HES-HKS & KaoS meeting
description
Transcript of HES-HKS & KaoS meeting
HES-HKS & KaoS meeting14/Oct/2011Toshi Gogami
25/May/2011, A-1 Counting Room, Mainz Univ.
Contents
• Rate of KDC
For the whole acceptance of the HKS
The HKS Tracking efficiencies(The Difference between Low & high momentum side)
Momentum dependence Mesh study
77124 ( 52Cr target )
5 × 5
覚書 for me
1. Pick up information from “h_dc_trans.f”– Total hits, Raw TDC, Plane, Wire– Output “kdc_WireRate.dat”
2. e05115replay/kdcrate/*– Create ROOT file from dat file (mkROOT)– ./root/*.root• ratelayer.cc• ratewire.cc
Rates of the KDC LayersCH2, 76314
KDC1 KDC2~3 MHz~6 MHz
Rates of the KDC LayersH2O, 75971
KDC1 KDC2~10 MHz~20 MHz
Rates of the KDC Layers52Cr, 76314
KDC1 KDC2~11 MHz~22 MHz
Rates of the KDC wiresCH2, 76314
Wire Number
Rate
[kH
z]
KDC1-u KDC1-u’ KDC1-x KDC1-x’ KDC1-v KDC1-v’
KDC2-u KDC2-u’ KDC2-x KDC2-x’ KDC2-v KDC2-v’
< 150 kHz < 120 kHz
< 70 kHz < 60 kHz
Rates of the KDC wiresH2O, 75971
Wire Number
Rate
[kH
z]
KDC1-u KDC1-u’ KDC1-x KDC1-x’ KDC1-v KDC1-v’
KDC2-u KDC2-u’ KDC2-x KDC2-x’ KDC2-v KDC2-v’
< 450 kHz < 270 kHz
< 250 kHz < 200 kHz
Rates of the KDC wires52Cr, 77124
Wire Number
Rate
[kH
z]
KDC1-u KDC1-u’ KDC1-x KDC1-x’ KDC1-v KDC1-v’
KDC2-u KDC2-u’ KDC2-x KDC2-x’ KDC2-v KDC2-v’
< 510 kHz < 350 kHz
< 290 kHz < 230 kHz
Summary and To do
• Summary– Rate per KDC layers
• KDC1 < 25MHz, KDC2 < 15MHz (for 52Cr data)
– Rate per KDC wires• KDC1 < ~500 [kHz] (u-layer), KDC2 < ~300 [kHz] (u-layer) (for 52Cr data)
• To Do– E01-011
• Enge GEANT
– E05-115• Momentum dependence of the HKS tracking efficiency• HKS b.g. rate study by GEANT simulation• Miss identification efficiency estimation by Doi code
End1/Oct/2011, Venezia, Italy
A effect of the new tracking code(HKS single analysis)
A pure effect of the improvement of the tracking code• All entries 71.1% increased• Kaons 75.5% increased
Improved uniformly for the HKS acceptance
77120 – 77124 (52Cr target)
After
Before