odorant.

Plumbing and mechanical trade schools, contractors,utility companies and large facility owners should includetraining on the problem of odor fade in new gas pipingsystems.

Combustible gas detectors should always be used tomonitor the gas concentration exiting the purge hose dur-ing purging operations. To provide the most accurateinformation about combustible gas levels, samplingshould be conducted continuously at the discharge loca-tion. Personnel involved in gas purging operations shouldbe fully trained and knowledgeable about safe gas ventingpractices, and they should be properly trained in the use ofthe gas detectors.

The 2009 edition of the National Fuel Gas Code, NFPA54, ANSI Z223.1 Chapter 54-15 defines a piping purge as“to free a gas conduit of air or gas, or a mixture of gasand air.” The 2009 National Fuel Gas Code and the 2006International Fuel Gas Code both require that pipingbeyond specified lengths be purged with an inert gasbased upon the nominal pipe size.

In jurisdictions where the NFPA 54 National Fuel GasCode is adopted it applies to the installation of fuel gaspiping systems, appliances, equipment and related acces-sories. This code addresses the following issues:

• Coverage of piping systems shall extend from thepoint of delivery to the appliance connections. For otherthan undiluted liquefied petroleum gas (LP-Gas) systems,the point of delivery shall be considered to be the outlet ofthe service meter assembly or the outlet of the service reg-ulator or the service shutoff valve where no meter is pro-vided. For undiluted LP-Gas, the point of delivery shall beconsidered to be the outlet of the final pressure regulator,exclusive of line gas regulators, in the system. The maxi-mum operating pressure shall be 125 psi (862 kPa).

Exception No. 1: Piping systems for gas — air mixtureswithin the flammable range are limited to a maximumpressure of 10 psi (69 kPa).

Exception No. 2: LP-Gas piping systems are limited to20 psi (140 kPa), except as provided in 5.5.2.

• Requirements for piping systems shall include design,materials, components, fabrication, assembly, installation,testing, inspection, operation and maintenance.

• Requirements for appliances, equipment, and relatedaccessories shall include installation, combustion and ven-

tilation air and venting. Tentative Interim Amendment addresses purgingIn response to the explosions mentioned earlier, a

Tentative Interim Amendment, TIA 09-3 (SC 10-8-22/TIALog #984R) was processed by the NFPA 54 TechnicalCommittee on the National Fuel Gas Code and issued bythe NFPA Standards Council in August 2010. TheUniform Plumbing Code and the Uniform MechanicalCode technical committees also recently discussed TIAsaddressing new safety requirements for purging opera-tions with indoor fuel gas piping systems, and we areawaiting the outcome of their review.

A TIA is tentative because it has not been processedthrough the entire standards-making procedures and inter-im because it is effective only between editions of thestandard. A TIA automatically becomes a proposal for thenext edition of the standard; as such, it then is subject toall of the procedures of the standards-making process.

The NFPA’s August 2010 TIA called for the followingrevisions to NFPA 54, Section 8.3. (There is supplementalinformation in the appendix for items with an asterisk*.)

8.3* Purging requirements. The purging of pipingshall be in accordance with 8.3.1 through 8.3.3.

8.3.1* Piping systems required to be purged out-

doors. The purging of piping systems shall be in accor-dance with the provisions of 8.3.1.1 through 8.3.1.4 wherethe piping system meets either of the following:

1. The design operating gas pressure is greater than 2psig (14 kPa).

2. The piping being purged contains one or more sec-tions of pipe or tubing greater than 2 in. and exceeding thelengths in Table 8.3.1.1.

8.3.1.1 Removal from service. Where existing gas pip-ing is opened, the section that is opened shall be isolatedfrom the gas supply and the line pressure vented in accor-dance with 8.3.1.3. Where gas piping meeting the criteriaof Table 8.3.1.1 is removed from service, the residual fuelgas in the piping shall be displaced with an inert gas.

Table 8.3.1.1 Size and Length of PipingNominal Pipe Length ofSize (in.) Piping (ft)2 ½ > 503 > 304 > 156 > 108 or larger Any lengthFor SI units: 1 ft = 304.8 mm.

8.3.1.2* Placing in operation. Where gas piping con-taining air and meeting the criteria of Table 8.3.1.1 isplaced in operation, the air in the piping shall first be dis-placed with an inert gas. The inert gas shall then be dis-placed with fuel gas in accordance with 8.3.1.3.

8.3.1.3 Outdoor discharge of purged gases. Theopen end of a piping system being pressure vented orpurged shall discharge directly to an outdoor location.Purging operations shall comply with all of the follow-ing requirements:

Continued on page 24

Continued from page 20

pe12_pgs_20_27rev_Layout 1 11/30/10 11:11 AM Page 22

Page 23: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

INTRODUCING THE ACCELERA© 300 HEAT PUMP WATER HEATER:ACCELERATE YOUR SAVINGS!

SAVEENERGYWATERMONEY

The new Accelera® 300 can extract up to 80% of its energy requirements from the air around it. Heat pumps have been around for decades, but a heat pump water heater is a brand new concept. The Accelera® 300 works like an air conditioner - but instead of dumping the heat outdoors, it puts it into the water.

The Accelera’s compressor and fan consume only 1 kWh of electricity to generate the heat equivalent of 3 – 5 kWh. The efficiency of the unit goes up with increasing ambient air temperatures. This ground breaking efficiency redefines what a water heater is capable of, and what savings can really mean !

Energy from nature.

TOLL FREE 800.582.8423www.stiebel-eltron-usa.com

Simply the Best

New!

REDUCES HOT WATER COSTS BY UP TO 80 %

COOLS AND DEHUMIDIFIES THE AIR AROUND IT

LOW STAND-BY LOSSES THROUGH GOOD INSULATION

FEDERAL TAX CREDIT:SAVE 30% UP TO $1,500

OF THE TOTAL SYSTEM COST!

Circle 15 on Reader Reply Form on page 49

pe12_pgs_20_27rev_Layout 1 11/30/10 11:11 AM Page 23

Page 24: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Page 24/Plumbing Engineer December 2010

1. The point of discharge shall be controlled with ashutoff valve.

2. The point of discharge shall be located at least 10 ft(3 m) from sources of ignition, at least 10 ft (3 m) frombuilding openings and at least 25 ft (7.6 m) from mechan-ical air intake openings.

3. During discharge, the open point of discharge shallbe continuously attended and monitored with a com-bustible gas indicator that complies with 8.3.1.4.

4. Purging operations introducing fuel gas shall bestopped when 90% fuel gas by volume is detected withinthe pipe.

5. Persons not involved in the purging operations shallbe evacuated from all areas within 10 ft (3 m) of the pointof discharge.

8.3.1.4* Combustible gas indicator. The combustiblegas indicator used during purging operations shall be list-ed and shall be calibrated in accordance with the manu-facturer’s instructions and recommended schedule. Thecombustible gas indicator used for pipe discharge moni-toring shall numerically display a volume scale from 0%to 100% with a resolution of not greater than 1% incre-ments.

8.3.2* Piping systems allowed to be purged indoors

or outdoors. The purging of piping systems shall be inaccordance with the provisions of

8.3.2.1 where the piping system meets both of the fol-lowing:

1. The design operating pressure is 2 psig (14 kPa) orless.

2. The piping system being purged is constructed entire-ly from pipe or tubing of 2-in. nominal size or smaller, orlarger pipe or tubing with lengths shorter than specified inTable 8.3.1.1.

8.3.2.1* Purging procedure. The piping system shallbe purged in accordance with one or more of the following:

1. The piping shall be purged with fuel gas and shalldischarge to the outdoors.

2. The piping shall be purged with fuel gas and shalldischarge to the indoors or outdoors through an applianceburner not located in a combustion chamber. Such burnershall be provided with a continuous source of ignition.

3. The piping shall be purged with fuel gas and shalldischarge to the indoors or outdoors through a burner thathas a continuous source of ignition and that is designed forsuch purpose.

4. The piping shall be purged with fuel gas that is dis-charged to the indoors or outdoors, and the point of dis-charge shall be monitored with a listed combustible gasdetector in accordance with 8.3.2.2. Purging shall bestopped when fuel gas is detected.

5. The piping shall be purged by the gas supplier inaccordance with written procedures.

8.3.2.2 Combustible gas detector. The combustiblegas detector used during purging operations shall be listedand shall be calibrated or tested in accordance with themanufacturer’s instructions and recommended schedule.The combustible gas detector used for pipe dischargemonitoring shall indicate the presence of fuel gas.

8.3.3 Purging appliances and equipment. After the

piping system has been placed in operation, appliancesand equipment shall be purged before being placed intooperation.

Revise the Appendix “A” of NFPA 54 section A.8.3 toread as follows:

A.8.3 The process of purging gas piping of fuel gas orcharging gas piping that is full of air with fuel gas must beperformed in a manner that will minimize the potential fora flammable mixture to be developed within the piping.Also, a significant amount of flammable gas should not bereleased within a confined space. Natural gas and propanesuppliers add a distinctive odor to their gas to aid in itsdetection. However, when a new system is brought intoservice and un-odorized gas is detected, the company sup-plying the gas should be contacted to inform them of thesituation and to determine what action should be taken.

