HELIO SINGLE LEVER LAVATORY FAUCET TX108LH · "HELIO" SINGLE LEVER LAVATORY FAUCET TX108LH S06509B...

1
SPECIFICATIONS OPERATING CONDITIONS TROUBLESHOOTING INSTALLATION Water supply pressure : 0.05 ~ 0.75 MPa Ensure that water supply is clean ( No Sand, Dirt, Etc.). 1. 2. 1. AERATOR 3. BOLT "HELIO" SINGLE LEVER LAVATORY FAUCET TX108LH S06509B 2. CONNECTING NUT CHECK POINT Flow rate unsatisfactory 1, 5 Remove and clean Water leaks around the handle 2 Tighten Handle is loose 3 Tighten Plug cannot open and close 4 Tighten PROBLEM SOLUTION 4. BOLT TX108LHBR "HELIO" Single Lever Lavatory Faucet w/ 1¼" Pop-Up Waste 107 48 26° 119 317 max.30 TX108LHV1BR "HELIO" Single Lever Lavatory Faucet w/o Pop- Up Waste Plug Packing Triangle Packing Pivot Rod Nut Siphon Kick Box Bolt Pop-Up Clip Bolt 1. 3. TX108LHV2BR "HELIO" Single Lever Lavatory Faucet w/ 1¼" Pop-Up Waste & Flow Restrictor TX108LHV5BR "HELIO" Single Lever Lavatory Faucet w/o Pop- Up Waste w/ Flow Restrictor 5. FLOW RESTRICTOR ( Only for TX108LHV2BR & TX108LHV5BR) ATTENTION Setting Bolt Washer Setting Nut Packing Lift Rod Faucet MAINTENANCE Always wipe chrome plated area with dry soft cloth, and sometimes wipe it with cloth soaked in mild soap. Clean the Flow restrictor periodically with soft brush 1. 2. Flow Restrictor Flow Restrictor House Use of abrasive cleaning material such as; detergents containing hydrochloric acids, thinner, polishing powder, and nylon brush is not recommended. Washer R3 2. Packing To Hot Water Supply To Cold Water Supply Ø35 Hole 107 48 26° 119 317 max.30 107 48 26° 119 317 max.30 107 48 26° 119 317 max.30

Transcript of HELIO SINGLE LEVER LAVATORY FAUCET TX108LH · "HELIO" SINGLE LEVER LAVATORY FAUCET TX108LH S06509B...

Page 1: HELIO SINGLE LEVER LAVATORY FAUCET TX108LH · "HELIO" SINGLE LEVER LAVATORY FAUCET TX108LH S06509B 2. CONNECTING NUT CHECK POINT Flow rate unsatisfactory 1, 5 Remove and clean Water

SPECIFICATIONS

OPERATING CONDITIONS

TROUBLESHOOTINGINSTALLATION

Water supply pressure : 0.05 ~ 0.75 MPaEnsure that water supply is clean ( No Sand, Dirt, Etc.).

1.2.

1. AERATOR

3. BOLT

"HELIO" SINGLE LEVER LAVATORY FAUCET TX108LH

S06509B

2. CONNECTING NUT

CHECKPOINT

Flow rate unsatisfactory 1, 5 Remove and cleanWater leaks around the handle 2 TightenHandle is loose 3 TightenPlug cannot open and close 4 Tighten

PROBLEM SOLUTION

4. BOLT

TX108LHBR"HELIO" Single Lever Lavatory Faucet w/ 1¼"

Pop-Up Waste

107

48

26°

119

317

max.30

TX108LHV1BR"HELIO" Single Lever Lavatory Faucet w/o Pop-

Up WastePlug

PackingTriangle Packing

Pivot Rod

Nut

Siphon

Kick Box

Bolt

Pop-UpClip

Bolt

1.

3.TX108LHV2BR

"HELIO" Single Lever Lavatory Faucet w/ 1¼" Pop-Up Waste & Flow Restrictor

TX108LHV5BR"HELIO" Single Lever Lavatory Faucet w/o Pop-

Up Waste w/ Flow Restrictor

5. FLOW RESTRICTOR ( Only for TX108LHV2BR & TX108LHV5BR)

ATTENTION

Setting Bolt

Washer

Setting Nut

Packing

Lift Rod

Faucet

MAINTENANCEAlways wipe chrome plated area with dry soft cloth, and sometimes wipe it with cloth soaked in mild soap.Clean the Flow restrictor periodically with soft brush

1.

2.

Flow Restrictor

Flow RestrictorHouse

Use of abrasive cleaning material such as; detergents containing hydrochloric acids, thinner, polishing powder, and nylon brush is not recommended.

Washer

R3

2.

Packing

To HotWater Supply To Cold

Water Supply

Ø35 Hole107

48

26°

119

317

max.30

107

48

26°

119

317

max.30

107

48

26°

119

317

max.30