HEART RATE VARIABILITY Marco Altini, PhD
![Page 2: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/2.jpg)
Making it smaller
Maternal and fetal monitoring during
pregnancy Prediction of pregnancy complications
Labour detection
Load Data Scientist Bloomlife
![Page 3: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/3.jpg)
Cardiorespiratory Fitness Estimation Energy Expenditure Estimation
Activity Recognition
PhD Applied Machine Learning
BSc, MSc Computer Science Engineering
![Page 4: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/4.jpg)
Making it smaller
Heart Rate + Heart Rate Variability + Electrohysterography +
Blood Pressure Gestational hypertension prediction
Labour detection Preterm birth
Head of Data Science Bloom Technologies HRV4Training
![Page 5: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/5.jpg)
THIS TALK
Historically HRV analysis has been poorly standardized, leading to: • Difficulties in properly designing and
implementing studies • Difficulties in comparing studies
outcomes
5
![Page 6: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/6.jpg)
THIS TALK
The ease of access to HRV data today often obscures the complicated nature of understanding and correctly interpreting the information provided and underlying physiological processes Therefore the very nature of HRV itself may have led (or might lead in the future) to confusion for its use in applied research
6
![Page 7: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/7.jpg)
THIS TALK
The ease of access to HRV data today often obscures the complicated nature of understanding and correctly interpreting the information provided and underlying physiological processes Therefore the very nature of HRV itself may have led (or might lead in the future) to confusion for its use in applied research This talk is about trying to provide some clarity
7
![Page 8: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/8.jpg)
THIS TALK
• What’s Heart Rate Variability? (HRV) – Physiological mechanisms, definition
• How to collect data – Technology
• Best practices – Context, confounding factors
• What to do with the data – Experiment design
• Applications
8
![Page 9: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/9.jpg)
WHAT’S HRV?
Each heart beat is triggered by an electrical impulse that can be captured by an electrocardiogram (ECG), one of the most common ways to measure heart activity However, heart beats are not constant in frequency, when we talk about heart rate variability, we are interested in capturing the variability that occurs between beats
9
![Page 10: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/10.jpg)
BEAT TO BEAT VARIATION
Differences between beats are called RR intervals (the name derives from the fact that the ECG shape has been assigned letters to identify different parts, namely the QRS complex)
10
![Page 11: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/11.jpg)
WHY DO WE CARE?
11
![Page 12: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/12.jpg)
STRESS & HOMEOSTASIS
Homeostasis is about maintaining balance The body senses stress through its senses and sends information to the brain, which determines how to deal with it No matter the stressor, the body reacts in the same way
12
![Page 13: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/13.jpg)
CENTRAL NERVOUS SYSTEM
Changes in beat to beat variation reflect the output of the central autonomic network, which is responsible for our (visceral) response to stimuli (see Thayer et al.). HRV is mediated by neurons (with sympathetic and parasympathetic origin) and by the vagus nerve, however mainly dominated by parasympathetic (vagal) influence 13
![Page 14: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/14.jpg)
AUTONOMIC NERVOUS SYSTEM
Conducts impulses from the brain and spinal cord to smooth muscles, cardiac muscles, etc. Regulated by the hypothalamus, and in control of the fight or flight response Controls 80-90% of processes in the body Longer term mechanisms: circardian rhythm, body temperature, hormones Short term: respiration, baroreflex,
14
![Page 15: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/15.jpg)
VAGUS NERVE
Measure of parasympathetic activity, controls many organs, including the heart, and connects processes like respiration and blood pressure to the heart Instead of measuring directly the vagus nerve, we measure processes that the vagus nerve alters
15
![Page 16: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/16.jpg)
HRV AS A PROXY TO VAGAL TONE
HRV can capture changes in the ANS non-invasively, giving us insights into the body’s mental and physical abilities It does so by quantifying one of the main controllers of the ANS, which is the vagus nerve, a cranial nerve which brings information from the body to the brain The amount of vagal influence on the heart, vagal tone, can be measured by HRV
