Heartland Alliance Procurement Policy€¦ · W1 D123 W1 10 22'-21/4" 2'-1" 4'-0" 2'-1" 3'-11 2'-1"...

6
manske • dieckmann • thompson architecture • interiors MDT A101 4619 N Broadway Chicago, IL 60640 773.561.1987 www.mdtarch.com Printed: 12/27/17 Heartland Health Outreach Main Level Plan Registered Professional Design Firm # 184.000792 5501 S Halsted St Chicago Illinois 60621 RevID Issued For Date 01 02 03 04 05 06 07 08 09 10 11 DD Review Permit Submission Permit Revisions 1 Bid Set Addendum 1 VE Issue for Construction Bulletin 1 Bulletin 2 Pharmacy Bulletin 3 3/16/17 4/3/17 7/10/17 7/10/17 8/2/17 8/16/17 10/5/17 10/5/17 10/12/17 12/27/17 W1 W1 W1 W1 W2 W2 W1 W1 W1 W1 D111 D112 D113 D114 D115 D116 D117 D118 D119 D122 D124 D141 D120 D121 D109 D125 D127 D104 D105 D106 D103 D108 D143 D130 D129 D128 D140 D136 D138 D139 D137 D135 D145 D107 D142 D126 D100 W4 W3 W3 W3 W6 D147 W6 D132 D131 D134 D133 W5 D101 D102 W6 D144 Refrigerator Refrigerator Wash / Dry Wash / Dry Refrigerator N Refrigerator 11'- 1/4" 11'- 1/4" 10'-11 3/4" 5'-0" 9'-6" 9'-0" 13'-8 1/2" 6'-2" 5'-7" 5'- 1/4" 3'-1 3/4" 15'-10 1/4" 17'-9" 5'-0" 7'-3 3/4" 2'-9" 12'-0" 19'-10 1/4" 12'-1" 10'-8 1/4" 5'-0" 11'-4" 10'-2" 10'-2" 10'-1 1/4" 9'-3 3/4" 5'- 1/4" 14'- 3/4" 6'- 3/4" 17'-11" 9'- 1/4" 8'-7 3/4" 8'-7 3/4" 8'-7 3/4" 101'-4 1/4" 9'-9 1/4" 69'- 1/4" 100'-5 1/2" 32'-6 3/4" 8'- 1/2" 43'-1 3/4" 7'-3" 5'-6" 5'- 1/4" 7'-5 1/4" 9'-2 1/4" 7'-3 1/4" 3'-8" 3'-8 1/4" 8'-0" 15'-8 1/4" 5'- 1/4" 7'-1" 5'-0" 3'-11 1/2" 8'-0" 5'-0" 6'-9 1/2" 5'-10 1/4" 7'-9" 8'-7 1/2" 5'-11" 5'-0" 7'-6" 7'-6 1/4" 3'-4 1/4" 39'-10 1/4" 8'-0" 9'-6 1/2" 12'- 1/4" 15'-1" 16'-5" 9'-11 3/4" 12'-2 1/4" Eq. 3'-0" Eq. 3'-0" Eq. 11'- 1/4" 6'-0" 19'-11 3/4" 8'-8" 3'-0" 6'-9 1/2" 4'-4 1/4" 6'-0" 4'-0" 5'-7 1/2" 4'-0" 3'-9" 2'-4 3/4" 7'-11 1/2" 10'-6 3/4" 4'-6" 2'-1" 3'-0" 4'-2 3/4" 2'-1" 7'-2 3/4" 5'-0" 4'-7 3/4" 3'-0" 2'-5 3/4" Eq. 3'-0" Eq. 6 1/2" 3'-0" 2'-11 1/2" 7'-10 1/4" 10'-2" 10'-2" 10'-2" 10'-2" 3'-0" Eq. Eq. 3'-0" Eq. Eq. 10'-2" 10'-2" 3'-0" Eq. Eq. 5'-5 3/4" 4'-3 1/2" 3'-0" 3'-0" 18'-6 1/4" 6'-9 1/2" 24'-10 1/4" 14'-6 1/2" 4'- 1/4" 9'-9" 19'-0" 2'-9 1/4" 3'-0" Eq. Eq. 20'-2" 11'-2 1/2" 5'-9" 2'-1" 3'-11" 2'-1" 1'-6" 1'-6 1/4" 1 A202 1 A202 1 A702 2 A702 3 A702 4 A702 5 A702 4 A702 4 A702 5 A702 4 A201 1 A201 2 A201 3 A201 A603 15 16 14 13 A602 17 A602 5 7 8 6 A603 4 3 A603 10 11 9 A603 15 13 14 A603 16 A603 2 3 4 1 A604 8 5 7 6 A604 5 8 6 7 A602 10 12 11 A602 9 A602 12 A601 9 A604 17 A603 3 1 2 4 A602 12 10 11 A604 4 1 2 3 A605 5 A605 WT8 WT2a WT8 WT2a WT8 WT2a WT8 WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2b WT2b WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT2a WT4d WT4d WT4d WT2a WT2a WT2a WT3 WT2a WT2a WT4c WT4c WT4c WT3 WT5 WT5 RTU Unit located Above WT2a