Heartland Alliance Procurement Policy€¦ · W1 D123 W1 10 22'-21/4" 2'-1" 4'-0" 2'-1" 3'-11 2'-1"...
Transcript of Heartland Alliance Procurement Policy€¦ · W1 D123 W1 10 22'-21/4" 2'-1" 4'-0" 2'-1" 3'-11 2'-1"...
manske • dieckmann • thompsonarchitecture • interiors
MDT
A101
4619 N BroadwayChicago, IL 60640
773.561.1987www.mdtarch.com
Printed: 12/27/17
Heartland Health Outreach
Main Level Plan
Registered Professional Design Firm # 184.000792
5501 S Halsted StChicago Illinois 60621
RevIDIssued ForDate01
02
03
04
05
06
07
08
09
10
11
DD Review
Permit Submission
Permit Revisions 1
Bid Set
Addendum 1
VE
Issue for Construction
Bulletin 1
Bulletin 2
Pharmacy
Bulletin 3
3/16/17
4/3/17
7/10/17
7/10/17
8/2/17
8/16/17
8/31/17
10/5/17
10/5/17
10/12/17
12/27/17
W1
W1
W1 W1
W2
W2
W1
W1 W1W1
D11
1
D11
2
D11
3
D11
4
D11
5
D11
6
D11
7
D11
8
D11
9
D12
2
D124
D14
1
D12
0
D12
1
D109
D125
D12
7
D10
4
D10
5
D10
6
D10
3
D108
D143
D13
0D
129
D12
8
D140
D136
D138
D139
D137
D135
D14
5
D107
D14
2
D12
6
D100
W4
W3
W3
W3
W6
D14
7
W6
D132
D131
D134
D133
W5D101 D102
W6
D14
4
Refrigerator
Refrigerator
Wash / Dry
Wash / Dry
Ref
riger
ator
N
Refrigerator
11'-1/4" 11'-1/4"10'-113/4"
5'-
0"
9'-
6"
9'-
0"
13'-81/2"
6'-
2"
5'-
7"
5'-
1/4
"3
'-13
/4"
15'-101/4"
17'-
9" 5'-
0"
7'-
33
/4"
2'-
9"
12'-
0"
19'-101/4"
12'-
1"
10'-
81/
4"
5'-
0"
11'-
4"
10'-2" 10'-2" 10'-11/4"
9'-33/4"
5'-
1/4
"
14'-3/4"
6'-
3/4
"
17'-
11"
9'-
1/4
"
8'-
73
/4"
8'-
73
/4"
8'-
73
/4"
101'-41/4"
9'-91/
4"
69
'-1/
4"
100'-51/2"
32'-
63
/4"
8'-1/2"
43
'-13
/4"
7'-
3"
5'-6"
5'-1/4"
7'-51/4"
9'-
21/
4"
7'-
31/
4"
3'-
8"
3'-
81/
4"
8'-0"
15'-
81/
4"
5'-
1/4
"
7'-
1"
5'-0"
3'-111/2"
8'-0"
5'-0"
6'-
91/
2"
5'-
101/
4"
7'-
9"
8'-
71/
2"
5'-
11"
5'-
0"
7'-6" 7'-61/4"
3'-41/4"
39
'-10
1/4
"
8'-0"
9'-
61/
2"
12'-1/4"
15'-1"
16'-
5"
9'-113/4"
12'-
21/
4"
Eq
.3
'-0
"E
q.
3'-
0"
Eq
.
11'-1/4"
6'-0"
19'-
113
/4"
8'-
8"
3'-0"
6'-
91/
2"
4'-41/4"
6'-0"
4'-
0"
5'-
71/
2"
4'-0" 3'-9"
2'-43/4"
7'-111/2"
10'-63/4"
4'-6"
2'-1" 3'-0" 4'-23/4"
2'-1" 7'-23/4"
5'-0"
4'-73/4" 3'-0" 2'-53/4"
Eq. 3'-0" Eq.61/2" 3'-0" 2'-111/2"
7'-101/4"
10'-2"10'-2"10'-2"10'-2"
3'-0" Eq.Eq.3'-0" Eq.Eq.