16
![Page 17: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/17.jpg)
TO SUM UP
The autonomic nervous system (ANS) controls and regulates many functions of our body and is in control of how our body reacts to stressors Heart Rate Variability (HRV) • Regulated by sympathetic /
parasympathetic branches of the ANS hence it provides insights into this control mechanism
17
![Page 18: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/18.jpg)
18
Higher HRV
Less physiologically stressed
Ready to perform
Lower HRV
More physiologically stressed
Tiredness
![Page 19: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/19.jpg)
19
Higher HRV
Less physiologically stressed
Ready to perform
Lower HRV
More physiologically stressed
Tiredness
Huge oversimplification
![Page 20: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/20.jpg)
MAIN POINTS TO COVER
• What’s Heart Rate Variability? (HRV) – Physiological mechanisms, definition
• How to collect data – Technology
• Best practices – Context, confounding factors
• What to do with the data – Experiment design
• Applications
20
![Page 21: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/21.jpg)
HOW TO COLLECT DATA
Electrocardiography (ECG): gold standard Chest strap + app: typically very accurate, recommend Polar H7/H10 (not all chest straps are equal) Photoplethysmography (PPG): HRV4Training, same as an ECG/Polar. Higher compliancy Wristbands, ear or arm sensors (also PPG): with some limitations Ballistocardiography (BCG): based on detecting body movement resulting from heart activity (e.g. mounted on your bed)
21
![Page 22: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/22.jpg)
A NOTE ON SENSORS
(I) consider them only if they either: - Comply to standards (e.g. bluetooth 4.0 heart rate profile)
which allow to collect basic information such as RR intervals
- Provide standard features such as rMSSD - Provide other ways to access basic information such as RR
intervals (if not the raw signal, ECG, PPG, BCG, etc.) Why is this important? Unfortunately most sensors are either locked behind proprietary software / apps or providing only custom metrics, hence they cannot be evaluated in their ability to do what they claim (can they actually measure HRV?), and they cannot be used by other apps
Even if they do send RR intervals and comply to standards, it does not mean that they do so accurately
22
![Page 23: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/23.jpg)
ECG
Basic signal processing: filtering, beat detection, feature computation
23
![Page 24: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/24.jpg)
CHEST STRAP + APP
Typically very accurate, recommend Polar H7 – we validated Polar H7 against full ECGs (healthy subjects)
24
![Page 25: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/25.jpg)
AdaptedfromTamuraetal.WearablePhotoplethysmographicSensors—PastandPresent
PPG
![Page 26: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/26.jpg)
AdaptedfromTamuraetal.WearablePhotoplethysmographicSensors—PastandPresent
PPG
![Page 27: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/27.jpg)
PPG SIGNAL PROCESSING
![Page 28: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/28.jpg)
PPG SIGNAL PROCESSING
![Page 29: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/29.jpg)
Choietal.Photoplethysmographysamplingfrequency:pilotassessmentofhowlowcanwegotoanalyzepulseratevariabilitywithreliability?(2017)
PPG SAMPLING FREQUENCY
![Page 30: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/30.jpg)
PPG SAMPLING FREQUENCY
Choietal.Photoplethysmographysamplingfrequency:pilotassessmentofhowlowcanwegotoanalyzepulseratevariabilitywithreliability?(2017)
not a badge of honor
![Page 31: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/31.jpg)
Liuetal.TowardsaSmartphoneApplicaPonforesPmaPonofpulsetransitPme(2015)
PPG INTERPOLATION
![Page 32: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/32.jpg)
Liuetal.TowardsaSmartphoneApplicaPonforesPmaPonofpulsetransitPme(2015)
PPG INTERPOLATION
![Page 33: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/33.jpg)
CAMERA VS ECG
![Page 34: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/34.jpg)
VALIDATED PPG
HRV4Training provides validated camera based measurements
34
![Page 35: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/35.jpg)
ECG vs PPG vs CHEST STRAP
From Plews et al. “Comparison of HRV recording with smart phone PPG, Polar H7 chest strap and electrocardiogram methods”
35
![Page 36: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/36.jpg)
OTHER PPG SENSORS: EAR, WRIST, ARM
36
![Page 37: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/37.jpg)
ANGEL SENSOR (RIP)
Hardware limitations?
