Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01....

42
Chema Diagnostica Via Campania 2/4 I-60030 Monsano | An Italy T +39 0731 605064 | F +39 0731 605672 www.chema.com | [email protected] Hitachi 717 instructions rev 408.0.2 - 2010-08-01

Transcript of Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01....

Page 1: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Chema DiagnosticaVia Campania 2/4I-60030 Monsano | An ItalyT +39 0731 605064 | F +39 0731 605672www.chema.com | [email protected]

Hitachi 717 instructionsrev 408.0.2 - 2010-08-01

Page 2: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions
Page 3: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 3 of 42

Warning!

These programs should be used only as guideline.

To check the reagent correct setting on the

instrument, use only good quality control sera

and work accordingly to with good laboratory

practice. Instrumental factor must be checked.

Chema Diagnostica will not be responsible for

instrumental bad programming.

Hitachi 717 instructionsrev 408.0.2 - 2010-08-01

Page 4: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 4 of 42

Application: ACIDPHOSPHATASE(TOTAL)- Codes AC 0120 TC Preparation: POWDER SINGLE REAGENT. FOLLOW PREPARATION PROGRAM IDICATED IN INSERT SHEET. INSTALL AS R1 Storage: REFRIGERATE AT 2-8°C

PROGRAM

TEST: ACP ASSAY CODE: RATE-A - 30 - 50 SAMPLE VOL: 20 R1 VOLUME: 230 R2 VOLUME: 0 WAVELENGHTS: 700 - 415 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 10000 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 0 - 5.1 PANIC VALUE: 0 - 75

X - X* user def

Page 5: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 5 of 42

Application: ACIDPHOSPHATASE(NONPROSTATIC)- Codes AC 0120 TC Preparation: POWDER SINGLE REAGENT. FOLLOW PREPARATION PROGRAM INDICATED IN INSERT SHEET. INSTALL AS R1 Storage: REFRIGERATE AT 2-8°C

PROGRAM

TEST: ACP ASSAY CODE: RATE-A - 30 - 50 SAMPLE VOL: 20 R1 VOLUME: 230 R2 VOLUME: 0 WAVELENGHTS: 700 - 415 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 10000 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 0 - 4.1 PANIC VALUE: 0 - 75

X - X* user def

Page 6: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 6 of 42

Application: ALBUMIN- Codes BC 0100 / 0500 / 1000 / 1500 CH Preparation: R1 - LIQUID READY TO USE SINGLE REAGENT Storage: ROOM TEMPERATURE OR REFRIGERATE (2-30°C) Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: ALB ASSAY CODE: 1POINT - 50 - 0 SAMPLE VOL: 3 R1 VOLUME: 250 R2 VOLUME: 0 WAVELENGHTS: 700 - 600 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 3.8 - 5.1 PANIC VALUE: 1.0 - 7.0

X - X* user def

Page 7: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 7 of 42

Application: ALKALINEPHOSPHATASEDGKCFL - Codes AL F080 / F245 / F400 / F600 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT A R2 - INSTALL LIQUID READY TO USE REAGENT B Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: ALP ASSAY CODE: RATE-A - 35 - 48 SAMPLE VOL: 4 R1 VOLUME: 200 R2 VOLUME: 50 WAVELENGHTS: 660 - 415 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 10000 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 64 - 306 PANIC VALUE: 5 - 2000

X - X* user def

Page 8: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 8 of 42

Application: ALKALINEPHOSPHATASEIFCCFL - Codes AF F080 / F245 / F400 / F600 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT A R2 - INSTALL LIQUID READY TO USE REAGENT B Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: ALP ASSAY CODE: RATE-A - 35 - 48 SAMPLE VOL: 4 R1 VOLUME: 200 R2 VOLUME: 50 WAVELENGHTS: 660 - 415 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 10000 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 28 - 100 PANIC VALUE: 5 - 2000

