Visual Outcomes and Satisfaction with Toric IOL Versus Monofocal IOL
High Performance IOL Power Calculation….at the push of a button
-
Upload
michael-mrochen -
Category
Health & Medicine
-
view
22 -
download
0
Transcript of High Performance IOL Power Calculation….at the push of a button
High Performance IOL Power Calculation….at the push of a button
OIS, San Diego16th April 2015
Michael Mrochen, CTO and Co Founder
IOL Power CalculationIt takes years of learning and experience!
Google search result on “IOL Power Calculation”
“latest publications”
“previous patient history” “device specific knowledge”
“surgeon specific A-constant”“Keratometer index”“Ultra-sound equivalence”
How to match the best outcomes?NHS Standard
85% within +/- 1D55% within +/- 0.5DRoyal College of Ophthalmic Cataract Surgeons Guidelines, Gale et al, 2006
More recently“With modern optical biometry for the majority of patients, informed formula choice and IOL constant optimisation outcomes of more than 90% within ±1 D and more than 60% within ±0.5 D of target are achievable”.R.Sheard, Optimising Biometry for best outcomes in cataract surgery, Eye, 2014
To achieve these results takes time for every patient and considerable expertise
The Problem
• Historical IOL power formulae are:– Good for the “average” refractive outcome (SEQ)– Poor for predicting the individual refractive outcome
• High complexity driven by variety of formulae available for– Short or long eyes– Astigmatic eyes– Post-refractive surgery eyes
• Improving refractive outcomes based on formulae requires:– Experience– Time to optimize and implement for the individual patient– Reliable historical clinical data for A-constant optimization
Mirricon –A new Ocular Biometer for High Performance IOL Power Calculation
•Results at the push of a button assuring:• Convenience – minimal training time and
improved clinic throughput
•Easy decisions without great expertise and experience delivering:
• Predictable outcomes - Excellent and consistent results every time
• Safety – Reducing the possibility of human error in IOL Power calculation
•One preoperative solution for all types of eyes
Physical Optical Testing with Model Eyes
Physical Optical Testing with Model Eyes
First in human useFirst in human use
January 2014
May 2014
May 2015
POC – study in 100 cataract eyes
POC – study in 100 cataract eyes
Status of DevelopmentApril 2014
Device developmentDevice development
Multi Million InvestmentMulti Million Investment
4 patents filed (1 approved)4 patents filed (1 approved)
R&D ProjectR&D Project
2010
What are we looking for?
Partnership opportunities with IOL and Device
companies
Partnership opportunities with IOL and Device
companies
Investment partners to execute our roadmap for commercialization
Investment partners to execute our roadmap for commercialization