Note: The test data was only valid for the test sample(s). This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. Some of the tests or test methods in this report may not in NVLAP accreditation scope and was noted. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. IES LM-79-08 MEASUREMENT AND TEST REPORT Test Model: HBRE100-4000 Report Type: Electrical and Photometric tests including: Luminous Flux, Power Factor, Chromaticity, Luminous Intensity Distribution, THD Test Engineer: Bill Xiong Hill Liu Report Number: R2DG170711050-10 Test Date: 2017-07-13 to 2017-07-14 Report Date: 2017-07-17 Reviewed By: Daniel Duan /EE Manager Test Facility: Test facility was located at No.69, Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China. Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road, Futian Free Trade Zone, Shenzhen, Guangdong, China. Tel: +86-755-33320018 Fax: +86-755-33320008 Accreditation: The NVLAP Lab Code is 200707-0.

Transcript of HBRE 100W 4000K - integratech.be data/industrie/HBRE... · It may not be duplicated or used in part...

Note: The test data was only valid for the test sample(s). This test report is prepared for the customer shown above and for the

device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance

Laboratories Corp. (Shenzhen). This report must not be used by the customer to claim product certification, approval, or

endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. Some of the tests or test methods in this report

may not in NVLAP accreditation scope and was noted.

This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above

version 7.0.

IES LM-79-08 MEASUREMENT AND TEST REPORT

Test Model: HBRE100-4000

Report Type: Electrical and Photometric tests including: Luminous Flux,

Power Factor, Chromaticity, Luminous Intensity

Distribution, THD

Test Engineer: Bill Xiong Hill Liu

Report Number: R2DG170711050-10

Test Date: 2017-07-13 to 2017-07-14

Report Date: 2017-07-17

Reviewed By: Daniel Duan /EE Manager

Test Facility: Test facility was located at No.69, Pulongcun, Puxinhu Industry

Area, Tangxia, Dongguan, Guangdong, China.

Prepared By:

Bay Area Compliance Laboratories Corp. (Shenzhen)

6/F., West Wing, Third Phase of Wanli Industrial Building,

Shihua Road, Futian Free Trade Zone,

Shenzhen, Guangdong, China.

Tel: +86-755-33320018

Fax: +86-755-33320008

Accreditation: The NVLAP Lab Code is 200707-0.

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China.

The NVLAP Lab Code is 200707-0

Page 2 of 15

1. Product Description

General Information:

One sample was received on 2017-07-11.

Model Tested:

Manufacturer:

Product Designation:

Burning Time Before Test:

Driver Model:

Rated Values:

Rated Voltage/Frequency:

Rated Power:

Nominal CCT:

Nominal Lumen Output:

HBREL100-4000

INTEGRATECH

LED High Bay Light

0hour(For New Products)

ELG-100-48A

100-240 V AC 50/60Hz

100 W

4000K

14106Im

2. Standards Used

IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products

ANSI C82.77-2002: Harmonic Emission Limits – Related Power Quality Requirements for Lighting

IES TM-30-15: IES Method for Evaluating Light Source Color Rendition (This method is not in NVLAP

accreditation scope)

