HC2 IMPLANTS AND PROSTHETIC...
Transcript of HC2 IMPLANTS AND PROSTHETIC...
HC2
two part IMPLANT SYSTEM HC2
• Secure anit-rotation through high-precision internal hexagon
• Apical expanded bone thread with No-Itis® surface
• Excellent stability in all bone qualities: double condensation
• Universal application for fixed and removable prosthodontics
• Surface blasted, etched and anodised
• Abutment alignment and 100% tightness by the taper
2
HC2 IMPLANTS AND PROSTHETIC COMPONENTS
1. Ask your laboratory to prepare a drill template with the determined bore-holes for the pilot drills. To be on the safe side, you can ask the laboratory to insert guide sleeves (REF BFH) into the boreholes, which specify the exact drill direction. Please use a 2.0 / 2.2 mm Ø drill for the pilot drilling.
2. For the following drill sequences you can use drill stops, which can be attached and tightened to the drill according to the length of drill-ing channel. Mucous membrane thickness and template height are taken into account as needed. Thanks to the extremely high cutting efficiency of our drills, no ascending drilling sequences will usually be required. Recom-mended RPM: 2000-5000. Apply sufficient cooling and allow the cooling to reach the working blades of the drills.
Contra-angle handpiece 2.0 /mm Ø
Drillstop
Holes with guide sleeve
Template
Muscosa
Jaw bone
(Example)
PRELIMINIARY WORK FOR TEMPLATE APPLICATION
DFN 2.9 13 DFN 2.9 15
DS 2(Pilot drill)
(DFN 3.4 ) / DFN 3.7 DFN 4.2-4.5 (C-Drill 4.2 - 4.5)(Corticalis drill)
DS 2(Pilot drill)
DFN 3.0 (DFN 3.4) (C-Drill 3.7)(Corticalis drill)
1.1 Drill for contra-angle handpieceTypical sequence of the drills:
Step drill
Bone
Bone
Boneor
The use of DHC is done without previous pilot drill. Max. torque during insertion of HC 2.9: 35 Ncm.
DS 2(Pilot drill)
DFN 3.7 DFN 5.5 (C-Drill 5.5)(Corticalis drill)
Bone
DS 2(Pilot drill)
DS 2.8(Pilot drill)
Bone
(hard bone: DFN/DFLN 3.4) Max. torque during insertion of HC 3.3: 40 Ncm.
General note - HC2 implants are used as compression screws. In order to acchieve a good bone condensation and implant stability, the drilling should be carried out thin-ner than the core diameter of the implant. The minimal diameter of the drill depends on the bone density. It is therefore not possible to advise drill-sequences which fit all bone-qualities. Typically in the soft maxillary bone only small drill-diameters are used (e.g. the usage of DOS1 only, for HC2 implants with 3.3 - 5.5 mm diameter), whereas in the highly mineralized lower jaw a specific drill sequence with respect to the mineralisation of the bone is necessary. For insertion under pressure use the handgrip. Due to technical reasons HC2 2.9 mmd is not available with expanded apical thread.
HC2 2.9 (head diameter 3.2 mm)
HC2 3.7
HC2 3.3
HC2 5.5 mm HC2 5.5 mm, 6+2
HC2 4.5 mm HC2 4.5 mm 6+2
3
1. SURGERY
1.2 Implant packaging
1. Open the lid. The implant is connected to the lid with a break joint.2. Remove the implant without touching the inner walls of the tube.
Original packaging Open packaging using the flap Remove the label and stick it intoyour patient’s file.
1.7 Result: a correctly inserted implant
HC2 implant
Jaw
1.4After you have attached the insertion tool, firmly hold the lid in your hand and break the implant off the top along the break joint.
1.3Attach the insertion tool to the implant by hol-ding the top, to which the implant is secured, with your other hand. Alternative: Firmly attach the assembled con-tra-angle handpiece instrument IT 2.5 M to the implant. For ratchets ITL 2.5 can be used as well.
1.5 Using the ratchet screw the implant clockwise into the cavity.
The enossal part of the implant must be com-pletely covered by the bone.
After insertion the implant can be turned by a 1/4 rotation backwards in order to relieve the bone and allow blood access to the implant site.
TW 2
Jaw
1.6 Disengage the insertion tool from the implant.
Jaw
TW2
IT 1 or IT 2Make sure that the
hexagon is in the correct position
HC2 Implant
Break joint Lid with
implant mount
Break joint
Lid
1.8 Close the implant with the suitable cover screw
HT 1.25
CSTI
HC2 implant
Jaw
1.9 After healing period: Remove cover screw
HT 1.25
CSTI
HC2 implant
Jaw
4
Impression tray
Impression post HLT
HC2 implant
Jaw
Hex-instrument HT 1.25
Thightening of the impression post HLT
HC2 implant
Jaw
Arrow: Top view. Direction of rotation: clockwise.
