GC-1809-02
Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China 519070Tel: (+86-756) 852 2218 Fax: (+86-756) 866 9426Email: [email protected] Http://www.gree.com
GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI
Unit 2612, 26/F, Mira Place Tower A, 132 Nathan Road, Tsimshatsui, Kowloon, Hong KongTel: (852) 3165 8898 Fax: (852) 3165 1029
HONG KONG GREE ELECTRIC APPLIANCES SALES LIMITED
Note:Gree is committed to continuously improving its products to ensure the highest quality and reliability standards,and to meet local regulations and market requirements.
All features and specifications are subject to change without prior notice.
All images provided in this catalogue are used for illustration purposes only.Copyright© Gree Electric Appliances, Inc. of Zhuhai. All rights reserved.
Distributor information
U-MatchEU 50/60Hz R32
Gree Electric Appliances, Inc. of Zhuhai, founded in 1991, is a diversified international industrial group, whose business covers residential air conditioners, central air conditioners, intelligent equipments, home appliances, air source water heaters, smart phones, refrigerators, etc.
● Since 2005, Gree has topped No.1 in production and sales volume of residential air conditioners for 13 consecutive years.● 2015, Gree's sales revenue exceeded 15.08 billion USD.● 2016, sales revenue exceeded 16.51 billion USD.● 2017, sales revenue exceeded 22.21 billion USD.● 2018, Gree entered into the list of Forbes Global 2000 again and ranked No. 294, moving up 70 places com-pared with the previous year.
Gree has paid some 14.26 billion USD in total tax, being the No.1 in terms of tax payment in the Chinese home appliances industry for 16 consecutive years.
Thanks to 300 million users ' choices, Gree products are widely sold in more than 200 countries and regions. Today Gree's annual production capacity of RAC and CAC is more than 60 million and 5.5 million sets respectively.
Action makes the future and innovation makes achievement. Looking forward, Gree will press ahead with its business philosophy of passion, innovation and realization. We aim to build an air conditioning enterprise of some hundred year's standing, to create a better life for humankind.
MADE IN CHINA LOVED BY THE WORLD
CONTENTS01 Why Choose GREE U-Match
07 Preview of Outdoor Models
08 Detailed Information of Outdoor Models
09 Preview of Indoor Models
10 Functions of Indoor Units
12 360°Air Discharge Cassette Unit
15 Compact Cassette Unit
17 Ultra-thin Air Duct Unit
19 High Static Pressure Air Duct Unit
22 Floor Ceiling Unit
26 Wall-mounted Unit
28 Floor Standing Unit
30 Control System
* Source: Euromonitor International Limited; Consumer Appliance 18ed;
retail volume sales in units, 2017 data.
Gre
e is
the
numbe
r one brand of air conditioners in the world in 2017
WHY ? Choose GREE U-Match
Complete Product Lineup
1*: We have single-phase/3-phase outdoor units for cooling capacity of 100, 125, and 140.2*, 3*: Under Development.
Cooling operation range
Heating operation range
● 68% lower GWP than that of R410A.● 30% lower refrigerant charge compared to R410A.
Adopt Eco-friendly Refrigerant R32
32 SEER7.2
I-Demand25%
● Energy efficiency grade in cooling is up to A++, and in heating is A+; SEER in cooling is up to 7.2.● Power consumption in standby status is only 1W.● I-Demand function, with 25% power saving.
High Energy Efficiency Economic
Adopt Eco-friendly Refrigerant R32 High Energy Efficiency, Economic
Complete Product Lineup Wide Operation Range
Highly Comfortable Smart Convenient Control
Easy Installation and Maintenance Highly Reliable
User-friendly Design
2
3
Wide Operation Range
● Operation Range for Cooling: -20℃(DB) ~ 48℃(DB)● Operation Range for Heating: -20℃(DB) ~ 24℃(DB)
-20℃ 48℃
-20℃ 24℃
4
Cooling Capacity1* Cassette Type Duct Type Floor Ceiling Type Wall-mounted Type2* Floor Standing Type3*
35 √ √ √
50 √ √ √
71 √ √ √ √ √
85 √ √ √
100 √ √ √ √ √
125 √ √ √ √
140 √ √ √ √
160 √ √ √
1
01 0201 02
Power Ordinary mode
I-Demand power upper limit
75%
Highly Comfortable
● Our compressor intelligently regulates its running frequency. When the difference between room temperature and the set temperature is large, our compressor will run at high frequency; when the difference is small, our compressor will run at low frequency. With accurate temperature control, it provides users with a highly comfortable experience.
The unit can select modbus gateway (long-distance monitor ME50-00/EG(M))to connect to the BMS control system. One network can connect up to 255 devices.
● It is capable of fast cooling, fast heating, and can quickly reach the user’s set temperature.
● Quiet designBoth indoor and outdoor units can run quietly, with no noise disturbance to your neighbors while providing you with a quiet and comfortable environment.
● Sleep Mode means the unit will enter sleep control logic, providing users with comfortable sleeping temperature.
● I Feel Function enables the unit to sense the actual temperature around the user.
● Double temperature sensors are available for air return (wired controller is needed). User can select the location of air return temperature sensor for more accurate sensing of room temperature and thus a high degree of comfort.
● Gree Intelligent Defrosting Technology enables the unit to correctly judge the frost of its outdoor condenser using a temperature sensor. “Defrost what is frosted.” Heating effect is enhanced, for a comfortable room.
● Cold air prevention allows the unit to control the start of indoor fan and air swing angle intelligently to prevent cold air blowing toward people when heating is turned on.
Fast cooling, fast heatingGREE U-Match
Other brands
Smart Convenient Control
● Smart APP control
5
6
Ordinary defrosting
Heating
Defrosting Defrosting Defrosting
Heating capacity
Time
Defrosting
Heating capacity
Heating
TimeGree intelligent defrosting
● Remote control
● Centralized control Model: CE52﹣24/F(C) Dimension (H×W×D): 128.2mm×185.2mm×54mm Centralized control for up to 36 indoor units, including GREE GMV5 series products. Basic control includes On/Off, mode, fan speed, temperature, etc. MODBUS gateway required.
03 04
Highly Reliable
● The longest connection pipe can be 75m long.
● The biggest drop difference is 30m.
● Dual unit backup function: when one unit breaks down, the backup unit can start operation at once; when one unit cannot hold the demand, the backup unit can start working to supplement the output.(under development)
● Chassis defrost: chassis with electric heating belt is optional for users to deal with the problem of chassis frost in extreme climate.
