HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links...

87
0 © Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in part without the prior written permission of IBM. © Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in part without the prior written permission of IBM. HMC Enhanced UI Deep Dive Allyn Walsh, Hari G M & S. Ashok [email protected] [email protected] [email protected]

Transcript of HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links...

Page 1: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

0© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

HMC Enhanced UI Deep DiveAllyn Walsh, Hari G M & S. Ashok

[email protected]

[email protected]

[email protected]

Page 2: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

1© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

• PowerVM Simplification Enhancements

• New Login Page

• Classic vs Enhanced Option

• Navigating through Enhanced UI

• Setting up system using System Template

• Creating VIOS & Partition (Templates)

• Managing Partition

• Virtual Storage Management

• Virtual Network Management

• Performance & Capacity Monitoring

• HMC Management

• Serviceability

Session objectives

1

Page 3: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

2© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

PowerVM Simplification Enhancements

2

Page 4: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

3© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Enhanced UI Roadmap

Performance Improvements

HMC V8 R8.2.0 - Tech Preview

HMC V8 R8.3.0

GA

HMC V8 R8.4.0Storage Topology

SSP Tiers & Failure Groups

HMC V8 R8.5.0 SRIOV & Virtual NIC

topology diagramsTablet Support

HMC V8 R8.6.0Topology Diagram Enhancements

Task Pod (Tasks Log)New option to create partition

HMC V8 R8.6.0 SP1New Login Page

3

Page 5: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

4© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Performance Enhancements in HMC V8 R8.5.0

• Response time above in seconds• Configuration used:

• CR6 HMC (with 16GB of RAM)• 6 Managed Systems (1 E870, 3 p260s, 2 p460+) and some emulated instances

4

Page 6: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

5© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Performance Enhancements in HMC V8 R8.6.0

• Response time above in seconds• Configuration used:

• CR9 HMC (with 16GB of RAM)• 5 Managed Systems (S824 machines: 8286-42A)• 500 LPARS total (100 partitions per system)

5

Page 7: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

6© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

New Login Page – HMC V8 R8.6.0 SP1 onwards

New design with easy access to social media and app links Developer Works Blogs on PowerVM – Available only when accessing HMC remotely

User Credentials

System/Partition Status

Social Media & App Links PowerVM LinkedIn Group

6

Page 8: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

7© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

New Login Page – HMC V8 R8.7.0 – No Classic option

New design with easy access to social media and app links Developer Works Blogs on PowerVM – Available only when accessing HMC remotely

User Credentials

System/Partition Status

Social Media & App Links PowerVM LinkedIn Group

7

Page 9: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

8© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Classic vs Enhanced – Terminology & Menus

HMC Classic Interface HMC Enhanced UI Interface

Create Partition Templates (Resources > All Systems > Server > View System Properties > System Actions > Templates)

Partition Properties, DLPAR Manage Partition (Resources > All Systems > Server > Partition > * (Properties/Processors/Memory/Physical IO/Virtual Storage/Virtual Networks/Virtual NICs)

Server > Configuration > Virtual Resources Resources > All Systems > Server > PowerVM

Server > Hardware Information > Adapters Resources > All Systems > Server > PowerVM > Hardware Virtualized I/O

Server > Performance Resources > All Systems > Server > View System Properties > Capacity > Performance Dashboard

Server > Properties Resources > All Systems > Server > View System Properties

Partition > Configuration > Manage Profiles Resources > All Systems > Server > Partition > Partition Actions > Profiles

8

Page 10: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

9© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Navigating through Enhanced UI

9

Page 11: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

10© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Navigating through Enhanced UI – Launch Page – Gallery View

Tool Bar

Resource Path

Quick Filter (Filter by fields of specific resource)

Global Search (Search across all resources)

Pins – Like Shortcuts/Bookmarks

Task Log

Gallery, Table & Relational Views

Pin the page

10

Page 12: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

11© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Navigating through Enhanced UI – Getting Started

11

Page 13: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

12© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Navigating through Enhanced UI

Resource Menus

About HMC – Version, Build Level, MTMSKC, Read Me, Getting Started,

About Links

• Easy access to resources (all systems view, all partitions view), read me and version info• Multiple options to navigate through resources