A.8.3.1 Paragraph 8.3.1 describes the characteristicsof gas piping systems that are required to be purged onlyto the outdoors. The criteria were selected to distinguishbetween piping systems located in industrial, large com-mercial and large multifamily buildings from those locat-ed in light commercial and smaller residential buildings.The gas piping systems installed in industrial, large com-mercial and large multifamily buildings are considered tobe larger more complex systems for the purposes of defin-

ing their purging requirements. Because of their largerpipe volumes or potential for higher flow rates, these sys-tems require procedures to ensure that large volumes offuel gases are not released indoors and that flammablemixtures do not occur within the piping itself. Installers ofthese complex systems deal with considerably more vari-ables that may result in a higher potential for discharge oflarge gas volumes during purging operations.

Specific occupancy categories such as industrial, man-ufacturing, commercial and large multifamily were notincluded in the fuel gas code. U.S. building codes definethese occupancies for the purpose of construction andsafety requirements. There is no general relation betweenthe occupancy types, as defined by the building codes, andthe size of gas piping system to be installed in that occu-pancy. The gas piping size and operating pressure arebased on the nature of the piping system and gas appli-ances to be installed and are not dependent upon a build-ing’s occupancy type or classification.

A.8.3.1.2 It is recommended that the oxygen levels inthe piping be monitored during the purging process todetermine when sufficient inert gas has been introduced.The manufacturer’s instructions for monitoring instru-

Continued on page 26

Code ClassroomContinued from page 22

When new fuel gas piping is put into service, or when existing piping is returned to serviceafter a long service interruption, it is typically

necessary to purge the lines of air.

pe12_pgs_20_27rev_Layout 1 11/30/10 11:12 AM Page 24

Page 25: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Circle 16 on Reader Reply Form on page 49

pe12_pgs_20_27rev_Layout 1 11/30/10 11:12 AM Page 25

Page 26: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Page 26/Plumbing Engineer December 2010

ments must be followed when performing purge opera-tions.

A.8.3.1.4 Combustible gas indicators are available withdifferent scales. For purging, it is necessary to use the per-cent gas in air scale and to follow the manufacturer’s oper-ating instructions. The % LEL scale should not be used, asit is not relevant to purging.

A.8.3.2 The criteria were selected to describe typicalgas piping systems located in light commercial and small-er residential family buildings. Gas piping systemsinstalled in these buildings are considered to be smallerand less complex systems for the purposes of definingtheir purging requirements. Installers have familiaritywith purging these systems and the potential for dischargeof large gas volumes during purging operations is low.Also see A.8.3.1.

A.8.3.2.1 Where small piping systems contain air andare purged to either the indoors or outdoors with fuel gas,a rapid and uninterrupted flow of fuel gas must be intro-duced into one end of the piping system and vented out ofthe other end so as to prevent the development of a com-bustible fuel/air mixture. Purging these systems can bedone either by using a source of ignition to ignite the fuelgas or by using a listed combustible gas indicator that candetect the presence of fuel gas.

Following is an excerpt from the 2009 InternationalFuel Gas Code text addressing purging of fuel gas pipingsystems:

406.7 Purging. Purging of piping shall comply withSections 406.7.1 through 406.7.4.

406.7.1 Removal from service. Where gas piping is tobe opened for servicing, addition or modification, the sec-tion to be worked on shall be turned off from the gas sup-ply at the nearest convenient point and the line pressurevented to the outdoors or to ventilated areas of sufficientsize to prevent accumulation of flammable mixtures. Theremaining gas in this section of pipe shall be displacedwith an inert gas as required by Table 406.7.1.

TABLE 406.7.1 — Length of Piping RequiringPurging with Inert Gas for Servicing or Modification

Nominal Pipe Size Length of Piping(inches) Requiring Purging

21/2 > 50 feet3 > 30 feet4 > 15 feet6 > 10 feet8 or larger Any length

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm.406.7.2 Placing in operation. Where piping full of air

is placed in operation, the air in the piping shall be dis-placed with fuel gas, except where such piping is requiredby Table 406.7.2 to be purged with an inert gas prior tointroduction of fuel gas. The air can be safely displacedwith fuel gas provided that a moderately rapid and contin-

uous flow of fuel gas is introduced at one end of the lineand air is vented out at the other end. The fuel gas flowshall be continued without interruption until the vented

gas is free of air. The point of discharge shall not be leftunattended during purging. After purging, the vent shallthen be closed. Where required by Table 406.7.2, the air inthe piping shall first be displaced with an inert gas, and theinert gas shall then be displaced with fuel gas.

TABLE 406.7.2 — Length of Piping RequiringPurging with Inert Gas Before Placing in Operation

Nominal Pipe Size Length of Piping(inches) Requiring Purging

3 > 30 feet4 > 15 feet6 > 10 feet8 or larger Any lengthFor SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm.

406.7.3 Discharge of purged gases. The open end ofpiping systems being purged shall not discharge into con-fined spaces or areas where there are sources of ignitionunless precautions are taken to perform this operation in asafe manner by ventilation of the space, control of purgingrate and elimination of all hazardous conditions.

406.7.4 Placing appliances and equipment in opera-

tion. After the piping system has been placed in operation,all appliances and equipment shall be purged and thenplaced in operation, as necessary.

These are very important issues that need to be taughtto the installing contractors in the trades to make sure thatthey are aware of the odor fade issues and the dangersassociated with purging operations. Combustible gasdetectors are going to be required for any contractor work-ing on a fuel gas system. Stay tuned for a flurry of codechange proposals on this subject during the next round ofcode hearings for the International codes, the uniformcodes and the NFPA 54 Fuel Gas Code. n

Ron George is president of Ron George Design &Consulting Services. He has served as Chairman of theInternational Residential Plumbing & Mechanical CodeCommittee. To contact Ron, write to him at [email protected].

Code ClassroomContinued from page 24

The views and opinions expressed in this column are those of the author anddo not reflect those of Plumbing Engineer nor its publisher, TMB Publishing.

Combustible gas detectors are going to be required for any contractor working

on a fuel gas system.

pe12_pgs_20_27rev_Layout 1 11/30/10 11:12 AM Page 26

Page 27: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Circle 17 on Reader Reply Form on page 49

pe12_pgs_20_27rev_Layout 1 11/30/10 11:12 AM Page 27

Page 28: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Samuel S. Dannaway, PE,President, S.S. Dannaway Associates, Inc., Honolulu

FPE Corner

Pressure regulation in standpipe and sprinkler systems

The need for concern about the use of pressure regu-lating devices in fire protection systems was high-lighted by a February 1991 fire at the One Meridian

Plaza in Philadelphia, Pa. The fire burned virtually uncon-trolled from the 22nd floor to the 29th floor, where it wasstopped by activation of 10 sprinklers installed on the 30thfloor. Three firefighters were killed in this high-rise fire.

The major contributing factor to the fire was the lack ofcomplete sprinkler protection, but another significant factorwas the inability of the fire service to obtain adequate pres-sure for hose streams due to improperly set pressure regu-lating standpipe hose valves. NFPA issued an Alert Bulletinin May 1991 requesting fire departments to check all sys-tems with pressure regulating devices. .

It is good fire protection practice to avoid the use of anypressure regulating devices in fire protection water sup-plies. Obviously, that is often not possible and, fortunately,NFPA standards dealing with water-based suppression sys-tems have incorporated requirements and guidance on theiruse. NFPA 13, as well as NFPA 14, 20 and 25 define a pres-sure regulating device as follows:

Pressure Regulating Device. A device designed for thepurpose of reducing, regulating, controlling, or restrictingwater pressure.

Pressure regulating devices include pressure restrictingdevices, pressure control valves, and pressure reducingdevices. NFPA 13 does not define these various subcate-gories of pressure regulating devices but one can find a def-inition for them in NFPA 14 as follows:

Pressure Restricting Device. A valve or devicedesigned for the purpose of reducing the downstream waterpressure under flowing (residual) conditions only.

Pressure Control Valve. A pilot-operated pressurereducing valve designed for the purpose of reducing thedownstream water pressure to a specific value under bothflowing (residual) and non-flowing (static) conditions.

Pressure Reducing Valve. A valve designed for the pur-pose of reducing the downstream water pressure under bothflowing (residual) and non-flowing (static) conditions.

From this set of definitions we conclude that there aretwo categories of pressure regulating devices, the pressurerestricting device and the pressure regulating valve. Thepressure control valve is a type of pressure regulating valve.

There appear to be no requirements related to pressurerestricting devices in NFPA 13, NFPA 14 or NFPA 20. Fromthis I conclude that pressure restricting devices may not beused.

Pressure Regulating Devices in Sprinkler Systems

(2010 edition of NFPA 13)

There are several areas in NFPA 13 that contain provi-sions that apply to pressure reducing valves. The generalrequirements are:

• A pressure reducing valve must be installed where nor-

Page 28/Plumbing Engineer December 2010

mal pressure conditions greater that 175 psi can exist. • Maximum outlet pressure must not exceed 165 psi.• Pressure gauges must be installed on the upstream and

downstream sides of each pressure reducing valve.• A minimum ½-inch relief valve must be installed on the

discharge site of the pressure reducing valve set to operateat 175 psi or less.

• Unless the pressure reducing valve has an integral list-ed indicating valve, one must be provided on the inlet side.