X - X* user def

Page 9: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 9 of 42

Application: AMYLASEFL - Codes AM F060 / F120 / F245 CH Preparation: R1 -LIQUID READY TO USE SINGLE REAGENT Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: AMY ASSAY CODE: RATE-A - 06 - 20 SAMPLE VOL: 10 R1 VOLUME: 250 R2 VOLUME: 0 WAVELENGHTS: 660 - 415 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 10000 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 0 - 96 (*) PANIC VALUE: 2 - 1800 (*)

X - X* useer def

NOTE: CNP-G3 method is not always available among calibrator values. If it fails, use PNP-G7 value or EPS, and program the parameters (*) as indicated below:

EXPECTED VALUE: 10 - 220 PANIC VALUE: 2 - 5000

Page 10: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 10 of 4210 of 4242

Application: AMYLASEEPSFL - Codes EA F080 / F245 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT A R2 - INSTALL LIQUID READY TO USE REAGENT B Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: AMY ASSAY CODE: RATE-A - 32 - 48 SAMPLE VOL: 7 R1 VOLUME: 200 R2 VOLUME: 50 WAVELENGHTS: 660 - 415 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 10000 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 10 - 220 PANIC VALUE: 2 - 5000

X - X* useer def

Page 11: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 11 of 4211 of 4242

Applicatione: PANCREATICISOAMYLASEFL - Code PA F080 / F245 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT A R2 - INSTALL LIQUID READY TO USE REAGENT B Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: AMYP ASSAY CODE: RATE-A - 32 - 48 SAMPLE VOL: 7 R1 VOLUME: 200 R2 VOLUME: 50 WAVELENGHTS: 660 - 415 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 10000 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 17 - 115 PANIC VALUE: 2 - 5000

X - X* user def

Page 12: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 12 of 4212 of 4242

Application: BICARBONATEFL - Codes BR F060 / F245 / F400 CH Preparation: R1 - LIQUID READY TO USE SINGLE REAGENT Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: C02 ASSAY CODE: 1POINT - 20 - 0 SAMPLE VOL: 3 R1 VOLUME: 300 R2 VOLUME: 0 WAVELENGHTS: 700 - 415 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - DEC PROZONE LIMIT: 0 EXPECTED VALUE: 22 - 29 PANIC VALUE: 2 - 50

X - X* user def

Page 13: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 13 of 4213 of 4242

Application: BILIRUBINTOTALFL - Code DT F125 / F500 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT A R2 - INSTALL LIQUID READY TO USE REAGENT B Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: BILT ASSAY CODE: 2POINT - 20 - 50 SAMPLE VOL: 15 R1 VOLUME: 240 R2 VOLUME: 60 WAVELENGHTS: 700 - 505 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 0.1 - 1.2 PANIC VALUE: 0.0 - 20.0

X - X* user def

Page 14: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 14 of 4214 of 4242

Application: BILIRUBINDIRECTFL - Code DD F125 / F500 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT A R2 - INSTALL LIQUID READY TO USE REAGENT B Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: BILD ASSAY CODE: 2POINT - 20 - 50 SAMPLE VOL: 15 R1 VOLUME: 240 R2 VOLUME: 60 WAVELENGHTS: 700 - 546 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 0.0 - 0.2 PANIC VALUE: 0.0 - 20.0

X - X* user def

Page 15: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 15 of 4215 of 4242

Application: CALCIUM- Code CA 0305 / 0505 CH Preparation: R1 -INSTALL LIQUID READY TO USE REAGENT B R2 -INSTALL LIQUID READY TO USE REAGENT A Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: CA ASSAY CODE: 1POINT - 50 - 0 SAMPLE VOL: 3 R1 VOLUME: 125 R2 VOLUME: 125 WAVELENGHTS: 700 - 570 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 9.2 - 11.0 PANIC VALUE: 3.0 - 20.0

