HELUTHERM ® 145 flexible, cross-linked, halogen-free Properties Cable structure Technical data Tinned copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 Halogen-free single cores with increased heat resistance Lower propagation of fire Low development of smoke and fumes • Temperature range flexing -35°C to +120°C fixed installation -55°C to +145°C Good abrasion and notch resistance Core insulation of polyolefin-copolymer cross-linked and halogen-free Good resistance to oils and weathering Resistant to UV radiation and ozone Core identification, see table below • Nominal voltage up to 1 mm² = U0/U 300/500 V from 1,5 mm² = U0/U 450/ 750 V at fixed and protected installation from 1,5 mm² = U0/U 600/1000 V Resistant to soldering temperatures Tests Thermal class B Flame test (unit flame test) acc. to DIN VDE 0482-332-3-22, BS 4066 Teil 3, DIN EN 60332-3-22, IEC 60332-3-22 (previously DIN VDE 0472 part 804 test method C) These single-core cables are resistant to melting, even when in contact with a soldering iron at temperatures of between 300°C and 380°C, because of the cross-linking for the insulation material • Test voltage 3500 V Flame test (cable) acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) • Minimum bending radius flexing 12,5x core Ø fixed installation 4x core Ø Due to the high temperature profile the cross section of conductor can under certain circumstances be reduced, hereby enabling a saving in space requirement and weight • Caloric load values see "Technical Informations" Corrosiveness of combustion gases acc. to DIN VDE 0482 part 267, DIN EN 50267-2-2, IEC 60754-2 (equivalent DIN VDE 0472 part 813) The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers • Approval Germanischer Lloyd Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815) Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816) Application These temperature resistant single-core cables are used for the internal wiring of lighting fixtures, heaters, electrical machinery, switching systems and distributors in equipment and plant and machinery, suitable for laying in tubes on and under plaster, in closed installation ducts, as well as for traffic systems and outdoor applications. These cables are not approved for direct routing on racks, gutters or tanks. These halogen-free single core cables are characterised by their amazingly high long-time resistance to temperature and feature among the leading halogen-free, flame resistant products in the world. These single core cables significantly contribute to safety and the environment. = Product conforms with Low-Voltage Directive 2014/35/EU. Weight app. kg / km Cop. weight kg / km Outer Ø app. mm Cross- sec. mm² 2-col. BEIGE OG D-BU GN YE VT GY WH RD BN BU GN-YE BK 51165 51164 51077 51079 51078 51076 51075 51074 51073 51072 51071 51070 50998 50999 Part no. 4,0 2,4 1,6 0,25 51179 51178 51175 51177 51176 51174 51173 51172 51171 51170 51169 51168 51166 51167 Part no. 5,0 3,2 1,7 0,34 51293 51292 51289 51291 51290 51288 51287 51286 51285 51284 51283 51282 51280 51281 Part no. 7,0 4,8 1,9 0,5 51307 51306 51303 51305 51304 51302 51301 51300 51299 51298 51297 51296 51294 51295 Part no. 11,0 7,2 2,2 0,75 51321 51320 51317 51319 51318 51316 51315 51314 51313 51312 51311 51310 51308 51309 Part no. 14,0 9,6 2,5 1 51335 51334 51331 51333 51332 51330 51329 51328 51327 51326 51325 51324 51322 51323 Part no. 20,0 14,4 2,9 1,5 51349 51348 51345 51347 51346 51344 51343 51342 51341 51340 51339 51338 51336 51337 Part no. 30,0 24,0 3,5 2,5 51363 51362 51359 51361 51360 51358 51357 51356 51355 51354 51353 51352 51350 51351 Part no. 47,0 38,0 4,3 4 51377 51376 51373 51375 51374 51372 51371 51370 51369 51368 51367 51366 51364 51365 Part no. 72,0 58,0 5,0 6 51391 51390 51387 51389 51388 51386 51385 51384 51383 51382 51381 51380 51378 51379 Part no. 120,0 96,0 6,3 10 Continuation 27.09.2016 / Dimensions and specifications may be changed without prior notice.

Transcript of HELUTHERM 145 - asset.conrad.com

Page 1: HELUTHERM 145 - asset.conrad.com

HELUTHERM® 145flexible, cross-linked, halogen-free 

 

PropertiesCable structureTechnical data• Tinned copper conductor, toDIN VDE 0295 cl.5, fine wire,BS 6360 cl.5, IEC 60228 cl.5

• •Halogen-free single cores with increasedheat resistance

Lower propagation of fire• Low development of smoke and fumes

• Temperature rangeflexing -35°C to +120°Cfixed installation -55°C to +145°C

• Good abrasion and notch resistance• Core insulation of polyolefin-copolymercross-linked and halogen-free

• Good resistance to oils and weathering• Resistant to UV radiation and ozone

• Core identification, see table below• Nominal voltageup to 1 mm² = U0/U 300/500 Vfrom 1,5 mm² = U0/U 450/ 750 Vat fixed and protected installationfrom 1,5 mm² = U0/U 600/1000 V