● Multiple defrosting modes are preset so that the unit can be frost-free even where the installation is not ideal.
● Low-temperature drying: reliable drying under 12℃.
User-friendly Design
● 8℃heating: in winter, if you are away, the unit can maintain room temperature at 8℃, to care for your pets and plants.
● Power-off memory function: in case of power failure, unit can remember the operating condition and restore the previous operating condition when power is resumed.
● Temperature can be set in auto mode.
● Timer mode is for users to preset the time for unit On/Off.
● Ambient temperature check: user can check indoor ambient temperature, outdoor ambient temperature and the set temperature through wired controller or remote controller.
8
9
● Less weight, more compact, the maximum cooling capacity of an outdoor unit with a single fan can reach 14kW.
● Air return filter cleaning indication is designed to remind users to clean filter when due. User can set different schedules to suit local conditions. ● Malfunction self-diagnosis, dual-8 bit display, clear display of unit information.
Easy Installation and Maintenance
● One to many: one outdoor unit can be connected to 2, 3 or 4 sets of indoor units of the same cooling capacity and the same type.
● The tallest outdoor unit with a single fan is only 820mm.
7
● System parameters check: user can check parameters of sensors through the wired controller, which is convenient for maintenance.
● Historical errors check: user can check historical errors through the wired controller to locate the error quickly.
● Refrigerant recovery mode: if malfunction occurs to indoor unit, outdoor unit can turn on the refrigerant recovery mode to reclaim the refrigerant. This is to reduce the harm of refrigerant leak and save the cost of refrigerant charging.
● Compulsory operation mode: once installed, the unit can quickly check whether the operation is normal.
● Compulsory defrosting: user can set defrosting manually, for the convenience of maintenance.
● Re-use of connection pipes: old engineering pipes can be re-used for the convenience of installation, saving time and material cost.
Dual-8 bit board of cassette type unitDual-8 bit board
of floor/ceiling unit
596mm 698mm 790mm 820mm
05 06
U-Match 5
System Type Model Designation 100 125 140 160
Air cooled Heat pump GUD**W/NhA-T -
Air cooled Heat pump GUD**W/NhA-X
GUD**T/A-T,GUD**P/A-T, GUD**PS/A-T, GUD**PH/A-T, GUD**PHS/A-T,GUD**ZD/A-T
Cooling Capacity 35 50 71 85 100 125 140 160
GUD71W/NhA-T 2 1
GUD85W/NhA-T 2 1
GUD100W/NhA-T GUD100W/NhA-X 3 2 1
GUD125W/NhA-T GUD125W/NhA-X 4 3 2 1
GUD140W/NhA-T GUD140W/NhA-X 4 3 2 1
GUD160W/NhA-X 4 3 2 1
Note: if outdoor unit is to be connected with multiple indoor units, the indoor units must have the same cooling capacity and be of the same type.
System Type Model Designation 35 50 71 85
Air cooled Heat pump GUD**W/NhA-T
Product Features● SEER in cooling is up to A++, and SEER in heating is up to A+.
● Compressor intelligent frequency regulation, accurate temperature control.
● Reliable cooling and heating at -20℃.
● The maximum length of connection pipe is 75m and the biggest drop difference is 30m.
● One connected to two, threeor four.(under development)
● Efficient noise reduction axialflow fan.
● It is capable of fast cooling, fast heating, and can reach user’s set temperature quickly.
● Gree Intelligent Defrosting Technology enables the unit to correctly judge the frost of outdoor unit through temperature sensor. “Defrost what is frosted.” Heating effect is enhanced, for a comfortable room.
● Dual unit backup function: when one unit breaks down, the backup unit can start operation at once; when one unit cannot hold the demand, the backup unit can start working to supplement the output.(under development)
● Chassis defrost: chassis with electric heating belt is optional for users to deal with the problem of chassis frost in extreme climate.
Combination relationship for one connected to many
Preview of Outdoor Models
Detailed Informationof Outdoor Models
0207 08
Type Features Model Picture 35 50 71 85 100 125 140 160
Cassette Type
360° air outflow, swing panel independent control GUD**T/A-T √ √ √ √ √
360° air outflow, perfect match with the ceiling GUD**T/A-T √ √
Duct Type
Super thin, quiet, air swing panel GUD**P/A-T √ √ √ √
Super thin, quiet, air swing panel, water pump GUD**PS/A-T √ √ √ √
High static pressure GUD**PH/A-T √ √ √ √
High static pressure, water pump GUD**PHS/A-T √ √ √ √
Floor Ceiling Type Floor ceiling GUD**ZD/A-T √ √ √ √ √ √ √ √
Wall-mounted Type Wall mounted GUD**G/A-T √ √
Floor Standing Type Floor standing GUD**L/A-T √ √ √ √
Function Description Duct Type Cassette Type
Floor Ceiling Type
Comfort
Fast cooling, fast heating If room temperature varies a lot from the set temperature when the unit is turned on, fast cooling or fast heating will be enabled. √ √ √
Smart sensor(under development)
Detect occupants’ condition in the room to activate smart control over the air conditioner √
Quiet mode Both indoor and outdoor units can be running in quiet mode, avoid disturbing neighbors while providing users with comfort √ √ √
Sleep mode The unit can enter sleep control logic to provide users with comfortable sleeping temperature. √ √ √
I-FEEL Accurately sense the temperature around the user √ √ √
Cold air prevention When heating mode is turned on, the unit can control indoor fan and air swing angle intelligently to prevent cold air blowing toward people √ √ √
Double temperature sensors for air return
User can select the location of air return temperature sensor so that the unit can accurately sense room temperature and improve the comfort degree (Wired controller is necessary).
