ESCO Capacity Building Seminar Hitachi Energy Solution Dec 18th 2008 Hitachi , Ltd. Energy Solution Div. Kenichi Kuwabara, Department Manager

Transcript of Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO)...

Page 1: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

ESCO Capacity Building Seminar

Hitachi Energy Solution

Dec 18th 2008

Hitachi , Ltd.

Energy Solution Div.

Kenichi Kuwabara, Department Manager

Page 2: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

Content

Industrial Sector

1. ESCO Example in Thailand

2. ESCO Example in Philippine

3. ESCO Example in Singapore

4. ESCO Example for Shopping Center

5. ESCO Example for City Government Office

Commercial Sector

1

Page 3: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

1-1. Overview of customer

Country : Thailand

Production : Hard Disk Drive

Established : Feb , 1997

Production : Dec , 1997

2

Page 4: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

1-2. Example in Thailand (Before ESCO)

Through flow

Boilers

3

S : SteamD : Drain H : Hot waterCD : Cooling water

Dry air

Cleaning machines

Laundry ( Drying

Machine )

Steam Header

(50℃)HX

S

S

S

D

D

H

UDI water(30℃)

Air compressor

Cooling Tower

H

HX

P

CDCD

HLow temp

high temp

Focus-1OIL

Waste Energy

Compressor

Page 5: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

1-3. Example in Thailand (After ESCO)

Energy recovery from hot air of Air Compressor

4

Page 6: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

1-4. Project Schedule - ESCO in Thailand

ESCO Service started in April 2007

No ITEM

1 Energy recovery for ZR300After cooler -Order Delivery Comp #4 Shutdown 20days ,Comp #9 Shutdown 20days -Installation Total : 40days -Test & Commissioning

2 Hot water Piping work -Design -Material Order -Installation -Test & Commissioning

3 DI water -Modification DI Pipe

UDI Water Shutdown 12hr/each locationDate to be discussion

J anuary FebruarySeptember October November December

Test run Feb-Mar.

2006 2007

5

Page 7: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

1-5. Project Overview - Thailand Case

ESCO Project Opening Ceremony : Apr/03

Implement of heat recovery system for existing air Compressors Global remote monitoring system

6

Page 8: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

1-6. Effect of ESCO and Recognitions

Advantage : Energy saving, Cost saving, and CO2 emission reductionESCO realizes 11% of the energy saving

Jul 30, 2008, Thailand Energy Award granted by Lieutenant-General Poonpirom Liptapanlop, Minister of Energy, Thailand

May 13, 2008, the PEZA Outstanding Environmental Performer Award, granted by Executive Secretary Eduardo Ermita and Atty. Gen. Lilia de Lima

ESCO reduces 750 t-CO2 / yearAdvantage : Energy saving, Cost saving, and CO2 emission reduction

7

Page 9: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

Content

Industrial Sector

1. ESCO Example in Thailand

2. ESCO Example in Philippine

3. ESCO Example in Singapore

4. ESCO Example for Shopping Center

5. ESCO Example for City Government Office

Commercial Sector

8

Page 10: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

2-1. Overview of customer

Country : Philippine

Production : Magnetic recording head

Established : April , 1996

Energy Consumption Amount: Electricity 24,000 MWh : Oil 190,000 kL

9

Page 11: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

2-2. ESCO Approach - Philippines Case

ESCO Phase-1 : Feb. 2005 - Apr. 2006

Energy recovery from hot exhaust gas of power generators (Step-1)

Replace aged turbo chillers with new high efficient chillers (Step-1)

Energy recovery from hot water of power generators

ESCO Phase-2 : Sep. 2006 - May 2007

Energy recovery from hot exhaust gas of power generators (Step-2)

Replace aged turbo chillers with new high efficient chillers (Step-2)

Install closed chilled water system

10

Page 12: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

2-3. Power Generation Facilities(Before ESCO)

Focus-3

Generator(1500kW)

NO.1

・・・

Power network

FuelFuel

Heat-exchanger

Generator(1500kW)

NO.2

DeNOx

silencer

Cooling tower

Heat-exchangerCooling tower

Exhaust gas (285deg.C)

NO.8 Diesel engine

Dieselengines

Dieselengines

Focus-1

Focus-2

Focus-2Turbo chiller

200RT

7℃12℃

Turbo chiller200RT

7℃12℃

Turbo chiller200RT

7℃12℃

Turbo chiller300RT

Four aged chillers

HitachiTurbo chiller

380RT

HitachiTurbo chiller

380RT

HitachiTurbo chiller

380RT7℃

12℃ HitachiTurbo chiller

380RT7℃

12℃ HitachiTurbo chiller

380RT7℃

12℃

#7 #8 #9

7℃

12℃

#67℃

12℃

#5

11

Page 13: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

2-4. Final Configuration(After ESCO)