X - X* user def

Page 16: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 16 of 4216 of 4242

Application: CALCIUMASX - Code CA 0100 / 0500 CH Preparation: R1 - LIQUID READY TO USE SINGLE REAGENT Storage: ROOM TEMPERATURE OR REFRIGERATE (2-30°C) Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: CA ASSAY CODE: 1POINT - 50 - 0 SAMPLE VOL: 3 R1 VOLUME: 250 R2 VOLUME: 0 WAVELENGHTS: 700 - 660 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 9.2 - 11.0 PANIC VALUE: 3.0 - 20.0

X - X* user def

Page 17: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 17 of 4217 of 4242

Application: CHOLESTEROLFL - Code CT F100 / F400 / 100F / 150F CH Preparation: R1 - LIQUID READY TO USE SINGLE REAGENT Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: CHOL ASSAY CODE: 1POINT - 50 - 0 SAMPLE VOL: 3 R1 VOLUME: 250 R2 VOLUME: 0 WAVELENGHTS: 700 - 505 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 140 - 200 PANIC VALUE: 70 - 750

X - X* user def

Page 18: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 18 of 4218 of 4242

Application: HDLDIRECTFL- Code HD F080 / F245 / F400 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT A R2 - INSTALL LIQUID READY TO USE REAGENT B CALIBRATOR - RECONSTITUTE AS INDICATED IN INSERT SHEET Storage: REFRIGERATE AT 2-8°C Stability: 60 DAYS OPEN BOTTLES - CALIBRATOR: AS INDICATED IN INSERT SHEET

PROGRAM

TEST: HDL ASSAY CODE: 2POINT - 20 - 50 SAMPLE VOL: 3 R1 VOLUME: 252 R2 VOLUME: 84 WAVELENGHTS: 700 - 600 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 35 - 55 PANIC VALUE: 10 - 180

X - X* user def

Page 19: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 19 of 4219 of 4242

Application: LDLDIRECTFL- Code DL F080 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT A R2 - INSTALL LIQUID READY TO USE REAGENT B CALIBRATOR - RECONSTITUTE AS INDICATED IN INSERT SHEET Storage: REFRIGERATE AT 2-8°C Stability: 60 DAYS OPEN BOTTLES - CALIBRATOR: AS INDICATED IN INSERT SHEET

PROGRAM

TEST: LDL ASSAY CODE: 2POINT - 20 - 50 SAMPLE VOL: 3 R1 VOLUME: 252 R2 VOLUME: 84 WAVELENGHTS: 700 - 600 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 76 - 218 PANIC VALUE: 10 - 400

X - X* user def

Page 20: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 20 of 4220 of 4242

Application: CHOLINESTERASEFL(DGKC)- Codes CH F096 / F245 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT A R2 - INSTALL LIQUID READY TO USE REAGENT B Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: CHE ASSAY CODE: RATE-A - 28 - 32 SAMPLE VOL: 6 R1 VOLUME: 200 R2 VOLUME: 40 WAVELENGHTS: 660 - 415 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 12000 - DEC PROZONE LIMIT: 0 EXPECTED VALUE: 5600 - 11200 PANIC VALUE: 1000 - 25000

X - X* user def

Page 21: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 21 of 4221 of 4242

Application: CK-NACFL - Codes CK F060 / F120 / F245 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT A R2 - INSTALL LIQUID READY TO USE REAGENT B Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: CK ASSAY CODE: RATE-A - 36 - 48 SAMPLE VOL: 8 R1 VOLUME: 200 R2 VOLUME: 50 WAVELENGHTS: 376 - 340 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 10000 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 0 - 190 PANIC VALUE: 2 - 2500

X - X* user def

Page 22: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 22 of 4222 of 4242

Application: CK-MBFL - Code MB F060 / F120 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT A R2 - INSTALL LIQUID READY TO USE REAGENT B Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: CKMB ASSAY CODE: RATE-A - 36 - 48 SAMPLE VOL: 10 R1 VOLUME: 200 R2 VOLUME: 50 WAVELENGHTS: 376 - 340 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 10000 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 0 - 24 PANIC VALUE: 2 - 2000