√ √ √
Intelligent defrostingGree Intelligent Defrosting Technology enables the unit to correctly judge the frost of outdoor unit through temperature sensor. “Defrost what is frosted.” Heating effect is enhanced, for a comfortable room
√ √ √
Auto mode Automatically switch between cooling mode and heating mode to realize the set temperature √ √ √
Air flow distribution
Swing panel independent control(under development)
For cassette type unit, swing angle of each swing panel can be controlled independently to satisfy different demands for installation space and angles (exclude compact cassette type unit)
√
Filter cleaning reminder User can set different reminding time based on different installation condition. When time is up, the unit will remind user to clean the filter. √ √ √
360° air outflow Room temperature is more balanced √
Swing panel of duct type unit(under development)
User can control air flow direction to enjoy more balanced temperature (For ultrathin duct type unit only) √
Auto air swing Swing panel can realize auto air swing (This function is available in cassette type unit and floor/ceiling unit. ) √ √ √
Fixed air swing Swing angle can be fixed according to user needs (This function is available in cassette type unit and floor/ceiling unit. ) √ √ √
Fan speed regulation Indoor unit has multiple kinds of fan speed, to satisfy different air volume demand √ √ √
Auto fan speed The unit can select fan speed automatically based on the set temperature √ √ √
Turbo fan speed Turbo fan speed, to satisfy large air volume demand √ √ √
Multiple modes of static pressure
By adjusting the mode of static pressure, the unit can cope with different engineering requirements. √
Drying mode
Drying mode The unit can run in drying mode. √ √ √
Low temperature drying Reliable drying at 12℃ √ √ √
Energy saving I-Demand After I-Demand mode is set, the unit can save 25% of power. √ √ √
Preview of Indoor Models
Functions of Indoor Units
09 10
Function Description Duct Type Cassette Type
Floor Ceiling Type
Smart control
WIFI & APP User can control the unit easily through an APP in a smart phone. √ √ √
Centralized controlCentralized control for 36 indoor units maximum. Basic controls include: On/Off, mode, fan speed, temperature, etc.MODBUS gateway required.
√ √ √
Long-distance control
The unit can be controlled remotely.Modbus gateway required. √ √ √
Modbus
Gateway interface module connecting the network of indoor units and the network of Modbus, for communication interchangeModbus gateway is equipped with 6-core communication wire before ex-factory, which is to be connected with the needle stand of the main board of indoor unitScrew terminal on Modbus gateway is connected to centralized controller/long-distance monitor
√ √ √
Dry contact
Through dry contact, gateway can activate simple control on the unit:Input signal: On/Off, mode (heating/not heating), fire alarmOutput signal: the state of power-on, running mode (heating/not heating), error outputEach input/output interface is dry contact interface
√ √ √
Access controlApplicable to hotels, etc. Pull the card to power off and insert the card to restore the condition before power is off; compatible both high and low current access control interfaces.
√ √ √
Double wired controllers
Double wired controllers can be set. They have the same functions and can be installed at the door and bedside, to provide convenient AC control. √ √ √
Programmable wired controller
LCD with white background and black words9 touch buttonsOne Time Clock Timer Daily TimerWeekly TimerTwo Week Timer Countdown Timer
√ √ √
Other functions
8℃ heating In winter, if you are away, the unit can maintain room temperature at 8℃ , to care for your pets and plants √ √ √
Power-off memory function
In case of power failure, unit will memorise the operating condition and restore the previous operating condition when power is resumed √ √ √
Malfunction self-diagnosis
The unit can diagnose the operating condition intelligently to prevent malfunctions. If malfunction occurs, error code will be displayed. √ √ √
Built-in water pump Built-in water pump with the lift reaching 1000mm (cassette type, duct type with water pump) √ √
One connected to two, three, four(under development)
One outdoor unit can be connected to 2, 3 or 4 sets of indoor units of the same cooling capacity and the same type √ √ √
Dual unit backup function(under development)
When one unit breaks down, the backup unit can start operation at once; when one unit cannot hold the demand, the backup unit can start working to supplement the output. √ √ √
Timer On/Off Timer mode is for users to preset the time for unit On/Off √ √ √
Ambient temperature inquiry
User can check indoor ambient temperature, outdoor ambient temperature and the set temperature through wired controller or remote controller √ √ √
System parameters inquiry
User can check parameters of sensors through the wired controller, which is convenient for maintenance √ √ √
Historical errors inquiry User can check historical errors through the wired controller to locate the error quickly √ √ √
● 360°air discharge for balance room temperature;
● Independent control for swing blade: each swing blade can control the swing angle independently(under development);
● Match with three kinds of panel: standard panel, air return lifting panel(applicable to model GUD**T/A-T[**: 71/85/100/125/140/160] only) and smart panel(under development);
● Lifting of air return frame can be controlled freely(optional);When matching with the air return lifting panel, the lifting of air return frame can be control freely, convenient for clean. The longest dropping distance of air return frame is 4m.
● Smart sensorDetect the personnel activity status in the room and then intelligently control the operation of air conditioner(under development);
● Selection of air return dual temperature sensors: Match with wired controller can select air return temperature sensor or wired controller temperature sensor as the indoor ambient temperature sensor for improving comfort;
● DC motor and DC water pump, energy-saving and high efficiency;
● Fresh air can be connected;
● Lift of water pump is 1000mm;
● Energy efficiency can be up to A++ in cooling season and A+ in heating season.