3. Description of Test Equipment

Device Manufacture Model No Serial No Test Range Calibration

date

Calibration due

date

1.5m temperature

integrating sphere SENSING SPR-600 S09008 25~50°C 2017-03-09 2018-03-09

High-precision

rapid spectral

analysis system

EVERFINE HAAS-2000 M112048CA136

1125 380-780nm 2017-07-07 2018-07-07

Digital power

meter YOKOGAWA WT310 13398 N/A 2016-12-05 2017-12-05

Programmable

Precision DC

Power Supply

ITECH IT6154 0061 0417 6471

0010 19 0~32V 2017-03-03 2018-03-03

thermometer SENSING NA NA 25、50°C 2017-03-09 2018-03-09

Standard Light

Source SENSING NA LSD090808 N/A 2016-12-05 2017-12-05

Precision

frequency power

supply

ALL Power APW-105N 970613 220V±10%

50Hz 2017-03-03 2018-03-03

AC POWER

SUPPLY EVERFINE VPS1030 PWM 1012017

0-150V, 0-

300V2017-03-03 2018-03-03

Digital CC&CV

DC Power Supply EVERFINE WY12010 1009009 30V/5A 2017-03-03 2018-03-03

Digital power

meter YOKOGAWA WT-210 91KB35700

15/30/60/150/30

0/600 V 2017-03-03 2018-03-03

full-field speed

goniophotometer EVERFINE GO-R5000

YG108492N101

20001

1600mm,3000

W/10A 2017-03-09 2018-03-09

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China.

The NVLAP Lab Code is 200707-0

Page 3 of 15

Device Manufacture Model No Serial No Test Range Calibration

date

Calibration due

date

Wireless Remote

Sensor N/A 433MHz N/A

0°C~50°C;-

20°C~60°C 2017-03-20 2018-03-20

Standard Light

Source EVERFINE D908 1012003 N/A 2016-12-17 2017-12-17

Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been performed using suitable standards traceable to National Primary Standards and International System of Units (SI).

4. Test Method

Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of thesample was maintained at 25°C±1°C during measurement. And relative humidity is less than 65%.

Integrating Sphere System

The system includes AC power source, digital power meter, DC power supply, Spectroradiometer, and integrating sphere. The integrating sphere system is calibrated by standard spectrum light source before measurement.

4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report.

The uncertainty of the light output (luminous flux) measurements is U=2.1% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=32K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=2.1 (K=2) , at the 95% confidence level.

The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level.

Goniophotometer System

The goniophotometer system is calibrated by standard light source before measurement.

Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial uniformity. The product was operated in its intended orientation in application and was recorded in this report. The vertical angle (γ) test intervals were set no more than 1 degree while data for 5 degree intervals is reported. The horizontal angle (C plane) test intervals were set no more than 22.5 degree.

The uncertainty of the luminous intensity is U=1.6% (K=2) , at the 95% confidence level.

Additional Test

The Additional Test item may not be covered by IESNA LM-79-2008. Additional test is THD, was measured by Digital Power Meter after stabilized at 25°C±1°C.Test voltage for THD test would be equal to rated voltage or, in case of a voltage range, maximum value of that range.

The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level.

Fidelity Index and Gamut Index Calculation

The Rf, Rg was calculated according to IES TM-30-15 by using calculation tools. The calculation was based on the

measured SPD from 380nm to 780nm with 1nm intervals. All the colors in this report is for reference only.

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China.

The NVLAP Lab Code is 200707-0

Page 4 of 15

5. Test Result

[Integrating Sphere System]

Total operating time for integrating sphere test: 1.0 hour

Test orientation: Downward

Photometric and Electrical Measurement Result

Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor Luminous Flux(lm)

Efficacy (lm/W)

230.0 50 0.4136 93.51 0.983 14106 150.86

Radiant Flux (W) CCT (K) Duv x y u' v'

42.78 4166 0.0000316 0.3734 0.3723 0.2222 0.4986

Color Rendering Index

Ra

82.0

R1 R2 R3 R4

80 88 93 81

R5 R6 R7 R8

80 82 86 65

R9 R10 R11 R12

6 70 80 58

R13 R14 R15

82 96 75

-20 0 20 40 60 80 100

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China.

The NVLAP Lab Code is 200707-0

Page 5 of 15

Fidelity Index and Gamut Index

Fidelity Index Rf 81

Gamut Index Rg 96

Spectral Power Distribution Comparison

Plot of Rg versus Rf

0

0.2

0.4

0.6

0.8

1

1.2

1.4

1.6

1.8

380 430 480 530 580 630 680 730 780

SPD

(n

orm

aliz

ed

to

Y=1

00

)

l (nm)

Test source Reference source

60

70

80

90

100

110

120

130

140

50 60 70 80 90 100

Rg

Rf

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China.