• There shall be provisions for flow testing downstreamof the pressure reducing valve at system demand.

NFPA 13 also requires that the inlet and outlet pressuresettings of pressure reducing valves be identified on sprin-kler system shop drawing submittals and that pressure loss-es through the valve must be included in hydraulic calcula-tions and based on normal pressure conditions. One wouldexpect that manufacturer’s data verifying these losses beprovided as part of the submittal package (This data isrequired by NFPA 14).

During sprinkler system acceptance, pressure reducingvalves must be tested at both flow and no-flow conditions.The standard does not state that the flow must be at systemdemand. The testing must confirm that the device properlyregulates at maximum inlet pressures as well as at normalinlet pressure. Test data must include static and residualpressures at inlet and outlet and flow rates. This data mustbe recorded on the Contractors Material and TestCertificate. (See Figure 24.1 of NFPA 13.)

Pressure Regulating Devices in Standpipe Systems

(2010 edition of NFPA 14)

The current edition of NFPA 14 introduces provisions forexpress mains, which are mains supplying higher standpipezones. These mains are permitted to have a maximumworking pressure exceeding 350 psi, provided that there arenot hose outlets on any part of the main where these pres-sures are exceeded. This is a helpful provision for thedesign of standpipes in very tall buildings in that it allowsdesigners to locate the high pressure pumping systems nearthe ground floor, avoiding the need for pumping up to a firepump at a higher zone. Pressure regulating devices may beused to avoid providing separate fire pumping in multiplezone systems if several conditions are met. These include:

• The PRD must be capable of isolation for maintenanceand repair. The fire department connection must tie into thesystem side of the PRD outlet isolation valve. A normally-closed bypass line shall be provided around each device.

• The system must be designed such that failure of a sin-gle PRD does not allow pressure to exceed 175 to morethan two hose valves. This provision will require thedesigner to put dual PRDs in series.

• The system must be supervised of high-pressure failureof the PRD in accordance with NFPA 72.

• Pressure gauges must be provided at the inlet and out-Continued on page 30

pe12_pgs_28_31rev_Layout 1 11/30/10 11:15 AM Page 28

Page 29: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Circle 18 on Reader Reply Form on page 49

pe12_pgs_28_31rev_Layout 1 11/30/10 11:15 AM Page 29

Page 30: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Page 30/Plumbing Engineer December 2010

FPE Corner

let of the PRD. Residual pressures for 1 ½-inch hose outlets are limited to

100 psi and, where static pressures exceed 175 psi on theinlet side, the static pressure must be limited to 100 psi.

To facilitate testing, each pressure regulating valve shallbe provided with a drain/test riser capable of handling aflow equal to the largest system demand. NFPA 14 containsfurther requirements for minimum diameters of thedrain/test riser. Drain riser inlets must be provided withswivel hose connections compatible with fire departmenthose. For acceptance testing of systems containing pressureregulating devices, all devices must be tested at designflows to verify that the device is operating and that inlet andoutlet pressures are correct.

Author’s request: If anyone out there has developed atest setup that can properly measure flows while doingthese tests, I would like to hear about it. This is somethingwe struggle with when acceptance testing systems.

The Contractor’s Material and Test Certificate forAboveground Piping form contained in chapter 11 of NFPA14 has a useful table for recording the pressure regulatingvalve test data.

Pressure Regulating Devices in Fire Pump Systems

(2010 edition of NFPA 20)

Briefly, NFPA 20 does not permit pressure regulatingdevices to be used to control maximum shutoff pressure tobelow system ratings. NFPA 20 further prohibits the use ofpressure regulating devices in the discharge pipe “except aspermitted” by NFPA 20. In an annex note it is clarified thatthis requirement is not intended to prohibit pressure regu-lating devices downstream of the fire pump dischargevalve. However, there is no actual permission to use thepressure regulating devices found in the body of the stan-dard. From this I gather that it is acceptable to use pressureregulating valves beyond the system discharge valve.

Pressure Regulating Devices in the 2011 edition of

NFPA 25

Chapter 13 of NFPA 25 contains requirements of inspec-tion and testing of pressure regulating devices. Of note isthat pressure regulating devices for sprinkler and standpipesystems must be full flow tested every five years and partialflow tested (just to check for operation) at least annually.Master pressure regulating devices, those installed to regu-late pressures in an entire fire protection system or stand-pipe zone, shall be full flow tested annually and partial flowtested quarterly.

Don’t let the bedbugs bite your fire sprinkler system:

dealing with bedbugs poses threat to sprinklers

Now on another note, I thought this item is interestingenough and important enough to include for our readers.From the National Fire Sprinkler Association E-tech AlertIssue Number: 194 issued November 16, 2010, Editor:Russell P. Fleming, PE.

A recent discussion topic at the website of the LosAngeles Area Fire Marshals’ Association was the possibledanger to sprinklers from the current national resurgence inbedbugs. One of the vendors of remediation efforts hadapproached the fire marshals asking whether there could beproblems in sprinklered occupancies when a room of infes-

tation is treated by heating it to 140 F for a period of fourhours.

The obvious answer is yes, there could be a problem.Table 6.2.5.1 of NFPA 13 (2010 edition) limits the use ofordinary temperature rated sprinklers to areas with maxi-mum ceiling temperatures of 100 F. Heat sources used toincrease room temperatures can create “hot spots” withtemperatures higher than the intended average. Even incases where the temperatures are never sufficient to activatethe sprinklers, the sprinklers can be damaged by the weak-ening of solder links or the stressing of glass bulbs throughrepeated bubble disappearance and reformation.

The vendor that approached the fire marshals groupnoted that their company policy is to drain the system, tem-porarily replace all ordinary rated sprinklers with high tem-perature rated sprinklers and then recharge the system priorto heating the room. Following the treatment, the originalsprinklers are put back in place. The vendor claimed to beput at a disadvantage, however, from competitors who weresimply installing insulated covers over the sprinklers orinstalling some type of ice-cooled covers during the treat-ment process.

The potential to damage sprinklers with temporary cov-erings is a concern. Even in the new allowance to cleansprinklers by means of compressed air or by a vacuum(A.5.2.1.1.2(5) in the 2011 edition), NFPA 25 is not intend-ing that equipment be allowed to actually touch the sprin-klers. The manufacturers of proposed temporary coversshould be encouraged to seek product listings that wouldaddress potential damage issues.

Are there applicable rules? NFPA 25 — Inspection,Testing and Maintenance of Water Based Fire ProtectionSystems, requires that sprinklers be free of foreign materialsand have sufficient clearance to equipment (Sections5.2.1.1.1 and 5.2.1.2 in the 2008 edition). The 2011 editionof NFPA 25 also makes the distinction between systemimpairments and lesser categories of critical and noncriticaldeficiencies. Annex E suggests that a violation of Section5.2.1.1.1, such as having foreign materials attached to orsuspended from sprinklers, rises to the level of impairment.This would be especially obvious if it involved sprinklersthroughout the premises.

Bedbug treatments involving planned impairmentswould be required to follow all of the provisions of Chapter15 of NFPA 25, including the assignment of an impairmentcoordinator. Special provisions would be applicable if arequired system is to be out of service for more than 10hours in a 24-hour period, such as building evacuation orestablishment of an approved fire watch. Special occupan-cies such as health care facilities may have their ownimpairments requirements. n

The investigation report and alert bulletin can beobtained by NFPA members at http://www.nfpa.org/catalog/services/customer/downloadmemberonlypdf.asp?pdf-name=fiphiladelphia%2Epdf&src=nfpa.

The views and opinions expressed in this column are those of the author anddo not reflect those of Plumbing Engineer nor its publisher, TMB Publishing.

Continued from page 28

pe12_pgs_28_31rev_Layout 1 11/30/10 11:15 AM Page 30

Page 31: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Circle 19 on Reader Reply Form on page 49

pe12_pgs_28_31rev_Layout 1 11/30/10 11:15 AM Page 31

Page 32: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Page 32/Plumbing Engineer December 2010

Business was off, but you know that already. Justabout everyone made less money, but we all madeless money together, so it’s relative. Oh, and we’re

all still here. We had more time to spend with our kids andour spouses this year, and that’s a good thing. I had moretime to exercise and to laugh with friends. Some things,money can’t buy.

I didn’t worry this year, because I’m 60 years old, andI’ve learned that worrying never gets you anywhere butsick. Took me a while to figure that one out.

I got to read more and to think about our business. Thiswas a grand time to think, and I look at it as a gift. There’sso much going on in the world, so much to consider. Here’sa list of some of the stuff that caught my attention this year:

Efficiency. We got the news that 2009 was the best yearever for efficiency in the U.S. Each year, economists lookat how many Btu we used (from all fuels) per dollar ofGross Domestic Product produced. In 2009, it was just7,290 Btu per dollar, the lowest ever, and the results camelargely from our buying more efficient air conditionersand washing machines with smaller tubs. That makes methink that we’re going to keep the ball rolling by lookingat boilers and motors. There will be good business comingour way. Watch.

