HEALTH CARE - USG Boral · PDF fileHealth care Requirements & ... restricted corridors. Clean...
Transcript of HEALTH CARE - USG Boral · PDF fileHealth care Requirements & ... restricted corridors. Clean...
INTRODUCTION
Health care Requirements & Applications
USG BORAL HEALTHCARE
3
Non-Restricted
Patient care
Dietary & Laundry
Semi-Restricted
Restricted
No requirements
Easily cleanable, acoustic and lay-in
Smooth finish, scrubbable, non-absorptive, non perforated, durable, withstand cleaning with chemicalsWeigh at least 5 kg/sqm or CE grid or hold down clip to prevent the passage of particles from the cavity above the ceiling plane
Same as dietary & laundry areas + Non-reveal and non-textures tiles
Non-acoustic tiles, monolithic with no crack and no perforation.
Lobby, waiting room, rest room and non-restricted corridors
Clean utility/supply, nourishment, Patient rooms, pharmacy, central services, laboratories, nurse stations, work areas for storage and nurseries
Food preparation, food storage, ware washing & laundry areas
Airborne infection isolation rooms, clean corridors, central sterile supply space, NICU, radiographic room, Minor surgical rooms
Operating room, Sterile core and protective environmental rooms
USG Boral offers a wide range of high quality healthcare ceiling system that increase the aesthetic and functional value of your interiors within a modest ceiling budget.
USG Boral’s superior quality healthcare ceiling products are available in standard suspended ceiling systems such as exposed grid / concealed suspension system; custom-made metal ceiling is also available on request to meet the different requirements of architect specification design.
AREA REQUIREMENT ROOM TYPE
Non-Restricted
Patient care
Dietary & Laundry
Semi-Restricted
Restricted
No requirements
Easily cleanable, acoustic and lay-in
Smooth finish, scrubbable, non-absorptive, non perforated, durable, withstand cleaning with chemicalsWeigh at least 5 kg/sqm or CE grid or hold down clip to prevent the passage of particles from the cavity above the ceiling plane
Same as dietary & laundry areas + Non-reveal and non-textures tiles
Non-acoustic tiles, monolithic with no crack and no perforation.
Lobby, waiting room, rest room and non-restricted corridors
Clean utility/supply, nourishment, Patient rooms, pharmacy, central services, laboratories, nurse stations, work areas for storage and nurseries
Food preparation, food storage, ware washing & laundry areas
Airborne infection isolation rooms, clean corridors, central sterile supply space, NICU, radiographic room, Minor surgical rooms
Operating room, Sterile core and protective environmental rooms
AREA REQUIREMENT ROOM TYPE
USG BORAL CEILINGHEALTHCARE
Health care Applications
NP: not permitted X: Acceptable : in certain locations
4
Sonata Healthcare
Halcyon healthcare with back fleece
Cleanroom Class 100 (non-perforated)
Taiga Hygiene
Metal face
Sparta
Clip-in Plain Alum Ceiling
Lay-in Plain Alum Ceiling
NP NP
NP
NP
NP
NP
NP
NP
NP
NP
NP NP
NPNP
NPNP
AREA NON-RESTRICTED
PATIENT CARE AREAS
DIETARY &LAUNDRY
SEMIRESTRICTED RESTRICTED
X XX
X
X X X
X
X
X X
X X
X X
X X
X X
USG BORAL HEALTHCARE CLEANROOM CEILING
5
FUNCTIONAL PROPERTIES
CLEANROOM DEFINITION
CLEANROOM STANDARDS
• Define the space• Acoustical Control• Fire protection + smoke control• Cleanroom / Pressure control rooms (Lab, Data rooms)• Hygiene (kitchens / hospitals)• Moisture control (kitchens / toilets)• Anti-microbial features (hospitals)
