HILTON NEW YORK DOWNTOWN C01 - PSAV · 2020-02-10 · psav ® presentation services 2888 galvin...
Transcript of HILTON NEW YORK DOWNTOWN C01 - PSAV · 2020-02-10 · psav ® presentation services 2888 galvin...
This drawing is propreitary information intended for representation of concepts and for discussion purposes only for the intended recipient. This is not submitted as an exact plan and is intended to bus used as a guide to the approximate room setup at this facility. Since on-site variations or adjustments may occur, PSAV is not responsible for any unauthorized use of this document
PSAV ® Presentation Services2888 Galvin Parkway
Elgin, IL
RIGGINGSERVICES C01
HILTON NEW YORK DOWNTOWNGRAND BALLROOM SUITE
HILTON NEW YORK MIDTOWN1335 AVENUE OF THE AMERICAS
NEW YORK, NY. 10019
SHEET INDEXC-01 COVER PAGERCP-1 GRAND BALLROOM SUITERCP-2 BALLROOM DIMENSIONSRCP-3 RIGGING POINTSRCP-4 RIGGING POINTS DIMENSIONSRCP-5 BALLROOM STAGE RIGGING
LOCATIONSRCP-6 BALLROOM RIGHT ISOMETRIC
SHEET#
DATE:DRAWN BY:Lars E. Stevens
HIL
TON
NEW
YO
RK
MID
TOW
N13
35 A
VEN
UE
OF
THE
AM
ERIC
AS
NEW
YO
RK
, NY.
100
19
APPROVED BY:Demian Purdy
# OF TOTAL POINTS46
# OF EXISTING POINTS:46
CHANDALIERHEIGHT:N/A
AIRWALL HEIGHT:N/A
SQ. FOOTAGE: TILE HEIGHT:N/A
CEILING HEIGHT: SOFFIT HEIGHT:N/AN/A
19,200
This drawing is propreitary information intended for representation of concepts and for discussion purposes only for the intended recipient. This is not submitted as an exact plan and is intended to bus used as a guide to the approximate room setup at this facility. Since on-site variations or adjustments may occur, PSAV is not responsible for any unauthorized use of this document
01 October 2010
RCP1RIGGINGSERVICES
DATE:REVISED BY:Lars E. Stevens 22 May 2013GRAND BALLROOM SUITE
Scale: 1/8" = 1'-0"
PSAV ® Presentation ServicesRigging Services
2888 Galvin ParkwayElgin, IL
CLIENTS ARE RESPONSIBLE FOR DISCLOSING ALL
RIGGED ITEMS REGARDLESS OF WEIGHT. POINT LOAD CALCULATIONS WILL BE VERIFIED PRIOR
TO LOAD-IN. UNDISCLOSED ITEMS MAY RESULT IN ADDITIONAL POINT CHARGES AND DELAYS IN SET-UP.
NOTHING IS TO BE HUNG FROM THE AIRWALL TRACKS.
PSAV RIGGING SERVICES WILL APPROVE ALL RIGGING LOADS PRIOR TO LOAD-IN DATE.
ALL HOISTS AND CONTROL WILL BE PROV BY PSAV. ALL RIGGING HARDWARE MUST MEET ANSI
STANDARDS & DISPLAY BATCH LOT IDENTIFICATION.
STAGE
HYDRAULIC LIFT
HYDRAULIC LIFTUP
BALCONY
BALCONY BALCONY
UP
0 10 20 30 40 FT
SHEET#
DATE:DRAWN BY:Lars E. Stevens
HIL
TON
NEW
YO
RK
MID
TOW
N13
35 A
VEN
UE
OF
THE
AM
ERIC
AS
NEW
YO
RK
, NY.