YAP1F6(Standard) XK75(Optional) XK117(Optional)
360° Air Discharge Cassette Unit
11 12
GUD**T/A-T+GUD**W/NhA-T 71 85 100 125 140
Capacity
CoolingkW 7.00 8.50 10.00 12.10 13.40
Btu/h 23800 29000 34100 41200 45700
HeatingkW 8.00 8.80 12.00 13.50 15.50
Btu/h 27200 30000 40900 46000 52800
SEER/SCOP - 7.2/3.9 6.1/4.0 6.1/4.0 6.1/3.8 6.1/3.6
Energy efficiency grade (Cooling/Heating) - A++/A A++/A+ A++/A+ A++/A A++/A
Power supply V/Hz/Ph
220-240/208-230-50/60-1
220-240/208-230-50/60-1
220-240/208-230-50/60-1
220-240/208-230-50/60-1
220-240/208-230-50/60-1
Power input
Cooling kW 2.05 2.80 3.15 4.10 4.65
Heating kW 2.20 2.65 3.55 4.20 4.35
Current input
Cooling A 8.8 12.7 13.8 17.5 20.8
Heating A 9.5 11.7 15.7 18 19.5
Refrigerant charge volume kg 1.6 1.8 2.5 2.65 2.8
Loading quantity 40’GP/40’HQ set 79/91 66/82 59/72 56/56 56/56
Indoor unit GUD**T/A-T 71 85 100 125 140
Air flow volume(SH/H/M/L)CFM 647/618/565/512 824/771/694/612 883/865/812/718 1059/995/865/742 1118/995/871/671
m³/h 1100/1050/960/870 1400/1310/1180/1040 1500/1470/1380/1220 1800/1690/1470/1260 1900/1690/1480/1140
ESPRated Pa - - - - -
Range Pa - - - - -
Sound pressure level(SH/H/M/L) dB(A) 43/42/40/39 49/47/44/41 50/48/46/42 51/49/46/42 52/51/48/45
Dimension (W×D×H)
Outline mm 840×840×240 840×840×240 840×840×240 840×840×290 840×840×290
Package mm 963×963×325 963×963×325 963×963×325 963×963×379 963×963×379
Net weight/Gross weight kg 29.0/36.0 29.0/36.0 31.0/38.0 33.0/41.0 36.0/44.0
Panel
Outline Dimension(W×D×H) mm 950×950×52 950×950×52 950×950×52 950×950×52 950×950×52
Package Dimension (W×D×H) mm 1033×1038×112 1033×1038×112 1033×1038×112 1033×1038×112 1033×1038×112
Net weight/Gross weight kg 6.0/9.5 6.0/9.5 6.0/9.5 6.0/9.5 6.0/9.5
Outdoor unit GUD**W/NhA-T 71 85 100 125 140
Sound pressure level dB(A) 52/—/— 53/—/— 55/—/— 55/—/— 56/—/—
Dimension (W×D×H)
Outline mm 892×340×698 920×370×790 940×460×820 940×460×820 940×460×820
Package mm 1029×458×750 1083×488×855 1083×573×973 1083×573×973 1083×573×973
Net weight/Gross weight kg 53.0/57.0 60.0/65.0 83.0/95.0 91.0/103.0 95.0/107.0
Connecting pipe
Outdoor diameter (Liquid pipe) inch 3/8" 3/8" 3/8" 3/8" 3/8"
Outdoor diameter (Gas pipe) inch 5/8" 5/8" 5/8" 5/8" 5/8"
Max. distance (Height/Length) m 25/50 25/50 30/65 30/75 30/75
GUD**T/A-T+GUD**W/NhA-X 100 125 140 160
Capacity
CoolingkW 10.00 12.10 13.40 14.50
Btu/h 34100 41200 45700 49400
HeatingkW 12.00 13.50 15.50 17.00
Btu/h 40900 46000 52800 58000
SEER/SCOP - 6.1/4.0 6.1/3.8 6.1/4.0 6.1/3.8
Energy efficiency grade (Cooling/Heating) - A++/A+ A++/A A++/A+ A++/A
Power supply V/Hz/Ph 380-415-50/60-3 380-415-50/60-3 380-415-50/60-3 380-415-50/60-3
Power input
Cooling kW 3.00 4.05 4.70 5.20
Heating kW 3.40 4.15 4.45 4.80
Current input
Cooling A 5.00 5.90 7.20 7.60
Heating A 5.30 6.10 6.20 7.20
Refrigerant charge volume kg 2.5 2.65 2.8 3.6
Loading quantity 40’GP/40’HQ set 59/72 56/56 56/56 47/50
Indoor unit GUD**T/A-T 100 125 140 160
Air flow volume(SH/H/M/L)CFM 883/865/812/718 1059/995/865/742 1118/995/871/671 1177/1106/953/842
m³/h 1500/1470/1380/1220 1800/1690/1470/1260 1900/1690/1480/1140 2000/1880/1620/1430
ESPRated Pa - - - -
Range Pa - - - -
Sound pressure level(SH/H/M/L) dB(A) 50/48/46/42 51/49/46/42 52/51/48/45 54/52/50/48
Dimension (W×D×H)
Outline mm 840×840×240 840×840×290 840×840×290 840×840×290
Package mm 963×963×325 963×963×379 963×963×379 963×963×379
Net weight/Gross weight kg 31.0/38.0 33.0/41.0 36.0/44.0 36.0/44.0
Panel
Outline Dimension(W×D×H) mm 950×950×52 950×950×52 950×950×52 950×950×52
Package Dimension (W×D×H) mm 1033×1038×112 1033×1038×112 1033×1038×112 1033×1038×112
Net weight/Gross weight kg 6.0/9.5 6.0/9.5 6.0/9.5 6.0/9.5
Outdoor unit GUD**W/NhA-X 100 125 140 160
Sound pressure level dB(A) 55/—/— 56/—/— 57/—/— 57/—/—
Dimension (W×D×H)
Outline mm 940×460×820 940×460×820 940×460×820 900×340×1345
Package mm 1083×573×973 1083×573×973 1083×573×973 1048×458×1500
Net weight/Gross weight kg 89.0/101.0 95.0/107.0 99.0/111.0 112.0/122.0
Connecting pipe
Outdoor diameter (Liquid pipe) inch 3/8" 3/8" 3/8" 3/8"
Outdoor diameter (Gas pipe) inch 5/8" 5/8" 5/8" 5/8"
Max. distance (Height/Length) m 30/65 30/75 30/75 30/75
13 14
● 360°air discharge;
● Width and length of case are only 570mm2 perfectly matching the ceiling;
● Selection of air return dual temperature sensors: Match with wired controller can select air return temperature sensor or wired controller temperature sensor as the indoor ambient temperature sensor for improving comfort;
● DC motor and DC water pump, energy-saving and high efficiency;
● Fresh air can be connected;
● Lift of water pump is 1000mm;
● Energy efficiency can be up to A++ in cooling season and A+ in heating season.