DeNOx Exhaust heat steam boiler

Hot water absorption chiller

350RT

85℃

80℃

Steam Absorption chiller

450RT

Through flow boiler

water supply

:Scope of ESCO(Phase2)

Diesel engines

silencer

NO.1, NO.2

DeNOx

Exhaust gas

Diesel engines

silencer

NO.3, NO.4

Exhaust heat steam boiler

Exhaust gas

7℃12℃7℃12℃< Phase1 >

< Phase1 >

< Phase1 >

< Phase1>

< Phase2>

Steam

Steam

NO.5,NO.6 Diesel engine

NO.7,NO.8 Diesel engine

Carrier chiller200RT

Carrier chiller200RT

Carrier chiller200RT

Back-up

Back-up

Back-up

Tube cleaning system

Tube cleaning system < Phase2> < Phase2>

< Phase1 >High efficiencyTurbo chiller

450RT7℃

12℃

7℃

12℃

7℃

12℃ HitachiTurbo chiller

380RT7℃

12℃ HitachiTurbo chiller

380RT7℃

12℃ HitachiTurbo chiller

380RT7℃

12℃High efficiencyTurbo chiller

450RT

High efficiencyTurbo chiller

450RT

< Phase2> < Phase2>

#7 #8 #9

Action-4

Action-4

Action-512

Page 14: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

ESCO

Monitoring

2006

311 19753 41 284 26 1 0

Turbo chiller

Hot water absorption chiller

Steam absorption chiller

Aged Turbo chiller Removal

Exhaust heat steam boilerHot water recovery

Design and Piping

2

2005

Hot water recovery pipe

Installation

Installation

Design exhaust and absorption chiller Common Pipe

Installation

Check energy consumption

Estimation Design Set up Monitor

CP

2-5. Project Schedule - ESCO Phase 1 in Philippines

13

Page 15: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

ESCO

2007

Chilled water system

Tube cleaning system

Turbo chiller Removal

Exhaust heat steam boiler

2006

Installation

Installation

Installation

Estimation Design Set up Monitor

CP

2-6. Project Schedule - ESCO Phase 2 in Philippines

311 19 41 2 21 0 5

Turbo chiller HC-F500GX #2Turbo chiller HC-F500GX #3

Installation

Design

Exhaust piping modification

Installation

Common pipingDesign

14

Page 16: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

2-7. Project Overview - Philippines Case

Modification of existing diesel engines to cogeneration systemAdoption of three high-efficiency centrifugal chillers and two typeGlobal remote monitoring system

JAPAN

Chilled waterExhaust gas

Power

( existing )

Fuel

Steam

Diesel engines Exhaust heat steam boiler

[2 units]

SteamAbsorption chiller

ESCO

Tube cleaning system

Hot water

Chilled water

Cooling water

Hot water Absorption chiller

Centrifugal chiller [3 units]

Chilled water

Power

Monitoring system

Chilled water

Tube cleaning system Centrifugal chiller

(existing)[3 units]

Chilled water

ESCO Opening Ceremony, April 20, 2006

15

Page 17: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

2-8. Media News - Philippines Case

Hitachi To Help Overseas Firms Conserve Energy2005/06/18, 03:07, Nikkei English News, 279 words

TOKYO (Nikkei)--Hitachi Ltd. (6501) is expanding its energy service company (ESCO), which helps firms cut electricity use at factories, to businesses abroad.

In ESCO operations, Hitachi examines a production site, sets up energy-saving equipment and then receives a service fee based on the resulting cost reductions.

Hitachi started the service at the Philippines hard-disk drive plant of its U.S. subsidiary. It plans to install a boiler that recovers heat from the factory's diesel engine generator and powers a freezer that cools electronic parts.

16

Page 18: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

Content

Industrial Sector

1. ESCO Example in Thailand

2. ESCO Example in Philippine

3. ESCO Example in Singapore

4. ESCO Example for Shopping Center

5. ESCO Example for City Government Office

Commercial Sector

17

Page 19: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

3-1. Overview of customer

Country : Singapore

Production : DRAM(Dynamic random access memory)

Established : July , 1996

Energy Consumption Amount: Electricity 160,000 GWh

18

Page 20: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

3-2. ESCO Example in Singapore

19

■ Series counter flow high efficiency for centri fugal chiller(2set)

