Heat pump Technical Training

52
WELCOME Heat pump Technical Training

Transcript of Heat pump Technical Training

WELCOME

Heat pump

Technical Training

3

LORIA DUOLORIA

Loria

5

Heat pump Range

New house Housing Renovation

16

8

5

M

M

M

M

T

T

T

Loria Alféa

Excellia

Alféa

Extensa +

6

10 | 11

13 | 14

M

M

M

M

M

M

Alféa

Hybrid Duo GazAlféa

Extensa Duo +

M

M

T

T

T

Alféa

Excellia Duo

M

M

T

T

T

M

M

T

T

T

Alféa Hybrid

Duo Oil

Low Nox

M

M

M

M

Aérothermie Split

4 M

Loria

Duo

M

M

M

M M

M

M M

16

M T

6

Hynea Hybrid duoHysae Hybrid

7

Hysaé hybride

Gaz

Split

Hynéa hybride

Gaz

Boiler. 12 kW

DHW 14L / min DHW 20L / min

HP 3 kW

Boiler. 24 kW

New house

8

Geolia

9

Atlantic Géolia

New house / Housing Renovation

Atlantic Géolia

M

M

T

T

M

17

7

5

10

13

Géothermie

until 60°C*

* According to the model and type of colector

10

11

Performances 5 kW 6 kW 8 kW 10 kW 13 kW 16 kW

working range : -20℃ / +35℃ (hot)

+8°C / +43°C (cold)

ALFEA Extensa

Models

12

Excellia mono Tri

Models

On the floor hot/Cold

Performances

Mono11 kW 14 kW

Working range : -25℃ / +35℃ (heating)

8°C / 43°C (cooling)

On the floor hot/Cold Tri11 kW 14 kW 16kW

13

ALFEA ExcelliaCompressor

Realize high condensing temperature !

Evaporator

Heating unit

Liquid injection

If outside temperature is below 10°C

It realize the high pressure without rising

the discharge gas temperature by liquid

injection during compression

Liquid injection

Outdoor unit

Indoor unit

Refrigerant cycle

Additional bypath circuit

Pressure Maxi 42 bars

Pressure Mini 1.2 bar

14

Refrigerated connections

R410A

Size

5 m

7 m

10 m

25m

2 packs : Outdoor Unit + Hydraulic Unit (without accessories)

Anti-vibration blocks

OUTDOOR ACCESSORIES

Wall support

Outdoor Unit

600 mm

PVC floor support

450 mm

Or

coutchouc support

Optional equipements

Heating Câble

ALFEA

!

Gutter

Condenser tray

5,6 and 8kW

15

WALL IN

16

Alféa extensa + / Duo

Mini

5 m Maxi 20 m (with

complement)

Maxi without

refrigerant

complement

Complement depending on

recommandation (manual)

Complement depending

on recommandation

15 mComplement depending

on recommandation

15 m

15 mComplement depending

on recommandation

5 à 6 kW

8 kW

13 - 16 kW

15 m

15 mComplement depending

on recommandation 10 kW

Maxi 30 m (with

complement)

20

m

20

m

30

m

30

m

Refrigerant connection

Alféa excellia + / Duo

15 mComplement depending

on recommandation 20

m11 – 14 - 16 kW

17

18

Inspection panel for

Electric back-ups

Coaxial exchanger

4,5 turns

Refrigareted

connection

Hydraulic connection

By-pass 8,5

19

Stainless-

steel tank

Polystyrene

insulation

Coaxial

Exchanger

Condensation

sensor

20

• Compressor modulation evolves from 10 to 30 steps(only for output capacity from 5 to 8 kW)

Inverter management optimised

Increasing operating flexibility

Improvment of seasonal efficiency

Outdoor units - Performances

* From deliveries of September 2015

21

Heating and Inverter

+20 +10 0 -10

40

30

20

T° Outdoor

Flo

w

0,7

T°C Flow: 40°C

T°C outdoor : -10°C

Slope = 20/30= 0,67

% o

f m

od

ula

tio

n

Time

100%

34°C

10 or 30 steps Max

60%

ALFEA

22

+20 +10 0 -10

40

30

20

T° Outdoor

Flo

w

0,7

T°C Flow: 40°C

T°C outdoor : -10°C

Slope = 20/30= 0,67

% o

f m

od

ula

tio

n

Time

34°C60%

LORIA

Heating and Inverter

23

HYDRAULIC OPTIONS

ALFEA

Accessoires hydrauliques

Electric back-ups

Monophase 6kW Electric back-ups

Triphase 9kW

24

Alfea Extensa

Electric backup single phase

You have to replace the manual air bleeder by an automatic with the electric back-ups kit

=> If the heat exchanger is badly drained, risk to release the safety thermostat

Automatic air

bleeder

Relay 1° and 2° level

Terminal block

Safety thermostat

Adjustable

Electric back-ups

3 or 6kW

25

Alfea Excellia

Electric back-ups tri-phases

Electric back-ups tri-phases 9kW

Modulating relay

Terminal block

Safety thermostat Card connection

X82

26

Improvement of the performances –by combining thermo-electric

Electric back-ups

3 – 6 kW OPTION1st flow:

thermodynamic

2nd flow:

electric

27

LORIA Heat exchanger

Plate exchanger

Back-up safety

thermostat 90°C

Electric back-ups

3 kw stainless steel

vessel

automatic drainer

28

• No additionnal gas needed until 15 m

• Increase of maximum lenght between outdoor unit and hydraulic unit for output capacity from 5 to 8 kW *

