HMC+and+V7+System+p VUG

83
i want stress free IT. i want control. i want IBM. IBM Power Systems IBM System p Virtual User Group November 20, 2008 Allyn Walsh [email protected] HMC V7.3 POWER6 and Power Systems ® © IBM Corporation 2008

Transcript of HMC+and+V7+System+p VUG

Page 1: HMC+and+V7+System+p VUG

i want stress free IT.i want control.

i want IBM.

IBM Power Systems

IBM System p Virtual User Group November 20, 2008

Allyn [email protected]

HMC V7.3 POWER6 and Power Systems

®

© IBM Corporation 2008

Page 2: HMC+and+V7+System+p VUG

2 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

AgendaHardware Management Console background

– What is an HMC and when is it required– HMC Hardware models– POWER firmware architecture

HMC upgrade and update managementHMC Backup and recovery strategiesConnection options

– Single server, multiple server, open network access

Remote management - Features and functions– GUI server management– WebSM or browser based access with HMC V7– SSH (secure shell)

Added features with V7.3.1 - V7.3.3– New Call home wizard– User data Replication– IPv6, Authentication options (local, Kerberos or LDAP)– Multiple Shared Processor pools– Shared Dedicated Processor– Hot Node add / Repair

Page 3: HMC+and+V7+System+p VUG

3 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

A user interface for POWER5 and POWER6 hardware management

– Virtualization management – Intel based platform - GUI console application– Third party applications locked out– Regular refreshes on the hardware technology

POWER6 minimum HMC firmware level V7.310– V7.3 is compatible with POWER5 servers

– Support statement says level SF240_299 or later on POWER5 servers

Remote management of HMC functions– WebSM client – remote GUI to HMC for V6.1.3 and

all earlier versions– Standard browser for remote GUI access to HMC

V7.310 and above– Secure shell (SSH) access to CLI command line

interface

HMC Supports:– Max of 48 Servers, up to 254 partitions. – Max of 2 HMC's per server.

When is it required on POWER Systems• HMC is Required:

• POWER6 570 (9406-MMA / 9117-MMA)• HMC V7.330 for unified 9117-MMA

• POWER6 595 (9119-FHA)• HMC V7.330 minimum level to support FHA

• Required on POWER5 or POWER6 systems when:• Systems with LPARs - Logical Partitions

• Except 8203-E4A and 8204-E8A using PowerVM express edition

• Systems requiring full CuOD (Capacity upgrade On Demand)

• ASMI has subset of CuOD functions • Systems with redundant flexible service processors

(FSP)• POWER5 570 with optional redundant FSP• POWER5 590 & 595

• Systems with Bulk Power Assemblies (595 only)

• CFM - Concurrent Firmware Maintenance enabled only for HMC managed systems

NOTE:If none of the above conditions are true (single OS image), HMC is optional

Page 4: HMC+and+V7+System+p VUG

4 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Hardware Management Console - Model refreshes

7310-CR27310-C03

Rack mounted display and keyboardOrdered separately

General Availability• New orders for POWER5 will continue to default to 7310-CR4/C06 models • HMC function is based on HMC Version/Release installed (not the HMC model)• 7310-Cxx models can be upgraded to V7.3 (minimum HMC level required for POWER 6

7310-CR37310-C04

(desktop)(rack)

7310-C057310-CR4

7042-CR47310-C06For POWER6 servers, new HMC orders will default to

models 7042-Cxx & ship preloaded with V7.3xx

7042-C06

Page 5: HMC+and+V7+System+p VUG

5 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

The 3 Pieces of i5 Maintenancei5

Man

aged

Syst

em

Server Firmware• Power Hypervisor• Flexible Service

Processor• Power Code (BPC)

HMC• Updates and Upgrades

Partition Maintenance• i5/OS & LIC, AIX, Linux

Page 6: HMC+and+V7+System+p VUG

6 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Check HMC code level and eFixes installed

Starting with V4R5, this interface was enhanced to automatically show eFix information along with Version Release, even from a WebSM session

To view Version/Release, Expand License Internal Code Maintenance and select HMC Code Update. Prior to V4R5, the only way to see eFixes was to select ‘Help’ on the HMC Code Update panel on the HMC. eFix information was not available from a WebSM session

Notice that HMC code uses a Version/Release format and maintenance is identified by MHxxxxx ptf IDs. MHxxxxx PTF’s are also used for i5/OS server firmware maintenance.

Page 7: HMC+and+V7+System+p VUG

7 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Multiple ways to check HMC code level on V7.310Just hover the cursor over the HMC Version on the Welcome screen or select Updates.

Select the Updates tab

Page 8: HMC+and+V7+System+p VUG

8 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Upgrading and Updating the HMCTerms

– Upgrading the HMC– Changing the HMC to a new

Version or a new release level– Recovery Media = Upgrade

– Updating the HMC– Updating the HMC within the

current release– Install Corrective Service

– i.e. Applying a V5R2.0 required efix

– Bring the HMC to a new point release by installing an update PTF

Upgrading or Updating the HMC is a Concurrent Process (performed independent of the servers that it manages)

Obtain the HMC code maintenance – Traditional

– Order the fix as a PTF and is received on media

– Internet– Fix or Update file can be downloaded

directly to the HMC– Zip file can be downloaded

– Zip file can be used with the updhmc command or copied from a FTP server that’s behind the firewall

– ISO file can be downloaded and burned– Image of the media, requires an

authoring program

– FTP– Files can be downloaded to any FTP

server that HMC can access

Page 9: HMC+and+V7+System+p VUG

9 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Upgrading the HMC to a New ReleaseVer/Rel/point_level of HMC i.e. (V6.1.3 = version 6, release 1, point level 3)HMC version upgrade required Recovery media.