Tattletale garbage pails. Last summer a new traffic-light camera here in our town caught me. I was turning lefton the arrow and the light quickly went yellow and thenred as I was turning. Busted! They sent me the video andthe $54 fine, and I paid it. What can you do? Then I readabout these new trash cans in Cleveland that containmicrochips. The chip can tell whether you’re rolling thecan to the curb regularly. If you’re not, the garbage policeshow up and root through your trash, looking for thoseunseparated recyclables. Busted! Why are they doing this?To get more money for the city. There’s a business ineverything. You just have to open your eyes.

IKEA going geothermal. IKEA is building a newmegastore in Denver, and they’re going to heat this onewith geothermal energy. Ever been to an IKEA? You wan-der through a maze of furniture (only one way in and oneway out) and they give you cheese (or a Swedish meat-ball) if you make it all the way through. These places areenormous, and IKEA is one of the most eco-consciouscompanies in the world. They’ll make a big deal abouttheir new heating system in the Denver store. People willnotice, especially those who still question whether geot-hermal can work in a place like Denver, where the tem-perature can swing wildly and suddenly. That’s going tobe a good thing for all of us.

Solar forced-air furnaces. Nearly everyone inAmerica heats with a furnace, and the sun shines on mostdays, so when I read about the work that GoSolarUSA Inc.was doing, I sat up a bit straighter. The system they’retesting (for both commercial and residential buildings)grabs the heat from the sun, concentrates it and then pass-

es it into the moving stream of air from the ordinary fur-naces of America. The result is that these ordinary fur-naces burn less fuel. Sounds simple, doesn’t it? Why did-n’t we think of that?

Passive houses. You can heat most of these houses witha hair drier, because they’re that well built and that wellinsulated. The idea started in Europe (What a surprise!)and is now showing up all across America. Most of us areall about promoting high-efficiency heating equipment, butnothing beats starting out with a building that doesn’t needthat much heat, because it doesn’t lose that much heat. Thepassive house has the potential to change the entire HVACindustry in many ways. Keep your eye on this.

Radiant to radiators. I think that, to truly understandthe heating business, you have to look past the borders ofthe U.S. You have to look to Europe, where everyone hashydronics, and to China, which is a growing powerhousewhen it comes to radiators. Last year was a bad year forradiant heating in the U.K. Our British friends were late toarrive at the radiant party, which has been going on inEurope for 30 years. The U.K. had a solid radiant marketgoing, but the tubing was going mostly into luxury homesand do-it-yourself projects. The bottom fell out of thisbusiness in 2009. Meanwhile, the Chinese have been mak-ing lots of panel radiators. They made 360 million units in2006 and 460 million units in 2009. They’re projecting510 million units by 2012. Think that’s a trend?

Do-it-yourselfer? Want to save a buck? Clean yourown boiler, especially if it’s a very old boiler and youdon’t know what you’re doing. Start by having the wrongtools. Work alone and don’t tell anyone where you are orwhat you’re doing. You’ll either save a buck or you’ll getto cut off your own arm three days after it gets stuck insidethe old boiler. Jonathan Metz of West Hartford, Conn., gotto do the latter last summer. The good news is that, afterhe got on the news (all across the country), a local heatingcompany gave him a new boiler, and they installed it pro-fessionally. Great way to save money, eh?

Planned communities. Ah, another Pleasant ValleySunday, with rows of houses that are all the same. This yearbrought a couple of stories that caught my eye. One wasabout a man in a Florida planned community who wanted awhite roof instead of a black roof (which everyone elsehad). His thinking was that a white roof would cut down onhis air-conditioning bill. The community board wouldn’tallow that, of course. He could have any color roof he want-ed, as long as it was black. The other story came fromCalifornia, where the owner of a home in a planned com-munity installed a great-looking, passive-solar garage door,all with the idea of cutting his heating bill. The board saidno because it didn’t match the original metal doors thateveryone else had. They wanted him to put the old oneback. I don’t know how this one worked out, but the ownerhad a wonderful quote, “There are bigger problems in the

What a year!

Heating HelpDan Holohan, www.heatinghelp.com

Continued on page 34

pe12_pgs_32_35rev_Layout 1 11/30/10 11:17 AM Page 32

Page 33: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Superior effi ciency rules the water.

Think about ITT.

Powerful, intelligent and constantly in motion, not just adapting to their surroundings, but dominating them. Like sharks, e-SV pumps are tough, effi cient and built to last. Thanks to a unique combination of new hydraulic design and higher effi ciency motor, the e-SV delivers lower overall life-cycle costs and superior effi ciency compared to

most pumps available today.

• Optimized hydraulic design results in superior boosting performance, effi ciency and NPSHr levels.

• All stainless-steel construction permits NSF certifi cation.

• Expanded line of pump sizes for wide range of applications.

• Patented i-ALERT™ monitor continuously measures vibration to support optimum performance. Available on pumps 10HP and above.

• New design eliminates need to remove motor, reducing repair time by up to 50 percent.

Now there’s more than one way to rule the water.

Find out more at www.goulds.com

• Optimized hydraulic design results in superior boosting performance, effi ciency and NPSHr levels.

• All stainless-steel construction permits NSF certifi cation.

• Expanded line of pump sizes for wide range of applications.

• Patented i-ALERT™ monitor continuously measures vibration to support optimum performance. Available on pumps 10HP and above.

Introducing the Goulds Pumps

e-SVTM Series:energy effi cient, economical and easy-to-install stainless steel multi-stage pumps.

Circle 20 on Reader Reply Form on page 49

pe12_pgs_32_35rev_Layout 1 11/30/10 11:17 AM Page 33

Page 34: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

world than my garage door.” You think?Number one in heating! As if we needed another rea-

son to drink more beer. My favorite story to come out of2010 was the one about turning urine into fuel for ourhomes. The thinking (at the university level) goes likethis: Water contains hydrogen and hydrogen is a fuel.

Urine contains water and is expensive to get rid of becausewe have to treat it. So why don’t we figure out a way toextract the hydrogen from the pee and solve both prob-lems? Hey, I’ll drink to that! Stay tuned.

Solar without subsidies. Germany was a big proponentof solar heating, and they did a fine job of promoting thetechnology and subsidizing its installation. After a while,they declared the market to be mature, up on its feet,healthy, and no longer in need of any help from the feds.They diverted the subsidies to other markets. So what hap-pened? As soon as the crutches came out from under thearms of the solar industry, it collapsed. Think that couldhappen here?

Page 34/Plumbing Engineer December 2010

Heating HelpContinued from page 32

The views and opinions expressed in this column are those of the author anddo not reflect those of Plumbing Engineer nor its publisher, TMB Publishing.

Circle 21 on Reader Reply Form on page 49

Precision Plumbing Products“Specify with Confi dence - Install with Pride”®

The Prime-Pro™

potable water to the trap seal is essential in preventing sewer gas

The Prime-Pro™

The Prime-Pro™

PRIME-PRO™ FLOOR DRAIN TRAP PRIMERPRIME-PRO™ FLOOR DRAIN TRAP PRIMER

Precision Plumbing ProductsPART NO:

Low Lead Law

LOW LEAD

Show me the money. That’s what a lot of builders aresaying when it comes to seeking LEED certification. Thisyear brought stories about how there have not yet beenenough transactions of LEED-certified buildings to provethat the investment in energy-saving construction is some-thing that will reap a return. On top of this, builders inWashington State took the local government to court. Thebuilders claimed that the local governments are asking formore efficiency than the state demands and that’s going tomake new homes too expensive. No one asked the folkswho would be buying those homes and paying for the fuelhow they feel about this. Who cares about them?

All in all, I think it was a very good year to watch andto learn. Isn’t it wonderful to live in interesting times?

Here’s to 2011! n

Dan Holohan began his love affair with the heatingindustry in 1970. Today, Dan writes a monthly column forPlumbing Engineer’s sister publication, Phc News. Hehas written a dozen popular books on subjects rangingfrom steam heating to teaching technicians. He is wellknown throughout the heating industry for his entertain-ing and anecdotal style of speaking.

All in all, I think it was a very good year to watch and to learn. Isn’t it wonderful

to live in interesting times?

pe12_pgs_32_35rev_Layout 1 11/30/10 11:17 AM Page 34

Page 35: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Circle 22 on Reader Reply Form on page 49

pe12_pgs_32_35rev_Layout 1 11/30/10 11:17 AM Page 35

Page 36: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Page 36/Plumbing Engineer December 2010

Solar SolutionsBristol Stickney, technical director, Cedar Mountain Solar Systems, Santa Fe, N.M.

In small buildings, solar heated glycol can be easily cir-culated from solar heat collectors directly through thefloors. This provides the best possible heat transfer at

the highest possible system thermal efficiency. This hasoften been done in our area (northern New Mexico), par-ticularly in off-grid hydronic heating systems. It is alsooften implemented for simplicity as a way of reducing thenumber of electrical pumps and controls needed to run theheating system.

In larger and more complex hydronic heating systems,however, there is a point at which the cost and difficultyof dealing with large quantities of glycol becomes tooimpractical, messy or expensive. In most cases, it is stan-dard practice to install a solar heat exchanger to limit theuse of glycol only within the solar collector piping, so thatthe rest of the hydronic system can be filled with water.

In our solar combisystems constructed over the past fewyears, we have standardized placement of the main solarheat exchanger so that it is part of a primary loop used toconnect all of the heat sources to all of the heat loads inthe building. The simplest version of this type of system iscalled the “Combi 101 Check Loop.” You can find more

details about it, with diagrams, in previous issues of thiscolumn. We have also modified this approach in a numberof recent solar home heating installations to allow the useof hydraulic separators along with (or instead of) a prima-ry loop, while still using the same control system.