This is the best method for wide range temperature system

■ Global remote monitoring system

OverviewOverview

MeteringSystem

JAPAN

MonitoringCenter

6℃10℃14℃

Lead Unit Lag Unit

■ Modification for Ball Cleaning System

2600RT : 2 set⇒ Total 5200RT

Hitachi Centrifugal Chiller:Series Counter Flow

Chilled Water-OutChilled Water-In

CO2 Reduction5,000ton/year

CO2 Reduction5,000ton/year

High Efficiency Centrifugal Chiller

Page 21: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

3-3. System flow (Before ESCO)

NORTH SIDE

SOUTH SIDE

C/R & INSPN RM

M

M

M

M

M

Before ESCO

Existing chillers (1,200USRT)10units

12℃

16℃

16℃

16℃ 6℃

6℃

6℃

6℃

(12.4℃)(12.4℃)

COP = 4.6 (Spec.)

20

Page 22: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

3-4. System flow (After ESCO)

NORTH SIDE

SOUTH SIDE

C/R & INSPN RM

M

M

M

M

M

After ESCO

New chiller

Existing chillers (1,200USRT) 6units

New chiller

New chiller New chiller

12℃

16℃

16℃

16℃ 6℃

6℃

6℃

6℃

(12.4℃)(12.4℃)

COP = 4.6 (Spec.) COP = 5.8 (Spec.)

21

Page 23: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

Content

Industrial Sector

1. ESCO Example in Thailand

2. ESCO Example in Philippine

3. ESCO Example in Singapore

4. ESCO Example for Shopping Center

5. ESCO Example for City Government Office

Commercial Sector

22

Page 24: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

4-1 Example for Shopping Center

Country Country :: JapanJapan

Customer Customer :: Shopping CenterShopping Center

Total Floor Space : 76,000m2Total Floor Space : 76,000m2

Installation Equipment Installation Equipment :: Gas Engine CoGas Engine Co--generation generation SystemSystem

(720kW(720kW--630RT : 3 630RT : 3 sets)sets)● Energy conservation and CO2 emissions reduction effect

Annual energy amount (KL) CO2 gas emissions (ton-CO2)Reduction amount 1,060 3,000

Reduction rate 13% 15%

23

Page 25: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

4-2 Example for Shopping Center

24

Electricity

Gas EngineAbsorption

He

Electricity

Gas EngineAbsorption

Exhaust gas

hot water

Cooling Water

Gas

Generator

Chilled Water

Cooling Tower

Cooling Tower

Chilled Water

Exhaust gas

Generator

Cooling Water

hot water

Gas

Electricity

Gas Eco-Pack system diagram

Page 26: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

Content

Industrial Sector

1. ESCO Example in Thailand

2. ESCO Example in Philippine

3. ESCO Example in Singapore

4. ESCO Example for Shopping Center

5. ESCO Example for City Government Office

Commercial Sector

25

Page 27: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

5-1 Example for City Government Office

Country Country :: JapanJapan

Number of floorsNumber of floors:: 8 above ground level8 above ground level2 under ground level2 under ground level

Total floor areaTotal floor area: 18,875 m: 18,875 m22

Contract demandContract demand: 680 kW: 680 kW

Air conditioning equipmentAir conditioning equipment::Absorption chillerAbsorption chillerAir cooled chillerAir cooled chiller

Guaranteed SavingsGuaranteed Savings3 years3 years’’ contract contract

26

Page 28: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

5-2 Example for City Government Office

Energy Conservation MeasuresEnergy Conservation Measures Energy Saving EffectEnergy Saving Effect

Introduction of highIntroduction of high--efficiencyefficiencyLighting equipment(2,053unit)Lighting equipment(2,053unit)

5.0%5.0%

Inverter Control on Inverter Control on Chilled water pump(3unit)Chilled water pump(3unit)and AHU(9unit)and AHU(9unit)

8.0%8.0%

Unutilized Energy GeneratorUnutilized Energy Generator 0.2%0.2%

TotalTotal 13.2%13.2%

27

Page 29: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

5-3 Example for City Government Office

Generator integrated type

in-line hydraulic turbine

Drain protective

valve

Storage tank(chilled and hot

water)

Pump for chilled/hot water supply

Water flow

P

Drain protectivevalve

AHUEnergy recovery

systemControl panel

To grid

Outletvalve

Pressure gauge

Inletvalve

Unused energy recovery system diagram

28

Page 30: Hitachi Energy Solution - Thai ESCO · 2019-12-18 · 2-3. Power Generation Facilities(Before ESCO) Focus-3 Generator (1500kW) ~ NO.1 ・・・ Power network FuFuelel Heat-exchanger

Hitachi Energy Solution

Dec 18th 2008

Hitachi , Ltd.

Energy Solution Div.

Kenichi Kuwabara, Department Manager