Heating Cables...FATI power connection, splice, tee and end seal kit will reduce installation time....
Transcript of Heating Cables...FATI power connection, splice, tee and end seal kit will reduce installation time....
Inner insulation
Self-regulating semi-conductive core
Tinned copper braid
Tinned copper buswires16 AWG
Optional outer jacket
Features
· Energy efficient, automatically varies its power output in response to pipe temperature changes. · Easy to install, can be cut to any length (up to 125 meters) required on site with no wasted cable. · Lower installed cost than steam tracing, less maintenance expense and less downtime. · No overheat or burnout even when wrapped over itself (overlapped). · Suitable for use in non-hazardous, hazardous and corrosive environments. · FATI power connection, splice, tee and end seal kit will reduce installation time. · Optional outer jacket, the heating cable is resistant to watery and inorganic chemicals and corrosive.
Option
·FFHT-X…C Tinned copper or stainless steel braid provide additional mechanical protection and a positive groundpath. ·FFHT-X…CG High Temperature Fluoropolymer overjacket are used for exposure to organic or corrosive solutions or vapors may be present.
FFHT-X
Self Regulating Heating Cable
Application
FFHT-X is an industrial grade, ATEX approved self-regulating parallel heating cable (heating tape) manufactured in accordance to BS6351 Grade 22, that can be used for applications ranging from process heating or maintenance of temperature up to 120℃. It can be used in hazardous and non-hazardous locations, including areas where corrosives may be present.
FATI-FFHT-X · 1/2
Technical data
Service voltage 110V/230V
Maximum maintain temperature(power on) +120℃ (250℉)
Maximum exposure temperature (power off) +200℃ (390℉)
Minimum installation temperature -40℃ (-40℉)
Protective braid resistance ﹤18.2Ω/km
Bus wire gauge 16 AWG
Approvals EPT 16 ATEX 2551 X
0
10
20
30
40
0 10 20 30 40 50 60 70 80 90 100 110 120
W/m
°C
FATI-FFHT-X · 2/2
FFHT-X
Self Regulating Heating Cable
Dimension and weight
Product ordering information Power output curvesNominal power output at 230V when FFHT-X is installed on insulated pipes.
Type Dimension Min.bending radius
Weight (kg/100m)
FFHT-X…C 9.3×4.4mm 26mm 9.7
FFHT-X…CT 10.3×5.4mm 32mm 9.5
B
For example: FFHT-X-15.2-CG
Outer jacketG=FluorpolymerTinned Copper BraidSupply Voltage1=110-120VAC; 2=220-277VAC
Power in W/m at +5°C15=15W/m; 30=30W/m
Type of cable
30FFHT-X
15FFHT-X
Start-up Temperature
Circuit Breaker Size
230V
120V
230V
120V
48
25
65
33
–40°
C
16A
72
36
100
50
–20°
C
85
43
120
60
–10°
C
110
55
155
78
10° C
66
34
85
43
–40°
C
20A
92
46
132
66
–20°
C
105
53
145
73
–10°
C
125
63
160
80
10° C
80
40
110
55
–40°
C
25A
115
58
160
80
–20°
C
120
60
160
80
–10°
C
125
63
160
80
10° C
98
50
140
70
–40°
C
32A
125
63
160
80
–20°
C
125
63
160
80
–10°
C
125
63
160
80
10° C
0
10
20
30
40
0 10 20 30 40 50 60 70 80 90100110120
°CPipe temperature °C
A 15FFHT-XB 30FFHT-X
A
F.A.T.I. Via A. Volta, 52 · 20090 Cusago (MI) [email protected] · www.fati.com
Maximum length (m) vs. circuit breaker size
W/m
FFHT-X -C
Inner insulation
Features
· Energy efficient, automatically varies its power output in response to pipe temperature changes. · Easy to install, can be cut to any length (up to 125 meters) required on site with no wasted cable. · Lower installed cost than steam tracing, less maintenance expense and less downtime. · No overheat or burnout even when wrapped over itself (overlapped). · Suitable for use in non-hazardous, hazardous and corrosive environments. · FATI power connection, splice, tee and end seal kit will reduce installation time. · Optional outer jacket, the heating cable is resistant to watery and inorganic chemicals and corrosive.
Option ·FFBT-X…C Tinned copper braid provide additional mechanical protection and a positive groundpath. ·FFBT-X…CG High Temperature Fluoropolymer overjacket are used for installationin hazardous location or where corrosive solutions or vapors may be present.