Figure 1 shows a Combi 101 solar heating systeminstalled in a home near Taos, New Mexico. In the photo,the DHW tank (white) is on the left, a condensing boilerbackup system is at the lower left (black) and the primarycheck loop and all the controls are in the center and to theright. A Voyager propane gas backup system is used here,where the DHW tank, with an in-tank coil, and the boilerare one integrated unit, which is also used as the only solarheat storage tank. There are four wall-mounted 4510 flatplate solar collectors connected through the main solarheat exchanger, which can be seen at mid-height, just tothe right of the white tank.

The brazed plate

Figure 2 (page 38) is a clasp of the solar heat exchang-er, which is a brazed plate design. This is not your grand-father’s shell and tube. A large surface area for heat trans-fer is folded into a very small rectangular package bystacking stainless steel plates and brazing the edges. Thesolar heat for this whole house can be delivered through aunit that is about the same size as a large circulator pump.

Stainless steel pipe nipples provide the four requiredpiping connections, two for the glycol side and two for thewater side. Counterflow fluid connections are most com-monly used, although parallel flow is also possible withthis unit with good results. The pressure drop through bothsides is very reasonable for commonly used circulatorpumps. Our installers added some brass unions and ballvalves to allow easy removal and inspection and mountedthe unit carefully to allow access to the unions for servicewith large wrenches on both sides.

Some practical issues and recommendations

There are a number of practical details that we havelearned over the years by using brazed plate heat exchang-ers in our solar hydronic heating systems:

• When choosing a solar heat exchanger, bigger is bet-ter. You will never regret putting in larger pipe diameters,less restrictive flow paths and more surface area for heattransfer whenever you can. So, when faced with a choiceof several similar heat exchangers, choosing the one thatallows greater heat flow is usually a good idea.

• The water side of a heat exchanger can freeze andbreak if very cold liquid glycol is allowed to circulatethrough it in winter. As a minimum precaution, the freezerecirculation setting on the solar control must be turnedoff and a spring check valve must be installed with the

Continued on page 38

Bristol’s Six Principles for Good Solar Hydronic DesignThe solar combisystem heat exchanger

Figure 1

pe12_pgs_36_39rev_Layout 1 11/30/10 11:21 AM Page 36

Page 37: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

are you saying that the speakman TP valve

protects from both scalding & Thermal shock?

and it’s certified to meet ASSE 1016

at 1.5 GPM!

...The Law Firm of Robbem, Cheatem, and Blindem is down in the dumps… Why?

THE NEW SPEAKMAN SENTINEL PRO™ TP SHOWER VALVE IS HERENO MORE EASY LEGAL SETTLEMENTS FOR HOSPITAL AND HOTEL SCALDING & FALLING PERSONAL INJURY LAWSUITS

DEFEND YOURSELFSpecify the new SENTINEL PRO™ TP SHOWER VALVE for maximum protection

CERTIFIED TO 1.5 GALLONS PER MINUTECall 800-537-2107 to learn more or visit us at www.SentinelProTPValve.com

Circle 23 on Reader Reply Form on page 49

pe12_pgs_36_39rev_Layout 1 11/30/10 11:21 AM Page 37

Page 38: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Page 38/Plumbing Engineer December 2010

these systems can be applied in a wide variety of buildinggeometries and orientations with few limitations. Brandnames, organizations, suppliers and manufacturers arementioned in these articles only to provide examples forillustration and discussion and do not constitute any rec-ommendation or endorsement. n

Bristol Stickney has been designing, manufacturing,repairing and installing solar hydronic heating systemsfor more than 30 years. He holds a Bachelor of Science inMechanical Engineering and is a licensed mechanicalcontractor in New Mexico. He is the chief technical offi-cer for SolarLogic LLC in Santa Fe, N.M., where he isinvolved in development of solar heating control systemsand design tools for solar heating professionals. Visitwww.solarlogicllc.com for more information.

solar glycol circulator pump.• The heat exchanger must be mounted so that the air

inside can find its way out. Figure 29-2 shows a properconfiguration, allowing air to rise up and out of both sidesof the heat exchanger. Mounting the unit with all of thepipe nipples facing upward is also an effective approach.

• Model numbers can be confusing from one brandname to another, since some refer to surface area and oth-ers refer to number of plates. Be sure you know which iswhich, especially when changing brands or trying to findequivalents.

• Only clean, recirculating boiler fluid is used in thisexternal heat exchanger, not potable water or fluid fromany open system. The potable water DHW tank is solarheated through an in-tank heat exchanger coil filled withboiler fluid (water) that is not susceptible to mineral clog-ging, sediment or dissolved oxygen.

• Different brand names sometimes offer widely vary-ing prices for virtually identical models. Be willing tocompare Flat Plate, Triangle Tube, Crown, Weil-McLainand other brands to find the best price.

Final notes

These articles are targeted toward residential and com-mercial buildings smaller than 10,000 square feet. Thefocus is on pressurized glycol/hydronic systems, since

Solar SolutionsContinued from page 36

In this series of articles, I have been making the case thatthe key ingredients for solar/hydronic design and installationcan be divided into six categories, listed below, roughly inorder of their importance.

1. RELIABILITY2. EFFECTIVENESS3. COMPATIBILITY 4. ELEGANCE5. SERVICEABILITY 6. EFFICIENCY

The success of any solar hydronic home heating installa-tion depends on the often-conflicting balance between any ofthese six principles. Finding the balance between themdefines the art of solar heating design.

The views and opinions expressed in this column are those of the author anddo not reflect those of Plumbing Engineer nor its publisher, TMB Publishing.

HIT ITNOW!

plumbingengineer-resource.com

Where plumbing engineers

go for the latest information from manufacturers.

Free information on products, training, and more…

all waiting for you!

Figure 2

Circle 28 on Reader Reply Form on page 49

pe12_pgs_36_39rev_Layout 1 11/30/10 11:21 AM Page 38

Page 39: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

TAP INTO OURRESOURCESIAPMO R&T offers certifi cation to every code and standard you need.

® ®)

® ®)

® ®)

® ®)

®

Circle 24 on Reader Reply Form on page 49

pe12_pgs_36_39rev_Layout 1 11/30/10 11:21 AM Page 39

Page 40: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Page 40/Plumbing Engineer December 2010

Niagara Conservation offers lead-free aerator

CedAr KNoLLS, N. J. — Niagara Conservation continuesto introduce innovations to its ultra high-efficiency watersaving product line. For example, Niagara’s four neweCoNo aerator model have bodies constructed entirely ofABS poly, creating a completely lead-free aerator and pro-viding safe source for drinking water.

Niagara offers two eCoNo aerators in 1.0 GPM flowrate in either a bubble (N3601B) or needle (N3601N)spray and the other two eCoNo aerators are offered in a1.5 GPM flow rate — also in both bubble (N3602B) orneedle (N3602N) spray. In the bubble spray aerator mod-

els from Niagara,air is inductedproviding a full,powerful streamthat uses lesswater and the nee-dle spray modelsoffer 18 individ-ual streams withthe ideal amountof pressure. All

the new Niagara eCoNo aerators are featured in aChrome finish.

Also, the patent-pending PoM dual-thread componentprevents stripping with no visible threads. In addition,Niagara’s patented non-removable pressure compensatorprovides a constant output of water regardless of pressureand the new aerators come with special install key, whichmeans no tools are required.

Plumbing Engineer’s

REPORT

Brought to you bi-monthly by

Superior Mfg. low lead products certified by NSF

NSF International Certified that the productsappearing below conform to the requirements of theLead Content Certification Program. The following isthe listing recorded on May 7, 2010.

Superior Mfg., A Division Magnatech Corporation 2015 South Calhoun Street Fort Wayne, IN 46802 800-348-0999 260-456-3596

Facility: Fort Wayne, IN Component[LL]C-10 C-100 C-200 C-25 C-5

C-50 C-75 MNW-20-150-S R-150 R-200

RT-1000 RT-500 RT-750 RX RX-Special

SF-1250-AC SF-1500-AC SF-2000-AC SF-2500-AC SF-3000-AC

SF-4000-AC

[LL] Product has a weighted average lead contentof <=0.25% and is in compliance with California'sHealth & Safety Code Section 116875 (commonlyknown as AB1953) and Vermont Act 193. Productwas evaluated using the lead content procedures ofNSF/ANSI 61 Annex G only, with the exception thatit was not evaluated for compliance with the chemi-cal extraction requirements of NSF/ANSI 61.

pe12_pgs_40_41rev_Layout 1 11/30/10 11:23 AM Page 40

Page 41: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Circle 25 on Reader Reply Form on page 49

pe12_pgs_40_41rev_Layout 1 11/30/10 11:23 AM Page 41

Page 42: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Tacoma, Wash. — Eagle Harbor Mechanical, anMCAA member in Poulsbo, Washington, installed a rain-water harvesting system to help make The Center forUrban Waters Building in Tacoma more sustainable withits water usage. The building is the City of Tacoma’s cen-terpiece for urban water quality and sustainability, sobeing LEED® certified was a priority.