37
![Page 38: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/38.jpg)
ANGEL SENSOR (RIP)
38
• Verynoisy
![Page 39: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/39.jpg)
ANGEL SENSOR (RIP)
39
• Verynoisy
![Page 40: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/40.jpg)
MIO ALPHA*
40
*andmanyothers:targePngadifferentapplicaPon(reliableHRduringexercise),toomuchfilteringforHRVanalysis
![Page 41: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/41.jpg)
VARIOUS PPG vs CHEST STRAP
Mio Alpha: case with too much averaging (note that it does capture some variability)
41
![Page 42: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/42.jpg)
KYTO EARCLIP
Kyto earclip: issues with higher HRV
42
![Page 43: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/43.jpg)
VARIOUS PPG vs CHEST STRAP
Kyto earclip: issues with higher HRV
43
![Page 44: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/44.jpg)
WRISTBANDS AND OTHER SENSORS
44
![Page 45: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/45.jpg)
WRISTBANDS AND OTHER SENSORS
45
![Page 46: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/46.jpg)
ZOOM HRV
46
Accurate when corrected for artifacts (measurement time limited to 3 minutes)
![Page 47: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/47.jpg)
ZOOM HRV
47
Accurate when corrected for artifacts (measurement time limited to 3 minutes)
![Page 48: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/48.jpg)
MAIN POINTS TO COVER
• What’s Heart Rate Variability? (HRV) – Physiological mechanisms, definition
• How to collect data – Technology
• Best practices – Context, confounding factors
• What to do with the data – Experiment design
• Applications
48
![Page 49: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/49.jpg)
CONFOUNDING FACTORS
AnumberofexternalfactorsareusuallycontrolledforinHRVresearch,includingtheintakeofnico%ne(Hayanoetal.,1990;SjobergandSaint,2011)andcaffeine(Sondermeijeretal.,2002)precedingdatacollecPon.CardioacPvemedica%onuse,includingsomeanPdepressantclasses(e.g.,tricyclics;Kempetal.,2010),someanPpsychoPcclasses(e.g.,clozapine;Cohenetal.,2001),benzodiazepines(Agelinketal.,2002),andanPhypertensives(Schroederetal.,2003)arealsousuallyaccountedfor,althoughthismaybesomewhatdifficultinpracPcewhentesPngpaPentpopulaPons.Otherfactorsthatareusuallyaccountedforincludethe%meofday(Massinetal.,2000;vanEekelenetal.,2004),levelsofhabitualalcoholuse(Quintanaetal.,2013a,b),physicalac%vitylevels(Briconetal.,2007;Soares-Mirandaetal.,2014),andage(O’Brienetal.,1986).Diges%onoffoodandwaterarelesscommonlyaccountedforinHRVresearch,butbothprovokeacoordinatedautonomicresponse.Forinstance,digesPngfoodhasbeenshowntoreduceparasympathePcacPvity,evenanhouragereaPnga500kcalmeal(Luetal.,1999).Evenexposuretofood-relatedcueselicitsasimilarresponse(Nederkoornetal.,2000),suggesPngaphysiologicalresponsetothean%cipa%onofameal.Conversely,missingameal(i.e.,fasPng)appearstohaveitsowncoordinatedeffectsonHRV(Piviketal.,2006),supporPngtherecommendaPonthatparPcipantsconsumealightmealapproximately2hbeforetheassessmentofHRV(Taketal.,2009).WaterconsumpPonhasalsobeenshowntoincreaseHF-HRVinparPcular(Routledgeetal.,2002),duetothevagalbufferingresponsetothepressoreffectprovokedbyhypo-osmoPcfluids(Scocetal.,2001).Notably,thisbufferingresponsetothepressoreffectisacenuatedinolderindividuals(Jordanetal.,2000)andnotobservedinthosewithcardiacvagaldenervaPon(Routledgeetal.,2002).InaddiPon,bothbladderandgastricdistensioncanalsohaveanappreciableinfluenceonHRV;thesehavebeenassociatedwithincreasesinbloodpressureandsympathePcoullow(FagiusandKarhuvaara,1989;Rossietal.,1998).However,papersonlyveryrarelyreportthatparPcipantswereaskedtoemptytheirbladderbeforeexperimentalparPcipaPon(Heathers,2014). Quintana et al.
