Heat Exchange Ventilation
Heat Exchange Ventilation
The principle . . . . . .
increase or decrease humidity
ventilation without loss of heat
recovery of thermal energy
potential to reduce air conditioningsystem requirements
Heat Exchange Ventilation
Heat Exchange Ventilation
• Fresh air ventilation increasingly required on internal rooms without window access
23ºC
18ºC 0ºC
Example: Heating Mode
• Helps prevent “sick building syndrome”
• Reclaims 20-50% of the energy lost by ventilation
• Improves energy efficiency, especially during hot and cold seasons
Heat Exchange Ventilation
Five models . . . . . .
VN-250SEVN-350SEVN-500SEVN-800SEVN-1KSAE
Heat Exchange Ventilation
Heat exchange Normal
Air volume (m3/h)
Input power (w)
Low High Extra high
Low High Extra high
External static (pa)
Noise level (dB)
Temperature exchange efficiency(%)
170 250 250 170 250 250
Ventilation ModeVN-250SEFan speeds
90 118 128 90 114 128
37 100 125 37 100 125
21 26 28 21.5 26.5 28
75 75 75 - - -
Heat Exchange Ventilation
Heat exchange Normal
Air volume (m3/h) Input power (w)
Low High Extra high
Low High Extra high
External static (pa)
Noise level (dB)
Temperature exchange efficiency(%)
240 350 350 240 350 350
Ventilation ModeVN-350SEFan speeds
132 149 178 131 145 176 43 90 155 43 90 155 23 30 33 23 30 33
79 75 75 - - -
Heat Exchange Ventilation
Heat exchange Normal
Air volume (m3/h)
Input power (w)
Low High Extra high
Low High Extra high
External static (pa)
Noise level (dB)
Temperature exchange efficiency(%)
310 500 500 310 500 500
Ventilation ModeVN-500SEFan speeds
162 202 244 161 196 243
33 85 165 33 85 165
23 31 35 24 33 36
79 75 75 - - -
Heat Exchange Ventilation
Heat exchange Normal
Air volume (m3/h)
Input power (w)
Low High Extra high
Low High Extra high
External static (pa)
Noise level (dB)
Temperature exchange efficiency(%)
575 800 800 575 800 800
Ventilation ModeVN-800SEFan speeds
367 399 445 362 392 438
35 55 90 35 55 90
33 37 38.5 33.5 37.5 39
76 75 75 - - -
Heat Exchange Ventilation
Heat exchange Normal
Air volume (m3/h)
Input power (w)
Low High Extra high
Low High Extra high
External static (pa)
Noise level (dB)
Temperature exchange efficiency(%)
810 1000 1000 810 1000 1000
Ventilation ModeVN-1KSAEFan speeds
367 399 445 362 392 438
35 55 90 35 55 90
33 37 38.5 33.5 37.5 39
76 75 75 - - -
Heat Exchange Ventilation
Supply air
Heat exchanger element
Return air
Control pcb
Heat Exchange Ventilation
Exhaust air
Heat exchanger element
Outside air
Heat Exchange Ventilation
Removable, washable air filters
Heat Exchange Ventilation
Heat exchanger element (removed for cleaning)
Heat exchanger element access door
Heat exchanger element
Heat Exchange Ventilation
Operation switch
230v 50Hz power supply
Airflow switch (low)
Airflow switch (high)
Damper changeover switch
Electrical connections
Heat Exchange Ventilation
Fan speed connections
CN8 + CN6 = high speed
CN7 + CN5 = extra high speed
Heat Exchange Ventilation
Operating conditions
Outdoor air Minimum -10oC
Maximum +40oC
Maximum RH 85% or less
Indoor air Minimum -10oC
Maximum +40oC
Maximum RH 85% or less
Heat Exchange Ventilation
Installation
Power supply 230 vac 50Hz 1 ph & ground
Supply cables 1.5mm2
Standards Installation should comply withall national and local electrical codes & standards as required
Isolation The power supply should be Isolated and the unit protected with the correctly sized isolator and mcb
Heat Exchange Ventilation
Installation
The unit is fitted with four support brackets which must be used for fixing the unit.
It is recommended that the unit is fixedusing 10mm or 12mm diameter drop rods
Ensure that adequate service access is provided for filter and heat exchangerelement removal
Heat Exchange Ventilation
Installation
Ductwork connections (supply and return)
VN 250SE 150mm diameter
VN 350SE 150mm diameter
VN 1KSAE 250mm diameter
VN 800SE 250mm diameter
VN 500SE 200mm diameter
All external ductwork must be insulated to prevent condensation
All external ductwork joints must be taped to prevent air leakage
Start up
Heat exchanger operation Check damper position is correct (towards control box)
Ventilation operation Check damper position is correct (away from control box)
Air flow switch Check fans operate in high and low speeds during both heat exchanger and ventilation modes
Heat Exchange Ventilation
Heat Exchange Ventilation
Heat Exchange Ventilation