SIMATIC HMI Basic Panels Erweiterungen mit WinCC flexible 2008 SP2Produktinformation

GltigkeitsbereichDie vorliegende Produktinformation gilt fr folgende Bediengerte: KTP400 BASIC MONO PN Bestellnummer 6AV6647-0AA11-3AX0 KTP600 BASIC MONO PN KTP600 BASIC COLOR DP KTP600 BASIC COLOR PN KTP1000 BASIC COLOR DP KTP1000 BASIC COLOR PN TP1500 BASIC COLOR PN

Bestellnummer 6AV6647-0AB11-3AX0 Bestellnummer 6AV6647-0AC11-3AX0 Bestellnummer 6AV6647-0AD11-3AX0 Bestellnummer 6AV6647-0AE11-3AX0 Bestellnummer 6AV6647-0AF11-3AX0 Bestellnummer 6AV6647-0AG11-3AX0

Diese Produkinformation beschreibt die Funktionserweiterungen der Bediengerte in Verbindung mit der Software WinCC flexible 2008 SP2. Diese Produktinformation enthlt wichtige Hinweise. Diese Hinweise ergnzen die Betriebsanleitung fr das Bediengert und sind den Aussagen in der Betriebsanleitung, in den Release Notes und in der Online-Hilfe in der Verbindlichkeit bergeordnet.

Funktionsumfang mit WinCC flexibleDie folgenden Tabellen zeigen die Objekte, die in einem Projekt fr ein Basic Panel eingebunden sein knnen. Meldungen Objekt Meldepuffer, remanent Spezifizierung Kapazitt des Meldepuffers Gleichzeitig anstehende Meldeereignisse Basic Panels 256 Meldungen Max. 64

Meldung ansehen Meldepuffer lschenVariablen, Werte und Listen Objekt Spezifizierung KTP400 Basic

Ja Ja

KTP600 Basic, KTP1000 Basic, TP1500 Basic 500

Variablen Neue Systemfunktionen

Anzahl

250

In Ergnzung zu den bereits verfgbaren Systemfunktionen untersttzt WinCC flexible 2008 SP2 fr die Basic Panels folgende Systemfunktionen: Systemfunktion/Syntax SetzeBitInVariable (Variable, Bit) RuecksetzeBitInVariable (Variable, Bit) InvertiereBitInVariable (Variable, Bit) Verwendung Setzt ein Bit in der angegebenen Variable auf 1 (TRUE) Setzt ein Bit in der angegebenen Variable auf 0 (FALSE) Invertiert ein Bit in der angegebenen Variable

Weitere Informationen finden Sie unter "Systemfunktionen" in der Online-Hilfe von WinCC flexible. Siemens 2010 A5E02766876-01, 04/2010

1

Kompatible SteuerungenMit WinCC flexible 2008 SP2 wurde die Kompatibilitt der Basic Panels zu Steuerungen erweitert. Basic Panels DP Sie knnen Basic Panels DP ber die RS 422/RS 485-Schnittstelle an folgende Steuerungen anschlieen: Hersteller Kommunikationstreiber, Protokoll, Zusatzmodule SIMATIC S7 200 SIMATIC S7 300/400 Allen Bradley Allen Bradley DF1 ber KF2-Modul an DH+ LAN ber KF3- Modul an DH485 LAN Mitsubishi Modicon (Schneider Automation) Omron Mitsubishi FX Modicon Modbus Modbus RTU-Protokoll mit Modbus Plus Bridge Omron Hostlink / Multilink RS 232 Punkt-zu-Punkt RS 422 Mehrpunkt-Ankopplung 1 1) 4 CP1L-x, CP1H-x, CJ1M CPU11 1 1) 41)

Steuerungen (Typen) Maximale Anzahl Verbindungen von HMI zu Steuerungen 4 2) 4 1 1) 4 4 11)

Siemens

SIMATIC S7-200 SIMATIC S7-300/400 PLC5 PLC5, SLC5/04 SLC500, SLC5/01, SLC5/02, SLC5/03, SLC5/04, SLC5/05, MicroLogix MELSEC FX1S, FX1N, FX2N Serien Modicon 984, TSX Compact, TSX Quantum

