HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low...

40
HID Low bays Product Catalog

Transcript of HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low...

Page 1: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

HID Low bays Product Catalog

Page 2: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

2 HOLOPHANE® | HID LOW BAYS | Introduction

HOLOPHANE®

Low Bays

HOLOPHANE LOW BAY LUMINAIRES COMBINE THE

EFFICIENCY OF HID AND FLUORESCENT LIGHT SOURCES

WITH SPECIAL LENS OPTICS TO PROVIDE A VARIETY OF

LIGHTING DISTRIBUTIONS WITH LOW BRIGHTNESS.WHILE ALL HOLOPHANE LOW BAY FIXTURES ARE

DESIGNED FOR RELIABILITY AND PERFORMANCE,SEVERAL FEATURE HEAVY DUTY CONSTRUCTION FOR

MORE DEMANDING ENVIRONMENTS.

Page 3: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

With depths as low as 12.5 inches, the low

bay fixtures include high performance

reflectors or refractors with various mounting

options to accommodate low ceiling heights

and assure the clearance needed in some

industrial applications.

These compact luminaires are available with

open bottom or covered enclosed optics to

meet specific lighting needs depending on

the fixture.

Holophane low bay luminaires are rated for

a wide range of ambient temperatures and

may be used with a variety of lamps and

wattages. The fixtures are also constructed

for installation and maintenance ease. Enduralume® V

Bantam 2000® Series

Lobay® V

Low Profile Series

Page 4: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

4 HOLOPHANE® | HID LOW BAYS | Low Profile Series

HOLOPHANE®

Low Profile Series

LOW PROFILE SERIES IS THE

SOLUTION TO LIGHTING INDUSTRIAL

AREAS WITH LOW CEILING HEIGHTS.TYPICAL APPLICATIONS INCLUDE FOOD

PROCESSING PLANTS, POWER PLANTS,MEZZANINES, STAIRWELLS AND AREAS

WHERE HANGING DUCT WORK LEAVES

MINIMAL OVERHEAD CLEARANCE.

An extensive choice of lighting dis tri bu tionsare available by combining the wide selectionof metal halide and high pressure sodiumlamps and wattages with the Enduralume®,Prismpack®, Prismalume®, or CentaGlo® optics.

All luminaires in the Low Profile Series comestandard with our pre-treatment process,white polyester powder paint and a 6 yearballast warranty.

Low Profile Series luminaires are rated for 55°Cambient temperature and UL/CUL damp locations.

Page 5: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

HOLOPHANE® | HID LOW BAYS | Low Profile Series 5

| INDOOR LIGHTING

Features and Benefits

O Compact design to accommodate minimal

overhead clearance (depths up to 12.5”)

O Superior optical performance for a full range

of applications reducing energy consumption

O Tool-less relamping for ease of maintenance

O Rugged, robust construction and

mechanical features provides longevity

O Unique mechanical features that reduce

maintenance

Typical Applications

O Industrial

O Production Areas

O Food Processing

O Electronic Manufacturing

O Loading and Storage Areas

O Parking Garages

Prismalume Optics Prismpack Optics CentaGlo Optics Enduralume Optics

Page 6: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

6 HOLOPHANE® | HID LOW BAYS | Low Profile Series

HOLOPHANE®

Applications

TODAYS SPACES ARE OFTEN CONGESTED LEAVING LITTLE

ROOM FOR NEEDED MATERIAL. OUR CEILINGS ARE OFTEN

NO DIFFERENT WITH LITTLE CLEARANCE FOR CRITICAL

LIGHTING NEEDED TO PRODUCE THE REQUIRED AMOUNT

OF LIGHT TO CREATE A PRODUCTIVE WORK ATMOSPHERE.THE LOW PROFILE SERIES OFFERS A SOLUTION TO THIS

DILEMMA PROVIDING ROBUST LUMEN PACKAGES IN A

COMPACT LUMINAIRE.

Page 7: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

HOLOPHANE® | HID LOW BAYS | Low Profile Series 7

| INDOOR LIGHTING

Manufacturing Areas

Manufacturing areas often require shallow luminaires withefficient, wide-spread, low-brightness distribution. Thecondensed side mounted ballast assembly permitsinstallation in areas with low ceilings or in between trussesso that cranes, forklifts and other moving machinery canpass without interference.

Loading and Storage Areas

Four standard Holophane optics are available for the LowProfile Series all having lamps available from 150 to 400watts. In addition to the versatility of the optics, the LowProfile Series has features which make maintenance abreeze – perfect for loading and storage areas. The lowprofile design is ideal for limited space ceilings giving evengreater flexibility for design criteria. The prismatic glassreflectors are available covered, which minimizes uplight, oruncovered, which produces about 15% uplight, increasingvertical footcandles.

Production Areas

Open bottom reflectors circulate air, keeping the fixtureclean and cool even in the dirtiest of environments. Sinceborosilicate glass contains no static charge and is non-yellowing the Low Profile Series luminaire needs minimalmaintenance. Energy saving ballasts are available for MH,HPS and Pulse Start Metal Halide lamps.

Parking Garages

The Low Profile Series has distributions to suit a wide rangeof applications within a typical parking garage. Asymmetrical distribution may be used for large open areaswhile the asymmetric distribution is ideal for drive and aisleways. Available in low profile wide or narrow distributions,the Low Profile Series is well suited for low mountingheights to achieve desired light levels.

Page 8: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

Low Profile Series

Zinc Steel Yoke

Pendant Top with Sliding Adaptor

Borosilicate Glass or Acrylic Refractor

Enduralume Spun Reflector

Zinc Plated Steel Rods and Rings

Superior Optics

Steel Support Assembly

Heavy Duty Ballast Housing

8 HOLOPHANE® | HID LOW BAYS | Low Profile Series

HOLOPHANE®

Steel Support Assembly hasthumbscrews that easily attachesoptic to steel support.

Steel Support Assembly offersheavy duty, 14 gauge formed steel support assembly with cov ered wire way.

Choice of Four Optics made fromborosilicate glass minimize light lumendepreciation by minimizing accumulateddirt on the inner surface of the reflector.

Enduralume low profile, spun aluminumreflector: Finished inside and out withwhite high-re flec tance polyester powder-paint. A prismatic boro sil i cate glass oracrylic refractor: Provides uniform surfacebrightness and pre cise ly controlledvertical il lu mi na tion.

Heavy Duty Die Cast AluminumBallast Housing is poly es ter powder-painted and suspended below the steelcross arm in a low profile design forlimited mounting height applications.

Zinc Steel Yoke attaches to theelectrical housing with a steel hangerand latch for ease of installation.

Pendant Top with Sliding Adaptorprovides proper balance on swivelhangers, with DN20NPT (.75”) thread edconduit entry, or an optional thru-wiringbox.

Page 9: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

HOLOPHANE® | HID LOW BAYS | Low Profile Series 9

| INDOOR LIGHTING

Ordering Information

Dimensional Details and Light Distribution Charts

LP - Prismalume OpticsMaximum Weight: 22 kg (48.5 lbs.)

LC - CentaGlo OpticsMaximum Weight: 27 kg (59.5 lbs.)

LEN - Enduralume OpticsMaximum Weight: 27 kg (59.5 lbs.)

LK - Prismpack OpticsMaximum Weight: 22 kg (48.5 lbs.) LK A mm (in.) B mm (in.) C mm (in.)

6611-AL 457 (18.0”) 654 (25.75”) 596 (23.45”)6612-AL 565 (22.25”) 708 (27.88”) 649 (25.55”)

LP A mm (in.) B mm (in.) C mm (in.)6611 480 (18.9”) 674 (26.55”) 538 (21.2”)6612 592 (23.3”) 729 (28.7”) 592 (23.3”)

Spacing to Mtg. Ht. Ratio

LAMP SOURCE AND WATTAGE

HIGH PRESSURE SODIUM METAL HALIDE

15AHP 250W 400W 175W - 320W 350W - 400W

0 - 1.2:1 Q12 L12 I12 Q12 N12

1.2:1 - 2.2:1 Q11 L11 I11 Q11 N11

Spacing to Mtg. Ht. Ratio

LAMP SOURCE AND WATTAGE

HIGH PRESSURE SODIUM METAL HALIDE

15AHP 250W 400W 175W - 320W 350W - 400W

0 - 1.2:1 Q12 L12 Q12 Q12 N12

1.2:1 - 2.2:1 Q11 L11 L11 Q11 N11

Spacing to Mtg. Ht. Ratio

LAMP SOURCE AND WATTAGE

HIGH PRESSURE SODIUM METAL HALIDE

15AHP 250W - 400W 175W - 320W 350W - 400W

CG1 asymmetric Narrow M1 E1 M1 B1

CG1 asymmetric Wide H1 M1 D1 D1

CG2 Symmetric 1.1:1 M2 E2 M2 B2

CG2 Symmetric 1.4:1 N2 C2 N2 A2

Page 10: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

10 HOLOPHANE® | HID LOW BAYS | Low Profile Series

HOLOPHANE®

Specifications

Complete luminaire shall be Holophane Low Profile Series catalog number ______. Theluminaire shall consist of a low profile mounting assembly to which is at tached a ballasthous ing and an optical re flec tor/refractor assembly. The entire as sem bly shall be a max i mumof ____ deep. It shall be C/UL/US listed 1598 for damp lo ca tions up to 55°C (40°C for 400Wwith Enduralume acrylic lens).