X - X* user def

Page 23: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 23 of 4223 of 4242

Application: COPPER- Code CU 0100 CH Preparation: R1 - MIX REAGENT A + REAGENT B AS INDICATED IN INSERT SHEET Storage: DO NOT REFRIGERATE! Stability: 2 WEEKS

PROGRAM

TEST: CU ASSAY CODE: 1POINT - 50 - 0 SAMPLE VOL: 12 R1 VOLUME: 250 R2 VOLUME: 0 WAVELENGHTS: 700 - 570 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 80 - 140 PANIC VALUE: 3 - 500

X - X* user def

Page 24: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 24 of 4224 of 4242

Application: CREATININE- Code CR 0500 / 1000 / 1500 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT B R2 - INSTALL LIQUID READY TO USE REAGENT A Storage: ROOM TEMPERATURE OR REFRIGERATE (2-30°C) Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: CREA ASSAY CODE: 2POINT - 28 - 32 SAMPLE VOL: 10 R1 VOLUME: 125 R2 VOLUME: 125 WAVELENGHTS: 700 - 505 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 0.6 - 1.2 PANIC VALUE: 0.2 - 12.0

X - X* user def

Page 25: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 25 of 4225 of 4242

Application: GAMMA-GTFL - Codes GT F080 / F245 / F400 / F600 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT A R2 - INSTALL LIQUID READY TO USE REAGENT B Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: GGT ASSAY CODE: RATE-A - 35 - 48 SAMPLE VOL: 20 R1 VOLUME: 200 R2 VOLUME: 50 WAVELENGHTS: 660 - 415 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 10000 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 11 - 50 PANIC VALUE: 1 - 1000

X - X* user def

Page 26: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 26 of 4226 of 4242

Application: GLUCOSEFL - Code GL F400 / 100F / 150F CH Preparation: R1 - LIQUID READY TO USE SINGLE REAGENT Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: GLUC ASSAY CODE: 1POINT - 50 - 0 SAMPLE VOL: 3 R1 VOLUME: 250 R2 VOLUME: 0 WAVELENGHTS: 700 - 505 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 70 - 110 PANIC VALUE: 20 - 450

X - X* user def

Page 27: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 27 of 4227 of 4242

Application: GLUCOSEUVFL - Code GL F601 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT A R2 - INSTALL LIQUID READY TO USE REAGENT B Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: GLUC ASSAY CODE: 1POINT - 50 - 0 SAMPLE VOL: 3 R1 VOLUME: 250 R2 VOLUME: 0 WAVELENGHTS: 376 - 340 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 60 - 110 PANIC VALUE: 20 - 800

X - X* user def

Page 28: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 28 of 4228 of 4242

Application: GOT/ASTFL - Codes GO F080 / F245 / F400 / F600 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT A R2 - INSTALL LIQUID READY TO USE REAGENT B Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: GOT ASSAY CODE: RATE-A - 36 - 48 SAMPLE VOL: 20 R1 VOLUME: 200 R2 VOLUME: 50 WAVELENGHTS: 376 - 340 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 10000 - DEC PROZONE LIMIT: 0 EXPECTED VALUE: 5 - 40 PANIC VALUE: 1 - 700

X - X* use def

Page 29: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 29 of 4229 of 4242

Application: GPT/ALTFL - Codes GP F080 / F245 / F400 / F600 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT A R2 - INSTALL LIQUID READY TO USE REAGENT B Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: GPT ASSAY CODE: RATE-A - 36 - 48 SAMPLE VOL: 20 R1 VOLUME: 200 R2 VOLUME: 50 WAVELENGHTS: 376 - 340 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 10000 - DEC PROZONE LIMIT: 0 EXPECTED VALUE: 5 - 40 PANIC VALUE: 1 - 700

X - X* user def

Page 30: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 30 of 4230 of 4242

Application: IRONFZ - Codes FE F245 / F400 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT A R2 - INSTALL REAGENT B (READ PREPARATION IN MANUAL INSERT SHEET) Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: FE ASSAY CODE: 2POINT - 20 - 50 SAMPLE VOL: 20 R1 VOLUME: 240 R2 VOLUME: 60 WAVELENGHTS: 700 - 570 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 59 - 158 PANIC VALUE: 10 - 700