100
19
APPROVED BY:Demian Purdy
# OF TOTAL POINTS46
# OF EXISTING POINTS:46
CHANDALIERHEIGHT:N/A
AIRWALL HEIGHT:N/A
SQ. FOOTAGE: TILE HEIGHT:N/A
CEILING HEIGHT: SOFFIT HEIGHT:N/AN/A
19,200
This drawing is propreitary information intended for representation of concepts and for discussion purposes only for the intended recipient. This is not submitted as an exact plan and is intended to bus used as a guide to the approximate room setup at this facility. Since on-site variations or adjustments may occur, PSAV is not responsible for any unauthorized use of this document
01 October 2010
RCP2RIGGINGSERVICES
DATE:REVISED BY:Lars E. Stevens 22 May 2013GRAND BALLROOM SUITE: DIMENSIONS
Scale: 1/8" = 1'-0"
PSAV ® Presentation ServicesRigging Services
2888 Galvin ParkwayElgin, IL
CLIENTS ARE RESPONSIBLE FOR DISCLOSING ALL
RIGGED ITEMS REGARDLESS OF WEIGHT. POINT LOAD CALCULATIONS WILL BE VERIFIED PRIOR
TO LOAD-IN. UNDISCLOSED ITEMS MAY RESULT IN ADDITIONAL POINT CHARGES AND DELAYS IN SET-UP.
NOTHING IS TO BE HUNG FROM THE AIRWALL TRACKS.
PSAV RIGGING SERVICES WILL APPROVE ALL RIGGING LOADS PRIOR TO LOAD-IN DATE.
ALL HOISTS AND CONTROL WILL BE PROV BY PSAV. ALL RIGGING HARDWARE MUST MEET ANSI
STANDARDS & DISPLAY BATCH LOT IDENTIFICATION.
STAGE
HYDRAULIC LIFT
HYDRAULIC LIFTUP
BALCONY
BALCONY BALCONY
UP
0 10 20 30 40 FT
48'-9 3/4"
78'-4 1/4"
49'-3
7/8
"
139'-6 1/8"
137'
-3 7
/8"
SHEET#
DATE:DRAWN BY:Lars E. Stevens
HIL
TON
NEW
YO
RK
MID
TOW
N13
35 A
VEN
UE
OF
THE
AM
ERIC
AS
NEW
YO
RK
, NY.
100
19
APPROVED BY:Demian Purdy
# OF TOTAL POINTS46
# OF EXISTING POINTS:46
CHANDALIERHEIGHT:N/A
AIRWALL HEIGHT:N/A
SQ. FOOTAGE: TILE HEIGHT:N/A
CEILING HEIGHT: SOFFIT HEIGHT:N/AN/A
19,200
This drawing is propreitary information intended for representation of concepts and for discussion purposes only for the intended recipient. This is not submitted as an exact plan and is intended to bus used as a guide to the approximate room setup at this facility. Since on-site variations or adjustments may occur, PSAV is not responsible for any unauthorized use of this document
01 October 2010
RCP3RIGGINGSERVICES
DATE:REVISED BY:Lars E. Stevens 22 May 2013GRAND BALLROOM SUITE: RIGGING POINTS
Scale: 1/8" = 1'-0"
PSAV ® Presentation ServicesRigging Services
2888 Galvin ParkwayElgin, IL
CLIENTS ARE RESPONSIBLE FOR DISCLOSING ALL
RIGGED ITEMS REGARDLESS OF WEIGHT. POINT LOAD CALCULATIONS WILL BE VERIFIED PRIOR
TO LOAD-IN. UNDISCLOSED ITEMS MAY RESULT IN ADDITIONAL POINT CHARGES AND DELAYS IN SET-UP.
NOTHING IS TO BE HUNG FROM THE AIRWALL TRACKS.
PSAV RIGGING SERVICES WILL APPROVE ALL RIGGING LOADS PRIOR TO LOAD-IN DATE.
ALL HOISTS AND CONTROL WILL BE PROV BY PSAV. ALL RIGGING HARDWARE MUST MEET ANSI
STANDARDS & DISPLAY BATCH LOT IDENTIFICATION.
