Heat pump Technical Training
Transcript of Heat pump Technical Training
2
ALFEA Extensa
Excellia
Cascade
ALFEA DUO
Extensa
Excellia
Alfea
4
ALFEA Hybrid
DUO GAZ
ALFEA Hybrid
DUO FIOUL
Hybrid
5
Heat pump Range
New house Housing Renovation
16
8
5
M
M
M
M
T
T
T
Loria Alféa
Excellia
Alféa
Extensa +
6
10 | 11
13 | 14
M
M
M
M
M
M
Alféa
Hybrid Duo GazAlféa
Extensa Duo +
M
M
T
T
T
Alféa
Excellia Duo
M
M
T
T
T
M
M
T
T
T
Alféa Hybrid
Duo Oil
Low Nox
M
M
M
M
Aérothermie Split
4 M
Loria
Duo
M
M
M
M M
M
M M
16
M T
7
Hysaé hybride
Gaz
Split
Hynéa hybride
Gaz
Boiler. 12 kW
DHW 14L / min DHW 20L / min
HP 3 kW
Boiler. 24 kW
New house
9
Atlantic Géolia
New house / Housing Renovation
Atlantic Géolia
M
M
T
T
M
17
7
5
10
13
Géothermie
until 60°C*
* According to the model and type of colector
11
Performances 5 kW 6 kW 8 kW 10 kW 13 kW 16 kW
working range : -20℃ / +35℃ (hot)
+8°C / +43°C (cold)
ALFEA Extensa
Models
12
Excellia mono Tri
Models
On the floor hot/Cold
Performances
Mono11 kW 14 kW
Working range : -25℃ / +35℃ (heating)
8°C / 43°C (cooling)
On the floor hot/Cold Tri11 kW 14 kW 16kW
13
ALFEA ExcelliaCompressor
Realize high condensing temperature !
Evaporator
Heating unit
Liquid injection
If outside temperature is below 10°C
It realize the high pressure without rising
the discharge gas temperature by liquid
injection during compression
Liquid injection
Outdoor unit
Indoor unit
Refrigerant cycle
Additional bypath circuit
Pressure Maxi 42 bars
Pressure Mini 1.2 bar
14
Refrigerated connections
R410A
Size
5 m
7 m
10 m
25m
2 packs : Outdoor Unit + Hydraulic Unit (without accessories)
Anti-vibration blocks
OUTDOOR ACCESSORIES
Wall support
Outdoor Unit
600 mm
PVC floor support
450 mm
Or
coutchouc support
Optional equipements
Heating Câble
ALFEA
!
Gutter
Condenser tray
5,6 and 8kW
16
Alféa extensa + / Duo
Mini
5 m Maxi 20 m (with
complement)
Maxi without
refrigerant
complement
Complement depending on
recommandation (manual)
Complement depending
on recommandation
15 mComplement depending
on recommandation
15 m
15 mComplement depending
on recommandation
5 à 6 kW
8 kW
13 - 16 kW
15 m
15 mComplement depending
on recommandation 10 kW
Maxi 30 m (with
complement)
20
m
20
m
30
m
30
m
Refrigerant connection
Alféa excellia + / Duo
15 mComplement depending
on recommandation 20
m11 – 14 - 16 kW
18
Inspection panel for
Electric back-ups
Coaxial exchanger
4,5 turns
Refrigareted
connection
Hydraulic connection
By-pass 8,5
20
• Compressor modulation evolves from 10 to 30 steps(only for output capacity from 5 to 8 kW)
Inverter management optimised
Increasing operating flexibility
Improvment of seasonal efficiency
Outdoor units - Performances
* From deliveries of September 2015
21
Heating and Inverter
+20 +10 0 -10
40
30
20
T° Outdoor
T°
Flo
w
0,7
T°C Flow: 40°C
T°C outdoor : -10°C
Slope = 20/30= 0,67
% o
f m
od
ula
tio
n
Time
100%
34°C
10 or 30 steps Max
60%
ALFEA
22
+20 +10 0 -10
40
30
20
T° Outdoor
T°
Flo
w
0,7
T°C Flow: 40°C
T°C outdoor : -10°C
Slope = 20/30= 0,67
% o
f m
od
ula
tio
n
Time
34°C60%
LORIA
Heating and Inverter
23
HYDRAULIC OPTIONS
ALFEA
Accessoires hydrauliques
Electric back-ups
Monophase 6kW Electric back-ups
Triphase 9kW
24
Alfea Extensa
Electric backup single phase
You have to replace the manual air bleeder by an automatic with the electric back-ups kit
=> If the heat exchanger is badly drained, risk to release the safety thermostat
Automatic air
bleeder
Relay 1° and 2° level
Terminal block
Safety thermostat
Adjustable
Electric back-ups
3 or 6kW
25
Alfea Excellia
Electric back-ups tri-phases
Electric back-ups tri-phases 9kW
Modulating relay
Terminal block
Safety thermostat Card connection
X82
26
Improvement of the performances –by combining thermo-electric
Electric back-ups
3 – 6 kW OPTION1st flow:
thermodynamic
2nd flow:
electric
27
LORIA Heat exchanger
Plate exchanger
Back-up safety
thermostat 90°C
Electric back-ups
3 kw stainless steel
vessel
automatic drainer
28
• No additionnal gas needed until 15 m
• Increase of maximum lenght between outdoor unit and hydraulic unit for output capacity from 5 to 8 kW *