FFBT -X
Self Regulating Heating Cable
Application
FFTB-X is an industrial grade, ATEX approved self-regulating parallel heating cable (heating tape) manufactured in accordance to BS6351 Grade 22, that can be used for applications ranging from process heating or maintenance of temperature up to 65℃. It can be used in hazardous and non-hazardous locations, including areas where corrosives may be present.
FATI-FFBT-X · 1/2
Technical data
Service voltage 110V/230V
Maximum maintain or continuous exposuretemperature (power on)
+65℃ (149℉)
Maximum intermittent exposure temperature 1000 hours (power on or off)
+75℃ (167℉)
Minimum installation temperature -40℃ (-40℉)
Protective braid resistance ﹤18.2Ω/km
Bus wire gauge 16 AWG
Approvals EPT 16 ATEX 2551 X
Self-regulating semi-conductive core
Tinned copper braid
Tinned copper buswires16 AWG
Optional outer jacket
0
10
20
30
0 10 20 30 40 50 60 70
W/m
FATI-FFBT-X · 2/2
Dimension and weight
Product ordering information Power output curvesNominal power output at 230V when FFBT-X is installed on insulated pipes.
Type Dimension Min.bending radius
Weight (kg/100m)
FFBT-X…C 9.3×4.4mm 26mm 9.7
FFBT-X…CT 10.3×5.4mm 32mm 9.5
B
A
FFBT-X -C For example: FFBT-X-15.2-CG
Outer jacketG=FluoropolymerTinned Copper BraidSupply Voltage1=110-120VAC; 2=220-277VAC
Power in W/m at +5°C15=15W/m; 26=26W/m
Type of cable
FFBT-X
Self Regulating Heating Cable
Maximum length (m) vs. circuit breaker size
26FFBT-X
15FFBT-X
Start-up Temperature
Circuit Breaker Size
230V
120V
230V
120V
48
25
65
33
–40°
C
16A
72
36
100
50
–20°
C
85
43
120
60
–10°
C
110
55
155
78
10° C
66
34
85
43
–40°
C
20A
92
46
132
66
–20°
C
105
53
145
73
–10°
C
125
63
160
80
10° C
80
40
110
55
–40°
C
25A
115
58
160
80
–20°
C
120
60
160
80
–10°
C
125
63
160
80
10° C
98
50
140
70
–40°
C
32A
125
63
160
80
–20°
C
125
63
160
80
–10°
C
125
63
160
80
10° C
F.A.T.I. Via A. Volta, 52 · 20090 Cusago (MI) [email protected] · www.fati.com
A 15FFBT-XB 26FFBT-X
Pipe temperature °C
0
10
20
30
0 10 20 30 40 50 60
W/m
°C
W/m
Features The FCTU series of self-regulating heating cables are designed to supply a specified amount of heat at any point along their length in direct response to local temperature variations. These cables can maintain temperatures up to 375°F (190°C) and will withstand 190 psig saturated steam purging and intermittent temperature excursions to 475°F (250°C) with power applied. FCTU cables can be cut to length and terminated in the field, and will not overheat or burnout when overlapped.
FCTU
Self Regulating Heating Cable
Application
·The industrial grade FCTU cables provide freeze protection and process temperature maintenance for fluid transport and storage systems requiring very high levels of heat output or exposure to elevated temperatures. The bus wires, jackets and metallic braids can be configured for both ordinary (non-classified) locations and hazardous (classified), including areas where exposure to corrosive or organic materials is possible.