YAP1F6(Standard) XK75(Optional) XK117(Optional)
GUD**T/A-T+GUD**W/NhA-T 35 50
Capacity
CoolingkW 3.50 5.00
Btu/h 11900 17000
HeatingkW 4.00 5.50
Btu/h 13600 18700
SEER/SCOP - 5.9/4.0 5.9/4.0
Energy efficiency grade (Cooling/Heating) - A+/A+ A+/A+
Power supply V/Hz/Ph 220-240/208-230-50/60-1 220-240/208-230-50/60-1
Power inputCooling kW 1.00 1.56
Heating kW 1.05 1.65
Current inputCooling A 4.50 6.83
Heating A 4.70 7.24
Refrigerant charge volume kg 0.78 1
Loading quantity 40’GP/40’HQ set 130/162 130/162
Indoor unit GUD**T/A-T 35 50
Air flow volume(SH/H/M/L)CFM 382/341/282/235 412/341/282/235
m³/h 650/580/480/400 700/580/480/400
ESPRated Pa - -
Range Pa - -
Sound pressure level(SH/H/M/L) dB(A) 41/39/36/33 44/39/36/33
Dimension(WxDxH)Outline mm 570×570×265 570×570×265
Package mm 698×653×295 698×653×295
Net weight/Gross weight kg 17.0/22.0 17.0/22.0
Panel
Outline Dimension(WxDxH) mm 620×620×47.5 620×620×47.5
Package Dimension (WxDxH) mm 701×701×125 701×701×125
Net weight/Gross weight kg 3.0/4.5 3.0/4.5
Outdoor unit GUD**W/NhA-T 35 50
Sound pressure level dB(A) 50/—/— 53/—/—
Dimension(WxDxH)Outline mm 818×302×596 818×302×596
Package mm 948×420×645 948×420×645
Net weight/Gross weight kg 37.0/40.0 39.0/42.0
Connecting pipe
Outdoor diameter (Liquid pipe) inch 1/4" 1/4"
Outdoor diameter (Gas pipe) inch 3/8" 1/2"
Max. distance (Height/Length) m 15/30 20/35
Compact Cassette Unit
15 16
● Depth for 35 and 50 model is only 200mm;
● Depth for 71 and 85 model is only 220mm;
● Match with wired controller can adjust the static pressure mode for different engineering installation requirements;
● Selection of air return dual temperature sensors: Match with wired controller can select air return temperature sensor or wired controller temperature sensor as the indoor ambient temperature sensor for improving comfort;
● DC motor, energy-saving and high efficiency;
● Fresh air can be connected;
● Lift of water pump is 1000mm;
● Energy efficiency can be up to A++ in cooling season and A+ in heating season.
Ultra-thin Air Duct Unit GUD**P/A-T+GUD**W/NhA-T GUD**PS/A-T+GUD**W/NhA-T 35 50 71 85
Capacity
CoolingkW 3.50 5.00 7.00 8.50
Btu/h 11900 17000 23800 29000
HeatingkW 4.00 5.50 8.00 8.80
Btu/h 13600 18700 27200 30000
SEER/SCOP - 6.1/4.0 6.1/4.0 6.8/4.0 6.1/4.0
Energy efficiency grade (Cooling/Heating) - A++/A+ A++/A+ A++/A+ A++/A+
Power supply V/Hz/Ph 220-240/208-230-50/60-1 220-240/208-230-50/60-1 220-240/208-230-50/60-1 220-240/208-230-50/60-1
Power input
Cooling kW 0.95 1.55 2.10 2.70
Heating kW 1.05 1.45 2.25 2.55
Current input
Cooling A 4.18 6.30 8.70 12.10
Heating A 4.70 6.00 9.50 11.10
Refrigerant charge volume kg 0.78 1.00 1.60 1.80
Loading quantity 40’GP/40’HQ set 141/158 124/142 84/102 76/89
Indoor unit GUD**P/A-T (GUD**PS/A-T) 35 50 71 85
Air flow volume(SH/H/M/L)CFM 383/353/300/265 559/518/483/412 706/682/641/553 883/794/665/559
m³/h 650/600/510/450 950/880/820/700 1200/1160/1090/940 1500/1350/1130/950
ESPRated Pa 25 25 25 37
Range Pa 0-50 0-50 0-75 0-75
Sound pressure level(SH/H/M/L) dB(A) 41/38/36/34 43/42/39/36 40/39/37/36 42/40/37/35
Dimension (W×D×H)
Outline mm 700×450×200 1000×450×200 1300×450×220 1300×450×220
Package mm 1008×568×275 1308×568×275 1628x578x300 1628x578x300
Net weight/Gross weight kg19.0/23.0 25.0/30.0 30.0/37.0 30.0/37.0
20.0/24.0 26.0/31.0 31.0/38.0 31.0/38.0
Outdoor unit GUD**W/NhA-T 35 50 71 85
Sound pressure level dB(A) 50/—/— 53/—/— 52/—/— 53/—/—
Dimension (WxDxH)
Outline mm 818×302×596 818×302×596 892×340×698 920×370×790
Package mm 948×420×645 948×420×645 1029×458×750 1083×488×855
Net weight/Gross weight kg 37.0/40.0 39.0/42.0 53.0/57.0 60.0/65.0
Connecting pipe
Outdoor diameter (Liquid pipe) inch 1/4" 1/4" 3/8" 3/8"
Outdoor diameter (Gas pipe) inch 3/8" 1/2" 5/8" 5/8"
Max. distance (Height/Length) m 15/30 20/35 25/50 25/50
YAP1F6(Optional) XK75(Optional) XK117(Standard)
17 18
High Static Pressure Air Duct Unit
● Match with wired controller can adjust the static pressure mode for different engineering installation requirements;
● Selection of air return dual temperature sensors: Match with wired controller can select air return temperature sensor or wired controller temperature sensor as the indoor ambient temperature sensor for improving comfort;
● DC motor, energy-saving and high efficiency;
● Fresh air can be connected;
● Lift of water pump is 1000mm;
● Energy efficiency can be up to A++ in cooling season and A+ in heating season;
● Five static pressure modes for selection. The highest static pressure can be up to 200Pa.