– Starting with version 5, release upgrades require recovery media– V4.x to V4.x (Could be done using Recovery media or Update media)– V4.5 to V5.1 – Recovery media required– V4.5 (with special steps) to V6.1 – Recovery media required– V5.2 to V6.1.x – Recovery media required– V6.1.2 to V7.310 – Recovery media required– V7.3.3 must use recovery media AND come from V7.3.1 or V7.3.2

Recovery Media is an Upgrade - (boot the HMC from media)– One step short of a scratch install– Upgrade option preserves saved upgrade data on hard drive and/or media– Overwrites all other HMC code and configuration files

Update the HMC release using Corrective Service– Uses an update PTF instead of Recovery Media – Overwrites existing files, adds those needed, does not change the recovery point– Can increase time need for Backup Critical Console Data

Starting with V5R1can upgrade

and install the HMCfrom a server on

the network

Page 10: HMC+and+V7+System+p VUG

10 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC Home page has a new look to ithttps://www14.software.ibm.com/webapp/set2/sas/f/hmc/home.html

Page 11: HMC+and+V7+System+p VUG

11 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC Documentation websitehttps://www14.software.ibm.com/webapp/set2/sas/f/hmc/resources.html

Why do you think we still give you the option to get back-level HMC code?

Page 12: HMC+and+V7+System+p VUG

12 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

POWER code matrixhttps://www14.software.ibm.com/webapp/set2/sas/f/power5cm/home.html

Page 13: HMC+and+V7+System+p VUG

13 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Sign up for notification on critical topicshttps://www.ibm.com/systems/support/myview/subscription/css.wss/folders?methodName=listMyFolders

Example Notification

Page 14: HMC+and+V7+System+p VUG

14 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

https://www14.software.ibm.com/webapp/set2/sas/f/hmc/home.htmlHMC Firmware – Upgrade & Install Instructions

BOOK MARK this page

Page 15: HMC+and+V7+System+p VUG

15 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Select downloads for details

Page 16: HMC+and+V7+System+p VUG

16 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC V7 R3.3.0 (Released on 5/7/08) upgrade notes

Prerequisite task required to preserve existing HMC configuration

Save Upgrade Data

Upgrading from HMC V6.1.2 or higher HMC V6 is a two-step process. You must first upgrade via Recovery media to HMC V7 R3.1.0 or HMC V7 R3.2.0 before you can upgrade to HMC V7 R3.3.0

Required for upgrade from lower level of HMC V7.

Recovery MediaUpgrade notes

Minimum levels required for POWER5 systems managed by HMC 7.3.3.0

SF240_299 and higher

Minimum levels required for POWER6 systems managed by HMC 7.3.3.0. See Power code matrix for supported and recommended F/W and HMC code combinations for different POWER6 systems.

EM310_060 and higher EM320_040 and higher EL320_040 and higher

System Firmware

• HMC machine type 7310 with V6 R1.2 or higher may upgrade to HMC V7 R3.1.0 or V7R3.2.0. • Order MES (Miscellaneous Equipment Specification) 0962 through IBM Sales Representative

or Business Partner. • HMC code V7.3 Recovery media may also be downloaded, but MES 0962 must still be ordered to complete the conversion from V6 to V7.

Page 17: HMC+and+V7+System+p VUG

17 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Select Recovery media for upgrades to reset recovery pointSelect Update for routine maintenance

Page 18: HMC+and+V7+System+p VUG

18 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Optional Network install or Upgradehttps://www14.software.ibm.com/webapp/set2/sas/f/hmc/power6/install/v7.Recover_Network.html#PXE

This is an example using Network images

Page 19: HMC+and+V7+System+p VUG

19 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Upgrade procedure using DVD media

Page 20: HMC+and+V7+System+p VUG

20 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Back Up Critical Console Data

• What gets Backed Up• Where can the Back Up be Saved• Performing a Back Up• Restoring Critical Data

Page 21: HMC+and+V7+System+p VUG

21 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

What gets Backed Up

Those files with a timestamp later than the trigger file are candidates for backup.

The data that is backed up can be divided into 2 categories

– HMC specific– User Profiles– Roles and Tasks– Network Configuration– Applied Corrective Service Updates

– HMC operating system– Service packs, eFixes– OS Security update– Infocenter

In general, Backup Critical Console Data archives:

– Code Changes to the HMC Application(s) since the last install or recovery upgrade

– HMC unique configuration changes since the last install or recovery upgrade

– User Profiles– Network Configuration– Service Data– Etc.

– Platform specific information since the last install

– Managed Systems– Partition Profiles – Etc.

– HMC operating system updates applied since the last install

Page 22: HMC+and+V7+System+p VUG

22 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Save Critical Console Data (Save CCD) vs. Save Upgrade data

CCD is not a ‘bootable’ save of the HMC– In a recovery scenario you need:

– The HMC Recovery CDs (or DVDs) that were used with the install or the last upgrade – PLUS the Save CCD data.

– Options to Save to: – DVD-RAM– FTP server– NFS server

Save Upgrade data is different from CCD– Use this option only before HMC Upgrade– Saves only user modified System configuration, User Profile & Security info,

Service information

Page 23: HMC+and+V7+System+p VUG

23 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC Backup options

Saving Critical Console data should be part of your normal system management process. A backup should be performed following any significant change. i.e. upgrades, updates, security changes – other user customizations, etc. It will save all changes to the HMC firmware and all users modifications.

To back up the HMC (Back-up Critical Console Data), you must be a member of one of the following roles:

• super administrator • operator • service representative To back up the HMC, do the following: 1. In the Navigation area, click the Licensed Internal Code

Maintenance icon. 2. In the Contents area, click the HMC Code Update icon. 3. Select Back up Critical Console Data. 4. Select an archive option. You can back up to DVD on the

HMC, back up to a remote system mounted to the HMC file system (such as NFS), or a remote site through FTP.