1.10Usage of the handgrip and HC2 adapter
1.11Break off the holder
1.12Insertion of the implant with axial pressure while turning
IT HC
2.1 PICK-UP IMPRESSIONS
2.1.1 Impression taking using the pick up method
Impression taking using an individual impression tray
2.1.2 Prior to the impression
Impression taking with an A-silicone such as Safeprint by Dr. Ihde Dental. The use of open and closed impression tray is possible.
The impression post HLT must not necessarily be unscre-wed from the implant in order to remove the impression tray. It can be repositioned later as well.
1. SURGERY AND PICK-UP IMPRESSIONS
Handgrip
5
2.1.3 Take impression
Disengage HLT from the implant: HLT remains in the im-pression
After the impression is taken, the implant is closed with a healing abutment (Gingiva former - straight or anatomic) and the impression is sent to the laboratory.
2.2.1 Impression taking with a closed impression tray
Impression taking using an individual impression tray
2.2.2 Prior to the impression
Impression taking with an A silicone such as Safeprint® IM by Dr. Ihde Dental.
When applying the closed-tray method, the impression post TS/TSL HC is not located in the impression tray after the impression is removed, but in the implant.
2.2.3 Remove impression
When the closed-tray method is applied, the impression post TS/TSL HC remains on the implant after the impres-sion tray is removed.
After removal of the impression tray the impression post will be unscrewed and repositioned in the impression.
After the impression is taken, the implant is closed with a healing abutment (Gingiva former - straight or anatomic) and the impression is sent to the laboratory.
Loosen screws with HT 1.25
Window in impression tray
HLT
HC2 implant
Jaw
Tighten the impression post manualy with the top screw
TS/TSL HC
HC2 implant
Jaw
Arrow: Top view. Direction of rotation: clockwise.
Impression post TS/TSL HC
HC2 implant
Jaw
TS/TSL HC
HC2 implant
Jaw
2.2 CLOSED TRAY IMPRESSION TAKING
2.2 CLOSED TRAY IMPRESSION TAKING
6
3. PROCEDURES IN THE LABORATORY
3.1 Preparation of the impression tray for the model generation
Pick up method:
Screw analog or M-analog against the impression post.
3.2 Closed-tray method:
Screw analog IA or M-analog IA HC M to the transfer post TS HC. Ⓐ
Subsequently the impression post is repositioned in the impression. Ⓐ
The impression can now be casted. In M analogs (IA HC M) block the lower access to the lock screw out prior to casting.
3.3
The impression is poured. Then the impression posts (HLT or TS/TSL HC) are unscrewed from the laboratory analog.
3.4
The laboratory analog is now in the proper position and orientation in the gipsum.
3.5
Positioning of the screwable abutments TLA15 HC, thereby the optimal position and adequate angulation must be determined.
NOTE The hexagon must be completely inserted into the analog.
Fasten the laboratory analog in the impression
using HT 1.25
HLT
IA or M-analog
Tighten the impression post onto the laboratory analog using the
knurled screw
TS HC
IA or IA HC M
Ⓐ
Ⓐ
Gipsum
HT 1.25
screw eindrehen
TLA 15Achten Sie auf die korrekte
Stellung des Hexagons
IA or IA HC M
Gipsum
IA or IA HC M
Laboratory analog
Pour gipsum in
Arrow: Top view. Direction of rotation: clockwise.
Arrow: Top view. Direction of rotation: counterclockwise.
Arrow: Top view. Direction of rotation: clockwise.
7
The problem:
Implants, which are inserted with directional divergences, cause the technician increased difficulties
Advantages at a glance:
3. PROCEDURES IN THE LABORATORY
TLA 15 HCPattern Resin
Bone
3.6
Ensure proper position of the abutment when transferring into the mouth.
Tightening torque of the screw during fastening on the implant: 20 Ncm
3.7
If more than one angled abutment is used, your laboratory will prepare a detachable synthetic bar (e.g. from Pattern Resin) in order to facilitate the correct positioning in the mouth.
TLA 15 HC
Bone
Access tosafety screw
Gingival region
Retention area
Jacket
Safetyscrew
APPLICATION IA HC M ANALOGUE
Please note:For HC2 implants with internal dual-hex (12 corners, HC2) the implant analogs IA 12 (REF 418177) or IA12 M (REF 418178) are used.