WT4a WT4a WT4a WT4a WT9 WT9 WT2b WT6 WT6 WT6 WT6 WT6 WT1 WT1 WT2a WT2a WT2a WT9 WT2a WT4b WT4b WT2b WT2a WT2a WT2a WT2a WT2a WT2a Ramp with slope no greater than 1:20 WT2b WT2a WT2b WT2a Provide backing for integrated wall panel Provide backing for integrated wall panel Provide backing for integrated wall panel Provide backing for integrated wall panel Provide backing for integrated wall panel Provide backing for integrated wall panel Provide backing for integrated wall panel Provide backing for integrated wall panel Provide backing for integrated wall panel Provide backing for integrated wall panel Provide backing for integrated wall panel Provide backing for Television above Provide backing for Pharmacy Security and IT panel WT9 WT9 Under- counter fridge Triage 111 108 sq ft Exam 112 108 sq ft Exam 113 108 sq ft Exam 114 108 sq ft Exam 115 108 sq ft Exam 116 108 sq ft Exam 117 105 sq ft Exam 118 110 sq ft Exam 119 114 sq ft Therapy / Exam 136 123 sq ft Therapy / Exam 135 123 sq ft Therapy 131 80 sq ft Therapy 132 80 sq ft Medical Director 133 80 sq ft Flex / Huddle 134 80 sq ft Restroom A 120 45 sq ft Restroom B 121 45 sq ft WC 142 49 sq ft WC 137 40 sq ft Pharmacy 147 409 sq ft Conference Room 143 290 sq ft Collection 141 125 sq ft Staff Room 138 304 sq ft Clinic Manager 139 132 sq ft Case Managers 140 52 sq ft Care Team 123 283 sq ft Reception 125 253 sq ft Files / Copier Mail / Printer 145 Medicine Closet 126 95 sq ft Waiting Area 110 627 sq ft Entry 100 179 sq ft Water 101 39 sq ft IT 130 49 sq ft JC 127 11 sq ft CU 128 20 sq ft SU 129 21 sq ft Shower A 104 75 sq ft Shower B 105 75 sq ft Laundry 106 75 sq ft Family Health Room 103 74 sq ft Electrical 107 61 sq ft Lockers Corridor 109 260 sq ft Corridor 124 461 sq ft Corridor 144 279 sq ft Corridor 145 94 sq ft Corridor 146 175 sq ft Storage 108 65 sq ft Case Worker 102 63 sq ft Nurse Triage 122 71 sq ft Security 100A 43 sq ft W1 W1 D123 D110 22'-2 1/4" 4'-0" 2'-1" 2'-1" 3'-11 1/2" 3'-0" 2'-1" 3'-0" 6'-2 1/4" 3'-0" 11'-9 3/4" 2 A202 2 A202 1 A702 2 A702 2 A702 5 A702 WT2a WT2b WT9 Floor Plan Notes 1. Replace all existing CMU block infill from previous storefront with metal studs and sheathing insulation before applying new facade. 2. Patch and repair exterior masonry wall where any previous penetrations were removed. 3. Grind & Tuckpoint all masonry exterior walls exposed to the elements. 4. On South and East walls where brick will remain exposed, apply waterproof coating for protection from elements. 5. Existing Columns to be painted. 6. Provide Corner Guards on all exposed drywall corners. 7. Provide backing on all walls in the IT room and where noted. 8. Provide backing where needed for millwork. 11 SCALE: 3/16" = 1'-0" 1 First Floor Plan 9/12/17