10'-2"10'-2"
3'-0" Eq.Eq.
5'-
53
/4"
4'-31/2"
3'-
0"
3'-
0"
18'-61/4"
6'-
91/
2"
24'-101/4"
14'-61/2" 4'-1/4"
9'-
9"
19'-
0"
2'-91/4"
3'-0"
Eq
.E
q.
20
'-2"
11'-
21/
2"
5'-
9"
2'-1" 3'-11" 2'-1"
1'-6" 1'-61/4"
1A202
1A202
1A702
2A702
3A702
4A702
5A702
4A702
4A702
5A702
4A201
1A201
2A201
3A201
A603
15
16
14
13 A602
17
A602
5
7
8
6 A603
4
3A603
10
11
9
A603
15
13
14 A603
16
A603
2
3
4
1 A604
8
5
7
6 A604
5
8
6
7 A602
10
12
11 A602
9A602
12 A601
9
A604
17 A603
3
1
2
4 A602
12
10
11 A604
4
1
2
3 A605
5 A605
WT8 WT2a WT8 WT2a WT8 WT2a WT8 WT2a
WT2a WT2a WT2a
WT2aWT2a
WT2a
WT2a
WT2a
WT2a
WT2a
WT2a
WT2a
WT2a
WT2a
WT2a
WT2a
WT2a
WT2a
WT2aWT2a
WT2aWT2a
WT2a
WT2bWT2b
WT2a
WT2a
WT2a
WT2a
WT2a
WT2a
WT2a
WT2a
WT2a
WT2a
WT2a
WT2a
WT2a
WT2a WT2a
WT2a
WT2a
WT2a
WT2a
WT4d
WT4d
WT4d
WT2a WT2a
WT2a
WT3
WT2aWT2a
WT4c
WT4c
WT4c
WT3 WT5
WT5
RTU Unit located Above
WT2a
WT4a
WT4a
WT4a
WT4a
WT9
WT9
WT2b
WT6
WT6
WT6
WT6
WT6
WT1
WT1
WT2a
WT2a
WT2a
WT9
WT2a
WT4b
WT4b
WT2b
WT2a
WT2a
WT2a
WT2a
WT2a
WT2a
Ramp with slopeno greater than 1:20
WT2b
WT2a WT2b WT2a
Provide backing forintegrated wall panel
Provide backing forintegrated wall panel
Provide backing forintegrated wall panel
Provide backing forintegrated wall panel
Provide backing forintegrated wall panel
Provide backing forintegrated wall panel
Provide backing forintegrated wall panel
Provide backing forintegrated wall panel
Provide backing forintegrated wall panel
Providebacking forintegratedwall panel
Providebacking forintegratedwall panel
Provide backing forTelevision above
Provide backing forPharmacy Security
and IT panel
WT9
WT9
Under-counterfridge
Triage111
108 sq ft
Exam112
108 sq ft
Exam113
108 sq ft
Exam114
108 sq ft
Exam115
108 sq ft
Exam116
108 sq ft
Exam117
105 sq ft
Exam118
110 sq ft
Exam119
114 sq ft
Therapy / Exam136
123 sq ft
Therapy / Exam135
123 sq ft
Therapy131
80 sq ft
Therapy132
80 sq ft
Medical Director133
80 sq ft
Flex / Huddle134
80 sq ft
Restroom A120
45 sq ft
Restroom B121
45 sq ft
WC142
49 sq ft
WC137
40 sq ft
Pharmacy147
409 sq ftConference Room
143290 sq ft
Collection141
125 sq ft
Staff Room138
304 sq ft
Clinic Manager139
132 sq ftCase Managers140
52 sq ft
Care Team123
283 sq ft
Reception125
253 sq ft
Files /Copier
Mail / Printer145
Medicine Closet126
95 sq ft
Waiting Area110
627 sq ft
Entry100
179 sq ft
Water101
39 sq ft
IT130
49 sq ft
JC127
11 sq ft
CU128
20 sq ft
SU129
21 sq ft
Shower A104
75 sq ft
Shower B105
75 sq ftLaundry
10675 sq ft
Family Health Room103
74 sq ft
Electrical107
61 sq ft
LockersCorridor109
260 sq ft
Corridor124
461 sq ft
Corridor144
279 sq ft
Corridor145
94 sq ft
