    STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp.

    (Shenzhen).The test data was only valid for the test sample(s). This report must notbe used by the customer to claim product certification,

    approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government.

    This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

    IES LM-79-08

    MEASUREMENT AND TEST REPORTFor

    ATG Electronics Corp

    9020 Rancho Park Court Rancho Cucamonga, CA 91730

    Test Model: HBCC20

    Report Type:Electrical and Photometric tests including: Luminous Flux,Color, Luminous Intensity Distribution, THD, Off-state

    Power

    Test Engineer: Daniel Duan

    Report Number: RSZ131022510-10

    Test Date: 2014-01-07

    Report Date: 2014-01-07

    Reviewed By: Jeanne Han/Safety Manager

    Prepared By:

    Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building,ShiHua Road, FuTian Free Trade ZoneShenzhen, Guangdong, China

    Tel: +86-755-33320018Fax: +86-755-33320008

    Test Facility: Test facility was located at Pu Long Cun 69, Puxinghu IndustrialArea, Tangxia Town, Dongguan, Guangdong, P.R.China.

    Accreditation: The NVLAP Lab Code is 200707-0.

  • 8/10/2019 HBCC20

    2/13

    Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ131022510-10 Page 2 of 13 The NVLAP Lab Code is 200707-0.

    1. Product Description

    General Information:

    Sample No.:RSZ131022510-S01 Model: HBCC20 One sample was received on 2013-10-22 and used for testing.

    Model Tested: HBCC20

    Manufacturer: ATG Electronics Corp

    Brand Name: ATG

    Product Designation: HighBay

    Burning Time Before Test: 0 hour(For New Products)

    Rated Values:

    Rated Voltage/Frequency: 100-277 VAC 50/60Hz

    Rated Power: 200W

    Nominal CCT: 5000K

    2. Standards Used

    IESNA LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products

    ANSI C82.77-2002: Harmonic Emission Limits Related Power Quality Requirements for Lighting

    3. Description of Test Equipment

    Device Manufacture Model No Serial No Test Range Calibration date

    1.5m temperature

    integrating sphereSENSING SPR-600 S09008 2550 2013-03-08

    Spectral radiation analyzer SENSING SPR3000 90902027 350nm800nm 2013-03-08

    Digital power meter YOKOGAWA WT-210 91j92613215/30/60/150/300/60

    0 V2013-03-25

    Precision frequency power

    supplyALL Power APW-105N 970613 0V-300V 50-400Hz 2013-03-25

    Standard Light Source SENSING N/A LSD090808 N/A 2013-05-13

    Temperature/humidity/clock Victor VC230 EE209 0~400~90% 2013-04-01

    Programmable Precision DC

    Power SupplyITECH IT6154

    0061 0417

    6471 0010 190~60V 2013-03-25

    AC POWER SUPPLY EVERFINE VPS1060 PWM 1101006 0-150V0-300V 2013-03-25

    Digital CC&CV DC Power

    SupplyEVERFINE WY12010 1009009 30V/5A 2013-03-25

    Electrical parameter tester YOKOGAWA WT-210 91KB35700

    15/30/60/150/300/60

    0 V 2013-03-25full-field speed

    goniophotometerEVERFINE GO-R5000

    YG108492N1

    01200011600mm,3000W/10A 2013-03-08

    Temperature/humidity/clock Victor VC230 EE091 0~400~90% 2013-04-01

    Standard Light Source EVERFINE D908 1012001 N/A 2013-05-28

    Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been

    performed using suitable standards traceable to National Primary Standards and International System of Units (SI).

  • 8/10/2019 HBCC20

    3/13

    Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ131022510-10 Page 3 of 13 The NVLAP Lab Code is 200707-0.

    4. Test Method

    Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of thesample was maintained at 25C1C during measurement. And relative humidity is less than 65%.

    Integrating Sphere System

    The system includes AC power source, digital power meter, DC power supply, spectrophotometer, and integratingsphere. The integrating sphere system is calibrated by standard light source before measurement.

    4geometry was used during measurement. The product was operated in its intended orientation in application andwas recorded in this report.

    The uncertainty of the light output (luminous flux) measurements is U=1.70% (K=2), at the 95% confidence level. Theuncertainty of the correlated color temperature measurements is U=21K (K=2), at the 95% confidence level. Theuncertainty of the CRI is U=1.4(K=2) , at the 95% confidence level.

    Goniophotometer System

    The goniophotometer system is calibrated by standard light source before measurement.

    Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatialuniformity. The product was operated in its intended orientation in application and was recorded in this report.

    The uncertainty of the luminous intensity is U=2.82% (K=2) , at the 95% confidence level.