GUD**PH/A-T+GUD**W/NhA-T GUD**PHS/A-T+GUD**W/NhA-T 100 125 140
Capacity
CoolingkW 10.00 12.10 13.40
Btu/h 34100 41200 45700
HeatingkW 12.00 13.50 15.50
Btu/h 40900 46000 52800
SEER/SCOP - 6.1/4.0 5.8/3.8 6.1/3.6
Energy efficiency grade (Cooling/Heating) - A++/A+ A+/A A++/A
Power supply V/Hz/Ph 220-240/208-230-50/60-1 220-240/208-230-50/60-1 220-240/208-230-50/60-1
Power inputCooling kW 3.20 4.10 4.45
Heating kW 3.40 4.10 4.60
Current input
Cooling A 13.90 17.90 19.90
Heating A 15.20 17.00 20.40
Refrigerant charge volume kg 2.5 2.65 2.8
Loading quantity 40’GP/40’HQ set 57/57 47/53 47/53
Indoor unit GUD**PH/A-T (GUD**PHS/A-T) 100 125 140
Air flow volume(SH/H/M/L)CFM 1059/894/812/747 1177/1018/924/824 1295/1177/1018/877
m³/h 1800/1520/1380/1270 2000/1730/1570/1400 2200/2000/1730/1490
ESPRated Pa 37 50 50
Range Pa 0-150 0-150 0-150
Sound pressure level(SH/H/M/L) dB(A) 46/44/42/40 42/40/39/37 43/41/40/38
Dimension (W×D×H)
Outline mm 1000×700×300 1400×700×300 1400×700×300
Package mm 1205×813×360 1601×813×365 1601×813×365
Net weight/Gross weight kg40.0/46.0 49.0/55.0 49.0/55.0
41.0/47.0 50.0/56.0 50.0/56.0
Outdoor unit GUD**W/NhA-T 100 125 140
Sound pressure level dB(A) 55/—/— 55/—/— 56/—/—
Dimension (WxDxH)
Outline mm 940×460×820 940×460×820 940×460×820
Package mm 1083×573×973 1083×573×973 1083×573×973
Net weight/Gross weight kg 83/95 91/103 95/107
Connecting pipe
Outdoor diameter (Liquid pipe) inch 3/8" 3/8" 3/8"Outdoor diameter (Gas pipe) inch 5/8" 5/8" 5/8"Max. distance (Height/Length) m 30/65 30/75 30/75
YAP1F6(Optional) XK75(Optional) XK117(Standard)
0219 20
GUD**PH/A-T+GUD**W/NhA-X GUD**PHS/A-T+GUD**W/NhA-X 100 125 140 160
Capacity
CoolingkW 10.00 12.10 13.40 16.00
Btu/h 34100 41200 45700 54500
HeatingkW 12.00 13.50 15.50 17.00
Btu/h 40900 46000 52800 58000
SEER/SCOP - 6.1/4.0 5.8/3.8 5.6/3.7 6.1/3.8
Energy efficiency grade (Cooling/Heating) - A++/A+ A+/A A+/A A++/A
Power supply V/Hz/Ph 380-415-50/60-3 380-415-50/60-3 380-415-50/60-3 380-415-50/60-3
Power input
Cooling kW 3.15 3.80 4.70 5.45
Heating kW 3.50 3.90 4.45 5.00
Current input
Cooling A 4.80 5.30 7.20 7.70
Heating A 5.60 5.50 6.20 7.30
Refrigerant charge volume kg 2.5 2.65 2.8 3.6
Loading quantity 40’GP/40’HQ set 57/56 47/53 47/53 43/47
Indoor unit GUD**PH/A-T (GUD**PHS/A-T) 100 125 140 160
Air flow volume(SH/H/M/L)CFM 1059/894/812/747 1177/1018/924/824 1295/1177/1018/877 1412/1153/983/812
m³/h 1800/1520/1380/1270 2000/1730/1570/1400 2200/2000/1730/1490 2400/1960/1670/1380
ESPRated Pa 37 50 50 50
Range Pa 0-150 0-150 0-150 0-200
Sound pressure level(SH/H/M/L) dB(A) 46/44/42/40 42/40/39/37 43/41/40/38 44/41/39/38
Dimension (W×D×H)
Outline mm 1000×700×300 1400×700×300 1400×700×300 1400×700×300
Package mm 1205×813×360 1601×813×365 1601×813×365 1678×808×365
Net weight/Gross weight kg40.0/46.0 49.0/55.0 49.0/55.0 56.0/63.0
41.0/47.0 50.0/56.0 50.0/56.0 57.0/64.0
Outdoor unit GUD**W/NhA-X 100 125 140 160
Sound pressure level dB(A) 55/—/— 56/—/— 57/—/— 57/—/—
Dimension (WxDxH)
Outline mm 940×460×820 940×460×820 940×460×820 900×340×1345
Package mm 1083×573×973 1083×573×973 1083×573×973 1048×458×1500
Net weight/Gross weight kg 89.0/101.0 95.0/107.0 99.0/111.0 112.0/122.0
Connecting pipe
Outdoor diameter (Liquid pipe) inch 3/8" 3/8" 3/8" 3/8"
Outdoor diameter (Gas pipe) inch 5/8" 5/8" 5/8" 5/8"
Max. distance (Height/Length) m 30/65 30/75 30/75 30/75
Floor Ceiling Unit
● Selection of air return dual temperature sensors: Match with wired controller can select air return temperature sensor or wired controller temperature sensor as the indoor ambient temperature sensor for improving comfort;
● DC motor, energy-saving and high efficiency;
● Fresh air can be connected;
● Energy efficiency can be up to A++ in cooling season and A+ in heating season.
YAP1F6(Standard) XK75(Optional) XK117(Optional)
21 22
GUD**ZD/A-T+GUD**W/NhA-T 100 125 140
Capacity
CoolingkW 10.00 12.10 13.40
Btu/h 34100 41200 45700
HeatingkW 12.00 13.50 15.50
Btu/h 40900 46000 52800
SEER/SCOP - 6.1/4.0 6.1/3.8 6.1/3.7
Energy efficiency grade (Cooling/Heating) - A++/A+ A++/A A++/A
Power supply V/Hz/Ph 220-240/208-230-50/60-1 220-240/208-230-50/60-1 220-240/208-230-50/60-1
Power input
Cooling kW 3.30 3.90 4.40
Heating kW 3.60 3.95 4.35
Current input
Cooling A 14.50 15.70 19.50
Heating A 15.90 16.80 19.40
Refrigerant charge volume kg 2.5 2.65 2.8
Loading quantity 40’GP/40’HQ set 57/68 54/62 54/62
Indoor unit GUD**ZD/A-T 100 125 140
Air flow volume(SH/H/M/L)CFM 942/883/794/742 1059/1000/906/824 1236/1177/1059/871
m³/h 1600/1500/1350/1260 1800/1700/1540/1400 2100/2000/1800/1480
ESPRated Pa - - -
Range Pa - - -