Corridor146
175 sq ft
Storage108
65 sq ft
Case Worker102
63 sq ft
Nurse Triage122
71 sq ft
Security100A
43 sq ft
W1 W1
D12
3
D11
0
22'-21/4"
4'-0"
2'-
1"
2'-1" 3'-111/2"
3'-0"2'-1"
3'-
0"
6'-
21/
4"
3'-
0"
11'-
93
/4"
2A202
2A202
1A702
2A702
2A702
5A702
WT2a
WT2b
WT9
Floor Plan Notes
1. Replace all existing CMU blockinfill from previous storefront withmetal studs and sheathinginsulation before applying newfacade.
2. Patch and repair exteriormasonry wall where any previouspenetrations were removed.
3. Grind & Tuckpoint all masonryexterior walls exposed to theelements.
4. On South and East walls wherebrick will remain exposed, applywaterproof coating for protectionfrom elements.
5. Existing Columns to be painted.
6. Provide Corner Guards on allexposed drywall corners.
7. Provide backing on all walls inthe IT room and where noted.
8. Provide backing where neededfor millwork.
11
SCALE: 3/16" = 1'-0"1 First Floor Plan
9/12/17
manske • dieckmann • thompsonarchitecture • interiors
MDT
A401
4619 N BroadwayChicago, IL 60640
773.561.1987www.mdtarch.com
Printed: 12/27/17
Heartland Health Outreach
Wall Types
Registered Professional Design Firm # 184.000792
5501 S Halsted StChicago Illinois 60621
RevIDIssued ForDate01
02
03
04
05
06
07
08
DD Review
Permit Submission
Bid Set
VE
Issue for Construction
Bulletin 2
Pharmacy
Bulletin 3
3/16/17
4/3/17
7/10/17
8/16/17
8/31/17
10/5/17
10/12/17
12/27/17
WT2a - extend to 6" above ceilingWT2b - extend to deck
Interior PartitionWT2 Plumbing WallWT3 Low WallWT4New Exterior Wall, non-bearingWT1
Existing masonry wall with new interior insulationWT6Furring WallWT5
WT4a - extend to underside of counterWT4b - extend to 3'-6"WT4c - extend to 4'-0"WT4d - extend to 5'-0"
Security WallWT7 Plumbing Wall - Exam RoomsWT8 Pharmacy WallWT9
61/4"
1'-2"73/4" 51/2"
1/4" 1/4"
47/8" 81/2"
51/8" 71/4" 47/8"
Continuous top track (25 ga)WT2a: at 9'-6"WT2b: at deck
Continuous bottom track (25 ga)
Continuous top track (25 ga)
Continuous bottom track (25 ga)
2x4 blockingCap
Continuous top track (25 ga)
Continuous bottom track (25 ga)
Continuous top track (25 ga)
Continuous bottom track (25 ga)
Spray foam sealed to deck
Spray foam sealed to deck
Existing exterior masonry bearing wall,repointed as necessary
5/8" Type X gypsum board
Continuous top track (25 ga)
Continuous bottom track (25 ga)
3 5/8" Steel studs @ 16" O.C., offset2" from masonry wall
2 1/2" Icynene Proseal Eco (MD-R-210)! - Class II Vapor Retarder! - R-value: R-12.25
Spray foam sealed to deck
Spray foam sealed to deck
8"x8"x16" Nominal glazed blockTrenwyth Astra-Glaze-SW+
9'-0" Typ.
