Highway Mixed Use District

July 27, 2009

1

Page 2: Highway Mixed Use District Presentation   20090727

Purpose of Workshop

• Confirm the need for Highway Mixed-Use District (HMU)

• Review work to date• Discuss MDP Recommendations

– Baseline HMU requirements – Solicit feedback from Council and PD&Z on

Options for HMU – Provide direction to Consultant

2

Page 3: Highway Mixed Use District Presentation   20090727

The Need• Current zoning does not accommodate mixed

uses along Manvel’s highway corridors– Allow compatible building functions to coexist in a

single zone– Protect existing single-family homes

• Develop appropriate standards for a HMU

3

Page 4: Highway Mixed Use District Presentation   20090727

Benefits of a Highway Mixed-Use District

• Allows different building functions to coexist on the same lot

• Provides opportunity for existing non-conforming properties to be conforming

• Provides new development flexibility• Maximizes tax base• Allows City to move forward in achieving its

Vision

4

Page 5: Highway Mixed Use District Presentation   20090727

Scope of Work

1. Research and evaluate industry-wide standards for mixed-use districts for consistency with Comprehensive Plan goals

2. Prepare materials for this workshop3. Prepare a draft ordinance and coordinate

with City attorney 4. Attend the PD&Z public hearing and two City

Council public hearings; prepare and present overview of draft ordinance if requested

5

Page 6: Highway Mixed Use District Presentation   20090727

WORK TO DATE

6

Page 7: Highway Mixed Use District Presentation   20090727

Work to Date - Research • Focused on best practices ordinances from

following cities:– College Station, Denton, El Paso, Hutto, Fort

Worth, Leander, Mesquite– Each of these cities have chosen, like Manvel, to

introduce form-based zoning standards– Each has some development condition that is

relevant to Manvel

7

Page 8: Highway Mixed Use District Presentation   20090727

Work to Date - Evaluate• Best practices review suggests a model

ordinance with:– Legal sufficiency and enforceability– Ease of administration– Clarity of process and textual instruction– Objective requirements and standards

• Prepared a best-practices model framework for the ordinance

• Prepared material for this presentation that includes Marsh Darcy recommendations

8

Page 9: Highway Mixed Use District Presentation   20090727

MARSH DARCY RECOMMENDATIONS

9

Page 10: Highway Mixed Use District Presentation   20090727

Recommendations Baseline: Common criteria for all HMU District options

Option 2: Highest level of additional standards and most conformity with Vision

Standard: Solves immediate need for HMU with minimal connection to Vision

Option 1: Additional standards for HMU and incremental progress toward conformity with Vision

10

Page 11: Highway Mixed Use District Presentation   20090727

HMU BASELINE REQUIREMENTS

11

Page 12: Highway Mixed Use District Presentation   20090727

Baseline Requirements

• Basic HMU Criteria:– District Area– Location– Conformance with Comp Plan– Building Functions– Buffering of pre-existing Single-Family homes

12

Page 13: Highway Mixed Use District Presentation   20090727

District Area

City Hall

• Minimum area for HMU is 60 acres

• Same size as the smallest medium PUD

• Prevents “checkerboard” of tiny HMU Districts

13

Page 14: Highway Mixed Use District Presentation   20090727

District LocationAlong both sides of a:• TXDOT designated highway

or farm to market road• Comp Plan designated

major transportation corridor

14

Page 15: Highway Mixed Use District Presentation   20090727

Conformance with Comp Plan

ID-1 Agricultural

ID-4 Urban

ID-2 Rural

ID-5 Town Center

ID-3 Suburban

SD: Master-Planned Developments already in progress

15

Page 16: Highway Mixed Use District Presentation   20090727

Permitted Building Functions

• Allows for the mix of residential and non-residential functions

• Includes functions currently allowed in current zoning districts – Single-Family Residential (SFR)– Light Commercial

• Provides process to acquire Special Use Permit for future functions

• Existing buildings can change function• More than one building function per lot

16

Page 17: Highway Mixed Use District Presentation   20090727

Protections for Existing Residential

• New building functions adjacent to existing residential units shall be required to provide a buffer of 25’

• The buffer dissolves if the previously existing residential is removed or redeveloped