The NVLAP Lab Code is 200707-0

Page 6 of 15

Chroma Shift by Hue Rf by Hue

Color Vector Graphic

-20%

-15%

-10%

-5%

0%

5%

10%

15%

20%

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Hue Bin

50

55

60

65

70

75

80

85

90

95

100

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Hue Bin

Refenerce Illuminat Test Source

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China.

The NVLAP Lab Code is 200707-0

Page 7 of 15

Color Fidelity by CES Sample

0 20 40 60 80 100

CES01

CES03

CES05

CES07

CES09

CES11

CES13

CES15

CES17

CES19

CES21

CES23

CES25

CES27

CES29

CES31

CES33

CES35

CES37

CES39

CES41

CES43

CES45

CES47

CES49

CES51

CES53

CES55

CES57

CES59

CES61

CES63

CES65

CES67

CES69

CES71

CES73

CES75

CES77

CES79

CES81

CES83

CES85

CES87

CES89

CES91

CES93

CES95

CES97

CES99

Fidelity Index, Rf

Co

lor

Eval

uat

ion

Sam

ple

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China.

The NVLAP Lab Code is 200707-0

Page 8 of 15

Relative Spectral Power Distribution

nm mW nm mW nm mW nm mW nm mW

380 3.361E+00 421 1.495E+01 462 1.485E+02 503 1.207E+02 544 1.940E+02

381 3.042E+00 422 1.660E+01 463 1.433E+02 504 1.243E+02 545 1.950E+02

382 2.764E+00 423 1.849E+01 464 1.378E+02 505 1.278E+02 546 1.958E+02

383 2.533E+00 424 2.046E+01 465 1.319E+02 506 1.308E+02 547 1.970E+02

384 2.399E+00 425 2.294E+01 466 1.262E+02 507 1.341E+02 548 1.980E+02

385 2.290E+00 426 2.572E+01 467 1.192E+02 508 1.372E+02 549 1.992E+02

386 2.064E+00 427 2.868E+01 468 1.123E+02 509 1.400E+02 550 2.001E+02

387 2.243E+00 428 3.241E+01 469 1.050E+02 510 1.429E+02 551 2.011E+02

388 2.327E+00 429 3.624E+01 470 9.739E+01 511 1.463E+02 552 2.021E+02

389 2.078E+00 430 4.056E+01 471 9.084E+01 512 1.484E+02 553 2.034E+02

390 1.935E+00 431 4.520E+01 472 8.458E+01 513 1.509E+02 554 2.049E+02

391 1.880E+00 432 5.032E+01 473 7.893E+01 514 1.538E+02 555 2.059E+02

392 1.786E+00 433 5.655E+01 474 7.455E+01 515 1.561E+02 556 2.072E+02

393 1.746E+00 434 6.307E+01 475 7.138E+01 516 1.583E+02 557 2.082E+02