12

Page 14: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

13© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Navigating through Enhanced UI – Systems All Actions

13

Page 15: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

14© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Navigating through Enhanced UI – Systems Actions & Options

14

Page 16: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

15© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Setting up a system and initial configuration

15

Page 17: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

16© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

System Templates

To work with system templates, use the Templates and OS Images option. Deploy System Template can be launched in 2 ways1. From Template

Library – In this case, Wizard would ask you to choose the system for deployment

2. System > View All Actions > Deploy System Template

Template Library View

16

Page 18: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

17© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

System Templates • Use System Template to

• Set system settings like LMB Size, Power Off Policy, Firmware Start Policy

• Create Shared Processor Pool, Shared Memory Pool as needed

• Configure IO adapters (SRIOV, HEA)• Create Virtual IO Server (VIOS) and Install VIOS• Configure Network Settings (Create Network

Bridge, Virtual Network)• Configure Storage

Note: When system template deploy is being used, it would initialize the system (i.e., delete all the partitions on the system) first and then performs above mentioned configuration.

Only certain specific details are allowed to be edited during the deploy process, so its important to edit the template and have the required configuration before deploy.

If you would like to Add VIOS to an existing system, use the Create Virtual IO Server Option in Resources > All Systems > System > Virtual IO Servers

17

Page 19: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

18© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

System Templates – Launch from Template Library

18

Page 20: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

19© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

System Templates

When you click on Reset Button on the selected system, message is displayed as to what action would be taken to reset the system

19

Page 21: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

20© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

System Templates

• Use the start button to start the system configuration setup

20

Page 22: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

21© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

System Templates

• Choose install options and specify install details• Once install is complete and RMC connection becomes active, accept the license & you can configure

Network (Network Bridge) & Storage (Like attach to a SSP) on the VIOS

21

Page 23: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

22© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Create & Activate Partitions/Virtual IO Server

22

Page 24: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

23© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Partition Templates

How to Create Partition Templates ? • HMC provides Canned/Starter Templates (cannot be edited/deleted)• Existing partition configuration can be captured as user defined template• Starter templates can be copied and user defined templates can be created.

Actions with partition templates• View the Templates details• Edit the partition templates to customize the resources allocated to a partition. For example, you can

customize the partition template to be used for a particular workload or operating system type. You can change configurations like general settings, processor & memory, Virtual Network, Virtual Storage, Physical IO, Hardware Virtualized IO, Tagged IO.

• Copy a template and create a new one. For example, you can copy a starter template and create a new one to customize for the partition requirements

• Export the template which can later be imported on to another HMC. • Deploy the template to create, configure and activate the partition. • Delete the template

23

Page 25: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

24© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Create Partition using Templates

• Once template & managed system is selected, a validation of template against the selected managed system is performed (Validation for capabilities, available CPU/Memory etc.,)

• Logical Partition Configuration Summary Tab : Partition Id, Name, Shared Processor Pool Name• Physical IO : Physical IO, HEA, SRIOV (Pre-selected Physical IO will be shown if Use Captured IO option is used)

• Network Configuration : Pre-selected Virtual Networks (Use Captured IO) or Available Virtual Networks• Virtual NIC Configuration : Pre-selected Virtual NIC (Use Captured IO) or Available VNIC• Virtual Storage Configuration :

• Virtual SCSI – Physical Volumes and Shared Storage Pool Logical Units• Virtual Fibre Channel

• IBM I Tagged IO• Summary :

• Activate or Apply Configuration

24

Page 26: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

25© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Create Partition – Launch from Managed System Partitions View

25

Page 27: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

26© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Create Partition – Quick/Simple Create (HMC V8 R8.6.0 or later)

Default Configuration for quick create :

1.Shared processor with

1. Minimum, Desired and Maximum Virtual Processors as 1.

2. Minimum, Desired and Maximum Processing Units as 0.1.

3. Uncapped sharing mode with weight as 128.

2.Memory with 1. Minimum memory as 1GB2. Desired memory as 1GB3. Maximum memory as 4GB

3.Maximum Virtual Adapters as 10

• Create a partition with minimal settings, helps in creating multiple partitions faster