• Resistant to soldering temperaturesTests • Thermal class B• Flame test (unit flame test) acc. toDIN VDE 0482-332-3-22, BS 4066 Teil 3,DIN EN 60332-3-22, IEC 60332-3-22(previously DIN VDE 0472part 804 test method C)

• These single-core cables are resistant tomelting, even when in contact with asoldering iron at temperatures of between300°C and 380°C, because of thecross-linking for the insulation material

• Test voltage3500 V

• Flame test (cable) acc. toDIN VDE 0482-332-1-2, DIN EN 60332-1-2,IEC 60332-1-2 (equivalent DIN VDE 0472part 804 test method B)

• Minimum bending radiusflexing 12,5x core Øfixed installation 4x core Ø

• Due to the high temperature profile thecross section of conductor can under certaincircumstances be reduced, hereby enablinga saving in space requirement and weight• Caloric load values

see "Technical Informations" • Corrosiveness of combustion gasesacc. to DIN VDE 0482 part 267,DIN EN 50267-2-2, IEC 60754-2(equivalent DIN VDE 0472 part 813)

• The materials used during manufacturingare cadmium-free, contain no siliconeand are free from substances harmfulto the wetting properties of lacquers

• ApprovalGermanischer Lloyd

• Halogen-free acc. to DIN VDE 0482 part 267,DIN EN 50267-2-1, IEC 60754-1(equivalent DIN VDE 0472 part 815)

• Smoke density acc. to DIN VDE 0482part 1034-1+2, DIN EN 61034-1+2,IEC 61034-1+2, BS 7622 part 1+2(previously DIN VDE 0472 part 816)

 

ApplicationThese temperature resistant single-core cables are used for the internal wiring of lighting fixtures, heaters, electrical machinery, switching systemsand distributors in equipment and plant and machinery, suitable for laying in tubes on and under plaster, in closed installation ducts, as well as fortraffic systems and outdoor applications. These cables are not approved for direct routing on racks, gutters or tanks. These halogen-free single corecables are characterised by their amazingly high long-time resistance to temperature and feature among the leading halogen-free, flame resistantproducts in the world. These single core cables significantly contribute to safety and the environment.= Product conforms with Low-Voltage Directive 2014/35/EU.

 

 Weightapp.kg / km

Cop.weightkg / km

Outer Øapp. mm

Cross-sec.mm²

2-col.BEIGEOGD-BUGNYEVTGYWHRDBNBUGN-YEBK

5116551164510775107951078510765107551074510735107251071510705099850999Part no.4,02,41,60,25

5117951178511755117751176511745117351172511715117051169511685116651167Part no.5,03,21,70,34

5129351292512895129151290512885128751286512855128451283512825128051281Part no.7,04,81,90,5

5130751306513035130551304513025130151300512995129851297512965129451295Part no.11,07,22,20,75

5132151320513175131951318513165131551314513135131251311513105130851309Part no.14,09,62,51

5133551334513315133351332513305132951328513275132651325513245132251323Part no.20,014,42,91,5

5134951348513455134751346513445134351342513415134051339513385133651337Part no.30,024,03,52,5

5136351362513595136151360513585135751356513555135451353513525135051351Part no.47,038,04,34

5137751376513735137551374513725137151370513695136851367513665136451365Part no.72,058,05,06

5139151390513875138951388513865138551384513835138251381513805137851379Part no.120,096,06,310

 

Continuation 

27.09.2016 / Dimensions and specifications may be changed without prior notice.

Page 2: HELUTHERM 145 - asset.conrad.com

HELUTHERM® 145flexible, cross-linked, halogen-free 

Weightapp.kg / km

Cop.weightkg / km

Outer Øapp. mm

Cross-sec.mm²

2-col.BEIGEOGD-BUGNYEVTGYWHRDBNBUGN-YEBK

5143251431514285143051429514275142651425514245142351422514215141951420Part no.182,0154,07,316

5144651445514425144451443514415144051439514385143751436514355143351434Part no.272,0240,09,625

5146051459514565145851457514555145451453514525145151450514495144751448Part no.371,0336,010,835

5147451473514705147251471514695146851467514665146551464514635146151462Part no.530,0480,012,650

5148851487514845148651485514835148251481514805147951478514775147551476Part no.730,0672,014,670

5150251501514985150051499514975149651495514945149351492514915148951490Part no.964,0912,016,595

5151651515515125151451513515115151051509515085150751506515055150351504Part no.1235,01152,018,0120

5153051529515265152851527515255152451523515225152151520515195151751518Part no.1523,01440,020,0150

5154451543515405154251541515395153851537515365153551534515335153151532Part no.1850,01776,022,2185

5155851557515545155651555515535155251551515505154951548515475154551546Part no.2432,02304,024,5240

 

Dimensions and specifications may be changed without prior notice. (RK01)