49
![Page 50: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/50.jpg)
HOW DO WE CONTROL FOR THEM?
• Depends on research question, most commonly:
– Response to acute stressor (drug, food, activity, psychological, anything to challenge the ANS.) • pre-post measurement within individuals
– 24 hours recordings: affected by anything, less useful within individual (more like a between individual difference across macro-categories, like chronic disease and healthy) • Select similar subjects across groups?
– Progression of certain conditions, adaptation, etc.: less traditional (or less standardized) but more common methods (due to technological developments) such as long term / longitudinal, spot checks or night measurements • Create replicable situations w/ clear context
50
![Page 51: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/51.jpg)
BEST PRACTICES FOR LONGITUDINAL MEASUREMENS
Physiology (the ANS) responds acutely to basically anything (activity, food / drink intake, mental stress, etc.) – data needs to be contextualized to be correctly interpreted
• How/when to take the measurement
– Morning, still in bed?, etc.
• What type of measurement – Lying down, sitting?
• What metric to use?
– Time domain, frequency domain?
• Are 60 seconds enough?
• Other issues / recommendations
51
![Page 52: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/52.jpg)
HOW/WHEN TO MEASURE
• First thing after waking up – Relaxed physiological state – Limit all external stressors – Closest to what we do in research /
clinical studies – Highly correlated with night
measurements – Don’t read your email before the
measurement
52
![Page 53: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/53.jpg)
HOW/WHEN TO MEASURE
The inability of daily measurements to reflect underlying physiological stress was also shown recently by Mesquita et al.: Analyzing RMSSD from daily routine activities was not reliable, and therefore validity cannot be assumed • Acute stressors during the day prevent
reliability / repeatability • This is even assuming that rMSSD can be
captured correctly during daily activities, which is not to take for granted when using PPG based devices (artifacts)
53
![Page 54: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/54.jpg)
WHAT TYPE OF MEASUREMENT
• Lying down while still in bed – Limits other factors like not waiting enough
after standing up – Performed in clinical studies – Sitting/Standing also valid, however for
simplicity I’d recommend lying down unless your heart rate is very low (<40 bpm, in this case sitting or standing might be preferable)
– Going to another room also fine, take time to relax
– Highly discourage measuring at the lab / sport facilities / outside of your house
54
![Page 55: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/55.jpg)
WHAT METRICS TO USE
• HRV is not a single number • Use rMSSD or ln rMSSD (or HF) – Marker of parasympathetic activity (only
thing you can reliably measure). There is no clear sympathetic marker
– HF, LF, HF/LF or other frequency domain features require more time (and are computed differently by everyone, difficult to generalize/compare), more influenced by breathing / RSA
55
![Page 56: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/56.jpg)
WHY RMSSD OR HF?
The vagus nerve acts on receptors signaling nodes to modulate pulse on a beat to beat basis while sympathetic activity has different pathways with slower signaling hence beat to beat changes reflect parasympathetic activity (rMSSD). Vagal influence: very short latency (less than 1s), while sympathetic influence is too slow to result in beat to beat differences (4-20s, see Nunan et al.). 56
![Page 57: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/57.jpg)
ARE 60 SECONDS ENOUGH?