The solution:
IA HC M tapered analog with jacket and TS HC or TSL HC impression post (right)
The lock screw is firmly tightened against the analog using the hexagon wrench HT 1.77. Thereby the jacket is affixed. Now the M analog can be secured in the impres-sion. Depending on the implant type this is done by attaching or tightening of the M analog.
M analogs for HC2: Code: IA HC MPack with 1 analog, 1 lock screw and 5 sleeves (REF 418115)
• each M analog can be removed from the model at any time.• no saw-cut model is necessary any more• the 8 degree cone angle compensates for angulations between the implants• all M analogs are equipped with rotation protection.• damaged analogs can be easily replaced on the same model.• adjustments can be made directly on the analog. The analog can be easily removed
from the model• disturbing analogs can be temporarily removed• these analogs do not need to be “deflasked” from previous models. Leave the jacket,
use the analogs right again• the analogs can be reused. You save money
8
The surface is sandblasted and acid etched (high temperature), the apical thread has a No-Itis® surface. HC2 implants feature an internal 6-edge, an internal marginal taper and a US standard internal thread.
NEW HC2 implant is now available with aggressive apical
thread and No-Itis® surfaceAs a result of many years of clinical observation of products, Dr. Ihde Dental AG has revised the design of the famous HC2 implant: the broadened apical thread is fully self-cutting and carries the yellow No-Itis® surface. Thanks to the new thread portion, the implant is more stable even in weak bone and high insertion torque can be reached.
If the implant is anchored in the 2nd cortical, it may be used in immediate load protocols.
Especially in the upper jaw the usage of the new handgrip (REF311431, with Adapter IT HC REF418196, see page 15) for inserting the implant is advisable. This tool allows to apply vertical insertion forces and will en-hance the anchorage.
The drill sequence remains unchanged compared to the former design of the HC2 implant. And of course all abutments and tools remain the same also if the new implant is applied.
IMPLANTS
Dimensions HC2 4.5 + 13
a) thread Ø basal 4.3 mm b) hight of the wide thread part c) micro thread length 2.5 mm d) nominal Ø 3.7 mm
HEXACONE® IMPLANTS
Description enossal Ø enossal length Code REF Price cat.
HC2 2.9 13 2.9 mm 13 mm HC2 2.9 13 13-413200 G
HC2 2.9 15 2.9 mm 15 mm HC2 2.9 15 13-413201 G
HC2 3.3 8 3.3 mm 8 mm HC2 3.3 8 13-413220 G
HC2 3.3 10 3.3 mm 10 mm HC2 3.3 10 13-413221 G
HC2 3.3 11.5 3.3 mm 11.5 mm HC2 3.3 11.5 13-413222 G
HC2 3.3 13 3.3 mm 13 mm HC2 3.3 13 13-413223 G
HC2 3.3 15 3.3 mm 15 mm HC2 3.3 15 13-413224 G
HC2 3.7 8 3.7 mm 8 mm HC2 3.7 8 13-413202 G
HC2 3.7 10 3.7 mm 10 mm HC2 3.7 10 13-413203 G
HC2 3.7 11.5 3.7 mm 11.5 mm HC2 3.7 11.5 13-413210 G
HC2 3.7 13 3.7 mm 13 mm HC2 3.7 13 13-413204 G
HC2 3.7 15 3.7 mm 15 mm HC2 3.7 15 13-413205 G
HC2 4.5 8 4.5 mm 8 mm HC2 4.5 8 13-413206 G
HC2 4.5 10 4.5 mm 10 mm HC2 4.5 10 13-413207 G
HC2 4.5 11.5 4.5 mm 11.5 mm HC2 4.5 11.5 13-413208 G
HC2 4.5 13 4.5 mm 13 mm HC2 4.5 13 13-413209 G
HC2 5.5 8 5.5 mm 8 mm HC2 5.5 8 13-413211 G
HC2 5.5 10 5.5 mm 10 mm HC2 5.5 10 13-413212 G
HC2 5.5 11.5 5.5 mm 11.5 mm HC2 5.5 11.5 13-413213 G
HC2 5.5 13 5.5 mm 13 mm HC2 5.5 13 13-413214 G
HC2 2.9, 3.3, 4.5 and 5.5 implants will be converted from Dualhex to Hex.HC2 2.9 must only be used in the load reduced area and not as single tooth implant.
c
b
a
d
9
IMPLANTS AND SURGICAL ACCESSORIES
HC2 6+2 was developed specially for the area of the 1st and 2nd molars in the upper and lower jaw. It is possible and recommendable to use it as a com-pression screw implant in the upper jaw. Enossal length 6 mm. The upper edge of the polished 75° reverse cone can end at bone level or slightly above it. The surface is sandblasted and acid etched in a high-temperature process.
