High Power Pulsed I-V - Focus Microwaves · 2019-07-16 · High Power Pulsed I-V. powered by. FOCUS...

4
High Power Pulsed I-V powered by FOCUS MICROWAVES GROUP Auriga’s 5th Generation 1200V and 2000V PIV Systems V08/18

Transcript of High Power Pulsed I-V - Focus Microwaves · 2019-07-16 · High Power Pulsed I-V. powered by. FOCUS...

Page 1: High Power Pulsed I-V - Focus Microwaves · 2019-07-16 · High Power Pulsed I-V. powered by. FOCUS MICROWAVES GROUP. Auriga’s 5th Generation 1200V and 2000V PIV Systems. PULSED

High Power Pulsed I-V

powered by

FOCUS MICROWAVES GROUP

Auriga’s 5th Generation 1200V and 2000V PIV Systems

P U L S E D I V

V08/18

Page 2: High Power Pulsed I-V - Focus Microwaves · 2019-07-16 · High Power Pulsed I-V. powered by. FOCUS MICROWAVES GROUP. Auriga’s 5th Generation 1200V and 2000V PIV Systems. PULSED

1200V / 10 or 100A DRAIN PULSER

The PHD1200 supports the industry’s most advanced high-powered devices. Leveraging recent breakthroughs in component and pulser-circuit technology provides unparalleled speed, accuracy, and resolution. Dynamic on-resistance of the latest transistors can now be measured with precision.The PHD1200 operates with the AU-5 Pulsed IV/RF Characterization System; this compact and versatile test solution accurately simulates real life and delivers unparalleled performance, capturing measurements with incredible accuracy and speed.

1200V

www.focus-microwaves.com2

ModelMax Voltage

(V)Max Current

Pulsed (A)Typical Error Max Power (W)

Min. Pulse Width

Max PRFMin. Output

Rise /Fall

PHD1200-10 1200 10 0.01% 5000 1us 1.4 kHz @ 1200V 84ns*

3.525

4.700

8.000

8.000

3.176

-200

0

200

400

600

800

1000

1200

1400

0.00E+00 5.00E-07 1.00E-06 1.50E-06 2.00E-06 2.50E-06 3.00E-06 3.50E-06 4.00E-06 4.50E-06

1200V Pulsed Waveforms

time (seconds)

40A Pulsed Waveforms

time (seconds)

cu

rre

nt

-5

0

5

10

15

20

25

30

35

40

45

0.00E+00 1.00E-06 2.00E-06 3.00E-06 4.00E-06 5.00E-06 6.00E-06 7.00E-06

volt

age

PHD1200-100 1200 100 0.01% 5000 1us 1.4 kHz @ 1200V 84ns*

*Measure with open circuit

Page 3: High Power Pulsed I-V - Focus Microwaves · 2019-07-16 · High Power Pulsed I-V. powered by. FOCUS MICROWAVES GROUP. Auriga’s 5th Generation 1200V and 2000V PIV Systems. PULSED

3www.focus-microwaves.com

2000V

ModelMax Voltage

(V)Max Current

Pulsed (A)Typical Error Max Power (W)

Min. Pulse Width

Max PRFMin. Output

Rise /Fall

PHD2000-10 2000 10 0.01% 5000 4us 1.0 kHz @ 2000V 84ns*

2000V / 10 or 100A DRAIN PULSER

As GaN and other non traditional technologies continue to make inroads in high power appli-cations, design and test engineers will require high performance robust narrow pulsed IV solutions. Auriga’s new PHD2000drain puls-er head, available with the newly redesigned AU-5 Pulsed I-V measurement system, allows for pulsed measurements up to 2000V and 100A. This new high voltage offering intro-duced to the market is due to increasing demand from various industry verticals which include Automotive, Medical, Industrial, and Telecommunications.

2000V Pulsed Waveforms

time (seconds)

volt

age

100A Pulsed Waveforms

time (seconds)

cu

rre

nt

-20

0

20

40

60

80

100

120

0.00E+00 1.00E-06 2.00E-06 3.00E-06 4.00E-06 5.00E-06 6.00E-06 7.00E-06 8.00E-06 9.00E-06

-100

400

900

1400

1900

2400

0.00E+00 1.00E-06 2.00E-06 3.00E-06 4.00E-06 5.00E-06 6.00E-06 7.00E-06 8.00E-06 9.00E-06 1.00E-05

PHD2000-100 2000 100 0.01% 5000 4us 1.0 kHz @ 2000V 84ns*

*Measure with open circuit

Page 4: High Power Pulsed I-V - Focus Microwaves · 2019-07-16 · High Power Pulsed I-V. powered by. FOCUS MICROWAVES GROUP. Auriga’s 5th Generation 1200V and 2000V PIV Systems. PULSED

[email protected] www.focus-microwaves.com+1 514 684 4554

Intuitive Graphic User InterfaceAuriga version 5.1

4

±100VPulser Gate

1200V / 2000VPulser Drain

Auriga AU5 Mainframe

DUTDC High Voltage Power Supplies

FCU

Auriga software interface displaying dynamic On-resistance measurement

Typical setup for High Powered Pulsed I/V