The low profile mount ing assembly shall have a cast aluminum adjustable hub for .75”conduit rigid pendant mounting or for balanced luminaire support from hooks or loops.Mounting hooks and loops shall be self lubricating malleable cast iron and protected againstcorrosion with zinc plated chromate finish. The rigid formed steel housing mount ingassembly, and the ballast housing shall be protected against corrosion by a seven stage pre -treat ment fol lowed by electrostatically applied polyester powder paint, which meets ASTMstandard practices for hard ness, humidity, impact and salt spray resistance to prevent crosshatch creep, fading, cracking and other corrosion related de te ri o ra tion.

Optics (Choose One)Enduralume® OpticsThe standard optical as sem bly shall consist of a 510mm (20”) di am e ter aluminum reflectorwith a minimum 90% re flec tance, white baked polyester powder paint finish com bined with a spun-on dropped pris mat ic boro sil i cate glass or acrylic refractor. The refractor shall be 120mm (4.75”) deep with precisely formed prisms producing a sym met ri cal light dis tri bu tion.

The optical assembly shall swing open yet stay attached to the housing so that no tools shallbe required for relamping. The porcelain enclosed mogul base socket with corrosionresistant, nickel plated, lamp grip screw shall be factory prewired and set for op ti mum lightdis tri bu tion.

Prismpack® OpticsGlass reflector shall be Endural® prismatic boro sil i cate glass with a minimum wall thicknessof 3mm (.13”). Reflector shall have a per ma nent ly spun-on and sealed anodized aluminumcover.

The zinc plated steel, reflector attachment yoke shall have swingover locking lugs whichprevent ac ci den tal dis lodg ing. Integral support provision for full ven ti la tion and optionalsafety chain shall be pro vid ed. No tools shall be required to attach or detach the reflectorfrom the housing. The smooth inner glass sur face shall not deteriorate in normal in dus tri alat mo spheres and shall return to original reflecting values after cleaning.

Prismalume® OpticsGlass reflector shall be Endural® prismatic boro sil i cate glass with a minimum wall thicknessof 3mm (.13”). It shall be firmly supported by a zinc plated wire frame from the bottom ofthe reflector. The zinc plated steel, reflector attachment yoke shall have swingover lockinglugs which prevent ac ci den tal dislodging. Integral support provision for full ventilation andoptional safety chain shall be pro vid ed. No tools shall be required to attach or detach thereflector from the housing. The smooth inner glass surface shall not deteriorate in normalindustrial at mo spheres and shall return to original re flec tive values after cleaning.

CentaGlo® OpticsFixture shall include an optical assembly composed of an Endural® prismatic glass reflectorand refractor permanently joined together. The upper component shall be a reflectorpermitting uplight in a controlled area while also reflecting light back into the lowerrefractor. The refractor shall be available in either a symmetrical or asymmetricaldistribution.

Mounting assemblySee page 32-33 for the performance specifications on the mounting options that areavailable

Certain airborne contaminants can diminish the integrity of acrylic. Please refer to the Acrylic Environmental Compatibility Chart (HL-2445) for suitable uses.

Prismalume Optics

Prismpack Optics CentaGlo Optics

Enduralume Optics

DISTRIBUTIONS

K MOUNTING

K Quick install thru-wiring for Low Profile Series

Page 11: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

HOLOPHANE® | HID LOW BAYS | Low Profile Series 11

| INDOOR LIGHTING

STEP 1: LUMINAIRE

LC Low Profile CentaGloLEN Low Profile EnduralumeLK Low Profile PrismpackLP Low Profile Prismalume

STEP 2: SOURCE AND WATTAGE

HIGH PRESSURE SODIUM15AHP 150W/55V HPS250HP 250W HPS400HP 400W HPSEnergy Saving25LHP 250W HPS40LHP 400W HPS

METAL HALIDE175MP 2, 3 175W MH, protected250MH 1, 3 250W MH250MP 2, 3 250W MH, protected400MH 3 400W MH400MP 2, 3 400W MH protectedEnergy Saving25LMP 2, 3 250W MH, protected40LMH 3 400W MH40LMP 3 400W MH, protected

1 Only available with LEN optic2 Not available with LEN optic3 Not available for shipment in US after

Dec. 31, 2008, due to EISA legislation

4 Meets US Federal EISA legislation

Preferred Selections:

Catalog Numbers for Entire Product Offering(Pricing and lead times may be affected)

Most Frequently Ordered Catalog Numbers

LEN1

LUMINAIRE

LCLENLKLP

400PM2

WATTAGE

400PM

273

VOLTAGE

27

K4

MOUNTING

K

N5

CORD LENGTH

N

G6

OPTICS

G

EM7

OPTIONS

EM

PF-2918

ACCESSORIES

PF-291

STEP 5: CORD LENGTH

N None, “P” or “K” mountingonly

R 3 feet, not available with ‘P”or “K” mounting.

F 5 feet, “T” mounting onlyS 6 feet, not available with “P”,

“K” or “T” only.T 10 feet, not available with ‘P”

or “K” mounting.

STEP 6: OPTICS

LEN - EnduralumeG Glass refractorA1 Acrylic refractor

1 40ºC ambient only

See charts on page 9 for LC, LPand LK optics

STEP 7: OPTIONS

Factory Installed.See page 35 for a complete list of options and product availability

STEP 8: ACCESSORIES

Ships Separately.See page 35 for a complete list ofaccessories and product availability

STEP 3: VOLTAGE

08 1 208V40 1 240V12 120V20 208V24 240V27 277V34 347V48 480VMulti-voltageMA Prewired for 120VMB Prewired for 208VMC Prewired for 240VMD Prewired for 277VMT Multi-voltageVT 2 Vari-tap

1 Isolated secondary, CUL. Not availablewith 250PP, 25LPP, 25LPM, 320PP,35LPM, 400PM, 400PP, 40LPP and40LPM, handled through TSG

2 120, 277, 347V, Canada. Available with250HP, 400HP, 250MP, 250PP, 25LPP,320PP, 350PM, 35LPM, 400MH and400MP

STEP 4: MOUNTING

P PendantK 1, 3 Quick install thru-wiringPF-455 Cast Hook and HoloflexB 2 “L” cord dropF 2 “T” cord dropT 2 Selectable cord drop

1 40°C ambient only2 UL dry location only. Handled through

TSG3 Not available with LC optic

STEP 2: SOURCE (CONTINUED)

PULSE START METAL HALIDE175PM 1, 4 175W PMH250PM 1, 4 250W PMH250PP 2, 4 250W PMH, protected320PM 1, 4 320W PMH320PP 2, 4 320W PMH, protected350PM 1, 4 350W PMH350PP 2, 4 350W PMH, protected400PM 1, 4 400W PMH400PP 2, 4 400W PMH, protectedEnergy Saving25LPM 1, 4 250W PMH35LPM 1, 4 350W PMH35LPP 2, 4 350W PMH, protected40LPM 1, 4 400W PMH40LPP 2, 4 400W PMH, protected

1 Only available with LEN optic2 Not available with LEN optic3 Not available for shipment in US after

Dec. 31, 2008, due to EISA legislation

4 Meets US Federal EISA legislation

Page 12: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

12 HOLOPHANE® | HID LOW BAYS | Bantam 2000 Series

HOLOPHANE®

Bantam 2000® Series

BANTAM 2000 SERIES IS THE PERFECT

FIXTURE FOR A VARIETY OF HEAVY DUTY

INDUSTRIAL AND LOW CEILING HEIGHT

APPLICATIONS.

LOW PROFILE DESIGN CHARACTERIZES

UNITS IN THE BANTAM 2000 SERIES,PROVIDING CLEARANCE IN LOW CEILING

HEIGHTS.

Available in a range of low wattage HIDlamps, Bantam 2000 Series luminairesprovide required lighting in an energyefficient manner.

Bantam 2000 Series fixtures areavailable in a choice of four ruggedglass optics that efficiently place lightwhere visibility is needed.

Rated for a wide range of ambienttemperature applications, Bantam 2000Series fixtures are also listed for wet ordamp locations.