Application limitations: HC2 2.9 mm implants may not be placed in a heavily loaded area, especially not in the molar area. Likewise these implants may not be used where diagonal loading occurs, i.e. not for upper anteriors. Under no circumstances may HC2 2.9 mm implants be used for work that involves unsupported occlusal surfaces (consoles). If used in immediate load protocols, the prosthetic construction must be inserted on the 2nd postoperative day, and it should not be removed within the first 6 months.
SURGICAL ACCESSORIES
Each implant is supplied with this surgical screw (CSTI - REF 418101).
HEXACONE® 6+2 IMPLANTS
Description enossal Ø enossal length Code REF Price cat.
HC2 4.5 6+2 4.5 mm 6-8 mm HC2 4.5 6+2 13-413217 G
HC2 5.5 6+2 5.5 mm 6-8 mm HC2 5.5 6+2 13-413218 G
HC2 4.5 6+2 and 5.5 6+2 implants will be converted from Dualhex to Hex.HC2 6+2 can be countersinked in the bone.
75 ° conus
b
a
c
a) enossal Ø: 4.5 - 5.5 mmb) enossal length: 6 - 8 mmc) reverse conus: 2 mm
4.6 mm 4.6 mm
6 mm 6 mm
Description Code REF Price cat.
Gingivaformer
for 3 mm mucous membrane height
HSI 3 13-418111 B
for 5 mm mucous membrane height
HSI 5 13-418112 B
Wide gingivaformer
for 3 mm mucous membrane height
HSIW 3 13-418191 B
for 5 mm mucous membrane height
HSIW 5 13-418192 B
Anatomic gingivaformer
3 mm hight, 4.5 mm widthHSI 3-4.5
13-418268 B
3 mm hight, 5.5 mm widthHSI 3-5.5
13-418269 B
5 mm hight, 6.7 mm width HSI 5-6.7 13-418270 B
Gingivaformer 3 mm hight, 3.3 mm width HSIS 3-3.3 13-418277 B
Gingivaformer MU for HC MU GF MU 13-418302 B
No-Itis® The innovative implant surfaceImplants with the new No-Itis®-surface are double-sandblasted and then etched under heat. As final step an electro-chemical staining will be applied and this last step of the surface preparation smoothens small wells (up to around 5 Micrometers) in the surface. Smooth implants (e.g. systems BCS, BOI) receive the final surface treatment without any prior sandblasting or etching.
This surface, which is new in dental implantology, is extremely clean and keeps bacteria off the the implant. This surface has been proven successful in traumatology for a long time. The reduction of roughness on the surface helps preventing peri-implantitis.
During the insertion of the implants the smoother surface reduces heat and thereby less torques is necessary and less heat develops. All other parameters like the drilling sequence etc. remain unchanged.
10
ABUTMENTS FOR CEMENTED PROSTHETICS
HC SET 1
Screw Description Code REF Price cat.
Screwable abutment without anti-rotation protection for cemented bridges. Trimmable down and abradable is possible. Height above implant 8.5 mm, screw in with HT 1.25 Hex key. The impression is made directly on the TCA, with tool TZ HC.
TCA 13-418129 B
Screwable abutment without anti-rotation protection for cemented bridges. Trimmable down and abradable is possible. Screw in with HT 1.25 Hex key. The impression is made directly on the TCA.
TCA W 13-418173 B
Superstructure with hex and screw, straight, for cemented bridges. Can be shortened and trimmed. Height above implant 8.5 mm. Fasten with HT 1.25.
TLA HC 13-418133 D
Abutment narrow to HC 2.9 Fasten with HT 1.25.
TLAS 13-418134 D
Abutment TLA HC 2 (GH) TLA HC2 13-418170 D
Abutment TLA HC 4 (GH) TLA HC4 13-418171 D
Abutment TLA W TLA W 13-418193 D
TLA, 15º angled, 1 mm gingival height (GH), including screw TLA 15 HC1 13-418135 F
TLA, 15º angled, 2 mm gingival height (GH), including screw TLA 15 HC2 13-418136 F
TLA, 15º angled, 3 mm gingival height (GH), including screw TLA 15 HC3 13-418137 F
TLA, 25ºangled, 1 mm gingival height (GH), including screw TLA 25 HC1 13-418139 F
TLA, 25º angled, 2 mm gingival height (GH), including screw TLA 25 HC2 13-418140 F
TLA, 25º angled, 3 mm gingival height (GH), including screw TLA 25 HC3 13-418141 F
Anatomic Abutment ANAB 13-418276 E
Recommended insertion torque: 20 Ncm
SF 21
SF 21
GH
GH
Impression taking and laboratory accessories
Code/REF TLA HC REF 13-418133 TZ HC REF 13-418179 PA HC REF 13-418181 IA 12 REF 13-418177**
Straight abutment Impression utility Castable cap Implant analogue with 12-edge
REF 13-418182 for the complete SET
Price category for the SET F
Description Code REF Price cat.