Transcript of Heartland Alliance Procurement Policy€¦ · W1 D123 W1 10 22'-21/4" 2'-1" 4'-0" 2'-1" 3'-11 2'-1"...

Page 1: Heartland Alliance Procurement Policy€¦ · W1 D123 W1 10 22'-21/4" 2'-1" 4'-0" 2'-1" 3'-11 2'-1" 3'-0" 3'-0" 6'-2 1/4" 3'-0" 11'-9 3/4" 2 A202 2 A202 1 A702 2 A702 2 A702 5 A702

manske • dieckmann • thompsonarchitecture • interiors

MDT

A101

4619 N BroadwayChicago, IL 60640

773.561.1987www.mdtarch.com

Printed: 12/27/17

Heartland Health Outreach

Main Level Plan

Registered Professional Design Firm # 184.000792

5501 S Halsted StChicago Illinois 60621

RevIDIssued ForDate01

02

03

04

05

06

07

08

09

10

11

DD Review

Permit Submission

Permit Revisions 1

Bid Set

Addendum 1

VE

Issue for Construction

Bulletin 1

Bulletin 2

Pharmacy

Bulletin 3

3/16/17

4/3/17

7/10/17

7/10/17

8/2/17

8/16/17

8/31/17

10/5/17

10/5/17

10/12/17

12/27/17

W1

W1

W1 W1

W2

W2

W1

W1 W1W1

D11

1

D11

2

D11

3

D11

4

D11

5

D11

6

D11

7

D11

8

D11

9

D12

2

D124

D14

1

D12

0

D12

1

D109

D125

D12

7

D10

4

D10

5

D10

6

D10

3

D108

D143

D13

0D

129

D12

8

D140

D136

D138

D139

D137

D135

D14

5

D107

D14

2

D12

6

D100

W4

W3

W3

W3

W6

D14

7

W6

D132

D131

D134

D133

W5D101 D102

W6

D14

4

Refrigerator

Refrigerator

Wash / Dry

Wash / Dry

Ref

riger

ator

N

Refrigerator

11'-1/4" 11'-1/4"10'-113/4"

5'-

0"

9'-

6"

9'-

0"

13'-81/2"

6'-

2"

5'-

7"

5'-

1/4

"3

'-13

/4"

15'-101/4"

17'-

9" 5'-

0"

7'-

33

/4"

2'-

9"

12'-

0"

19'-101/4"

12'-

1"

10'-

81/

4"

5'-

0"

11'-

4"

10'-2" 10'-2" 10'-11/4"

9'-33/4"

5'-

1/4

"

14'-3/4"

6'-

3/4

"

17'-

11"

9'-

1/4

"

8'-

73

/4"

8'-

73

/4"

8'-

73

/4"

101'-41/4"

9'-91/

4"

69

'-1/

4"

100'-51/2"

32'-

63

/4"

8'-1/2"

43

'-13

/4"

7'-

3"

5'-6"

5'-1/4"

7'-51/4"

9'-

21/

4"

7'-

31/

4"

3'-

8"

3'-

81/

4"

8'-0"

15'-

81/

4"

5'-

1/4

"

7'-

1"

5'-0"

3'-111/2"

8'-0"

5'-0"

6'-

91/

2"

5'-

101/

4"

7'-

9"

8'-

71/

2"

5'-

11"

5'-

0"

7'-6" 7'-61/4"

3'-41/4"

39

'-10

1/4

"

8'-0"

9'-

61/

2"

12'-1/4"

15'-1"

16'-

5"

9'-113/4"

12'-

21/

4"

Eq

.3

'-0

"E

q.