Yes.
57
![Page 58: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/58.jpg)
ARE 60 SECONDS ENOUGH?
Yes, but..
58
![Page 59: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/59.jpg)
MEASUREMENT FREQUENCY
• While 4-5 times/week will get you a good baseline, valuable information might be lost (e.g. weekly variability in measurements). Less than 3 measurements per week might be insufficient to get a reliable baseline
• Single morning spot check pre/post intervention …… ??
59
![Page 60: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/60.jpg)
MEASUREMENTS REPEATABILITY
60
![Page 61: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/61.jpg)
MEASUREMENTS REPEATABILITY
61
![Page 62: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/62.jpg)
MEASUREMENTS REPEATABILITY
62
![Page 63: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/63.jpg)
ARTIFACTS
HRV data is highly affected by artifacts, either in the measurement device (wrong beat detected, movement for PPG sensors), or in the actual data (ectopic beat, arrhythmias) that need to be handled properly. Check your app / device and ask what methods are used to deal with artifacts 63
![Page 64: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/64.jpg)
ECTOPIC BEATS
64
![Page 65: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/65.jpg)
ECTOPIC BEATS
rMSSD clean data: 79 ms rMSSD noisy data: 201 ms (ectopic beat) 65
![Page 66: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/66.jpg)
ECTOPIC BEATS
Identifying ectopic beats is done in clinical practice by removing RR intervals that differ more than 20 or 25% from the previous one, since that’s very uncommon and most likely is indicative of a problem (ectopic beat, noise, motion, etc.)
66
![Page 67: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/67.jpg)
IT HAPPENS WITH ALL THE SENSORS
Chest strap (H7)
67
![Page 68: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/68.jpg)
PPG
• Camera based (disruption caused by finger movement)
68
![Page 69: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/69.jpg)
ARTIFACTS
ECG recordings are the only ones that allow the researcher to see the QRS complex and hence the heart beats, leading to accurate identification of possible issues and meaningful correction In certain cases (certain arrhythmias) it is simply not possible to compute HRV
69
![Page 70: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/70.jpg)
MAIN POINTS TO COVER
• What’s Heart Rate Variability? (HRV) – Physiological mechanisms, definition
• How to collect data – Technology
• Best practices – Context, confounding factors
• What to do with the data – Experiment design
• Applications
70
![Page 71: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/71.jpg)
EXPERIMENT DESIGN
• Between subject – 24 hours measurements (typical medical
studies in the early days of HRV analysis) – Single spot check
• Within subject – Acute changes in response to a stressor
(pre/post) – Longitudinal data collection: spot checks
in the morning or night measurements 71
![Page 72: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/72.jpg)
EXPERIMENT DESIGN
Given high inter-individual variations and the complex interactions influencing HRV, within-subject designs are highly recommended Within-subject designs offer optimal experimental control, contribute to the elimination of individual differences in respiratory rates and reduce the impact of external factors such as medication, alcohol, smoking, etc. Quintana and Heathers et al.
72
![Page 73: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/73.jpg)
BETWEEN SUBJECT EXPERIMENTS
Typical studies in medical literature (40 years ago to now). Non-linear relationship when analyzing data across individuals • At lower HRs there is more time
between heartbeats and variability naturally increases.
73
![Page 74: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/74.jpg)
BETWEEN SUBJECT EXPERIMENTS
24 hours measurements: • Macro-differences in physiology between
specific medical conditions and healthy controls
• Dependent on physical activity behavior and other confounding factors
• Would speculate most differences between groups detectable by SDNN over 24 hrs is also captured by morning / night measurements of rMSSD or HF
74
![Page 75: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/75.jpg)
BETWEEN SUBJECT EXPERIMENTS
Spot check: • Single measurement to analyze differences in
vagal tone between conditions, for example: HRV between healthy pregnancies, hypertensive pregnancies, controls.
