HDMI Test Solutions QPHY-HDMI - cdn.teledynelecroy.comHigh Definition Multimedia Interface (HDMI)...

4
Key Features Compliant with Version 1.4a of the HDMI Compliance Test Specification Dedicated signal pull-up termination provided by TF-HDMI-3.3V enables full bandwidth testing using cables Simple and easy-to-use automated testing Powerful and flexible analysis tools offer unmatched insight for diagnosing and solving elusive problems Support for all clock rates described in Version 1.4a of the specification Connection diagrams help to make sure that you get the right setup on the first try QualiPHY report generation creates comprehensive reports with all pertinent test information QPHY-HDMI provides a highly automated and easy-to-use solution for HDMI transmitter testing in accordance with Version 1.4a of the HDMI Compliance Test Specification. HDMI Test Solutions QPHY-HDMI The QPHY-HDMI software package for the WaveMaster/SDA/DDA 8 Zi/Zi-A Series of oscilloscopes provides a concise set of validation/ verification and debug tools written in accordance with version 1.4a of the High Definition Multimedia Interface (HDMI) electrical test specification. HDMI test modes cover amplitude, timing and jitter parameters. In addi- tion to standard eye pattern and jitter tests for HDMI, the SDA real-time test equipment platform provides a complete set of amplitude and jitter measurements, as defined in the HDMI specification. This combination of measurements makes QPHY-HDMI a cost-effective, compelling HDMI solution. Once a problem is detected, all of the power SDA tools are at your disposal to help find the root cause.

Transcript of HDMI Test Solutions QPHY-HDMI - cdn.teledynelecroy.comHigh Definition Multimedia Interface (HDMI)...

  • Key Features• Compliant with Version 1.4a of the HDMICompliance TestSpecification

    • Dedicated signal pull-uptermination provided by TF-HDMI-3.3V enables full bandwidth testing using cables

    • Simple and easy-to-useautomated testing

    • Powerful and flexible analysistools offer unmatched insight for diagnosing and solvingelusive problems

    • Support for all clock rates described in Version 1.4a of the specification

    • Connection diagrams help tomake sure that you get the right setup on the first try

    • QualiPHY report generationcreates comprehensive reports with all pertinent test information

    QPHY-HDMI provides a highlyautomated and easy-to-use solution for HDMI transmittertesting in accordance withVersion 1.4a of the HDMICompliance Test Specification.

    HDMI Test SolutionsQPHY-HDMI

    The QPHY-HDMI software package

    for the WaveMaster/SDA/DDA

    8 Zi/Zi-A Series of oscilloscopes

    provides a concise set of validation/

    verification and debug tools written in

    accordance with version 1.4a of the

    High Definition Multimedia Interface

    (HDMI) electrical test specification.

    HDMI test modes cover amplitude,

    timing and jitter parameters. In addi-

    tion to standard eye pattern and jitter

    tests for HDMI, the SDA real-time

    test equipment platform provides

    a complete set of amplitude and

    jitter measurements, as defined

    in the HDMI specification. This

    combination of measurements

    makes QPHY-HDMI a cost-effective,

    compelling HDMI solution.

    Once a problem is detected, all

    of the power SDA tools are at your

    disposal to help find the root cause.

  • 2

    This image is showing a measurement of VL level (Test 7–2). C1is triggered at the end of an H-L-L-L bit sequence. F2 is a zoom onthe last L-L bits. P3 is the most frequent level of those L-L bits.

    This image is a measure of Clock Rise Time (Test 7–4). F4 is theClock. F1 is the histogram of F4 vertical levels. The two peaks correspond to base and top, they are used to compute the 20% and 80% levels. Z1 is a zoom of F4 showing the computed levels. P6 is a measure of F4 rise time at these levels. F2 is thehistogram of P6 and P7 is the mode of F2, final measure asspecified by the standard.

    This image is a measure of the Eye Diagram (Test 7–10). The eye is validated against the mask as defined by the standard.

    QPHY-HDMI Makes Compliance Testing Easy

    Typically, compliance testing is a very difficult task.

    The user must make the necessary connections between

    the oscilloscope and the device under test, manually

    configure the oscilloscope for the appropriate measure-

    ment, perform the test procedure as specified by the

    test specification, record the results and finally compare

    the results to the appropriate limit in the compliance

    specification. QPHY-HDMI does all of these steps

    for you automatically after indication of the correct

    connection to use.

    Comprehensive and Easy-to-read Test Reports

    Measurement results often need to be summarized and

    tabulated to quickly verify specifications. This information,

    together with instrument and signal acquisition/test

    condition setups, results in a fully documented record.