394 1.705E+00 435 7.046E+01 476 6.918E+01 517 1.601E+02 558 2.096E+02

395 1.822E+00 436 7.906E+01 477 6.768E+01 518 1.624E+02 559 2.107E+02

396 1.915E+00 437 8.886E+01 478 6.644E+01 519 1.640E+02 560 2.117E+02

397 1.857E+00 438 9.996E+01 479 6.626E+01 520 1.659E+02 561 2.130E+02

398 1.942E+00 439 1.121E+02 480 6.628E+01 521 1.676E+02 562 2.146E+02

399 1.976E+00 440 1.269E+02 481 6.651E+01 522 1.692E+02 563 2.159E+02

400 2.061E+00 441 1.431E+02 482 6.680E+01 523 1.707E+02 564 2.168E+02

401 2.146E+00 442 1.626E+02 483 6.731E+01 524 1.724E+02 565 2.183E+02

402 2.226E+00 443 1.836E+02 484 6.797E+01 525 1.735E+02 566 2.191E+02

403 2.364E+00 444 2.066E+02 485 6.890E+01 526 1.752E+02 567 2.207E+02

404 2.554E+00 445 2.305E+02 486 6.965E+01 527 1.761E+02 568 2.220E+02

405 2.742E+00 446 2.551E+02 487 7.115E+01 528 1.774E+02 569 2.228E+02

406 3.016E+00 447 2.775E+02 488 7.242E+01 529 1.790E+02 570 2.241E+02

407 3.129E+00 448 2.973E+02 489 7.429E+01 530 1.795E+02 571 2.254E+02

408 3.564E+00 449 3.112E+02 490 7.676E+01 531 1.802E+02 572 2.262E+02

409 3.883E+00 450 3.184E+02 491 7.910E+01 532 1.818E+02 573 2.273E+02

410 4.364E+00 451 3.161E+02 492 8.194E+01 533 1.831E+02 574 2.285E+02

411 4.778E+00 452 3.067E+02 493 8.507E+01 534 1.840E+02 575 2.296E+02

412 5.318E+00 453 2.917E+02 494 8.826E+01 535 1.849E+02 576 2.308E+02

413 5.934E+00 454 2.719E+02 495 9.178E+01 536 1.861E+02 577 2.317E+02

414 6.668E+00 455 2.490E+02 496 9.532E+01 537 1.869E+02 578 2.323E+02

415 7.508E+00 456 2.264E+02 497 9.884E+01 538 1.878E+02 579 2.339E+02

416 8.506E+00 457 2.062E+02 498 1.027E+02 539 1.891E+02 580 2.346E+02

417 9.478E+00 458 1.888E+02 499 1.064E+02 540 1.895E+02 581 2.353E+02

418 1.071E+01 459 1.749E+02 500 1.100E+02 541 1.910E+02 582 2.359E+02

419 1.200E+01 460 1.630E+02 501 1.138E+02 542 1.919E+02 583 2.370E+02

420 1.336E+01 461 1.551E+02 502 1.174E+02 543 1.931E+02 584 2.373E+02

0.0

0.2

0.4

0.6

0.8

1.0

380 430 480 530 580 630 680 730 780

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China.