Sound pressure level(SH/H/M/L) dB(A) 49/47/45/43 49/47/44/42 52/50/48/44
Dimension (W×D×H)
Outline mm 1200×665×235 1570×665×235 1570×665×235
Package mm 1363×770×300 1729×770×300 1729×770×300
Net weight/Gross weight kg 32.0/38.0 40.0/47.0 42.0/49.0
Outdoor unit GUD**W/NhA-T 100 125 140
Sound pressure level dB(A) 55/—/— 55/—/— 56/—/—
Dimension (WxDxH)
Outline mm 940×460×820 940×460×820 940×460×820
Package mm 1083×573×973 1083×573×973 1083×573×973
Net weight/Gross weight kg 83.0/95.0 91.0/103.0 95.0/107.0
Connecting pipe
Outdoor diameter (Liquid pipe) inch 3/8" 3/8" 3/8"
Outdoor diameter (Gas pipe) inch 5/8" 5/8" 5/8"
Max. distance (Height/Length) m 30/65 30/75 30/75
GUD**ZD/A-T+GUD**W/NhA-T 35 50 71 85
Capacity
CoolingkW 3.50 5.00 7.00 8.50
Btu/h 11900 17000 23800 29000
HeatingkW 4.00 5.50 8.00 8.80
Btu/h 13600 18700 27200 30000
SEER/SCOP - 6.7/4.0 6.1/4.0 6.8/3.9 6.1/4.0
Energy efficiency grade (Cooling/Heating) - A++/A+ A++/A+ A++/A A++/A+
Power supply V/Hz/Ph 220-240/208-230-50/60-1 220-240/208-230-50/60-1 220-240/208-230-50/60-1 220-240/208-230-50/60-1
Power input
Cooling kW 0.90 1.55 1.90 2.80
Heating kW 0.95 1.60 2.45 2.65
Current input
Cooling A 4.00 6.50 8.60 12.70
Heating A 4.20 6.90 10.50 11.70
Refrigerant charge volume kg 0.78 1.00 1.60 1.80
Loading quantity 40’GP/40’HQ set 114/132 114/132 90/97 74/86
Indoor unit GUD**ZD/A-T 35 50 71 85
Air flow volume(SH/H/M/L)CFM 383/359/312/271 500/471/412/353 765/718/641/553 883/812/706/600
m³/h 650/610/530/460 850/800/700/600 1300/1220/1090/940 1500/1380/1200/1020
ESPRated Pa - - - -
Range Pa - - - -
Sound pressure level(SH/H/M/L) dB(A) 39/36/32/28 44/42/39/36 45/44/41/38 49/47/43/39
Dimension (W×D×H)
Outline mm 870×665×235 870×665×235 1200×665×235 1200×665×235
Package mm 1033×770×300 1033×770×300 1363×770×300 1363×770×300
Net weight/Gross weight kg 25.0/30.0 26.0/31.0 31.0/37.0 31.0/37.0
Outdoor unit GUD**W/NhA-T 35 50 71 85
Sound pressure level dB(A) 50/—/— 53/—/— 52/—/— 53/—/—
Dimension (WxDxH)
Outline mm 818×302×596 818×302×596 892×340×698 920×370×790
Package mm 948×420×645 948×420×645 1029×458×750 1083×488×855
Net weight/Gross weight kg 37.0/40.0 39.0/42.0 53.0/57.0 60.0/65.0
Connecting pipe
Outdoor diameter (Liquid pipe) inch 1/4" 1/4" 3/8" 3/8"
Outdoor diameter (Gas pipe) inch 3/8" 1/2" 5/8" 5/8"
Max. distance (Height/Length) m 15/30 20/35 25/50 25/50
23 24
Wall-mounted Unit
● Selection of air return dual temperature sensors: Match with wired controller can select air return temperature sensor or wired controller temperature sensor as the indoor ambient temperature sensor for improving comfort;
● DC motor, energy-saving and high efficiency;
● Energy efficiency can be up to A++ in cooling season and A+ in heating season.
YAP1F6(Standard) XK75(Optional) XK117(Optional)
GUD**ZD/A-T+GUD**W/NhA-X 100 125 140 160
Capacity
CoolingkW 10.00 12.10 13.40 16.00
Btu/h 34100 41200 45700 54500
HeatingkW 12.00 13.50 15.50 17.00
Btu/h 40900 46000 52800 58000
SEER/SCOP - 6.1/4.0 6.1/3.8 6.1/4.0 6.1/4.0
Energy efficiency grade (Cooling/Heating) - A++/A+ A++/A A++/A+ A++/A
Power supply V/Hz/Ph 380-415-50/60-3 380-415-50/60-3 380-415-50/60-3 380-415-50/60-3
Power input
Cooling kW 3.30 4.05 4.30 5.40
Heating kW 3.50 4.00 4.40 5.40
Current input
Cooling A 5.10 5.90 6.60 7.70
Heating A 5.60 6.10 6.70 7.60
Refrigerant charge volume kg 2.50 2.65 2.8 3.6
Loading quantity 40’GP/40’HQ set 57/68 54/62 54/62 46/55
Indoor unit GUD**ZD/A-T 100 125 140 160
Air flow volume(SH/H/M/L)CFM 942/883/794/742 1059/1000/906/824 1236/1177/1059/871 1354/1295/1100/936
m³/h 1600/1500/1350/1260 1800/1700/1540/1400 2100/2000/1800/1480 2300/2200/1870/1590
ESPRated Pa - - - -
Range Pa - - - -
Sound pressure level(SH/H/M/L) dB(A) 49/47/45/43 49/47/44/42 52/50/48/44 54/53/49/45
Dimension (WxDxH)
Outline mm 1200×665×235 1570×665×235 1570×665×235 1570×665×235
Package mm 1363×770×300 1729×770×300 1729×770×300 1729×770×300
Net weight/Gross weight kg 32.0/38.0 40.0/47.0 42.0/49.0 42.0/49.0
Outdoor unit GUD**W/NhA-X 100 125 140 160
Sound pressure level dB(A) 55/—/— 56/—/— 57/—/— 57/—/—
Dimension (WxDxH)
Outline mm 940×460×820 940×460×820 940×460×820 900×340×1345
Package mm 1083×573×973 1083×573×973 1083×573×973 1048×458×1500
Net weight/Gross weight kg 89.0/101.0 95.0/107.0 99.0/111.0 112.0/122.0
Connecting pipe
Outdoor diameter (Liquid pipe) inch 3/8" 3/8" 3/8" 3/8"
Outdoor diameter (Gas pipe) inch 5/8" 5/8" 5/8" 5/8"
Max. distance (Height/Length) m 30/65 30/75 30/75 30/75
25 26
Note: The model GUD71G/A-T and model GUD100G/A-T are under development. Please confirm the final specifications with our sales representatives.