Page 13: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

HOLOPHANE® | HID LOW BAYS | Bantam 2000 Series 13

| INDOOR LIGHTING

Features and Benefits

O Engineered for low maintenance

O Choice of mounting options offers flexibility

in design for virtually any application

O Heavy duty construction and mechanical

features provides longevity and ease of

maintenance

O Efficient operation for increased energy

savings

Typical Applications

O Mezzanines

O Parking Garages

O Retail Stores

O Stairwells

O Textile Mills

O Distribution Warehouses

Prismalume Optics Prismpack Optics Prismatite Optics Enduralume Optics

Page 14: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

14 HOLOPHANE® | HID LOW BAYS | Bantam 2000 Series

HOLOPHANE®

Applications

TYPICAL APPLICATIONS FOR LUMINAIRES

IN THE BANTAM 2000 SERIES INCLUDE

MEZZANINES, PARKING GARAGES, RETAIL

STORES AND STAIRWELLS WITH LOW OR

CONGESTED CEILINGS.

Page 15: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

HOLOPHANE® | HID LOW BAYS | Bantam 2000 Series 15

| INDOOR LIGHTING

Textile Mills

Textile mills with low ceiling heights often require shallowluminaires with efficient, wide-spread, low-brightnessdistribution. The Bantam’s smaller size and lower wattagepackages permits installation in areas with low ceilings or inbetween trusses so that cranes, forklifts and other movingmachinery can pass without interference.

Distribution Warehouses

Four standard Holophane optics are available for theBantam Series all having lamps available from 50 to 175watts. Besides the versatility of the optics, the BantamSeries has features which make maintenance a breeze –perfect for distribution and warehouse areas. At less than16” deep, the low wattage design is ideal for limited spaceceilings giving even greater flexibility for design criteria. The prismatic glass reflectors are available covered, whichminimizes uplight, or uncovered, which produces about15% uplight, increasing vertical footcandles.

Parking Garages

The Bantam Series has distributions to suit a wide range ofapplications within a typical parking garage. A symmetricaldistribution may be used for large open areas while theasymmetric distribution is ideal for drive and aisle ways.Available in low wattage wide or narrow distributions, theBantam Series is well suited for low mounting heights toachieve desired light levels.

Steel Mills

Open bottom reflectors circulate air, keeping the fixtureclean and cool even in the dirtiest of environments. Since borosilicate glass contains no static charge and is non-yellowing, the Bantam Series luminaire needs minimalmaintenance. Energy saving ballasts are available for MH,HPS and Pulse Start Metal Halide lamps.

Page 16: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

16 HOLOPHANE® | HID LOW BAYS | Bantam 2000 Series

HOLOPHANE®

Low Profile Series

Choice of Four Optics made from borosilicate glass minimize lightlumen depreciation by minimizing accumulated dirt on the inner surfaceof the reflector.

Heavy Duty Die Cast Aluminum BallastHousing is pretreated and coated with poly es ter powder-paint

Tool-lessStainless SteelHardware helpsprevent corrosion

Variety of MountingOptions available inceiling, pendant,stanchion and wallmountings.

Zinc Plated Steel Rods and Ringsoffers rugged construction andproduct longevity

Enduralume Spun Reflector is finishedinside and out with white high-re flec tancepolyester powder-paint.

Heavy Duty Ballast Housing

Tool-less Stainless Steel Hardware

Superior Optics

Zinc Plated Steel Rods and Rings

Borosilicate Glass or Acrylic

Enduralume Spun Reflector

Heavy Duty Ballast Housing

Variety of Mounting Options

Reflectors and Refractors provide uniform surface brightness and pre cise ly controlled vertical il lu mi na tion.

Page 17: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

HOLOPHANE® | HID LOW BAYS | Bantam 2000 Series 17

| INDOOR LIGHTING

Ordering Information

Dimensional Details

Mountings

Luminaires

H/K/L/S - Prismalume OpticsMaximum Weight: 9.07 kg (20 lbs)

B/G - Prismatite OpticsMaximum Weight: : 9.07 kg (20 lbs)

A/C - Enduralume OpticsMaximum Weight: :

Medium Base 7.2 kg (16 lbs)Mogul Base 11.8 kg (26 lbs)

M/N/U - Prismpack OpticsMaximum Weight: : 9.07 kg (20 lbs)

A - Stanchion W - Wall BracketC - Ceiling

Page 18: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

18 HOLOPHANE® | HID LOW BAYS | Bantam 2000 Series

HOLOPHANE®

Specifications

Complete luminaire shall be Holophane Bantam 2000 catalog number_______________. The luminaire shall consist of an optical assembly which is attachedto an integral ballast housing. The complete luminaire shall be UL listed for WetLocation and CSA certified. It shall be bal anced without external ad just ment whensupported by hooks or loops and shall have a stainless steel relamping cable betweenhousing and optical as sem bly.

The die cast aluminum housing shall incorporate a wiring chamber for 90°C wire,threaded entry for DN20NPT (.75") conduit en trance with set screw, stainless steelfinger op er at ed double action latches, and have a cor ro sion resistant, white, baked onpolyester powder paint, over a 7 stage pretreatment process.

Optics (Choose one)The optics shall be supported by a die cast aluminum door plate with integral latchstrike surfaces. A cast in notch shall properly align the door to the housing so that noadjustment is needed for designed photometric performance.

Enduralume® OpticsOptical assembly shall consist of an enclosed prismatic borosilicate glass or acrylicrefractor and spun alu mi num reflector. Re flec tor and door plate shall have the samefinish as the housing.

Prismalume® OpticsOptical assembly shall consist of an (open or enclosed) prismatic bo ro sil i cate glassreflector sup port ed by three can ti le ver zinc chromate finished rods engineered for correct tension between the door plate and reflector ring.

Prismpack® OpticsOptical assembly shall consist of an (open or enclosed) prismatic bo ro sil i cate glassreflector with spun on anodized alu mi num cover attached to the white door plate.

Prismatite® OpticsOptical assembly shall consist of a prismatic borosilicate glass refractor with eithersymmetric or long and narrow dis tri bu tion.

Mounting assemblySee page 32-33 for the performance specifications on the mounting optionsthat are available

Certain airborne contaminants can diminish the integrity of acrylic.Please refer to the Acrylic Environmental Compatibility Chart (HL-2445) for suitable uses.

DISTRIBUTIONS

AMBIENT TEMPERATURE CHART

Enduralume Optics (A) Prismalume Optics (L)

Prismpack Optics (Z) Prismatite Optics (G)

*UL Listed Ambient Temperature Chart

Optic Lamp

Suffix Metal Halide High Pressure Sodium

Description No. 70W 100W 150W 175W 50W 70W 100W 150W

Enduralume® A & C 65°C 65°C 55°C 40°C 75°C 65°C 55°C 55°C

Prismatite® B & G 65°C 55°C 40°C 40°C 75°C 65°C 55°C 55°C

Prismpack® Open M & N N/A N/A N/A N/A 75°C 65°C 55°C 55°C

Prismpack® Enclosed U & Z 65°C 65°C 55°C 40°C 75°C 65°C 55°C 55°C

Prismalume® Open H & J N/A N/A N/A N/A 75°C 65°C 55°C 55°C

Prismalume® Enclosed K & L 65°C 65°C 40°C 40°C 75°C 65°C 55°C 55°C

Page 19: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

HOLOPHANE® | HID LOW BAYS | Bantam 2000 Series 19

| INDOOR LIGHTING

STEP 1: LUMINAIRE

BA Bantam 2000 Series

STEP 2: SOURCE AND WATTAGE

HIGH PRESSURE SODIUMMedium Base50DHP 1 50W HPS70DHP 70W HPS10DHP 100W HPS15DHP 150W HPSMogul Base070HP 2 70W HPS100HP 2 100W HPS15AHP 2 150W HPS

METAL HALIDEMedium Base70DMH 3, 5 70W MH10DMH 3, 5 100W MH15DMH 3, 5 150W MH17DMH 3, 5 175W MH70DMP 4, 5 70W MH, protected10DMP 4, 5 100W MH, protected15DMP 4, 5 150W MH, protectedMogul Base175MH 2, 5 175W MH1 Not available with 347V. CUL listed2 Available with “A” and “C” optics

only3 Enclosed only. Not available with 480V4 Open optics only. Sockets accept open

rated lamps only. Not available withmedium base lamps, 347V or 480V

5 Not available for shipment in US afterDec. 31, 2008, due to EISA legislation

Preferred Selections:

Catalog Numbers for Entire Product Offering(Pricing and lead times may be affected)

Most Frequently Ordered Catalog Numbers

BA1

LUMINAIRE

BA

70DHP2

WATTAGE

70DHP

123

VOLTAGE

12

P4

MOUNTING

P

A5

OPTICS

A

EM6

OPTIONS

EM

PF-2917

ACCESSORIES

PF-291

STEP 5: OPTICS

Enclosed bottomA Enduralume glassB Long and narrow PrismatiteC Enduralume acrylic G Symmetric Prismatite

