Holophane Emergency Panelite Series Brochure 4-73

download Holophane Emergency Panelite Series Brochure 4-73

of 6

Transcript of Holophane Emergency Panelite Series Brochure 4-73

  • 7/28/2019 Holophane Emergency Panelite Series Brochure 4-73

    1/6

    rr-tl96lPo_)9lll tsRooB6o

    Holophane Panelitdf luorescent luminaires foremergency, security,and general use.

    j

  • 7/28/2019 Holophane Emergency Panelite Series Brochure 4-73

    2/6

    Panelite controls Iightprecisely- so importantrn emergencres.

    Widespread light distribution from eitherhorizontally or vertically mounted luminaires blanketslarge spaces.Precisely controlled illumination on ceiling andwalls from vertically mounted PANELITE defines roomoutlines, avoiding oppressive cavern effect whichcould cause panic. Allows people to maintain

    orientation as they head for exit. White rvrap-atoundunit provides even greater ceiling or wallillumination for improved depth pelception.Light distdbution is engineered to avoid glare,control luminaire brightness, and eliminate the brightbeam spoilight effect that momentarily blinds rvhenviewed directly (found in most other emergencylighting systems).Double-faced PANELITE takes fullest advantageof generated lamp lumens, especially useful in largeareas.

    Panelite ISesthetically pleasing.

    Compact, recessed luminaires are neat andunobtrusive, a far cry from bulky shelf-mountedboxes.

    Low silhouette and slim modern lines of surfacePANELITE complement interior - even at low ceiiingheights.Clean, simple trim that frames C0NTRoLENS@ orwrap-around presents esthetically pleasingappearance, even lvhen unit is not lighted.This family of genetal, emergency and securityluminaires comprises a complete lighting system . . ,all fixtures matching .

    Practically invisibleuntil needed.

  • 7/28/2019 Holophane Emergency Panelite Series Brochure 4-73

    3/6

    Panelite issimple to install.Mounts anyrvhere you want it, in any position, toprovide light where it is most needed.Less wiring is required since substantially fewer

    un iis are naeded lo iJluminale any gi\ en space.As simple to install as any standard, genetal-useluminaire.No danger from acid. Sealed batteries require noadditional liquid are as simple to handle asflashlight batteries.Additional batteries, lvhich extend emergencyoperating period, can be snapped into batterychamber.Five different interchangeable trims forrecessed PANELITE permit installation in a variety ofspecialized areas.Vandal-resistant units with tempered glassprotective cover or integrally cast guard are ideal forsecurity areas.Available also for direct concrete installation.Plaster fr.ame speeds economical installation, indoorsand outdoors.Fluorescent lamps are included with eachPANELITE luminaire.

    Adjustable bracketstit walls or csilings.

    Panelite requiresvirtually nomaintenance.

    Dependable, unique solid-state circuit. Nomovingpads, nothing to go lvrong, no mechanicalrelay to hang up.Optimum lamp performance. Solid-state switch andcircuit deliver full rated voltage to the lamp.Ratteries are sealed and maintenance-free. with

    an expected life of 8 years. Completely automaticcharging system requires no setting or adjustment,Patented battery charger restores battedesquickly, at rate of 4 hor"rrs of charge for each hour ofuse. Charger prolongs battery life,Unobtrusive blinking indicator lamp allows simplevisual inspection of PANELITE battery charging.Code-requil.ed test switch is readily accessible.Bug-tight construction eliminates need for cleaningof fixture.

    Test switch checks lamps.indicator light blinks to show batteriesare ready for a power emergency.