    Additional Test

    The Additional Test item may not be covered by IESNA LM-79-2008. Additional test including power factor, off-statepower and THD, was measured by Digital Power Meter after stabilized at 25C1C.Test voltage for THD and powerfactor test would be equal to rated voltage or, in case of a voltage range, maximum value of that range.

  • 8/10/2019 HBCC20

    4/13

    Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ131022510-10 Page 4 of 13 The NVLAP Lab Code is 200707-0.

    5. Test Result

    [Integrating Sphere System]

    Total operating time for integrating sphere test:1.5 hours

    Test orientation:Downward

    Electrical Measurement

    Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor

    120.07 60.0 1.7251 206.33 0.996

    Photometric Measurement

    Luminous Flux (lm) Radiant Flux (W) Efficacy (lm/W) CCT (K) Duv

    18456.942 39.878 89.454 5292 4.02E-03

    Chromaticity Coordinate

    x y u v u' v'

    0.3378 0.3536 0.2057 0.3230 0.2057 0.4846

    Color Rendering Index

    Ra

    82.1

    R1 R2 R3 R4

    82 84 86 84

    R5 R6 R7 R8

    82 79 87 72

    R9 R10 R11 R12

    15 63 84 58

    R13 R14 R15

    83 92 77

  • 8/10/2019 HBCC20

    5/13

    Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ131022510-10 Page 5 of 13 The NVLAP Lab Code is 200707-0.

    Relative Spectral Power Distribution

    nm mW nm mW nm mW nm mW nm mW

    380 3.504E-02 465 5.834E-01 550 9.443E-01 635 6.168E-01 720 7.830E-02

    385 2.331E-02 470 4.116E-01 555 9.358E-01 640 5.684E-01 725 6.783E-02

    390 1.563E-02 475 3.090E-01 560 9.297E-01 645 5.187E-01 730 5.895E-02

    395 1.185E-02 480 2.836E-01 565 9.252E-01 650 4.731E-01 735 5.136E-02

    400 9.301E-03 485 3.036E-01 570 9.202E-01 655 4.300E-01 740 4.458E-02

    405 9.814E-03 490 3.612E-01 575 9.225E-01 660 3.862E-01 745 3.939E-02

    410 1.569E-02 495 4.503E-01 580 9.222E-01 665 3.474E-01 750 3.487E-02

    415 3.179E-02 500 5.635E-01 585 9.254E-01 670 3.056E-01 755 3.109E-02

    420 7.236E-02 505 6.696E-01 590 9.239E-01 675 2.706E-01 760 2.756E-02

    425 1.611E-01 510 7.770E-01 595 9.238E-01 680 2.383E-01 765 2.456E-02

    430 3.235E-01 515 8.555E-01 600 9.148E-01 685 2.070E-01 770 2.235E-02

    435 5.881E-01 520 9.204E-01 605 8.894E-01 690 1.817E-01 775 2.003E-02

    440 1.012E+00 525 9.564E-01 610 8.607E-01 695 1.570E-01 780 1.805E-02

    445 1.573E+00 530 9.722E-01 615 8.254E-01 700 1.361E-01 785 1.645E-02

    450 1.706E+00 535 9.687E-01 620 7.778E-01 705 1.181E-01 790 1.548E-02

    455 1.257E+00 540 9.717E-01 625 7.234E-01 710 1.033E-01 795 1.413E-02

    460 8.166E-01 545 9.551E-01 630 6.671E-01 715 8.976E-02 800 1.322E-02

    0.0

    0.2

    0.4

    0.6

    0.8

    1.0

    1.2

    380 440 500 560 620 680 740 800

  • 8/10/2019 HBCC20

    6/13

    Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ131022510-10 Page 6 of 13 The NVLAP Lab Code is 200707-0.

    CIE 1931 x y Chromaticity Diagram

    7-Step & 4-Step Chromaticity Quadrangles

    0

    0.1

    0.2

    0.3

    0.4

    0.5

    0.6

    0.7

    0.8

    0.9

    0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

    0.30

    0.35

    0.40

    0.45

    0.30 0.35 0.40 0.45 0.50

    sample

    7-STEP 2700K

    7-STEP 3000K

    7-STEP 3500K

    7-STEP 4000K

    7-STEP 4500K

    7-STEP 5000K

    7-STEP 5700K

    7-STEP 6500K

    4-STEP 2700K

    4-STEP 3000K4-STEP 3500K

    4-STEP 4000K

    4-STEP 5000K

    4-STEP 6500K

  • 8/10/2019 HBCC20

    7/13

    Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ131022510-10 Page 7 of 13 The NVLAP Lab Code is 200707-0.