Open bottomK Wide distribution PrismalumeL Medium distribution

PrismalumeU Wide distribution PrismpackZ Medium distribution

PrismpackH Wide distribution PrismalumeJ Medium distribution

PrismalumeM Wide distribution PrismpackN Medium distribution

Prismpack

STEP 6: OPTIONS

Factory Installed.See page 37 for a complete list of options and product availability

STEP 7: ACCESSORIES

Ships Separately.See page 37 for a complete list ofaccessories and product availability

STEP 2: SOURCE (CONTINUED)

PULSE START METAL HALIDEMogul Base17DPM 3, 6 175W PMH175PM 2, 6 175W PMH2 Available with “A” and “C” optics only3 Enclosed only. Not available with 480V

6 Meets US Federal EISA legislation

STEP 3: VOLTAGE

08 1 208V12 120V20 208V24 240V27 277V34 2 347V40 1 240V48 2 480V

Multi-voltageMA Prewired for 120VMB Prewired for 208VMC Prewired for 240VMD Prewired for 277VMT Multi-voltage

1 Must be handled through TSG2 Not available with 15DMP

STEP 4: MOUNTING

A Stanchion mountC 1 CeilingP PendantW Wall bracket1 Damp location only2 Bracket arm is 1.50” NPT

Page 20: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

20 HOLOPHANE® | HID LOW BAYS | Lobay V

HOLOPHANE®

Lobay® V

THE LOBAY V LUMINAIRE COMBINES

THE EFFICIENCY OF HID LIGHT

SOURCES WITH SPECIAL LENS OPTICS

TO CREATE AN ENCLOSED LUMINAIRE

THAT PRODUCES A WIDE VARIETY OF

LIGHTING DISTRIBUTIONS. THIS MAKES

LOBAY V LUMINAIRES AN EXCELLENT

CHOICE WHEN EVALUATING BOTH

INSTALLATION AND OPERATING

ECONOMICS.

The Lobay V luminaire achieves a wide squaredistribution by utilizing a unique optical assembly. It consists of an aluminum reflectorwith white baked-on enamel applied to theinterior and exterior surface. This contourand paint treatment has been precisionengineered to provide, with the proper lens,spacing criteria of 1.3 and 1.4. The squaredistribution is achieved by the Quadrature®

lens. This unique lens is injection molded withthe visual appearance of four separatequadrants joined at the center. This lensprovides a wide square distribution withexcellent horizontal and vertical illumination.

Page 21: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

HOLOPHANE® | HID LOW BAYS | Lobay V 21

| INDOOR LIGHTING

Features and Benefits

O Engineered for low maintenance

O Choice of mounting options offers flexibility

in design for virtually any application

O Heavy duty construction and mechanical

features provides longevity

O Efficient operation for energy savings

O Optional “wet location” listing for

appropriate applications

Typical Applications

O Inspection Areas

O Production Areas

O Paper Mills

O Super Markets

Page 22: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

22 HOLOPHANE® | HID LOW BAYS | Lobay V

HOLOPHANE®

Distribution Centers

The Lobay V series incorporates aRefractive Grid® lens with analuminum cover for outstanding glarecontrol. The Refractive Grid lens isinjection molded with a preciselyformed array of hemisphericalrefractive elements on both the upperand lower sides of the lens. Theseoptical elements freely transmit thedownward light while interceptingpotential glare and redirects it touseful light for the work area.

Production Areas

Where excessive moisture is prevalent,a special version of the Lobay Vluminaire which is UL listed as“suitable for wet locations” isavailable as an option. Additionally, toprevent unwanted downtime inproduction areas, the Lobay V wasdesigned for ease of maintenance. Torelamp, simply unlatch the door andallow it to hinge downward, or lift offand remove as desired. After thelamp has been changed, merely swingthe door up and latch using yourhands – relamp without using tools.

Parking Garages

The Lobay V Series has an optionalsquare distribution to suit a widerange of applications within a typicalparking garage. A square distributionis ideal for large open areas wherelight from adjacent fixtures contributesto provide excellent uniformity. Evenhorizontal and vertical illumination isdesired for increased safety toeliminate dark areas where intrudersor muggers may be hiding. Tomaximize performance over time,simply wipe the inner surface of thereflector and the tempered glass heatshield with a soft cloth.

Applications

Page 23: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

HOLOPHANE® | HID LOW BAYS | Lobay V 23

| INDOOR LIGHTING

Heavy Duty Ballast Housing

Variety of Mounting Options

Closed Top Optical Assembly

Hinged Door Frame

Spun Aluminum Cover

Quadrature® Lens

Variety of Mounting Options with quick install slide on pendantmounting plate: Optional “quick disconnect” support for applicationflexibility and “disconnect under load” capability.

Heavy Duty Ballast Housing is pretreatedand coated with electrostatically applied,thermally set white polyester powder paint.

Spun Aluminum Cover has the interiorand exterior painted white, and properlens combine to provide distinct lightingdistributions.

Hinged Door Frame is removable andpermits easy relamping

Page 24: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

24 HOLOPHANE® | HID LOW BAYS | Lobay V

HOLOPHANE®

Ordering InformationDimensional Details

Specifications Distributions

SQ10 - Square distribution

GD10 - Refractive GridComplete luminaire shall be Holophane catalog number ________.The luminaire shall consist of two sub-assemblies: ballast assembly,containing the electrical components, mounting hardware, andreflector attachment lugs; and the optical assembly.

The complete luminaire shall be UL listed to U.S. and Canadian safetystandards as suitable for use in damp locations and ambients of up to40°C as standard.

Ballast AssemblyThe cast aluminum ballast housing shall be protected by a phosphatepretreatment followed by a sprayed on and cured polyester powderpaint. This finish is tested in accordance with ASTM standards forhardness, humidity, impact and salt spray resistance to prevent crosshatch, fading, cracking, and other corrosion related deterioration. Allhardware shall be zinc plated for corrosion protection.

Optical AssemblyThe optical assembly shall be an aluminum reflector with whitebaked on enamel on the outside and to the internal reflectingsurface. The door will contain, in a frame, the Quadrature® orRefractive Grid® lens with a clear tempered glass roundel betweenthe lamp and the lens. When the door is in place, hinged andlatched, the optical assembly will be enclosed.

Mounting AssemblySee page 32-33 for the performance specifications on the mountingoptions that are available.

Certain airborne contaminants can diminish the integrity ofacrylic. Please refer to the Acrylic Environmental CompatibilityChart (HL-2445) for suitable uses.

Page 25: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

HOLOPHANE® | HID LOW BAYS | Lobay V 25

| INDOOR LIGHTING

STEP 1: LUMINAIRE

LY Lobay V

STEP 2: SOURCE AND WATTAGE

HIGH PRESSURE SODIUM250HP 250W HPS400HP 400W HPSEnergy Saving25LHP 250W HPS40LHP 400W HPSMETAL HALIDE175MH 1 175W MH250MH 1 250W MH400MH 1 400W MHEnergy Saving25LMH 1 250W MH40LMH 1 400W MHPULSE START METAL HALIDE175PM 2 175W PMH250PM 2 250W PMH320PM 2 320W PMH350PM 2 350W PMH400PM 2 400W PMHEnergy Saving35LPM 2 350W PMH40LPM 2 400W PMH1 Not available for shipment in US after

Dec. 31, 2008, due to EISA legislation

2 Meets US Federal EISA legislation

Preferred Selections:

Catalog Numbers for Entire Product Offering(Pricing and lead times may be affected)

Most Frequently Ordered Catalog Numbers

LY1

LUMINAIRE

LY

400HP2

WATTAGE

400HP

123

VOLTAGE

12

Q4

MOUNTING

Q

SQ105

OPTICS

SQ10

F16

OPTIONS

F1

PF-121-A7

ACCESSORIES

PF-121-A

STEP 3: VOLTAGE

08 1 208V12 120V20 208V24 240V27 277V34 347V40 1 240V48 480VMulti-voltageMA Prewired for 120VMB Prewired for 208VMC Prewired for 240VMD Prewired for 277VMT Multi-voltageVT 2 Vari-tap

1 Must be handled through TSG2 Available with 250HP, 250MH, 250PM,

25LPM, 320PM, 35LPM, 350PM,400HP, 400MH only

STEP 4: MOUNTING

N Non quick disconnectpower hanger

P Pendant mount, .75” NPTconduit

Q Quick disconnect powerhanger

STEP 5: OPTICS

SQ10 Square distribution, 1.3spacing criteria

GD10 Refractive Grid, 1.4spacing criteria

STEP 6: OPTIONS

Factory Installed.See page 39 for a complete list of options and product availability

STEP 7: ACCESSORIES

Ships Separately.See page 39 for a complete list ofaccessories and product availability

Page 26: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

26 HOLOPHANE® | HID LOW BAYS | Enduralume V

HOLOPHANE®

ENDURALUME® V

THE ENDURALUME V LUMINAIRE IS AN

EFFICIENT, LOW BRIGHTNESS UNIT FOR

LIGHTING BOTH INDUSTRIAL AND

COMMERCIAL AREAS. WHETHER IT BE

SCHOOLS, FOOD PROCESSING AREAS

OR WAREHOUSES, THIS IS A GREAT

LUMINAIRE IN TERMS OF ENERGY

EFFICIENCY AND SAFETY.