FATI-FCTU · 1/2
Technical data
Output wattage (other wattages also available) 15, 30, 45, 60w/m @ 0°C
Supply voltages 110-120 or 208V-277Vac
Continuous maintenance temperature 375°F (190°C) max
Intermittent exposure temperature 475°F (250°C) max
T Rating Temperature Class T2
Braid resistance 0.009Ohm/mt
Size 11.0mmx5.2mm
Min. bending radius 33mm
Self-regulating Fluoropolymer conductive core
Inner insulation
Nickel copper overshield
Nickel coated copper buswires
Optional outer jacket
FCTUSelf Regulating Heating Cable
Product ordering information
FATI-FCTU · 2/2
Power Adjustment FactorPart No. 208 Volts 277 Volts
15FCTU2-CT 0.87 1.17
30FCTU2-CT 0.88 1.14
45FCTU2-CT 0.90 1.10
60FCTU2-CT 0.94 1.08
0
10
20
30
40
50
60
70
0 10 20 30 40 50 60 70 80 90 100110120130140150160170180
W/m
°C
C
D
B
A
A 15FCTUB 30FCTUC 45FCTUD 60FCTU
Pipe temperature °C
Power output curvesNominal power output at 230V when FCTU is installed on insulated pipes
FCTU - C For example: 15FCTU2-CTor example: 15HTP2-CTOuter jacketT=FluorpolymerNickel CopperSupply Voltage1=110-120VAC; 2=208-277VACType of cable
Power in W/mt at 10°C15=15W/mt; 30=30W/mt 45=45W/mt; 60=60W/mt
F.A.T.I. Via A. Volta, 52 · 20090 Cusago (MI) [email protected] · www.fati.com
MinimumStart-up temperature
CB sizeAmps
15FCTU 30FCTU 45FCTU 60FCTU
120V 240V 120 V 240V 120 V 240V 120 V 240V
50℉(10℃)
15 55 110 37 73 24 49 18 35
20 73 146 49 98 32 64 27 46
30 102 165 55 110 41 82 37 70
0℉(-20℃)
15 50 99 32 70 21 43 17 33
20 67 131 43 93 27 56 21 44
30 100 165 55 110 41 82 34 67
-50℉(-45℃)
15 46 88 27 69 18 37 15 32
20 61 117 37 91 24 49 20 43
30 91 165 55 110 37 73 30 64
Maximum length (mt) vs. circuit breaker size
W/m
t
Features
· Energy efficient, automatically varies its power output in response to pipe temperature changes. · Easy to install, can be cut to any length (up to max circuit length) required on site with no wasted cable. · Lower installed cost than steam tracing, less maintenance expense and less downtime. · No overheat or burnout even when wrapped over itself (overlapped). · Suitable for use in non-hazardous, hazardous and corrosive environments. · FATI power connection, splice, tee and end seal kit will reduce installation time. Optional outer jacket, the heating cable is resistant to watery and inorganic chemicals and corrosive.
Option
·FCTS…C Tinned copper braid provide additional mechanical protection and a positive ground path. ·FCTS…CT High Temperature Fluoropolymer overjacket are used for exposure to organic or corrosive solutions or vapours may be present.
FCTS
Self Regulating Heating Cable
Application
FCTS is an industrial grade, self-regulating parallel heating cable (heating tape) manufactured in accordance to BS6351 Grade 22, that can be used for applications ranging from process heating or maintenance of temperature up to 150℃. It can be used in hazardous and non-hazardous locations, including areas where corrosives may be present.
FATI-FCTS · 1/2
Technical data
Service voltage 110-120V, 220-277V
Maximum maintain or continuousexposure temperature (power on) +120℃ (248℉)
Maximum intermittent exposure temperature 1000 hours (power on or off)
+200℃ (392℉)
Minimum installation temperature -30℃ (-22℉)
Protective braid resistance ﹤18.2Ω/km
Bus wire gauge 16 AWG
Approvals CE
Self-regulating semi-conductive core
Inner insulation
Tinned copper braid
Tinned copper buswires16 AWG
Optional outer jacket
0
10
20
30
40
50
60
70
80
0 10 20 30 40 50 60 70 80 90 100 110 120
W/m
°C
FATI-FCTS · 2/2
F.A.T.I. Via A. Volta, 52 · 20090 Cusago (MI) [email protected] · www.fati.com
FCTS
Self Regulating Heating Cable
Dimension and weight
Product ordering information Power output curvesNominal power output at 240V when FCTS installed on insulated metal pipes.
