Home Inspection Report
**** Pine St, North Bend, OR 97459
Inspection Date:Tuesday December 4, 2018
Prepared For:Jerry and Shirlee M.
Prepared By:Hutchs Custom Homes
49531 Highway 101Bandon, OR 97411
(541) [email protected]
Report Number:****1
Inspector:Steve Hutchinson
License/Certification #:OR--1979
THIS REPORT IS INTENDED ONLY FOR THE USE OF THE PERSON PURCHASING THE HOME INSPECTION SERVICES. NO OTHER PERSON, INCLUDING A PURCHASER OF THE INSPECTED PROPERTY WHO DID NOT PURCHASE THE HOME INSPECTION SERVICES, MAY RELY UPON ANY REPRESENTATION MADE IN THE REPORT.
**** Pine St, North Bend, OR 97459 Page 2
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
Report SummaryTable Of Contents
• 2 Summary • 4 O verview • 6 House In Perspective • 7 Structure • 8 Roofing • 10 Exterior • 15 Electrical • 18 Heating/Cooling • 20 Insulation/Ventilation • 22 Plumbing • 24 Interior • 26 Appliance
Major Concerns• N one apparent
Potential Safety Hazards• S afety Issue: Consider installing more ground fault circuit interrupter (GFCI) outlets.(no exterior Gfci present) 16 • S afety Issue: An outlet has reversed polarity (i.e. it is wired backwards). 16
Repair Items• R epair: Debris should be removed from the roofing to reduce risk of leaks and early roof wear. 8 • R epair: Localized rot was observed in the wall coverings(trim) in one or more areas. 10 • Repair: Siding damage was observed in one area 10 • R epair: There was damage/decay observed near the bottom of one or more doors/door frames. 11 • Repair: One or more In wall heaters were inoperative with normal controls 18 • R epair: Loose or damaged insulation in the floor above the crawl space should be improved. 20 • R epair: The trap is leaking under the downstairs East bathroom vanity. 23 • R epair: The back right burner on the gas range is inoperative. 26
Improvement Items• Improve : The roofing shows evidence of moss and organic build up. 8 • Improve: Downspout(s) that discharge onto the roof should be extended to discharge directly into the gutters below. 9 • Improve: Keep up on all exterior touch-up caulking and painting to extend life spans of trim and siding 10 • Improve: One or more fence gates need adjustment. 13
Items To Monitor• Monitor: Typical driveway cracks were observed 12 • Mo nitor: The retaining wall shows evidence of movement. 13 • Monitor: There is low clearance in the crawlspace(less than 24 inches) 13 • M onitor: Forced air systems should be regularly serviced. 18 • M onitor: Pellet stove pilot was not lit during inspection. 18 • M onitor: Minor cracks in the drywall were noted. 24 • M onitor: The home exhibits several cosmetic deficiencies that may warrant interior components that need
cleaned/repaired/replaced. 25
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 3
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
Report SummaryDiscretionary Improvements
• Discretionary Improvement: Be sure to keep up on all exterior Caulking and touch up painting 14 • Discretionary Improvements: Consider adding a surge protector to the main panel to protect electronics 17 • Discretionary Improvement: Install new exterior lock sets upon taking possession of the home. 25
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 4
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
Report OverviewScope of Inspection
All components designated for inspection in the ASHI Standards of Practice are inspected, except as may be noted in the "Limitations of Inspection" sections within this report.
It is the goal of the inspection to put a home buyer in a better position to make a buying decision.
Not all improvements will be identified during this inspection.
Unexpected repairs should still be anticipatedhe inspection should not be considered a guarantee or warranty of any kind
Please refer to the pre-inspection contract for a full explanation of the scope of the inspection.
• V isual Inspection Only
Main Entrance Faces• E ast
Age of Home• 1976
Type Of Home• S ingle Family
Size• 3576 sq ft.
Bed/Baths• 4 Bed • 4 Bath
Parking• Attached Garage
State of Occupancy• O ccupied
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 5
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
Report OverviewWeather Conditions
• C loudy
Recent Rain• Y es
Ground Cover• D amp
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 6
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
House in PerspectiveDescription
Description • This home appears to have been well built and maintained. • Please remember that there is no such thing as perfect home.