In today’s society, energy efficiency is adriving concern. Energy use of a luminaireover it’s lifetime will result in the greatestenvironmental impact. The Enduralume Vluminaire meets those needs. It isavailable in MH, pulse start or HPS lampsand also with regular or low loss ballasts,in wattages ranging from 175-400W. Inaddition, for greater energy efficiency, theEnduralume V is now available with ourelectronic HID ballast in wattages rangingfrom 320-400W MH.

Page 27: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

HOLOPHANE® | HID LOW BAYS | Enduralume V 27

| INDOOR LIGHTING

Features and Benefits

O Engineered for low maintenance

O Choice of mounting options offers

versatility in design for any application

O Heavy duty construction and mechanical

features provides longevity

O Efficient operation for energy savings

O Reflector top combined with the prismatic

bottom allows minimal uplight while

maintaining good, vertical footcandles

Typical Applications

O Electric Utilities

O Post Offices

O Distribution Warehouses

O Textile Mills

O Steel Mills

O Process Industries

Page 28: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

28 HOLOPHANE® | HID LOW BAYS | Enduralume V

HOLOPHANE®

Process IndustriesThere are applications where the conditions require anenclosed luminaire producing ef fi cient, wide spread lightingdistribution. The Enduralume V luminaire combines a whitepainted highly reflective reflector with a spun on borosilicateglass or acrylic refractor. The reflector/refractor combinationresults in a low brightness appearance providing an efficientblend of hor i zon tal and vertical illumination.

Warehouse LightingThe Enduralume luminaire‘s unique design of combining analuminum reflector with a drop prismatic glass refractorresults in high vertical footcandles. Vertical footcandles areessential in stack lighting where it is necessary to read labelson boxes. Also, by having the luminaire enclosed, it meetsUL requirements of containing a MH lamp in case of non-passive lamp failure. This is often important in warehouseareas where there is the potential for damage if lamps arenot contained properly.

Post OfficesThe Enduralume V luminaire, with its enclosed optics, issuited for moderately dirty en vi ron ments as well as cleanareas. The luminaire will provide long life and easymaintenance as re quired by these ap pli ca tions. Itsappearance and rug ged ness permit it to be equally at homein commercial as well as industrial applications.

Food Processing AreasSimilar to warehouse lighting, an enclosed luminaire isessential for safety in food handling areas. The acrylicrefractor is a good choice for this application and alsoprovides uniform light and is impact resistant.

Besides the application benefits of the Enduralume Vluminaire, it is also a structurally sound unit. A relamp cablesecures the reflector to the ballast housing when relamping.Gaskets are located at the reflector/ballast and the reflector/refractor connections to minimize dirt entering the opticalassembly.

Applications

Page 29: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

HOLOPHANE® | HID LOW BAYS | Enduralume V 29

| INDOOR LIGHTING

Heavy Duty Ballast Housing

Variety of Mounting Options

Stainless Steel Latch

Borosilicate Glass or Acrylic Refractor

Spun On Reflector

Variety of Mounting Options with quick install slide on pendantmounting plate: Optional “quick disconnect” support for applicationflexibility and “disconnect under load” capability.

Heavy Duty Ballast Housing is pretreatedand coated with electrostatically applied,thermally set white polyester powder paint.

Spun On Refractor with Dropped Pris mat ic Boro sil i cate Glass or AcrylicRefractor. The refractor is 121mm (4.75”)deep with precisely formed prismsproducing a sym met ri cal light distribution.

Stainless Steel Latch features swing-overlocking springs to prevent accidental dis lodg ing. A stainless steel cable supportsthe optics. No tools are required to unlatchthe optics from the housing.

Page 30: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

30 HOLOPHANE® | HID LOW BAYS | Enduralume V

HOLOPHANE®

Ordering InformationDimensional Details

Specifications DistributionsGeneralComplete luminaire shall be Enduralume V catalognumber __________. The luminaire shall consist of twosub-assemblies: ballast assembly containing the electricalcomponents and an optical reflector/refractor.

The complete luminaire shall be listed by Un der writ ersLaboratories, Inc. as suitable for use in damp locationambients of up to 55°C as standard, (40°C for 400Wmetal halide with acrylic re frac tor). Op tion al wet locationlu mi naire shall be listed for 40°C.

The factory installed stainless steel reflector attachmentlatches shall have swingover locking springs, so as toprevent accidental dis lodg ing. A stainless steel cable shallsupport the optics during relamping. No tools shall berequired to unlatch the optics from the housing. Thesupport casting shall contain a fiberglass filter and an EPTgasket which is compressed when the optical assembly islatched in place.

Optical AssemblyThe optical assembly shall encompass a 508mm (20”) di am e ter aluminum re flec tor with a 90% reflectance,white baked polyester powder paint finish com bined witha spun on dropped pris mat ic boro sil i cate glass or acrylicrefractor. The refractor shall be 121mm (4.75”) deep withprecisely formed prisms producing a sym met ri cal lightdistribution.

Mounting AssemblySee page 32-33 for the performance specificationson the mounting options that are available

Electronic BallastThe HID electronic ballast shall be provided withintegral color coded leads. This electronic ballastshall be multi-voltage capable and shall operatefrom a nominal voltage range of 208 – 277 voltsAC. The electronic ballast shall have a systemefficiency of greater than 93% under full lampoperation. It shall be FCC compliant for EMI/RFI asper parts 18.305 and 18.307. Total harmoniccurrent distortion shall be less than 15%. Startinginput current shall be less than stabilized lampoperating current. The ballast system shall be

capable of maintaining stabilized lamp operationthrough one full cycle of power interruption.Electrical system shall withstand transient peaks ofseven strikes of 100kHz ring waves at 2.5kV levelfor both common and differential mode per IEEEC62.41.

The ballast shall be capable of powering one 400,350 or 320 watt pulse start metal halide lamp.Lamp wattage shall not vary more than ± 3.0% fora ±10% change in input line voltage. A crest factorof 1.5 shall not be exceeded. Lamps operating onthe ballast shall be warranted by the lampmanufacturer to deliver improved mean lumens ascompared to same lamp operation on anelectromagnetic ballast. Where applicable, a meansof continuous dimming shall be a part of the ballastsystem.

Dimming control is to be of the common 0–10 voltDC. 0-10VDC dimming control voltage shall bederived from the ballast, not an externally imposedsource. Dimming shall range from 100% down tono less than 50% of input power. Automatic overtemperature protection shall be provided. Theballast shall carry a warranty of three years wheninstalled in applications meeting the manufacturer’sconditions and the requirements of the applicableUL safety listings.

Dimming option shall include a “Hold High” featurethat maintains full power to lamps when starting upafter loss of power. After a 20 minute delay, thelamp will be restored to its previous dimmedsetting. This is to comply with lamp manufacturerrecommendations regarding starting lamps whiledimmed and the effect on lamp life.

Certain airborne contaminants can diminishthe integrity of acrylic. Please refer to theAcrylic Environmental Compatibility Chart (HL-2445) for suitable uses.

Prismatic Glass Refractor

Acrylic Lens

EN — The Elite Series Electronic BallastMaximum Weight: 20.4 kg (45 lbs.)

EN — Standard Magnetic BallastMaximum Weight: 17.0 kg (38 lbs.)