Acoustic batt where shown on plan
Continuous top track (25 ga)
Continuous bottom track (25 ga) Continuous bottom track (25 ga)
Continuous top track (25 ga)
1/4" Bullet-resistant fiberglass
5/8" Type X gypsum board
3 5/8" Steel studs @ 16" O.C.
5/8" Type X gypsum board
5/8" Type X gypsum board
3 5/8" Steel studs @ 16" O.C.
5/8" Type X gypsum board
Acoustic batt where shown on plan
5/8" Type X gypsum board
3 5/8" Steel studs @ 16" O.C.
5/8" Type X gypsum board
5/8" Type X gypsum board
3 5/8" Steel studs @ 16" O.C., offset2" from masonry wall
2 1/2" Icynene Proseal Eco (MD-R-210)! - Class II Vapor Retarder! - R-value: R-12.25
5/8" Type X gypsum board
3 5/8" Steel studs @ 16" O.C.
WT6
Acoustic batt where shown on plan
5/8" Type X gypsum board
3 5/8" Steel studs @ 16" O.C.,staggered
5/8" Type X gypsum board
Continuous bottom track (25 ga)
5/8" Type X gypsum board
6" Steel studs @ 16" O.C.
5/8" Type X gypsum board
Continuous top track (25 ga)
9'-0" Typ. 9'-0" Typ. 9'-0" Typ.
1/4" Bullet-resistant fiberglass onWT4b only (Security desk at Entry)
Continuous bottom track(25 ga)
9'-0" Typ.
Acoustic batt whereshown on plan
5/8" Type X gypsum board
3 5/8" Steel studs @ 16" O.C.
5/8" Type X gypsum board
1/2" Plywood backing
Continuous top track (25 ga)
HEA
DPL
AN
BA
SE
UL # U419 - 1 hr
HEA
DPL
AN
BA
SE
HEA
DPL
AN
BA
SE
UL # U905 - 2hr
HEA
DPL
AN
BA
SE
Existing masonry bearing wall
HEA
DPL
AN
BA
SEH
EAD
PLA
NB
ASE
Notes1. Mold resistant drywall to be used in all wet spaces: bathrooms, showers, laundry, etc.
6" minimum
HEA
DPL
AN
BA
SE
6" minimum
HEA
DPL
AN
BA
SE
6" minimum
Not Used Updated
HEA
DPL
AN
BA
SE
2'-
0"
max.
2'-
0"
max.
08
08
MDT
4619 N Broadway
Chicago, IL 60640
773.561.1987
www.mdtarch.com
manske • dieckmann • thompson
architecture • interiors
Registered Professional Design Firm # 184.000792
HHO 5501 S Halsted St
5501 S Halsted St Chicago Illinois 60621
Date Issued For RevID
WMA Job# 17037-00
REVIEW03.31.2017
PERMIT04.03.2017
ELECTRICAL
SYMBOLS & NOTES
E001
BID06.28.2017
BULLETIN 312.20.2017
Refrigerator
Refrigerator
Wash / Dry
Wash / Dry
Ref
riger
ator
Refrigerator
FreezerRefrigerator
Roof Hatch
Painted Gyp. Board Typ.See Detail 2/A301
Under-counterfridge
Triage111
108 sq ft
Exam112
108 sq ft
Exam113
108 sq ft
Exam114
108 sq ft
Exam115
108 sq ft
Exam116
108 sq ft
Exam117
105 sq ft
Exam118
110 sq ft
Exam119
114 sq ft
Therapy / Exam136
123 sq ft
Therapy / Exam135
123 sq ft
Therapy131
80 sq ft
Therapy132
80 sq ft
Medical Director133
80 sq ft
Flex / Huddle134
80 sq ft
Restroom A120
45 sq ft
Restroom B121
45 sq ft
WC142
49 sq ft
WC137
40 sq ft