Temporary cap, for TCA W HC, TLA W HC TPB W 13-418194 A
TEMPORARY CAP
** Note: For the HC2-implant with 12-edge, the implant analogue IA12 (REF 13-418177) or IA12 M (REF 13-418178) is used.
Impression taking and laboratory accessories
CodeREF
TSL HC
13-418110
TS HC
13-418109
HLT
13-418108
HLTC
13-418107
SF HLT long
13-418185
IA HC / IA 12 HC 2
13-418113/13-418177**
IA HC M / IA 12 M HC 2
13-418115/13-418178**
PA HC
13-418181
PA TLA HC
13-418172
Impression post for HC. Hight: 15.5 mm
Impression post for HC, Hight: 10.6 mm
Impression post for TLA, TLA 15, TLA 25
Transfer post. Sui-table for 6-edge and 12-edge. Click on.
Pickup-screw for 418108/HLT impression post
418113 = Implant analogue for Hex 418177 = for Dual Hex
Implant analoguewith 5 sleeves, intern. Hex
Castable abutment for TCA, TLA
Castable abutment for TLA HC2/4
Price cat. C C C C B B C A A
11
ABUTMENTS FOR SCREW-IN PROSTHETICS
** Note: For the HC2-implant with 12-edge, the implant analogue IA12 (REF 13-418177) or IA12 M (REF 13-418178) is used.
Impression taking and laboratory accessories
CodeREF
TST13-418147 SFL BTT
13-418100PSTR (grey) 13-418124 (pack of 5)
PSTA 13-418123 (pack of 5)
SF13-418151
Transfer post Long screw TCT-analogue
Castable abutment, 12 mm high, round inside
Castable abutment, 12 mm high, edged inside
Fastening screw
Price cat. B A B B B B
In this approach the position of the TCT hex is assigned.
Description Code REF Price cat.
Screwable abutments for bridges and bars, deliverable for mucogingival levels of 3, 4, 5, 6 mm. Screw in with HT 1.77.
TSA 3 13-418143 B
TSA 4 13-418144 B
TSA 5 13-418145 B
TSA 6 13-418146 B
Description Code REF Price cat.
Screwable mesostructure for bridges and bars, screw in with HT 1.77 hex key. For mucogingival levels of 0.5 mm, 1.5 mm and 2.5 mm.
TCT HC 0.5 13-418130 B
TCT HC 1.5 13-418131 B
TCT HC 2.5 13-418132 B
Recommended insertion torque: 20 Ncm
Impression taking and laboratory accessories
CodeREF
TS13-418142
BTS13-418152
PSS (white) SF13-418151
Impression post TSA-analogue Castable abutment, 10.5 mm high 5 per pack
Fastening screw for PSS on BTS/TSA
Price cat. B B B B
Impression taking and laboratory accessories
CodeREF
IA HC / IA 12 HC 2 13-418113 / 13-418177**
HLT 13-418108
PSTR 13-418124 (5 pieces)
Implant analogue for HC2Ⓐ
IA HC = 6 -edges, IA 12 HC = 12-edgesTransfer post for HC and HC 2, with Hex.
Alternative: Castable abutment, round inside 12 mm high
Price cat. B C B
IA HC IA 12 HC
Description Code REF Price cat.
Screw for PSTA SF TCTL 418165 A
Castable abutment,12 mm high, edged inside PSTA 418123 B
Screw-on mesio structure for bridges and bases TCTL 0.5 13-418138 D
TCT Set (TCTL 0.5, PSTA, SF TCTL) 13-418263 F
Hex
TCT-SET
SF TCTL
PSTA
TCTL 0.5
12
ABUTMENTS FOR REMOVABLE PROSTHETICS
CASTABLE ABUTMENTS
Description Code REF Price cat.
Castable abutments with hex, incl. metal basis (Ti6Al4V) and screw for crown 10 mm high, white (not for casting-on)
PLAB 13-418120 B
Castable abutments with hex, incl. metal basis (CoCrMo) and screw for crown 10 mm high, white (for direct casting-on)
PLAB 2 13-418183 G
Castable abutment including screw for bridges (UCLA technique) 10 mm, red
PLA 13-418158 B
Recommended insertion torque: 20 Ncm
** Note: For the HC2-implant with 12-edge, the implant analogue IA12 (REF 13-418177) or IA12 M (REF 13-418178) is used.
ABUTMENTS
Description Material Code REF Price cat.