Page 31: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

HOLOPHANE® | HID LOW BAYS | Enduralume V 31

| INDOOR LIGHTING

Preferred Selections:

Most Frequently Ordered Catalog Numbers

EN1

LUMINAIRE

EN

32PME2

WATTAGE

32PME

V3

VOLTAGE

V

Q4

MOUNTING

Q

85

OPTICS

8

F16

OPTIONS

F1

PF-2917

ACCESSORIES

PF-291

STEP 1: LUMINAIRE

EN Enduralume V

STEP 2: SOURCE AND WATTAGE

HIGH PRESSURE SODIUM250HP 250W HPS400HP 400W HPSEnergy Saving25LHP 250W HPS40LHP 400W HPS

METAL HALIDE175MH 1 175W MH175MP 1 175W MH, protected250MH 1 250W MH250MP 1 250W MH, protected400MH 1 400W MH400MP 1 400W MH, protectedEnergy Saving25LMH 1 250W MH25LMP 1 250W MH, protected40LMH 1 400W MH40LMP 1 400W MH, protected1 Not available for shipment in US after

Dec. 31, 2008, due to EISA legislation

2 Meets US Federal EISA legislation

Catalog Numbers for Entire Product Offering(Pricing and lead times may be affected)

STEP 3: VOLTAGE

08 1 208V12 120V20 208V24 240V27 277V34 347V40 1 240V48 480VV 208, 240, 277 volt Auto

sensing, electronicMulti-voltageMA Prewired for 120VMB Prewired for 208VMC Prewired for 240VMD Prewired for 277VMT Multi-voltageVT 2 Vari-tap

1 Must be handled through TSG2 Available with 250HP, 250MH, 250PM,

25LPM, 320PM, 35LPM, 350PM,400HP, 400MH only

STEP 2: SOURCE (CONTINUED)ELECTRONIC METAL HALIDE32PME 1 320W PMH32PPE 1 320W PMH, protected35PME 1 350W PMH35PPE 1 350W PMH, protected40PME 1 400W PMH40PPE 1 400W PMH, protected

PULSE START METAL HALIDE175PM 2 175W PMH250PM 2 250W PMH250PP 2 250W PMH, protected320PM 2 320W PMH320PP 2 320W PMH, protected350PM 2 350W PMH350PP 2 350W PMH, protected400PM 2 400W PMH400PP 2 400W PMH, protectedEnergy Saving35LPM 2 350W PMH35LPP 2 350W PMH, protected40LPM 2 400W PMH40LPP 2 400W PMH, protected

STEP 4: MOUNTING

N Non quick disconnectpower hanger

P Pendant mount, .75” NPTconduit

Q Quick disconnect powerhanger

STEP 5: OPTICS

7 1 Acrylic lens8 Prismatic glass refractor1 Open rated protected lamp only

STEP 6: OPTIONS

Factory Installed.See page 39 for a complete list of options and product availability

STEP 7: ACCESSORIES

Ships Separately.See page 39 for a complete list ofaccessories and product availability

Page 32: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

32 HOLOPHANE® | HID LOW BAYS | Options and Accessories

HOLOPHANE®

Mounting Options

Options and Accessories

PD - Pendant The separable DN20NPT (.75”) threaded conduit mounting platewith integral set screw shall include a quick install slide onattachment. The housing shall be balanced and suitable for supportfrom hooks or loops. A slide on wireway cover shall enclose thewiring chamber which is suitable for 90° or 105°C building wire.

ND - Non-Disconnect Pendant and Throughway Wiring The die cast aluminum pendant and/or throughway integral wiringbox shall contain provisions for both DN20NPT (.75”) threadedmounting conduit and direct ceiling mounting. It shall contain anintegral hinge connecting the die cast aluminum pin on the housingto support the luminaire while electrical connections are made. Themounting shall have the same corrosion resistant finish as thehousing. The mounting shall consist of 2 cast knockouts, 4 ceilingmount drill points, DN20NPT (.75”) conduit threaded top opening,and be UL/CUL listed and CUL certified for up to five #10 AWGconductors for through wiring. The housing shall swing up andconnect to the ND box by latching the captive J bolt and wing nutwithout use of tools.

QD - Quick-Disconnect Pendant and Throughway Wiring The die cast aluminum pendant and/or throughway quick disconnect wiringbox shall contain provisions for both DN20NPT (.75”) threaded conduitmounting and direct ceiling mounting. It shall contain an integral hingeconnecting the die cast aluminum pin on the housing to allow the luminaireto hang free with electrical disconnect. The mounting shall have the samecorrosion resistant finish as the housing. The mounting shall consist of 2 castknockouts, 4 ceiling mount drill points, DN20NPT (.75”) conduit threaded topopening, and be UL listed for up to five #10 AWG conductors for throughwiring.

The housing shall swing up and connect to the QD box by latching thecaptive J bolt and wing nut without use of tools. A dead front receptacle shallbe mounted inside the QD box which will make an electrical connection withthe pre-wired plug in the housing.

The receptacle shall be UL listed for connection to lighting branch circuitswhich can then be energized before the housing is attached. The groundingconnection shall be the first to make contact and the last to disconnect.

It shall be CUL certified and listed per UL-1059 (Panel Board Accessory) andUL-98 (Enclosed and Dead Front Switches) permitting the luminaire to bedisconnected while under load.

Auxiliary LightingEmergency and standby options providesufficient lighting during failure orinterruptions of the normal power supply.

FusingAccessible fuse protects and isolatesluminaire from circuit. Must specify voltage.

Wire GuardsAll wire guards are made of #10 gaugezinc finished wire form and offer a meansto protect luminaires from minor impact.Wire guards are sold as accessories andshipped separately.

Page 33: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

HOLOPHANE® | HID LOW BAYS | Options and Accessories 33

| INDOOR LIGHTING

Options and Accessories

57mm(2.25”)

LP

PF-129

73mm(2.88”)

67mm(2.63”) 71mm

(2.78”)

92mm(3.62”)

45mm(1.75”)

HK

PF-116 PF-122

PF-291

Thru-way UPH-35 Mounting Detail UPH-35

88mm (.31”) x 10mm (.38”)ceiling mounting (2) places

110mm(4.31”)

130mm(4.94”)

30mm(1.06”)

110mm(4.5”)

Pendant UPH-36

DN20NPT (.75”)threaded entry

22mm (.88”)

(2) wiring accesscovers

(2) KO’s forDN20 (.75”)conduit

120mm(4.88”)

NEMA LOCKING CONFIGURATIONS

Catalog Designation Ampacity Voltage NEMA Configuration Illustration

CDP-L5-15-X 15A 120V L5 - 15

CDP-L6-15-X 15A208V,240V

L6 - 15

CDP-L7-15-X 15A 277V L7 - 15

CDP-L24-20-X 20A 347V L24 - 20

CDP-L8-20-X 20A 480V L8 - 20

Cords, Plugs and ChainsCord and NEMA twist-off plugs for use in areas where support and electrical receptacle is supplied. Most cord and plugs are factory installed and areused typically with hooks or loops (ordered separately). ‘X’ denotes cord length. 3’ is standard and lengths longer than 6’ are handled through TSG.

Hooks, Loops, and Power HooksAll hooks, loops, and power hook and cords assemblies are for use in areas where support and electrical receptacle is supplied. Mounting hooks andloops shall be lubricating cast aluminum or malleable iron and protected against corrosion. Supplied either factory installed or shipped separately.

57mm(2.25”)

73mm(2.88”)

PF-105 PF-121-A

Page 34: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

34 HOLOPHANE® | HID LOW BAYS | Options and Accessories

HOLOPHANE®

Low Profile Series

Luminaire LC Optics LEN Optics LP Optics LK Optics

Housing Heavy duty, cast aluminum ballast housing.

Electrical UL/CUL labeled for damp locations, suitable for ambient temperatures up to 40ºC.

Mounting A variety of mountings including pendant, quick disconnect, and thru-way wiring

Optics The revolutionary ISD SuperGlass® available in wide or narrow light distributions. Enclosed optics offer product components to seal off contaminants

Finish Standard finish for the ballast housing and LEN reflector is white

08214-X Safety chain (3’ is standard)

C3 3’ safety chain

C6 6’ safety chain

C10 10’ safety chain

CD-33’ cord only attached as an option to the electrical assembly. Available with “P” mountingonly. Not available with “MT”

CD-44’ cord only attached as an option to the electrical assembly. Available with “P” mountingonly. Not available with “MT”

CD-6 6’ cord only attached as an option to the electrical assembly. Available with “P” mountingonly. Not available with “MT”

CDP-L5-15-X-PT 120V and MA NEMA 3’, 3 conductor cord and plug. Attached as an option to theelectrical assembly. Order “PF” also. X = length of cord in feet. 3’ is standard.

CDP-L6-15-X-PT 208V, 240V, MB and MC NEMA 3’, 3 conductor cord and plug. Attached as anoption to the electrical assembly. Order “PF” also. X = length of cord in feet. 3’ isstandard.

CDP-L7-15-X-PT 277V and MD NEMA 3’, 3 conductor cord and plug. Attached as an option to the electrical assembly. Order “PF” also. X = length of cord in feet. 3’ is standard.

CDP-L8-20-X-PT 347V NEMA 3’, 3 conductor cord and plug. Attached as an option to the electri-cal assembly. Order “PF” also. X = length of cord in feet. 3’ is standard.

CDP-L24-20-X-PT 480V NEMA 3’, 3 conductor cord and plug. Attached as an option to the electri-cal assembly. Order “PF” also. X = length of cord in feet. 3’ is standard.