Observations
Observations This inspection is visual only. A representative sample of building components are viewed in areas that are accessible at the time of the inspection. No destructive testing or dismantling of building components is performed.
Limitations
Weather conditions Dry weather conditions prevailed at the time of the inspection. The estimated outside temperature was 55 degrees F.
Recent weather conditions Occasional rain has been experienced in the days leading up to the inspection.
Limitations • Crawlspace may have not been fully inspected due to low clearance /poor access
Comments
Comments For the purpose of this report, it is assumed that the house faces east.
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 7
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
StructureDescription
Foundation • Poured Concrete • Crawl Space Configuration
Floor Structure • Wood • Joists • Beams
Wall Structure • Wood Frame • Not visible
Ceiling Structure • Joist • Truss
Roof Structure • R afters • R oof Joists • Engineered Tr usses • Stick Framed
Observations
Foundations • No significant defects observed
Floor Structure • There were no significant defects observed
Wall Structure • No significant defects observed
Roof Structure • No significant defects observed
Wood boring insects • There was no evidence of wood destroying insect damage observed at time of inspection • Not all areas of home may have been inspected do to site conditions
Discretionary improvements • None recommended
Limitations
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. • Please see standard of practice for full scope of exclusions and limitations • The crawl space inspection was limited by height restriction/obstructions.
Comments
Positive attributes The construction of the home is good quality. The materials and workmanship, where visible, are good. The visible joist spans appear to be within typical construction practices. The inspection did not discover evidence of substantial structural movement.
General comments • N o significant defects were observed in the accessible structural components of the house.
• Some areas may not have been inspected due to restricted access
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 8
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
RoofingDescription
Roof covering • Asphalt Shingle • 30 Yr.
Roof flashings • Metal
Chimneys • 2 • Masonry • Wood Chase • Flashings OK • Caps OK
Roof drainage system • D ischarge above & below grade
Skylight • 5 • Curb-Type • Flashings OK • Seals OK
Method of inspection • Walked on roof
Observations
Sloped • Improve : The roofing shows evidence of moss and organic build up . This condition may reduce the life expectancy of the roofing. • Adding copper or zinc strips will help discourage moss growth. • R epair: Debris should be removed from the roofing to reduce risk of leaks and early roof wear.
Photos
Fascias/Eaves • No significant defects observed
Flashings • No significant defects observed
Skylight • No significant defects observed
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 9
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
Roofing
Observations cont.
Chimney • No significant defects observed
Gutters & downspouts• Improve: Downspout(s) that discharge onto the roof should be extended to discharge directly
into the gutters below. This condition, if left unattended, can result in premature deterioration of the roofing under the end of the downspout.
Photos
Discretionary improvements • None recommended
Limitations
• P lease also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. • See ASHI standards of practice for further exclusions and limitations of inspection
Comments
Positive attributes • T he roof coverings appear to be in generally good condition. • G ood quality materials have been employed as roof coverings.
The installation of the roofing materials has been performed in a professional manner. Roof flashing details appear to be in good order. The chimneys do not show signs of significant deterioration.
General comments • I n all, the roof coverings show evidence of normal wear and tear for a home of this age. • Clean gutters regularly to prevent clogging • Roof coverings should last for many years with regular inspections and proper maintenance
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 10
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
ExteriorDescription
Wall covering • Fibered Cement Lap Siding • Fibered Cement Shingles
Eaves / Soffits / Fascias • Soffit appear to be LP
• Spruce Fascias
Doors • Solid Wood • Composite /Fiberglass
Windows • Vinyl Double Pane • Aluminum • Single pane
Entry driveways • Concrete
Entry walkways and patios • Concrete • Pavers • Stone
Porch / deck / steps / railings • Concrete
Overhead garage door(s) • 2 • Steel • Automatic Opener Installed • All Tests OK
Surface drainage • Level Grade • Graded Away From House
Retaining walls • Wood • Block
Fencing • Cedar • PT Framing • Vinyl
Crawlspace • Access Location: Interior hall closet
Sheds/Outbuildings • Tool Shed
Observations
Wall Coverings • R epair: Localized rot was observed in the wall coverings(trim) in one or more areas. -Repairs should be relatively inexpensive. -Localized rot of trims generally does not pose a leak risk. • Improve: Keep up on all exterior touch-up caulking and painting to extend life spans of trim and
siding • Repair: Siding damage was observed in one area
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 11
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
Exterior
Observations cont.