1) 2)

Nur mit Konverter RS 422-RS 232 ber PPI maximal eine Verbindung

Basic Panels PN Sie knnen Basic Panels PN ber die PROFINET/LAN-Schnittstelle an folgende Steuerungen anschlieen: Hersteller Kommunikationstreiber, Protokoll, Zusatzmodule SIMATIC S7 - PROFINET Modicon MODBUS TCP/IP Modbus TCP/IP mit Ethernet TCP/IP Modbus Plus Bridge 4 4 Serien Quantum, Momentum, Premium und Micro Serien Modicon 984, TSX Compact Steuerungen (Typen) Maximale Anzahl Verbindungen von HMI zu Steuerungen 4 SIMATIC S7-200/300/400/1200

Siemens Modicon (Schneider Automation)

Siemens AG Industry Sector Postfach 48 48 90026 NRNBERG Erweiterungen mit WinCC flexible 2008 SP2 A5E02766876-01, 04/2010 2 Erweiterungen mit WinCC flexible 2008 SP2 A5E02766876-01, 04/2010

SIMATIC HMI Basic Panels Expansions with WinCC flexible 2008 SP2Product Information

Area of applicationThe product information applies to the following HMI devices: KTP400 BASIC MONO PN Order number 6AV6647-0AA11-3AX0 KTP600 BASIC MONO PN KTP600 BASIC COLOR DP KTP600 BASIC COLOR PN KTP1000 BASIC COLOR DP KTP1000 BASIC COLOR PN TP1500 BASIC COLOR PN

Order number 6AV6647-0AB11-3AX0 Order number 6AV6647-0AC11-3AX0 Order number 6AV6647-0AD11-3AX0 Order number 6AV6647-0AE11-3AX0 Order number 6AV6647-0AF11-3AX0 Order number 6AV6647-0AG11-3AX0

This product information describes the function expansions of the HMI devices in conjunction with the WinCC flexible 2008 SP2 software. This product information contains important information. These notes supplement the operating instructions for the HMI device and take precedence over statements in the operating instructions, the release notes, and in the online help.

Functional Scope with WinCC flexibleThe following tables show the objects that can be integrated in a project for a Basic Panel. Alarms Object Alarm buffer, retentive Specification Alarm buffer capacity Simultaneously queued alarm events Basic Panels 256 alarms Max. 64

View alarm Delete alarm bufferTags, values and lists Object Specification KTP400 Basic

Yes Yes

KTP600 Basic, KTP1000 Basic, TP1500 Basic 500

Tags New system functions

Quantity

250

In addition to the system functions already available, WinCC flexible 2008 SP2 supports the following system functions for the Basic Panels: System function/syntax SetBitInTag (Tag, Bit) ReSetBitInTag (Tag, Bit) InvertBitInTag (Tag, Bit) Application Sets a bit in the specified tag to 1 (TRUE). Sets a bit in the specified tag to 0 (FALSE). Inverts a bit in the specified tag.

For more information, refer to "System functions" in the Online Help of WinCC flexible. Siemens 2010 A5E02766876-01, 04/2010

3

Compatible controllersWith WinCC flexible 2008 SP2, the compatibility of the Basic Panels to PLCs has been expanded. Basic Panels DP You can connect Basic Panels DP via the RS 422/RS 485 interface to the following PLCs: Manufacturer Communication driver, Protocol, additional modules SIMATIC S7 200 SIMATIC S7 300/400 Allen Bradley Allen Bradley DF1 via KF2 module to DH+ LAN via KF3 module to DH485 LAN Mitsubishi Modicon (Schneider Automation) Omron Mitsubishi FX Modicon Modbus Modbus RTU protocol with Modbus Plus Bridge Omron Hostlink / Multilink RS 232 point-to-point RS 422 multipoint connection 1 1) 4 CP1L-x, CP1H-x, CJ1M CPU11 1 1) 41)