GUD**G/A-T+GUD**W/NhA-T 71 100
Capacity
CoolingkW 6.5 9.5
Btu/h 22000 32000
HeatingkW 7.5 10.5
Btu/h 25600 35800
SEER/SCOP - 6.1/4.1 6.1/4.1
Energy efficiency grade (Cooling/Heating) - A++/A+ A++/A+
Power supply V/Hz/Ph 220-240/208-230-50/60-1
Power inputCooling kW 2.1 3.2
Heating kW 2.25 3.4
Current inputCooling A 8.7 12.1
Heating A 9.5 9.5
Refrigerant charge volume kg 1.6 2.5
Loading quantity 40’GP/40’HQ set 118/131 72/87
Indoor unit GUD**G/A-T 71 100
Air flow volume(SH)CFM 735 941
m³/h 1250 1600
ESPRated Pa - -
Range Pa - -
Sound pressure level(SH/H/M/L) dB(A) 44 50
Dimension (WxDxH)
Outline mm 1078x246x325 1350x253x326
Package mm 1148x413x350 1441x421x367
Net weight/Gross weight kg 16/20 19/24
Outdoor unit GUD**W/NhA-T 71 100
Sound pressure level dB(A) 52 55
Dimension (WxDxH)
Outline mm 892x340x698 940x460x820
Package mm 1029x458x750 1073x563x868
Net weight/Gross weight kg 53/57 83/95
Connecting pipe
Outdoor diameter (Liquid pipe) inch 3/8” 3/8”
Outdoor diameter (Gas pipe) inch 5/8” 5/8”
Max. distance (Height/Length) m 50/75 65/75
Floor Standing Unit
YAP1F6(Standard) XK75(Optional) XK117(Optional)
● Selection of air return dual temperature sensors: Match with wired controller can select air return temperature sensor or wired controller temperature sensor as the indoor ambient temperature sensor for improving comfort;
● Energy efficiency can be up to A++ in cooling season and A+ in heating season.
27 28
Note: The model from GUD71L/A-T to GUD140L/A-T are under development. Please confirm the final specifications with our sales representatives.
29 30
GUD**L/A-T+GUD**W/NhA-T 71 100 125 140
Capacity
CoolingkW 7 10 12 13.4
Btu/h 24000 34100 41000 45700
HeatingkW 8 12 13.5 16
Btu/h 27000 41000 46000 55000
SEER/SCOP - 6..1/4.0 6.1/4.0 6.1/4.0 6.1/4.0
Energy efficiency grade (Cooling/Heating) - A++/A+ A++/A+ A++/A+ A++/A+
Power supply V/Hz/Ph 220-240/208-230-50/60-1
Power inputCooling kW 2.1 3.2 4.1 4.65
Heating kW 2.25 3.4 4.1 4.35
Current inputCooling A 8.7 13.9 17.9 19.5
Heating A 9.5 15.2 17 19.4
Refrigerant charge volume kg 1.6 2.5 2.65 2.8
Loading quantity 40’GP/40’HQ set 47/47 36/42 36/42 36/42
Indoor unit GUD**L/A-T 71 100 125 140
Air flow volume(SH)CFM 647 970 970 1058
m³/h 1100 1650 1650 1800
ESPRated Pa - - - -
Range Pa - - - -
Sound pressure level(SH) dB(A) 54 56 56 58
Dimension (WxDxH)
Outline mm 1870x580x395 1870x580x395 1870x580x395 1870x580x395
Package mm 2153x738x545 2153x738x545 2153x738x545 2153x738x545
Net weight/Gross weight kg 56/63 56/63 59/66 59/66
Outdoor unit GUD**W/NhA-T 71 100 125 140
Sound pressure level dB(A) 52 55 55 56
Dimension (WxDxH)
Outline mm 892x340x698 940x460x820 940x460x820 940x460x820
Package mm 1029x458x750 1073x563x868 1073x563x868 1073x563x868
Net weight/Gross weight kg 53/57 83/95 91/103 95/107
Connecting pipe
Outdoor diameter (Liquid pipe) inch 3/8” 3/8” 3/8” 3/8”
Outdoor diameter (Gas pipe) inch 5/8” 5/8” 5/8” 5/8”
Max. distance (Height/Length) m 25/50 30/65 30/75 30/75
BMScentralized controller
BMScommunication network
Modbus Gateway
Indoor unit1 Indoor unit2 Indoor unit255
RS485communication network
Master wired controller
Slave wired controller
Outdoor unit WIFI module
Two-core communication interface Main board of indoor unit supply 12VFour-core communication interface
Dry contact gateway
Modbus Gateway
Modbus Gateway
Control Network1
Control System
Model:CE52–24/F(C)
Dimension(H×W×D):128.2mm×185.2mm×54mm
● Centralized control function: up to 36 indoor units can be controlled.
● Basic control for the unit: ON/OFF, mode, fan, temperature and so on.
● Equipped with MODBUS gateway for operation.
Mobile network
2
3
APP and WIFI
Centralized Control
31 32
Model:ME50-00/EG(M) Dimension(H×W×D):54mm×102mm×20mm
● Gateway interface module connected indoor unit network and Modbus network for realizing communication switchover.
● Connect the ex-factory standard 6-core communication wire of Modbus gateway with the needle stand on the main board of indoor unit.
● Connect the screw terminal of Modbus gateway with the centralized controller/long-distance monitor.
The unit can select modbus gateway (long-distance monitor ME50-00/EG(M)) to connect to the BMS control system. One network can connect up to 255 devices.
Remote Control
Modbus Gateway
4
5
Dual wired controllers’ configuration can be realized by setting: wired controllers can be installed at the doorway and the bedside, for convenient operation.
Model:MK03
● It’s applicable for hotel and other places. Pull out the card to turn off the unit; insert the card to resume previous operation status.
● Compatible with both high and low current access control interfaces.
Model: ME30-42/E1Simple control for the unit can be realized through the dry contact gateway.
● Input signal: ON/OFF, mode (heating/non-heating), fire signal and force off signal;
● Output signal: on status, operation mode (heating/non-heating), error output; cold plasma output and ventilation output;
● All input and output are interface of dry contact.
● LCD with white background and black text● 8 touch buttons● Fahrenheit/Celsius● Swing fuction● I-demand function● Sleep function
Model:XK117Dimension(H×W×D):86mm×86mm×13mmFeatures:
Model:XK75Dimension(H×W×D):112mm×112mm×17mmFeatures:● LCD with white background and black text● 9 touch buttons● One Time Clock Timer ● Daily Timer● Weekly Timer● Two Week Timer ● Countdown Timer
Dual Wired Controllers6
7
8
9 10
Dry Contact
Access Control
Programmable Wired Controller Wired Controller
33 34
Note
Note
35 36