In order to achieve LEED certification, every source ofwater usage and consumption was looked at for conserva-tion. The roof has more than 51,000 square feet of work-ing space and was large enough to utilize a rainwater har-vesting system for most of the building’s water needs. Thesystem could not only handle all of the urinal and toiletwater demands; it could also be used to irrigate the greenroof that was installed on the building.

Mark Bratonia of Eagle Harbor Mechanical knew thatJay R. Smith Mfg. Co.® could provide him with a pack-age of products that would meet his requirements. GregSkaggs with Braley-Gray Washington, the local Jay R.Smith Mfg. Co. representative, had worked closely withMark on other projects, so the two of them really under-stood the importance of the project. Mark stated, “Braley-Gray really does a good job of servicing their customers.Good factory reps are important; it’s the service behindthe product that separates them from others. This rainwa-ter harvesting project was different, and I knew that Jay R.Smith would be there until we got it right.”

The Center for Urban Waters project has several Jay R.Smith roof drains installed in the green roof. The roof

drains convey all of the rainwater collected from therooftop to the Vortex filters. Two RH9520-06 mediumcapacity vortex filters are installed directly under thegreen roof and feed two 36,000-gallon above ground, cor-rugated, galvanized steel rainwater storage tanks. The twostorage tanks are easily seen from the front of the build-ing. Their visibility does a wonderful job of promotingrainwater harvesting and the overall sustainability of theUrban Waters building.

The concept of harvesting rainwater is simple; rainwa-ter is collected from a rooftop. The harvested rainwater isconveyed through the piping to a filter that removes thedebris. From the filter, the collected rainwater enters thestorage tank through a smoothing inlet. The smoothinginlet prevents the agitation of sediment at the rainwaterinlet into the storage tank, and it aerates the water to keepit from becoming foul smelling. The stored rainwater isnow ready for use.

Harvested rainwater is extracted from the cleanest partof the tank, just below the surface of the water, using afloating filter and pump. The end result is filtered rainwa-ter that is ready to use for any indoor water applicationssuch as flushing toilets and urinals or for outdoor applica-tions such as irrigation.

Rainwater harvesting not only helps by re-using thewater; it also helps eliminate water runoff problems.Large commercial buildings have asphalt parking lots thatcan create problems during large rain events. Pollutantscan be carried down to storm gutters and out to streams

and rivers. Because of this, somelocal municipalities have startedlevying fines on businesses thathave excessive runoff problems.Mark Bratonia mentioned this,saying, “Here in Washingtoneverything runs to the rivers andout to the bays and then to theocean, so rainwater harvestingreally helped us avoid any poten-tial risks.”

The re-use of rainwater and theprevention of rainwater runoffthat the rainwater harvestingproducts provided has helped TheCity of Tacoma apply for LEEDplatinum certification, the highestrating possible under the LEEDranking system. n

For more information on rainwa-ter harvesting products and greenroof drains or to contact your localJay R. Smith Mfg. Co. representa-tive, visit www.jrsmith.com.

Product ApplicationRainwater harvesting products integrated

into green roof building plan

Stainless steel rainwater harvesting storage tanks help promote sustainability at TheCenter for Urban Waters building in Tacoma, Washington.

Page 42/Plumbing Engineer December 2010

pe12_pgs_42_43rev_Layout 1 11/30/10 11:25 AM Page 42

Page 43: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Plumbing Engineer December 2010/Page 43

Welcome to Plumbing Engineer’s 2010 InternetUsage Survey. We recently conducted anexclusive questionnaire that garnered a

tremendous response. The survey gives us a uniqueview of the Internet habits of today’s engineer, and over-all online trends. The questions range from work hoursspent on the Internet to social networking to RFIs.Nearly 40 percent of the respondents work at a compa-ny which has 50 or more employees; nearly 30 percentwork at a firm that employs 1-5 people. Here are theresults of the 2010 survey:

1. How much time do you spend on the Internet asit relates to work? Eighty-five percent said everyday,of which 35 percent spend an average of 30-60 minutes.Twenty percent spend 1-2 hours online and 16 percentclaimed 2+ hours.

2. Where do you go for product/technical informa-tion? Manufacturer websites was the resounding winnerat a 95 percent response rate. Trade publications andtrade publication websites received 65 percent and cata-logs garnered 59 percent of the tally.

3. Interested in the engineer’s purchasing habits overthe Web, we asked: do you make online purchases anddo you feel secure making those purchases over theInternet? Forty-five percent of the engineers surveyedsaid that do make purchases via the Web. Of those 45percent, 72 percent claim that they feel secure makingonline purchases.

4. Do you use the Internet for project managementpurposes? A surprising 65 percent do not use the Webfor any project management duties.

5. Do you use the Internet for BuildingInformation Modeling purposes? Again, a surprising

answer in that 60 percent of those polled claim that theydo not use the Internet for BIM purposes.

6. Do you use the Web for education and training?The plumbing engineers in the survey responded that 85percent of them use the Internet for education and training.

7. Are you currently using social media? Thirty-fivepercent of those asked currently employ social media. Ofthe thirty-five percent, 21 percent use Facebook, 17 per-

cent use LinkedIn, 10 percent use online forums andonly 4 percent use Twitter. The reasons for getting intosocial media? Increase brand awareness, build strongerrelationships with customers, announce services,improve the customer service experience, network and

maintain industry connections, Web meetings, educationand all other forms of basic information.

8. Do you receive Requests for Information(RFIs)? Seventy-six percent said they receive RFIs.

9. Do you receive email architectural drawings?Increasing efficiency in their jobs, sixty-three percent ofthe engineers tallied receive drawings.

10. Do you use the Internet from a mobile device?Less than half (46%) claimed they went mobile. n

Facebook: 21%

LinkedIn: 17%

Online Forums: 10%

Blogs: 8%

Twitter: 4%

Socialmedia

tools used

2010 Internet Usage Survey

Do you receive email RFIs?

Yes: 76%

No: 24%

Do you use the Internet foreducation/training?

Yes: 85%

No : 15%

pe12_pgs_42_43rev_Layout 1 11/30/10 2:03 PM Page 43

Page 44: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Page 44/Plumbing Engineer December 2010

Hot water balancing is a requirement of any plumbingsystem with more than one hot water return path. Itis typically covered in the specifications or general

notes and is the responsibility of the installing contractor,but how is it done? More importantly, is balancing possiblewith the configuration and components indicated? Withcommissioning coming to the forefront of design, thesequestions must now be answered and it is the plumbingengineer’s job to answer these questions specifically.

The purpose of balancing is to ensure a ready supply ofhot water within reach of each fixture. The pump providesthe circulation, but balancing is required to ensure that eachriser (or branch) receives its proportional share of hot water.Only then can a fixture expect to see hot water shortly afterit is opened. Before determining how much water needs tobe circulated, reasonable expectations should be set for hotwater delivery times.

It must be understood that the branch from a riser or othercirculated loop is a “dead leg.” Water does not circulatethrough this pipe, so over time its heat will be lost. The timeit takes to get hot water from a circulated loop to a fixtureis a function of the pipe size and the flow rate of the fixture.

In most public installations, there are flush valve waterclosets which will require 25, 30 and often 35 psi at the fix-ture. We use this number in our pipe sizing calculation onevery job. The lavatory next to the most remote water clos-et, however, only needs 15 psi. In fact, 35 psi at a lavatorycan make quite a splash. Why then do we insist on ¾"branch piping to serve the lavatory? It delivers the excesspressure we don’t want and increases our waiting time forhot water.

First, the lavatory has a flow restrictor which reduces theflow to about 0.5 gpm. The faucet manufacturer should becontacted to see how this flow varies with pressure, but let’sassume 0.5 gpm at 20 psi. Dividing by 60, we get 0.008 gal-

lons per second. Next, ½" type “L” copper pipe contains0.012 gallons per foot. Dividing the first by the second, weget 0.66 feet per second. This means that we have to circu-late with 15 feet of a faucet to provide a 20 second delivery.Since the drop to the faucet is probably 8 feet, the circulat-ed branch must pass within 7 horizontal feet of the fixture.The volume of ¾" type “L” copper is slightly more thantwice that of ½" pipe, making a 20-second delivery impos-sible without circulating directly overhead or in the wall.

How about showers? First, I would not sacrifice pressurehere. With 2.2 gpm flow restrictors, and 103 degree mixingvalves, pressure is about the only luxury left in a shower. Atalmost five times the flow, using ¾" pipe, we can be overtwenty feet away from our circulating loop and still have a20 second delivery time. Remember, unlike lavatories, peo-ple don’t give up and walk away after 10 seconds.

Flow rate

The flow rate of the system needs to bring heat back tothe system faster than it is lost through the piping. To deter-mine how much heat is lost, the pipe size, insulation valueand total length of piping is needed. Heat loss per foot ofpipe is typically represented as shown in Table 1. Hot watersupply risers should be calculated individually and mustinclude hot water supply and return piping to and from thenext riser as well as it's proportional share of the main dis-tribution. This last point has been the cause of failure onmany hot water circulating systems.