    QPHY-HDMI streamlines this process by incorporating an

    automatic HTML report generation engine. The created

    test reports contain tabulated numerical values for each

    individual test result, including PASS/FAIL and specifica-

    tion limit columns. Reports can also be saved as PDF,

    HTML or XML.

    Advanced Debug Capability

    If a compliance failure is found, LeCroy’s SDA II serial

    data analysis package is available to help find the root

    cause quickly and easily. SDA II has the ability to perform

    Eye and Jitter measurements simultaneously and is fully

    integrated into the oscilloscope application software.

    In addition, SDA II provides insight into the measured

    Eye and Jitter parameters making is easier to identify

    the sources of problems.

  • 3

    Supported Tests from Version 1.4a of the High

    Definition Multimedia Interface Compliance Test

    Specification

    • 7-2 TMDS — VL

    • 7-4 TMDS — TRise, TFall

    • 7-5 TMDS — Over/Undershoot (Not Mandatory)

    • 7-6 TMDS — Inter-Pair Skew

    • 7-7 TMDS — Intra-Pair Skew

    • 7-8 TMDS — Clock Duty Cycle

    • 7-9 TMDS — Clock Jitter

    • 7-10 TMDA — Data Eye Diagram

    QualiPHY has many predefined configurations that allow

    users to run complete compliance test. In addition, users

    can create their own custom test groups and limit sets.

    When the tests are complete, QualiPHY will generate a

    full test report in PDF, HTML, or XML formats (including

    eye diagrams and other screenshots).

    HMDI Test Results Report.

    QualiPHY has many preset compliance configurations but alsoenables users to create their own configuration and limit sets.

  • QPHY-HDMI-DS-21July11PDF

    TF -HDMI-3.3V adapter provides the necessary 3.3 V pull-uptermination for HDMI testing.

    TF-HDMI-3.3V

    The TF-HDMI-3.3V adapter provides the necessary 3.3 V

    pull-up termination for HDMI testing. The TF-HDMI-3.3V

    provides both a signal path through to the oscilloscope

    with a 3.3 V pull-up termination as well as an input that

    is directly terminated to 3.3 V. This is required for

    terminating the data lines that are not currently under

    test. The TF-HDMI-3.3V-QUADPAK provides four adapters

    and 8 SMA-SMA cables to allow for the testing of all

    HDMI signals (Clock, D0, D1 and D2).

    Product Description Product Code

    QualiPHY Enabled HDMI Software Option *QPHY-HDMIHDMI Pull-up Terminator –- for use TF-HDMI-3.3Vwith the WilderTech HDMI-TPA-P Test Adapter SetHDMI Pull-up Terminator Quad Pack †TF-HDMI-3.3V-QUADPAK– for use with the WilderTech HDMI-TPA-PTest Adapter Set

    * TF-HDMI-3.3V-QUADPAK required.

    † LeCroy recommends using the WilderTech HDMI-TPA-P (plug test adapter) used in conjunction with HDMI-TPA-E (EDID board with EEPROM).

    WaveMaster 8 Zi-A/Zi Series Oscilloscopes4, 6 GHz, 40 GS/s, 4 Ch, 20 Mpts/Ch *‡WaveMaster 804Zi-AWaveMaster with 15.3" WXGA Color Display. 806Zi-A50 Ω and1 MΩ Input6, 13, 16, 20 GHz, 40 GS/s, 4 Ch, 20 Mpts/Ch ‡WaveMaster 808Zi-AWaveMaster with 15.3" WXGA Color Display. 813Zi-A, 816Zi-A, 820Zi-A50 Ω and 1 MΩ Input25, 30 GHz, 80 GS/s, 2 Ch, 40 Mpts/Ch ‡WaveMaster 825Zi-A,WaveMaster with 15.3" WXGA Color Display. 830Zi-A50 Ω and 1 MΩ Input (20 GHz, 40 GS/s, 4 Ch, 20 Mpts/Ch) 45 GHz, 120 GS/s, 1 Ch, 60 Mpts/Ch ‡WaveMaster 845Zi-AWaveMaster with 15.3" WXGA Color Display. 50 Ω and 1 MΩ Input (30 GHz, 80 GS/s, 2 Ch, 40 Mpts/Ch; 20 GHz, 40 GS/s, 4 Ch, 20 Mpts/Ch)