    [Goniophotometer System]

    Total operating time for luminous intensity distribution:2.0 hours

    Test orientation:Downward

    Electrical Measurement

    Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor

    120.0 60.0 1.758 210.1 0.9954

    Photometric Measurement

    Luminous Flux (lm) Efficacy (lm/W) CBCP (cd) S/MH (C0/180) S/MH (C90/270)

    19107.5 90.95 17131 0.86 0.87

    Luminous Intensity Distribution

    C0/180 C45/225 C90/270 C135/315 AVG.

    Beam Angle (50% Imax): 58.4 56.1 58.7 56.6 57.5

    Field Angle (10% Imax): 97.9 88.8 98.3 88.2 93.3

  • 8/10/2019 HBCC20

    8/13

    Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ131022510-10 Page 8 of 13 The NVLAP Lab Code is 200707-0.

    Luminous Intensity (cd) Distribution Data

    C0 22.5 45 67.5 90 112.5 135 157.5

    0.0 17131 17131 17131 17131 17131 17131 17131 17131

    5.0 16127 16442 16969 16817 16598 16820 17008 16760

    10.0 15288 15670 18487 16199 15752 16041 18653 16229

    15.0 14302 14818 15142 14994 14568 15221 15911 15238

    20.0 13391 13008 12503 13469 13905 14836 14930 14825

    25.0 10234 10629 10768 10704 10452 11410 11777 11381

    30.0 7751 7706 7763 7878 7973 8448 8673 8679

    35.0 5773 5849 6147 6128 6770 6608 6442 6774

    40.0 4140 3904 2791 3946 4198 4035 3126 4160

    45.0 1852 1878 1768 1837 1844 1873 1745 1883

    50.0 1669 1730 1669 1697 1667 1713 1660 1787

    55.0 1275 1311 1292 1304 1277 1336 1317 1377

    60.0 1020 1011 931 1009 996 1030 966 1064

    65.0 776 807 739 771 768 791 748 84670.0 533 530 469 508 508 518 484 564

    75.0 338 325 281 303 298 297 288 338

    80.0 201 192 180 178 177 174 175 190

    85.0 151 149 131 133 129 132 130 142

    90.0 125 122 113 113 118 111 113 123

    95.0 90 84 97 91 88 88 89 83

    100.0 62 61 68 73 74 72 66 60

    105.0 60 56 56 57 59 56 53 53

    110.0 57 51 49 49 48 48 46 50

    115.0 48 42 45 45 43 43 43 40

    120.0 52 41 45 43 41 41 43 40125.0 49 39 45 42 41 41 43 36

    130.0 42 37 45 43 40 42 42 36

    135.0 42 40 44 42 38 41 42 38

    140.0 41 41 41 40 37 39 41 39

    145.0 41 38 37 37 35 36 36 36

    150.0 36 36 37 34 33 33 36 35

    155.0 34 34 39 35 31 34 40 33

    160.0 40 37 39 38 37 37 39 36

    165.0 36 35 37 37 37 33 37 34

    170.0 32 30 31 33 34 28 28 33

    175.0 22 21 23 25 25 20 21 25

    180.0 17 17 18 20 21 20 18 17

  • 8/10/2019 HBCC20

    9/13

    Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ131022510-10 Page 9 of 13 The NVLAP Lab Code is 200707-0.

    Luminous Intensity (cd) Distribution Data (cont.)