5. Follow the instructions on the panel to back up the data.

Page 24: HMC+and+V7+System+p VUG

24 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

V7.3 All HMC management functions from a single menu

Page 25: HMC+and+V7+System+p VUG

25 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Recovery mediaRequired for version upgrades / Suggested for release upgrades.

Benefit to install from Recovery CD'sBecomes the new the recovery point Reset the Save CCD data pointReduces the volume of data to be save by Save CCD

Upgrade release level using update.zip files. Increased the volume of data to be saved by 'Save Critical Consol Data‘ (save CCD).

Makes a copy of every object that has changed since the base install or last recovery media Example: system ships with V4R1.0 preloaded.

Update using Update.Zip files to move to V4R2.0 then V4R3.0 then V4R4.0Recovery point is still V4R1 Recovery CD’s plus the Critical Console Data after V4R4.0

Recommended: Upgrade procedure with Recovery media:Example: Upgrade from V4R1 to V4R4 the procedure would be:

1) optional – Save CCD2) Save Upgrade Data3) Boot from the V4R4 Recovery CD's MH002214) Restore the saved Upgrade Data (will occur automatically as part of the upgrade)5) Apply any V4 R4.0 Required Maintenance efix (MH00219 in this example)6) Save Critical Console Data7) Recovery point is now V4R4 CD’s, plus CCD taken after maintenance

Page 26: HMC+and+V7+System+p VUG

26 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Why CCD backup can take a while…Two methods of HMC software Release Upgrades

– Update via corrective service –‘Update.zip’ files

– Upgrade with new release Recovery CD’s (V5R1 and later uses DVD media) For example upgrading from V5R1 to V5R2 or directly to V5R2.1

Size matters – could be +1GBSave performance is improved

HMC Recovery DVD set V5R1 HMC Correct Service Update to V5R2.1 User data

HMC Recovery DVD set 5.2.1 User data

Data saved in backup A

B Data saved in backup

Critical Console Data Backup

Page 27: HMC+and+V7+System+p VUG

27 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC Release Update Matrix

EM320 or EL320MH01059

NAMH01060MH01084

12/200703/2008

V7.320V7.320 SP1

(POWER6)EM310

MH00998NA

NAMH01042

06/200709/2007

V7.310V7.310 SP1

MH00563MH005945/19/2006V5R2.1

MH00752NA

MH00919NA

NAMH00839MH00915MH01012

08/200611/200602/200709/2007

V6R1V6R1.1V6R1.2V6R1.3

SF240MH00521MH005642/24/2006V5R2.0

EM320 or EL320 @ sp 076

And EH330MH01097

NANA

MH0110504/200806/2008

V7.330V7.330 SP1

NAMH005934/14/2006V5R1.2

SF235MH00407NA12/7/2005V5R1.0 -

SF230MH00267MH002686/6/2005V4R5.0

SF225MH00221MH002234/8/2005V4R4.0

SF222MH00191MH0015311/19/2004V4R3.1 -

NAMH001389/24/2004V4R2.1

SF220MH00106MH001078/30/2004V4R2.0

NAMH000978/3/2004V4R1.3

SF210NANANAV4R1.0 -

FirmwareRecovery MediaUpgrade PTFDate AvailableHMC

Page 28: HMC+and+V7+System+p VUG

28 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

http://www14.software.ibm.com/webapp/set2/firmware/gjsn

Home page for Power Systems Firmware

Page 29: HMC+and+V7+System+p VUG

29 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

POWER6 Server Firmware: Update Policy Set to HMC http://www-912.ibm.com/s_dir/slkbase.nsf/ibmscdirect/E58D7BBF0EAC9A2786256EAD005F54D8

Page 30: HMC+and+V7+System+p VUG

30 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Single HMC to one Power System – valid on POWER5 5+ and POWER6 systems with a single FSP

Direct Ethernet cable from HMC Eth0 to HMC0 or HMC1 port on the FSP (Flexible Service processor)Cable can be a standard Ethernet cable or crossover cable

Configure DHCP services on the HMC or assign ‘static’ IP addresses:HMC and Service processor

FSP default configuration is DHCP client, however, each port has a predefined default IP addresses POWER 5 default FSP addresses192.168.2.147 for HMC0 port 192.168.3.147 for HMC1 portPOWER6 default FSP addressesFSP-A: 168.254.2.147 for HMC0 port 168.254.3.147 for HMC1 portFSP-B168.254.2.146 for HMC0 port 168.254.3.146 for HMC1 port

FSP

HMC-0

HMC-1

HMC to FSP is always SL-Encrypted

HMC to a single server, no external switch is required

HMC Network Connection options

Page 31: HMC+and+V7+System+p VUG

31 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

POWER5 570 with “optional” redundant FSP and single HMCNOTE: POWER6 570 – 5-way or larger, automatically has redundant FSP

The option for dual service processors on the POWER5 570 was introduced in October, 2005. Dual service processor support is available only on the 5/8 way or larger 570 systems and requires anHMC to manage this. The HMC and server firmware must be on minimum HMC code level and server firmware level, and HMC must be correctly networked to support dynamic FSP failover.

The HMC must attach to both FSPs on the 570 using an Ethernet switch or hub. Typically this would be HMC0 ports. The HMC can provide DHCP services for IP address assignment or static IP addressing may be used

Attach a standard Ethernet cable (or cross-over cable) from HMC1 port on the first service processor directly to HMC1 port on the second service processor. This is required for failure detection and dynamic failover.

POWER6 570 two enclosure (5/8 way or larger) comes standard with dual FSPs and the HMC1 to HMC1 connecting cable is no longer needed.