X - X* user def

Page 31: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 31 of 4231 of 4242

Application: LDHFL - Codes LD F060 / F120 / F245 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT A R2 - INSTALL LIQUID READY TO USE REAGENT B Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: LIP ASSAY CODE: RATE-A - 35 - 48 SAMPLE VOL: 3 R1 VOLUME: 200 R2 VOLUME: 50 WAVELENGHTS: 700 - 570 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 10000 - DEC PROZONE LIMIT: 0 EXPECTED VALUE: 0 - 60 PANIC VALUE: 1 - 300

X - X* user def

Page 32: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 32 of 4232 of 4242

Application: LIPASEFL - Codes LP F060 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT A R2 - INSTALL LIQUID READY TO USE REAGENT B Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: LIP ASSAY CODE: RATE-A - 35 - 48 SAMPLE VOL: 4 R1 VOLUME: 200 R2 VOLUME: 50 WAVELENGHTS: 376 - 340 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 10000 - DEC PROZONE LIMIT: 0 EXPECTED VALUE: 225 - 450 PANIC VALUE: 20 - 4000

X - X* user def

Page 33: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 33 of 4233 of 4242

Application: MAGNESIUM- Code MG 0200 / 0500 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT B R2 - INSTALL LIQUID READY TO USE REAGENT A Storage: ROOM TEMPERATURE OR REFRIGERATE (2-30°C) Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: MG ASSAY CODE: 1POINT - 50 - 0 SAMPLE VOL: 3 R1 VOLUME: 125 R2 VOLUME: 125 WAVELENGHTS: 700 - 505 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 1.3 - 2.1 PANIC VALUE: 0.5 - 8.5

X - X* user def

Page 34: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 34 of 4234 of 4242

Application: MAGNESIUMXL- Code MX 0300 / 0500 CH Preparation: R1 - LIQUID READY TO USE SINGLE REAGENT Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: MG ASSAY CODE: 1POINT - 50 - 0 SAMPLE VOL: 3 R1 VOLUME: 300 R2 VOLUME: 0 WAVELENGHTS: 700 - 546 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 1.3 - 2.1 PANIC VALUE: 0.5 - 6.0

X - X* user def

Page 35: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 35 of 4235 of 4242

Application: PHOSPHORUS- Code PH 0100 / 0500 CH Preparation: R1 - LIQUID READY TO USE SINGLE REAGENT Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: PHOS ASSAY CODE: 1POINT - 50 - 0 SAMPLE VOL: 3 R1 VOLUME: 250 R2 VOLUME: 0 WAVELENGHTS: 376 - 340 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 2.3 - 4.7 PANIC VALUE: 0.5 - 15.0

X - X* user def

Page 36: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 36 of 4236 of 4242

Application: PROTEINSHS- Code HS 0100 / 0500 CH Preparation: R1 - LIQUID READY TO USE SINGLE REAGENT Storage: ROOM TEMPERATURE OR REFRIGERATE (2-30°C) Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: HS ASSAY CODE: 1POINT - 50 - 0 SAMPLE VOL: 10 R1 VOLUME: 300 R2 VOLUME: 0 WAVELENGHTS: 700 - 600 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 28 - 141 PANIC VALUE: 3 - 500

X - X* user def

Page 37: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 37 of 4237 of 4242

Application: TOTALPROTEINS- Codes TP 0500 / 1000 / 1500 CH Preparation: R1 - LIQUID READY TO USE SINGLE REAGENT Storage: ROOM TEMPERATURE OR REFRIGERATE (2-30°C) Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: TP ASSAY CODE: 1POINT - 50 - 0 SAMPLE VOL: 3 R1 VOLUME: 250 R2 VOLUME: 0 WAVELENGHTS: 700 - 546 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 6.0 - 7.8 PANIC VALUE: 3.0 - 12.0