HEX-reverse-abutment, incl. screw SF 275 (REF 418275)
Ti6Al4V HRA HC 13-418273 D
Tempbase for HRA HC TPB E 13-418274 C
This abutment turns the internal hexagon of the HC2-implant into an external standard-hexagon. The prosthetic screw is screwed through. It tightens the prosthetic and the abutment at the same time.
Ti6Al4V CoCrMo
SF 275
TPB E
HRA HC
Impression taking and laboratory accessories
Code HLT HLTC SF HLT long IA HC / IA 12 HC 2
REF 13-418108 13-418107 13-418185 13-418113 / 13-418177**
Transfer post for HC and HC 2, with Hex.
Transfer post for snap-ping onto the HC2 im-plant. Suitable for 6-edge and 12-edge. Click on.
Pickup-screw for 418108 / HLT impression post
Implant analogue for HC2Ⓐ
IA HC = 6 -edgesIA 12 HC = 12-edges
Preiskat. C C B B
IA HC IA 12 HC
Description Code REF Price cat.
Localicer® for HC2 hight 2 mm LOC HC 2 13-418116 C
Localicer® for HC2 hight 4 mm LOC HC 4 13-418117 C
Adequate tool: HT 1.77. We recommend to use minimally 6 implants per jaw and to use a single denture as splinting.
LOCALICER®
ACCESSORIES FOR LOCALICER®
Description Code REF Price cat.
instrument for mounting and de-mounting Localicer Caps LOC Tool 13-462335 C
Analog + impression cap set AA LOC 13-462337 C
Set with 4 nylon caps + 1 housing NCS 13-462338 D
Set of two, yellow, with increased friction strength R-Cap 13-462336 B
Pull-off force: *black 125 g, red 350 g, blue 500 g, pink 1000 g // *Black cap is for temporary solutions up to one month.
13
ABUTMENTS FOR REMOVABLE PROSTHETICS AND ACCESSORIES
MULTI - UNIT ABUTMENTS
ACCESSORIES FOR MULTI - UNIT ABUTMENTS
Description Code REF Price cat.
Temporary base, Ti6Al4V (SF MU2 has to be ordered separately) TC MU2 13-418290 D
Transfer straight, Ti6Al4V, incl. screw SFL MU2 TS MU2 13-418291 C
Castable for multiunit, incl. screw PA MU2 13-418292 A
Screw for TC MU, Ti6Al4V SF MU2 13-418293 A
Lab analogue for multiunit, Ti6Al4V IA MU2 13-418295 B
Hex-instrument, long HT 1.25 13-425100 C
Hex-instrument, long HT 1.77 13-425103 C
Screw
Description Code REF Price cat.
MU2 17 HC, angled, Ti6Al4V, incl. SF 20 MU2 17 HC 13-418281 L
MU2 35 HC, angled, Ti6Al4V, incl. SF 20 MU2 35 HC 13-418282 L
MU2S 0.5 HC, straight, Ti6Al4V MU2S 0.5 HC 13-418283 G
MU2S 1.5 HC, straight, Ti6Al4V MU2S 1.5 HC 13-418284 G
MU2S 2.5 HC, straight, Ti6Al4V MU2S 2.5 HC 13-418285 G
GF MU2 gingivaformer, Ti6Al4V. Incl. SF MU2 H above abutment shoulder 6 mm 13-418286 C
MU2 localicer, Ti6Al4V. Incl. SF MU2 Hight above abutment shoulder 6.7 mm 13-418287 C
Prosthetic screw for MU2 SF 20 13-420943 A
Insertion of the angled MU2-abutments with HT 1.25 // Insertion of the straight MU2S-abutments with HT 1.77
h = 3 mm
h = 4 mm
6 mm
6.7 mm
Description Code REF Price cat.
Ball abutments for fitting prostheses, head diameter 2.5 mm, for fit-ting to TSA 3 - 6 abutments, application on TSA 3 - 6 abutments
SB 13-418153 B
ACCESSORIES
Impression taking and laboratory accessories
Pull-
off f
orce
s
Nylon cap NC Nylon cap R-NC
with increased friction strength (for usage with worn-out Localicer)
for poly-merization
directly into the denture
Code TSA 3 to 6 TS BTS NC NC 1 NC 2 R-NC R-NC 1 R-NC 2 H
REF 13-418143 / -46 13-418142 13-418152 13-465028 13-465029 13-465030 13-465034 13-465033 13-465032 13-465031
Hight above implant 3-6 mm
Impression post for TSA and TCA
TSA- analogue
ca. 1200 g white
ca. 800 g pink
ca. 500 g yellow
green, strong pink, medium
orange, soft
Metal sleeve for all NC
Price cat. B B B A A A A A A B
Description Hight h Code REF Price cat.