3'-

0"

Eq

.

11'-1/4"

6'-0"

19'-

113

/4"

8'-

8"

3'-0"

6'-

91/

2"

4'-41/4"

6'-0"

4'-

0"

5'-

71/

2"

4'-0" 3'-9"

2'-43/4"

7'-111/2"

10'-63/4"

4'-6"

2'-1" 3'-0" 4'-23/4"

2'-1" 7'-23/4"

5'-0"

4'-73/4" 3'-0" 2'-53/4"

Eq. 3'-0" Eq.61/2" 3'-0" 2'-111/2"

7'-101/4"

10'-2"10'-2"10'-2"10'-2"

3'-0" Eq.Eq.3'-0" Eq.Eq.

10'-2"10'-2"

3'-0" Eq.Eq.

5'-

53

/4"

4'-31/2"

3'-

0"

3'-

0"

18'-61/4"

6'-

91/

2"

24'-101/4"

14'-61/2" 4'-1/4"

9'-

9"

19'-

0"

2'-91/4"

3'-0"

Eq

.E

q.

20

'-2"

11'-

21/

2"

5'-

9"

2'-1" 3'-11" 2'-1"

1'-6" 1'-61/4"

1A202

1A202

1A702

2A702

3A702

4A702

5A702

4A702

4A702

5A702

4A201

1A201

2A201

3A201

A603

15

16

14

13 A602

17

A602

5

7

8

6 A603

4

3A603

10

11

9

A603

15

13

14 A603

16

A603

2

3

4

1 A604

8

5

7

6 A604

5

8

6

7 A602

10

12

11 A602

9A602

12 A601

9

A604

17 A603

3

1

2

4 A602

12

10

11 A604

4

1

2

3 A605

5 A605

WT8 WT2a WT8 WT2a WT8 WT2a WT8 WT2a

WT2a WT2a WT2a

WT2aWT2a

WT2a

WT2a

WT2a

WT2a

WT2a

WT2a

WT2a

WT2a

WT2a

WT2a

WT2a

WT2a

WT2a

WT2aWT2a

WT2aWT2a

WT2a

WT2bWT2b

WT2a

WT2a

WT2a

WT2a

WT2a

WT2a

WT2a

WT2a

WT2a

WT2a

WT2a

WT2a

WT2a

WT2a WT2a

WT2a

WT2a

WT2a

WT2a

WT4d

WT4d

WT4d

WT2a WT2a

WT2a

WT3

WT2aWT2a

WT4c

WT4c

WT4c

WT3 WT5

WT5

RTU Unit located Above

WT2a

WT4a

WT4a

WT4a

WT4a

WT9

WT9

WT2b

WT6

WT6

WT6

WT6

WT6

WT1

WT1

WT2a

WT2a

WT2a

WT9

WT2a

WT4b

WT4b

WT2b

WT2a

WT2a

WT2a

WT2a

WT2a

WT2a

Ramp with slopeno greater than 1:20

WT2b

WT2a WT2b WT2a

Provide backing forintegrated wall panel

Provide backing forintegrated wall panel

Provide backing forintegrated wall panel

Provide backing forintegrated wall panel

Provide backing forintegrated wall panel

Provide backing forintegrated wall panel

Provide backing forintegrated wall panel

Provide backing forintegrated wall panel

Provide backing forintegrated wall panel

Providebacking forintegratedwall panel

Providebacking forintegratedwall panel

Provide backing forTelevision above

Provide backing forPharmacy Security

and IT panel

WT9

WT9

Under-counterfridge

Triage111

108 sq ft

Exam112

108 sq ft

Exam113

108 sq ft

Exam114

108 sq ft

Exam115

108 sq ft

Exam116

108 sq ft

Exam117

105 sq ft

Exam118

110 sq ft

Exam119

114 sq ft

Therapy / Exam136

123 sq ft

Therapy / Exam135

123 sq ft

Therapy131

80 sq ft

Therapy132

80 sq ft

Medical Director133

80 sq ft

Flex / Huddle134

80 sq ft

Restroom A120

45 sq ft

Restroom B121

45 sq ft

WC142

49 sq ft

WC137

40 sq ft

Pharmacy147

409 sq ftConference Room

143290 sq ft

Collection141

