Heat Pump Wiring Diagrams - Alpine Home Air Products Pump Wiring Diagrams.pdf · Wire Size: 18 Gage...
Transcript of Heat Pump Wiring Diagrams - Alpine Home Air Products Pump Wiring Diagrams.pdf · Wire Size: 18 Gage...
1(800) 865-5931www.alpinehomeair.com
AC Heat Pump with Single Stage Gas Furnace and All Fuel Kit Control Wiring
Heat Pump
Standard Thermostat
Standard Furnace
Outdoor Heat Pump Thermostat
24 Volt+
Fan Only Operation
Air Conditioning
Common
1st Stage Backup Heat
AC Reversing Valve
Control Board
Low Voltage Connection
All Fuel Kit
Thermostat
Furnace Condenser
9Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.
This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment
installation guides to verify proper wiring.
NOTE
O
O
O
O
O
O
1 2 3
1(800) 865-5931www.alpinehomeair.com
AC Heat Pump with Single Stage Gas Furnace and Honeywell VisionPro 8000 as All Fuel Kit Control Wiring
Heat Pump
Honeywell VisionPro 8000
Standard Furnace
24 Volt+
Fan Only Operation
Air Conditioning
1st Stage Gas Heat
AC Reversing Valve
Common
Outdoor Temp Sensor
Outdoor Temp Sensor
Control Board
Low Voltage Connection
10Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.
This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment
installation guides to verify proper wiring.
NOTES *Vision Pro 8000 works with wired or wireless outdoor temp sensor.
O
O
O
Y2
*To Outdoor Temp Sensor
AUX/E
AUX/E
Factory Jumper
Wire Size: 18 Gage
1(800) 865-5931www.alpinehomeair.com
AC Heat Pump with Standard Air Handler and No Electric Backup Heat
Standard Heat Pump Thermostat
Standard Air Handler
Heat Pump Condenser
24 Volt+
Fan Only Operation
Common
Air Conditioning-Heat Pump
Reversing Valve
1st Stage Heat (white)
2nd Stage Heat (brown)
Low Voltage Connection
11Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.
This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment
installation guides to verify proper wiring.
NOTE
O
O
O
Wire Size: 18 Gage
1(800) 865-5931www.alpinehomeair.com
AC Heat Pump with Standard Air Handler and Single Stage Electric Backup Heat
Standard Heat Pump Thermostat
Heat Pump Condenser
24 Volt+
Fan Only Operation
Common
Air Conditioning-Heat Pump
Reversing Valve
Electric Backup Heat
Low Voltage Connection
12Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.
This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment
installation guides to verify proper wiring.
NOTE
O
O
O
Standard Air Handler
AUX/E
Wire Size: 18 Gage
1(800) 865-5931www.alpinehomeair.com
AC Heat Pump with Standard Air Handler and Two Stage Electric Backup Heat
Standard Heat Pump Thermostat
Standard Air Handler
Heat Pump Condenser
24 Volt+
Fan Only Operation
Common
Air Conditioning-Heat Pump
Reversing Valve
1st Stage Heat Gas
Electric Backup Heat
Low Voltage Connection
13Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.
This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment
installation guides to verify proper wiring.
NOTE
O
O
O
Tied together
AUX/E
AUX/E
Wire Size: 18 Gage
1(800) 865-5931www.alpinehomeair.com
AC Heat Pump with Variable Speed Air Handler Without Electric Backup Heat Control Wiring
Standard Heat Pump Thermostat
Variable Speed Air HandlerHeat Pump Condenser
Low Voltage Connection
14Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.
This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment
installation guides to verify proper wiring.
NOTE
O
O
O
AUX/E
24 Volt+
Fan Only Operation
Common
Air Conditioning-Heat Pump
Reversing Valve
1st Stage Heat Gas
Electric Backup Heat
O
AUX/E
Y1 W1
Wire Size: 18 Gage
1(800) 865-5931www.alpinehomeair.com
AC Heat Pump with Variable Speed Air Handler and Single Stage Electric Backup Heat Control Wiring
15Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.
This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment
installation guides to verify proper wiring.
NOTE
24 Volt+
Fan Only Operation
Common
Air Conditioning-Heat Pump
Reversing Valve
1st Stage Heat Gas
Electric Backup Heat
O
AUX/E
Single Stage Heat Pump Thermostat
Variable Speed Air Handler
Heat Pump Condenser
Low Voltage ConnectionO
O
O
AUX/E
Tied together
Y1
Y2
W1
Wire Size: 18 Gage
1(800) 865-5931www.alpinehomeair.com
AC Heat Pump with Variable Speed Air Handler and Two Stage Electrical Backup Heat Control Wiring
16Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.
This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment
installation guides to verify proper wiring.
NOTE
24 Volt+
Fan Only Operation
Common
Air Conditioning-Heat Pump
Reversing Valve
1st Stage Heat Gas
Electric Backup Heat
O
AUX/E
Standard Heat Pump Thermostat
Variable Speed Air HandlerHeat Pump Condenser
Low Voltage ConnectionO
O
O
AUX/E
W1
Y1