HeatPro Series Room...Water Temperature up to 60 oC Thanks to EVI technology, HeatPro Series...

2
GUANGDONG PHNIX ECO-ENERGY SOLUTION LTD. TEL: +86-4009-4009-00 FAX: +86-20-39067770 E-mail: [email protected] Website: www.phnix-e.com For House Heating/Cooling, Sanitary Hot Water dB(A) / / / mm m3/h °C / A kg Noise Hitachi R410A EVI Rotary PHNIX Patented Tube in Shell Heat Exchanger R410A/3.0kg Copeland R410A EVI Scroll Cooling Capacity(kW) Power Input(kW) EER(W/W) Hot Water(L/h) Heating Capacity(kW) Power Input(kW) COP(W/W) Heating Capacity(kW) Power Input(kW) COP(W/W) Heating Capacity(kW) Power Input(kW) COP(W/W) 63 35.7 2 1.65 5 1000/415/1315 150 4.2 2.58 10.8 400 4.1 18.6 4.54 13.8 5.4 3.6 4.14 2.56 14.9 71 37.0 1 8.5 5 1413/845/2000 475 10.6 2.58 27.3 1075 10.8 50.0 4.63 43.0 14.5 10.0 4.20 2.97 42.0 65 19.0 2 5.2 5 1556/605/1850 331 7.5 2.40 18.0 800 7.8 36.5 4.67 31.4 10.6 7.4 4.20 2.96 31.1 63 13 2 1.65 5 1000/415/1315 140 3.9 2.9 11.3 398 4.0 18.5 4.63 14.6 5.0 3.3 4.76 2.92 15.7 64 46.4 2 2.6 5 1175/400/1588 208 7.6 1.89 14.4 585 6.9 27.2 3.94 22.6 8.9 5.9 4.14 2.54 24.4 64 18.7 2 2.6 5 1175/400/1588 215 7.0 2.54 17.8 585 6.6 27.2 4.12 22.6 8.9 5.8 4.21 2.54 24.4 73 74.0 2 17 5 2180/1080/2100 778 21.9 2.69 59.0 2150 22.0 100.0 4.55 86.0 29.0 20.0 4.20 2.97 84.0 Copeland R410A EVI Scroll Power Supply Net Weight Operation Range Water Flow Volume Maximum Outlet Water Temp. Water Pressure Drop Air Discharge Type Compressor Type Fan Motor Power Input Compressor Quantity Refrigerant Type / Quantity Water Connection Suggested Water Temp Differential. Maximum Power Input Shipping Dimensions(L/W/H) Net Dimensions(L/W/H) Condenser Fan Quantity Maximum Current Cooling Condition A35°C/24°C, W12°C/7°C Hot Water Condition A20°C/15°C, W15°C to 55°C *Heating Condition A7°C/6°C, W50°C/ 55°C **Heating Condition A7°C/6°C, W30°C/ 35°C Gross Weight / Vertical Horizontal °C -25~45 -30~45 °C 60 kg 162 500 366 152 222 229 843 mm 1080/445/1470 1490/900/2160 1630/700/2010 1080/445/1470 1200/450/1600 1200/450/1600 2260/1130/2260 kPa 29.0 60.0 53.0 29.0 29.6 29.6 65.0 W 85 x 2 1100 x 1 300 x 2 85 x 2 110 x 2 110 x 2 1100 x 2 / 1 1 2 1 2 2 2 / 200-240V~/50Hz 380-415V/3N~/50Hz 200-240V~/50Hz 380-415V/3N~/50Hz HeatPro Series Air to Water Heat Pump Parameter KV15A KV45T KV30T KV15T KV24 KV24T KV90T Model kW 7.9 20.8 12.0 7.9 10.2 10.2 41.5 inch 1.25 2 1.5 1.25 1.5 1.5 3 R410A/3.0kg R410A/2.2kg×2 R410A/2.6kg×2 R410A/7.5kg R410A/9.0kg R410A/9.0kg×2

Transcript of HeatPro Series Room...Water Temperature up to 60 oC Thanks to EVI technology, HeatPro Series...

Page 1: HeatPro Series Room...Water Temperature up to 60 oC Thanks to EVI technology, HeatPro Series features a wide operating temperature range. It means they can reach high water temperature

GUANGDONG PHNIX ECO-ENERGY SOLUTION LTD.TEL: +86-4009-4009-00 FAX: +86-20-39067770 E-mail: [email protected] Website: www.phnix-e.com

For House Heating/Cooling, Sanitary

Hot Water

dB(A)

/

/

/

mm

m3/h

°C

/

A

kg

Noise

Hitachi R410A EVI Rotary

PHNIX Patented Tube in Shell Heat Exchanger

R410A/3.0kg

Copeland R410A EVI Scroll

Cooling Capacity(kW)

Power Input(kW)