The NVLAP Lab Code is 200707-0

Page 9 of 15

nm mW nm mW nm mW nm mW nm mW

585 2.378E+02 626 1.885E+02 667 7.743E+01 708 2.301E+01 749 6.446E+00

586 2.386E+02 627 1.858E+02 668 7.532E+01 709 2.221E+01 750 6.351E+00

587 2.389E+02 628 1.830E+02 669 7.327E+01 710 2.147E+01 751 6.054E+00

588 2.392E+02 629 1.804E+02 670 7.129E+01 711 2.093E+01 752 5.975E+00

589 2.398E+02 630 1.773E+02 671 6.913E+01 712 2.038E+01 753 5.724E+00

590 2.398E+02 631 1.745E+02 672 6.735E+01 713 1.965E+01 754 5.613E+00

591 2.401E+02 632 1.713E+02 673 6.572E+01 714 1.899E+01 755 5.327E+00

592 2.404E+02 633 1.681E+02 674 6.388E+01 715 1.843E+01 756 5.328E+00

593 2.399E+02 634 1.657E+02 675 6.194E+01 716 1.790E+01 757 5.130E+00

594 2.398E+02 635 1.626E+02 676 6.060E+01 717 1.738E+01 758 4.979E+00

595 2.395E+02 636 1.598E+02 677 5.864E+01 718 1.689E+01 759 4.819E+00

596 2.398E+02 637 1.567E+02 678 5.691E+01 719 1.625E+01 760 4.669E+00

597 2.391E+02 638 1.539E+02 679 5.532E+01 720 1.585E+01 761 4.601E+00

598 2.386E+02 639 1.507E+02 680 5.365E+01 721 1.541E+01 762 4.467E+00

599 2.379E+02 640 1.480E+02 681 5.236E+01 722 1.484E+01 763 4.340E+00

600 2.371E+02 641 1.449E+02 682 5.065E+01 723 1.435E+01 764 4.250E+00

601 2.367E+02 642 1.420E+02 683 4.922E+01 724 1.395E+01 765 4.166E+00

602 2.356E+02 643 1.389E+02 684 4.781E+01 725 1.361E+01 766 3.966E+00

603 2.346E+02 644 1.362E+02 685 4.638E+01 726 1.316E+01 767 3.978E+00

604 2.335E+02 645 1.333E+02 686 4.506E+01 727 1.272E+01 768 3.756E+00

605 2.325E+02 646 1.302E+02 687 4.378E+01 728 1.224E+01 769 3.609E+00

606 2.313E+02 647 1.274E+02 688 4.244E+01 729 1.199E+01 770 3.572E+00

607 2.300E+02 648 1.246E+02 689 4.114E+01 730 1.156E+01 771 3.358E+00

608 2.283E+02 649 1.219E+02 690 3.976E+01 731 1.131E+01 772 3.371E+00

609 2.267E+02 650 1.191E+02 691 3.877E+01 732 1.085E+01 773 3.186E+00

610 2.250E+02 651 1.164E+02 692 3.757E+01 733 1.064E+01 774 3.087E+00

611 2.239E+02 652 1.135E+02 693 3.640E+01 734 1.026E+01 775 3.070E+00

612 2.216E+02 653 1.109E+02 694 3.528E+01 735 9.887E+00 776 3.096E+00

613 2.196E+02 654 1.082E+02 695 3.424E+01 736 9.692E+00 777 2.924E+00

614 2.176E+02 655 1.056E+02 696 3.331E+01 737 9.284E+00 778 2.828E+00

615 2.156E+02 656 1.033E+02 697 3.222E+01 738 8.983E+00 779 2.833E+00

616 2.136E+02 657 1.007E+02 698 3.128E+01 739 8.800E+00 780 2.838E+00

617 2.115E+02 658 9.796E+01 699 3.041E+01 740 8.438E+00

618 2.085E+02 659 9.573E+01 700 2.950E+01 741 8.268E+00

619 2.065E+02 660 9.300E+01 701 2.864E+01 742 7.963E+00

620 2.044E+02 661 9.056E+01 702 2.773E+01 743 7.832E+00

621 2.020E+02 662 8.846E+01 703 2.679E+01 744 7.539E+00

622 1.993E+02 663 8.634E+01 704 2.589E+01 745 7.310E+00

623 1.964E+02 664 8.396E+01 705 2.519E+01 746 7.127E+00

624 1.940E+02 665 8.183E+01 706 2.442E+01 747 6.922E+00

625 1.912E+02 666 7.968E+01 707 2.367E+01 748 6.729E+00

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China.

The NVLAP Lab Code is 200707-0

Page 10 of 15

CIE 1931 x y Chromaticity Diagram

7-Step Chromaticity Quadrangles

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

0.30

0.35

0.40

0.45

0.30 0.35 0.40 0.45 0.50 0.55

sample

7-STEP 2200K

7-STEP 2500K

7-STEP 2700K

7-STEP 3000K

7-STEP 3500K

7-STEP 4000K

7-STEP 4500K

7-STEP 5000K

7-STEP 5700K

7-STEP 6500K

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China.

The NVLAP Lab Code is 200707-0

Page 11 of 15

[Goniophotometer System]

Total operating time for luminous intensity distribution: 1.0 hour

Test orientation: Downward

Electrical Measurement

Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor

230.1 50 0.4122 93.2 0.9828

Photometric Measurement

Luminous Flux (lm) Efficacy (lm/W) Imax (cd) S/MH (C0/180) S/MH (C90/270)

14133.2 151.64 5264.0 1.28 1.27

Luminous Intensity Distribution

C0/180 C45/225 C90/270 C135/315 AVG.