Photos
Southwest corner of home Rock damaged siding Garage window
Flaking paint overhead garage door
Eaves/ Soffits/ Fascias • No significant defects observed
Doors • R epair: There was damage/decay observed near the bottom of one or more doors/door frames. • Repairs and/or refinishing is needed.
Photos
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 12
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
Exterior
Windows • No significant defects were observed
Driveway • Monitor: Typical driveway cracks were observed • They should be monitored for further settlement/shrinkage. • Patch cracks to help prevent further water penetration/damage.
Photos
Walkway • No significant defects observed
Porch • No significant defects observed
Decks • N/A
Garage • No significant defects observed
Lot drainage • No significant defects observed
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 13
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
Exterior
Observations cont.
Retaining wall • Mo nitor: The retaining wall shows evidence of movement. This condition should be monitored. It is impossible to determine the rate of movement during a one time visit to the house. -It is likely the movement is old and now stabilized. -If further movement is observed, excavating behind the wall and adding better drainage may be advisable.
Photos
Fence • Improve: One or more fence gates need adjustment. • It did not open.
Photos
Crawlspace • Monitor: There is low clearance in the crawlspace(less than 24 inches) • Not all areas may have been inspected.
Outbuildings • No significant defects observed
Exterior Pests • There was no evidence of active wood destroying organisms present at time of inspection.
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 14
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
Exterior
Observations cont.
Discretionary improvements • Discretionary Improvement: Be sure to keep up on all exterior Caulking and touch up painting • This will help extend life spans of siding and trims
Limitations
• There was a reduced presence of historical evidence due to the installation of new siding over old siding. • Storage in the garage restricted the inspection.
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. • See ASHI standards of practice for full limitations and exclusions of exterior inspection
Comments
Positive attributes • The exterior paint appears to be in good condition. Window frames are clad, for the most part, with a low maintenance material. Soffit/Fascia Low Maintenance There is no significant wood/soil contact around the perimeter of the house, thereby reducing the risk of insect infestation or rot. The auto reverse mechanism on the overhead garage door responded properly to testing. This safety feature should be tested regularly as a door that doesn't reverse can injure someone or fall from the ceiling. Refer to the owner's manual or contact the manufacturer for more information. The lot drainage was good, conducting surface water away from the building.
General comments The exterior of the home is generally in good condition. The exterior of the home shows normal wear and tear for a home of this age.
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 15
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
ElectricalDescription
Size of service • 200 Amp 120/240v Main Service
Service drop • Overhead
Service entrance conductors • Aluminum
Serv. panel / current protect. • Panel Rating: 200 Amp • Breakers • Located: Exterior South wall
Photos
Sub-panel(s) • Panel Rating: 50 Amp • Breakers • Located: Exterior South side • Panel Rating: 200 Amp • Breakers • Located: Interior hallway
Photos
Service grounding • Copper • Ground Rod Connection • Ground Connection Not Visible
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 16
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
Electrical
Description cont.
Distribution wiring • Copper
Wiring Type(s) • Non-Metallic Sheathed Cable "Romex"
Switches / receptacles • Grounded
Ground fault circuit interrupter • Bathroom(s) • Kitchen
Observations
Safety notice • All electrical repairs should be done by a licensed electrician for safety.
Service / entrance • No significant defects observed
Main panel • No significant defects observed
Auxiliary panel(s) • No significant defects observed
Distribution wires • No significant defects observed
Aluminum wiring • No significant defects observed
Outlet • S afety Issue: Consider installing more ground fault circuit interrupter (GFCI) outlets.(no exterior Gfci present) • Install them within 6 feet of all "wet" locations
A GFCI offers increased protection from shock or electrocution.