Note : You need to attach the storage/network using manage partition before booting the partition

26

Page 28: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

27© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Create Partition – Launch from Templates Library View

27

Page 29: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

28© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Create Partition using Templates – LPAR Config

• Only partition name and ID can be edited at this step. Other details have to be specified/edited in the template itself

28

Page 30: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

29© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Create Partition using Templates – Physical IO

29

Page 31: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

30© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Create Partition using Templates – Virtual Network

Deploy process creates the Virtual Ethernet adapter with the vlan & vswitch of selected virtual networks

30

Page 32: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

31© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Create Partition using Templates – Virtual NIC

31

Page 33: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

32© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Create Partition using Templates – Virtual Storage• User needs to select only the storage or port to be assigned to the partition• Deploy process creates the required client & server adapter pair and maps storage/fc port• Selecting Assigned Physical Volumes option lists the Physical Volume which are already in use

• can be used when the same physical volume has to be shared across multiple partitions (Cluster or PowerHA or IBM DB2 Cluster Services)

• Edit Connections can be use to specify server adapter id or select redundancy

32

Page 34: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

33© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Create Partition using Templates - Summary

Review the settings of the partition using the summary page before starting the create/activate process

33

Page 35: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

34© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Create Partition using Templates – Activate/Apply

• Choose Create & Apply, if you want to create all the configuration and boot later. You can later activate the partition using the activate action under partition

34

Page 36: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

35© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Create Partition using Templates - Notes

• Create partition from template is a halt on first failure operation. • After the partition template and managed system is selected, the wizard validates the configuration of

partition template against the selected managed system. Validation might fail in case of, • The capability selected in the template is not supported in the system• Non-availability of the requested configuration.• If any requested configuration is greater than available configurations. [Such as, requested

memory, processor configuration is greater than the processor or memory available.]• In case of failure, error message is shown and wizard waits for you to cancel the operation or navigate back

to make the changes and re-attempt the operation.• Not all attributes/options are editable as part of the create/deploy partition template wizard.• A partition template can be edited to choose the required configuration before deploy.

35

Page 37: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

36© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Activate Partition

• Choose activate with profile or current configuration• Network boot supported for AIX/Linux Logical Partitions

36

Page 38: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

37© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Create Virtual IO Server

A Virtual I/O Server partition can be created using,

1. System template

• Deploy System Template can be used to configure the system, create VIOS partitions specified in the system template, configure SRIOV, Physical I/O, Network Storage etc. and install the VIOS.

Note: When system template deploy is being used, it would initialize the system (i.e., delete all

the partitions on the system) first and then performs above mentioned configuration.

2. Create Virtual I/O Server wizard.• Add/create new VIOS Partitions as needed by using this option outside of the System Template

Deploy.• Create the VIOS partition and apply the configuration or proceed with installation of OS after the

creation

37

Page 39: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

38© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Launch Create Virtual IO Server

38

Page 40: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

39© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Create Virtual IO Server

39

Page 41: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

40© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Create Virtual IO Server

40

Page 42: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

41© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Create Virtual IO Server

41

Page 43: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

42© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Create Virtual IO Server

42

Page 44: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

43© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Manage Partition

43

Page 45: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

44© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Manage Partition

• Resources -> All Systems -> <System Name> -> Partitions -> <Partition Name> • Resources -> All Partitions -> <Partition>• Work with Partition Properties, Capabilities, CPU, Memory, IO, Virtual IO (Storage,

Network, VNIC), Topology Diagrams• With the new model , user needs to work only with the partition and not worry about

profiles. The partition settings can be modified when partition is active or inactive

44

Page 46: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

45© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Manage Partition - Actions and Menu Options

45

Page 47: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

46© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Manage Partition - Quick Info

46

Page 48: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

47© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Where is DLPAR performed? - Manage Partition - Properties

47

Page 49: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

48© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Manage Partition – Processor

48

Page 50: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

49© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Manage Partition – Memory

49

Page 51: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

50© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Manage Partition – Physical IO

50

Page 52: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

51© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Virtual Networks

51

Page 53: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

52© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Virtual Networks

Enhanced UI Model Equivalent Legacy Model

Virtual Switch Virtual Switch

Virtual Network (New) VLAN + Vswitch Combination

Network Bridge Single SEA ( Non – Failover) or SEA Pair ( failover/ load balancing)