125 sq ft

Staff Room138

304 sq ft

Clinic Manager139

132 sq ftCase Managers140

52 sq ft

Care Team123

283 sq ft

Reception125

253 sq ft

Files /Copier

Mail / Printer145

Medicine Closet126

95 sq ft

Waiting Area110

627 sq ft

Entry100

179 sq ft

Water101

39 sq ft

IT130

49 sq ft

JC127

11 sq ft

CU128

20 sq ft

SU129

21 sq ft

Shower A104

75 sq ft

Shower B105

75 sq ftLaundry

10675 sq ft

Family Health Room103

74 sq ft

Electrical107

61 sq ft

LockersCorridor109

260 sq ft

Corridor124

461 sq ft

Corridor144

279 sq ft

Corridor145

94 sq ft

Corridor146

175 sq ft

Storage108

65 sq ft

Case Worker102

63 sq ft

Nurse Triage122

71 sq ft

Security100A

43 sq ft

W1 W1

D12

3

D11

0

22'-21/4"

4'-0"

2'-

1"

2'-1" 3'-111/2"

3'-0"2'-1"

3'-

0"

6'-

21/

4"

3'-

0"

11'-

93

/4"

2A202

2A202

1A702

2A702

2A702

5A702

WT2a

WT2b

WT9

Floor Plan Notes

1. Replace all existing CMU blockinfill from previous storefront withmetal studs and sheathinginsulation before applying newfacade.

2. Patch and repair exteriormasonry wall where any previouspenetrations were removed.

3. Grind & Tuckpoint all masonryexterior walls exposed to theelements.

4. On South and East walls wherebrick will remain exposed, applywaterproof coating for protectionfrom elements.

5. Existing Columns to be painted.

6. Provide Corner Guards on allexposed drywall corners.

7. Provide backing on all walls inthe IT room and where noted.

8. Provide backing where neededfor millwork.

11

SCALE: 3/16" = 1'-0"1 First Floor Plan

9/12/17

Page 2: Heartland Alliance Procurement Policy€¦ · W1 D123 W1 10 22'-21/4" 2'-1" 4'-0" 2'-1" 3'-11 2'-1" 3'-0" 3'-0" 6'-2 1/4" 3'-0" 11'-9 3/4" 2 A202 2 A202 1 A702 2 A702 2 A702 5 A702

manske • dieckmann • thompsonarchitecture • interiors

MDT

A401

4619 N BroadwayChicago, IL 60640

773.561.1987www.mdtarch.com

Printed: 12/27/17

Heartland Health Outreach

Wall Types

Registered Professional Design Firm # 184.000792

5501 S Halsted StChicago Illinois 60621

RevIDIssued ForDate01

02

03

04

05

06

07

08

DD Review

Permit Submission

Bid Set

VE

Issue for Construction

Bulletin 2

Pharmacy

Bulletin 3

3/16/17

4/3/17

7/10/17

8/16/17

8/31/17

10/5/17

10/12/17

12/27/17

WT2a - extend to 6" above ceilingWT2b - extend to deck

Interior PartitionWT2 Plumbing WallWT3 Low WallWT4New Exterior Wall, non-bearingWT1

Existing masonry wall with new interior insulationWT6Furring WallWT5

WT4a - extend to underside of counterWT4b - extend to 3'-6"WT4c - extend to 4'-0"WT4d - extend to 5'-0"

Security WallWT7 Plumbing Wall - Exam RoomsWT8 Pharmacy WallWT9

61/4"

1'-2"73/4" 51/2"