Cleanroom is an environment • Typically used in manufacturing, pharmaceutical products, scientific research, aerospace• Engineering applications with a low level of environmental pollutants such as dust, airborne microbes, aerosol particles, and chemical vapors• A cleanroom has a controlled level of contamination that is specified by the number of particles per cubic meter at a specified particle size. • To give perspective, the ambient air outside in a typical urban environment contains 35,000,000 particles per cubic meter in the size range 0.5 ųm and larger in diameter, corresponding to an ISO 9 cleanroom• An ISO 1 cleanroom allows no particles, if only 2 particles 0.2 ųm and per cubic meter• Micrometer (ųm) is a metric measurement unit of length
• Federal Standard 209E was superseded by the new ISO 14644-1 international standards. References to FS209E are still used• The “cleanest” cleanroom FS209E is referred to as Class 1 equals to ISO Class 3• Most common, ISO Class 5 equals to FS209E Class 100• The “dirtiest” cleanroom is ISO Class 9 equals to FS209E Class 1,000,000
ISO CLASS 1
ISO CLASS 2
ISO CLASS 3
ISO CLASS 4
ISO CLASS 5
ISO CLASS 6
ISO CLASS 7
ISO CLASS 8
ISO CLASS 9
10
100
1000
10000
100 000
1000000
2
24
237
2370
23700
237000
10
102
1020
10200
102000
4
35
352
3520
35200
352000
3520000
35200000
8
83
832
8320
83200
832000
8320000
29
293
2930
29300
293000
Class 1
Class 10
Class 100
Class 1000
Class 10 000
Class 100000
Class 1000000
ISO CLASS MAXIMUM NUMBER OF PARTICLES IN AIR US FEDERALSTANDAD 209E
PARTICLE SIZE
(Particles in each cubic metre equal to or greater than the specified size)
>0.1ųm >0.2ųm >0.3ųm >0.4ųm >0.5ųm >0.6ųm
USG BORAL CEILINGHEALTHCARE CLEANROOM
6
CLEANROOM DESIGN Considerations / Recommendations
ASTM D2486
ASTM D3273 / ASTM D3274
ASTM D4828
FS 209E
ISD 14644-1
UL 2818
Scrubality (min 1500 scrub Cycle/min
Mold Growth(Rate 1-10)
Washability(Min 1500 Wash Cycle/MIN)
Cleanroom Class (Class 1- 100,000)
Cleanroom Class (Class 1- 9)
Low VOC (Green Guard)
>1500
10(No Growth)
>1500
N.A
Class 5
<9ųg/m3
>1500
10
>1500
N.A
Class 5
<9ųg/m3
>1500
10
>1500
N.A
Class 5
<9ųg/m3
>1500
10
>1500
N.A
Class 5
<9ųg/m3
>1500
10
>1500
10M-100M
Class 5
<9ųg/m3
>1500
10
>1500
N.A
N.A
<9ųg/m3
>1500
10
>1500
N.A
Class 5
N.A
STANDARDSONATAHEALTHCARE
CLEANROOMNON PERFORATED(MIDDLE EAST)
CLEANROOMNON PERFORATED(USG) METAL FACE
HALCYON HEALTHCARE
TAIGA HYGIENE SPARTA
CLASSIFICATION OF LABORATORIES
TEST COMPLIANCES
• PHYSICAL CONTAINMENT LEVEL 1 (PC1)A Physical Containment Level 1 laboratory is suitable for work with microorganisms where the hazard levels are low, and where laboratory or facility personnel can be adequately protected by standard laboratory practice. The organisms used should generally be classified as Risk Group 1. Specimens that have been inactivated or fixed may be handled in PC1 facilities
• PHYSICAL CONTAINMENT LEVEL 2 (PC2)A Physical Containment Level 2 laboratory is suitable for work with material likely to contain microorganisms that are classified as Risk Group 2 microorganisms. If working with specimens containing microorganisms transmissible by the respiratory route or if the work produces a significant risk to humans or the environment from the production of infectious aerosols
COMPARISON CHART HEALTHCARE - CLEANROOM TILES
• Low VOC Emission (Green Guard Gold Certification) per UL 2818• ISO Clean Room Class 100 per FS 209E and Class 5 as per ISO 14644-1• Anti Microbial resistance per ASTM D3273 (Mold growth) and classified per ASTM D3274• Scrubbability per ASTM D2486• Washability per ASTM D4828
PRODUCT INFORMATION
PRODUCT INFORMATION
APPLICATION
APPLICATION
USG BORAL HEALTHCARE CLEANROOM CEILING
7
SONATA HEALTHCARE
• Water-repellent membrane-top & bottom surface• Durable and cleanable• High NRC (0.7) High CAC(37 dB)• High LR (0.89)• Low-VOC emissions • High Impact and scratch resistance• Surface Washable • Antimicrobial treatment