Service Processor

HMC1 HMC0

Service Processor

HMC0 HMC1

Ethernet cableSwitch

P5 570-A

Page 32: HMC+and+V7+System+p VUG

32 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Redundant HMC configuration – using a central control centerIn this example, HMC1 will manage 570-A, attaching to HMC0-Port on each of the two Service Processors

HMC2 will manage 570-B, attaching to HMC0-Port on each of the two Service Processors

HMC3 will manage 570-A and i570-B attaching to HMC1-Port

on each of the four Service Processors

Switch

FSP HMC0

HMC1

FSP HMC0

HMC1

Switch

FSP HMC0

HMC1

FSP HMC0

HMC1HMC3

HMC1

HMC2

DHCP-SUBNET-1.1.1.1

DHCP-SUBNET-2.2.2.2

DHCP-SUBNET-3.3.3.3

For a WAN connection use Static IP addressing

570-A

570-B

Switch

Intranet Network

Page 33: HMC+and+V7+System+p VUG

33 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC1 will manage the local 570-A in LA, attaching to HMC1-Port on each of the two Service Processors using DHCP. It will provide redundant management of 570B in NYC using static/assigned IP addresses within the the corporate intranet

HMC2 will manage the local 570-B in NYC attaching to HMC1-Port on each of the two Service Processors using DHCP. It will provide redundant management of 570A in NYC using static/assigned IP addresses within the corporate intranet

Switch

FSP HMC1

HMC2

FSP HMC1

HMC2

Switch

FSP HMC1

HMC2

FSP HMC1

HMC2

HMC1

HMC2

Private – HMC Managed DHCP-SUBNET-192.168.x.x

Private – HMC Managed DHCP-SUBNET-172.17.x.x

LA Center

NYC Center

Open Network - Static IP Address – i.e - 12.34.56.xx

Static IP Address – i.e - 12.34.56.xx

Static IP Address – i.e - 12.34.55.xx

Open Network - Static IP Address – i.e - 12.34.55.xx

Static IP Address – i.e - 12.34.56.xx

570-A

570-A

Seattle

Miami

Corporate

network

WebSM V6 or earlier HMC remote management

Browser V7 HMC remote

management

Static IP Address – i.e - 12.34.55.xx

Page 34: HMC+and+V7+System+p VUG

34 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC (V6.1.3 or earlier) Setup Wizard

Page 35: HMC+and+V7+System+p VUG

35 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC (V7.3xx) Welcome page – Browser based interface

HMC V7.xxx provides a Browser based user interface. Very user friendly, multiple paths to various features and functions, i.e.:Status indicators

Easy (float over) access to HMC code level details

Page 36: HMC+and+V7+System+p VUG

36 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Start with the POWER Systems Hardware Info centerhttp://publib.boulder.ibm.com/infocenter/systems/scope/hw/index.jsp?topic=/iphad/f7310cr4hmc.htm

Configuration Checklist

http://http://publib.boulder.ibm.com/infocenter/eserver/v1r3s/index.jsp?topic=/iphai/configchklst.htm

Page 37: HMC+and+V7+System+p VUG

37 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC Electronic Service Agent: Connections options

Prior to V7.3.3.0, the Call-Home setup was included in the Guided setup wizard. Now a separate wizard.

Page 38: HMC+and+V7+System+p VUG

38 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Electronic Service Agent: Connections options cont.

Page 39: HMC+and+V7+System+p VUG

39 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

LPAR Service and Support Configuration Options

Basic set up

http://publib.boulder.ibm.com/infocenter/systems/scope/aix/index.jsp?topic=/rzaji/service_agent.htm

Page 40: HMC+and+V7+System+p VUG

40 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC provides multiple User Interfaces and AccessLocal GUI (on HMC)– Starts automatically whenever the HMC is started– Requires user login prior to access– HMC V7.310 introduced Browser based user interface

– (eliminates need for WebSM for remote access & management)

Remote GUI (on network PC)– Uses an installable standalone remote client application (WebSM Client)

– Windows (NT,XP) or Linux– Downloadable as an installable application directly from the HMC, via web browser

– Also supported from one HMC to another, also to/from AIX 5L– Can be SSL secured through public/private key files

– Generate on the HMC, and transfer to client systems

Local Command Line (on HMC)– Launched from the HMC desktop– Linux based commands - Restricted to a set of supported HMC commands

Remote Command Line (on network PC)– Accessed through encryption-protected Secure Shell (SSH)– Key files can be set up and exchanged to avoid password prompts

– Very useful for automation and scripting without human intervention

Page 41: HMC+and+V7+System+p VUG

41 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC V6 and earlier - Remote GUI management requires WebSM:(Web-based System Manager)

Two WebSM clients available:– Web-based System Manager Remote Client– Web-based System Manager Remote Client for Java Web Start – Either client works the same after installation

Remotely access your HMC by installing WebSM client on your PC workstation

WebSM client allows you to manage your system from virtually anywhere – Up to 5 remote clients can be logged in simultaneously

The HMC and WebSM can negotiate SSL encryption for additional security

Some tasks not available using the remote client– These tasks include restarting the HMC interface and configuring System Manager Security for

certificate authority or viewing overview and status information. – Some of these functions are available remotely using SSH command line interface

– V7.310 remote management resolved some of these limitations, such as rebooting the HMC

HMC V7 and after - Remote GUI access via Secure Browser - WebSM is no longer needed or supported.

Page 42: HMC+and+V7+System+p VUG

42 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

WebSM client - http://HMC Name/remote_client.htmlExample to download WebSM client: http://myHMC.IBM.com/remote_client.html

Page 43: HMC+and+V7+System+p VUG

43 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Starting the WebSM Remote Client

Web-based System Manager Remote Client.lnk

Desktop icon

Page 44: HMC+and+V7+System+p VUG

44 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC V6 and earlier GUI Interface – using WebSM

Manage HMC configuration, users,

services, ...