Load Group Trunk Adapter on SEA (non failover)or

Pair of Trunk Adapters with exact same configuration across two failover/load balancing SEAs

Link Aggregation Combine physical ports to make one single data path for higher bandwidth and to provide redundancy

Add Virtual Network to System

Internal or Bridged Network

Attach Partition to Virtual Network

Virtual Network Flow :

Tagged or Un-tagged Network

52

Page 54: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

53© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Virtual Network – View System Virtual Networks

53

Page 55: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

54© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Virtual Network – Add Virtual Network

Bridged & Untagged network

• Untagged – VLAN ID is used as PVID of the trunk adapter/SEA• Tagged – VLAN ID is used as additional VLAN ID of trunk adapter and you need to specify the

PVID of SEA in the next panel if a new Network Bridge is created. • Use Advanced settings to choose a different VSwitch or Create a new one

54

Page 56: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

55© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Virtual Network – Add Virtual Network

• Specify failover or load sharing options• If Load sharing is enabled, specify the 2nd load group VLAN ID (PVID of 2nd trunk adapter)

55

Page 57: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

56© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Virtual Network – Add Virtual Network

• Choose the adapters and specify the IP address to be configured on the SEA interface(s)

56

Page 58: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

57© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Virtual Network – Add Virtual Network

• Use adapter view to choose slot numbers of trunk adapters, if needed

• Clicking on Finish will start the add network process and • Create a virtual network

(vlan + vswitchcombination)

• Create Trunk adapter(s) in the VIOS(s)

• Create SEA(s) by associating the selected physical adapters and trunk adapters

• Configure IP(s), if specified, for the SEA interface

57

Page 59: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

58© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Virtual Network – Adding Virtual Network to Partition

Add or Remove Virtual Network

58

Page 60: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

59© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Virtual Network – Adding Virtual Network to Partition

• “Show and assign new virtual ethernet adapters” allows you to see adapter id & specify adapter id for adding a new virtual network

59

Page 61: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

60© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Virtual Storage

60

Page 62: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

61© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Virtual Storage – View Virtual Storage

Resources > All Systems > <System Name> > Partitions > <Partition Name> > Virtual Storage

Resources > All Partitions > <Partition Name> > Virtual Storage

61

Page 63: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

62© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Virtual Storage – Add Virtual SCSI• User needs to only select the storage and HMC creates the required server/client adapter pair and maps storage• Use Edit Connection to work with redundancy and specify/select slot id• Selecting Show assigned physical volumes lists the physical volumes already in use

• Can be used when the same physical volume has to be shared across multiple partitions (Cluster or PowerHA or IBM DB2 Cluster Services)

Virtual Target Device name

62

Page 64: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

63© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Virtual Storage – Add Virtual FC

• User needs to only select the FC Port and HMC creates the required server/client adapter pair and maps FC port

• Use Edit Connections to specify WWPN

63

Page 65: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

64© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Virtual Storage – Add Virtual Optical

• Media Repository has to be created as a pre-requisite• Use Edit Connections to specify/select server adapter id

64

Page 66: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

65© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Topology Diagrams

65

Page 67: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

66© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Export Network/Storage Topology Diagram

66

Page 68: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

67© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

System Virtual Networking Diagram

67

Page 69: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

68© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

System Virtual Storage Diagram

• Highlighted boxes show the mapping/paths

68

Page 70: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

69© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Partition Virtual Storage Diagram

69

Page 71: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

70© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Performance and Capacity Monitoring (PCM)

70

Page 72: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

71© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Performance and Capacity Monitoring (PCM)

• PCM available via REST API & GUI• To be enabled per system per HMC• User must have ManageUtilizationData task access to be able to change the PCM preference

settings• Long Term & Short Term Metrics

• Long Term – Collected every 30 seconds and purged after 30 minutes• Short Term – Collected every 5 seconds and purged after 30 minutes

• Raw, Processed & Aggregated Metrics• SSP PCM Metrics & Energy Metrics are available only via REST API

• Supported from HMC V8 R8.6.0 onwards• SSP Preference to be enabled individually apart from PCM enablement • Energy Metrics is supported on specific systems with FW 860.10 or later and gets

enabled if PCM is enabled on the system from the GUI or if Aggregation is enabled from the Rest API and can be enabled individually via the API as well.