BEGIN WORKSHEET

17

Page 18: Highway Mixed Use District Presentation   20090727

HMU OPTIONSStandard, Option 1, Option 2

18

Page 19: Highway Mixed Use District Presentation   20090727

District Elements

• ID Zone Location• Minimum Depth• Lot Size• Building Setback• Parking

• Building Height• Signage• Internal Buffers• Landscaping

19

Page 20: Highway Mixed Use District Presentation   20090727

ID ZONE LOCATIONStandard:ID 4, 5

Option 1:ID 4, 5, SD

Option 2:ID 3, 4, 5, SD

3

3

4

SD

5

2020

Page 21: Highway Mixed Use District Presentation   20090727

Minimum DepthDistance from the road ROW to the rear side boundary of HMU

Standard: Shall be the rear property line of all parcels adjacent to road ROW

Option 1: The nearest rear property line at or beyond 300’ from road ROW but not more than 600’

Option 2: The nearest rear property line at or beyond 600’ from road ROW but not more than 1,000’; must for provide parallel highway circulation

21

Page 22: Highway Mixed Use District Presentation   20090727

Minimum Depth

22

Page 23: Highway Mixed Use District Presentation   20090727

Minimum Lot Size

Standard: 1 acreOption 1: same as StandardOption 2: ½ acre or 21,780 sf

23

Page 24: Highway Mixed Use District Presentation   20090727

Building SetbackMinimum building setback from property line.

Standard:• 25’ from front property line; 10’ from each

side property line; 10’ from rear property line in all ID Zones

Option 1:• ID 4 – 10’ perimeter setback• ID 5 – 10’ perimeter setback• SD – 10’ perimeter setback

24

Page 25: Highway Mixed Use District Presentation   20090727

Building Setback

Option 2• ID 3 – 15’ perimeter setback• ID 4 – 10’ perimeter setback• ID 5 – 10’ frontage setback, 0’ side/rear setback• SD – 10’ frontage setback, 0’ side/rear setback

25

Page 26: Highway Mixed Use District Presentation   20090727

26

Page 27: Highway Mixed Use District Presentation   20090727

27

Page 28: Highway Mixed Use District Presentation   20090727

282828

Page 29: Highway Mixed Use District Presentation   20090727

Minimum Parking

Standard: Two spaces per residential lot; one on-site space per 250 sq ft or one space minimum regardless of square footage for non-residential

Option 1: Standard + on-site visitor space per every four residential units

29

Page 30: Highway Mixed Use District Presentation   20090727

Minimum Parking

Option 2 • Option 1 + no new parking areas between buildings and

road ROW for new buildings within 300’ of main HMU roadway

• All new parking must be at side or rear of buildings• New buildings located more than 300’ from main HMU

road do not have above restrictions• Shared parking calculation allowed

30

Page 31: Highway Mixed Use District Presentation   20090727

Building Heights

31

Page 32: Highway Mixed Use District Presentation   20090727

323232

Page 33: Highway Mixed Use District Presentation   20090727

333333

Page 34: Highway Mixed Use District Presentation   20090727

Signage

Standard: Current signage ordinance Option 1: No free standing pole signs allowed; free

standing monument signs are allowedOption 2: Option 1 + no free standing monument signs

allowed; only building and canopy signs allowed

34

Page 35: Highway Mixed Use District Presentation   20090727

Internal Buffers

Standard: NoneOption 1:• ID 4 – 20’ Internal buffer between buildings• ID 5 and SD – 0’ Internal buffer between buildings

Option 2:• ID 3 – 30’ Internal buffer between buildings• ID 4 – 20’ Internal buffer between buildings• ID 5 and SD – 0’ Internal buffer between buildings

35

Page 36: Highway Mixed Use District Presentation   20090727

36

Page 37: Highway Mixed Use District Presentation   20090727

Buffer LandscapingStandard: NoneOption 1: One evergreen tree (2.5” cal.) minimum 8’

high, maximum 25’ spacing, and evergreen shrubs capable of growing 8’ high, maximum 3’ spacing.

Option 2: Same as Option 1

373737

Page 38: Highway Mixed Use District Presentation   20090727

QUESTIONS?Thank you for your time!