Guide setup wizard and online documents

Update your Licensed Internal Code

Set up security for remote GUI access

Service tools to analyze and repair

Manage your servers and partitions

Page 45: HMC+and+V7+System+p VUG

45 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Remote access to V7 HMC using most any standard browser• Secure HTTPS• Logon window can be customized• Managed systems status indicators

Page 46: HMC+and+V7+System+p VUG

46 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC V7.3xx User interface changed to Browser based

Some new features

More to come on Data replication

Page 47: HMC+and+V7+System+p VUG

47 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

V7R3.x.x Rollout

Overview – General HMC Function Set– V7R3.1.0 Content– V7R3.2.0 Content– V7R3.3.0 Content

Details – Selected 3.1 functions – Selected 3.2 functions – Selected 3.3 functions

Page 48: HMC+and+V7+System+p VUG

48 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC R7V3.1.0 – Web UI, Quick Overview Motivation / Strategy for new GUI:

– Real http / https GUI – no need for WebSM interface– Leverage modern, familiar UI paradigms and technologies– Unify HMC family of user interfaces

– z,p,i,Storage and Integrated Virtualization Manager (IVM)– Consistent User Experience across HMC and IBM Web UI family

Navigation – Simplification – some tasks rearranged

– Improving task discovery – Reduce task depth – Consistent task placement – Consistent task categorization – Display more information in main views – Simplify complex functional areas

– Task list available multiple ways (Task list, Tasks button, right click)

New Functions – Status Bar– View Users logged on– Disconnect / Reconnect – Custom Groups– Ability to customize which columns are displayed– Table filtering and sorting

– Replaces tree structure

Page 49: HMC+and+V7+System+p VUG

49 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Remote access disabled by default– Task to enable/disable remote access – User Profiles task to enable for specific users

Security– Certificate based SSL security for encrypted

communications– Certificate Management task

Browser CompatibilityLinux Windows

Mozilla Firefox 1.5.x + 1.5.x +Microsoft Internet Explorer 6.x +

HMC R7V3.1.0 – Web UI, Browser Support

Page 50: HMC+and+V7+System+p VUG

50 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC V7R3.1.0 – Integrated Virtual Ethernet (aka HEA)

What’s in a Name– Integrated Virtual Ethernet (IVE) – External name in marketing & other documentation – Host Ethernet Adapter (HEA) – Name used on user interfaces

New Hardware capability with all POWER6 servers except 595– Provides accelerated Ethernet connectivity

– Essentially, a system with HEA has several integrated Ethernet adapters, called logical ports. – Can be assigned to one or more partitions.

– Integrated on most POWER6 system (all but the POWER6 595) – Several variations of physical, external ports

– Dual 1 Gbit copper, supporting 10BASE-T, 100BASE-T, 1000BASE-T– Quad 1 Gbit copper , supporting 10BASE-T, 100BASE-T, 1000BASE-T– Dual 10 Gbit fiber, supporting 10GBASE-SR or 10GBASE-LR

– Logical Ports – Up to 32 logical ports, but can also be configured as 1, 2, 4, 8, 16 logical ports – Controlled by parameter called “Multi-Core Scaling Value”

Page 51: HMC+and+V7+System+p VUG

51 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC V7R3.1.0 – Integrated Virtual Ethernet (aka HEA)

Page 52: HMC+and+V7+System+p VUG

52 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC V7R3.1.0 – Shared Dedicated Capacity - before

0

25

50

75

100

125

150

175

200

0.5 Uncapped 20.5 Uncapped 1Wasted Dedicated1-way Dedicated

– Consider a 2-way server with 1-way dedicated partition with variable workload (between 0% and 100%).

– Add two evenly weighted 1-way uncapped partitions that are CPU bound.

– Each uncapped partition will share the remaining physical processor even though each can consume an entire processor.

– The excess capacity on the dedicated processor is wasted.

0

25

50

75

100

125

150

175

200

0.5 Uncapped 20.5 Uncapped 1Wasted Dedicated1-way Dedicated

– With the new support, dedicated partitions with unused cycles will donate those unused cycles to the uncapped partitions.– Donated cycles do not increased a (shared

processor) partition’s entitled capacity.

– The uncapped partitions will share all the available cycles: – They consume an entire processor if available

(when dedicated at 0%) and – Split a processor when the dedicated processor is

fully utilized.

– The total processor capacity in the system is better utilized.

– Dedicated proc LPs still maintain their perf characteristics and predictability

Page 53: HMC+and+V7+System+p VUG

53 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC R7V3.1.0 – HMC Management EnhancementsNew monhmc command

– Can gather disk space usage and system memory usage

– Some specific processes on the HMC are monitored

Clickable SRCs– The new browser-based interface allows a user

to click on an SRC or Progress Code and pop-up a description of the SRC.

Data replication– This is an application from System z HMC that

allows customer call-home configuration to be replicated between HMCs

3rd party certificates– A customer can now install their own 3rd party

certificates to use with remote connections to the HMC.

Selectable VPN– Allow choice of IP interface to use for the VPN

connection back to IBM.

Page 54: HMC+and+V7+System+p VUG

54 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Selectable SRC for more detail information

Page 55: HMC+and+V7+System+p VUG

55 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Server Management – Discovery / Inventory of I/O Devices (aka Hardware Discovery)– Enhanced System Plan information

– Uses Hardware Discovery (item above) and– OS round-tripping

– Concurrent GX+ adapter add & cold repair for L4 / ML– Redundant Service Processor for ML – Enabled at EM320 – Energy Scale (Active Energy) Support – Scheduled Operations for Utility Capacity on Demand

Virtualization Management– Partition Mobility (between servers managed by same HMC)– Multiple Shared Processor Pool Support

HMC Management – User Authentication via Kerberos – Enhanced HMC Monitoring – Ongoing HMC Performance Improvements

Power HMC – V7R3.2.0 Content Overview

Page 56: HMC+and+V7+System+p VUG

56 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC V7R3.2.0 – Hardware Discovery OverviewThis function requires 320 level system firmware (or newer).