75Yangetal.PreeclampPcpregnancyisassociatedwithincreasedsympathePcanddecreasedparasympathePccontrolofhr.
![Page 76: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/76.jpg)
WITHIN SUBJECT EXPERIMENTS
• Acute HRV changes: day to day variations to acute stressors (or intra-day) – intense workout – getting sick – Travel – Meds – Food – etc.
• Longitudinal data: long term/chronic changes in baseline values – Adaptation to training / overtraining – Development of a chronic condition – Pregnancy approaching labour – etc.
76
![Page 77: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/77.jpg)
ACUTE STRESSORS
Most examples are shown from HRV4Training data – Real-life – Contextualized (but in real-life J) – Clear signal processing pipeline (artifacts,
etc.) – Covers many situations (training, travel,
alcohol intake, menstruation, getting sick, etc.)
– Sample size (for population derived analysis)
77
![Page 78: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/78.jpg)
HRV change following training
TRAINING EXAMPLE
![Page 79: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/79.jpg)
HRV change following training
TRAINING EXAMPLE
![Page 80: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/80.jpg)
The day after rest or easy trainings
Higher HRV
TRAINING EXAMPLE
![Page 81: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/81.jpg)
The day after average or intense trainings
Lower HRV
TRAINING EXAMPLE
![Page 82: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/82.jpg)
TRAINING EXAMPLE
![Page 83: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/83.jpg)
−8
−4
0
4
8
20 to
30
20 to
30
30 to
40
30 to
40
40 to
50
40 to
50
50 to
60
50 to
60
Age groups
HR
cha
nge
(%)
TrainingLow training loadHigh training load
HR change
−8
−4
0
4
8
20 to
30
20 to
30
30 to
40
30 to
40
40 to
50
40 to
50
50 to
60
50 to
60
Age groups
rMSS
D c
hang
e (%
)
HRV (rMSSD) change
TRAINING EXAMPLE
![Page 84: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/84.jpg)
TRAVEL EXAMPLE
![Page 85: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/85.jpg)
TRAVEL EXAMPLE
![Page 86: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/86.jpg)
ALCOHOL EXAMPLE
![Page 87: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/87.jpg)
GETTING SICK EXAMPLE
rMSSD HeartRate
![Page 88: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/88.jpg)
GETTING SICK EXAMPLE
rMSSD HeartRate
![Page 89: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/89.jpg)
GETTING SICK EXAMPLE
> 1 million data points from 6000 users
![Page 90: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/90.jpg)
ACUTE STRESSORS
Acute stressors are typically quite strong, and can be detected even when analyzed in isolation as we’ve just seen
However, we should remember that all of the above factors (and many others) act simultaneously on the ANS (-> collect contextual data, physiological measurements per se are pretty useless)
90
![Page 91: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/91.jpg)
LONGITUDINAL DATA COLLECTION
– Enabled by today’s technologies • Measurements can be taken in optimal
conditions (in terms of context and reductions of confounders, e.g. first thing in the morning). Much better than going to the lab (every day?) • Compliancy increases as measuring requires
less bulky technology / sensors (or no sensors at all)
– Powerful analysis: within-subject, longitudinal
91
![Page 92: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/92.jpg)
LONGITUDINAL DATA COLLECTION
Examples: - Progression of specific conditions,
healthy ones (e.g. pregnancy) as well as disease (typical reduction in vagal tone, see diabetic neuropathy)
- Adaptation to specific environments or activities: - Altitude adaptations (might be reflected
in the degree of the reduction in HRV) - Training block / overtraining
92
![Page 93: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/93.jpg)