STAGE
HYDRAULIC LIFT
HYDRAULIC LIFTUP
BALCONY
BALCONY BALCONY
UP
0 10 20 30 40 FT
SHEET#
DATE:DRAWN BY:Lars E. Stevens
HIL
TON
NEW
YO
RK
MID
TOW
N13
35 A
VEN
UE
OF
THE
AM
ERIC
AS
NEW
YO
RK
, NY.
100
19
APPROVED BY:Demian Purdy
# OF TOTAL POINTS46
# OF EXISTING POINTS:46
CHANDALIERHEIGHT:N/A
AIRWALL HEIGHT:N/A
SQ. FOOTAGE: TILE HEIGHT:N/A
CEILING HEIGHT: SOFFIT HEIGHT:N/AN/A
19,200
This drawing is propreitary information intended for representation of concepts and for discussion purposes only for the intended recipient. This is not submitted as an exact plan and is intended to bus used as a guide to the approximate room setup at this facility. Since on-site variations or adjustments may occur, PSAV is not responsible for any unauthorized use of this document
01 October 2010
RCP4RIGGINGSERVICES
DATE:REVISED BY:Lars E. Stevens 22 May 2013GRAND BALLROOM SUITE: RIGGING POINT DIMENSIONS
Scale: 1/8" = 1'-0"
PSAV ® Presentation ServicesRigging Services
2888 Galvin ParkwayElgin, IL
CLIENTS ARE RESPONSIBLE FOR DISCLOSING ALL
RIGGED ITEMS REGARDLESS OF WEIGHT. POINT LOAD CALCULATIONS WILL BE VERIFIED PRIOR
TO LOAD-IN. UNDISCLOSED ITEMS MAY RESULT IN ADDITIONAL POINT CHARGES AND DELAYS IN SET-UP.
NOTHING IS TO BE HUNG FROM THE AIRWALL TRACKS.
PSAV RIGGING SERVICES WILL APPROVE ALL RIGGING LOADS PRIOR TO LOAD-IN DATE.
ALL HOISTS AND CONTROL WILL BE PROV BY PSAV. ALL RIGGING HARDWARE MUST MEET ANSI
STANDARDS & DISPLAY BATCH LOT IDENTIFICATION.
STAGE
HYDRAULIC LIFT
HYDRAULIC LIFTUP
BALCONY
BALCONY BALCONY
UP
0 10 20 30 40 FT
206'-11 5/8"
48'-9 3/4"
78'-4 1/4"
49'-3
7/8
"
139'-6 1/8"
87'-8
"
137'
-3 7
/8"
27'-6 5/8" 26'-1" 28'-9" 12'-8 1/8" 7'-3 1/2" 7'-5 7/8" 12'-6 3/8" 29'-0 5/8" 24'-2 1/4" 31'-4 1/8"
20'-0 5/8" 19'-11 3/8"
12'-8 1/8" 14'-9 1/2" 12'-6 3/8"
3'-9
1/4
"
10'-5
1/4
"16
'-3"
27'-1
0 7/
8"18
'-2 3
/8"
14'-1
0 3/
8"
11'-9 1/8" 16'-0 1/8"
2'-2
3/8
"
SHEET#
DATE:DRAWN BY:Lars E. Stevens
HIL
TON
NEW
YO
RK
MID
TOW
N13
35 A
VEN
UE
OF
THE
AM
ERIC
AS
NEW
YO
RK
, NY.