  • 7/28/2019 Holophane Emergency Panelite Series Brochure 4-73

    4/6

    EEFumnmat[om daita.

    lsolux chartIsolux cha|t shorving initial horizontalfootcandles on the floor from a recessed

    PANELTTE mounted in rvall3 feet above floorline. To convert isohrx chart values forluminaire mounting heights above 3 feet, usethe follorving multiplying factors :Height (ln feet) Factor4 .565 .366 .257 .laI .14

    / a--,,,.,,1 ) ,'iilll'--.. ii

    \ ,\ii..-23

    =1Pb

    i1

    Coeff icients of utilizationZonal Cavity MethodNo. M-51C with Wrap-Around No. M-42C-A with Conlrolens

    n coiiic.islM irc Ar

    0%500/" 300/" 100k 50./" 306/" 106/" 500/" 300/" 100/" 506/" 30./" 10./" o./"1 .48 .46 .44 .45 .4s .42 .37 't .44 .43 .42 .42 .41 .40 .372 .42 .39 .36 .s9 .36 .34 .31 2 .41 .3S .37 .38 .37 .36 .333 .37 .33 .30 .34 .31 .29 .26 3 .37 .35 .33 .36 .34 .32 .30n 4 .33 .28 .25 .30 .27 .24 .22 n 4 .34 .31 .25 .33 .30 .29 .21o 5 .25 .24 .21 .27 .23 .21 .19 (.) 5 .31 .28 .26 .30 .24 .26 .25- 6 .26 .21 .rB .24 .20 .18 ,i6 t 6 .2g .26 .24 .2a .2s .23 .zz7 .23 .19 .16 .22 .18 .15 .14 7 .26 .23 .21 .25 .23 .21 .208 .21 .17 .14 .19 .16 .13 .12 A .24 .21 .19 .23 .21 .19 .189 .19 .14 .12 .17 .14 .11 .10 L22 .19 .17 .21 .19 .17 .1610 .17 .13 .10 .16 .12 .10 .09 10 .19 .16 .14 .19 .16 .14 .13

  • 7/28/2019 Holophane Emergency Panelite Series Brochure 4-73

    5/6

    Panelite offers a choice of stylesfora broad range of applications.

    PANELITE is available for general, emergency, orsecurity lighting, and with a choice of inter-changeable trim and housing styles. Combinespleasing appearance with efficient control of light.Choose an emergency PANELITE for battery-powered light that comes on instantly if no1.rnal powerfails, and remains on at rated output for morethan 60 minutes. (Optionally to more than 2 hours.)Choose a g eneral'ilLunLination P LNELI\E whelj.you need a compact fluorescent fixture for normal,non-emergency lighting.Choose a securitv P,lrqnurp for a combination of

    general and emerg'ency lighting from the sameluminaire. Avoids the cluttered look and higher costof separate luminaires,

    Broad range ol Panelite applications:AuditoriumsBanksControl roomsElevatorsEquipment roomsExternal building

    lvallsFreezetsHospitalsT,obbiesllanufacturing

    M.rximum securityjailsIlental rvardsOlficesOutdoor canopiesStairsStoresTerminalsTheatersTunnelsWatchman stationsand many more

    Flat trim blendswiih ceiling.

    CAT NO. SUFFIX .AThe llal trim with acrylic prismaticCoNTFoLENS blends inlo thebacksround unobtrusively. Th jsluminairo provides uselul down lightwith a minimum of glare. Thestandard trim is steel, painled white.Many styles of acrylic lenses areavailable.While wrap-around providesadditional side light.

    Tempered glass cover loradded proteclion.

    CAT. NO SUFFiX BFor locations where grealer vandal-resisiance is requlred, a lemperedclear qlass cover is Orovlded in a caslaluminum lfame. Thjs qlass isvirtually impossible to break,protecling the CONTBOLENS withoutinterfering with its li!hlconlrol.

    Surlace-mounted unitsresist vandalism.

    Cast guard protectsagainsl breakage.

  • 7/28/2019 Holophane Emergency Panelite Series Brochure 4-73

    6/6

    IIDirnensions.

    F ai tr n Bith Co.tro.nslsuiilx A), recessed. Vandal resisianl ho!sin9(suttix B, C or -D). recessed.