Functional improvements: – Provides capability to collect I/O device information before partitions and OS’s

are configured or booted to make configuration easier. – Provides HMC users more detailed view of slot contents especially child

devices.– Can view storage device information (what’s on the SCSI bus). – Can view Ethernet MAC addresses and FibreChannel WWN’s via HMC. – Can even be done before partitions are configured.

– Provides more detailed inventory to System Plan Tool to verify system configuration and validate customer orders.

Hardware Discovery can be performed three ways1. Initial Power On (after system leaves IBM): Hardware Discovery performed

automatically. • Only when system is in non-partitioned mode and IO data hasn’t already been collected.

2. New Power On “Hardware Discovery” option.• I/O data collected for both assign and unassigned I/O.

• Existing LPs booted into Hardware Discovery; later returned to (bootable) state.• Special LP used to collect I/O data for unassigned I/O.

• System left in Operating state (no auto-boot of partitions).3. Is initiated automatically by System Plans tool. (see next function)

Page 57: HMC+and+V7+System+p VUG

57 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

User initiated Hardware Discovery from the HMC.

System Powers On and collects IOR data utilizing service partition.

System left in “Operating” state upon completion.

Partition auto-boot settings not enforced on this type of power on (are persisted for future).

When to use this option:

After repair and verify.

After attaching new expansion unit.

After firmware upgrade.

HMC V7R3.2.0 – HW Discovery, New Power On

Checkbox appears with

managed systems that are Hardware

Discovery Capable

Page 58: HMC+and+V7+System+p VUG

58 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

IOR Collection LPAR– Automatically creates service

partition.– Hardware Discovery state.– Persist for 1-20 min.– Deleted upon completion.

Existing LPAR

– Hardware Discovery state.– Returned to previous

(bootable) mode upon completion.

HMC V7R3.2.0 – HW Discovery, User Visibility

New tab under Slot Details launched from System/Partition/Partition Profile Properties I/O table.High level view intended to be more of a “Device Manager” for administrators.

Page 59: HMC+and+V7+System+p VUG

59 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Create System from HMC – (export / import SPT)

The System Planning Tool (SPT) is free, it runs on a stand-alone workstation and enables the user to design a new system. Select the Machine Type and Model, processors, memory and IO hardware, and design the partitions. This can be sent to IBM order processing and manufacturing can build to the plan specifications. The SPT output can also be imported by the HMC and the DEPLOY option can automatically create the partitions.http://www-304.ibm.com/systems/support/tools/systemplanningtool/

Page 60: HMC+and+V7+System+p VUG

60 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Create a System plan from the HMC

Summary information: Partitions, processors, shared pools, memory, memory page-

size, and attached I/O towers… Now we can see the devices details below the IOA

Page 61: HMC+and+V7+System+p VUG

61 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC Generated System Plan at V7.330, on POWER6 can see more

of the device level details

Page 62: HMC+and+V7+System+p VUG

62 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC V7R3.2.0 – Hardware Discovery CLI

lssyscfg –r sys displays new cec capability for IOR, hardware_discovery_capable

chsysstate –r sys includes new option onhwdisc

lssyscfg –r lpar displays new lpar definition state for IOR in the lpar_env and lpar_type attribute.

lssyscfg –r lpar displays new VSP definition state for IOR in the stateattribute.

lssyscfg –r prof displays new lpar definition state for IOR in the lpar_envattribute.

lshwres –r io –rsubtype includes new type slotchildren to list IOR slot information

Page 63: HMC+and+V7+System+p VUG

63 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC V7R3.2.0 – Energy Scale Support

HMC / ASM provides a small subset of the EnergyScale features.– Enable / Disable of Power Saver Mode– Schedule Operation for Power Saver Mode– Pass through channel for PowerExecutive / Director

PowerExecutive / Director provides the complete set of EnergyScale functions.

– PowerExecutive was originally a power management plugin for System x. It is now the official management console for EngeryScale feature

Page 64: HMC+and+V7+System+p VUG

64 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC V7R3.2.0 – Energy Scale CapabilitiesHMC displays 2 capabilities for power saver mode:

– Firmware power saver capable –Whether the firmware running on the server is capable for power saver mode

– Hardware power saver capable –Whether the hardware supports the power saver mode.

HMC User Interfaces: – GUI (Managed system properties

panel) and – Command line (lssyscfg -r sys)

Page 65: HMC+and+V7+System+p VUG

65 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC V7R3.2.0 – Energy Scale, Power Saver ModeWith power saver capable systems, users can enter static power save through the power saver mode configuration task.

With power saver mode enable, the processing utilization reporting might not be accurate if the OS does not have the proper support.

Commands for power saver mode: chpwrmgmt and lspwrmgmt

Scheduled Operation for Power Saver Mode

Page 66: HMC+and+V7+System+p VUG

66 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Terminology

Additional capacity assigned to a virtual pool for the purpose of reserving uncapped cycles for the VSPP’s use. Must be less than Maximum Pool Capacity. Cannot be stolen by the HMC during partition activation. The units are processor units and for HMC users the granularity is 0.01 processor units.

Reserved Pool Capacity

A computed quantity – not user specified.This is the number of CPU cycles guaranteed to be available to the set of partitions in the virtual pool. It is equal to the sum of the entitled capacities of the partitions in the VSPP (pending processor units of the active and inactive partitions) plus the Reserved Pool Capacity for the VSPP. Must always be Equal to or smaller than Maximum Pool Capacity. The units and granularity are the same as Reserved Pool Capacity.

Entitled Pool Capacity

Maximum Pool Capacity Maximum CPU cycles that can be consumed by the partitions in a VSPP (whole number of proc units).