• S afety Issue: An outlet has reversed polarity (i.e. it is wired backwards). This outlet and the circuit should be investigated and repaired as necessary.
Photos
By hot tub sub panel
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 17
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
Electrical
Observations cont.
Switches • No significant defects observed
Lights • No significant defects observed
Discretionary improvements • Discretionary Improvements: Consider adding a surge protector to the main panel to protect electronics • https://blog.happyhiller.com/blog/whole-house-surge-protection-lightning-storm-tips
Limitations
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. • See Ashi standards of practice for limitations and exclusions of inspection • Not all fixtures could be tested due to bad bulbs
Comments
Positive attributes The size of the electrical service is sufficient for typical single family needs. Panel Good / Fusing OK Generally speaking, the electrical system is in good order. Outlets / Switches OK The distribution of electricity within the home is good. All 3-prong outlets that were tested were appropriately grounded.
Gfci • Safety issue: consider adding GFCI protected Outlets to all receptacles within 6 ft of wet areas
General comments • I nspection of the electrical system revealed the need for typical, minor repairs. Although these are not costly to repair, they should be high priority for safety reasons. Unsafe electrical conditions represent a shock hazard. A licensed electrician should be consulted to undertake all repairs.
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 18
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
Heating/CoolingDescription
Energy source • Gas
Wood (pellets)
System type • Forced Air Furnace • Manufacturer: Rheem • Serial #: W211323434 • Age:2013 - 5 yrs(avg. Lifespan 15-25 yrs.) *many last much longer depending on
conditions and frequency of maintenance • Pellet Stove
• The in wall electric heaters have been disconnected
Vents / flues / chimneys • Metal-Multi Wall • Plastic
Heat distribution methods • Ductwork • Ductless
Other components • Condensate Pump(for furnace)
Observations
Furnace • M onitor: Forced air systems should be regularly serviced. This should be a regular maintenance item to assure safe, reliable service.
In-wall Heaters • Repair: One or more In wall heaters were inoperative with normal controls They appear to be disconnected fron power
Fireplaces • No significant defects observed
M onitor: Pellet stove pilot was not lit during inspection. The blower and auger functioned normally. Have pellet stove serviced before closing to assure safe, reliable service.
Supply air ductwork • No significant defects observed
Return air ductwork • No significant defects observed
Combustion / exhaust • No significant defects observed
Thermostat • No significant defects observed
Discretionary improvements • N/A
Conversion considerations • N/A
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 19
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
Heating/CoolingLimitations
• The furnace heat exchanger could not be inspected. • Recommend having exchanger periodically inspected for safety.
Comments
Positive attributes This is a high efficiency heating system. Heating a home with this type of heating system should be relatively economical. Adequate heating capacity is provided by the system. Heat distribution within the home is adequate. • All tested heaters ok.
General comments The heating system shows no visible evidence of significant defects.
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 20
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
Insulation/VentilationDescription
Attic • Fiberglass batts where observed • Blow In
Roof cavity • N/A
Exterior wall • Not Visible
Basement wall • N/A
Crawl space • R20+ in Floor above Crawl Space
Floor cavity • N/A
Vapor retarders • Plastic • On crawl floor
Roof ventilation • Roof Vents • Soffit Vents
Crawl space ventilation • Exterior Wall Vents
Exhaust fan/vent locations Bathrooms • Kitchen • Dryer
Observations
Attic / roof • No significant defects observed
Walls • No significant defects observed
Floors • No significant defects observed
Basement • N/A
Crawl space improvement • R epair: Loose or damaged insulation in the floor above the crawl space should be improved.
Exhaust Ventilation • No significant defects observed
Limitations
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. • Please refer to Ashi standards of practice for limitations and exclusions of inspection • The attic was viewed from the access hatch only. • The crawl space was viewed from the access hatch with digital imagery as far as I couod reach with 10 ft
pole.
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 21
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
Insulation/Ventilation
Limitations cont.
Comments
Positive attributes This appears to be a well insulated home.
General comments Caulking and weather-stripping around doors, windows and other exterior wall openings will help to maintain weather tightness and reduce energy costs. Upgrading insulation levels in a home is an improvement rather than a necessary repair.