EXAMPLE: night rMSSD during pregnancy
93
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●●
●
●●
●
●●
●
●
●
●
●
●
●●●
●
●●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●●
●
●
●
●
●
●
●
●
●
●
20
40
60
10 20 30 40Pregnancy week
rMSS
D (m
s)
Daily heart rate variability over pregnancy
●
●
●
●
●
●
●●
●
●●
●
●●
●
●
●
●
●
●
●
●
●
●
●●
●
●
●
●●
●
●
●
●
●
●
●●
●
●
●
●
●
●
●
●
●
●
●
●
●
●●●●
●
●
●●
●
●●
●
●
20
40
60
10 20 30 40Pregnancy week
rMSS
D (m
s)
Daily heart rate variability over pregnancy (night only)
●
●
●
●
●
●
●●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●●
●
● ●
●
●● ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●●●●
●
●
●
●
●●
●
●
●
●
20
40
60
10 20 30 40Pregnancy week
rMSS
D (m
s)
Daily heart rate variability over pregnancy, clean data
●
●●●
●
●
●●
●
●●
●●
●
●
●
●
●
●
●
●
●
●
●●
●
●
●
●
●
●
●
●
●
●
●
●
●
●●●●●
●
●
●●
●
●●
●
●
20
40
60
10 20 30 40Pregnancy week
rMSS
D (m
s)
Daily heart rate variability over pregnancy (clean data, night only)
![Page 94: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/94.jpg)
EXAMPLE: morning rMSSD and chronic load to predict injury risk in Crossfit
94
WilliamsS.etal."HeartRateVariabilityisaModeraPngFactorintheWorkload-InjuryRelaPonshipofCompePPveCrossFit™Athletes"JournalofSportsScienceandMedicine,2017
![Page 95: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/95.jpg)
EXAMPLE: morning rMSSD and chronic load to predict injury risk in Crossfit
95
WilliamsS.etal."HeartRateVariabilityisaModeraPngFactorintheWorkload-InjuryRelaPonshipofCompePPveCrossFit™Athletes"JournalofSportsScienceandMedicine,2017
![Page 96: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/96.jpg)
LONGITUDINAL DATA COLLECTION
As pretty much anything affects the ANS, collecting longitudinal data representative of vagal tone can provide insights in many complex mechanisms taking place in health and disease Provided that we have…..
96
![Page 97: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/97.jpg)
LONGITUDINAL DATA COLLECTION
• Accurate RR intervals • Artifact removal • Context / best practices • More context…..
(Valid data)
97
![Page 98: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/98.jpg)
MAIN POINTS TO COVER
• What’s Heart Rate Variability? (HRV) – Physiological mechanisms, definition
• How to collect data – Technology
• Best practices – Context, confounding factors
• What to do with the data – Experiment design
• Applications
98
![Page 99: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/99.jpg)
MEDICAL
Classic literature answering the question “does the HR dynamically respond?” Even just at the day / night level, or during challenging tasks The inability of the physiological self-regulatory systems to adapt to the current context and situation is associated with numerous clinical conditions
99
![Page 100: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/100.jpg)
MEDICAL
• Conditions where changes in HRV are associated with early manifestation
• Risk stratification
• Pharmacological responses
100
![Page 101: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/101.jpg)
SPORTS
Widespread for a simple reason: highly engaged user and easily quantifiable stressor (training) Faster feedback loop as well (performance, competition), with respect to other applications (e.g. aging J or progression of a specific disease)
101
![Page 102: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/102.jpg)
PSYCHOLOGY
Better self-regulation (higher vagal tone / HRV) linked to a series of emotional / mental states, for example more social engagement
102
![Page 103: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/103.jpg)
AND MORE
• Lifestyle
• Sleep
• Normal values
• Etc.
103
![Page 104: Heart rate variability, technology and applications](https://reader031.fdocuments.in/reader031/viewer/2022021923/5a6612f47f8b9ad5138b484b/html5/thumbnails/104.jpg)
104
HEART RATE VARIABILITY Marco Altini, PhD