Pipe temperature °C
A 5FCTSB 10FCTSC 15FCTSD 20FCTSD
C
B
A
Maximum length (mt) vs. circuit breaker size
MinimumStart-up temperature
CB sizeAmps
5FCTS230Vmt
10FCTS230Vmt
15FCTS230Vmt
20FCTS230Vmt
-20℃(-4℉)
16 120 80 55 40
25 205 125 85 65
32 220 155 105 80
40 220 155 135 110
10℃(50℉)
16 150 90 60 45
25 225 140 95 70
32 225 150 125 90
40 225 150 135 110
Type Dimension Min.bending radius
Weight (kg/100mt)
FCTS…C 9.2×3.6mm 21mm 11.2
FCTS…CR 10.9×6.0mm 36mm 11.0
FCTS - C For example: 15FCTS2-CT
Outer jacketT=FluorpolymerTinned Copper BraidSupply Voltage1=110-120VAC; 2=220-277VACType of cable
Power in W/mt at 10°C5=18W/mt; 10=35W/mt15=50W/mt; 20=65W/mt
W/m
t
Features
· Energy efficient, automatically varies its power output in response to pipe temperature changes.· Easy to install, can be cut to any length (up to max circuit length) required on site with no wasted cable.· Lower installed cost than steam tracing, less maintenance expense and less downtime.· No overheat or burnout even when wrapped over Itself (overlapped) .· Suitable for use in non-hazardous, hazardous and corrosive environments.· FATI power connection, splice, tee and end seal kit will reduce installation time. Optional outer jacket, the heating cable is resistant to watery and inorganic chemicals corrosive
Option
·FCTR…C Tinned copper braid provide additional mechanical protection and a positive ground path. ·FCTR…CR Flame retardant thermoplastic over jacket protect against certain inorganic chemical solutions, it also protect against abrasion and impact damage. ·FCTR…CT High Temperature Fluoropolymer. Over jacket are used for exposure to organic or corrosive solutions or vapours.
FCTR
Self Regulating Heating Cable
Application
FCTR is Industrial Rate approved self-regulating parallel heating cable (heating tape), designed for a variety of industrial applications and enviroments, including hazardous and non-hazardous. It can be used for plastic or mental pipe freeze protection and flow maintenance of pipes, tanks, valves.
FATI-FCTR · 1/2
Technical data
Service voltage 110-120V, 220-277V
Maximum maintain or continuousexposure temperature (power on) +65℃ (149℉)
Maximum intermittent exposure temperature 1000 hours (power on or off)
+85℃ (185℉)
Minimum installation temperature -40℃ (-40℉)
Protective braid resistance ﹤18.2Ω/km
Bus wire gauge 16 AWG
Self-regulating semi-conductive core
Inner insulation
Tinned copper braid
Tinned copper buswires16 AWG
Optional outer jacket
0
10
20
30
40
50
60
0 10 20 30 40 50 60 70
W/m
°C
Power output curvesNominal power output at 240V when FCTR installed on insulated metal pipes.
Pipe temperature °C
C
B
E
A
D
A 3FCTRB 5FCTRC 8FCTRD 10FCTRE 12FCTR
FCTRSelf Regulating Heating Cable
Product ordering information
FATI-FCTR · 2/2
Dimension and weight
Type Dimension Min.bending radius
Weight (kg/100mt)
FCTR…C 11.0×4.4mm 26mm 10.5
FCTR…CR 12.6×6.0mm 36mm 13.8
FCTR…CT 12.0×5.4mm 32mm 13.0
FCTR - C For example: 5FCTR2-CT
Outer jacketR=Thermoplastic; T=FluorpolymerTinned Copper BraidSupply Voltage1=110-120VAC; 2=220-277VACType of cable
Power in W/mt at 10°C3=12W/mt; 5=18W/mt; 8=25W/mt 10=35W/mt; 12=42W/mt
Maximum length (mt) vs. circuit breaker size
Circuit Breaker
Size
Start-up Temperature
3FCTR 5FCTR 8FCTR 10FCTR 12FCTR
120V 230V 120V 230V 120V 230V 120V 230V 120V 230V
16A
–40°C 48 95 48 67 48 48 48 38 48 28
–20°C 76 150 76 105 76 70 76 45 76 35
–10°C 86 170 86 125 86 82 86 50 86 40
10°C 100 200 100 158 100 110 100 65 100 52
20A
–40°C 63 125 63 90 63 64 63 50 63 36
–20°C 96 190 96 136 96 90 96 55 96 48
–10°C 98 195 98 145 98 103 98 65 98 54
10°C 100 200 100 160 100 125 100 85 100 64
25A
–40°C 78 155 78 110 78 76 78 62 78 48
–20°C 100 200 100 160 100 110 100 70 100 60
–10°C 100 200 100 160 100 120 100 92 100 76
10°C 96 190 96 140 96 96 96 80 96 60
32A
–40°C 96 190 96 140 96 96 96 80 96 60
–20°C 100 200 100 160 100 125 100 90 100 75
–10°C 100 200 100 160 100 125 100 102 100 87
10°C 100 200 100 160 100 125 100 110 100 95
F.A.T.I. Via A. Volta, 52 · 20090 Cusago (MI) [email protected] · www.fati.com
W/m
t
Features
· Energy efficient, automatically varies its power output in response to pipe temperature changes. · Easy to install, can be cut to any length (up to max circuit length) required on site with no wasted cable. · Lower installed cost than steam tracing, less maintenance expense and less downtime. · No overheat or burnout even when wrapped over Itself (overlapped). · Suitable for use in non-hazardous, hazardous and corrosive environments. · FATI power connection, splice, tee and end seal kit will reduce installation time. · Optional outer jacket, the heating cable is resistant to watery and inorganic chemicals and corrosive.