100
19
APPROVED BY:Demian Purdy
# OF TOTAL POINTS46
# OF EXISTING POINTS:46
CHANDALIERHEIGHT:N/A
AIRWALL HEIGHT:N/A
SQ. FOOTAGE: TILE HEIGHT:N/A
CEILING HEIGHT: SOFFIT HEIGHT:N/AN/A
19,200
This drawing is propreitary information intended for representation of concepts and for discussion purposes only for the intended recipient. This is not submitted as an exact plan and is intended to bus used as a guide to the approximate room setup at this facility. Since on-site variations or adjustments may occur, PSAV is not responsible for any unauthorized use of this document
01 October 2010
RCP5RIGGINGSERVICES
DATE:REVISED BY:Lars E. Stevens 22 May 2013GRAND BALLROOM SUITE: STAGE RIGGING POINT DIMENSIONS
Scale: 3/8" = 1'-0"
PSAV ® Presentation ServicesRigging Services
2888 Galvin ParkwayElgin, IL
CLIENTS ARE RESPONSIBLE FOR DISCLOSING ALL
RIGGED ITEMS REGARDLESS OF WEIGHT. POINT LOAD CALCULATIONS WILL BE VERIFIED PRIOR
TO LOAD-IN. UNDISCLOSED ITEMS MAY RESULT IN ADDITIONAL POINT CHARGES AND DELAYS IN SET-UP.
NOTHING IS TO BE HUNG FROM THE AIRWALL TRACKS.
PSAV RIGGING SERVICES WILL APPROVE ALL RIGGING LOADS PRIOR TO LOAD-IN DATE.
ALL HOISTS AND CONTROL WILL BE PROV BY PSAV. ALL RIGGING HARDWARE MUST MEET ANSI
STANDARDS & DISPLAY BATCH LOT IDENTIFICATION.
STAGE
HYDRAULIC LIFT
HYDRAULIC LIFT
0 5 10 15 20 FT
48'-9 3/4"
7'-0 1/4" 11'-9 5/8" 12'-3 1/2" 9'-6" 8'-2 3/8"
7'-1
0"4'
-0"
5'-0
3/8
"8'
-0"
15'-2
5/8
"
25'-1
1 3/
8"
5'-5 5/8" 7'-0 5/8"
12'-8 1/4" 7'-3 1/2" 7'-6" 12'-6 3/8"
SHEET#
DATE:DRAWN BY:Lars E. Stevens
HIL
TON
NEW
YO
RK
MID
TOW
N13
35 A
VEN
UE
OF
THE
AM
ERIC
AS
NEW
YO
RK
, NY.
100
19
APPROVED BY:Demian Purdy
# OF TOTAL POINTS46
# OF EXISTING POINTS:46
CHANDALIERHEIGHT:N/A
AIRWALL HEIGHT:N/A
SQ. FOOTAGE: TILE HEIGHT:N/A
CEILING HEIGHT: SOFFIT HEIGHT:N/AN/A
19,200
This drawing is propreitary information intended for representation of concepts and for discussion purposes only for the intended recipient. This is not submitted as an exact plan and is intended to bus used as a guide to the approximate room setup at this facility. Since on-site variations or adjustments may occur, PSAV is not responsible for any unauthorized use of this document
01 October 2010
RCP6RIGGINGSERVICES
DATE:REVISED BY:Lars E. Stevens 22 May 2013GRAND BALLROOM SUITE: RIGHT ISOMETRIC
Scale: 1/8" = 1'-0"
PSAV ® Presentation ServicesRigging Services
2888 Galvin ParkwayElgin, IL
CLIENTS ARE RESPONSIBLE FOR DISCLOSING ALL
RIGGED ITEMS REGARDLESS OF WEIGHT. POINT LOAD CALCULATIONS WILL BE VERIFIED PRIOR
TO LOAD-IN. UNDISCLOSED ITEMS MAY RESULT IN ADDITIONAL POINT CHARGES AND DELAYS IN SET-UP.
NOTHING IS TO BE HUNG FROM THE AIRWALL TRACKS.
PSAV RIGGING SERVICES WILL APPROVE ALL RIGGING LOADS PRIOR TO LOAD-IN DATE.
ALL HOISTS AND CONTROL WILL BE PROV BY PSAV. ALL RIGGING HARDWARE MUST MEET ANSI
STANDARDS & DISPLAY BATCH LOT IDENTIFICATION.