    C180 202.5 225 247.5 270 292.5 315 337.5

    0.0 17131 17131 17131 17131 17131 17131 17131 17131

    5.0 16519 16628 16760 16325 16159 16356 16474 16217

    10.0 15855 15994 18426 15465 15200 15562 18235 15658

    15.0 14721 15174 15074 14495 13958 14224 14496 14368

    20.0 14143 13994 13648 14133 13640 13258 13105 13357

    25.0 10837 10878 11162 10721 10551 10873 10772 10682

    30.0 8455 8384 8482 8486 8263 8160 8065 7923

    35.0 7069 6831 6474 6552 6607 6056 5692 5774

    40.0 4318 4114 3272 4143 4267 3683 2747 3411

    45.0 1953 1837 1668 1809 1901 1891 1744 1744

    50.0 1782 1755 1618 1727 1731 1729 1663 1621

    55.0 1366 1385 1337 1324 1363 1330 1253 1255

    60.0 1095 1077 998 1056 1107 1075 972 1006

    65.0 864 852 778 811 838 867 770 82070.0 589 572 515 549 573 588 495 516

    75.0 363 341 308 329 357 348 314 315

    80.0 209 194 189 203 215 217 207 198

    85.0 143 148 144 153 154 164 147 159

    90.0 128 131 125 125 133 126 123 119

    95.0 86 85 96 100 101 99 100 89

    100.0 64 66 73 79 81 78 72 62

    105.0 58 55 58 62 63 61 56 56

    110.0 56 51 50 52 53 51 50 52

    115.0 47 40 44 47 47 47 44 42

    120.0 51 40 45 45 44 45 45 41125.0 49 39 45 45 44 44 46 39

    130.0 42 38 46 47 44 47 48 38

    135.0 42 40 46 46 43 45 47 44

    140.0 36 42 43 44 40 42 44 43

    145.0 39 38 38 40 37 39 38 39

    150.0 33 36 40 35 35 35 40 37

    155.0 32 33 43 37 31 36 43 34

    160.0 36 36 43 40 40 41 41 37

    165.0 36 33 39 35 39 38 38 34

    170.0 37 32 29 30 35 33 31 30

    175.0 24 24 21 19 23 24 23 21

    180.0 17 17 18 20 21 20 18 17

  • 8/10/2019 HBCC20

    10/13

    Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ131022510-10 Page 10 of 13 The NVLAP Lab Code is 200707-0.

    Average Area Illumination Figure

    Height (m)Diameter

    (cm)Eavg(lx) Emax(lx)

    0.5 54.9 42835.0 71493.0

    1.0 109.7 10709.0 17873.0

    1.5 164.6 4759.0 7944.0

    2.0 219.4 2677.0 4468.0

    2.5 274.3 1713.0 2860.0

    3.0 329.2 1190.0 1986.0

    3.5 384.0 874.2 1459.0

    4.0 438.9 669.3 1117.0

    4.5 493.8 528.8 882.6

    5.0 548.6 428.3 714.9

    Angle: 57.5 . Flux out: 10337.0 lm.

  • 8/10/2019 HBCC20

    11/13

    Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ131022510-10 Page 11 of 13 The NVLAP Lab Code is 200707-0.

    Zonal Lumen Density Measurement

    Deg Flux (lm) % Deg Flux (lm) %

    0-5 401.2 2.10 0-5 401.2 2.10

    5-10 1174.8 6.15 0-10 1576.0 8.25

    10-15 1851.5 9.69 0-15 3427.5 17.94

    15-20 2383.0 12.47 0-20 5810.5 30.41

    20-25 2542.9 13.31 0-25 8353.4 43.72

    25-30 2442.9 12.78 0-30 10796.3 56.50

    30-35 2152.0 11.27 0-35 12948.3 67.77

    35-40 1616.0 8.45 0-40 14564.2 76.22

    40-45 1003.6 5.25 0-45 15567.9 81.47

    45-50 711.5 3.73 0-50 16279.3 85.20

    50-55 662.8 3.47 0-55 16942.2 88.67

    55-60 535.5 2.80 0-60 17477.7 91.47

    60-65 445.4 2.33 0-65 17923.0 93.80

    65-70 338.3 1.77 0-70 18261.3 95.57

    70-75 218.1 1.14 0-75 18479.4 96.71

    75-80 132.5 0.70 0-80 18611.9 97.41

    80-85 89.6 0.47 0-85 18701.6 97.88

    85-90 73.0 0.38 0-90 18774.6 98.26

    90-95 58.3 0.30 0-95 18832.9 98.56

    95-100 43.1 0.23 0-100 18876.0 98.79

    100-105 33.7 0.17 0-105 18909.7 98.96

    105-110 28.2 0.15 0-110 18937.9 99.11

    110-115 23.8 0.13 0-115 18961.7 99.24

    115-120 21.5 0.11 0-120 18983.2 99.35

    120-125 20.0 0.10 0-125 19003.2 99.45

    125-130 18.5 0.10 0-130 19021.7 99.55

    130-135 17.2 0.09 0-135 19038.9 99.64

    135-140 15.4 0.08 0-140 19054.4 99.72

    140-145 13.1 0.07 0-145 19067.5 99.79

    145-150 10.7 0.06 0-150 19078.2 99.85

    150-155 9.0 0.04 0-155 19087.2 99.89

    155-160 7.6 0.04 0-160 19094.8 99.93

    160-165 6.2 0.04 0-165 19101.1 99.97

    165-170 4.1 0.02 0-170 19105.1 99.99

    170-175 2.0 0.01 0-175 19107.1 100.00

    175-180 0.5 0.00 0-180 19107.6 100.00

  • 8/10/2019 HBCC20

    12/13

    Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ131022510-10 Page 12 of 13 The NVLAP Lab Code is 200707-0.

    [Additional Test]

    Test Item Test Voltage (V) Frequency (Hz) Test Result

    Power Factor: 277 60 0.9214

    Total Harmonic Distortion: 120 60 4.87%

    Total Harmonic Distortion: 277 60 14.04%

    Off State Power: 120 60 0.0W

    6. Product Photo

  • 8/10/2019 HBCC20

    13/13

    Bay Area Compliance Laboratories Corp. (Shenzhen)6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ131022510-10 Page 13 of 13 The NVLAP Lab Code is 200707-0.

    ***********END OF REPORT***********