Option
·FCTP…C Tinned copper braid provide additional mechanical protection and a positive ground path. ·FCTP…CR Flame retardant thermoplastic over jacket protect against certain inorganic chemical solutions, it also protect against abrasion and impact damage. ·FCTP…CT High Temperature Fluoropolymer over jacket are used for exposure to organic or corrosive solutions or vapours may be present.
FCTP
Self Regulating Heating Cable
Application
FCTP is Industrial Rated approved self-regulating parallel heating cable, designed for pipe heat tracing in industrial applications, it is configured for use in hazardous and non-hazardous locations, including areas where corrosives may be present. It can provide process temperature maintenance up to 110℃ (230℉) and it can also be used for frost protection of large pipes and freeze protection in systems having high heat loss.
FATI-FCTP · 1/2
Technical data
Service voltage 110-120V, 220-277V
Maximum maintain or continuousexposure temperature (power on) +110℃ (230℉)
Maximum intermittent exposure temperature 1000 hours (power on or off)
+135℃ (275℉)
Minimum installation temperature -30℃ (-22℉)
Protective braid resistance ﹤18.2Ω/km
Bus wire gauge 16 AWG (17&31W/mt)14 AWG (45&60W/mt)
Approvals CE
Self-regulating semi-conductive core
Inner insulation
Tinned copper braid
Tinned copper buswires14 AWG/16 AWG
Optional outer jacket
0
10
20
30
40
50
60
70
80
0 10 20 30 40 50 60 70 80 90 100 110
W/m
°C
FATI-FCTP · 2/2
F.A.T.I. Via A. Volta, 52 · 20090 Cusago (MI) [email protected] · www.fati.com
FCTP
Self Regulating Heating Cable
Dimension and weight
Product ordering information Power output curvesNominal power output at 230V when FCTP is installed on insulated pipes.
Pipe temperature °C
Type Dimension Min.bending radius
Weight (kg/100mt)
FCTP…C 12.0x4.4 26mm 9.5
FCTP…CR 13.6x6.0 36mm 11.0
FCTP…CT 12.4x4.8 28mm 13.9
A 5FCTPB 10FCTPC 15FCTPD 20FCTPD
C
B
A
Maximum length (mt) vs. circuit breaker size
MinimumStart-up temperature
CB sizeAmps
5FCTP230Vmt
10FCTP230Vmt
15FCTP230Vmt
20FCTP230Vmt
-20℃(-4℉)
16 110 65 63 47
25 130 95 75 60
32 130 115 100 75
40 130 115 100 95
10℃(50℉)
16 120 80 63 47
25 130 115 95 75
32 130 115 100 95
40 130 115 100 95
FCTP - C For example: 5FCTP2-CT
Outer jacketR=Thermoplastic; T=FluorpolymerTinned Copper BraidSupply Voltage1=110-120VAC; 2=220-277VACType of cable
Power in W/mt at 10°C5=10W/mt; 10=35W/mt 15=48W/mt; 20=60W/mt
W/m
t
Features · Energy efficient, automatically varies its power output in response to pipe temperature changes.· Easy to install, can be cut to any length (up to max circuit length) required on site with no wasted cable.· Lower installed cost than steam tracing, less maintenance expense and less downtime.· No overheat or burnout even when wrapped over Itself (overlapped).· Suitable for use in non-hazardous, hazardous and corrosive environments.· FATI power connection, splice, tee and end seal kit will reduce installation time. Optional outer jacket, the heating cable is resistant to watery and inorganic chemicals and corrosive.
Option
·FCTM…C Tinned copper braid provide additional mechanical protection and a positive ground path. ·FCTM…CR Flame retardant thermoplastic over jacket protect against certain inorganic chemical solutions, it also protect against abrasion and impact damage. ·FCTM…CT High Temperature Fluoropolymer over jacket are used for exposure to organic or corrosive.