ELB Low brightness reflector. Available only on covered optics

EMStandby lighting: 120V tungsten halogen bayonet base lamp and lamp socket to providelighting during times of temporary power interruption until the HID lamp is cool enoughto restrike

ER Emergency circuit lighting: 120V tungsten halogen bayonet base lamp and lamp sockets separate backup (emergency) power circuit that provides sufficient lighting during failureof the normal power supply. Only available with CD, CDP, and PHCB, when handledthrough TSG

F1 Single fuse assembly. (LINE-to-LINE 240/277 volt). Not available with “MT”

F2 Double fuse assembly. (LINE-to-COM 208/240 volt). Order “PF” also. “X” = length ofcord. 3’, 6’, and 10’ is standard. Not available with “MT”

H HALT® Automatic lamp timeout

HK Safety hook, (.75”) male. Available with “P” mount only

LP Loop, (.75”) male. Available with “P” mount only

PHCB Powerhook cord for 120, 208, 240, 277 and 347 volt, MA, MB, MC and MD. Includes PF-105-B. Available with “P” mount only. Not available with “MT”

PHCB-L8-480 Power-hook cord for 480 volt. Available with “P” mount only.

PF-105 Loop, (.75”) male. Available with “P” mount only

PF-121 Safety hook, (.75”) male. Available with “P” mount only

PF-129 2 Anti-rotational hook, (.75”) male. Available with “P” mount only.

PF-291 2 Safety hook (.75”) male. Available with “P” mount only.

PS HPS protected starter. (HPS only)

S Single pack for electrical only

Standard Features, Options and Accessories

Standard - Standard product features, see steps 1-7 on page 11

Option - Product options are factory installed, see step 8 on page 11

Accessory - Product accessory ships separately, see step 9 on page 11

Not Available

S

A

OContact your local sales rep for the most current option and accessory compatibility.

Page 35: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

HOLOPHANE® | HID LOW BAYS | Options and Accessories 35

| INDOOR LIGHTING

Low Profile Series

Luminaire LC Optics LEN Optics LP Optics LK Optics

08214-X Safety chain – X = no. of feet

09274 Wire guard for 6611 optic

09275 Wire guard for 6612 optic

HOOK455 Safety hook, (.75”) male. Available with “P” mounting only.

LAMP Appropriate lamp supplied

LOOP456 Loop, (.75”) male. Available with “P” mounting only.

PF-116-A Loop, (.75”) female. Available with “P” mounting only.

PF-122-A Safety hook, (.75”) female. Available with “P” mounting only.

PF-129-A Anti-rotational hook, (.75”) male. Available with “P” mounting only.

PF-291 Safety hook (.75”) male. Available with “P” mounting only.

PS-55 Protected replacement starter for 15AHP and below

PF-100 Protected replacement starter for 250HP - 400HP only

UPH-35-XXX-WHThru-way power-hook. Available with “P” mounting only. Not available with“ER” or “MT”

UPH-35-L8-480-WH 480V Thru-way power-hook. Available with “P” mounting only.

UPH-36-XXX-WHPendant power-hook. Available with “P” mounting only. Not available with“ER” or “MT”

UPH-36-L8-480-WH 480V Pendant power-hook. Available with “P” mounting only.

WGCG Wire guard for LC optics “AN”, “AW”, “SN” and “SW”

WG-221 Wire guard for LEN optics

Standard - Standard product features, see steps 1-7 on page 11

Option - Product options are factory installed, see step 8 on page 11

Accessory - Product accessory ships separately, see step 9 on page 11

Not Available

S

A

OContact your local sales rep for the most current option and accessory compatibility.

Page 36: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

36 HOLOPHANE® | HID LOW BAYS | Options and Accessories

HOLOPHANE®

Bantam 2000 Series

Luminaire A/C Optics B/G Optics H/K/L/S Optics M/N/U/Z Optics

Housing Heavy duty, cast aluminum ballast housing.

Electrical UL/CUL labeled for damp locations, suitable for ambient temperatures up to 40ºC.

Mounting A variety of mountings including pendant, ceiling, stanchion and wall mount.

Finish Standard finish for the ballast housing and A/C reflector is white

CD-33’ cord only attached as an option to the electrical assembly. Available with “P” mountingonly. Not available with “MT”

CD-44’ cord only attached as an option to the electrical assembly. Available with “P” mountingonly. Not available with “MT”

CD-55’ cord only attached as an option to the electrical assembly. Available with “P” mountingonly. Not available with “MT”

CD-6 6’ cord only attached as an option to the electrical assembly. Available with “P” mountingonly. Not available with “MT”

CDP-L5-15-X-PT 120V and MA NEMA 3’, 3 conductor cord and plug. Attached as an option to theelectrical assembly. Order “PF” also. X = length of cord in feet. 3’ is standard.

CDP-L6-15-X-PT 208V, 240V, MB and MC NEMA 3’, 3 conductor cord and plug. Attached as anoption to the electrical assembly. Order “PF” also. X = length of cord in feet. 3’ isstandard.

CDP-L7-15-X-PT 277V and MD NEMA 3’, 3 conductor cord and plug. Attached as an option to the electrical assembly. Order “PF” also. X = length of cord in feet. 3’ is standard.

CDP-L8-20-X-PT 347V NEMA 3’, 3 conductor cord and plug. Attached as an option to the electri-cal assembly. Order “PF” also. X = length of cord in feet. 3’ is standard.

CDP-L24-20-X-PT 480V NEMA 3’, 3 conductor cord and plug. Attached as an option to the electri-cal assembly. Order “PF” also. X = length of cord in feet. 3’ is standard.

ELB Low brightness reflector. Available only on covered optics

EMStandby lighting: 120V tungsten halogen bayonet base lamp and lamp socket to providelighting during times of temporary power interruption until the HID lamp is cool enoughto restrike

ER Emergency circuit lighting: 120V tungsten halogen bayonet base lamp and lamp sockets separate backup (emergency) power circuit that provides sufficient lighting during failureof the normal power supply. Only available with CD, CDP, and PHCB, when handledthrough TSG

HFW Holoflex® flexible wiring system. Handed through TSG.

HK Safety hook, (.75”) male. Available with “P” mount only

LP Loop, (.75”) male. Available with “P” mount only

PHCB Powerhook cord for 120, 208, 240, 277 and 347 volt, MA, MB, MC and MD. Includes PF-105-B. Available with “P” mount only. Not available with “MT”

PHCB-L8-480 Power-hook cord for 480 volt. Available with “P” mount only.

PF-129 Anti-rotational hook, (.75”) male. Available with “P” mount only.

PF-291 Safety hook (.75”) male. Available with “P” mount only.

PS HPS protected starter. (HPS only)

T NEMA Decal

Standard Features, Options and Accessories

Standard - Standard product features, see steps 1-7 on page 11

Option - Product options are factory installed, see step 8 on page 11

Accessory - Product accessory ships separately, see step 9 on page 11

Not Available

S

A

OContact your local sales rep for the most current option and accessory compatibility.

Page 37: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

HOLOPHANE® | HID LOW BAYS | Options and Accessories 37

| INDOOR LIGHTING

Bantam 2000 Series

Luminaire A/C Optics B/G Optics H/K/L/S Optics M/N/U/Z Optics

0256 Wire guard for Prismalume “H”, “J”, “K” and “L” optics

09189-3 1 Safety chain, 914mm (3’)

09190 Wire guard for Prismatite “B” and “G” refractors

BAS Internal side shield, available with Prismatite “B” and “G” optics only

F1 Single fuse assembly. Ships separately unless factory installed when ordered with CDP orPCHB

F2 Double fuse assembly. Ships separately unless factory installed when ordered with CDP orPCHB

HOOK455 Safety hook, (.75”) male. Available with “P” mounting only.

LAMP Appropriate lamp supplied

LOOP456 Loop, (.75”) male. Available with “P” mounting only.

PF-116-A Loop, (.75”) female. Available with “P” mounting only.

PF-122-A Safety hook, (.75”) female. Available with “P” mounting only.

PF-129-A Anti-rotational hook, (.75”) male. Available with “P” mounting only.

PF-291 Safety hook (.75”) male. Available with “P” mounting only.

UPH-35-XXX-WHThru-way power-hook. Available with “P” mounting only. Not available with“ER” or “MT”

UPH-35-L8-480-WH 480V Thru-way power-hook. Available with “P” mounting only.

UPH-36-XXX-WHPendant power-hook. Available with “P” mounting only. Not available with“ER” or “MT”

UPH-36-L8-480-WH 480V Pendant power-hook. Available with “P” mounting only.

WG-223-A Wire guard for A and C optics only

Standard - Standard product features, see steps 1-7 on page 11

Option - Product options are factory installed, see step 8 on page 11

Accessory - Product accessory ships separately, see step 9 on page 11

Not Available

S

A

OContact your local sales rep for the most current option and accessory compatibility.

Page 38: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

38 HOLOPHANE® | HID LOW BAYS | Options and Accessories

HOLOPHANE®

Lobay V Enduralume V

Luminaire EN ELE

ED Ballast Electronic HID ballast available in 320-400 watt pulse metal halide with “V” auto sensing voltage for 208,240 and 277 voltage.