• Executive Offices and Conference rooms• Reception areas and Lobbies• Corridors• Dining rooms, kitchens and food-prep areas• Patient Rooms• Nurse Stations
CLEAN ROOM™ NON-PERFORATED
• Embossed, vinyl laminated face with sealed back and edges Firecode basemat • Clean room non-perforated finish• Class 100 (FS 209E) • Class 5 as per ISO cleanroom standard 14644-1• Washable & scrubbable resistance• High humidity resistant and anti-mold, mildew growth
• Sterile rooms• Laboratories• Food/ beverage processing • Emergency rooms• Toilet/Wet rooms• Operating/MRI rooms• Surgical Rooms• Airborne Infection Isolation Rooms
USG BORAL HEALTHCARE CEILING
METAL FACE™
• Embossed, vinyl laminated face aluminum foil back Fire rated• Firecode base-mat• Coordinates visually with Clean room perforated finish• NRC 0.55, CAC 37 • Washable & scrubbable resistance• Resistance to corrosion, soiling, humidity and chlorine vapor
• HIGH Humidity Areas• Laboratories/pharmacies• Nurseries• Corridors/Lobbies• Certain Patient Care area – Waiting rooms• Offices
LOUNA
• Fiber Glass Substrate finished with monolithic Fiber Glass scrim• High NRC (up to 1) • High LR (0.88)• Low-VOC emitting panel solution.• Durable and safely cleaned • High Impact and scratch resistance• Washable & Scrubbable finish
• Waiting Rooms, Nurses stations• Receptions & Lobby Areas
SPECIFICATIONSSYSTEM USG LI 200 LAY-IN
METAL CEILINGS
8
PRODUCT INFORMATION
PRODUCT INFORMATION
APPLICATION
APPLICATION
TAIGA HYGIENE
• Smooth Plain• Taiga Hygiene has been developed to meet the most stringent demand on hygiene and clean ability• Special fungicide treatment • Antimicrobial additive on the face and the back surface• Resistance against the growth of mold and mildew• Scrubbable
• Consulting/Patient/treatment Rooms• Clinics / Laboratories• Work Area for Storage
SPARTA
• PVC Laminated• Aluminum Foil backing (vapor barrier) • Panel stays cleaner longer • Washable Vinyl facing • Scrub resistant
• Laboratories• Leisure/ IT Room• Toilet/Wet Areas
9
USG BORAL HEALTHCARE CEILING
PRODUCT INFORMATION
PRODUCT INFORMATION
APPLICATION
APPLICATION
USG BORALHEALTHCARE CEILING
SPECIFICATIONSSYSTEM USG LI 200 LAY-IN
METAL CEILINGS
PRODUCT INFORMATION
TYPES (CLIP-IN & LAY-IN)
SIZES (SQUARE; RECTANGULAR; PLANK)
METAL PLAIN LAY-IN/CLIP-IN
• Powder Coating Technology• Cleanable• Durable • Antibacterial paint• Cool Shade - innovative and sustainable way to reduce temperatures and energy consumption
300 x 300 MM600 x 600 MM1200 x 1200MM
300 x 1200 MM300 x 1500 MM600 x 1200MMOthers….
10
STO
RA
GE
AR
EA
www.usgboral.comwww.usg.comwww.usgdesignstudio.com
USG Middle East Ltd.
Dammam, Saudi ArabiaTel: +966 13 812 0995Fax: +966 13 812 1029e-mail: [email protected] [email protected]
Jeddah, Saudi ArabiaTel: +966 12 639 2172 +966 12 691 0251Fax: +966 12 682 3711e-mail: [email protected]
Riyadh, Saudi ArabiaTel: +966 11 291 8351 +966 11 291 8923Fax: +966 11 291 8894e-mail: [email protected]
Dubai, U.A.E.Tel: +971 4 379 0808Fax: +971 4 388 1305e-mail: [email protected]
Manama, BahrainTel: +973 17 581 596Fax: +973 17 581 597e-mail: [email protected]
Beirut, LebanonTel: + 961 4 547081/2/3/4Fax: + 961 4 547085e-mail: [email protected]
Doha, QatarTel: +974 44 318 387Fax: +974 44 982 165e-mail: [email protected]
Istanbul, TurkeyTel: +90 216 290 28 05Fax: +90 216 290 28 05e-mail: [email protected]
USG Boral reserves the right to change specifications or design and supply products which may differ from those described and illustrated without notice and without liability. All weights and measures are nominal.