1/4" 1/4"

47/8" 81/2"

51/8" 71/4" 47/8"

Continuous top track (25 ga)WT2a: at 9'-6"WT2b: at deck

Continuous bottom track (25 ga)

Continuous top track (25 ga)

Continuous bottom track (25 ga)

2x4 blockingCap

Continuous top track (25 ga)

Continuous bottom track (25 ga)

Continuous top track (25 ga)

Continuous bottom track (25 ga)

Spray foam sealed to deck

Spray foam sealed to deck

Existing exterior masonry bearing wall,repointed as necessary

5/8" Type X gypsum board

Continuous top track (25 ga)

Continuous bottom track (25 ga)

3 5/8" Steel studs @ 16" O.C., offset2" from masonry wall

2 1/2" Icynene Proseal Eco (MD-R-210)! - Class II Vapor Retarder! - R-value: R-12.25

Spray foam sealed to deck

Spray foam sealed to deck

8"x8"x16" Nominal glazed blockTrenwyth Astra-Glaze-SW+

9'-0" Typ.

Acoustic batt where shown on plan

Continuous top track (25 ga)

Continuous bottom track (25 ga) Continuous bottom track (25 ga)

Continuous top track (25 ga)

1/4" Bullet-resistant fiberglass

5/8" Type X gypsum board

3 5/8" Steel studs @ 16" O.C.

5/8" Type X gypsum board

5/8" Type X gypsum board

3 5/8" Steel studs @ 16" O.C.

5/8" Type X gypsum board

Acoustic batt where shown on plan

5/8" Type X gypsum board

3 5/8" Steel studs @ 16" O.C.

5/8" Type X gypsum board

5/8" Type X gypsum board

3 5/8" Steel studs @ 16" O.C., offset2" from masonry wall

2 1/2" Icynene Proseal Eco (MD-R-210)! - Class II Vapor Retarder! - R-value: R-12.25

5/8" Type X gypsum board

3 5/8" Steel studs @ 16" O.C.

WT6

Acoustic batt where shown on plan

5/8" Type X gypsum board

3 5/8" Steel studs @ 16" O.C.,staggered

5/8" Type X gypsum board

Continuous bottom track (25 ga)

5/8" Type X gypsum board

6" Steel studs @ 16" O.C.

5/8" Type X gypsum board

Continuous top track (25 ga)

9'-0" Typ. 9'-0" Typ. 9'-0" Typ.

1/4" Bullet-resistant fiberglass onWT4b only (Security desk at Entry)

Continuous bottom track(25 ga)

9'-0" Typ.

Acoustic batt whereshown on plan

5/8" Type X gypsum board

3 5/8" Steel studs @ 16" O.C.

5/8" Type X gypsum board

1/2" Plywood backing

Continuous top track (25 ga)

HEA

DPL

AN

BA

SE

UL # U419 - 1 hr

HEA

DPL

AN

BA

SE

HEA

DPL

AN

BA

SE

UL # U905 - 2hr

HEA

DPL

AN

BA

SE

Existing masonry bearing wall

HEA

DPL

AN

BA

SEH

EAD

PLA

NB

ASE

Notes1. Mold resistant drywall to be used in all wet spaces: bathrooms, showers, laundry, etc.

6" minimum

HEA

DPL

AN

BA

SE

6" minimum

HEA

DPL

AN

BA

SE

6" minimum

Not Used Updated

HEA

DPL

AN

BA

SE

2'-

0"

max.

2'-

0"

max.