X - X* user def

Page 38: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 38 of 4238 of 4242

Application: TRIGLYCERIDESFL - Codes TR F100 / F400 / 100F / 150F CH Preparation: R1 - LIQUID READY TO USE SINGLE REAGENT Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: TRIG ASSAY CODE: 1POINT - 50 - 0 SAMPLE VOL: 3 R1 VOLUME: 250 R2 VOLUME: 0 WAVELENGHTS: 700 - 505 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 10 - 190 PANIC VALUE: 5 - 1000

X - X* user def

Page 39: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 39 of 4239 of 4242

Application: UREAUVFL - Codes AZ F080 / F245 / F400 / F600 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT A R2 - INSTALL LIQUID READY TO USE REAGENT B Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: UREA ASSAY CODE: 2POINT - 32 - 36 SAMPLE VOL: 3 R1 VOLUME: 200 R2 VOLUME: 50 WAVELENGHTS: 376 - 340 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - DEC PROZONE LIMIT: 0 EXPECTED VALUE: 10 - 50 PANIC VALUE: 2 - 250

X - X* user def

Page 40: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 40 of 4240 of 4242

Application: URICACIDTFL - Code AU F402 CH Preparation: R1 - MIX REAGENT A + REAGENT B AS INDICATED IN INSERT SHEET Storage: REFRIGERATE AT 2-8°C Stability: 90 DAYS

PROGRAM

TEST: UA ASSAY CODE: 1POINT - 50 - 0 SAMPLE VOL: 5 R1 VOLUME: 250 R2 VOLUME: 0 WAVELENGHTS: 700 - 546 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 3.5 - 7.7 PANIC VALUE: 1.0 - 20.0

X - X* user def

Page 41: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 41 of 4241 of 4242

Application: URICACIDAOXFL - Code AX F100 / F250 / F600 CH Preparation: R1 - INSTALL LIQUID READY TO USE REAGENT A R2 - INSTALL LIQUID READY TO USE REAGENT B Storage: REFRIGERATE AT 2-8°C Stability: AS INDICATED IN THE LABEL

PROGRAM

TEST: UA ASSAY CODE: 2POINT - 20 - 50 SAMPLE VOL: 12 R1 VOLUME: 240 R2 VOLUME: 60 WAVELENGHTS: 700 - 546 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 3.5 - 7.2 PANIC VALUE: 0.0 - 35.0

X - X* user def

Page 42: Hitachi 717 instructions - Chema 717.pdf · Hitachi 717 instructions rev 408.0.2 - 2010-08-01. Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717 IUS.408.0.2 Directions

Analyzer: Hitachi717

Chema Diagnostica - Guidelines for automatic analyzers - Hitachi 717

IUS.408.0.2 Directions for use Edition 2010-08-01 page 42 of 4242 of 4242

Application: ZINC - Code ZN 0125 CH Preparation: R1 - MIX REAGENT A + REAGENT B AS INDICATED IN INSERT SHEET Storage: REFRIGERATE AT 2-8°C Stability: 2 WEEKS

PROGRAM

TEST: ZN ASSAY CODE: 1POINT - 50 - 0 SAMPLE VOL: 12 R1 VOLUME: 250 R2 VOLUME: 0 WAVELENGHTS: 700 - 570 CALIB METHOD: 1 - 0 STD 1 CONC. POS.: X - X* STD 2 CONC. POS.: 0 - 0 STD 3 CONC. POS.: 0 - 0 STD 4 CONC. POS.: 0 - 0 STD 5 CONC. POS.: 0 - 0 STD 6 CONC. POS.: 0 - 0 SD LIMIT: 0.250 DUPLICATE LIMIT: 100 SENSITIVITY LIMIT: 0 ABS LIMIT: 0 - INC PROZONE LIMIT: 0 EXPECTED VALUE: 70 - 115 PANIC VALUE: 3 - 500

X - X* user def