Beam Angle (50% Imax): 113.6 113.9 114.5 113.9 114.0

Field Angle (10% Imax): 147.7 147.5 147.5 147.9 147.7

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China.

The NVLAP Lab Code is 200707-0

Page 12 of 15

Luminous Intensity (cd) Distribution Data

C 0° 22.5° 45° 67.5° 90° 112.5° 135° 157.5°

γ

0.0° 5263 5263 5263 5263 5263 5263 5263 5263

5.0° 5243 5246 5257 5260 5259 5258 5256 5251

10.0° 5193 5208 5214 5219 5222 5222 5227 5222

15.0° 5101 5121 5132 5148 5150 5157 5158 5148

20.0° 4950 4968 4986 4991 4995 5017 5028 5011

25.0° 4735 4732 4741 4753 4770 4787 4804 4803

30.0° 4443 4434 4444 4446 4450 4492 4523 4535

35.0° 4100 4103 4102 4081 4072 4123 4183 4201

40.0° 3779 3782 3776 3750 3739 3767 3826 3862

45.0° 3488 3496 3498 3505 3508 3506 3531 3561

50.0° 3153 3159 3172 3196 3212 3210 3223 3243

55.0° 2720 2721 2742 2777 2818 2819 2829 2845

60.0° 2171 2153 2169 2184 2236 2260 2286 2310

65.0° 1565 1555 1560 1574 1612 1665 1709 1731

70.0° 882 866 871 910 948 986 1015 1035

75.0° 329 327 331 347 367 408 432 448

80.0° 43 40 43 50 58 51 62 67

85.0° 5 4 4 5 5 6 6 7

90.0° 1 1 1 1 1 1 1 1

95.0° 1 1 1 1 1 1 1 1

100.0° 1 1 1 1 1 1 1 1

105.0° 1 1 1 1 1 1 1 1

110.0° 2 2 2 2 2 2 1 1

115.0° 2 2 2 2 2 2 2 2

120.0° 2 2 2 2 2 2 2 2

125.0° 2 2 2 2 2 2 2 2

130.0° 2 2 2 2 2 2 2 2

135.0° 3 3 3 3 3 3 3 3

140.0° 4 4 4 4 4 4 4 4

145.0° 4 5 5 5 5 5 5 4

150.0° 5 6 6 6 6 6 6 5

155.0° 6 6 6 6 7 7 7 6

160.0° 7 7 7 7 7 7 7 7

165.0° 7 7 7 7 7 7 7 7

170.0° 6 6 6 6 6 6 7 7

175.0° 6 6 6 6 6 6 6 6

180.0° 6 5 5 5 5 5 6 6

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China.

The NVLAP Lab Code is 200707-0

Page 13 of 15

Luminous Intensity (cd) Distribution Data (cont.)