08

08

Page 3: Heartland Alliance Procurement Policy€¦ · W1 D123 W1 10 22'-21/4" 2'-1" 4'-0" 2'-1" 3'-11 2'-1" 3'-0" 3'-0" 6'-2 1/4" 3'-0" 11'-9 3/4" 2 A202 2 A202 1 A702 2 A702 2 A702 5 A702

MDT

4619 N Broadway

Chicago, IL 60640

773.561.1987

www.mdtarch.com

manske • dieckmann • thompson

architecture • interiors

Registered Professional Design Firm # 184.000792

HHO 5501 S Halsted St

5501 S Halsted St Chicago Illinois 60621

Date Issued For RevID

WMA Job# 17037-00

REVIEW03.31.2017

PERMIT04.03.2017

ELECTRICAL

SYMBOLS & NOTES

E001

BID06.28.2017

BULLETIN 312.20.2017

Page 4: Heartland Alliance Procurement Policy€¦ · W1 D123 W1 10 22'-21/4" 2'-1" 4'-0" 2'-1" 3'-11 2'-1" 3'-0" 3'-0" 6'-2 1/4" 3'-0" 11'-9 3/4" 2 A202 2 A202 1 A702 2 A702 2 A702 5 A702

Refrigerator

Refrigerator

Wash / Dry

Wash / Dry

Ref

riger

ator

Refrigerator

FreezerRefrigerator

Roof Hatch

Painted Gyp. Board Typ.See Detail 2/A301

Under-counterfridge

Triage111

108 sq ft

Exam112

108 sq ft

Exam113

108 sq ft

Exam114

108 sq ft

Exam115

108 sq ft

Exam116

108 sq ft

Exam117

105 sq ft

Exam118

110 sq ft

Exam119

114 sq ft

Therapy / Exam136

123 sq ft

Therapy / Exam135

123 sq ft

Therapy131

80 sq ft

Therapy132

80 sq ft

Medical Director133

80 sq ft

Flex / Huddle134

80 sq ft

Restroom A120

45 sq ft

Restroom B121

45 sq ft

WC142

49 sq ft

WC137

40 sq ft

(Future)Pharmacy

147403 sq ft

Conference Room143

290 sq ft

Collection141

125 sq ft

Staff Room138

304 sq ft

Clinic Manager139

132 sq ft

Case Managers140

52 sq ft

Care Team123

283 sq ft

Reception125

253 sq ft

Files /Copier

Mail / Printer145

Medicine Closet126

95 sq ft

Waiting Area110

630 sq ft

Entry100

185 sq ft

Water101

39 sq ft

IT130

49 sq ft

JC127

11 sq ft

CU128

20 sq ft

SU129

21 sq ft

Shower A104

75 sq ft

Shower B105

75 sq ft

Laundry106

75 sq ft

Family Health Room103

74 sq ft

Electrical107

61 sq ft

LockersCorridor109

254 sq ft

Corridor124

461 sq ft

Corridor144

279 sq ft

Corridor145

94 sq ft

Corridor146

175 sq ft

Storage108

65 sq ft

Case Worker102

63 sq ft

Nurse Triage122

71 sq ft

Security100A

43 sq ft

Refrigerator

Refrigerator

Wash / Dry

Wash / Dry

Ref

riger

ator

Refrigerator

Under-counterfridge

Triage111

108 sq ft

Exam112

108 sq ft

Exam113

108 sq ft

Exam114

108 sq ft

Exam115

108 sq ft

Exam116

108 sq ft

Exam117

105 sq ft

Exam118

110 sq ft

Exam119

114 sq ft

Therapy / Exam136

123 sq ft

Therapy / Exam135

123 sq ft

Therapy131

80 sq ft

Therapy132

80 sq ft

Medical Director133

80 sq ft

Flex / Huddle134

80 sq ft

Restroom A120

45 sq ft

Restroom B121

45 sq ft

WC142

49 sq ft

WC137

40 sq ft

(Future)Pharmacy

147403 sq ft

Conference Room143

290 sq ft

Collection141

125 sq ft