Up to 30m (additional gas required)
More flexibility to install outdoor unit
Outdoor unit - Integration
* From deliveries of September 2015
29
• Integration of communication between the outdoor unit and the hydraulic module for information feedback
• Outdoor unit :LED flashes counting on outdoor unit and hydraulic unit
interface card red + green
• Hydraulique unit :
Information displayed on hydraulic unit screen (code XX)
Facilitated Installation and maintenance
Easier diagnosis
Outdoor unit – Communication with hydraulic unit
ALFEA
30
• More refreshment functions
• 2 zones cooling mode • Example : 1 zone heating floor + 1 zone fan coil
• Time programme for each zone
• For cascade (before sale department validation needed)
• Gaz hybrid system
Ability to cover more projects
Increased comfort even in summer
Hydraulic – Cooling
All ranges
31
• Estimated consumption read directly on the screen of the hydraulic module (heating and DHW)
Hydraulic unit - Regulation
All range
32
Heat pump Range
• ControllerNew settings
Energy meter
•3113 - 3189 S Counters for energy brought in heating – DHW - Cooling
•3197 U Compressor electrical power
33
Air bleeder
Expansion vessel
class A circulating pump
Tank 16L + Coaxial Exchanger
Controller box
Refrigerated connections
Hydraulic connectionsManometer
Safety valve
FlowReturn
Heating only
Module hydraulique Composants
34
Hydraulic part
Controller box
DHW drain valve
Drain valve
DHW electric back-ups
DUO
Hydraulic Modul Components
New insulated Tank 190L ACI
Refrigerated connections
36
Parametre 5700 : Start up level « installor »
• Pré-setting 1 : 1 heating circuit.
• Pré-setting 2 : 2 heating circuits.
• Pré-setting 3 : Boiler connection and 1 heating circuit.
• Pré-setting 4 : Boiler connection and 2 heating circuits.
Setting
37
ALFEA heating only
Accessoires hydrauliques
HYDRAULIC OPTIONS
Balancing vessel
High flow
Circulating pumpBoiler Kit2° circuit kit
38
Kit DHW
Heating only
Hydraulic accessories
Swiming pool
KitSwiming pool
KitMileo 200 (1,8 m²)
300L (2,6m²) (3,3kW)
Mileo + 200 (2,5m²)
300L (3,5m²)
Buffer tank
25 or 50L
39
DHW kit Alféa to connect a cylinder - Réf. 073 991
New :
MILEO 200
MILEO 300
MILEO + 200
MILEO + 300
MILEO 160
MILEO + 160
MILEO 400
MILEO + 400
MILEO 500
MILEO + 500
Cylinder
40
Heating only
2 circuits Configuration
Class A circulating pumpintegrated
Alfea Class A circulating pump
Mixing valve
Extension Card to
manage 2 circuits
(Option)
41
• Application :
Floor heating
radiators
Préparation DHW
Heating only
Boiler option
Boiler kit ( integrated option)
42
OptionIntegrated
or
1 to 3 circuits – 2 zones possible
20°
15°
10°
2°
0°
-5°
-10°
TA Contact
ABA
B
Outside sensor
Alfea
Boiler option
43
Option
20°
15°
10°
2°
0°
-5°
-10°
Integrated
or
1 to 3 circuits – 2 zones possible
TA Contact
Outside sensor
Alfea
Boiler option
44
ACCESSOIRES HYDRAULIQUES
ALFEA DUO
Accessoires hydrauliques
Balancing vessel
High flow
rate pump
Boiler Kit2° circuit kit
45
ACCESSOIRES HYDRAULIQUES
DHW expansion kit
ALFEA DUO
Accessoires hydrauliques
Swiming pool
KitPool
exchangeurBuffer tank
25 or 50L
46
• Allow to adapt the hydraulique connections behind the jacket and on the top, For Alféa Extensa Duo + et Alféa Excellia Duo
Exemple kit 2ème zone
It exists 2 kits, 1 for 1 circuit and a
2° for 2 zones .
The pipes are insulated in case
Alféa Duo is used for cooling
(Cooling kit in option).
Hydraulique Kit duo top connections
Top pipes kit
49
Technical department
Before-sales [email protected]
Estimated studiesSoftware Projipac
After-sales [email protected]
GuarantiesSpare parts
[email protected]+33351427042
Training
50
Formations
o PAC 6-01 : Nouveau clients , Descriptif
Gamme, accessoires, bonnes pratiques,
Dimensionner une PAC aérothermique en neuf
et en rénovation / 1 jours
o PAC 6-10 : Paramétrer la régulation sur une
PAC aérothermique (gestion des sondes,
applications services et clients) / 1 jour
o PAC 6-04 : Mettre en service, entretenir et
dépanner une PAC aérothermique / 2 jours
o PAC 6-14 : Réaliser un diagnostic de panne
frigorifique sur une pompe à chaleur
aérothermique / 2 jours