For example, a simple 6-story riser might include 20 feetof 11/2" pipe, 30 feet of 1" pipe and 30 feet of 3/4" pipe. Thesupply and return piping to and from the source amounts to200 feet of 2" Pipe and 100 feet of 1" pipe shared between10 risers. The heat loss here would be (20 x 9.6) + (30 x12.4) + (30 x 10.6) + (200/10 x 11.5) + (100/10 x 12.4) =1059 btu/hr. The acceptable heat loss must then be calculat-ed. assuming a 10 degree temperature difference betweensupply and return, the heat loss can be converted into a flowrate using the formula below.

This should be rounded up to 1/3 or 1/2 gpm. This pro-vides a safety factor in the calculation and some tolerance

Table 1: Heat Loss Per Linear Foot

Hot Water BalancingBy Peter Kraut

pe12_pgs_44_45rev_Layout 1 11/30/10 11:29 AM Page 44

Page 45: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Circle 26 on Reader Reply Form on page 49

engineers and contractors are resort-ing to the worst balancing valve onthe market: the ball valve. The bal-ancing procedure for these is rathersimple. Give it a quarter turn and hopefor the best. n

Peter A. Kraut, P.E., is a licensed

Mechanical Engineer in 23 states. He

founded South Coast Engineering Group,

near Los Angeles in 2001. He can be

reached via email at [email protected].

Plumbing Engineer December 2010/Page 45

for the contractor in the field. Sinceeach of the 10 risers will circulate ½gpm, the system will need to move 5gallons per minute. At this time,velocities in hot water return pipingshould be checked to ensure a maxi-mum of 5 feet per second.

Pressure drop

A recent project in Los Angelesrequired the contractor to balance over130 risers to 0.3 gpm each. To stayabove the heat loss and below thevelocity requirements, balancingneeded to be within 0.02 gpm. A diffi-cult feat to begin with, this taskbecame near impossible when consid-ering that the flows came from fivedifferent buildings of different sizesand configurations. First, reasonableexpectations were developed. Thisincluded flow rates around 0.5 gpmper riser with a tolerance of ± 0.1gpm. Second, the worst case pressuredrop was calculated for sizing thepumps. Third, the pressure dropthrough the next closest riser was cal-culated and a value for a pre-calibrat-ed balancing valve was given. Thiswas done for each of the subsequentrisers. Fourth, the balancing valveswere set to their assigned values.Fifth, the balancing valves were mea-sured to insure flow and fine adjust-ments were made. An over-simplifiedexample with 4 risers is shown inFigure A: Hot Water Circulation.

In this example, riser A is notice-ably further than riser D yet to getequal flow, the head loss in each pip-ing segment must be equal. Since thehot water supply is sized for the fix-ture flow rates, the head loss from cir-culation in such large pipe is oftennegligible. If this is true, the head lossin the balancing valve at the top ofriser B should be equal to the headloss in the pipe segment E. Similarly,the head loss in the balancing valve atthe top of riser C should be equal tothe head loss in the pipe segments Eand F. Finally, the head loss in the bal-ancing valve at the top of riser Dshould be equal to the head loss in thepipe segments E, F and G. For non-similar risers a more in-depth calcula-tion is necessary. When larger areasare connected to a single hot water cir-culator, additional sectional balancingvalves are recommended.

There are many types of balancingvalves available. Some have calibrat-ed scales with literature and guides

for calculating pre-set values. Othersrely solely on electronic devices formeasuring flow in the field. Thedilemma that many engineers face isthat few of these are listed for use in adomestic water system. Worse yet,none of them are currently listed withNSF or IAPMO for conformance withAB1953, California’s tough new lead-free ordinance. Unfortunately, sincemost globe valves lack the listing forconformance with AB1953, many

pe12_pgs_44_45rev_Layout 1 11/30/10 11:29 AM Page 45

Page 46: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Page 46/Plumbing Engineer December 2010

With the green movement on the rise, homeown-ers are overwhelmed with tips and advice onhow to conserve water and energy.

Replacing the standard (2.5 gallon per minute)showerhead a low flow showerhead (less than2.5 gpm) is a frequently recommended way to“go green.” As a result, low flow showerheadshave been evaluated and rated by reporters,consumer bloggers and the EPA’s WaterSenseprogram, based on the showerhead’s perfor-mance. This information has been consumed byeco-friendly homeowners in hopes of getting guid-ance in their showerhead selection process.

Lost among the buzz about low flow showerhead attrib-utes is information about shower valve compatibility.Surprisingly, an important factor in selecting the low flow

showerhead that offers the best showering experience issomething that can have a dramatic effect on the safety ofyour showering experience; the shower valve.

What’s behind the wall makes a difference

Behind the wall in every shower or tub/shower combi-nation is a mixing valve that blends the hot and cold water.Recent plumbing codes require mixing valves installed inshowers to be safety-type valves, which have a mecha-nism inside that compensates for pressure disturbancesthat cause changes in the outlet water temperature.

There are two types of safety valves installed in mostshowers, thermostatic valves and pressure balancing valves.

Thermostatic valves reactto temperature changes in

the water that result froma disturbance in water

pressure within theplumbing system.Pressure-balancingvalves react instantly tothe pressure disturbance

within the plumbing sys-tem to maintain a safe, pre-

selected water temperature. If you have ever experienced the sudden change in

water temperature when a toilet is flushed or a washingmachine cycle begins, you have experienced thermalshock. Thermal shock is a safety concern for bathers, notonly because it can result in scalding of the skin but alsobecause, more commonly, the bather suffers slip and fallinjuries as he or she reacts quickly to avoid the suddenchange in temperature in the water flowing out of theshowerhead.

Shower safety valves are designed to react and adjust tothese disturbances in water pressure within the plumbingsystem and, consequently, they maintain safe water temper-atures, providing bathers a comfortable and enjoyableshower. Furthermore, certified shower safety valves mustadhere to a standard as set forth by the American Society ofSanitary Engineers, listed as ASSE 1016 – AutomaticValves for Individual Showers & Tub/ShowerCombinations. Minimum test requirements within this stan-dard mandate that a safety-type valve maintain the bather’sset outlet water temperature at a flow rate of 2.5 gpm.

How pressure-balancing valves

support low flow showerheads

As previously stated, safety valves work properly with a

By Tim Kilbane

­Safety­and­Low­Flow

Showerheads

Lost among the buzz about low flow showerhead attributes is information about

shower valve compatibility.

pe12_pgs_46_47rev_Layout 1 11/30/10 11:54 AM Page 46

Page 47: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Circle 27 on Reader Reply Form on page 49

and valve performance. In the future,consumers will have a better guidefor compatibility because manufac-turers will publish in their literatureand on their packaging the valve andshowerhead flow rates.

So, regardless of the latest con-sumer report on low flow shower-

heads, knowing the type of valve thatis behind the shower wall could havethe biggest influence on a decision inselecting the safest water and energyconserving showerhead. n

Tim Kilbane is the national salesmanager of Symmons Industries.

standard 2.5 gpm showerhead becausethey have been mandated to do so byASSE 1016. However, the same valvemay not work properly in combinationwith a low flow showerhead at a flowrate lower than 2.5 gpm. This is impor-

tant for the consumer to understand,because, if the valve is unable toaccommodate a change in pressure as aresult of the low flow showerhead, itmay not be able to maintain safebathing temperatures.

Until a standard is published forshowerheads and valves operating atflow rates lower than 2.5 gpm,bathers need to understand the impor-tance of the valve and showerheadcompatibility. For the safest showerexperience, consumers and installers

should contact thevalve manufacturerand verify that theflow rate of the

showerhead iscompatible withtheir showervalve.

Low flow in

the future

Manufacturersare working with

industry organizations and standardsdevelopers to prepare standards forthe safety of low flow showerheads

Plumbing Engineer December 2010/Page 47

Knowing the type of valve that isbehind the shower wall could have aninfluence on purchasing decisions.

pe12_pgs_46_47rev_Layout 1 11/30/10 11:54 AM Page 47

Page 48: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Classified Ads

Please contact SadieBechtold by phone at

847-564-1127 or email [email protected] to

place your classifiedadvertisement today!

Page 48/Plumbing Engineer December 2010

HVAC OR WATER HEATERTECHNICAL SPECIALISTDescription:A.O. Smith Water Products Company (WPC), aleading manufacturer of residential and commercial water heaters and boilers, issearching for Technical Specialists near Nashville, TN and near Dayton, OH.

The primary responsibility of the Technical Specialist is to assist callers with questionsregarding commercial product. This includes questions regarding operation, generaland complex installation, troubleshooting and repair of entire commercial product linefor all brands, cross-referencing, sizing, and more. Also serves as back-up support forresidential water heaters for all A.O. Smith branded product.

Special Requirements:The ideal candidate will possess:• BS degree or 8 years combination of related field experience/education/training.• A thorough understanding of the design, function, installation, operation, and repairof all water heaters, pump tanks, expansion tanks, and commercial water heaters andboilers.• Familiarity with National Fuel Gas Code, National Electrical Codes, National BuildingCodes, and ASME laws.• Tact and the ability to work well with the public.• Working knowledge of Microsoft Office.• Good typing skills.• HVACR Field Experience• Electronics Technician• Automotive Technician/Auto Mechanic• Boiler Operator License/Experience• Commercial Installation and Repair Experience• Engineer/Engineering Education or ExperienceQualified individuals should send their resumé to:

[email protected]. Smith Water Products Company is an equal opportunity employer

Industry Movers

wooDrIDGe, ILL. — Gerber PlumbingFixtures LLc added Dave Stuker andJohn Perkins to the company’sexpanding sales team. Stuker willserve as the territory manager for newconstruction, and Perkins will be thewestern regional builder manager.