FCTM
Self Regulating Heating Cable
Application
FCTM is self-regulating parallel heating cable (heating tape) can provides safe, reliable heat tracing for freeze protection or temperature maintenance of pipes, valves, flanges. It is suitable for use on small diameter plastic or mental pipes and instrument tubing in residential/light commercial and similar applications.
FATI-FCTM · 1/2
Technical data
Service voltage 110-120V, 220-277V
Maximum maintain or continuousexposure temperature (power on) +65℃ (149℉)
Maximum intermittent exposure temperature 1000 hours (power on or off)
+85℃ (185℉)
Minimum installation temperature -40℃ (-40℉)
Protective braid resistance ﹤18.2Ω/km
Bus wire gauge 20 AWG
Self-regulating semi-conductive core
Inner insulation
Tinned copper braid
Tinned copper buswires20 AWG
Optional outer jacket
0
10
20
30
40
0 10 20 30 40 50 60 70
W/m
°C
FCTMSelf Regulating Heating Cable
Product ordering information Power output curvesNominal power output at 230V when FCTM is installed on insulated pipes
Pipe temperature °C
FATI-FCTM · 2/2
C
B
A
Dimension and weight
A 3FCTMB 5FCTMC 8FCTM
Type Dimension Min.bending radius
Weight (kg/100mt)
FCTM…C 7.8×4.9mm 29mm 6.0
FCTM…CR 8.6×5.7mm 34mm 7.5
FCTM…CT 8.0×5.1mm 30mm 7.1
Maximum length (mt) vs. circuit breaker size
MinimumStart-up temperature
CB sizeAmps
3FCTM230Vmt
5FCTM230Vmt
8FCTM230Vmt
10℃(50℉)
10 123 85 65
16 128 102 88
25 128 112 117
0℃(32℉)
10 98 81 52
16 120 99 77
25 120 102 103
F.A.T.I. Via A. Volta, 52 · 20090 Cusago (MI) [email protected] · www.fati.com
FCTM - C For example: 5FCTM2-CR
Outer jacketR=Thermoplastic; T=FluorpolymerTinned Copper BraidSupply Voltage1=110-120VAC; 2=220-277VACType of cable
Power in W/mt at 10°C3=15W/mt; 5=18W/mt 8=28W/mt
W/m
t
Features · Energy efficient, automatically varies its power output in response to pipe temperature changes. · Easy to install, can be cut to any length (up to max circuit length) required on site with no wasted cable. · Lower installed cost than steam tracing, less maintenance expense and less downtime. · No overheat or burnout even when wrapped over itself (overlapped). · Suitable for use in non-hazardous, hazardous and corrosive environments. · FATI power connection, splice, tee and end seal kit will reduce installation time. Optional outer jacket, the heating cable is resistant to watery and inorganic chemicals and corrosive.
Option
·FCTL…C Tinned copper braid provide additional mechanical protection and a positive groundpath. ·FCTL…CR Flame retardant thermoplastic overjacket protect against certain inorganic chemical solutions, it also protects against abrasion and impact damage. ·FCTL…CT High Temperature Fluoropolymer overjacket are used for exposure to organic or corrosive solutions or vapors may be present.
FCTL
Self Regulating Heating Cable
Application
FCTL is CE compliant self-regulating parallel heating cable (heating tape) is designed for residentialand commercial metal and plastic pipe freeze protection and roof and gutter de-icing applications. It is ideal for use in maintaining fluid flow under low ambient. Freeze protection and low watt density process temperature systems such us pipelines, fire protection, process water, dust suppression systems, hot water and structure anti-icing are typical applications for this product. A UV stabilized thermoplastic elastomer overjacket is provided to cover the braid for wet applications and exposure to the sun.