• Rest API documentation at • https://www.ibm.com/support/knowledgecenter/P8ESS/p8ehl/concepts/PerformanceCapacityMonitor.htm

71

Page 73: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

72© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Performance and Capacity Monitoring (PCM)

• Raw Metrics :• Raw stats• Collected every 30 seconds for Long Term Monitoring (LTM)• Retained for 30 minutes

• Processed Metrics :• Works on Raw Metrics and performs series of computations to generate processed date• Generated every 30 seconds & only if aggregation is enabled• Retained for 2 hours

• Aggregated Metrics :• Works on Processed Metrics• Average, Minimum, Maximum of processed metric is maintained in the aggregated metric

• PCM graphs can be used to • Monitor to capacity (Over/Optimal/Under allocation)• Monitor to take pro-active measures by using the trends shown in the graphs

72

Page 74: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

73© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

PCM – Quick View

Enable/Disable PCM

Launch PCM Dashboard

Time stamp when data was collected

Virtual network traffic for server (doesn’t include dedicated IO assigned to lpars)

Virtual storage traffic for server

73

Page 75: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

74© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

PCM – Server Overview

Shows Over/Optimal/Under allocation for partitions based on entitled & utilized

74

Page 76: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

75© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

PCM – Server Overview

Shows Over/Optimal/Under allocation for partitions based on entitled & utilized

75

New in V8.860

Page 77: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

76© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

PCM – Processor Utilization

Allocated or Assigned to Partitions

76

Page 78: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

77© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

PCM – Memory Utilization

Allocated to Partitions, System Firmware Memory & Memory Pool

Allocated to dedicated memory Partitions +system firmware memory

77

Page 79: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

78© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

PCM – Storage Utilization

78

Page 80: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

79© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Console & Service Management

79

Page 81: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

80© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

HMC Management

• Menu Options which were under the HMC Management section in Classic View are listed under different options in Enhanced UI• Console Settings – Network settings, Locale, welcome text, date & time• Console Management – License, Update HMC, Backup/Restore, Save

Upgrade• User & Roles – Working with users, tasks/resource roles. • Systems & Console security – LDAP, Kerberos, Remote access• Serviceability – View Management Console events

80

Page 82: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

81© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

HMC Management

81

Page 83: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

82© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

HMC Management

82

Page 84: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

83© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

HMC Management

83

Page 85: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

84© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Service Management

84

Page 86: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

85© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

• http://www.ibm.com/training/events

• Blog Links :

• What's new in HMC V8 R8.6.0

• HMC V8 R8.6.0 Enhanced UI Updates

• Shared Storage Pool Management with HMC

• Creating Partition with Partition Templates in HMC

• Virtual Network Management with HMC Enhanced UI

• PowerVM Performance Monitoring – What's New In HMC R8 V8.6.0

• Related Sessions :

• p015010 – HMC Security & Auditing – Wednesday (24th May 2017) 4.30 – 5.30 PM – Sabal A

• p015007 – Power Systems Management Roadmap – Thursday (25th May 2017) 1.45 – 2.45 PM – Sabal D &

Monday (22nd May 2017) 3.15 – 4.15 PM – Sabal D

Session reference links

85

Page 87: HMC Enhanced UI Deep Dive - IBM · New design with easy access to social media and app links Developer Works Blogs on PowerVM –Available only when accessing HMC remotely User Credentials

86© Copyright IBM Corporation 2017. Technical University/Symposia materials may not be reproduced in whole or in

part without the prior written permission of IBM.© Copyright IBM Corporation 2017. Materials may not be reproduced in whole or in

part without the prior written permission of IBM.

Questions?

Share at https://www.ibm.com/developerworks/community/groups/community/po

werhmc

• Have questions about PowerVM (VIOS, HMC, NovaLink, Hypervisor) ?

• Want to follow what’s new?

• Want additional information about existing functions?

Join the PowerVM LinkedIn group https://www.linkedin.com/groups/8403988

86