Mestek names project engineering supervisor

ence in the plumbing and HVAcindustries. Todd Anderson joinswebstone after holding positionswith Georgia-Pacific corporation,kohler company andUponor/wirsbo. Fred

Hoffman has spent hiscareer working at everystop in the channel fromtradesman to whole-saler to rep and nowmanufacturer, managinginstallations, sales and sales reps.

Gerber appoints two managers

weSTFIeLD, MASS. —Thomas Neill was pro-moted to the position ofsupervisor for projectengineering at Mestek.

BoSToN — Vanderweil engineers,one of the nation’s largest and mostexperienced mechanical and electri-cal consulting engineering firms,announced that James E. Foster has

Vanderweil Engineers addsmechanical/plumbing designer

joined the Las Vegas office as amechanical/plumbing designer.

ROTHENBERGER USA namesvice president/general managerrockForD, ILL. —roTHeNBerGerUSA named Chera

M. Ellis vice presi-dent/general manag-er of rothenbergerUSA/a GreenleeTextron company. ellis replaceschris Vernon, who is now vice presi-dent of marketing and product man-agement at Jacobsen Textron.

worceSTer, MASS. —webstone continues tostrengthen its manage-ment team with twonew regional sales man-agers, both with morethan 20 years experi-

Webstone appoints regionalsales managers

Anderson

Hoffman

New York — The engineering firmwSP Flack + kurtzannounced that Tom

Marseille, Pe, LeeD®AP, will assume the roleof managing director ofits Seattle office, effec-tive January 1, 2011. Heis taking over the role from Henry DiGregorio. Di Gregorio has been dedi-cated to wSP F+k for more than 43years and will retain a leadership roleat the firm.

WSP Flack + Kurtz namesmanaging director — Seattle

pe12_pgs_48_49rev_Layout 1 11/30/10 1:43 PM Page 48

Page 49: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

AHR Expo.....................................................................................................35American Standard ....................................................................................13ANACO...........................................................................................................11Aquatherm....................................................................................................12Charlotte Pipe & Foundry .......................................................................IFCGerber............................................................................................................25Goulds Pumps.............................................................................................33Haws ................................................................................................................5Heating Help.com .......................................................................................47Holby..............................................................................................................10IAPMO...........................................................................................................39Josam..............................................................................................................9Leonard Valve ................................................................................................7Liberty Pumps.............................................................................................29

Mifab..............................................................................................................16Navien America ..................................................................................27, IBCPlumberex.......................................................................................................3Plumbingengineer-resource.com ............................................................38Powers Process ..........................................................................................31Precision Plumbing Products ..................................................................34Red White Valve Corp................................................................................17Smith Mfg. Co., Jay R. .............................................................................45Speakman Co. .............................................................................................37Stiebel Eltron ...............................................................................................23Viega........................................................................................................18-19Watts ............................................................................................................21Woodford Mfg. ...........................................................................................15Zurn Plumbing Products, LLC..........................................41, Back Cover

Plumbing Engineer December 2010/Page 49

Advertiser Index

December2010

Please fill out this Reader

Reply form andfax it to us at630.739.9700 to receive the information youhave requested.

I wish to receive (continue receiving ) Plumbing Engineer for FREE

c Yes c No

I am engaged in plumbing engineering: c Yes c No

I am also engaged in the following kinds of engineering work:

c Piping (a) c HVAC (b) c Hydronics (c)

c Sprinkler/Fire Protection (d) c Plumbing (e)

I am employed by one of the following:

c Architectural/Engineer (a) c Mechanical Engineer (b) c Building

Owner/Engineer (c) c Consulting Engineer (d) c Contractor (e) c Design-

Construct Engineer (f) c Architect (g) c Manufacturer (h)

c Manufacturers Rep (i) c Government (j) c Other (x)

My title is: c Construction Manager (c) c Engineer (e) c Owner (o) c

President (p) c Specifier/Design (s) c Vice President (v)

c Other

Do you design and specify products? c Yes c No

I belong to the following professional organizations:

c ASPE (a) c ASSE (b) c ASHRAE (c) c NSPE (d) c Other (e)

1

2

3

4

5

6

7

Please circle the number that corresponds to the information you’ re interested in.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1718 19 20 21 22 23 24 25 26 27 28 29 30 31 3233 34 35 36 37 38 39 40 41 42 43 44 45 46 4748 49 50 51 52 53 54 55 56 57 58 59 60 61 6263 64 65 66 67 68 69 70 71 72 73 74 75 76 7778 79 80 81 82 83 84 85 86 87 88 89 90 91 9293 94 95 96 97 98 99 100 101 102 103 104 105106 107 108 109 110 111 112 113 114 115116117 118 119 120 121 122 123 124 125 126 127 128 129130 131 132 133 134 135 136 137 138 139 140 141 142143 144 145 146 147 148 149 150 151 152 153 154 155156 157 158 159 160 161 162 163 164 165 166 167 168169 170 171 172 173 174 175 176 177 178 179 180 181182 183 184 185 186 187 188 189 190 191 192 193 194195 196 197 198 199 200 201 202 203

Name/Title

Company

Street Address Box No.

City State Zip

Telephone Fax

Email

Signature (required)

Please fill out this form, sign and date below8

Subscribe online atwww.plumbingengineer.com

pe12_pgs_48_49rev_Layout 1 11/30/10 1:43 PM Page 49

Page 50: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Haws partners with Brita® BrandThe Brita® Hydration Station™ is atouch-free, hygienic, water dispenserthat allows users to enjoy the benefitsof healthier, great-tasting wateraway-from-home. TheB r i t a ®HydrationS t a t i o n ™encourageshydra t ionwith itsaesthetical-ly appeal-ing design,can helpsave moneywhen usedas an alter-native tob o t t l e dwater andh e l p sencouragesustainability efforts. Haws Co.

Circle 104 on Reader ReplyForm on page 49

SentinelPro™ T/P shower valve lineThe SentinelPro T/P is a dual element thermostatic and pressure balanced valve,which is certified to meet ASSE 1016 at 1.5 gallons per minute. TheSentinelPro’s dual element design allows the valve to protect against both scald-ing & thermal shock at flow rates as low as 1.5 gallons per minute. The need forT/P valves has become increasingly important with low flow showerheads.When using a low flow showerhead the potential for thermal shock and scald-ing situations increases. The valve is often overlooked when low flow shower-heads are specified. Speakman.

Circle 100 on Reader ReplyForm on page 49

HALO eye/face wash Arms users with themost effective emer-gency relief availablein the industry.Designedw i t hthe lat-est tech-nology influid dynamics, HALO covers85 percent of the user’s face,which is more than 20 percentbetter protection than any othereye/face wash on the market.With more coverage and a supe-rior wash pattern, users attainthe greatest contaminant reliefand protection available.Bradley Corp.

Circle 101 on Reader ReplyForm on page 49

Tankless gas water heatersThe new comprehensive line of tank-less water heaters offers a wide rangeof products including condensingmodels with higher efficiencies andheavy-duty commercial models.Models offer improved flow rates for

increased hot water delivery. On topof excellent performance and highefficiency ratings, tankless units alsooffer optional remote temperaturecontrollers and full line of acces-sories. A.O. Smith.

Circle 102 on Reader ReplyForm on page 49

Variable speed drivesAdvantage drives combine the manu-facturer's proven pumping technolo-gy with Schneider’s variable frequen-cy drives, now complete with SquareD enclosures to provide advanced,user-friendly technology. Whenmatched with optimal output ofequipment, the drives will delivermore reliable performance andincrease productivity while reducingenergy costs. Taco.

Circle 103 on Reader ReplyForm on page 49

Product NewsPlumbing Engineer’s Product of the Month

Page 50/Plumbing Engineer December 2010

pe12_pgs_50_52rev_Layout 1 11/30/10 1:44 PM Page 50

Page 51: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Circle 29 on Reader Reply Form on page 49

pe12_pgs_50_52rev_Layout 1 11/30/10 1:44 PM Page 51

Page 52: Hot Water Balancing - PHCP Pros...Hot Water Balancing Inside this issue •2010 Internet Usage Survey •Safety and Low Flow Showerheads •Product Application: Rainwater Harvesting

Be a Step Ahead with Zurn andBuilding InformationModeling

ZURN ENGINEERED WATER SOLUTIONS™ 3D CAD FILES NOW AVAILABLE

At Zurn, we know that the requirements for design

and construction professionals are ever-evolving

and the bar for a higher standard of informational

competency is rising. As a leader in the industry,

we are committed to helping specifi ers create a

framework for interoperability, making projects

more effi cient and cost-effective. That is why we are

pleased to make 3D CAD and Revit fi les available for

a wide range of our products.

Files for Wilkins Backfl ow Preventers, Zurn Floor and Shower Drains, Carriers, Fixtures, Flush Valves and Faucets are now available in RFA, DWG, and DXF formats at www.zurn.com

Circle 30 on Reader Reply Form on page 49

pe12_pgs_50_52rev_Layout 1 11/30/10 1:44 PM Page 52