    F rr, =l

    Flar trim w rh white acrylicwrap around (s!il x E). w lh orwithoul lelter n9. recessedwhile acrylc wrap around, doubleiace (cat. no. M.54C, M-55C) andsinqe-race (cai no. M-51C, M52C), wilh or wilho!i lellernq,

    11

    Specification and ordering data"

    SecurityLiohtindd;;- Fo, ac..d io, ,-r".ro. 'rsrd dr o-rsien./emerq.) M-43C Se riesb.ci 15 r 15

    a. Unils supplied wlth lamps;emergency and security units suppliedwilh iwo batter es. All un ls operate lrom 115 vo ts. ll 277 voltoperalion ls des red. add -277 sufilx to catalog number.b. Complete Cat. No. cons sts ol series no. pl!s sr.rif x leifer thaldesignates desired lrlm and light conlro. Example: Securlty lighi,recessed with wh le wrap around: N.4 ,13C E. Weight lisied for serles isfor one unit with f at trim and CoNTBoLENS. Add lional weights lorother irims are given al right.c. Specify lettering. li any, on y on unlis with white acryllc wrap-arounds.Slandard color s rediother co ors ava lable on reqLresl. Suggestedletterins: EXIT, 2nd FLOOR, STAIRS.d. See accessories io select appliceble wall bracket.e. Lamps are I qhted at all 1 mes to avoid cold-start problems whenf. Lisled by Underwrilers Laborator es, lnc. as Emergency LightingEquipmenl.g. Lisred by Underwrilers' Laboratories, lnc.Aceessonles.

    Contact your local Holophane sales engineer for app ication assistance,computer-alded design and cost studies, and samp e unlts for trial installatlon.

    lnterchanqeable Trim & Liqhl Control Suflix Added WeiqhtFlat irim with CONTFOLENSCast aluminum wiih CONTRoLENS andCasi aluminum w th CONTRoLENS andguardCast alum num wiih CONTRoLENS andlernpered g ass and guardFlat lrlm wlth whiie ac.ylic wrap-aro!nd

    -Bc

    .D-E

    4 tb.2lb.5lb.1tb.

    Bouqhing Box FramedLensth Width OpeningGeneral Recessed for lnterior insia lalionsLighling R"..s"ed fo, dite.ct cor,crere insta lalion]."i,,.-J "-"p, S ,"d- -^-oLr "d lpd.\ d-r..ld^ oer-;; ;;i;:;;, i"".i,:'; c{,. """";:;j y; : "..

    M-41C Seriesb,c. q l4 t!M 44C Seriesb c.s 141,h 141h 141/2 x t41/2 67k141/e .t41/z x 141/2 67/s l5 x 15 18b15 x 15 24b15 x 15 27

    Becessed ior nle rior installationsR""essed l"r dtre"t "".,"r.t" i."1"il"1b.Mornlc.l on wall brackei an.l cor.l-connected {tor portab e use also), single-Mounted on wall brackei, permanenlconnect on to electrical oullet singe-f/oLrnted on wall bracket or cei ns,cord-connecled, double face whlte acrylicMounted on wa I bracket or ceiling,permanent conneclion io electrical oullet,double-fare wh le rc,Vlic wrao rroundI ow ta- o-trIIp. sL td, a.nroJ'rrod. 1oo./

    M 42C Seriesb c i 141isM-45C Seriesb.c J 14r/s[.4,.17C, tlt-47C-Dil\.4-51Cc d(aux lary lig ht ng)M 52C c.d.fM 54Cc.d(auxlliary lq ht nq)

    15 x 1515 x i515 x 15

    123/a x 123/a123/a x 123/a123/a x 123/a123/a x 123/a

    15 x 15

    t\,4-51-WM-52 WM-68[,1,41 MF-90

    Wall brackel for M-51C. M 54CWall bracket lor 1,4 52C, M 55CAdditional batlery set (2 balteries)Plaster frame lor recessed PANELITE, 14yr" sq. opening required[4ounling lrame lor recessed PANELITE for T-bar ce]ling 24" o.c.2 exira baiieries for minimum of 90 m nules of egally required lighting

    h"f p,f o p h a n g riJBB l',r i 3," r,?:: i,rr i "yii %'i i, B,i,r Br o o,Pr nred ;. u s A i92