Staff Room138

304 sq ft

Clinic Manager139

132 sq ft

Case Managers140

52 sq ft

Care Team123

283 sq ft

Reception125

253 sq ft

Files /Copier

Mail / Printer145

Medicine Closet126

95 sq ft

Waiting Area110

630 sq ft

Entry100

185 sq ft

Water101

39 sq ft

IT130

49 sq ft

JC127

11 sq ft

CU128

20 sq ft

SU129

21 sq ft

Shower A104

75 sq ft

Shower B105

75 sq ft

Laundry106

75 sq ft

Family Health Room103

74 sq ft

Electrical107

61 sq ft

LockersCorridor109

254 sq ft

Corridor124

461 sq ft

Corridor144

279 sq ft

Corridor145

94 sq ft

Corridor146

175 sq ft

Storage108

65 sq ft

Case Worker102

63 sq ft

Nurse Triage122

71 sq ft

Security100A

43 sq ft

L6

L6

L6

L6

L6

L6

L6

L6L6 L6

MDT

4619 N Broadway

Chicago, IL 60640

773.561.1987

www.mdtarch.com

manske • dieckmann • thompson

architecture • interiors

Registered Professional Design Firm # 184.000792

HHO 5501 S Halsted St

5501 S Halsted St Chicago Illinois 60621

Date Issued For RevID

WMA Job# 17037-00

REVIEW03.31.2017

PERMIT04.03.2017

ELECTRICAL POWER

AND SIGNAL PLAN

E100

BID06.28.2017

ADDENDUM 108.02.2017

ADDENDUM 208.18.2017

BULLETIN 209.29.2017

BULLETIN 312.20.2017

Page 5: Heartland Alliance Procurement Policy€¦ · W1 D123 W1 10 22'-21/4" 2'-1" 4'-0" 2'-1" 3'-11 2'-1" 3'-0" 3'-0" 6'-2 1/4" 3'-0" 11'-9 3/4" 2 A202 2 A202 1 A702 2 A702 2 A702 5 A702

MIDMA

RKM11

UltraClav

e

Heartland Health Outreach

Chicago, Illinois

USABLE SQUARE FEET: 350

PROJECT # DATE:

MW18065-MW 01/17/19

DRAWN BY: REVIEWED BY:

SCALE: N.T.S.

MW ME

DESIGN SCHEMATIC

DATE

APPROVED

AutoCAD SHX Text
NEW
AutoCAD SHX Text
%%uTR#1
AutoCAD SHX Text
%%uCORRIDOR
AutoCAD SHX Text
NEW
AutoCAD SHX Text
%%uTR#2
AutoCAD SHX Text
NEW
AutoCAD SHX Text
%%uSTERILE/MECH
AutoCAD SHX Text
EXISTING WALL
AutoCAD SHX Text
NEW WALL
Page 6: Heartland Alliance Procurement Policy€¦ · W1 D123 W1 10 22'-21/4" 2'-1" 4'-0" 2'-1" 3'-11 2'-1" 3'-0" 3'-0" 6'-2 1/4" 3'-0" 11'-9 3/4" 2 A202 2 A202 1 A702 2 A702 2 A702 5 A702

®

AutoCAD SHX Text
ALL PLANS, DRAWINGS, SPECIFICATIONS, SKETCHES AND OTHER INSTRUMENTS OF SERVICE, INCLUDING ELECTRONIC MEDIA (COLLECTIVELY, THE "INSTRUMENTS OF SERVICE") ARE THE SOLE PROPERTY OF BENCO. BENCO RESERVES THE EXCLUSIVE COPYRIGHT AND LICENSE TO USE THE INSTRUMENTS OF SERVICE. ANY REPRODUCTION OR REUSE OF THE INSTRUMENTS OF SERVICE FOR ANY PURPOSE, INCLUDING BUT NOT LIMITED TO BIDDING, CONSTRUCTION AND ANY OTHER PURPOSE, IS STRICTLY PROHIBITED. BENCO DOES NOT REPRESENT THAT THE INSTRUMENTS OF SERVICE HAVE BEEN REVIEWED FOR COMPLIANCE WITH ANY ZONING OR LOCAL BUILDING CODES. BENCO DENTAL SPECIFICALLY EXCLUDES ALL INVOLVEMENT IN, RESPONSIBILITY FOR AND ADVICE REGARDING ANY LOCAL BUILDING CODES, ZONING APPLICATIONS AND/OR BUILDING USE ISSUES OF ANY KIND.