Up to 30m (additional gas required)

More flexibility to install outdoor unit

Outdoor unit - Integration

* From deliveries of September 2015

29

• Integration of communication between the outdoor unit and the hydraulic module for information feedback

• Outdoor unit :LED flashes counting on outdoor unit and hydraulic unit

interface card red + green

• Hydraulique unit :

Information displayed on hydraulic unit screen (code XX)

Facilitated Installation and maintenance

Easier diagnosis

Outdoor unit – Communication with hydraulic unit

ALFEA

30

• More refreshment functions

• 2 zones cooling mode • Example : 1 zone heating floor + 1 zone fan coil

• Time programme for each zone

• For cascade (before sale department validation needed)

• Gaz hybrid system

Ability to cover more projects

Increased comfort even in summer

Hydraulic – Cooling

All ranges

31

• Estimated consumption read directly on the screen of the hydraulic module (heating and DHW)

Hydraulic unit - Regulation

All range

32

Heat pump Range

• ControllerNew settings

Energy meter

•3113 - 3189 S Counters for energy brought in heating – DHW - Cooling

•3197 U Compressor electrical power

33

Air bleeder

Expansion vessel

class A circulating pump

Tank 16L + Coaxial Exchanger

Controller box

Refrigerated connections

Hydraulic connectionsManometer

Safety valve

FlowReturn

Heating only

Module hydraulique Composants

34

Hydraulic part

Controller box

DHW drain valve

Drain valve

DHW electric back-ups

DUO

Hydraulic Modul Components

New insulated Tank 190L ACI

Refrigerated connections

35

Level

End user Start up Specialiste Factory setting

OEMSIU

Setting

36

Parametre 5700 : Start up level « installor »

• Pré-setting 1 : 1 heating circuit.

• Pré-setting 2 : 2 heating circuits.

• Pré-setting 3 : Boiler connection and 1 heating circuit.

• Pré-setting 4 : Boiler connection and 2 heating circuits.

Setting

37

ALFEA heating only

Accessoires hydrauliques

HYDRAULIC OPTIONS

Balancing vessel

High flow

Circulating pumpBoiler Kit2° circuit kit

38

Kit DHW

Heating only

Hydraulic accessories

Swiming pool

KitSwiming pool

KitMileo 200 (1,8 m²)

300L (2,6m²) (3,3kW)

Mileo + 200 (2,5m²)

300L (3,5m²)

Buffer tank

25 or 50L

39

DHW kit Alféa to connect a cylinder - Réf. 073 991

New :

MILEO 200

MILEO 300

MILEO + 200

MILEO + 300

MILEO 160

MILEO + 160

MILEO 400

MILEO + 400

MILEO 500

MILEO + 500

Cylinder

40

Heating only

2 circuits Configuration

Class A circulating pumpintegrated

Alfea Class A circulating pump

Mixing valve

Extension Card to

manage 2 circuits

(Option)

41

• Application :

Floor heating

radiators

Préparation DHW

Heating only

Boiler option

Boiler kit ( integrated option)

42

OptionIntegrated

or

1 to 3 circuits – 2 zones possible

20°

15°

10°

-5°

-10°

TA Contact

ABA

B

Outside sensor

Alfea

Boiler option

43

Option

20°

15°

10°

-5°

-10°

Integrated

or

1 to 3 circuits – 2 zones possible

TA Contact

Outside sensor

Alfea

Boiler option

44

ACCESSOIRES HYDRAULIQUES

ALFEA DUO

Accessoires hydrauliques

Balancing vessel

High flow

rate pump

Boiler Kit2° circuit kit

45

ACCESSOIRES HYDRAULIQUES

DHW expansion kit

ALFEA DUO

Accessoires hydrauliques

Swiming pool

KitPool

exchangeurBuffer tank

25 or 50L

46

• Allow to adapt the hydraulique connections behind the jacket and on the top, For Alféa Extensa Duo + et Alféa Excellia Duo

Exemple kit 2ème zone

It exists 2 kits, 1 for 1 circuit and a

2° for 2 zones .

The pipes are insulated in case

Alféa Duo is used for cooling

(Cooling kit in option).

Hydraulique Kit duo top connections

Top pipes kit

47

Connectivity

49

Technical department

Before-sales [email protected]

Estimated studiesSoftware Projipac

After-sales [email protected]

GuarantiesSpare parts

[email protected]+33351427042

Training

50

Formations

o PAC 6-01 : Nouveau clients , Descriptif

Gamme, accessoires, bonnes pratiques,

Dimensionner une PAC aérothermique en neuf

et en rénovation / 1 jours

o PAC 6-10 : Paramétrer la régulation sur une

PAC aérothermique (gestion des sondes,

applications services et clients) / 1 jour

o PAC 6-04 : Mettre en service, entretenir et

dépanner une PAC aérothermique / 2 jours

o PAC 6-14 : Réaliser un diagnostic de panne

frigorifique sur une pompe à chaleur

aérothermique / 2 jours

Questions ?