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 22
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
PlumbingDescription
Water supply source • Public Water Supply
Service pipe to house • Steel
Main water valve location • In meter housing
Interior supply piping • Copper
Waste system • Public Sewer System
Drain / waste / vent piping • ABS
Water heater • Gas • Manufacturer: Reliance • Capacity: 50 gallons • Serial #: 1542J008965 • Age:2015 - 3Yrs(avg. Lifespan 10-14 yrs.)*Many last much longer depending on
conditions
Fuel shut-off valves • Natural Gas Main Valve At Meter • At appliances
Photos
Other components • N/A
Observations
Water heater unit • No significant defects observed
Gas piping • No significant defects observed
Supply • No significant defects observed
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 23
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
Plumbing
Observations cont.
Waste / vent • R epair: The trap is leaking under the downstairs East bathroom vanity.
Photos
Fixtures • No significant defects observed
Discretionary improvements • N/A
Limitations
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. • Please refer to ASHI standards of practice for exclusion limitations of inspection
Comments
Positive attributes The water pressure supplied to the fixtures is reasonably good. A typical drop in flow was experienced when two fixtures were operated simultaneously. The water heater is a relatively new unit. As the typical life expectancy of water heaters is 7 to 12 years, this unit should have several years of remaining life.
General comments The plumbing system requires some typical minor improvements. • T he water heater temperature should be set such that accidental scalding is minimized. Families
with small children should be especially aware of this.
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 24
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
InteriorDescription
Wall/ceiling materials • Drywall
Floor surfaces • Carpet • Tile • Wood
Doors • Wood • Hollow Core
Kitchen • Gas Range • Garbage disposal • Exterior venting for range • Dishwasher
Smoke/CO Detectors • Smoke detectors Present in bedrooms and hallways • Carbon Monoxide detectors present in hallways
Observations
Wall / ceiling finishes • M onitor: Minor cracks in the drywall were noted. • There was no evidence of significant structural issues. • Drywall cracks are very common in vault ceiling applications.
Photos
Floors • No significant defects observed
Windows • No significant defects observed
Door • No significant defects observed
Bedrooms • No significant defects observed
Bathrooms • No significant defects observed
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 25
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
Interior
Observations cont.
Kitchen • No significant defects observed
Laundry • No significant defects observed
Smoke/ CO Detectors • No significant defects observed
Interior Pest • No Evidence of Wood destroying Organisms observed at time of inspection
Discretionary improvements • Discretionary Improvement: Install new exterior lock sets upon taking possession of the home. • M onitor: The home exhibits several cosmetic deficiencies that may warrant interior
components that need cleaned/repaired/replaced.
Photos
Floor trim Bad drywall tape
Limitations
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. • See ASHI standards of practice for limitations and exclusions of inspection
Comments
Condition of finishes On the whole, the interior finishes of the home are in above average condition. Typical minor flaws were observed in some areas.
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 26
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
ApplianceDescription
Appliances tested • Gas Range • Microwave Oven • Dishwasher • Waste Disposer
Laundry facility • 240 Volt Circuit for Dryer • Gas Piping for Dryer • Dryer Vented to Building Exterior • 120 Volt Circuit for Washer • Hot/Cold Water Supply for Washer • Waste Standpipe for Washer
Other components tested • Door Bell
Observations
Gas range unit • R epair: The back right burner on the gas range is inoperative.
Photos
Dishwasher unit • No significant defects observed
Waste disposer unit • No significant defects observed
Refrigerator unit • Refrigerator appears to be in serviceable condition
Clothes dryer unit • Not tested • Appears servicable
Clothes washer unit • Not tested • Appears serviceable
Cooktop exhaust unit • No significant defects observed
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
**** Pine St, North Bend, OR 97459 Page 27
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes
Appliance
Observations cont.
Door bell system • No significant defects observed
Limitations
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection. • Please refer to ASHI standards of practice for further exclusion the limitations of inspection
Comments
Positive attributes All appliances that were tested responded satisfactorily.
General comments Only minor improvements to the appliances are needed.
This confidential report is prepared exclusively for Jerry and Shirlee M.©2018 Hutchs Custom Homes