HMC V7R3.2.0 – Shared Processor Pools

Active Dedicated Processor

LP1

Dedicated Processor

LP2Physical Shared Processor Pool

VSPP Pool 0 (default pool) VSPP Pool 2VSPP Pool 1

One Physical Shared Processor Pool (PSPP) – Spans all VSPPsComprised of all of licensed CPUs that are

– Not assigned to an active dedicated processor partition– Assigned to active dedicated processor partition that is capable of donation– Assigned to inactive dedicated processor LPs and system administrator has chosen to

make CPUs available for shared processor work when the LP is powered offVSPP Capacity

Page 67: HMC+and+V7+System+p VUG

67 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Prior to this Multiple VSPP support, all shared processor partitions were in the one and only Virtual Shared Processor Pool, pool 0, also known as the default pool

VSPP attributes:Pool ID – ranging from 0 to 63User Defined Name

“DefaultPool” for pool 0; can’t be changedReserve Pool Capacity

Exception: no Reserve Capacity for pool 0. Can’t be modified, not displayedMaximum Pool Capacity

Exception: pool 0 varies to cover remainder of PSPP. Can’t be modified, not displayedMaximum value (for non-default VSPPs) is maximum system processor capacity

VSPP Pool FunctionVSPPs are configured and unconfigured, not created or deleted, by setting Maximum Pool CapacityAll partitions must be moved out of a VSPP to unconfigure it, i.e. set the Maximum Capacity to zeroVSPP modifications can be done when the system is in the Operating or Standby states, and take effect right awayInitialize Profile Data will initialize all VSPPs, i.e. setting Maximum Pool Capacity and Reserved Pool Capacity to zero and pool names to the default names, after all the partitions are deletedDLPAR Add and Move of shared processing units will fail if target VSPPs Maximum Capacity is exceeded

VSPP Management

HMC V7R3.2.0 – Shared Processor Pools, VSPP Functions

Page 68: HMC+and+V7+System+p VUG

68 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Configure Shared Processor Pools

Page 69: HMC+and+V7+System+p VUG

69 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Configure shared pools – edit partition profile or on create

Page 70: HMC+and+V7+System+p VUG

70 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC V7R3.2.0 – Kerberos Authentication, Overview

3. HMC sends principal name / TGT Request to KDC.

5. TGT returned to HMC

Kerberos KDC

(Key Distribution Center) Server

System i/p Server(s)

HMC6. Client (HMC) verifies

TGT with supplied PW.

2. User logs in to HMC (either local or remote)

Supplies User ID & PW

1. Remote User establishes https

session to HMC.

4. KDC computes encrypted TGT

using password.

. . .

7. If PW passes, all HMC operations proceed as normal. No further usage of Kerberos / TGT.

Remote Workstation (Web browser)

Kerberos TGT (Ticket Granting Ticket)

Page 71: HMC+and+V7+System+p VUG

71 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC supports MIT Kerberos V5.

Must have hmcsuperadmin authority to configure Kerberos Client IP on HMC.

Must configure (Extended Network Time Protocol) XNTP correctly and make sure both i/p HMC's date/clocks are in sync with all Kerberos KDCs.

HMC V7R3.2.0 – Kerberos Authentication, Configuration

Support both manual login as well as SSH (CLI)

SSH include Kerberos password-less login– Requires HMC Kerberos service key to be set-up– Requires client machine to support ssh GSSAPI (Generic Security Services Application

Programming Interface). This is usually found in the *nix ssh configuration file (hint: look for “GSSAPI” and enable).

– Requires client machine to be configured for Kerberos (i.e., client).– Requires client to obtain “forwardable” credentials prior is issuing ssh command (e.g., kinit

–f foobar@REALM).– Ssh supported GSSAPI options:

ssh -o PreferredAuthentications=gssapi-with-mic foobar@<hmc hostname>ssh -o PreferredAuthentications=gssapi foobar@<hmc hostname>

Page 72: HMC+and+V7+System+p VUG

72 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Option for access authentication:Local, Kerberos, LDAP

Page 73: HMC+and+V7+System+p VUG

73 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC V7R3.3.0 – User Data ReplicationData Replication– Automatically replicate changes made on one HMC

to other HMCs.

Replication Types– Peer-to-Peer– Master-to-Slave

– Multiple masters supported

Data which can be replicated– Customer information data

– Administrator, System, Account information

– Group data– All user-defined group definitions.

– Modem configuration data – Configure modem for remote support.

– Outbound connectivity data – Configure local modem to RSF – Enable an internet connection – Configure to an external time source

– User Profile data– User account and access configuration

– Kerberos, LDAP configuration data– Centralized user authentication server configuration

Page 74: HMC+and+V7+System+p VUG

74 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Data Replication only available via GUI (no CLI)

Only hmcsuperadmin users allow to configure data replication

Enable Data Replication

HMC Management => Manage Data

HMC V7R3.3.0 – User Data Replication

Select Replication SourceHMC Management =>

Manage Data Replication

Select Replication Data Types

Synchronize the replicated data

Save the configuration

Page 75: HMC+and+V7+System+p VUG

75 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

HMC V7R3.3.0 – User Replication, OverviewData Replication

Replication Configuration

User Profile Replication Discussion

Page 76: HMC+and+V7+System+p VUG

76 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

• IPv6 supported on “internet” connection only.• Not supported on server connections in 3.3.0.

• UI changes • Several CLIs updated• Only one GUI panel changed: under Change Network Settings:

• HMC management->Change Network Settings->LAN Adapters->Details

• “Basic Settings” tab has changed• New “IPv6 Settings” tab

HMC V7R3.3.0 – IPv6 Support, Overview

IPv6 Settings tab

Page 77: HMC+and+V7+System+p VUG

77 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

For more informationhttp://publib.boulder.ibm.com/infocenter/systems/scope/hw/index.jsp

Page 78: HMC+and+V7+System+p VUG

78 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Bookmark - the New HMC home pagehttps://www14.software.ibm.com/webapp/set2/sas/f/hmc/

Page 79: HMC+and+V7+System+p VUG

79 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Support for HMC – on POWER Systems - Referenceshttps://www14.software.ibm.com/webapp/set2/sas/f/hmc/resources.html

HMC Version 7 specifically or to HMC for POWER6 and POWER 5 servers in general.• HMC Version 7 Installation and Configuration Guide for the Hardware Management Console• HMC Version 7 Operations Guide for the Hardware Management Console and Managed Systems • HMC Version 7 Cumulative PTF History and Readme

Includes PTF-specific information, including verification information for package downloads and installation. Also includes general information on HMC Version 7 fixes, enhancements, known issues and education.