Maximum number of connections from HMI to PLCs 4 2) 4 1 1) 4 4 11)

PLCs (types)

Siemens

SIMATIC S7-200 SIMATIC S7-300/400 PLC5 PLC5, SLC5/04 SLC500, SLC5/01, SLC5/02, SLC5/03, SLC5/04, SLC5/05, MicroLogix MELSEC FX1S, FX1N, FX2N Modicon 984, TSX Compact and TSX Quantum series

1) 2)

Only with RS 422-RS 232 converter Maximum one connection via PPI

Basic Panels PN You can interconnect Basic Panels PN via the PROFINET/LAN interface with the following PLCs: Manufacturer Communication driver, Protocol, additional modules SIMATIC S7 - PROFINET Modicon MODBUS TCP/IP Modbus TCP/IP with Ethernet TCP/IP Modbus Plus Bridge 4 4 Quantum, Momentum, Premium, and Micro series Modicon 984, TSX Compact series Maximum number of connections from HMI to PLCs 4 PLCs (types)

Siemens Modicon (Schneider Automation)

SIMATIC S7-200/300/400/1200

Siemens AG Industry Sector Postfach 48 48 90026 NRNBERG Expansions with WinCC flexible 2008 SP2 A5E02766876-01, 04/2010 4 Expansions with WinCC flexible 2008 SP2 A5E02766876-01, 04/2010

SIMATIC HMI Basic Panels Extensions avec WinCC flexible 2008 SP2Information produit

Domaine de validitCette information produit est valable pour les pupitres oprateur suivants : KTP400 BASIC MONO PN Rfrence 6AV6647-0AA11-3AX0 KTP600 BASIC MONO PN KTP600 BASIC COLOR DP KTP600 BASIC COLOR PN KTP1000 BASIC COLOR DP KTP1000 BASIC COLOR PN TP1500 BASIC COLOR PN

Rfrence 6AV6647-0AB11-3AX0 Rfrence 6AV6647-0AC11-3AX0 Rfrence 6AV6647-0AD11-3AX0 Rfrence 6AV6647-0AE11-3AX0 Rfrence 6AV6647-0AF11-3AX0 Rfrence 6AV6647-0AG11-3AX0

Cette information produit dcrit les extensions fonctionnelles des pupitres oprateur en liaison avec le logiciel WinCC flexible 2008 SP2. Cette information produit contient des indications importantes. Ces informations compltent les instructions de service du pupitre oprateur et, en cas de conflit avec les indications contenues dans les instructions de service, les Release Notes et l'aide en ligne, c'est elles que vous devez vous reporter.

Etendue des fonctions avec WinCC flexibleLes tableaux suivants prsentent les objets pouvant tre intgrs un projet destin un Basic Panel. Alarmes Objet Tampon d'alarmes rmanent Spcification Capacit du tampon d'alarmes Evnements d'alarme simultanment en attente Basic Panels 256 alarmes max. 64

Consulter l'alarme Effacement du tampon d'alarmesVariables, valeurs et listes Objet Spcification KTP400 Basic

Oui Oui

KTP600 Basic, KTP1000 Basic, TP1500 Basic 500

Variables Nouvelles fonctions systme

Nombre

250

WinCC flexible 2008 SP2 prend en charge les fonctions systme suivantes pour les Basic Panels en complment des fonctions systme dj disponibles : Fonction systme / syntaxe PositionnerBitDansVariable (variable, bit) RAZBitDansVariable (variable, bit) InverserBitDansVariable (variable, bit) Utilisation Cette fonction positionne un bit dans la variable indique sur 1 (TRUE). Cette fonction positionne un bit dans la variable indique sur 0 (FALSE). Cette fonction inverse un bit dans la variable indique.

Pour plus d'informations, rfrez-vous "Fonctions systme" dans l'aide en ligne de WinCC flexible. Siemens 2010 A5E02766876-01, 04/2010

5

Automates compatiblesLa compatibilit des Basic Panels avec les automates a t tendue dans WinCC flexible 2008 SP2. Basic Panels DP Vous pouvez rac