Ball abutment, head - 0 2.5mm
Use with HT 1.25
Use with NC-caps
0.5 mm TB 0.5 13-418126 B
2.0 mm TB 2 13-418127 B
4.0 mm TB 4 13-418128 B
hhh
Description Code REF Price cat.
Bur cylinder, rverse, 20°. Incl. screw SF 20 FZ 20 HC 13-418262 D
REVERSE CONE CYLINDER
14
INSTRUMENTS AND TOOLS
Description Type Code REF Price cat.
IT 2.5 Short, 8 mm, click-on, 6-edges IT 2.5 13-418174 B
ITL 2.5 Long, 22 mm, click-on, 6-edges ITL 2.5 13-418175 B
ITM 2.5 Medium, 20 mm, click-on, 6-edges ITM 2.5 13-418176 B
IT 2.5 M Insertion tool for contra-angle handp. IT 2.5 M 13-418150 B
IT 2.5 M 12Insertion tool contra-angle, 12-edgesInsertion torque with max. 40 Ncm
IT 2.5 M 12 13-418200 B
ITWH 2.5 M Insertion tool contra-angle for HC ITWH 2.5 M 13-418184 C
IT1 12 Insertion tool short,12-edges IT1 12 13-418197 B
IT2 12 Insertion tool long, 12-edges IT2 12 13-418198 B
IT3 12 Insertion tool medium,12-edges IT3 12 13-418199 B
INSERTION TOOLS
Ø working rangeMax. working depth
Total length
Color Code REF Price cat.
0.1 mm - 1.5 mm 15 mm 31.7 mm yellow BCD 1 13-900240 C
0.1 mm - 1.5 mm 15 mm 42 mm yellow BCDX 1 13-900243 C
2.0 mm / 3.6 mm 13 mm 30 mm DFN 2.9 13 13-418102 E
2.0 mm / 3.6 mm 15 mm 32 mm DFN 2.9 15 13-418103 E
2.0 mm 17 mm 36.5 mm DS 2 13-425001 D
2.8 mm 17 mm 36.5 mm DS 2.8 13-425005 D
2.7 mm 18 mm 36 mm DFN 3.0 13-425030 E
3.0 mm 18 mm 36 mm DFN 3.4 13-425031 E
3.4 mm 18 mm 36 mm DFN 3.7 13-425032 E
4.05 mm 18 mm 36 mm DFN 4.2 - 4.5 13-425033 E
4.4 mm 18 mm 36 mm DFN 5.5 13-425034 E
2.7 mm 18 mm 39 mm DFLN 3.0 13-425035 E
3.0 mm 18 mm 39 mm DFLN 3.4 13-425036 E
3.4 mm 18 mm 39 mm DFLN 3.7 13-425037 E
4.05 mm 18 mm 39 mm DFLN 4.2 - 4.5 13-425038 E
3.4 mm 11.5 mm 30 mm DFSN 3.7 13-425039 D
3.9 mm 11.5 mm 30 mm DFSN 4.2 - 4.5 13-425040 D
max. 3.4 mm 5 mm 27 mm C Drill 3.7 13-425043 D
max. 4.05 mm 5 mm 27 mm C Drill 4.2 - 4.5 13-425044 D
max. 5.8 mm 5 mm 27 mm C Drill 5.5 13-425045 D
It has been scientifically proven that HEATLESS® drills generate 55% less heat than traditional bone drills from other manufacturers. This makes it possible to use higher rotational speeds: between 3,000 and 5,000 rpm are recommended with good external cooling and intermittent drill technique.
Namely for the implant system HC2
HEATLESS® - DRILL DFN / DFLN FOR IMPLANTS WITH CONICAL CORE
TITAN BASE
Description Type Material Code REF Price cat.
Titan baseincl. screw
Abutment basefor zirkonium Ti6Al4V MB HC 13-418267 D
Titan baseincl. screw
Ti6Al4V MBR HC 13-418272 D
Base for TPB 3 HCincl. screw SF 20
For scanner to HC implants BioPEEK® TPB 3 HC 13-418280 B
15
TOOLS
TOOLS
Description Type Length Code REF Price cat.