EER(W/W)

Hot Water(L/h)

Heating Capacity(kW)

Power Input(kW)

COP(W/W)

Heating Capacity(kW)

Power Input(kW)

COP(W/W)

Heating Capacity(kW)

Power Input(kW)

COP(W/W)

63

35.7

2

1.65

5

1000/415/1315

150

4.2

2.58

10.8

400

4.1

18.6

4.54

13.8

5.4

3.6

4.14

2.56

14.9

71

37.0

1

8.5

5

1413/845/2000

475

10.6

2.58

27.3

1075

10.8

50.0

4.63

43.0

14.5

10.0

4.20

2.97

42.0

65

19.0

2

5.2

5

1556/605/1850

331

7.5

2.40

18.0

800

7.8

36.5

4.67

31.4

10.6

7.4

4.20

2.96

31.1

63

13

2

1.65

5

1000/415/1315

140

3.9

2.9

11.3

398

4.0

18.5

4.63

14.6

5.0

3.3

4.76

2.92

15.7

64

46.4

2

2.6

5

1175/400/1588

208

7.6

1.89

14.4

585

6.9

27.2

3.94

22.6

8.9

5.9

4.14

2.54

24.4

64

18.7

2

2.6

5

1175/400/1588

215

7.0

2.54

17.8

585

6.6

27.2

4.12

22.6

8.9

5.8

4.21

2.54

24.4

73

74.0

2

17

5

2180/1080/2100

778

21.9

2.69

59.0

2150

22.0

100.0

4.55

86.0

29.0

20.0

4.20

2.97

84.0

Copeland R410A EVI Scroll

Power Supply

Net Weight

Operation Range

Water Flow Volume

Maximum Outlet Water Temp.

Water Pressure Drop

Air Discharge Type

Compressor Type

Fan Motor Power Input

Compressor Quantity

Refrigerant Type / Quantity

Water Connection

Suggested Water Temp Di�erential.

Maximum Power Input

Shipping Dimensions(L/W/H)

Net Dimensions(L/W/H)

Condenser

Fan Quantity

Maximum Current

Cooling Condition

A35°C/24°C, W12°C/7°C

Hot Water Condition

A20°C/15°C, W15°C to 55°C

*Heating Condition

A7°C/6°C, W50°C/ 55°C

**Heating Condition

A7°C/6°C, W30°C/ 35°C

Gross Weight

/ VerticalHorizontal

°C -25~45 -30~45

°C 60

kg 162 500366152 222 229 843

mm 1080/445/1470 1490/900/21601630/700/20101080/445/1470 1200/450/1600 1200/450/1600 2260/1130/2260

kPa 29.0 60.053.029.0 29.6 29.6 65.0

W 85 x 2 1100 x 1300 x 285 x 2 110 x 2 110 x 2 1100 x 2

/ 1 121 2 2 2

/ 200-240V~/50Hz 380-415V/3N~/50Hz 200-240V~/50Hz 380-415V/3N~/50Hz

HeatPro SeriesAir to Water Heat Pump

ParameterKV15A KV45TKV30TKV15T KV24 KV24T KV90TModel

kW 7.9 20.812.07.9 10.2 10.2 41.5

inch 1.25 21.51.25 1.5 1.5 3

R410A/3.0kg R410A/2.2kg×2 R410A/2.6kg×2 R410A/7.5kg R410A/9.0kg R410A/9.0kg×2

Page 2: HeatPro Series Room...Water Temperature up to 60 oC Thanks to EVI technology, HeatPro Series features a wide operating temperature range. It means they can reach high water temperature

Water Temperature up to 60 oC Thanks to EVI technology, HeatPro Series features a wide operating temperature range. It means they can reach high water temperature (55-60oC)

even in cold climate ranging from -20oC to 45oC, and can work safely and reliably at ambient temperature as low as -30oC with Wet Injection

technology.

Outlet Water Temperature(oC)

HeatPro Series Heat Pumps Normal Heat Pumps

Ambient Temperature(oC)

-25 0 5 10 15 20 25 30-30 35-20 -15 -10 -5

15

45

556065

105

20

303540

50

25

40 45

Residential Hot Water/Heating/Cooling

Apartments, villas, hotels

• Axial and radial compliance for

high reliability

• 25% further heating capacity &

10% higher heating COP with

EVI technology

SUPERHEAT MANAGEMENT

• Increased heating capacity and

extended operation life with TEV

• Increased COP and limited

discharge temperature under safe

level with EEV

• Less deforsting time and more

energy-saving

R410A EVI

HEAT EXCHANGER

• No freezing off even powered off for 20hs

at -30oC air temperature

• PHNIX patented heat exchanger for R410A

• Overall insulation with low heat loss

PHNIX Heat Pump Technology Wide Applications

Wide Applications

HeatPro Series Air to Water Heat Pump