Head and Neck Palpation Trainer - KYOTO KAGAKUHead and Neck Palpation Trainer Instruction Manual...
Transcript of Head and Neck Palpation Trainer - KYOTO KAGAKUHead and Neck Palpation Trainer Instruction Manual...
Contents● Before you start
● PreparationOpening the storage case
Do not mark on the model and other compo-nents with pen nor leave printed materials in contact with the surface.Ink marks on the models cannot be removed.
Caution
Set includes/Dos and Don’ ts ・・・・・・・・
・・・・・・・・・・・
P.1
P.2
● Training
● After Training
Sites for Palpation
Swallowing movement
・・・・・・・・・・・・・・・
・・・・・・・・・・・・
P.3
・・・・・・・・・・・・・・・・・ P.4
P.3
MW30
Head and Neck Palpation Trainer
InstructionManual
Head and Neck Palpation Trainer for Training and OSCE
11412-000
11412-100
Product Supervision :Junji Otaki,Professor and Acting Chief of the Center,Center for Medical Education, Hokkaido University
1
Before you start Dos and Don’ts
Materials of the Trainer are special composi-tions of soft resin, and carries a certain amount of weight. Do not drop from tall spaces as strong impact can damage the Trainer
● Handle with care
Discoloration happens naturally over time. This will not affect the use of the product.
Long period of pressure on material could cause material to change shape
Make sure to store Trainer with case in upright position
● Do not use pen or ink on Trainer
When used on the Trainer, pen or ink will be absorbed by the material and can not be removed
● Wipe the Trainer with water or detergent
● Possible discoloration
Prevent any printed material from touching the surface of Trainer
● Do not place any printed material on surface of the Trainer
Prevent from exposing heat, humidity, and direct sunlight when storing after use. This is to prevent material from deterioration and damages.
Being in contact with other plastic or resin products could cause chemical reaction and/or material deterioration. Always store in the case after use.
Wipe stains or dirt with water or detergent. Do not use thinners or any liquid containing organic solvent.
● Store the Trainer in a cool, dry place
● Do not let the Trainer be in contact with other plastic or resin products during storage
● Do not lay flat during storage
1
1
a
a a
b
b
Set includes
Before your first use, ensure that you have all components listed below.
(storage case attached)
Instruction manual
Head and neck manikin
Talcum Powder
2
1
a
b(storage case attached)
Instruction manual
Head and neck manikin(type A ・type B)
Talcum Powder
Set includes
a
b
● Head and Neck Palpation Trainer ● Head and Neck Palpation Trainer for training and OSCE
Dos and Don’ts
●Do not store printed material or other item together with model
2
Preparation
1 Opening the case
Opening the storage case
●Head and neck manikin is attached to the storage case at the bottom
1. Open zipper on top from both sides to open lid.
2. Open flap in front, which is fastened with velcro,and open zipper at the bottom from both sidesto fully open the case.
3. Once opened, fold storage case flaps behind manikin to start training.
caution : always use/store the case in upright position
3
Training
1 Sites for Palpation
2 Swallowing Movement
Palpation of cervical lymph nodes
By moving the lever on the back up and down, a swallowing movement is simulated
Examination of salivary gland
Examination ofthyroid gland
● Head and Neck Palpation Trainer
● Head and Neck Palpation Trainer for training and OSCE
Type A
Leftside
Pre-auricular nodesposterior auricular nodesSuperficial cervical nodesSupraclavicular nodes
Rightside
Leftside
Rightside
Superficial cervical nodesSubmandibular nodesPosterior cervical nodesThyroid gland
Superficial cervical nodesPosterior cervical nodesSubmental nodesSubmandibular nodes
Deep cervical nodesSubclavicular (Infraclavicular) nodesSubmandibular nodes
Type B
11 sites
2 sites
1 sites
posterior auricular nodes
Pre-auricular nodes
Parotid gland
Tonsillar nodes
Submandibular nodes
Submandibular gland
Submental nodes
Thyroid gland
Supraclavicular nodes
Subclavicular (Infraclavicular) nodes
Occipital nodes
Superficial cervical nodes
Posterior cervical nodes
Deep cervical nodes
Sternocleidomastoid
4
After Training
1 After training1. Wipe stains with wet tissue or a wet towel with added washing liquid.
2. Dry completely and add talcum powder to the surface of the manikin.
3. Open the folded flaps of storage case, raise flaps and close the zipper at the bottom.
Attention : Head and neck manikin is attached to the storage case. Always remember to store case in an upright position. Do not enclose anything else with the manikin inside the case.
5. Close the top lid, pull and fasten zipper.
4. Fasten the velcro on front flap.
Do not mark on the model and other components with pen nor leave printed materials in contact with the surface. Ink marks on the models cannot be removed.Caution
■ (World Wide)
The contents of the instruction manual are subject to change without prior notice.No part of this instruction manual may be reproduced or transmitted in any form without permission from the manufacturer. Please contact the manufacturer for extra copies of this manual which may contain important updates and revisions. Please contact the manufacturer with any discrepancies in this manual or product feedback. Your cooperation is greatly appreciated.
For inquiries and service, please contact your distributor or KYOTO KAGAKU CO., LTD.
2018.11
e
■
Kyoto Kagaku America Inc.