Hex-Tool 1.25 long 21 mm HT 1.25 13-425100 C
Torx-Tool 1.25 long 21 mm TT 1.25 13-425105 C
Hex-Tool for contra-angle, extra-long 45 mm HTW 1.25 13-425111 B
Hex-Tool 1.25 kurz 14 mm HTS 1.25 13-425101 C
Hex-Tool 1.77 for all suprastructures 19 mm HT 1.77 13-425103 C
Hex-Tool 1.25 M for contra-angle, long 26.1 mm HT 1.25 M 13-425112 B
Hex-Tool 1.77 M for contra-angle, long 28.6 mm HT 1.77 M 13-425113 B
Hex-Tool, extra-long 45 mm HTX 1.25 13-425102 C
Hex-Tool for contra-angle, extra-long 45 mm HTX 1.77 13-425104 C
Punch, 4.9 mm 0 for contra-angle PUW 1 13-425404 C
Punch, 3.9 mm 0 for contra-angle PUW 2 13-425405 C
Punch, 5.2 mm 0 manual PU 13-425406 C
standardized probe
Scale 1 mm for X-ray measurements
22 mm PDG 13-425400 A
DX2Drill extension contra angle handpiece, extends by 19 mm
DX2 13-500704 D
DX2 HDrill extention contra angle handpiece, extends by 19 mm, W&H-hexagon on shank and in front section
DX2 H 13-500708 D
Guide sleeveTitanium, for pilot drill,5 pieces / unit
10 mm BFH 13-425401 A
X-ray measuring sphere
Surgical steel5 pieces / unit, 0.5 mm 0
RM 13-425403 A
Adapter for handgrip Adapter IT HC 13-418196 C
Handgrip, self-locking ** 13-311431 V
Handgrip for adapter, screwable 13-311430 V
Adapter for all contra angle handpiece instruments, compatible to handle
110 mm 13-310530 C
Ratchet For all Hex-instruments and applicators RAT 2 13-425051 K
RatchetAngled, for all Hex-instruments and applicators
RAT 3 13-425052 S
TW 2 * Torque Wrench (heavy duty), 10 - 70 Ncm TW 2 13-425402 S
UAW***Universal ratchet adapter for all contra angle handpiece instruments, for TW2 and RAT2. Max. 30 Ncm
UAW 13-425107 E
* It is recommended to have the torque ratchets recalibrated by us once a year.** for cleaning this instrument an ultrasonic cleaning device and a thermo-desinfector (i.e. Miele TD-series) are required. If these devices are not available in the dental office the handle with REF311430 should be purchased instead. *** Do not use UAW in combination with RAT2 with Heatless® bone drills. The maximum insertion torque for UAW and Heatless® bone drills is 35 Ncm. UAW may therefore be used only with TW2.
TOOLS
HANDGRIP-TRAY (empty) REF 13-60043 EUR 69,90
Size of closed tray: B = 90 mm / L = 195 mm / H = 45 mm
For safe storage and sterilisation of handgrips (max. 3 pieces) and adapters (max. 8 pieces). Plastic, autoclavable up to 134°C, not sui-table for dry heat sterilizers.
HC20029
REF 13-0002-09_HC2_EN_V002_05/15
Simpladent GmbH Phone +41 (0)55 293 23 70 Dorfplatz 11 [email protected] - 8737 Gommiswald / SG www.simpladent-implants.com
PLEASE CHECK THE VALID PRICE LIST OF YOUR LOCAL COORDINATOR
Symbols on the packs
Production No.
Sterilized by gamma radiation
Sterilization Ethylene oxide
Single-use
product
Instruction for use
Expiry date Store in a dry place
Temperature range from
-5 °C to 35 °C
Store tightly keep closed
Do not use if packing is damaged
Do not resterilize
Manu-facturer
-5 °C
35 °C
Rx ONLYNon-sterile
Intended for use by dentists or surgeons
only
Production date
We are certified DIN EN ISO 13485, and annex II of EEC Directive 93/42 EWG (2007). Due to technical reasons the product dimensions shown in this brochure might deviate from reality. HC2 is a registered trademark. HC2 implants are patent-protected. In case that implants would be reprocessed (cleaned, resterilized) infections could occur, because no validated procedures for reprocessing are available.
HC2 STARTER - TRAY
Autoclavable up to 134 °C, not suitable for dry heat sterilizers This surgical kit contains all drills and tools for first works with the HC2 system. Material: autoclavable plastic
Description Code REF Price €
Insertion tool IT 2.5 13-418174
Insertion tool ITL 2.5 13-418175
Insertion tool for contra angle handpiece
IT 2.5M 13-418150
Hex-instrument, long HT 1.25 13-425100
Spiraldrill DS 2 13-425001
Formdrill DFN 3.0 13-425030
Formdrill DFN 3.4 13-425031
Formdrill DFN 3.7 13-425032
Formdrill DFN 4.2 - 4.5 13-425033
Corticalis drill 3.7 C Drill 3.7 13-425043
Torque wrench TW2 13-425402
Starter-Tray for HC2 (with content)* 13-S60021-K 678,80
* tray without content upon request