C 180° 202.5° 225° 247.5° 270° 292.5° 315° 337.5°

γ

0.0° 5263 5263 5263 5263 5263 5263 5263 5263

5.0° 5252 5255 5261 5263 5260 5259 5255 5249

10.0° 5214 5233 5238 5242 5233 5231 5220 5216

15.0° 5137 5165 5188 5190 5183 5179 5159 5138

20.0° 5005 5039 5059 5060 5044 5050 5029 4998

25.0° 4814 4834 4849 4840 4822 4817 4807 4774

30.0° 4555 4572 4573 4554 4529 4517 4506 4484

35.0° 4231 4243 4237 4191 4156 4162 4166 4148

40.0° 3896 3912 3898 3842 3800 3803 3819 3809

45.0° 3601 3617 3618 3595 3575 3543 3527 3520

50.0° 3285 3310 3317 3313 3300 3255 3220 3191

55.0° 2900 2920 2927 2942 2931 2872 2816 2776

60.0° 2366 2367 2359 2356 2340 2293 2258 2227

65.0° 1787 1779 1768 1748 1708 1691 1664 1630

70.0° 1101 1092 1068 1057 1028 1012 986 955

75.0° 484 479 471 449 420 418 404 377

80.0° 90 89 84 71 65 56 48 46

85.0° 8 8 7 7 7 6 6 6

90.0° 0 0 0 0 0 0 0 0

95.0° 0 0 0 0 0 0 0 0

100.0° 1 1 1 1 1 1 1 1

105.0° 1 1 1 1 1 1 1 1

110.0° 1 1 1 1 1 1 1 1

115.0° 1 1 1 1 1 1 1 1

120.0° 1 1 1 1 1 1 1 1

125.0° 2 2 2 2 2 2 2 2

130.0° 2 2 2 2 2 2 2 2

135.0° 2 2 2 2 2 2 2 2

140.0° 3 3 3 3 3 3 3 3

145.0° 3 3 3 3 3 3 3 3

150.0° 3 3 3 4 4 4 3 4

155.0° 4 4 4 4 4 4 4 4

160.0° 4 4 4 4 4 4 4 4

165.0° 4 4 4 4 4 4 4 4

170.0° 4 4 4 4 4 4 4 5

175.0° 5 5 5 5 5 4 5 5

180.0° 6 6 5 5 5 5 5 6

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China.

The NVLAP Lab Code is 200707-0

Page 14 of 15

Zonal Lumen Density Measurement

Deg Flux (lm) % Deg Flux (lm) %

0-5 125.7 0.89 0-5 125.7 0.89

5-10 374.9 2.65 0-10 500.6 3.54

10-15 615.7 4.36 0-15 1116.3 7.90

15-20 838.6 5.93 0-20 1954.8 13.83

20-25 1028.8 7.28 0-25 2983.7 21.11

25-30 1177.1 8.33 0-30 4160.8 29.44

30-35 1275.0 9.02 0-35 5435.8 38.46

35-40 1327.3 9.39 0-40 6763.1 47.85

40-45 1361.1 9.63 0-45 8124.2 57.48

45-50 1371.0 9.70 0-50 9495.1 67.18

50-55 1323.3 9.37 0-55 10818.5 76.55

55-60 1184.9 8.38 0-60 12003.3 84.93

60-65 960.6 6.80 0-65 12964.0 91.73

65-70 673.2 4.76 0-70 13637.2 96.49

70-75 357.0 2.53 0-75 13994.2 99.02

75-80 112.5 0.79 0-80 14106.7 99.81

80-85 11.6 0.08 0-85 14118.3 99.89

85-90 1.2 0.01 0-90 14119.5 99.90

90-95 0.3 0.01 0-95 14119.8 99.91

95-100 0.4 0.00 0-100 14120.2 99.91

100-105 0.5 0.00 0-105 14120.7 99.91

105-110 0.6 0.01 0-110 14121.3 99.92

110-115 0.7 0.00 0-115 14121.9 99.92

115-120 0.7 0.01 0-120 14122.6 99.93

120-125 0.8 0.00 0-125 14123.4 99.93

125-130 0.9 0.01 0-130 14124.2 99.94

130-135 1.0 0.00 0-135 14125.2 99.94

135-140 1.1 0.01 0-140 14126.3 99.95

140-145 1.2 0.01 0-145 14127.5 99.96

145-150 1.3 0.01 0-150 14128.8 99.97

150-155 1.2 0.01 0-155 14130.0 99.98

155-160 1.1 0.01 0-160 14131.1 99.99

160-165 0.9 0.00 0-165 14132.0 99.99

165-170 0.7 0.01 0-170 14132.7 100.00

170-175 0.4 0.00 0-175 14133.1 100.00

175-180 0.1 0.00 0-180 14133.2 100.00

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,

Futian Free Trade Zone, Shenzhen, Guangdong, China.

The NVLAP Lab Code is 200707-0

Page 15 of 15

[Additional Test]

Test Item Test Voltage (V) Frequency (Hz) Test Result

Total Harmonic Distortion: 230.0 50 7.44%

6. Product Photo

***********END OF REPORT***********