• HMC V7 R3.2.0 Command line specificationManual pages for HMC restricted shell command line.

• HMC V7 R3.1.0 Command line specification• IBM service strategy and best practices

Various white papers on best practices, including HMC.• HMC function and hardware prerequisites for HMC Version 7

Lists the supported functions, servers, and HMC hardware for each Code Level for HMC for IBM Systems with POWER6 processors.

• IBM System Planning ToolThe IBM System Planning Tool (SPT) is the next generation of the IBM LPAR Validation Tool (LVT). It contains all of the function from the LVT and is integrated with the IBM Systems Workload Estimator (WLE). System plans generated by the SPT can be deployed on the system by the Hardware Management Console (HMC).

• MIB file for IBM Systems managed by an HMCFile for IBM Systems managed by an HMC. The MIB for HMC defines the Problem Event SNMP traps generated by the HMC.

Page 80: HMC+and+V7+System+p VUG

80 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Education from IBM Resource Linkhttps://www-01.ibm.com/servers/resourcelink/hom03010.nsf?OpenDatabase

Page 81: HMC+and+V7+System+p VUG

81 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Information Centers, Redbooks and more

The POWER Systems Hardware Info Centerhttp://publib.boulder.ibm.com/infocenter/eserver/v1r2s/en_US/index.htmIBM iSeries™ Hardware Management Console Frequently Asked Questions

– http://www-1.ibm.com/support/docview.wss?uid=nas148859a914db132a586256f42006003a7&rs=110

HMC - Support for UNIX servers and Midrange servers– http://www14.software.ibm.com/webapp/set2/sas/f/hmc/home.html

HMC Best Practices –https://www14.software.ibm.com/webapp/set2/sas/f/best/hmc_best_practices.pdf

iTC class room education –http://www-03.ibm.com/servers/eserver/iseries/service/itc/educ.html

LPAR Redbook –http://www.redbooks.ibm.com/redbooks.nsf/RedpieceAbstracts/sg248000.html?Open

Page 82: HMC+and+V7+System+p VUG

82 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

The End

Thank You !

Page 83: HMC+and+V7+System+p VUG

83 © 2008 IBM Corporation

IBM Power Systems - System p Virtual User Group

Trademarks and Disclaimers

© IBM Corporation 1994-2005. All rights reserved.References in this document to IBM products or services do not imply that IBM intends to make them available in every country.The following terms are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both:

Lotus, Freelance Graphics, and Word Pro are registered trademarks of Lotus Development Corporation and/or IBM Corporation.Domino is a trademark of Lotus Development Corporation and/or IBM Corporation.C-bus is a trademark of Corollary, Inc. in the United States, other countries, or both. Java and all Java-based trademarks are trademarks of Sun Microsystems, Inc. in the United States, other countries, or both. Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both. ActionMedia, LANDesk, MMX, Pentium and ProShare are trademarks of Intel Corporation in the United States, other countries, or both. UNIX is a registered trademark of The Open Group in the United States and other countries.SET and the SET Logo are trademarks owned by SET Secure Electronic Transaction LLC. Other company, product and service names may be trademarks or service marks of others.Information is provided "AS IS" without warranty of any kind.All customer examples described are presented as illustrations of how those customers have used IBM products and the results they may have achieved. Actual environmental costs and performance characteristics may vary by customer.Information in this presentation concerning non-IBM products was obtained from a supplier of these products, published announcement material, or other publicly available sources and does not constitute an endorsement of such products by IBM. Sources for non-IBM list prices and performance numbers are taken from publicly available information, including vendor announcements and vendor worldwide homepages. IBM has not tested these products and cannot confirm the accuracy of performance, capability, or any other claims related to non-IBM products. Questions on the capability of non-IBM products should be addressed to the supplier of those products.All statements regarding IBM future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only. Contact your local IBM office or IBM authorized reseller for the full text of the specific Statement of Direction.Some information in this presentation addresses anticipated future capabilities. Such information is not intended as a definitive statement of a commitment to specific levels of performance, function or delivery schedules with respect to any future products. Such commitments are only made in IBM product announcements. The information is presented here to communicate IBM's current investment and development activities as a good faith effort to help with our customers' future planning.

Performance is based on measurements and projections using standard IBM benchmarks in a controlled environment. The actual throughput or performance that any user will experience will vary depending upon considerations such as the amount of multiprogramming in the user's job stream, the I/O configuration, the storage configuration, and the workload processed. Therefore, no assurance can be given that an individual user will achieve throughput or performance improvements equivalent to the ratios stated here.

Photographs shown are of engineering prototypes. Changes may be incorporated in production models.

xSeriesRationalPOWER5iSeriese(logo)serverDB2

POWER4

POWER

OS/400

Notes

MQSeries

Lotus

WebSphereQuickplaceIBM(logo)e(logo)businessAS/400e

TotalStoragepSeriesIBM Virtualization Enginee business(logo)AS/400

i5/OSTivoliPOWER6IBMDominoAIX 5L (logo)

400ThinkPadPOWER HypervisorHipersocketsDataPropagatorAIX 5L

zSeriesS/390Power EverywhereEnterprise Storage ServerDB2 OLAP ServerAIX/L

z/OSRS/6000Power ArchitectureeServerDB2 UniversalAIX