HID Ballast Standard HID ballast available in 150-400 watt high pressure sodium, metal halide and pulse start metalhalide

Housing Heavy duty, cast aluminum ballast housing.

Electrical UL/CUL labeled for damp locations, suitable for ambient temperatures up to 40ºC.

MountingA variety of mountings including pendant, quick disconnect, and thru-way wiring, as well as Holoflex with a 5’or 6’ cord drop

Finish Standard finish is white for ballast housing and Enduralume reflector

09160-X Safety chain (3’ is standard)

09176 Safety chain (3’ is standard length)

A35AERS® - Automatic Energy Reduction System 35% low mode operation, low voltage AC control.Available with 250HP, 25LHP, 400HP, and 40LHP. Not available with “EM”, “I5A”, “I5R”.“Q”, “CDP”,“EM” or “PHCB”.

A50

AERS® - Automatic Energy Reduction System 50% low mode operation, low voltage AC control.Available 15AHP, 175MP, 250HP, 25LHP, 250MP, 25LMP, 25LPP, 320PP, 350PM, 35LPM, 400HP, 40LHP,400MH, 40LMH, 400PM, 40LPM. Not available with “EM”, “I5A”, “I5R”.“Q”, “CDP”, “EM” or“PHCB”.

CD-3 3’ cord only attached as an option to the electrical assembly (CD-3-PT for ELE)

CD-4 4’ cord only attached as an option to the electrical assembly (CD-4-PT for ELE)

CD-5 5’ cord only attached as an option to the electrical assembly (CD-5-PT for ELE)

CD-6 6’ cord only attached as an option to the electrical assembly. (CD-6-PT for ELE)For lengths longer than 6’handle through TSG.

CDP-L5-15-X-PT 120V and MA NEMA 3’, 3 conductor cord and plug. Attached as an option to the electrical assembly.Order “PF” also. X = length of cord in feet. 3’ is standard.

CDP-L6-15-X-PT 208 and 240V NEMA 3’, 3 conductor cord and plug. Attached as an option to the electrical assembly.Order “PF” also. X = length of cord in feet. 3’ is standard.

CDP-L7-15-X-PT 277V NEMA 3’, 3 conductor cord and plug. Attached as an option to the electrical assembly. Order “PF” also. X = length of cord in feet. 3’ is standard.

CDP-L8-20-X-PT 347V NEMA 3’, 3 conductor cord and plug. Attached as an option to the electrical assembly. Order“PF” also. X = length of cord in feet. 3’ is standard.

CDP-L24-20-X-PT 480V NEMA 3’, 3 conductor cord and plug. Attached as an option to the electrical assembly. Order“PF” also. X = length of cord in feet. 3’ is standard.

CX-UT Safety chain. X = length: 3 = 3’, 6 = 6’, 1 = 10’

D Dimming with terminal block and leads

D35 AERS®- Automatic Energy Reduction System 50% low mode operation, low voltage DC control.Available with 250HP, 25LHP, 400HP, and 40LHP. Not available with “EM”, “I5A” or “I5R”.

D50AERS® - Automatic Energy Reduction System 35% low mode operation, low voltage DC control.Available 15AHP, 175MP, 250HP, 25LHP, 250MP, 25LMP, 25LPP, 320PP, 350PM, 35LPM, 400HP, 40LHP,400MH, 40LMH, 400PM, 40LPM. Not available with “EM”, “I5A” or “I5R”.

EMStandby lighting: 120V tungsten halogen bayonet base lamp and lamp socket to provide lighting duringtimes of temporary power interruption until the HID lamp is cool enough to restrike

ER Emergency circuit lighting: 120V tungsten halogen bayonet base lamp and lamp sockets separate backup (emergency) power circuit that provides sufficient lighting during failure of the normalpower supply

F1 Single fuse assembly. (LINE-to-LINE 240/277 volt)

F2 Double fuse assembly. (LINE-to-COM 208/240 volt)

HK Safety hook, (.75”) male. (Order HK-PT for ELE)

I5A Individually Sensored High Bay, aisle way sensor. Not available with “MT”, or with mogul base units (070HP,170DHP, 15AHP, 175MH/PM)

I5R Individually Sensored High Bay, 360° round sensor. Not available with “MT”, or with mogul base units (070HP,170DHP, 15AHP, 175MH/PM)

Standard Features, Options and Accessories

Standard - Standard product features, see steps 1-7 on page 11

Option - Product options are factory installed, see step 8 on page 11

Accessory - Product accessory ships separately, see step 9 on page 11

Not Available

S

A

OContact your local sales rep for the most current option and accessory compatibility.

Page 39: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

HOLOPHANE® | HID LOW BAYS | Options and Accessories 39

| INDOOR LIGHTING

Lobay V Enduralume V

Luminaire EN ELE

LL Latch lock safety clip

LP Loop, (.75”) male (Order LP-PT for ELE)

PHCBPowerhook cord for 120, 208, 240, 277 and 347 volt, MA, MB, MC and MD. Includes PF-105-B. Available with “P” mount only. Not available with “MT”. (Order PHCB-PT for ELE)

PHCB-L8-480 Power-hook cord for 480 volt. Available with “P” mount only.

PF-129 2 Anti-rotational hook, (.75”) male. Available with “P” mount only.

PF-291 2 Safety hook (.75”) male. Available with “P” mount only.

PS HPS protected starter. (HPS only)

W Wet location. Not available with “ER”, “CDP”, “PHCB”, “F1” or “F2“

HOOK455 Safety hook, (.75”) DN20NPT male

LAMP Appropriate HID lamp

LOOP456 Loop, (.75”) DN20NPT male

PF-105-B Cast malleable iron loop assembly, (.75”) male

PF-116-A Cast malleable iron loop, (.75”) female

PF-121-A Cast malleable iron safety hook assembly, (.75”) male

PF-122-A Safety hook assembly, (.75”) female

PF-129-A Anti-rotational hook, (.75”) male

PF-291 Universal gasketed hook, (.75”) male

PHOTOC Photocell sensor. Must order “D” dimming option

UPH-35-XXX-WH Thru-way power-hook. Available with “P” mounting only. Not available with “ER” or “MT”

UPH-35-L8-480-WH 480V Thru-way power-hook. Available with “P” mounting only.

UPH-36-XXX-WH Pendant power-hook. Available with “P” mounting only. Not available with “ER” or “MT”

UPH-36-L8-480-WH 480V Pendant power-hook. Available with “P” mounting only.

WG-221 Wire guard for optics

Standard - Standard product features, see steps 1-7 on page 11

Option - Product options are factory installed, see step 8 on page 11

Accessory - Product accessory ships separately, see step 9 on page 11

Not Available

S

A

OContact your local sales rep for the most current option and accessory compatibility.

Page 40: HID Low bays - · PDF fileHID Low bays Product Catalog. 2 ... LK Low Profile Prismpack LP Low Profile Prismalume STEP 2: SOURCE AND WATTAGE HIGH PRESSURE SODIUM ... Spun Aluminum Cover

Acuity Brands Lighting, Inc.

Holophane Headquarters, 3825 Columbus Road,Granville, OH 43023Holophane Canada, Inc. 9040 Leslie Street, Suite 208, Richmond Hill, ON L4B 3M4Holophane Europe Limited, Bond Ave., Milton Keynes MK1 1JG, EnglandHolophane, S.A. de C.V., Apartado Postal No. 986,Naucalpan de Juarez, 53000 Edo. de Mexico

Contact your local Holophane factory salesrepresentative for application assistance, andcomputer-aided design and cost studies. For information on other Holophane products and systems, call the Inside Sales Service Department at 740-345-9631. In Canada call 905-707-5830or fax 905-707-5695.

Limited Warranty and Limitation of LiabilityRefer to the Holophane limited material warrantyand limitation of liability on this product, whichare published in the “Terms and Conditions”section of the current Buyers Guide, and isavailable from your local Holophane sales representative.

Visit our web site at www.holophane.com

HL-2426 8/09 ©2009 Acuity Brands Lighting, Inc Printed in USA

Luminaires may utilize fluorescent or high intensitydischarge sources that contain small amounts of

mercury. New disposal labeling for theselamps includes the mercury identifiershown on the left to indicate that thelamp contains mercury and should be

disposed of in accordance with local requirements.

Information sources regarding lamp recycling anddisposal are included on the packaging of mostmercury-containing lamps and also can be located at www.lamprecycle.org.

Product specifications may change without notice. Please contact your local Holophane factory sales representative for the latest product information.

10%

Buying products with the FSC label supports the growth of responsible forest managementworldwide. The eco savings in the production of this brochure:

4 trees preserved for the future

1,672 gallons wastewater flow saved

101 lbs solid waste not generated

347 lbs net greenhouse gases prevented

1,000,000 BTUs energy not consumed