    SDA 8 Zi-A/Zi Series Serial Data Analyzers4, 6 GHz, 40 GS/s, 4 Ch, 32 Mpts/Ch Serial Data Analyzer *SDA 804Zi-Awith 15.3" WXGA Color Display. 50 Ω and 1 MΩ Input 806Zi-A8, 13, 16, 20 GHz, 40 GS/s, 4 Ch, 32 Mpts/Ch SDA 808Zi-A, 813Zi-ASerial Data Analyzer with 15.3" WXGA 816Zi-A, 820Zi-AColor Display. 50 Ω and 1 MΩ Input25, 30 GHz, 80 GS/s, 2 Ch, 64 Mpts/Ch SDA 825Zi-A Serial Data Analyzer with 15.3" WXGA SDA 830Zi-AColor Display. 50 Ω and 1 MΩ Input (20 GHz, 40 GS/s, 4 Ch, 32 Mpts/Ch)45 GHz, 120 GS/s, 1 Ch, 96 Mpts/Ch SDA 845Zi-ASerial Data Analyzer with 15.3" WXGA Color Display. 50 Ω and 1 MΩ Input (30 GHz, 80 GS/s, 2 Ch, 64 Mpts/Ch; 20 GHz, 40 GS/s, 4 Ch, 32 Mpts/Ch)

    DDA 8 Zi-A/Zi Series Oscilloscopes20 GHz, 40 GS/s, 4 Ch, 32 Mpts/Ch DDA with DDA 820Zi-A15.3" WXGA Color Display. 50 Ω and 1 MΩ Input30 GHz, 80 GS/s, 2 Ch, 64 Mpts/Ch DDA with DDA 830Zi-A15.3" WXGA Color Display. 50 Ω and 1 MΩ Input (16 GHz, 40 GS/s, 4 Ch, 20 Mpts/Ch)

    WavePro 7 Zi-A/Zi Series Oscilloscopes4, 6 GHz, 20 GS/s, 4 Ch, 20 Mpts/Ch *‡WavePro 740Zi-A, 760Zi-A(40 GS/s and 40 Mpts/Ch in interleaved mode)with 50 Ω and 1 MΩ Input

    SDA 7 Zi-A/Zi Series Serial Data Analyzers4, 6 GHz, 20 GS/s, 4 Ch, 20 Mpts/Ch *SDA 740Zi-A, 760Zi-A(40 GS/s and 40 Mpts/Ch in interleaved mode)with 50 Ω and 1 MΩ Input

    DDA 7 Zi-A/Zi Series Oscilloscope6 GHz, 20 GS/s, 4 Ch, 20 Mpts/Ch *DDA 760Zi-A(40 GS/s and 40 Mpts/Ch in interleaved mode)with 50 Ω and 1 MΩ Input

    SDA Series Serial Data Analyzers4 Ch; 4 GHz Serial Data Analyzer; 20 GS/s; 20 Mpts/Ch *SDA 40204 Ch; 6 GHz Serial Data Analyzer; 20 GS/s; 20 Mpts/Ch *SDA 60204 Ch; 9 GHz Serial Data Analyzer; 9 GHz, 40 GS/s *†SDA 900040 Mpts/Ch on 2 Ch; 6 GHz, 20 GS/s 20 Mpts/Ch on 4 Ch4 Ch; 11/6 GHz Serial Data Analyzer; 11 GHz, 40 GS/s *†SDA 1100040 Mpts on 2 Ch; 6 GHz, 20 GS/s 20 Mpts on 4 Ch4 Ch; 13/6 GHz Serial Data Analyzer; 13 GHz, 40 GS/s *†SDA 1300040 Mpts on 2 Ch; 6 GHz, 20 GS/s 20 Mpts on 4 Ch4 Ch; 18 GHz Serial Data Analyzer; 18 GHz, 60 GS/s *†SDA 1800060 Mpts on 1 Ch, 6 GHz, 20 GS/s 20 Mpts/Ch on 4 Ch

    * The HDMI test specification requires 8 GHz bandwidth for testing clock rates above148.5 MHz. For testing with clock rates below 148.4 MHz, 4 GHz is required.

    † The HDMI test specification requires to use the oscilloscope in 4 Ch mode.

    ‡ SDA II Serial Data Analysis Option required.

    Customer ServiceLeCroy oscilloscopes and probes are designed, built, and tested to ensure high reliability. In the unlikely event you experience difficulties, our digital oscilloscopesare fully warranted for three years and our probes are warranted for one year.

    This warranty includes: • No charge for return shipping

    • Long-term 7-year support • Upgrade to latest software at no charge

    Ordering Information

    ORDERING INFORMATION

    Local sales offices are located throughout the world.Visit our website to find the most convenient location.

    1-800-5-LeCroy www.lecroy.com

    © 2011 by LeCroy Corporation. All rights reserved. Specifications, prices, availability, and delivery subject to changewithout notice. Product or brand names are trademarks or requested trademarks of their respective holders.