(Future)Pharmacy
147403 sq ft
Conference Room143
290 sq ft
Collection141
125 sq ft
Staff Room138
304 sq ft
Clinic Manager139
132 sq ft
Case Managers140
52 sq ft
Care Team123
283 sq ft
Reception125
253 sq ft
Files /Copier
Mail / Printer145
Medicine Closet126
95 sq ft
Waiting Area110
630 sq ft
Entry100
185 sq ft
Water101
39 sq ft
IT130
49 sq ft
JC127
11 sq ft
CU128
20 sq ft
SU129
21 sq ft
Shower A104
75 sq ft
Shower B105
75 sq ft
Laundry106
75 sq ft
Family Health Room103
74 sq ft
Electrical107
61 sq ft
LockersCorridor109
254 sq ft
Corridor124
461 sq ft
Corridor144
279 sq ft
Corridor145
94 sq ft
Corridor146
175 sq ft
Storage108
65 sq ft
Case Worker102
63 sq ft
Nurse Triage122
71 sq ft
Security100A
43 sq ft
Refrigerator
Refrigerator
Wash / Dry
Wash / Dry
Ref
riger
ator
Refrigerator
Under-counterfridge
Triage111
108 sq ft
Exam112
108 sq ft
Exam113
108 sq ft
Exam114
108 sq ft
Exam115
108 sq ft
Exam116
108 sq ft
Exam117
105 sq ft
Exam118
110 sq ft
Exam119
114 sq ft
Therapy / Exam136
123 sq ft
Therapy / Exam135
123 sq ft
Therapy131
80 sq ft
Therapy132
80 sq ft
Medical Director133
80 sq ft
Flex / Huddle134
80 sq ft
Restroom A120
45 sq ft
Restroom B121
45 sq ft
WC142
49 sq ft
WC137
40 sq ft
(Future)Pharmacy
147403 sq ft
Conference Room143
290 sq ft
Collection141
125 sq ft
Staff Room138
304 sq ft
Clinic Manager139
132 sq ft
Case Managers140
52 sq ft
Care Team123
283 sq ft
Reception125
253 sq ft
Files /Copier
Mail / Printer145
Medicine Closet126
95 sq ft
Waiting Area110
630 sq ft
Entry100
185 sq ft
Water101
39 sq ft
IT130
49 sq ft
JC127
11 sq ft
CU128
20 sq ft
SU129
21 sq ft
Shower A104
75 sq ft
Shower B105
75 sq ft
Laundry106
75 sq ft
Family Health Room103
74 sq ft
Electrical107
61 sq ft
LockersCorridor109
254 sq ft
Corridor124
461 sq ft
Corridor144
279 sq ft
Corridor145
94 sq ft
Corridor146
175 sq ft
Storage108
65 sq ft
Case Worker102
63 sq ft
Nurse Triage122
71 sq ft
Security100A
43 sq ft
L6
L6
L6
L6
L6
L6
L6
L6L6 L6
MDT
4619 N Broadway
Chicago, IL 60640
773.561.1987
www.mdtarch.com
manske • dieckmann • thompson
architecture • interiors
Registered Professional Design Firm # 184.000792
HHO 5501 S Halsted St
5501 S Halsted St Chicago Illinois 60621
Date Issued For RevID
WMA Job# 17037-00
REVIEW03.31.2017
PERMIT04.03.2017
ELECTRICAL POWER
AND SIGNAL PLAN
E100
BID06.28.2017
ADDENDUM 108.02.2017
ADDENDUM 208.18.2017
BULLETIN 209.29.2017
BULLETIN 312.20.2017
MIDMA
RKM11
UltraClav
e
Heartland Health Outreach
Chicago, Illinois
USABLE SQUARE FEET: 350
PROJECT # DATE:
MW18065-MW 01/17/19
DRAWN BY: REVIEWED BY:
SCALE: N.T.S.
MW ME
DESIGN SCHEMATIC
DATE