FATI-FCTL · 1/2
Technical data
Service voltage 110-120V, 220-277V
Maximum maintain or continuousexposure temperature (power on) +65℃ (149℉)
Maximum intermittent exposure temperature 1000 hours (power on or off)
+85℃ (185℉)
Minimum installation temperature -40℃ (-40℉)
Protective braid resistance ﹤18.2Ω/km
Bus wire gauge 16 AWG
Approvals CE
Self-regulating semi-conductive core
Inner insulation
Tinned copper braid
Tinned copper buswires16 AWG
Optional outer jacket
FCTL
Self Regulating Heating Cable
Product ordering information
Power output curvesNominal power output at 230V when FCTLis installed on insulated pipes
Pipe temperature °C
FATI-FCTL · 2/2
Dimension and weight
Type Dimension Min.bending radius
Weight (kg/100mt)
FCTL…C 9.3×4.4mm 26mm 9.7
FCTL…CR 10.9×6.0mm 36mm 11.0
FCTL…CT 10.3×5.4mm 32mm 9.5
0
10
20
30
40
50
0 10 20 30 40 50 60 70
W/m
°C
A 3FCTLB 5FCTLC 8FCTLD 10FCTL
FCTL - C For example: 5FCTL-CR
Outer jacketR=Thermoplastic; T=FluorpolymerTinned Copper BraidSupply Voltage1=110-120VAC; 2=220-277VACType of cable
Power in W/mt at 10°C3=10W/mt; 5=18W/mt 8=27W/mt; 10=33W/mt
Maximum length (mt) vs. circuit breaker size
Circuit Breaker
Size
Start-up Temperature
3FCTL 5FCTL 8FCTL 10FCTL
120V 230V 120V 230V 120V 230V 120V 230V
16A
–40°C 46 90 33 65 25 48 18 36
–20°C 73 145 50 100 36 72 22 42
–10°C 83 165 60 120 43 85 25 48
10°C 100 200 78 155 55 110 32 62
20A
–40°C 60 120 43 85 34 66 25 48
–20°C 93 185 66 132 46 92 26 52
–10°C 95 190 73 145 53 105 32 62
10°C 100 200 80 160 63 125 42 82
25A
–40°C 76 152 55 110 40 80 30 60
–20°C 100 200 80 160 58 115 35 68
–10°C 100 200 80 160 60 120 45 90
10°C 100 200 80 160 63 125 50 100
32A
–40°C 95 188 70 140 50 98 40 78
–20°C 100 200 80 160 63 125 45 88
–10°C 100 200 80 160 63 125 50 100
10°C 100 200 80 160 63 125 53 105
F.A.T.I. Via A. Volta, 52 · 20090 Cusago (MI) [email protected] · www.fati.com
D
C
B
A
W/m
t
Application FCHW self-regulating heating cable are installed on hot water supply pipes underneath standard pipe insulation.The heating cable replaces supply-pipe heating loses at the point where the heat loss occurs, thereby providing continuous, energy-efficient, hot water temperature maintainance and eliminating theneed for a recirculation.
FCHW
Self Regulating Heating Cable
Features
·Energy efficient, automatically varies its power output to compensate for variations in water temperature and ambient temperature. ·Easy to install, can be cut to any length (up to max. circuit length) required on site with no wasted cable. ·Lower installed cost than steam tracing, less maintenance expense and less downtime. ·No overheat or burnout even when wrapped over itself (overlapped). ·Low operating cost, the FCHW system continuously maintains hot water temperature at every point along the supply pipe. ·FCHW systems eliminate the need for designing complex recirculation systems, with their pumps, piping net-works, and complicated flow balancing.
FATI-FCHW · 1/2
Self-regulating semi-conductive core
Inner insulation
Tinned copper braid
Tinned copper buswires16 AWG
Optional outer jacket
Immediate hot water when required
FCHWSelf Regulating Heating Cable
FATI-FCHW · 2/2
Specifications
FCHW-Y FCHW-O FCHW-R
Breaker size 230V 230V 230V
13A 110mt 65mt 65mt
16A 140mt 80mt 80mt
20A 180mt 100mt 100mt
MODEL FCHW-Y FCHW-O FCHW-R
Jacket color Yellow Orange Red
Bus wires 16 AWG 16 AWG 16 AWG
Maintainance temperature 40℃ to 50℃ 40℃ to 50℃ 40℃ to 60℃
Max. exposure temperature 65°C 65°C 80°C
Nominal power output 7 W/mt at 45°C 9 W/mt at 55°C 12 W/mt at 70°C
Minimum bend radius 20mm 20mm 20mm
Supply voltage 208~240V 208~240V 208~240V
Maximum circuit length
F.A.T.I. Via A. Volta, 52 · 20090 Cusago (MI) [email protected] · www.fati.com
W W W . F A T I . C O M
F.A.T.I. Srl Via Volta, 52
20090 Cusago (Milano - Italy) Tel. +39 0290119641 Fax +39 029019548
E-mail [email protected]